L-2015-303, Technical Specification Correction for License Amendment Request to Standardize the Required Actions for Inoperability of Auxiliary Feedwater Pumps

From kanterella
(Redirected from ML16005A147)
Jump to navigation Jump to search

Technical Specification Correction for License Amendment Request to Standardize the Required Actions for Inoperability of Auxiliary Feedwater Pumps
ML16005A147
Person / Time
Site: Saint Lucie  
Issue date: 12/15/2015
From: Costanzo C
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2015-303
Download: ML16005A147 (7)


Text

0December 15, 2015 L-2015-303 FPL/

10 CFR 50.90 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 TS Correction for License Amendment Request to Standardize the Required Actions for Inoperability of Auxiliary Feedwater Pumps

References:

1.

FPL Letter L-2015-079 dated July 15, 2015, "License Amendment Request to Standardize the Required Actions for Inoperability of Auxiliary Feedwater Pumps,"

ADAMS Accession No. ML15198A028

2.

NRC letter November 23, 2015, "Request for Additional Information RE: License Amendment Request for Changes to the Required Actions for Inoperability of Auxiliary Feedwater Pumps (CAC Nos. MF6491 and MF6492)," ADAMS Accession No. ML15308A615 In Reference 1 Florida Power & Light (FPL) submitted a Technical Specification (TS) amendment request that would standardize the TS LCO actions for inoperable auxiliary feedwater pumps.

Reference 2 identified an administrative oversight within the proposed TS surveillance requirements. The corrected TS markups and TSs supersede those in References 1 above and are provided in the attachment.

The no significant hazards consideration determination within Reference 1 bounds the scope of these changes. If you should have any questions, please contact Mr. Ken Frehafer at (772) 467-7748.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on December 1 5f

, 2015.

Sincerely, Christopher R. Costanzo Site Vice President St. Lucie Plant CRC/KWF Attachment cc:

NRC Region II Administrator St. Lucie Plant NRC Senior Resident Inspector l

X Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

L-2015-303 Attachment Page 1 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two motor driven feedwater pumps, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2 and 3.

ithe pump ACTION:

a.

With one auxiliary feedwater pump inoperable, restore a-es-he beiP, pewefed -by-an-PR-BEztz splyzstem-to OPERABLE status

[*

within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

-b.

LO 3.0.4.b is not applicable.

"--Insert II SURVEILLANCE REQUIREMENTS 4.7.1.2 Each auxiliary feedwater pump shall be demonstrated OPERABLE:

a.

In accordance with the Surveillance Frequency Control Program by:

A4/

ST. LUCIE - UNIT 13/7-3/4 7-4 Amendment No. 25. 99,4998,229, 23-

L-2015-303 Attachment Page 2 of 6 INSERT 1

b. With two auxiliary feedwater pumps inoperable, immediately enter LCO 3.0.3.

~NOTE LCO 3.0.3 and all other LCO Actions requiring MODE changes are suspended until one AFW pump is restored to OPERABLE status.

c. With three auxiliary feedwater pumps inoperable, immediately initiate corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

L-2015-303 Attachment.

Page 3 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two feedwater pumps, each capable of being powered from separate OPERABLE emergency busses, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2, and 3.

ACTION:

a.

With one auxiliary feedwater pump inoperable, restore the required auxiliary feedwater pumps to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With two auxiliary feedwater pumps inoperable be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

c* With three auxiliary feedwater pumps inoperable, immediately initiate

\\corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

d.
  • CO 3.0.4.b is not applicable.
a.

In ac rdance with the Surveillance Frequency Control Program by:

m-in t e flow path that is not locked, sealed, or otherwise secured in p ston,.is in its correct position.

ST. LUCIE - UNIT 2 3/4 7-4 Amendment No. 25,446, 4-740, 47~--

L-2015-303 Attachment Page 4 of 6 INSERT 2 NOTE LCO 3,0.3 and all other [CO Actions requiring MODE changes are suspended until one AFW pump is restored to OPERABLE status.

L-2015-303 Attachment Page 5 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two motor driven feedwater pumps, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2 and 3.

ACTION:

a.

With one auxiliary feedwater pump inoperable, restore the auxiliary feedwater pump to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With two auxiliary feedwater pumps inoperable, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

NOTE LCO 3.0.3 and all other LCO Actions requiring MODE changes are suspended until Sone AFW pump is restored to OPERABLE status.

c.

With three auxiliary feedwater pumps inoperable, immediately initiate corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

d.

LCO 3.0.4.b is not applicable.

SURVEILLANCE REOUIREMENTS 4.7.1.2 Each auxiliary feedwater pump shall be demonstrated OPERABLE:

a.

In accordance with the Surveillance Frequency Control Program by:

ST. LUCIE - UNIT 1 3!4 7-4 Amendment No. 35, 90, 4-9-9, 2-29,

L-201 5-3 03 Attachment Page 6 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two feedwater pumps, each capable of being powered from separate OPERABLE emergency busses, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2, and 3.

ACTION:

a.

With one auxiliary feedwater pump inoperable, restore the auxiliary feedwater pump to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With two auxiliary feedwater pumps inoperable, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

~NOTE LCO 3.0.3 and all other LCO Actions requiring MODE changes are suspended until one AFW pump is restored to OPERABLE status.

c.

With three auxiliary feedwater pumps inoperable, immediately initiate corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

d.

LCO 3.0.4.b is not applicable.

SURVEILLANCE REOUIREMENTS 4.7.1.2 Each auxiliary feedwater pump shall be demonstrated OPERABLE:

a.

In accordance with the Surveillance Frequency Control Program by:

t.

Verifying that each valve (manual, power-operated, or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

ST. LUCIE - UNIT 2 3/4 7-4 ST.LUCE

-UNI 2 14 -4Amendment No. 2-5, 44, -t-7-,

0December 15, 2015 L-2015-303 FPL/

10 CFR 50.90 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 TS Correction for License Amendment Request to Standardize the Required Actions for Inoperability of Auxiliary Feedwater Pumps

References:

1.

FPL Letter L-2015-079 dated July 15, 2015, "License Amendment Request to Standardize the Required Actions for Inoperability of Auxiliary Feedwater Pumps,"

ADAMS Accession No. ML15198A028

2.

NRC letter November 23, 2015, "Request for Additional Information RE: License Amendment Request for Changes to the Required Actions for Inoperability of Auxiliary Feedwater Pumps (CAC Nos. MF6491 and MF6492)," ADAMS Accession No. ML15308A615 In Reference 1 Florida Power & Light (FPL) submitted a Technical Specification (TS) amendment request that would standardize the TS LCO actions for inoperable auxiliary feedwater pumps.

Reference 2 identified an administrative oversight within the proposed TS surveillance requirements. The corrected TS markups and TSs supersede those in References 1 above and are provided in the attachment.

The no significant hazards consideration determination within Reference 1 bounds the scope of these changes. If you should have any questions, please contact Mr. Ken Frehafer at (772) 467-7748.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on December 1 5f

, 2015.

Sincerely, Christopher R. Costanzo Site Vice President St. Lucie Plant CRC/KWF Attachment cc:

NRC Region II Administrator St. Lucie Plant NRC Senior Resident Inspector l

X Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

L-2015-303 Attachment Page 1 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two motor driven feedwater pumps, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2 and 3.

ithe pump ACTION:

a.

With one auxiliary feedwater pump inoperable, restore a-es-he beiP, pewefed -by-an-PR-BEztz splyzstem-to OPERABLE status

[*

within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

-b.

LO 3.0.4.b is not applicable.

"--Insert II SURVEILLANCE REQUIREMENTS 4.7.1.2 Each auxiliary feedwater pump shall be demonstrated OPERABLE:

a.

In accordance with the Surveillance Frequency Control Program by:

A4/

ST. LUCIE - UNIT 13/7-3/4 7-4 Amendment No. 25. 99,4998,229, 23-

L-2015-303 Attachment Page 2 of 6 INSERT 1

b. With two auxiliary feedwater pumps inoperable, immediately enter LCO 3.0.3.

~NOTE LCO 3.0.3 and all other LCO Actions requiring MODE changes are suspended until one AFW pump is restored to OPERABLE status.

c. With three auxiliary feedwater pumps inoperable, immediately initiate corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

L-2015-303 Attachment.

Page 3 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two feedwater pumps, each capable of being powered from separate OPERABLE emergency busses, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2, and 3.

ACTION:

a.

With one auxiliary feedwater pump inoperable, restore the required auxiliary feedwater pumps to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With two auxiliary feedwater pumps inoperable be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

c* With three auxiliary feedwater pumps inoperable, immediately initiate

\\corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

d.
  • CO 3.0.4.b is not applicable.
a.

In ac rdance with the Surveillance Frequency Control Program by:

m-in t e flow path that is not locked, sealed, or otherwise secured in p ston,.is in its correct position.

ST. LUCIE - UNIT 2 3/4 7-4 Amendment No. 25,446, 4-740, 47~--

L-2015-303 Attachment Page 4 of 6 INSERT 2 NOTE LCO 3,0.3 and all other [CO Actions requiring MODE changes are suspended until one AFW pump is restored to OPERABLE status.

L-2015-303 Attachment Page 5 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two motor driven feedwater pumps, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2 and 3.

ACTION:

a.

With one auxiliary feedwater pump inoperable, restore the auxiliary feedwater pump to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With two auxiliary feedwater pumps inoperable, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

NOTE LCO 3.0.3 and all other LCO Actions requiring MODE changes are suspended until Sone AFW pump is restored to OPERABLE status.

c.

With three auxiliary feedwater pumps inoperable, immediately initiate corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

d.

LCO 3.0.4.b is not applicable.

SURVEILLANCE REOUIREMENTS 4.7.1.2 Each auxiliary feedwater pump shall be demonstrated OPERABLE:

a.

In accordance with the Surveillance Frequency Control Program by:

ST. LUCIE - UNIT 1 3!4 7-4 Amendment No. 35, 90, 4-9-9, 2-29,

L-201 5-3 03 Attachment Page 6 of 6 PLANT SYSTEMS AUXILIARY FEEDWATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.1.2 At least three independent steam generator auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a.

Two feedwater pumps, each capable of being powered from separate OPERABLE emergency busses, and

b.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

APPLICABILITY: MODES 1, 2, and 3.

ACTION:

a.

With one auxiliary feedwater pump inoperable, restore the auxiliary feedwater pump to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With two auxiliary feedwater pumps inoperable, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

~NOTE LCO 3.0.3 and all other LCO Actions requiring MODE changes are suspended until one AFW pump is restored to OPERABLE status.

c.

With three auxiliary feedwater pumps inoperable, immediately initiate corrective action to restore at least one auxiliary feedwater pump to OPERABLE status.

d.

LCO 3.0.4.b is not applicable.

SURVEILLANCE REOUIREMENTS 4.7.1.2 Each auxiliary feedwater pump shall be demonstrated OPERABLE:

a.

In accordance with the Surveillance Frequency Control Program by:

t.

Verifying that each valve (manual, power-operated, or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

ST. LUCIE - UNIT 2 3/4 7-4 ST.LUCE

-UNI 2 14 -4Amendment No. 2-5, 44, -t-7-,