NRC-036 Submitted Nov. 10, 2015 Prepared in cooperation with Miami-Dade County Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater in Miami-Dade County, Florida Well field Sewage Cl/Br ratio = 300 to 800 Freshwater Biscayne Aquifer Limestone CaCO 3 Infiltration
+ + from tidal Quartz Sand SiO 2 Little or no ion exchange marshes seaward of the ion Freshwater exchange front inflow Freshwater/saltwater interface Ion exchange Leading edge front of saltwater Encroachment NaCl, B, Br, Leakage from front ete d from ocean K, Li, SO 4 D ep l Residual unprotected Mg along the base HC O 3 SO4 saltwater canals Ca Li K B
i ve of the aquifer va t Na o n ser Saltwater hed r=C E n r ic C l , B Pinecrest sand member Quartz sand SiO 2 Scientific Investigations Report 2014-5025 U.S. Department of the Interior U.S. Geological Survey
Cover. Conceptual diagram of sources and mechanisms of the saltwater that has intruded parts of aquifers in southeast Florida, and changes in water chemistry that may result from this intrusion.
Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater in Miami-Dade County, Florida By Scott T. Prinos, Michael A. Wacker, Kevin J. Cunningham, and David V. Fitterman Prepared in cooperation with Miami-Dade County Scientific Investigations Report 2014-5025 U.S. Department of the Interior U.S. Geological Survey
U.S. Department of the Interior SALLY JEWELL, Secretary U.S. Geological Survey Suzette M. Kimball, Acting Director U.S. Geological Survey, Reston, Virginia: 2014 For more information on the USGSthe Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment, visit http://www.usgs.gov or call 1-888-ASK-USGS.
For an overview of USGS information products, including maps, imagery, and publications, visit http://www.usgs.gov/pubprod To order this and other USGS information products, visit http://store.usgs.gov Any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government.
Although this information product, for the most part, is in the public domain, it also may contain copyrighted materials as noted in the text. Permission to reproduce copyrighted items must be secured from the copyright owner.
Suggested citation:
Prinos, S.T., Wacker, M.A., Cunningham, K.J., and Fitterman, D.V., 2014, Origins and delineation of saltwater intrusion in the Biscayne aquifer and changes in the distribution of saltwater in Miami-Dade County, Florida: U.S. Geological Survey Scientific Investigations Report 2014-5025, 101 p., http://dx.doi.org/10.3133/sir20145025.
ISSN 2328-0328 (online)
iii Acknowledgments The authors would like to acknowledge the contributions of information provided by EAS Engineering, Inc., the Florida Department of Environmental Protection, the Florida Keys Aqueduct Authority, Miami-Dade County Department of Environmental Resource Manage-ment, and the South Florida Water Management District. We greatly appreciate the cooperation of the following property owners who allowed us to make measurements on their lands: the AA Baker Group, LTD, the Archdiocese of Miami, Alamo Rent A Car, Barry University, FRS Hold-ings, Inc., the City of Homestead, Homestead Miami Speedway, Hallandale Beach Elementary School, the Miami-Dade County Department of Public Schools, Miami-Dade County Parks and Recreation Department, the South Florida Water Management District, and Palmer Trinity School. Bob Brown of the Archdiocese of Miami; Edward Swakon of EAS Engineering, Inc.;
Dr. Claudius Carnegie, Jorge Corrales, and Greg Mohr of the Miami-Dade County Department of Public Schools; Maria Idia Macfarlane, Sonia Villamil, and Virginia Walsh of the Miami-Dade Water and Sewer Department; and Steve Krupa of the South Florida Water Management District were instrumental in helping us gain access to numerous properties where the time-domain electromagnetic soundings were completed. Maria Idia Macfarlane of the Miami-Dade County Water and Sewer Department helped to oversee much of the well installation. Jorge Corrales helped collect many of the surface geophysical measurements that were made on lands owned by the Miami-Dade County Department of Public Schools. Michael J. Alexander, proj-ect manager of the Homestead Miami Speedway, not only provided necessary access to speed-way properties for measurements but also helped make necessary contacts with other properties owners in the area. Jim Happell of the University of Miami, Rosenstiel School of Marine and Atmospheric Science, John Stowell of Mount Sopris Instrument Company, and Roy Sonenshein of the National Park Service, Everglades National Park provided substantive reviews.
The authors also would like to acknowledge the contributions of staff members of the U.S. Geological Survey. Michele Markovits helped with many aspects of this study, including the geochemical sampling, geophysical data collection, data entry, and sample preparation and analysis. Adam Foster provided substantive geochemical advice and helped to compile sample results in the database. Robert Valderrama completed most of the processing of time series elec-tromagnetic induction log sets, and Brian Banks collected the most recent logs for these data-sets. Ronald Bruce Irvin provided quality assurance of these log sets and partially automated the application of necessary adjustments. Lee Massey and Corey Whittaker helped to collect water samples. Brian Banks, Adrian Castillo, Eric Carlson, and Jeff Robinson helped to collect time-domain electromagnetic soundings. Jeff Robinson also collected many of the borehole logs as the new monitoring wells were being installed and helped to oversee some of the well installation. Ronald Bruce Irvin created the necessary scripts, software, and files to convert the static Manual Water-Level Measurements in South Florida website into a dynamic website that serves routinely collected salinity information as well as most of the salinity information collected during this study. The new website has proven to be valuable to local water manag-ers as they seek greater understanding of the changes in the extent and magnitude of saltwater intrusion in the Biscayne aquifer. Ronald Bruce Irvin also oversaw quality assurance for the time-series electromagnetic induction logs used during this study. Michael W. Bradley, Ed Busenberg, Richard H. Coupe, Kim H. Haag, Steven Hinkle, Carole Johnson, Robert Renken, Dorothy Sifuentes, Rick M. Spechler, David Sumner, Kimberly A. Swidarski, Kim Walten-baugh, and Peggy Widman provided invaluable support during the review, approval, and publi-cation process of this report.
iv Contents Abstract............................................................................................................................................................1 Introduction.....................................................................................................................................................2 Definition of Terms.................................................................................................................................2 Purpose and Scope...............................................................................................................................6 Approach.................................................................................................................................................6 Description of Study Area....................................................................................................................6 Hydrologic Controls......................................................................................................................6 Topography and Physiography...................................................................................................7 Climate............................................................................................................................................7 Water Use in Miami-Dade County.............................................................................................7 Hydrogeology/Hydrostratigraphic Framework......................................................................10 Previous Studies..................................................................................................................................11 Origin of Saltwater Intrusion in Southeastern Florida............................................................................12 Mechanisms of Saltwater Intrusion.................................................................................................12 Upconing of Relict Saltwater from Previous Sea-Level High Stands................................12 Encroachment of Seawater along the Base of the Biscayne Aquifer...............................13 Infiltration of Saltwater from Saltwater Marshes.................................................................13 Seepage from Streams or Canals in which Saltwater has Migrated Inland....................13 Effects of Urban and Hydrologic Development on Saltwater Intrusion.....................................16 Predevelopment Conditions......................................................................................................17 Relation of Urban Development to Saltwater Intrusion.......................................................17 Data Collection and Analysis......................................................................................................................20 Salinity Measurements.......................................................................................................................21 Time-Series Electromagnetic Induction Logging...........................................................................21 Comparison of Bulk Resistivity to Specific Conductance of Water and Chloride Concentration.........................................................................................................................22 Time-Domain Electromagnetic Soundings......................................................................................22 HEM Survey Analysis..........................................................................................................................22 Approximate Inland Extent of Saltwater in the Biscayne Aquifer........................................................25 Improved Spatial Coverage and Precision of the Inland Extent of Saltwater...........................25 Changes between 1995 and 2011......................................................................................................25 Characterization and Distribution of Saltwater in the Biscayne Aquifer ...........................................28 Major and Trace Ion Geochemistry..................................................................................................28 Strontium Isotope Age Dating...........................................................................................................34 Oxygen and Hydrogen Stable Isotopes............................................................................................35 Tritium and Uranium Concentration..................................................................................................38 Tritium/Helium-3 Age Dating..............................................................................................................38 Sulfur Hexafluoride Age Dating.........................................................................................................39 Estimates of Recharge Temperature Based on Dissolved Gases...............................................39 Sources of Saltwater in the Biscayne Aquifer........................................................................................41 Relict Seawater from Previous Sea-Level High Stands................................................................41 Historical Leakage of Saltwater from Canals.................................................................................42 The Card Sound Road Canal and FEC Railway Borrow Ditches.........................................43
v Miami and Tamiami Canals.......................................................................................................47 C-111 Canal.................................................................................................................................47 Turkey Point Nuclear Power Plant Cooling Canal System...................................................47 Recent Leakage from Canals.............................................................................................................47 Card Sound Road Canal.............................................................................................................48 Biscayne Canal...........................................................................................................................48 Snapper Creek Canal.................................................................................................................49 Black Creek Canal......................................................................................................................51 Princeton Canal...........................................................................................................................54 Saltwater Encroachment....................................................................................................................55 Limitations......................................................................................................................................................56 Summary and Conclusions..........................................................................................................................64 Selected References....................................................................................................................................66 Appendix 1. Site Location and Construction Information.................................................................76 Appendix 2. Results of Geochemical Sampling..................................................................................76 Appendix 3. Salinity Profiles Collected from the Card Sound Road Canal....................................76 Appendix 4. Results of Time-Domain Electromagnetic Soundings.................................................76 Appendix 5. Time-Series Electromagnetic Induction Log (TSEMIL) Dataset Calibration and Processing.............................................................................................77 Appendix 6. Evaluation of Depth of the Biscayne Aquifer by Using TEM Soundings..................83 Appendix 7. Description of Installation and Construction of Saltwater Front Monitoring Wells...............................................................................................................88 Appendix 8. Geophysical Logs .............................................................................................................94 Appendix 9. Hydrostratigraphic Analysis............................................................................................94 Appendix 10. Geochemical Sampling Methods...................................................................................96 Appendix 11. Salinity Measurements in Canals ................................................................................101 Appendix 12. Geographic Information System Files..........................................................................101 Figures
- 1. Map showing the location of the study area, well fields, the National Parks, water conservation areas, and the helicopter electromagnetic survey of 2001, Miami-Dade and Broward Counties, Florida.............................................................................3
- 2. Map created for the Annual Report of the Surveyor General for 1859, New York, NY, General Land Office, 1859, courtesy of the Geography and Map Division of the Library of Congress.............................................................................................4
- 3. Map showing the physiographic provinces, location of the cross section shown in figure 7, and locations of rainfall monitoring stations within the study area.......................................................................................................................................8
- 4. Graph showing estimated total annual precipitation from selected stations in or near Miami-Dade County and documented droughts during 1931 to 2011.....................9
- 5. Graph showing estimated population (from U.S. Census Bureau, 2013) and public groundwater withdrawals in Miami-Dade County, Florida.........................................9
- 6. Chart showing the generalized relation of hydrogeologic, lithostratigraphic, and time-stratigraphic units in Miami-Dade County..............................................................10
- 7. Hydrogeologic section A-A showing hydrostratigraphy of the surficial aquifer system and uppermost part of the intermediate confining unit from west to east across central Miami-Dade County.................................................................................11
vi
- 8. Map showing the locations of salinity monitoring sites, time-domain electromagnetic soundings, groundwater-level monitoring wells, and the mapped approximations of the inland extent of saltwater in the Biscayne aquifer in Miami-Dade and southern Broward Counties......................................................15
- 9. Conceptual diagram of sources and mechanisms of the saltwater that has intruded parts of aquifers in southeast Florida, and changes in water chemistry that may result from this intrusion.........................................................................16
- 10. Graph showing salinity of the Biscayne Canal at station BS04, Miami-Dade County, Florida, 1988-2010..........................................................................................................17
- 11. Photograph showing the rapids of the Miami River prior to their destruction by dynamiting to increase drainage of the Everglades..............................................................19
- 12. Photograph showing the first water control structure on the Miami Canal installed in December 1939........................................................................................................19
- 13. Graph showing chloride concentration in samples from monitoring wells G-355, G-548, G-1351, and G-1354 near the Miami Canal and between 0.6 and 2.4 kilometers northwest of salinity control structure S-26, Miami-Dade County, Florida............................................................................................................................................20
- 14. Graph showing the relation between the resistivity of water samples collected in monitoring wells in Miami-Dade County, Florida, and the formation resistivity measured by electromagnetic induction logs in the screened intervals of the same well......................................................................................................................................23
- 15. Graph showing the relation between water resistivity and chloride concentration in water samples from monitoring wells in Miami-Dade County, Florida..........................23
- 16. Example of a depth slice from the 2001 helicopter electromagnetic survey, Miami-Dade County, Florida.......................................................................................................24
- 17. Map showing the origin and delineation of saltwater intrusion in the Biscayne aquifer and the basis for modifications to its mapped extent..............................................26
- 18. Graphs showing chloride concentrations in water samples from long-term monitoring wells...........................................................................................................................27
- 19. Graph showing the calcium to (bicarbonate + sulfate) ratio and the chloride concentration in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..................................................................................30
- 20. Graph showing the bromide and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................30
- 21. Graph showing the magnesium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida............................................................................................................................................31
- 22. Graph showing the potassium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................31
- 23. Graph showing the sodium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................32
- 24. Graph showing the boron and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................32
- 25. Graph showing the sulfate and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................33
vii
- 26. Graph showing the calcium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................33
- 27. Graph showing the barium and chloride concentrations in samples.................................34
- 28. Graph showing the silica and chloride concentrations in samples....................................35
- 29. Graphs showing relations between (A) chloride concentration and delta deuterium and (B) delta oxygen-18 and delta deuterium in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................37
- 30. Graph showing the 3H/3He interpreted piston-flow ages of water samples collected during 2009-2010 in the Miami-Dade County area and dates of documented droughts in south Florida....................................................................................41
- 31. Graphs showing the (A) average monthly precipitation, daily average air temperature in Miami, Florida, and the range of recharge temperatures of water samples collected from the Biscayne aquifer in Miami-Dade County, Florida, and (B) average of daily maximum water levels in selected wells open to the Biscayne aquifer during October 1, 1974, to September 30, 2009..................44
- 32. Graphs showing (A) time-series electromagnetic induction log (TSEMIL) dataset and (B) chloride concentrations in samples from monitoring well G-3601 and bulk conductivity measured at a depth of 56.1 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................45
- 33. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3701 and bulk conductivity measured at a depth of 24.0 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................46
- 34. Graph showing salinity of the Snapper Creek Canal at station SP04, 1991-2010, Miami-Dade County, Florida..................................................................................49
- 35. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples collected from well G-3608 and bulk conductivity measured at a depth of 28.9 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................50
- 36. Graph showing chloride concentrations in water samples from wells G-896 and G-3608, Miami-Dade County, Florida................................................................................52
- 37. Graph showing water levels in wells G-896 and G-3608, 1996-2011, Miami-Dade County, Florida.......................................................................................................52
- 38. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from well G-3702 and bulk conductivity measured at a depth of 24.6 meters, Biscayne aquifer, Miami-Dade County, Florida.......................................................................................................53
- 39. Graph showing salinity of the Black Creek Canal at station BL03, 1991-2008 and 2010, Miami-Dade County, Florida.....................................................................................54
- 40. Graph showing salinity of the Princeton Canal at station PR03, 1991-2008 and 2010, Miami-Dade County, Florida.....................................................................................55
- 41. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3604 and bulk conductivity measured at a depth of 34.7 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................57
- 42. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3609 and bulk conductivity measured at a depth of 22.7 meters, Biscayne aquifer, Miami-Dade County, Florida......................................................................58
viii
- 43. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3698 and bulk conductivity measured at a depth of 24.5 meters, Biscayne aquifer, Miami-Dade County, Florida......................................................................59
- 44. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3699 and bulk conductivity measured at a depth of 25.3 meters, Biscayne aquifer, Miami-Dade County, Florida......................................................................60
- 45. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3602 and bulk conductivity measured at a depth of 46.9 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................61
- 46. Graphs showing time-series electromagnetic induction log (TSEMIL) datasets from monitoring wells (A) G-3855 and (B) G-3856 for November 2007 to April 2008, Biscayne aquifer, Miami-Dade County, Florida...................................................62
- 47. Graphs showing chloride concentrations in samples from monitoring wells, Miami-Dade County, Florida.......................................................................................................63
- 48. Graph showing salinity of the Mowry Canal at station MW04, 1991-2009 and 2010, Miami-Dade County, Florida.....................................................................................63 Tables
- 1. Partial history (1881-1978) of canal, structure, and levee installations in south Florida.................................................................................................................................18
- 2. Partial history (1899-2001) of well field installations and operations in Miami-Dade County, Florida.......................................................................................................19
- 3. Vertical flows measured in open boreholes prior to well installation, 2009-2011, Miami-Dade County, Florida..................................................................................21
- 4. Determination of the strontium-87 to strontium-86 ratio in water samples collected during 2009, in Miami-Dade County, Florida..........................................................36
- 5. Results of tritium/helium-3 age dating of water samples collected during 2009-2010 in Miami-Dade County, Florida...............................................................................40
- 6. Differences between ages determined using SF6 and tritium/helium-3 age dating for samples collected in Miami-Dade County, Florida, during 2009-2010.............42
- 7. Average recharge temperature and chloride concentration of surface-water and groundwater samples collected in Miami-Dade County, Florida during 2009-2010......................................................................................................................................43
ix Conversion Factors SI to Inch/Pound Multiply By To obtain Length centimeter (cm) 0.3937 inch (in.)
millimeter (mm) 0.03937 inch (in.)
meter (m) 3.281 foot (ft) kilometer (km) 0.6214 mile (mi)
Area square meter (m2) 0.0002471 acre square kilometer (km ) 2 247.1 acre square centimeter (cm2) 0.001076 square foot (ft2) square meter (m2) 10.76 square foot (ft2) square centimeter (cm2) 0.1550 square inch (ft2) square kilometer (km ) 2 0.3861 square mile (mi2)
Volume liter (L) 0.2642 gallon (gal) cubic meter (m )3 264.2 gallon (gal) cubic meter (m3) 0.0002642 million gallons (Mgal) cubic centimeter (cm ) 3 0.06102 cubic inch (in3) liter (L) 61.02 cubic inch (in3) cubic meter (m )3 35.31 cubic foot (ft3)
Flow rate meter per day (m/d) 3.281 foot per day (ft/d) meter per year (m/yr) 3.281 foot per year ft/yr) liter per second (L/s) 15.85 gallon per minute (gal/min) liter per minute (L/min) 0.2642 gallon per minute (gal/min) cubic meter per day (m3/d) 264.2 gallon per day (gal/d) cubic meter per second (m /s) 3 22.83 million gallons per day (Mgal/d)
Mass gram (g) 0.03527 ounce, avoirdupois (oz) kilogram (kg) 2.205 pound avoirdupois (lb)
Radioactivity becquerel per liter (Bq/L) 27.027 picocurie per liter (pCi/L)
Hydraulic conductivity meter per day (m/d) 3.281 foot per day (ft/d)
Hydraulic gradient meter per kilometer (m/km) 5.27983 foot per mile (ft/mi)
Transmissivity*
meter squared per day (m2/d) 10.76 foot squared per day (ft2/d)
x Electrical Conductivity and Electrical Resistivity Multiply By To obtain Electrical conductivity siemens per meter (S/m) 1,000 millisiemens per meter (mS/m) siemens per meter (S/m) 10,000 microsiemens per centimeter
(µS/cm)
Electrical resistivity ohm-meters (ohm-m) 0.001 kiloohm-meters (kohm-m)
Electrical conductivity in siemens per meter [S/m] can be converted to electrical resistivity in ohm-meters [ohm m] as follows: = 1/.
Electrical conductivity in millisiemens per meter [mS/m] can be converted to electrical resistivity in ohm-meters [ohm m] as follows: = 1,000/.
Electrical conductivity in microsiemens per centimeter [µS/cm] can be converted to electrical resistivity in ohm-meters [ohm m] as follows: = 10,000/.
Electrical resistivity in ohm-meters [ohm m] can be converted to electrical conductivity in siemens per meter [S/m] as follows: = 1/.
Electrical resistivity in ohm-meters [ohm m] can be converted to electrical conductivity in millisiemens per meter [mS/m] as follows: = 1,000/.
Electrical resistivity in ohm-meters [ohm m] can be converted to electrical conductivity in microsiemens per centimeter [µS/cm] as follows: = 10,000/.
Specific conductance (SC) refers to fluid electrical conductivity corrected to a temperature of 25 °C. The units of specific conductance are usually in microsiemens per centimeter [µS/cm].
The above conversions apply.
Temperature in degrees Celsius (°C) may be converted to degrees Fahrenheit (°F) as follows:
°F= (1.8x°C)+32 Temperature in degrees Fahrenheit (°F) may be converted to degrees Celsius (°C) as follows:
°C= (°F-32)/1.8 Vertical coordinate information is referenced to the National Geodetic Vertical Datum of 1929 (NGVD 29).
Horizontal coordinate information is referenced to the North American Datum of 1983 (NAD 83).
Altitude, as used in this report, refers to distance above the vertical datum.
- Transmissivity: The standard unit for transmissivity is cubic foot per day per square foot times foot of aquifer thickness [(ft3/d)/ft2]ft. In this report, the mathematically reduced form, foot squared per day (ft2/d) or meters squared per day (m2/d), is used for convenience.
Specific conductance is given in microsiemens per centimeter at 25 degrees Celsius
(µS/cm at 25 °C).
Concentrations of chemical constituents in water are given either in milligrams per liter (mg/L) or micrograms per liter (µg/L).
xi Abbreviations Ar Argon ABI Acoustic borehole image CCS Cooling canal system cc STP/g Cubic centimeters at standard temperature and pressure per gram cps Counts per second CU-LDEO Columbia University, Lamont-Doherty Earth Observatory Noble Gas laboratory EMI Electromagnetic induction ENSO El Nino-Southern Oscillation FEC Florida East Coast FEM Frequency-domain electromagnetic FGDC Federal Geographic Data Committee FKAA Florida Keys Aqueduct Authority FPL Florida Power and Light GIS Geographic information system GMWL Global meteoric water line GWSI USGS Ground Water Site Inventory system HEM Helicopter electromagnetic 3
H Tritium 2
H/1H Isotopic ratio of deuterium to hydrogen Hz Hertz kHz Kilohertz LEL Local evaporation line LSWML Local saltwater mixing line Ma Million years M-D DERM Miami-Dade County Department of Environmental Resource Management M-D PERA Miami-Dade County Permitting, Environmental, and Regulatory Affairs N2 Nitrogen N2/Ar Nitrogen/argon NOAA National Oceanic and Atmospheric Administration OBI Optical borehole image ORP Oxygen Reduction Potential 18 O/16O Isotopic ratio of oxygen-18 to oxygen-16 PDF Portable Document Format ppm parts per million ppt parts per thousand pptv parts per thousand total volume PSU Practical salinity units PVC Polyvinyl chloride Q Quaternary SF6 Sulfur hexafluoride SP Spontaneous potential SPR Single-point resistance SST Sea surface temperature TDS Total dissolved solids TEM Time-domain electromagnetic TSEMIL Time-series electromagnetic induction log USEPA U.S. Environmental Protection Agency USGS U.S. Geological Survey USGS-SI&T USGS Stable Isotope and Tritium USGS-RCL USGS Reston Chlorofluorocarbon Laboratory VSMOW Vienna Standard Mean Ocean Water WCA Water Conservation Area
Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater in Miami-Dade County, Florida By Scott T. Prinos, Michael A. Wacker, Kevin J. Cunningham, and David V. Fitterman Abstract supported by the similarity in the oxygen and hydrogen stable isotope composition in samples from the Snapper Creek Canal, Intrusion of saltwater into parts of the shallow karst 1.6 kilometers (km) inland of a salinity control structure, and Biscayne aquifer is a major concern for the 2.5 million residents in samples from well G-3608, which is adjacent to the canal, of Miami-Dade County that rely on this aquifer as their primary as well as by the relative ages of the water sampled from well drinking water supply. Saltwater intrusion of this aquifer began G-3608 and other wells open to the aquifer below the saltwater when the Everglades were drained to provide dry land for urban interface. Historical and recent salinity information from the development and agriculture. The reduction in water levels Card Sound Road Canal, monitoring well FKS8 located adjacent caused by this drainage, combined with periodic droughts, to the canal, and the 2001 helicopter electromagnetic survey allowed saltwater to flow inland along the base of the aquifer indicated that saltwater may occasionally leak from this canal as and to seep directly into the aquifer from the canals. The far inland as 15 km. This leakage may be prevented or reduced approximate inland extent of saltwater was last mapped in 1995. by a salinity control structure that was installed in May 2010.
An examination of the inland extent of saltwater and Saltwater also may have leaked from the Princeton Canal.
the sources of saltwater in the aquifer was completed during Results of geochemical sampling and analysis indicate 2008-2011 by using (1) all available salinity information, a close correspondence between droughts and saltwater (2) time-series electromagnetic induction log datasets from intrusion. Tritium/helium-3 apparent (piston-flow) ages deter-35 wells, (3) time-domain electromagnetic soundings collected mined from samples of saltwater with chloride concentrations at 79 locations, (4) a helicopter electromagnetic survey done of about 1,000 milligrams per liter (mg/L) or greater generally during 2001 that was processed, calibrated, and published corresponded to a period during which droughts were frequent.
during the study, (5) cores and geophysical logs collected Comparison of average daily air temperatures in Miami, from 8 sites for stratigraphic analysis, (6) 8 new water-quality Florida, with estimates of recharge temperatures determined monitoring wells, and (7) analyses of 69 geochemical samples. from the dissolved gas composition in water samples indicated The results of the study indicate that as of 2011 that saltwater likely entered the aquifer in April or early May approximately 1,200 square kilometers (km2) of the mainland when water levels are typically at their lowest during the year.
part of the Biscayne aquifer were intruded by saltwater. The Conversely, most of the samples of freshwater with chloride saltwater front was mapped farther inland than it was in concentrations less than about 1,000 mg/L indicate recharge 1995 in eight areas totaling about 24.1 km2. In many of these temperatures corresponding to air temperatures in mid to late areas, analyses indicated that saltwater had encroached along May when rainfall and water levels in the aquifer increase, and the base of the aquifer. The saltwater front was mapped closer the piston-flow ages of these samples correspond to wet years.
to the coast than it was in 1995 in four areas totaling approxi- The piston-flow ages of freshwater samples generally were mately 6.2 km2. The changes in the mapped extent of saltwater younger than ages of samples of saltwater.
resulted from improved spatial information, actual movement Saltwater samples that were depleted in boron, of the saltwater front, or a combination of both. magnesium, potassium, sodium, and sulfate, and enriched in Salinity monitoring in some of the canals in Miami-Dade calcium relative to the concentrations theoretically produced County between 1988 and 2010 indicated influxes of saltwater, by freshwater/seawater mixing, generally were found to with maximum salinities ranging from 1.4 to 32 practical be associated with areas where saltwater had recently salinity units (PSU) upstream of the salinity control structures. intruded. The calcium to (bicarbonate + sulfate) molar ratios Time-series electromagnetic induction log data from monitoring (Ca/(HCO3+SO4)) of these samples generally were greater wells G-3601, G-3608, and G-3701, located adjacent to the than 1. Saltwater samples from some of the monitoring wells, Biscayne, Snapper Creek, and Black Creek Canals, respectively, however, indicated little or no enrichment or depletion of these and upstream of the salinity control structures, indicated ions relative to the theoretical freshwater/seawater mixing line, shallow influxes of conductive water in the aquifer that likely and the Ca/(HCO3+SO4) molar ratios of these samples generally resulted from leakage of brackish water or saltwater from these were less than 1. Results indicated that aquifer materials are canals. The determination that saltwater influxes were recent is approaching equilibrium with seawater at these well locations.
2 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Introduction U.S. Geological Survey, 2011g). This website allows the USGS to deliver timely hydrologic data, analyses, and The Biscayne aquifer underlying the study area (fig. 1) decision-support tools concerning saltwater intrusion. The in Miami-Dade County and southern Broward County in results of this study, summarized in this report: (1) provide Florida is prone to saltwater intrusion because this area has needed information regarding the amount and quality of water low land-surface altitude and a low topographic gradient and in Miami-Dade County (2) advance the monitoring network is bordered to the east and south by sources of saltwater in the and techniques for determining water quality, and (3) advance Atlantic Ocean, Biscayne Bay, and Florida Bay. The aquifer understanding of the process of saltwater intrusion, which can is part of the surficial aquifer system, is semi-confined, and affect water availability.
consists primarily of highly permeable limestone. Prior to development, much of Miami-Dade County was covered by Definition of Terms the shallow marshes of the Everglades (fig. 2A). Beginning in the early 20th century to provide land for urban develop- The following definitions are used in this report:
ment, flood control, irrigation, and agriculture, a large part
- Brackish water - Water with chloride concentrations of the Everglades in this county was drained by a network of ranging from 251 to 1,000 milligrams per liter (mg/L).
uncontrolled or inadequately controlled canals (Leach and others, 1972, p. 23) that extended to the bays and the ocean.
- Freshwater - Water meeting the U.S. Environmen-This drainage and subsequent water-supply withdrawals tal Protection Agency (USEPA) secondary drinking reduced water levels in the aquifer. These water-level declines water standards for chloride concentrations less than were exacerbated during droughts and allowed saltwater to or equal to 250 mg/L (U.S. Environmental Protection intrude some water-supply wells and municipal well fields in Agency, 2011a).
Miami-Dade County.
In December 1939, the U.S. Geological Survey (USGS)
- Saltwater - Water having a chloride concentration began salinity and water-level monitoring in the Biscayne of greater than or equal to 1,000 mg/L. This value is aquifer. Shortly thereafter, water-resource managers began based on previous mapping efforts in southeast Florida implementing strategies to mitigate saltwater intrusion. The (Klein and Waller, 1985; Koszalka, 1995).
extent of saltwater intrusion was last mapped in 1995 (Sonen-
- Saltwater encroachment - A specific type of saltwater shein, 1997). Since 1995, salinity monitoring has indicated intrusion that is caused by the gradual lateral move-that saltwater has intruded farther inland in some locations and ment of saltwater from the sea inland along the base has receded seaward in others. At some locations, data were of the aquifer as a result of decreases of the freshwater insufficient to indicate the current extent of saltwater intrusion head in the aquifer relative to sea level.
or to determine whether changes had occurred. Furthermore, information on monitoring well construction indicated that
- Saltwater front - The farthest inland extent of saltwater some of the existing monitoring wells cannot provide the intrusion in the aquifer. In some instances there is quality of information necessary to fully evaluate movement brackish water from previous intrusion events or of the saltwater front in the Biscayne aquifer. residual connate water that occurs inland of the To address these concerns, the USGS, in cooperation saltwater front.
with Miami-Dade County, began a study in 2008 to:
delineate the current extent of saltwater intrusion in the
- Saltwater interface - A zone of transition between Biscayne aquifer; characterize how the extent has changed intruded saltwater and freshwater in the aquifer.
since the last mapping effort; improve salinity monitoring Sometimes this interface is sharp. Often this interface in the Biscayne aquifer; and identify the sources of the is diffuse and allows mixing between the two masses saltwater to better understand the actions required to prevent of water.
or mitigate saltwater intrusion. As part of this effort, eight
- Saltwater intrusion - A generic term referring to an new monitoring wells were installed in areas where there influx of saltwater through various pathways into was insufficient information to identify the location of the an aquifer.
front, and data from geophysical tools and techniques were incorporated into the analysis. To improve accessibility of
- Salinity - (1) A quantitative term describing the salinity monitoring information to the public, the USGS measured concentration of dissolved solids in water cooperative water conditions website was enhanced to allow expressed as practical salinity units (PSU) or in parts panning, zooming, and layer selections. The improved per thousand (ppt). (2) A generic term referring to vari-website, Saline Intrusion Monitoring, Miami-Dade County, ous types of information describing the concentration Florida, serves data collected during this study, as well as of dissolved solids in water. Information may include data from the active salinity monitoring network, and provides measurements of the electrical conductivity of water, the interpreted maps of the inland extent of saltwater intrusion airborne, borehole, or surface geophysical measure-(http://www.envirobase.usgs.gov/FLIMS/SaltFront/viewer.htm, ments, or sample results.
Introduction3 80°30' 80°20' 80°10' 820 "
L-33 HOLLYWOOD 26°00' A 7
L-67 C
67 95 75 L-BROWARD Snake Creek Ca COUNTY na l FLORIDA MIAMI-DADE 997 -9 )
W. E. Oeffler (C COUNTY 821 826 Biscayne Canal (C
-8)
Westside L-30 Northwest S-28 M 9 iam Hialeah Lake Okeechobee i
Preston MIAMI 25°50' Miami Springs Ft. Myers Upper " CaSPRINGS "
na Miami l Naples
- (C
-6 River Spring 195 "
Miami Springs S-26 ) Rapids Gardens Lower Florida Bay 836 Vaca Key
" Study MIAMI Key West Tamiami Canal (C-4) area Silver Bluff Coconut OCEAN Grove Alexander Orr COCONUT Snapper GROVE ATLANTIC Creek West Snapper Canal Southwest Creek (C-2) 25°40'
- Bay S-22 1 ne cay Florida Turnpike L-31N Bis Pri Naranja nce S-21 #
ton Park Canal (C-102)
Leisure Homestead M
owCity Airforce S-21A 25°30' Redavo ry Base Wittkop Park Cana l (C-103)
- S-20F HOMESTEAD " S-179 #
Florida City Newton Florida Keys Florida City Canal Aqueduct FLORIDA CITY Authority Everglades 1
Labor Camp MODEL LAND Ae FPL Cooling ro Modal Land Canal je Ca EXPLANATION Canal System t S (C-107) rd ou # Study area nd Canal (C-111)
R dR S-20 un Well fields So 25°20' rd al
- Ca d Can Water Conservation Area 3A S-18C oa u nd So Water Conservation Area 3B oa rd d
- S-197 Ca Biscayne National Park Everglades National Park 2001 Helicopter electromagnetic Bar Sou nes survey area nd S-20# Structure location and number Base from Miami-Dade County, South Florida Water Management 0 5 10 KILOMETERS and U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 0 5 10 MILES Figure 1. Location of the study area, well fields, the National Parks, water conservation areas, and the helicopter electromagnetic survey of 2001, Miami-Dade and Broward Counties, Florida.
4 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
µ 81°20' 81°00' 80°40' 80°20' 80°00' 27°00' 26°40' 26°20' B
26°00' 25°40' 25°20' 0 5 10 KILOMETERS 0 5 10 MILES Figure 2. (A) Map created for the Annual Report of the Surveyor General for 1859, New York, NY, General Land Office, 1859, courtesy of the Geography and Map Division of the Library of Congress.
Latitude and longitude grid georeferenced to the coordinate system of original map to the extent possible, given inaccuracies in original map. (B) Digital elevation map showing the topography of the study area in Miami-Dade County and southern Broward County. Altitudes are referenced to the National Geodetic Vertical Datum of 1929 (NGVD 29). Prior to conversion to meters, altitudes were initially referenced to the North American Vertical Datum of 1988 by the Florida Division of Emergency Management by using the results of a light detection and ranging (LIDAR) study (2009), and NGVD 29 altitudes were estimated with a +0.46-meter adjustment factor.
Introduction5 B
80°30' 80°20' 80°10' 26°00' BROWARD COUNTY MIAMI-DADE COUNTY 25°50' AN IC OCE ATLAN T
25°40' Bay EXPLANATION ayne Altitude Bisc High: 6.4 Meters Shelf edge 4.0 Meters 3.0 Meters 1.3 Meters 25°30' Low: Sea Level 0 2.5 5 KILOMETERS 0 2.5 5 MILES Base from U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 Figure 2. (A) Map created for the Annual Report of the Surveyor General for 1859, New York, NY, General Land Office, 1859, courtesy of the Geography and Map Division of the Library of Congress.
Latitude and longitude grid georeferenced to the coordinate system of original map to the extent possible, given inaccuracies in original map. (B) Digital elevation map showing the topography of the study area in Miami-Dade County and southern Broward County. Altitudes are referenced to the National Geodetic Vertical Datum of 1929 (NGVD 29). Prior to conversion to meters, altitudes were initially referenced to the North American Vertical Datum of 1988 by the Florida Division of Emergency Management by using the results of a light detection and ranging (LIDAR) study (2009), and NGVD 29 altitudes were estimated with a +0.46-meter adjustment factorContinued.
6 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Purpose and Scope monitoring wells installed as part of this study, as well as from several new wells that had been installed by other organiza-The purpose of this report is to document the methods tions. A preliminary map of the saltwater front was completed used to (1) delineate the current inland extent of saltwater in October 2008 using data available at that time. A final map intrusion, (2) examine the origins of saltwater intrusion, was completed in 2011 using the additional data collected and (3) describe the spatial and temporal changes in the during the study and made available from other organizations.
distribution of saltwater in the Biscayne aquifer in eastern Time-series water-quality and time-series electromagnetic Miami-Dade County. The analyses presented herein describe induction log (TSEMIL) datasets were used to evaluate the how saltwater from Biscayne Bay, Barnes Sound, Card changes that occurred in the location of the saltwater front Sound, Florida Bay, or the Atlantic Ocean (fig. 1) has been between 1995 and 2011 and to distinguish between changes in transported, and may continue to be transported within the the mapped location of the saltwater front resulting from front Biscayne aquifer. The study area extends westward from the movement and changes that likely resulted from improved coast as far as is required to describe saltwater in the Biscayne spatial monitoring network coverage.
aquifer from these sources. To identify the sources of salinity, water-quality samples This report includes discussions of the (1) extent of were collected for evaluation of the analytes alkalinity, saltwater intrusion, (2) environmental and anthropogenic barium, boron, bromide, calcium, chloride, fluoride, iron, causes of saltwater intrusion, (3) temporal and spatial changes magnesium, potassium, silica, sodium, strontium, sulfate, in the distribution of saltwater, (4) effects of urban and sulfur hexafluoride (SF6), uranium, tritium (3H); field proper-hydrologic development on saltwater intrusion, (5) types of ties including dissolved oxygen, pH, specific conductance, data collected, collection methods, and analytical methods, and and temperature; and the isotopic ratios of tritium and helium (6) limitations of this analysis. Geophysical data include time- (3H/3He ), oxygen (18O/16O), hydrogen and deuterium (2H/1H),
domain electromagnetic (TEM) soundings, a helicopter electro- and strontium (87Sr/86Sr). Selected sites were sampled to magnetic (HEM) survey, and electromagnetic induction (EMI) evaluate the apparent age of the water using 3H/3He and logs. A procedure developed during the study for interpretation SF6 age-dating methods. Selected samples were analyzed to of EMI log data is presented. TEM soundings also were used evaluate dissolved gas composition and terrigenic helium to evaluate the depth of the base of the Biscayne aquifer. This concentration. The analytes evaluated for each sample varied effort provided an evaluation of the quality of models devel- and were selected based on well construction, well installation oped from geophysical data and of the use of these models to date, sampling methods used, and study needs. The informa-augment existing stratigraphic information. Understanding the tion was interpreted to evaluate whether the saltwater sampled depth of the base of the Biscayne aquifer is important to this was relict or recent.
study because the toe of the wedged-shaped saltwater front typically extends farthest inland at the base of a given aquifer.
Description of Study Area Water chemistry analyses included determinations of dissolved gas concentrations, major and trace ion concentrations, stable The study area (fig. 1) is primarily the eastern part of isotope ratios, and tritium/helium-3 (3H/3He) age dating. These Miami-Dade County, Florida. The northern boundary is analyses were combined with time-series salinity data and in Hallandale Beach in southern Broward County, Florida geophysical information to evaluate the sources of saltwater (fig. 1). The southern boundary is the Florida Bay. Generally in the aquifer. Information on the construction of the eight the study area extends about 8 to 11 km (6 to 7 miles) inland new monitoring wells is included in the appendixes, including from the coast or Biscayne Bay. In the southern part of the borehole geophysical log data. Borehole geophysical data were county, however, the study area extends westward to the used to enhance the interpretation of the hydrogeology of the Aerojet (C-111) Canal.
Biscayne aquifer in Miami-Dade County. The procedures used to collect, model, and evaluate the TEM soundings collected for this study have been published separately (Fitterman Hydrologic Controls and Prinos, 2011). The calibration and interpretation of the 2001 HEM survey undertaken as part of this study are Saltwater intrusion is controlled by factors including presented in Fitterman and others (2012). (1) climatic conditions that result in wet and dry seasons, droughts, and floods; (2) the distribution of porosity within the sand and karst limestone layers of the Biscayne aquifer, (3) a Approach general eastward and southeastward groundwater-flow direc-tion, (4) freshwater levels in the aquifer relative to sea level, Water-quality data, including ongoing salinity and specific (5) generally low land-surface altitude (fig. 2B), (6) a low conductance monitoring data provided by various organiza- regional flow gradient, and (7) a water management system tions, and information from TEM soundings, EMI logs, and including drainage canals, water control structures, pumps, a HEM survey, were entered into a geographic information levees, water-supply well fields, and water conservation areas system (GIS). This information was used to construct a map of (fig. 1). High permeability surface materials or karst features the current saltwater front. Additional specific conductance and allow rapid recharge of the aquifer or surface sheet flow when chloride concentration samples were collected from the eight groundwater levels rise above the land surface.
Introduction7 Topography and Physiography Waller, 1985; Bridges and others, 1991, p. 231-238); 1980-82 (Waller, 1985; Bridges and others, 1991, p. 231-238); 1985 Miami-Dade County is generally flat and poorly drained. (South Florida Water Management District, 1985), 1989-90 The land-surface altitude for approximately 70 percent of the (Trimble and others, 1990), and 1998-2002 (Verdi and county is below 1.8 m. Figure 2A is a historical map showing others, 2006). Drought periods are shown on a graph of the predevelopment extent of the everglades. Areas shown average annual total rainfall during 1931 to 2011 (fig. 4). To as everglades in figure 2A correspond to areas that currently construct this graph, average monthly total rainfall at eight have land-surface altitudes of about 0 to 3.0 m (fig. 2B). East long-term monitoring stations was computed and totaled of the Everglades is the Atlantic Coastal Ridge physiographic annually. Selected stations had data that were 69 to 97 percent province (figs. 2B and 3), which ranges in altitude from 2.4 to complete for the evaluated period. The following National 7.3 m (Hoffmeister and others, 1967, p. 176; Lietz, 1999). East Oceanic and Atmospheric Administration, National Climatic and south of the Atlantic Coastal Ridge is the low lying (fig. 2B) Data Center stations were used: Everglades (1931-2011),
Coastal Marsh and Mangrove physiographic province (fig. 3). Fort Lauderdale (1931-2011), Hialeah (1941-2011),
Homestead Experimental Station (1931-1988), Miami Beach (1941-2011), Miami International Airport (1948-2011), Royal Climate Palm Ranger Station (1949-2011), and Tamiami Trail 40 Mile The wet and dry tropical climate (Hagemeyer, 2012) of Bend (1941-2006) (fig. 3). The 1998 to 2002 drought (fig. 4) south Florida is created by a combination of its latitude and was not as severe in Miami-Dade County as it was in other proximity to the ocean and the Gulf of Mexico. Although areas. During this period, the rainfall in Miami-Dade County Miami-Dade County is farther south than most of the United was lower than normal only in 2000, and the drought period States, buffering from the Atlantic Ocean ensures that summer was shorter (fig. 4) than in other parts of the State. Based on temperatures rarely exceed 38 °C, and winter temperatures the rainfall data, it appears that the 1985 and 1989-90 drought rarely fall below freezing. The highest and lowest tempera- periods were of longer duration in Miami-Dade County than tures typically occur during August and January, respectively. in other parts of the State and combined to form one extended Daily mean temperature averages about 28 °C in August drought period from 1984 to 1990 (fig. 4).
and 20 °C in January (National Climatic Data Center, 2012).
A wet season occurring from mid-May through September Water Use in Miami-Dade County of each year is typified by afternoon thunderstorms with relatively heavy rainfall that is augmented by rainfall from Miami-Dade Countys population of 2,496,000 (U.S. Census tropical storms and hurricanes. During the wet season, solar Bureau, 2010) makes Miami-Dade County one of the most radiation induces the movement of moist air inland from the populous counties in the United States. As of 2010, the ocean (Hagemeyer, 2012), where it combines with evaporating vast majority of the countys residents lived in an area of water from the swamps and wet prairies to produce frequent approximately 1,550 square kilometers (km2) that is within and generally localized thunderstorms. The low humidity and about 24 kilometers (km) of the ocean or Biscayne Bay. As solar radiation occurring during the dry season that extends the population of Miami-Dade County has increased, demand from October to early May greatly reduce the occurrence of for freshwater also has increased. The Biscayne aquifer is afternoon thunderstorms. Relatively low sea-surface tempera- the principal aquifer for the residents of Miami-Dade County tures during December to May also reduce the likelihood of (Miller, 1990). Ninety-nine percent of all groundwater tropical storms; consequently, rainfall during the dry season withdrawn in Miami-Dade County in 2005 emanated from is caused primarily by the interaction of cold fronts from the the Biscayne aquifer (Marella, 2009). Public groundwater north with moist tropical air in the south. withdrawals generally have increased as population increased The occurrence of hurricanes, tropical storms, and during 1965 to 1987 (fig. 5) (Marella, 1999, 2009; R.L.
droughts in south Florida is related to a large extent to the Marella, U.S. Geological Survey, written commun., 1998, El Nino-Southern Oscillation (ENSO). El Nino periods are 2011; U.S. Census Bureau, 2013). Although population characterized by unusually warm sea surface temperatures continued to increase at a relatively steady rate during 1993 to (SSTs) south of the equatorial eastern Pacific Ocean, whereas 2006, there was only a marginal increase in public ground-La Nina periods are characterized by unusually cool SSTs water withdrawals during this same period (fig. 5). Since 2006, in this region. El Nino periods tend to draw the jet stream public groundwater withdrawals have decreased as population southward, which produces wind shear that hampers the has continued to increase. This decrease may be, at least in formation of tropical storms and hurricanes but also increases part, the result of stricter water use restrictions that began in the likelihood of precipitation in south Florida. La Nina May 2007 when water levels in Lake Okeechobee declined to periods result in less precipitation and more persistent high record minimums. These water use restrictions were still in pressure systems in south Florida, which increases the poten- effect at the time of this report. The Biscayne aquifer is also tial for droughts (Hagemeyer, 2012). Prolonged droughts in the primary source of potable water for all residents living in Florida occurred in 1938-39 and 1943-46 (Parker and others, the Florida Keys, Monroe County (Marella, 2009). Water from 1955); 1949-57 (Waller, 1985; Bridges and others, 1991, the Biscayne aquifer is delivered by an aqueduct that extends
- p. 231-238); 1960-63 (Waller, 1985; Bridges and others, from the Florida Keys Aqueduct Authority (FKAA) well field 1991, p. 231-238); 1970-77 (Benson and Gardner, 1974; west of Florida City south to Key West (fig. 1). Although the
8 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 80°50' 80°40' 80°30' 80°20' 80°10' BROWARD COUNTY COLLIER COUNTY MIAMI-DADE COUNTY 75 27 1
826 95 821 25°50' " Hialeah Miami International " "
Tamiami Trail Airport 836 Miami 40 Mile Bend Beach
" 41 A' A
MONROE COUNTY AN IC OCE 25°40' Bay ATLAN MIAMI-DADE COUNTY T
ayne Bisc 1
Homestead Experimental Station 25°30' "
821 Royal Palm 9336 Ranger Station "
d un So rd 25°20' Ca 1
FLORIDA B
So arne un s d
Ft. Lauderdale Bay 25°10' Florida Everglades Base from U.S. Geological Survey digital data, 0 5 10 KILOMETERS EXPLANATION Universal Transverse Mercator projection, zone 17 PHYSIOGRAPHIC PROVINCES 0 5 10 MILES Atlantic Coastal Ridge Everglades Big Cypress Swamp Gulf or Bay Coastal Marsh and Sandy Flatwoods Mangrove A A' Cross section Hialeah Rainfall monitoring (see figure 7) station and site name Figure 3. Physiographic provinces, location of the cross section shown in figure 7, and locations of rainfall monitoring stations within the study area. Modified from Lietz (1999).
Introduction9 90 1938 1943 1949 1960 1970 1980 1984 2000 to to to to to to to 80 1939 1946 1957 1963 1977 1982 1990 Estimated total annual precipitation, in inches 70 60 50 40 30 20 10 0 1931 1933 1935 1937 1939 1941 1943 1945 1947 1949 1951 1953 1955 1957 1959 1961 1963 1965 1967 1969 1971 1973 1975 1977 1979 1981 1983 1985 1987 1989 1991 1993 1995 1997 1999 2001 2003 2005 2007 2009 2011 Year EXPLANATION 1985 Documented drought period and year(s)
Estimated average total annual precipitation for 1931-2011 Estimated total annual precipitation 3-year moving average (estimated total annual precipitation)
Figure 4. Estimated total annual precipitation from selected stations in or near Miami-Dade County and documented droughts during 1931 to 2011.
2,600,000 2,000 1,900 Public groundwater withdrawals, in million liters per day 2,400,000 1,800 1,700 2,200,000 1,600 1,500 Estimated population 2,000,000 1,400 1,300 1,800,000 1,200 1,100 1,600,000 1,000 1,400,000 900 800 EXPLANATION 700 1,200,000 Estimated population Water withdrawals 600 1,000,000 500 1960 1965 1970 1975 1980 1985 1990 1995 2000 2005 2010 Year Figure 5. Estimated population (from U.S. Census Bureau, 2013) and public groundwater withdrawals in Miami-Dade County, Florida.
10 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater spatial extent of the Biscayne aquifer is limited primarily to aquifer is wedge-shaped and becomes thinner toward the Broward, Miami-Dade, and Palm Beach Counties, it provided western part of Miami-Dade County (fig. 7). The deepest 33 percent of all public-supply groundwater used in Florida as part of the Biscayne aquifer is approximately 55 m deep in of 2005 (Marella, 2009). the northeastern part of the county (Fish and Stewart, 1991).
The depth of the base of the Biscayne aquifer in the area of the HEM survey in southern Miami-Dade County varies Hydrogeology/Hydrostratigraphic Framework from about 17 to 30 m (Fish and Stewart, 1991). Fish and The study area is underlain by the surficial aquifer Stewart (1991) show that the two aquifers merge with one system, the intermediate confining unit, and the Floridan another in central and northern coastal Miami-Dade County aquifer system (fig. 6). In the study area, the surficial (fig. 7). Both aquifers are composed mostly of highly porous, aquifer system corresponds with the Tamiami Formation karstic limestone, and the Biscayne aquifer is by far the more of Pliocene age; the Fort Thompson Formation, Key Largo productive of the two. Where the two aquifers are distinct, Limestone, Miami Limestone, and Pamlico Sand (Schroeder the top of the gray limestone aquifer is separated from the and Klein, 1954) of Pleistocene age, and the Lake Flirt Marl base of the Biscayne aquifer by an upper semiconfining unit of Holocene age (Parker and Cooke, 1944; Causaras, 1987; generally composed of quartz sands (figs. 6 and 7). The base Fish and Stewart, 1991; Cunningham and others, 1998; of the gray limestone aquifer is separated from the top of the Cunningham and others, 2001; Cunningham and others, 2004; underlying intermediate confining unit by a semiconfining unit Cunningham and others, 2006a, b). (figs. 6 and 7). In the study area (fig. 1), the surficial aquifer The surficial aquifer system includes two aquifers: the system generally has transmissivity values that are greater Biscayne aquifer and the deeper, informally named gray than 93,000 meters squared per day (m2/d) (1,000,000 feet limestone aquifer (Fish and Stewart, 1991). The Biscayne squared per day [ft2/d]) (Fish and Stewart, 1991). One aquifer Hydrogeologic Geologic Age 87Sr/86Sr Series unit unit (Ma) Ratio Lake Flirt Marl, Undifferentiated Holocene soil and sand 0.01 0.7091748 Pamlico Sand Biscayne Miami aquifer Surficial aquifer system Limestone Key Largo Pleistocene Fort Thompson Formation Formation 2.6 0.709068 Pinecrest Semiconfining Sand Tamiami Formation unit Member Gray Ochopee Limestone Pliocene limestone SI aquifer Member Fm Semiconfining unit 5.3 0.709027 Peace Intermediate River Hawthorn Group Confining unit Formation Miocene confining unit and Late Oligocene Arcadia Formation 28.1 0.708036 Floridan aquifer Suwannee Early Upper Limestone Oligocene Floridan 33.9 0.707827 system aquifer Ocala Late Limestone Eocene 37.8 0.707743 Avon Park Formation Middle Figure 6. Generalized relation of hydrogeologic, lithostratigraphic, and time-stratigraphic units in Miami-Dade County (based on Causaras, 1987; Fish and Stewart, 1991; Cunningham and others, 2001, 2006a; Reese and Richardson, 2008; Gradstein and others, 2012; and this report). [SI Fm, Stock Island Formation]
Introduction11 A A' MONROE COUNTY ATLANTIC MIAMI-DADE OCEAN COUNTY SEA LEVEL SEA LEVEL Biscayne aquifer Surficial Semiconfining unit aquifer system Gray limestone aquifer Semiconfining unit Intermediate confining unit Hawthorn Formation system Floridan aquifer VERTICAL SCALE GREATLY EXAGGERATED 0 5 10 KILOMETERS EXPLANATION Hydrostratigraphic boundary 0 5 10 MILES Lithostratigraphic boundary Figure 7. Hydrogeologic section A-A showing hydrostratigraphy of the surficial aquifer system and uppermost part of the intermediate confining unit from west to east across central Miami-Dade County (modified from Fish and Stewart, 1991). Location of cross section shown in figure 3.
test in central Miami-Dade County indicated a transmissivity Previous Studies of 270,000 m2/d (Fish and Stewart, 1991).
The intermediate confining unit underlies the surficial The mechanisms of saltwater intrusion and the changes aquifer system (figs. 6 and 7). The intermediate confining unit in the hydrology of south Florida that allowed saltwater to is approximately 170 to 240 m thick and is composed of a intrude large parts of the Biscayne aquifer in Miami-Dade succession of quartz sand and sandstone, limestone, dolomite, County have been described by Cross and Love (1942),
and minor terrigenous mudstone, diatomaceous mudstone, Parker (1945), Parker and others (1955), Kohout and Leach and dolosilt that compose the Late Oligocene-Early Pliocene (1964), and Renken and others (2005a). Brown and Parker Hawthorn Group (Fish and Stewart, 1991; Cunningham and (1945) provided detailed examinations and a cross section others, 2001). In the study area, the intermediate confining showing saltwater encroached at Silver Bluff in Coconut unit overlies the Upper Floridan aquifer of the Floridan aquifer Grove (fig. 1). Hoy and others (1951) published six cross system (fig. 6), which is composed primarily of limestone sections showing changes in the position of the saltwater and relatively minor dolomitic limestone and dolomite front in the Miami area between 1946 and 1950. Klein (Reese, 1994). The intermediate confining unit also can (1957) provided a contour map of the saltwater front near include the lowermost part of the Tamiami Formation (Fish Silver Bluff in Coconut Grove (fig. 1). Schroeder and others and Stewart, 1991) and the Stock Island Formation. (1958) described the Biscayne aquifer in Dade (currently
12 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater named Miami-Dade) and Broward Counties and reported Prinos and others (2002) examined the chloride that, at that time in southern Broward County near the city concentrations in USGS monitoring wells during of Hollywood, saltwater had not yet encroached as far inland 1974-1999 in the Biscayne aquifer and identified statistically as U.S. Highway 1, which is about 2.4 km from the ocean. significant increasing trends in chloride concentrations in the Sherwood and Leach (1962) found that the Biscayne aquifer data from 40 percent of the wells in this aquifer. Decreasing in the vicinity of salinity control structure S-22 on the trends in chloride concentrations were identified in the data Snapper Creek Canal (fig. 1) is so permeable that if water from 28 percent of these wells. Data from 32 percent of levels upstream of the structure are higher than water levels the monitoring wells showed no quantifiable trend for the downstream of the structure, then when the structure is closed, period evaluated.
water will flow through the aquifer under the structure toward Biscayne Bay.
Sherwood and Klein (1963) evaluated the relation between surface water and groundwater in southeastern Origin of Saltwater Intrusion in Florida and provided a comparison of the water levels in Southeastern Florida Miami-Dade County near Miami with the inland extent of saltwater in the Biscayne aquifer. The relation of saltwater An understanding of the mechanisms of saltwater intrusion to discharge in the Miami River and its tributaries intrusion and the effects of urban development in southeast was evaluated by Leach and Grantham (1966). This analysis Florida is necessary for water management and development indicated that water with a chloride concentration of of remediation strategies. The management and remediation 1,000 parts per million (ppm) occurred in the Miami Canal as strategies necessary to prevent saltwater from encroaching far inland as control structure S-26 (fig. 1) about 23 percent of inland along the base of the aquifer are different from those the time and that about 60 percent of the Biscayne aquifer in needed to prevent saltwater from leaking upward from the vicinity of the Miami Canal and its tributaries could gradu- deeper aquifers. Mitigation of saltwater intrusion, while also ally be restored to freshwater conditions if the structure were addressing the frequently competing needs of flood preven-moved downstream of the confluence of the Tamiami Canal. tion, agriculture, urban development, public water supply, Kohout and Leach (1964) examined the relation between and ecosystem preservation, has resulted in a complex water water control dam operation in the Snake Creek Canal and management system of canals and water control structures salinity in the aquifer. Bearden (1974, p. 25) mapped the (fig. 8) as well as an extensive saltwater monitoring network.
potentiometric surface in southern Broward County near the city of Hollywood and provided maps showing the extent of saltwater intrusion occurring near unregulated canals. Mechanisms of Saltwater Intrusion The USGS mapped the approximate inland extent of A number of mechanisms have led to the occurrence of saltwater in the Biscayne aquifer in Miami-Dade County in saltwater in the Biscayne aquifer (fig. 9). These mechanisms 1951 (Hoy, 1952), 1978 (Swayze, 1980), 1984 (Klein and include (1) upconing of relict or residual saltwater that had Waller, 1985), and 1995 (Sonenshein, 1997) and in Broward been incorporated in relatively impermeable sediments during County in 1990 (Koszalka, 1995). Parker and others (1955) previous sea-level high stands occurring during interglacial also published a map showing the inland extent of saltwater in periods (Parker, 1945, p. 533; Bearden, 1974, p. 25), (2) the the Biscayne aquifer in Miami-Dade County that differs from gradual encroachment of saltwater from the ocean along the the map created in 1951 (Hoy, 1952), but the date that this base of the aquifer resulting from reductions in freshwater map was created is not provided.
head relative to sea level (Cross and Love, 1942, p. 501),
Klein and Ratzlaff (1989) and Sonenshein and Koszalka (3) infiltration of saltwater from coastal saltwater mangrove (1996) evaluated changes in the extent of saltwater intrusion marshes (Matson and Sanford, 1913, p. 59), and (4) the flow in the Biscayne aquifer in Miami-Dade County. Prior to the of saltwater inland through canals where it leaks into the current study, little groundwater salinity information was aquifer (Cross and Love, 1942, p. 501).
available for the area south of Florida City in southeastern Miami-Dade County; therefore, the line in the map showing the inland extent of saltwater in the Biscayne aquifer plotted Upconing of Relict Saltwater from Previous by Sonenshein (1997) was dashed in this area to indicate Sea-Level High Stands that data were insufficient. Sonenshein (1997) used the interpretations of 15 TEM soundings to augment the informa- During the Pleistocene, sea levels varied as water tion provided by monitoring wells; the majority of these was periodically stored or released by growing or melting soundings were collected near the Miami Canal. Fitterman continental ice sheets. The sand and limestone formations and Deszcz-Pan (1998, 2002) and Fitterman and others (1999) of the Biscayne aquifer consist largely of materials that interpreted TEM soundings and HEM surveys to evaluate were deposited while shallow seas covered south Florida.
saltwater intrusion in southwestern Miami-Dade County in the These materials, when first deposited, would have included Everglades National Park. connate saltwater in the pore fluids. As sea level declined,
Origin of Saltwater Intrusion in Southeastern Florida 13 saline pore fluids generally were replaced by freshwater Infiltration of Saltwater from Saltwater Marshes that flowed through the aquifer. Some of the less permeable materials, however, may have retained some of the relict Infiltration of saltwater from saltwater marshes occurs saltwater. This source of saltwater was discussed by Parker along the southern, southwestern, and southeastern coastlines and others (1955). It is also possible that some strata were of Florida, where the land surface is so low that saltwater intruded again by seawater as sea level rose during later can flow over land for approximately 1 to 3 km at high tide.
interglacial periods. The water in these saltwater marshes can become hypersaline as a result of high evaporation rates, and during droughts, reductions in freshwater levels and flows may allow the Encroachment of Seawater along the Base of saltwater in these marshes to migrate inland. Tropical storm the Biscayne Aquifer or hurricane-driven storm surge or gale-driven seiches may cause the saltwater to flow farther inland than normal, where The encroachment of seawater along the base of the it could infiltrate the aquifer. Reductions in freshwater levels Biscayne aquifer can be described by the Ghyben-Herzberg in the Everglades likely increased the potential for overland relation (Ghyben, 1889; Herzberg, 1901), applied by Brown flow of this saltwater. Installation of canals also provided a (1925, p. 17) to coastal aquifers:
pathway for inland flow of this saltwater. Meyer (1974, p. 28) reported that on the upstream side of water control structure t S-18C (fig. 8) in September 1965 the chloride peaked at h= , (1) g 1 13,370 mg/L as a result of tidal inundation during Hurricane Betsy. S-18C is 9.8 km inland from Florida Bay. Meyer (1974) also reported that the chloride concentration of the where h is the depth of saltwater below sea level, g is the water was 10,000 mg/L at least 3.2 km farther upstream specific gravity of seawater, t is the height of freshwater above from S-18C.
sea level, and the specific gravity of the freshwater is assumed to be 1. This relation describes saltwater encroachment in a homogeneous, unconfined aquifer under hydrostatic condi- Seepage from Streams or Canals in which tions. Although the Biscayne aquifer is not homogeneous Saltwater has Migrated Inland and flow conditions are not hydrostatic, this relation can be used to derive a coarse approximation of the freshwater Parker and others (1955, p. 621) described the potential head necessary to prevent saltwater intrusion in the Biscayne migration of saltwater up canals in terms of a balance of aquifer. Given a specific gravity of 1.0268 for seawater in the seawater and freshwater heads. Well-designed salinity Miami area (Parker and others, 1955, p. 573), the interface control structures can potentially reduce or prevent saltwater between fresh and saltwater in the aquifer will be depressed encroachment along the base of the aquifer and the seepage by approximately 37.3 m for each meter of freshwater head of saltwater from canals by retaining sufficient freshwater above sea level. The Ghyben-Herzberg relation indicates that in the canal to increase the hydraulic head in the canals and the altitude of freshwater must be 0.6 to 1.5 m above sea level in the aquifer adjacent to canals and by directly preventing to prevent encroachment of saltwater along the base of the the flow of saltwater upstream. Salinity control structures in aquifer because the base of the Biscayne aquifer ranges from Miami-Dade County, however, have not always prevented 24 to 55 m below land surface near the east coast of Miami- saltwater intrusion. The extensive secondary porosity of layers Dade County (Fish and Stewart, 1991). Altitudes of freshwater within the Biscayne aquifer potentially can allow saltwater in some areas of coastal Miami-Dade County are well below flow around the structures through the aquifer (Leach and these altitudes (U.S. Geological Survey, 2011f); consequently, Grantham, 1966, p. 25) unless grout walls or other such some saltwater encroachment has occurred. features were installed to prevent this flow. Between 1988 and The full extent of encroachment predicted by the 2010 there have been, for example, frequent influxes of Ghyben-Herzberg relation does not occur in some parts of water, with a salinity of between 15 and 32 PSU at station the Biscayne aquifer because the relation describes a static BS04 (Maria Idia Macfarlane, Water and Sewer Department, balance of densities, rather than the dynamic forces actually written commun., March 7, 2011; Craig Grossenbacher, occurring within the aquifer (Kohout, 1964). The direction of Miami-Dade County Permitting, Environmental, and Regula-fresh groundwater flow in the Biscayne aquifer is typically tory Affairs, written commun., July 7, 2010) in the Biscayne from inland toward the coast, and the gradient increases Canal (fig. 10), which is upstream of the salinity control during periods of recharge. Kohout (1964) determined that structure S-28 (fig. 8).
saltwater (1) tends to flow inland along the base of the aquifer, In the Snake Creek Canal, when the salinity control (2) becomes less dense and flows upward as it mixes with structure was open, water from the shallow aquifer drained freshwater at the freshwater-saltwater interface, and then toward the canal, the saltwater front at the base of the (3) flows back toward the sea along with the freshwater Biscayne aquifer moved inland, and leakage of saltwater flowing seaward. from the canal into the aquifer was reduced or eliminated
80°30' 80°20' 80°10' MIA242 ! G-2956 G-2477 FLORIDA 7 MIA239 G-2478 26°00' MIA240 G-2410 MIA237 J" J"
J G-2409 MIA238 "
J!!!! G-1435 27 MIA241 G-2294 MIA115 " !
J G-2965 G-2903 MIA135 "
J 75 Snake Creek Canal G-3949 "
J MIA114 Lake Okeechobee (C
BROWARD COUNTY # -9)
S-30 C9 Canal MIAMI-DADE near NE 17 Ave G-3705 G-3600 COUNTY S-32#
- S-31 !!
S-32A 821 MIA131 ""
J MIA130 J ! # Study 997 826 MIA113 " !
Canal (C- J Key West area Biscayne 8) G-3948 J
95 MIA112 G-894 # G-58 G-3601 ! !
C8 Canal at G-3601 Arch MIA124 ! F-279 Creek MIA122 " J" BS04 MIA123 J
- G-72 #
M Little River Canal (C-7) G-3224 S-28 EXPLANATION iam iC G-3602 Approximate inland extent of saltwater an ! !
al 1955 (C 9 MIA133 LR06 # S-27
-6
) MIA134 1995 MIA132 !"J 2011 Miami Canal G-3947 25°50' ! at Water Plant "
J J
F-45 Lines are dashed where information G-3250 !
G-355 G-3603 ! was insufficient for an accurate G-548 ! G-1354 S-26 1 estimate G-571 ! ! ! 195 G-354 ! # !
J J G-3704 "
J Time-domain electromagnetic soundings G-1351 MIA121 Comfort MIA120
- S-25B ! U.S. Geological Survey groundwater-Canal (C-5) ! G-3604 S-25 395 level monitoring well 836 J# S-338 #
MIA119 Water-control or salinity-control S-335 # S-25A MIA117 " "
J J! MIA118 Miami C5 Canal MIA116 G-3605 River structure Tamiami Canal (C-4) Cor at NW 32 Ct S-336 G-119 al G-3888 !
- # S-24 # 41 Salinity monitoring sites by organization S-334 G-3229 ! ! Florida Keys Aqueduct Authority Gables 972 G-93 OCEAN Ca na 1 EAS Engineering, Inc.
l (C-3)#
G-432 Bay MIA107 " U.S. Geological Survey J ! ! yne !
G-3606 Miami-Dade County Permitting, S-24A # Bis Environmental, and Regulatory ca ATLANTIC Affairs Sn ap G-3607 G-901 per Cr !
J eek Canal J" (C-100)
MIA126 " MIA125 S-121 14 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 94 # C2 Canal 150ft G-1009B ! !!
G-896 C2 Canal upstream of S-22 G-3608 at G-3608 MIA105 MIA106 "J" J!
- G-3609 !# ! SP04 25°40' Cutler S-120 Can G-211 S-22 0C
- S-338 "
J MIA127 "
J alC-1 ! G-3887 Canal C100A Canal C-10 Dr MIA128 00A at SW 72 Ave a in S-119
- ! ! G-3313C Ca nal !
G-3313E B G-3610 el-Ai #S-118 G-3611
S-331 ! G-939 G-114 # CD02 !
- nal #S-123 S-173 Bla ire C a J MIA108 " MIA109 J MIA110 S-182A "
J S-122 MIA129 " MIA111 re !
ck C J!
S-194 ek MIA129 Princ S-149 821
- eto Ca n G-3886 !
n al G-3612 Ca (C
-1 nal )
- Florida City S-148 G-3702 Canal at G-3699 C1 Canal !
G-3699 at G-3702
- BL03 Florida City Canal MIA101 !
G-3885 ! ! !!
997 "
J " J J S-165 # G-3701 GL03 S-21
- MIA104 " J MIA102
! ! G-3855 (COH-MW-trig-BS)
Goulds Canal G-3856 MIA103 (COH-MW-Sen)
! G-3162 !
S-166 MIA136 "
J PR03 S-21A FKS 9 S-196 J !! # Sec34-MW-02-FS
- Mow ry MIA137
! G-3700 ! G-3615 Canal 102 at
! SW 107 Ave S-196A S-167 !
25°30'
- near Sec34-MW-01-FS !! "
J MIA202 G-1180 ! G-1179 Homestead, FL G-3938 "
J "
J MI03 1 MIA203 TENNESSEE ROAD
! # MIA201 Military Canal 1 Can S-179 S-20G al (C-103) MW04 !
! Sec34-MW-03-FS
- ! ! S-20F# G-1264 Canal at G-3698 G-3698 FPL Turkey MIA225 G-3164 997 North Canal "! !
Point " MIA207 J "
J MIA206 "
J MIA204
! G-3936 J CEMEX-MW-03-FS G-3937 Nuclear !
! ACI-MW-15-BS J J" J! Power Plant MIA205 J Florida City Canal
! MIA208 " "
J MIA226 J ACI-MW-16-BS J MIA215 J "
J "
J J MIA209 MIA227 "
J MIA210 MIA230 J! ! "
J "
J ! "
J "
J J! "
J! "
J # !
J ""
J J G-3166 G-3939 "
J MIA214 MIA229 J "
J" S-178 ! "
J! "
J! "J "
J "
J ! G-3946 J
J J J "J" "
J 31 E G-613 # FPL Cooling MIA211 "
J " J MIA213F J MIA228 J
al L Canal System "
J Can "
J MIA212F J MIA233F SW 137 AVENUE MIA224 MIA236 MIA216 MIA232 "
J "
J " J "
J J" J Card Sound Road Canal FKS 5 MIA217 "
J MIA235F FKS 4 MIA223 MIA234 7.7 mi upstream from mouth "
J G-3940 G-3342 MIA221 S-20 !
J "
J " J # FKS 8 MIA231
! FKS 6 FKS 7 "
J MIA219F MIA222 MIA220 G-3167
! FKS 3 S-18C FKS 2 (plugged) al 25°20' ! ! "
an
- G-1256 J MIA218 dC FKS 1 d R oa OAD G-1603 1 un DR rd So OUN d un Canal C-110 Aer ojet a Ca RD S So Can FEC R CA rd Ca Canal C-109 al (C MO
-111
)
ilway CO NRO UN E
- TY S-197 Borrow Bar Ditch Sou nes nd Base from Miami-Dade County, South Florida Water Management 0 2.5 5 KILOMETERS and U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 0 2.5 5 MILES Figure 8. Locations of salinity monitoring sites, time-domain electromagnetic soundings, groundwater-level monitoring wells, and the mapped approximations of the inland extent of saltwater in the Biscayne aquifer in Miami-Dade and southern Broward Counties in 1955, 1995, and 2011. Enlarged version of this figure availabe for download at http://pubs.usgs.gov/sir/2014/5025/downloads/sir2014-5025_figure08large.pdf.
Origin of Saltwater Intrusion in Southeastern Florida 15
16 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Well field Sewage Cl/Br ratio = 300 to 800 Freshwater Biscayne Aquifer Limestone CaCO 3 Infiltration
+ + from tidal Quartz Sand SiO 2 Little or no ion exchange marshes seaward of the ion Freshwater exchange front inflow Freshwater/saltwater interface Ion exchange Leading edge front of saltwater Encroachment NaCl, B, Br, Leakage from front le t e d from ocean K, Li, SO 4 Dep Residual unprotected Mg along the base O4 HC O BS 3
saltwater canals Ca K e of the aquifer Li ativ ed Na
=C o n s er v Saltwater i ch C l , B r E nr Pinecrest sand member Quartz sand SiO 2 Figure 9. Conceptual diagram of sources and mechanisms of the saltwater that has intruded parts of aquifers in southeast Florida, and changes in water chemistry that may result from this intrusion.
because the flow gradient in the aquifer was primarily Effects of Urban and Hydrologic Development on toward the canal (Kohout and Leach, 1964, p. 36).
Saltwater Intrusion Conversely, when the water control structure was closed, the water that was in the canal inland of the dam, whether A goal of this study was to examine the environmental it was fresh or saline, was pushed horizontally outward into and anthropogenic causes of saltwater intrusion in the the aquifer. The potential exists, therefore, for intrusion of Biscayne aquifer in eastern Miami-Dade County and to the aquifer caused by any saltwater trapped upstream of delineate the resulting distribution of saltwater of various control structures. ages and sources. This goal was accomplished in part through The National Oceanic and Atmospheric Administration geochemical evaluations of recharge conditions and ages of (NOAA) estimates that mean sea levels at Ft. Myers, Key water in the aquifer. A detailed understanding of the history West, Miami Beach, Naples, and Vaca Key, Florida, have of saltwater intrusion provides a valuable framework for increased at rates of 0.24, 0.22, 0.24, 0.20, and 0.28 m per evaluating these geochemical results. The following sections 100 years, respectively (National Oceanic and Atmospheric provide a summary of predevelopment conditions and Administration, 2012). Relative increases in sea level may events leading to saltwater intrusion in the Biscayne aquifer.
exacerbate the encroachment of saltwater along the base of Detailed examinations of the history of urban and hydrologic the aquifer and the leakage of saltwater past salinity control development in the study area are provided by Fletcher (1911),
structures where it could potentially leak into the aquifer. Paige (1986), and Parker and others (1955).
Origin of Saltwater Intrusion in Southeastern Florida 17 35 30 25 Salinity, in practical salinity units 20 15 10 5
0 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 10. Salinity of the Biscayne Canal at station BS04, Miami-Dade County, Florida, 1988-2010.
Predevelopment Conditions at least some saltwater intrusion in this area, which may have been caused by inland flow of saltwater in coastal streams or Prior to development, the freshwater marshes of the overwashing of the coast during hurricanes or tropical storms.
Everglades covered approximately 3,000 km2 of Miami-Dade County, which is most of the land west of the Atlantic Coastal Ridge except for an area in northwestern Miami-Dade Relation of Urban Development to Saltwater County (figs. 2A and 3). Most of the southern and eastern Intrusion coastal parts of the county, approximately 1,030 km2, were covered with coastal marshes and mangrove swamps (fig. 3). Water levels in the Biscayne aquifer near Miami are Water levels in the Everglades near Miami are estimated estimated to be approximately 2.9 m below predrainage conditions based on a comparison of historical information to have been approximately 3 to 4.3 m above NGVD 29 and monitoring-well data (Parker and others, 1955, p. 580; (Shaler, 1890, p. 158; Parker and others, 1955, p. 581; Fish U.S. Geological Survey, 2011f), and this reduction in water and Stewart, 1991, p. 47). These water levels exceed the levels has resulted in saltwater intrusion in about 1,200 km2 of estimated minimum freshwater heads (0.6 to 1.5 m) necessary the Biscayne aquifer in Miami-Dade County as of 2011. The to prevent saltwater encroachment in the Biscayne aquifer. events that led to this intrusion began in December 1845 when Early residents and visitors describe numerous freshwater drainage of the Everglades was first proposed by the Florida springs, onshore near the coast as well as offshore in Biscayne State Senate (Paige, 1986, p. 138). Between 1850 and 1907, Bay (Fuller, 1904; Munroe and Gilpin, 1930; Parks, 1987). various Federal and State acts were passed to facilitate Water levels were sufficiently high prior to development in drainage of the Everglades, and these acts provided authority this area to maintain freshwater in the Biscayne aquifer close and resources for the installation of numerous drainage canals.
to the coast (Parker, 1945). Although the current study did The Miami Canal (table 1; fig. 11) installed beginning in 1908, not identify any historical information directly describing was one of the first canals in south Florida. Concrete locks and the extent of saltwater intrusion in the southernmost parts of dams that might have helped reduce saltwater intrusion were Miami-Dade County prior to drainage of the Everglades, the installed in 1912-13 in many of the canals; however, with a low land-surface altitudes in this area and the existence of few exceptions, these locks and dams typically were poorly coastal saltwater marshes indicate that there may have been maintained and operated (Parker and others, 1955, p. 587).
18 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 1. Partial history (1881-1978) of canal, structure, and levee installations in south Florida.
[km2, square kilometers; ?, date uncertain; -, no data]
Begin End Feature year year 1881 1896 First canals to drain 400 km2 near lake Okeechobee.
1906 1909 Launching of publicly funded dredge ships, Everglades, Okeechobee, Caloosahatchee, and Miami.
1908 1932 Dynamiting of the Miami Rapids, dredging of the Miami Canal.
1910 - Small 2-m-high earth dike built along part of the southern shoreline of Lake Okeechobee.
1912 1917 Florida City (C-105), Snake Creek (C-9), and Snapper Creek (C-2) Canals.
1919 1928 Tamiami Canal dredged as far west as the L-28 canal.
? 1922 The Model Land (C-107 and C-107S), North (C-104), and Goulds (C-101) Canals.
1922 - Enlarged Lake Okeechobee dike.
1925 1928 Biscayne (C-8) and Little River (C-7) Canals.
1925 1934 Completion of the Comfort Canal.
1925 1927 many small canals in Miami-Dade County.
1930 1938 Herbert Hoover Dike installed at Lake Okeechobee.
1942 1945 Replacement of first water control structure on Miami Canal by a pneumatic dam. This failed in 1945 and was in turn replaced by a sheet pile structure.
? 1945 Initial Military, Mowry (C-103) canals and FEC Railroad and Card Sound Road borrow ditches.
1945 1946 Sheet pile salinity control structures installed on Coral Gables, Little River, Snapper Creek, Snake Creek, and Tamiami Canals.
1950 1960 Levee system on the western side of the urban development, L-30, L-31N, and L-33 Canals, extension of Little River Canal (C-7), Snake Creek (C-9), and Snapper Creek (C-2) Canals, and installation of salinity control structures S-22, S-27, and S-29.
1960s - Expansion of Herbert Hoover Dike.
1960 1968 Aerojet (C-111), Belle Air (C-1N), Black Creek (C-1), Cutler Drain (C-100), L-31E, L-67, and Princeton (C-102) Ca-nals and extension of Biscayne Canal (C-8), Little River (C-7), Mowry (C-103), L-31N Canals, installation of salinity control structures S-20, S-20F, S-21, S-21A, S-28, S-123.
1970 1978 C-109, and C-110 Canals, expansion of Card Sound Road Borrow Ditch to create The Card Sound Road Canal (C-108).
Installation of salinity control structures S-26, S-25B, S-25, S-25A, and S-336. C-109 and C-110 not fully completed.
In addition to the drainage caused by canals, withdrawals The control structure leaked considerably, and it had a gate from the aquifer for public, residential, and industrial water that had to be periodically lifted to allow the passage of supply increased as population increased (table 2). The first barges. It was eventually replaced by better structures. The public supply wells were installed in 1899. The well drilled Coconut Grove well field began to yield saltwater in 1933 and closest to the Miami River became saline within about a year. had to be abandoned in 1941. A USGS study by Cross and The Spring Gardens well field was installed in 1907 as a Love (1942) indicated that (1) saltwater had intruded 3.2 km replacement for the first public supply wells, but it started to inland into the Biscayne aquifer and several kilometers farther become saline in 1919 and was replaced by new well fields in inland along the Miami Canal, (2) saltwater was leaking from Miami Springs and Coconut Grove in 1924 and 1925, respec- the canals and encroaching along the base of the Biscayne tively (fig. 1, table 2) (Parker and others, 1955, p. 705; South aquifer, (3) groundwater levels near the Miami Canal were Florida Water Management District, 2010). By 1942 nearly below nearby canal stages and were drawing saltwater into 10,000 domestic, public, and industrial water supply wells the aquifer, and (4) two small lakes that were open to the had been installed in Miami-Dade County; these wells ranged Miami Canal had become saline, and this saltwater seeped into in depth from a few meters to 37 m or more (Cross and the aquifer where it flowed downgradient toward the Miami Love, 1942, p. 490). Springs well field.
In 1938-1939 a major drought (fig. 4) exacerbated the Parker and others (1955, p. 589-680) write that during effects of changes in the hydrologic system. Some of the wells the 1943-46 drought, saltwater migrated at least 6 km inland in the Miami Springs and Hialeah well fields nearest to the from the mouths of all of the canals, except possibly the Miami Canal, and numerous private water supply wells near Goulds and Mowry Canals, which were not sampled farther tidal canals, began to become saline (Parker and others, 1955, inland. In eight of these canals, saltwater migrated 11 to 20 km
- p. 587-691). To protect the well fields, a water control inland. Between 1944 and 1945, freshwater runoff ceased structure was installed in the Miami Canal in 1939 (fig. 12). in several of the shorter canals, and highly saline water was
Origin of Saltwater Intrusion in Southeastern Florida 19 Table 2. Partial history (1899-2001) of well field installations and operations in Miami-Dade County, Florida.
[-, no data]
Begin year End year Feature 1899 - First city of Miami public water supply wells.
1907 1919 Installation and modifications to the Spring Gardens well field.
1919 - Spring Gardens Well Field began to yield salty water.
1924 - Installation of the lower Miami Springs well field (8 wells) as a replacement for the Spring Gardens well field.
1925 1937 Installation (initially two wells) and subsequent modification of the Coconut Grove well field.
1933 - Coconut Grove well field first became salty.
1936 1954 Installation of Upper Miami Springs well field (4 wells), expanded in 1945, 1949, and 1954 (total of 12 wells).
1936 - Installation of Hialeah well field (three wells).
1941 - Coconut Grove well field had to be abandoned because of saltwater encroachment.
1942 - By this year, an estimated 10,000 domestic, public, and industrial water supply wells had been installed.
1949 1964 Installation of Alexander Orr well field (4 wells) expanded in 1952 and 1964 to total of 10 wells.
1953 1971 Installation of Leisure City well field.
1953 1997 Installation of Southwest well field.
1966 1972 Installation of Preston well field.
1975 - Installation of Medley and Naranja well fields.
1976 1982 Installation of Snapper Creek and Northwest well fields.
2000 2001 Installation of the Newton well field.
Figure 11. Rapids of the Miami River prior to their destruction by Figure 12. First water control structure on the Miami Canal dynamiting to increase drainage of the Everglades. From Smith, installed in December 1939. This structure leaked considerably 1909. Courtesy of History Miami Archives and Research Center. and also was opened to allow barges to pass. Photograph from the files of the U.S. Geological Survey.
20 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater observed entering the ground with visible velocity (Parker been relatively minor compared to the changes that occurred and others 1955, p. 630). Parker and others (1955, p. 589-590) between 1904 and 1946 (Parker and others, 1955, p. 589, indicated that during 1943 to 1946 the greatest advance of fig. 169; Renken and others, 2005a, figs. 53-55).
saltwater encroachment occurred in the Biscayne aquifer.
They found that in a 27-month period between 1943 and 1944 saltwater encroached landward by 610 m, which was a rate of 270 meters per year (m/yr). Data Collection and Analysis In 1945, having received the authority to control water levels in canals within its boundaries through a legislative Site location and construction information for sites act, Dade County (currently named Miami-Dade County) used to evaluate the inland extent of saltwater or the causes began to install numerous salinity control structures that of saltwater intrusion in the Biscayne aquifer is provided were effective in controlling salinity (Parker and others, in appendix 1. Monitoring results from a few of these sites 1955, p. 589). During the 1950s and 1960s, additional canals are provided in this report. Monitoring results from the and more technologically advanced control structures were remaining sites are available from the USGS Annual Water built with the dual purposes of preventing extensive flooding Data Reports and National Water Information SystemWeb by allowing sufficient drainage during tropical storms and interfaceWater quality samples for the Nation websites maintaining freshwater heads sufficient to prevent further (U.S. Geological Survey, 2011e, f) or from the organiza-saltwater intrusion. During the first 2 years of the 1970 to tions listed in appendix 1. The results of 69 geochemical 1977 drought (fig. 4), however, saltwater in the Miami Canal samples and 3 replicate samples from 44 sites are provided upstream of salinity control structure S-26 came to within in appendix 2. Salinity profiles were collected in the Card 1.6 km of the Miami Springs and Hialeah (currently named the Sound Road Canal to evaluate the extent to which saltwater Hialeah-Preston) well fields (Benson and Gardner, 1974) and can flow inland along this canal (appendix 3). Information increased the salinity of samples from wells near the Miami concerning the TEM soundings is provided in appendix 4.
Canal (fig. 13). Although saltwater continues to leak past The methods used to develop TSEMIL datasets are provided many of the water control structures in Miami-Dade County, in appendix 5. A comparison of the depth of the base of the since the late 1970s, the chloride concentration in samples Biscayne aquifer to the models of TEM soundings is provided from monitoring wells near the Miami-Canal have decreased in appendix 6. To improve the saltwater monitoring network, (fig. 13), and the changes in the inland extent of saltwater have eight new monitoring wells (fig. 8) were installed during 2,500 EXPLANATION 1943 1949 1960 1970 1980 1984 2000 1984 Drought period to to to to to to and date(s) 1946 1957 1963 1977 1982 1990 Monitoring 2,000 wells G-355 Chloride concentration, in milligrams per liter G-548 G-1351 G-1354 1,500 Saltwater Saltwater upstream 1,000 upstream of S-26 of S-26 1970-77 1939-40 1943-45 500 0 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 Year Figure 13. Chloride concentration in samples from monitoring wells G-355, G-548, G-1351, and G-1354 near the Miami Canal and between 0.6 and 2.4 kilometers northwest of salinity control structure S-26, Miami-Dade County, Florida.
Data Collection and Analysis 21 this study, and a suite of geophysical logs were collected The Kemmerer captures a sample from the bottom of the well prior to completion of the wells. Information concerning the where salinity is likely the greatest.
installation of these eight monitoring wells and other data Each organization involved in the collection of salinity collected in these wells are included in appendix 7, and the data determined the constituents or parameters to be measured geophysical logs collected from these wells are provided in and how those parameters were reported. In some instances, appendix 8. The hydrostratigraphic analyses using information the same organization may have reported results differently from these new wells are included in appendix 9. Sampling through time. Chloride concentrations generally were methods, sample analyses, and quality assurance are described expressed as either milligrams per liter or parts per million of in appendix 10. Monthly measurements of salinity in canals chloride. Salinity was reported as practical salinity units and collected by the Miami-Dade County Permitting, Environ- also as parts per thousand. The salinity units are approximately mental, and Regulatory Affairs (M-D PERA; Maria Idia equivalent but cannot be directly converted without additional Macfarlane, Water and Sewer Department, written commun., information. These parameters are therefore reported in the March 7, 2011; Craig Grossenbacher, Miami-Dade County same units used by the organizations that provided the data.
Permitting, Environmental, and Regulatory Affairs, written Metric equivalents are provided where necessary.
commun., July 7, 2010) are provided in appendix 11.
Time-Series Electromagnetic Induction Logging Salinity Measurements In Miami-Dade County, salinity monitoring wells have Salinity data from about 2,000 active or inactive sites been installed with polyvinyl chloride (PVC) casings and annular within the study area were available for evaluation of the inland seal materials that do not impede the induction of electromag-extent of saltwater. Most of these sites, however, were not netic energy in the aquifer. EMI logs, which consist of measure-close enough to the saltwater front, or at the necessary depth, ments of the bulk conductivity or resistivity of earth materials to aid in mapping the saltwater front. Numerous sites also throughout the depth penetrated by the wells, can be collected in were sampled by local and regional organizations. Only those these wells. The radius of investigation is 20 to 100 centimeters actively monitored sites that were used to map the saltwater (cm) from the center of the borehole (McNeill and others, 1990, front are included in appendix 1 and shown in figure 8. p. 1). The freshwater-saturated sand and limestone sediments In some areas, long open-interval wells were the of the Biscayne aquifer generally have relatively low bulk only wells available. Studies in Miami-Dade County and conductivities (10 to 30 millisiemens per meter [mS/m]), but elsewhere have determined that fresh and saltwater within where the sediments have been intruded by saltwater, bulk the open intervals of long open-interval wells may mix conductivity is higher. Therefore, EMI logs can be used to (Kohout and Hoy, 1963; Oki and Presley, 2008; Shalev and identify the depths at which saltwater occurs in the aquifer.
others, 2009). The Biscayne aquifer has been shown to have Moreover, because EMI measurements can be collected through cyclostratigraphic layers with three alternating forms of PVC casing, the possibility of ambient vertical borehole flow can porosity (Cunningham and others, 2006b), and some of the be eliminated. In south Florida, the USGS began to collect EMI layers have been shown to be laterally extensive. As a result, logs from short-screened PVC-cased monitoring wells in 1995.
natural head differentials can exist between these layers. Open Table 3. Vertical flows measured in open boreholes prior to well boreholes that pierce layers with head differentials can allow installation, 2009-2011, Miami-Dade County, Florida.
ambient vertical flow within the borehole. Geophysical logs collected in the boreholes of wells installed during this study [L/min, liters per minute; m, meter; -, no data]
near the edge of the saltwater interface in the Biscayne aquifer confirm the occurrence of extreme variations in porosity and Maximum Depth of Maximum Depth of vertical ambient flow within the borehole. Heat pulse flowmeter Local up-hole maximum down-hole maximum measurements collected in the boreholes of six of the eight identifier flow rate up-hole flow rate down-hole flow new wells (G-3885, G-3886, G-3887, G-3888, G-3947, and (L/min) flow (m) (L/min) (m)
G-3949) indicated maximum up-hole or and down-hole vertical G-3885 0.45 16.8 0 -
flow rates of 2.31 and -5.45 liters per minute (L/min) (table 3)
G-3886 2.31 16.5 -0.72 22.9 respectively. These flow rates indicate that certain types of samples and measurements from long open-interval wells in the G-3887 1.4 15.2 0 -
Biscayne aquifer may not be representative of the aquifer. G-3888 1.48 14.2 0 -
If long open-interval wells were the only wells available G-3946 0.15 12.6 0 -
in some areas, data collected from them were used to determine if the saltwater interface occurred in a well. A G-3947 0 - -5.45 31.7 to 36.0, non-isokinetic thief sampler called a Kemmerer (Lane and 38.1 to 39.3 others, 2003, p. 33-34) was used by the USGS to sample G-3948 0 - 0 -
long open-interval wells to minimize the mixing that could G-3949 0.42 25.9 0.04 -
be caused when the well is pumped (Kohout and Hoy, 1963).
22 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A time series of EMI logs can provide a detailed understanding limitation of induction logging equipment to provide a full of the movement of saltwater through the Biscayne aquifer that response to hydrostratigraphic layers thinner than 4 m (Taylor would not be possible using other methods. and others, 1989).
The current study used EMI logs that had been collected in 35 wells in Miami-Dade County. Some of these wells were logged only once, but sets of EMI logs that were collected Time-Domain Electromagnetic Soundings annually or semiannually are available for the majority of TEM soundings are surface geophysical measurements these wells. The EMI logs were used to (1) provide informa-that have been used extensively in south Florida since 1994 to tion about the thickness of saltwater occurring in the Biscayne evaluate the inland extent of saltwater in the Biscayne aquifer aquifer, (2) evaluate TEM sounding models, (3) calibrate (Sonenshein, 1997; Fitterman and others, 1999; Hittle, 1999; the HEM survey, and (4) provide insights into occurrence of Schmerge, 2001; Stewart and others, 2002) and to aid in the saltwater in the aquifer. As part of the current study, a meth-calibration and interpretation of results from a December odology was developed to process individual EMI logs into 1994 HEM survey in the Everglades (Fitterman and Deszcz-a TSEMIL dataset that was used to evaluate relatively small Pan, 1998). Seventy-nine TEM soundings were collected temporal changes in bulk conductivity (appendix 5).
during 2008 and 2009 to aid in mapping the inland extent of Many of the older wells, from which TSEMIL datasets saltwater in the Biscayne aquifer and to provide information were collected, do not penetrate beyond the base of the Biscayne to calibrate the HEM survey (fig. 8, appendix 4). Detailed aquifer; therefore, if saltwater did occur below the base of the information and the final models developed for each of these aquifer, it was not shown by these logs. The thickness of the TEM soundings are provided in Fitterman and Prinos (2011).
saltwater wedge determined with TSEMIL datasets is therefore Additional information concerning the TEM method in general based on the thickness of the saltwater lens within the Biscayne is provided by Kaufman and Keller (1983), Fitterman (1989),
aquifer itself. Although figures showing TSEMIL datasets are McNeill (1990), and Fitterman and Labson (2005).
not provided in this report for all sites where they were used, these datasets are readily available in the USGS online Annual Water Data Reports (U.S. Geological Survey, 2011e). HEM Survey Analysis The 2001 HEM survey processed during this study Comparison of Bulk Resistivity to Specific provided much more detailed information concerning the Conductance of Water and Chloride extent of saltwater than previously existed in the Model Land Concentration area (fig. 1). The Model Land area in southeast Miami-Dade County, south of the Florida City Canal and east of U.S.
EMI logs collected by the USGS in Miami-Dade County Highway 1, is the location of a wetland restoration project.
(U.S. Geological Survey, 2011e) indicate that freshwater- The survey area covered about 115 km2 of the southernmost saturated materials of the Biscayne aquifer typically vary in part of the study area (fig. 1). The survey consisted of densely bulk resistivity from approximately 35 to 220 ohm-meters spaced frequency-domain electromagnetic (FEM) measure-(ohm-m) and have an average bulk resistivity of approxi- ments collected using an instrument package suspended 30-m mately 80 ohm-m. Data from EMI logs and water samples below a helicopter. Measurements were collected by passing collected during the spring of 2009 from the Biscayne aquifer a sinusoidally varying current through multi-turn transmitter in Miami-Dade County were used to establish a relation coils. Five horizontal coplanar coil pairs operating at nominal between the bulk resistivity of the formation (including the frequencies of 400, 1,500, 6,400, 25,000, and 100,000 hertz water and the rock) and the electrical resistivity of the water (Hz) were used. The conversion of these measured fields to (fig. 14) (Fitterman and Prinos, 2011). A relation between the apparent and differential resistivity is described in Fitterman chloride concentration in water samples and the resistivity of and others (2012). Resistivity-depth functions were obtained these water samples (fig. 15) (Fitterman and Prinos, 2011) was from a differential resistivity-depth analysis. These functions combined with the relation between bulk resistivity and water were used to create resistivity-depth-slice maps ranging resistivity to determine that parts of the aquifer saturated with in depth from 5 to 100 m. East-west and north-south cross saltwater (1,000 mg/L of chloride or more) would have forma- sections of resistivity that coincided with the flight lines tion resistivities of about 10 ohm-m or less. Bulk resistivities also were created. All of the cross sections and depth slices ranging between 10 and 15 ohm-m were considered indicative processed during the current study are provided in Fitterman of the mixing zone at the leading edge of saltwater intrusion and others (2012); figure 16 shows an example of the and the mapped extent of saltwater intrusion was plotted to be 30-m-depth slice.
very close to these measurements. The maps and cross sections indicate a relatively The relation between the bulk resistivity of the formation sharp transition zone where differential resistivity generally and the electrical resistivity of the water is affected by decreased from 70 to 35 ohm-m across a horizontal distance variations in porosity and lithology and by potential measure- of about 300 to 600 m (Fitterman and others, 2012). Based ment errors. One type of measurement error is caused by the on information from sampled monitoring wells and TEM
Data Collection and Analysis 23 100 Formation resistivity, in ohm-meters 10 y = 5.0751x R² = 0.9285 1
0.1 1.0 10.0 100.0 Water resistivity, in ohm-meters Figure 14. Relation between the resistivity of water samples collected in monitoring wells in Miami-Dade County, Florida, and the formation resistivity measured by electromagnetic induction logs in the screened intervals of the same well.
Measurements symbolized by open circles were not used for the regression.
100 y = 310.2x-0.704 R2 = 0.9695 Water resistivity in ohm-meters 10 1
0.1 10 100 1,000 10,000 Chloride concentration, in milligrams per liter Figure 15. Relation between water resistivity and chloride concentration in water samples from monitoring wells in Miami-Dade County, Florida. From Fitterman and Prinos (2011).
24 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 8030'00" 8022'30" Sec34-MW-02-FS Sec34-MW-01-FS MIA201 MIA203 MIA202 G-1264 G-3164 MIA225 MIA206 Sec34-MW-03-FS MIA207 MIA205 MIA204 MIA208 CEMEX-MW-03-FS MIA215 MIA209 MIA229 G-3166 MIA210 MIA226 MIA214 MIA230 MIA227 G-3946 MIA211 MIA228 MIA213F MIA236 MIA234 MIA212F FKS 8 MIA231 MIA233F 27.4 E
L-31 MIA232 MIA216 MIA235F MIA217 MIA223 MIA224 2522'30" FKS 7 G-3342 FKS 4
- 24. 4 FKS 5 MIA222 MIA220 MIA219F MIA221 CA RD SO UN FKS 3 DR OA D
FKS 2 G-1256 MIA218F 15.2 C-1 11 3
21.
EXPLANATION U.S. HW 18.3 Canal Inverted resistivity, Minor canals in ohm-meters Y. 1 Creek Powerline, large 100.0 Powerline, small 70.0 Base from U.S. Geological Survey digital data, Universal 0 1 2 KILOMETERS Transverse Mercator projection, zone 17N, NAD 83 Road 55.0 0 1 2 MILES Extent of saltwater intrusion 45.0 (ESI) in 2011 (Prinos, 2011). Dashed 35.0 where data are insufficient to 29.0 accurately locate Extent of saltwater intrusion in 18.0 1995 (Sonenshein, 1997). Dashed 12.0 where data are insufficient to 7.2 accurately locate 2.8 Depth below sea level to base of Biscayne aquifer, 1.7 in meters (Fish and Stewart, 1991) 1.1 MIA224 Time domain electromagnetic 0.5 sounding FKS 4 Well location and number Figure 16. Example of a depth slice from the 2001 helicopter electromagnetic survey, Miami-Dade County, Florida. Modified from Fitterman and others (2012).
Approximate Inland Extent of Saltwater in the Biscayne Aquifer 25 soundings collected in this area, this transition zone was the saltwater front has either advanced or retreated. These interpreted to be the saltwater interface. To determine the estimations are based on changes apparent in the monitoring inland extent of saltwater in the HEM survey area, the data, but are relatively coarse approximations because the 45-ohm-m differential resistivity contour of each of the depth relation between the amount of front movement and amount of slices was mapped. This map provided a three-dimensional change in salinity is variable.
representation of the saltwater interface. The intersection of The precision of the estimated inland extent of the this interface with the base of the Biscayne aquifer interpo- saltwater front depends on the availability of monitoring data lated from the map of Fish and Stewart (1991) was mapped and/or the geophysical spatial coverage. For example the and represents the inland extent of saltwater in the Biscayne Model Land area south of the Florida City Canal and east of aquifer in 2001. This information was used to create the 2008 U.S. Highway 1 had long been an area where little information preliminary map of the inland extent of saltwater intrusion in was available for mapping the inland extent of saltwater. As this area. Thirty-six additional TEM soundings collected in the a result, the inland extents of saltwater estimated by the maps spring of 2009 and 4 new wells were used to verify or update produced in 1955 and 1995 (fig. 8) differed in this area by 1 to the inland extent of saltwater in 2011 (fig. 8). 4 km. Spatial coverage in the Model Land area was greatly improved during the current study through the collection of numerous TEM soundings (Fitterman and Prinos, 2011),
the processing of the 2001 HEM survey (Fitterman and Approximate Inland Extent of others, 2012), and the installation of new monitoring wells.
Saltwater in the Biscayne Aquifer In this area, relatively dense surface geophysical coverage was possible because of the many large open fields that were The approximate inland extent of saltwater in the relatively free of anthropogenic interference.
Biscayne aquifer (appendix 12) was determined by using Surface geophysical measurements also improved spatial (1) salinity measurements of groundwater and surface water coverage elsewhere in Miami-Dade County, particularly where (chloride, total dissolved solids [TDS], or specific conduc- one measurement occurred on one side of the interface and tance), (2) borehole EMI data, (3) TEM data, and (4) HEM another occurred on the opposite side. Unfortunately, surface survey data collected in 2001. The word approximate is geophysical measurements could not be collected everywhere used because the 1995 and 2011 maps are considered to because some areas were too heavily developed to allow the be approximations of the inland extent of saltwater. Where collection of surface geophysical data given the transmit coil chloride concentration information exists from wells that size required. In these areas, the distance between monitoring fully penetrate the aquifer, the mapped line represents the wells ranges from 0.5 to 5 km. The approximate extent of approximate position of the 1,000-mg/L isochlor at the base saltwater intrusion is less reliable in areas where monitoring of the Biscayne aquifer. Where constrained by EMI logs or wells are widely spaced and surface geophysical measure-ments could not be made.
TEM soundings, this line represents the landward limit of the Most of the time-series data used to evaluate movement occurrence of aquifer materials (including water) measured of the saltwater front were collected by the USGS and are or modeled to have a bulk resistivity of less than 10 ohm-m.
readily available online (U.S. Geological Survey, 2011e, Resistivities between 10-15 ohm-m are considered indicative 2011f, 2011g). It is not feasible to include all of these data in of the mixing zone at the leading edge of the saltwater front.
this report, but examples of the changes in chloride concentra-Resistivities greater than 15 ohm-m indicate freshwater tion that have occurred are shown in figure 18. Examples saturated materials.
of the TSEMIL datasets are provided in the Time-Series Elec-tromagnetic Induction Logging section of this report. Results Improved Spatial Coverage and Precision of the of all TEM soundings used to map the location of the saltwater Inland Extent of Saltwater front are published in the companion report (Fitterman and Prinos, 2011; appendix 4).
Mapped changes of the inland extent of saltwater between 1995 and 2011 (fig. 17) are the result of improved Changes between 1995 and 2011 spatial information, actual movement of the saltwater front, or a combination of both. The water-quality measurements and The saltwater front was mapped farther inland in 2011 samples and geophysical information collected or processed than in 1995 (figs. 8 and 17) in eight approximated areas during this study provided better spatial coverage than had totaling 24.1 km2. These eight areas are (1) a 4.5-km2 area in existed in 1995 when the extent of saltwater was last mapped. northern Miami-Dade and southern Broward Counties from This was particularly true in the Model Land area where there just south of the Biscayne Canal to the city of Hallandale was insufficient information available to accurately determine Beach, (2) a 3.2-km2 area near Interstate 95, extending from the inland extent of saltwater in 1995 (Sonenshein, 1997). north of the Little River Canal to Interstate 195, (3) a 2.0-km2 Estimated advances or retreats of the saltwater front are area from the Miami Canal to a little south of the Comfort provided in areas where existing information indicates that Canal, (4) a 1.2-km2 area between SW 8 Street (Tamiami
26 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 80°30' 80°20' 80°10' 95 820 "
L-33 7 HOLLYWOOD 26°00' 67A L- L-67 HALLANDALE C
75 BEACH "
BROWARD Snake Creek Ca COUNTY n al MIAMI-DADE 997 (C
-9 COUNTY
)
821 826 Biscayne Canal (C
-8)
L-30 Little River Canal 9 M "
iam i HIALEAH 25°50' an C MIAMI al SPRINGS "
(C 195
-6 NW 36 STREET )
836 Comfort Canal "
Tamiami Canal (C-4) MIAMI SW 8 STREET OCEAN COCONUT (TAMIAMI TRAIL)
GROVE "
ATLANTIC SW 72 STREET (SUNSET DRIVE)
Snapper SW 104 STREET Creek (KILLIAN PARKWAY) 25°40' Canal PINECREST (C-2)
Florida Turnpike SW 72 AVENUE L-31N SW 136 STREET (HOWARD DRIVE)
SW 184 STREET (EUREKA DRIVE) 1
" CUTLER BAY Pri SW 200 STREET (CUTLER RIDGE DRIVE) nce Goulds Canal ton Canal (C-102)
SW 288 STREET (BISCAYNE DRIVE)
M Bay ow 25°30' ry ne Cana cay l (C-103) EXPLANATION HOMESTEAD "
Bis North Canal Origin and delineation of saltwater intrusion and Florida City Canal basis for modifications to mapped extent SW 344 STREET (PALM DRIVE)
FLORIDA Historical leakage of saltwater from canal. Chloride CITY content estimated to be less than 1,000 milligram SW 137 AVENUE per liter and gradually dissipating 1
MODEL TENNESSEE ROAD LAND FPL Cooling Advance of the saltwater front since 1995 Form Modal Land Canal Canal System Retreat of the saltwater front since 1995 SO Ae (C-107) ro l
je a
RD t
C-110 an Recent leakage of saltwater from canal CA C
Canal (C-111) o ad Ditch Landward revision of saltwater front based on dR D
UN orrow 25°20' un new information So way B AD C Rail rd RO nd ou Seaward revision of saltwater front based on Ca of FE S
ation ard new information er loc C
Previously intruded as of 1995 C-109 (plugged)
Approximate inland extent of saltwater in 2011.
Bar Dashed where information was insufficient n
Sou es for an accurate estimate nd Base from Miami-Dade County, South Florida Water Management 0 5 10 KILOMETERS and U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 0 5 10 MILES Figure 17. Origin and delineation of saltwater intrusion in the Biscayne aquifer and the basis for modifications to its mapped extent. Enlarged version of this figure available for download at http://pubs.usgs.gov/sir/2014/5025/downloads/sir2014-5025_figure17large.pdf.
Approximate Inland Extent of Saltwater in the Biscayne Aquifer 27 6,000 700 5,000 G-1179 600 G-896 500 4,000 400 3,000 300 2,000 200 1,000 100 0 0 12,000 120 10,000 G-3699 100 G-3603 Chloride concentration, in milligrams per liter Chloride concentration, in milligrams per liter 8,000 80 6,000 60 4,000 40 2,000 20 0 0 6,000 2,500 5,000 G-1264 2,000 G-3605 4,000 1,500 3,000 1,000 2,000 1,000 500 0 0 2,500 2,500 2,000 G-3229 2,000 G-3698 1,500 1,500 1,000 1,000 500 500 0 0 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 Year Year 4,000 3,500 G-894 Chloride concentration, in milligrams per liter 3,000 2,500 2,000 1,500 1,000 500 0
1,600 1,400 G-3162 1,200 1,000 800 600 400 200 0 1950 1952 1954 1956 1958 1960 1962 1964 1966 1968 1970 1972 1974 1976 1978 1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 Year Figure 18. Chloride concentrations in water samples from long-term monitoring wells (see fig. 8 for well locations).
28 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Trail) and the Coral Gables Canal, (5) a 0.5-km2 area in the the TEM soundings collected in 2008 and 2009 (Fitterman and city of Pinecrest between SW 104 Street (Killian Parkway) Prinos, 2011), the HEM survey collected in the Model Land and SW 136 Street (Howard Drive), (6) a 0.3-km2 area in the (Fitterman and others, 2012), a HEM survey in the Everglades city of Cutler Bay, between SW 184 Street (Eureka Drive) and National Park and surrounding areas (Fitterman and Deszcz-SW 200 Street (Cutler Ridge Drive), (7) a 7.1-km2 area in or Pan, 1998, 2002), and new monitoring wells installed during near the cities of Florida City and Homestead, extending from this study by EAS Engineering, Inc., Florida Power and Light a little south of the Military Canal to a little south of FKAA (FPL), Miami-Dade County, and the USGS. Decreases in the well G-1264 (fig. 8), and (8) a 5.3-km2 area south of Florida chloride concentrations in wells G-896 and G-1179 (fig. 18)
City in the vicinity of U.S. Highway 1 and Card Sound Road. indicate that some of the change in the mapped position of the In most of these areas, the difference between mapped extent front near these wells resulted from movement of the front, of saltwater in 1995 and 2011 is likely caused by improved rather than from improved spatial coverage alone.
spatial coverage or a combination of advances of the saltwater front and improved spatial coverage. Landward movement of the front is inferred from increases in the chloride concentra-tion in water samples or increases in the bulk conductivity Characterization and Distribution of of EMI logs from monitoring wells used for this evaluation Saltwater in the Biscayne Aquifer (fig. 8, appendixes 1 and 5). Examples of the increases in the chloride concentrations in samples are shown in figure 18. Water managers need to understand the origin of intruded In two areas, the differences between the 1995 and saltwater and the temporal and spatial changes in its distribu-2011 maps are likely caused solely by front movement. In tion to evaluate the potential for saltwater intrusion at coastal the area between SW 8 Street and the Coral Gables Canal, well fields. Saltwater that intruded early in the 20th century analysis of water samples from well G-3229 (figs. 8 and 18) and is gradually dissipating may pose less of a concern, for indicated an increase in chloride concentration from about example, than saltwater that is actively leaking from a canal 600 mg/L to 1,640 mg/L between December 1996 and near a well field. If the sources of saltwater are misidentified, September 2011 (fig. 18). The saltwater front, which had been the corrective measures implemented to prevent saltwater approximately 60 m southeast of well G-3229 in 1995, had intrusion could fail to address the actual issue. Differentiating moved 230 m farther inland by 2011. Near Florida City and between saltwater that previously intruded the aquifer and Homestead near SW 344 Street (Palm Drive), the saltwater saltwater that is actively intruding can be difficult because front had been mapped about 0.5 km east of well G-3699 saltwater of various origins and ages may mix.
(fig. 8) in 1995. This well was installed in 1999, and the first Water samples were analyzed to determine (1) major chloride concentration sampled was 950 mg/L. The chloride and trace ion geochemistry, (2) strontium isotopic ratios, concentration in samples had increased to 9,700 mg/L by (3) oxygen and hydrogen stable isotopic ratios, (4) tritium 2011, and monitoring wells G-3855 and G-3856 located west concentrations, (5) 3H/3He concentrations, (6) sulfur hexafluo-of well G-3699 have become saline. Based on this informa- ride concentrations, and (7) dissolved gas concentrations. The tion, the saltwater front was mapped to be about 1.4 km west concentrations of 3H/3He and sulfur hexafluoride were used to of well G-3699 and is interpreted as having advanced by interpret the ages of water samples. These analyses, coupled about 1.9 km between 1995 and 2011 near SW 344 Street. with other types of information, were used to evaluate the Water samples from wells G-1264 and G-3698 located prevailing climatic conditions during which saltwater intruded south and north of well G-3699, respectively, also indicated the Biscayne aquifer, timeframes for this intrusion, and the increases in chloride concentration during this same period chemical interactions between the intruded saltwater and (fig. 18), and the front appears to have advanced landward the aquifer.
in this area. The changes occurring in the vicinity of wells G-1264, G-3698, and G-3699 are described in greater detail in subsequent sections of this report. Major and Trace Ion Geochemistry The saltwater front was mapped closer to the coast in 2011 than it was in 1995 (figs. 8, 17) in four approximated Ions, such as chloride and bromide, are conservative areas totaling about 6.2 km2. These areas are (1) a 0.7-km2 area indicators of freshwater and seawater mixing because between the cities of Coconut Grove and Pinecrest extending these ions generally do not adsorb or interact with aquifer from SW 72 Street (Sunset Drive) to SW 104 Street (Killian materials. The concentrations of many other ions, however, Parkway), (2) a 2.7-km2 area south of the city of Cutler Bay are affected by dissolution of aquifer materials, precipitation extending from SW 200 Street (Cutler Ridge Drive) to a little or reduction of chemical species, and adsorption onto or south of SW 288 Street (Biscayne Drive), (3) a 0.1-km2 area release from clay minerals, organic matter, oxyhydroxides, in the Model Land between SW 137 Avenue and Tennessee or fine-grained rock materials as mixing occurs, (Jones and Road, and (4) a 2.7-km2 area south of Florida City, between others, 1999, p. 61). These complex chemical changes occur U.S. Highway 1 and the C-111 Canal. The changes were iden- in a portion of the saltwater front called the ion-exchange tified based on improvements in spatial coverage provided by front (fig. 9), and may include exchange of sodium in
Characterization and Distribution of Saltwater in the Biscayne Aquifer 29 seawater with adsorbed calcium; adsorption of potassium, The concentrations of chloride and bromide generally boron, and lithium in seawater onto clay minerals (Jones and plot near the theoretical freshwater/seawater mixing line others, 1999, p. 66); enrichment in calcium and bicarbonate because these ions are conservative indicators of freshwater caused by dissolution of calcite and aragonite in carbonate and seawater mixing, and generally are not adsorbed by, or aquifers (Richter and Kreitler, 1993, p. 107; Jones and others, interact with, aquifer materials. As expected, the chloride and 1999, p. 61); reduction of the sulfate in seawater to hydrogen bromide concentrations in samples collected during the study sulfide under low redox conditions in the aquifer (Richter all plot close to the theoretical freshwater/seawater mixing and Kreitler, 1993, p. 107; Jones and others, 1999, p. 67); line (fig. 20). Concentrations of boron, magnesium, potassium, and exchange of calcium adsorbed on clay minerals with sodium, and sulfate were frequently depleted (figs. 21-25),
magnesium in seawater (Howard and Lloyd, 1983, p. 435; whereas the concentrations of calcium were frequently Richter and Kreitler, 1993). Causes for enrichment of barium enriched (fig. 26), relative to the theoretical freshwater/
seawater mixing line. The extent of depletion and enrichment in the freshwater/seawater mixing zone include desorption of varied and may indicate either the arrival of the saltwater surface-bound barium from aquifer particulates by replace-interface (sites highlighted in yellow) or the occurrence of ment with major seawater cations, and diagenetic reactions prior intrusion (sites highlighted in blue). Unlike the evalua-such as dissolution of authigenic barite, decomposition of tion of the Ca/(HCO3 + SO4) ratios, which was based on ratios barium-rich organic material, and dissolution of barium greater than or less than 1, comparisons of ion concentra-containing metal oxide phases (Shaw and others, 1998). tions to the theoretical freshwater/seawater mixing line are Richter and Kreitler (1993) state: These changes are most somewhat more subjective.
pronounced within the initial sea-water front that mixes Many of the wells from which samples had with fresh water. Subsequent intrusion deviates little from Ca/(HCO3 + SO4) ratios greater than 1 also were among the sea-water composition. wells most depleted in boron, magnesium, potassium, sodium, The ionic exchanges that occur as seawater mixes with and sulfate and most enriched in calcium relative to the theo-freshwater are indicated by deviations from the theoretical retical freshwater/seawater mixing lines. This group of wells freshwater/seawater mixing line that would be created solely includes G-3615, G-3698, G-3699, G-3704, and G-3855.
by mechanical mixing of freshwater and seawater (Howard Barium was enriched relative to the theoretical freshwater/
and Lloyd, 1983); the seawater end member for the mixing seawater mixing line (fig. 27) in four wells (G-3699, G-3615, line was taken from Turekian (1976), whereas the freshwater G-3704, and G-3855) that were more depleted in boron, end member was generally the average composition of water sodium, sulfate, magnesium, and potassium and more enriched samples collected from canals during this study. Seaward in calcium than most of the other wells. Similar patterns of of the ion-exchange front or at depths that are well below major ion concentrations were found in well G-1264 (with the freshwater/saltwater interface, there may be little or no the exception of boron, which was not measured), and well ion exchange because exchange sites of aquifer materials G-3705 (with the exception of sulfate). The described enrich-may be saturated and chemical equilibrium of seawater with ments and depletions relative to the theoretical freshwater/
aquifer materials may have been established. Where ion seawater mixing lines indicate ion exchanges that are typical exchange is not occurring, the concentration of ions in water of the arrival of saltwater intrusion. Concentrations of major samples should plot on the theoretical freshwater/seawater ions in wells FKS4, FKS8, G-939, G-3600, G-3601, G-3602, mixing line. G-3604, and G-3605 were less depleted and generally plotted A calcium to (bicarbonate + sulfate) molar ratio closer to the theoretical freshwater/seawater mixing lines than the concentrations of major ions in other wells, indicating that
[Ca/(HCO3 + SO4)] greater than 1 has been used to identify these wells are in areas where the aquifer materials are closer the arrival of saltwater intrusion at a given location in to equilibrium with seawater. Generally this is because the the aquifer where ion exchange results from the mixing of saltwater front has moved well inland of the locations of these freshwater and saltwater (Jones and others, 1999). Using this wells, but in some areas the situation is more complex (see, for criterion, the arrival of saltwater intrusion is indicated at example, the Miami and Tamiami Canals section of this report).
11 sites (wells G-901, G-1264, G-3615, G-3698, G-3699, Chloride to bromide (Cl/Br) mass ratios can be used to G-3704, G-3705, G-3855, G-3946D and one of each differentiate between rainfall (ratios of 50 to 150), shallow of the samples collected from wells F-279 and G-3701) groundwater (ratios of 100 to 200), and sewage effluent (ratios (table 2-1; fig. 19). A Ca/(HCO3 + SO4) molar ratio less than of 300 to 800) (Davis and others, 1998). Seawater has a Cl/Br 1 and a chloride concentration of 1,000 mg/L or more (fig. 19) mass ratio of about 288 to 297 (Turekian, 1976; Richter and indicated previous saltwater intrusion at 10 sites (wells FKS4, Kreitler, 1993, p. 28; Vengosh and Pankratov, 1998; Jones FKS8, G-939, G-3600, G-3601, G-3602, G-3604, G-3605, and others, 1999, p. 70). The Cl/Br mass ratio of most of the G-3609, and G-3702). Some sample results may be interme- groundwater-well samples ranged from 178 to 305, which diate between these conditions because the saltwater front may is close to the typical range for freshwater saturated and have passed the location, but some ion exchange sites may saltwater intruded groundwater. The Cl/Br mass ratio of most have remained available. of the canal water samples ranged from 235 to 304; likely a
30 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 3.0 2.8 EXPLANATION G-1264 Theoretical freshwater/seawater 2.6 mixing line Arrival of saltwater intrusion 2.4 Previously intruded 2.2 G-3855 Groundwater Calcium: (bicarbonate + sulfate) ratio Surface-water 2.0 G-3615 Seawater 1.8 G-3698 1.6 1.4 G-3705 G-3699 G-901 G-3704 1.2 G-3701 F-279 G-3946D 1.0 F-279 G-3609, G-3702 0.8 G-3856 G-3602 G-3605 0.6 G-939 FKS 4, G-3604 G-3601 G-3600 0.4 FKS 8 0.2 FKS 7, G-894, G-896, G-3603, G-3606, G-3607, G-3608, G-3610, G-3611, G-3700, G-3885 0
0 4,000 8,000 12,000 16,000 20,000 Chloride, in milligrams per liter Figure 19. Calcium to (bicarbonate + sulfate) ratio and the chloride concentration in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida. The composition of seawater used for this figure was described by Turekian (1976).
80 EXPLANATION Theoretical freshwater/seawater 70 mixing line Groundwater samples Groundwater replicate samples 60 Surface-water samples Seawater Bromide, in milligrams per liter 50 G-3600 F-279, G-939, G-3615 40 G-3699 30 G-3704 20 G-3604 G-3602 10 G-33855 G-3605 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 20. Bromide and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
Characterization and Distribution of Saltwater in the Biscayne Aquifer 31 1,400 EXPLANATION Theoretical freshwater/seawater 1,200 mixing line G-36 Arrival of saltwater intrusion 00 Previously intruded Groundwater sample 1,000 Magnesium, in milligrams per liter Groundwater replicate samples Surface-water sample Seawater 800 600 FK S
FK 8 S G-36 8
99 400 G FK G-FK -360 S 4 36 99 S 4 4
F-279, G-3946D G-93 G- 9 93 G- G- 9 G-200 36 90 G-37 05 1 36 02 04 G-3801, G-3609 G-G-3856 G-38 12 G-3615 55 64 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 G-3698, G-3705 Chloride, in milligrams per liter Figure 21. Magnesium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
450 EXPLANATION 400 Theoretical freshwater/seawater mixing line Arrival of saltwater intrusion 350 Previously intruded G-Groundwater sample 36 00 Groundwater replicate samples Potassium, in milligrams per liter 300 Surface-water sample Seawater 250 200 150 FK S
4 FK S
8 100 G- G-3604 G- 93 3 36 9 G-05 69 G-3602 9 50 G-3704 G-3601 G-90 G-3856 1 F-279, G-3946 G-1264 G-3615 G-3855 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 G-3609, G-3698 G-3705 Chloride, in milligrams per liter Figure 22. Potassium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
32 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 12,000 10,000 8,000 00 Sodium, in milligrams per liter G-36 6,000 FK EXPLANATION S
8 Theoretical freshwater/seawater G-4,000 36 mixing line 99 FK Arrival of saltwater intrusion S
G-3602 4 Previously intruded G-37 F-279 04 Groundwater sample G-G-939, G-3615 36 2,000 04 G-3855, G-3946D G- Groundwater replicate samples 12 64 Surface-water sample G-3605 G-G-3601 90 Seawater 1 G-939 G-3698, G-3705 G-3615 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 23. Sodium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
5,000 EXPLANATION 4,500 Theoretical freshwater/seawater mixing line Arrival of saltwater intrusion 4,000 Previously intruded Groundwater sample 3,500 Groundwater replicate samples Boron, in micrograms per liter Surface-water sample 3,000 Seawater G-36 00 2,500 2,000 1,500 G-36 1,000 04 36 G-99 G-939 F- G-3602 500 G-3601 27 G-9 37 G-3856 G-3702 04 G-3855 0 G-3698 G-3615 0 G-3701 2,000 G-3609 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 G-3705 Chloride, in milligrams per liter Figure 24. Boron and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
Characterization and Distribution of Saltwater in the Biscayne Aquifer 33 3,000 EXPLANATION Theoretical freshwater/seawater mixing line 2,500 Arrival of saltwater intrusion Previously intruded Groundwater sample Groundwater replicate samples 2,000 Sulfate, in milligrams per liter G-3600 Surface-water sample Seawater 1,500 FKS 8 1,000 F-279, G-939, G-3946D FKS 4 G-3699 G-3604 500 G-3704 G-3601, G-3705 G-3602 G-3605 G-901 G-3856 G-3609 G-3855, G-3615 G-3615 G-3698 G-1264 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 25. Sulfate and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
800 700 G-3699 600 Calcium, in milligrams per liter G-1264 500 G-3855 G-3600 G-3615 G-3704 400 F-279 G-3946D FKS 8 300 G-3705 G-3602 EXPLANATION G-901 FKS 4 Theoretical freshwater/seawater G-3698 mixing line 200 G-3609 G-3604 G-939 Arrival of saltwater intrusion G-3605 Previously intruded G-3601 G-3856 Groundwater sample 100 Groundwater replicate samples Surface-water sample Seawater 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 26. Calcium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
34 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 400 EXPLANATION G-3704 Theoretical freshwater/seawater 350 mixing line Groundwater sample Groundwater replicate samples 300 Surface-water sample G-3699 Seawater Barium, in micrograms per liter 250 F-279 200 G-3855 G-3602 150 G-3701 G-3615 G-3609 G-939 G-3600 100 G-3604 G-3605 G-3601 G-3705 G-3698 50 G-3702 G-3856 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 27. Barium and chloride concentrations in samples.
result of the mixing of rainfall runoff with inflow from shallow analysis, but given their depths and locations, these wells also groundwater, as well as mixing of seawater in some instances. may be screened in the Tamiami Formation. The elevated The Cl/Br mass ratios in samples from wells F-45, G3600, silica concentration in samples from these four wells may have G-3603, G-3604, G-3607, G-3608, G-3610, G-3611 and resulted from relatively long residence times of water in the sites Canal C100A at SW 72 Ave, Canal at G-3698, C2 Canal quartz-sand-rich sediments of the Tamiami Formation.
at G-3608, C2 Canal 150 Ft Upstream of S-22, and C5 Canal at NW 32 Ct ranged from 306 to 682, which is within the range of sewage effluent (appendix 2, table 2-1). Strontium Isotope Age Dating A triangular-shaped theoretical freshwater/seawater Strontium isotopes were used to evaluate the origin of mixing area, within which most of the groundwater sample saltwater in the surficial and intermediate aquifer systems in results occur, is defined by the maximum and minimum silica southwest Florida (Schmerge, 2001). Strontium isotope age and chloride concentrations in surface water, and the concentra-dating uses the relation of age and the marine strontium-87 to tion of these same ions in seawater (fig. 28). Silica concentra- strontium-86 (87Sr/86Sr) ratio (Howarth and McArthur, 1997; tions in surface-water samples ranged from a low of 3.32 mg/L McArthur and others, 2012). Unlike 3H/3He and SF6 age dating, in the Card Sound Road Canal 7.7 mi Upstream from Mouth which provide estimates of the age of the water, 87Sr/86Sr to a high of 8.81 mg/L at C9 Canal near NE 17 Ave. Silica ages reflect the ages of the rock with which this water has was most enriched in groundwater samples from well G-3701 equilibrated. Most of the carbonate rocks in south Florida are (fig. 28), which is most likely open to the Pinecrest Sand marine in origin and the 87Sr/86Sr ratios in the minerals of the Member of the Tamiami Formation rather than to the Biscayne rock correspond to those of seawater during deposition. The aquifer. The Pinecrest Sand Member typically is characterized 87 Sr/86Sr ratios of groundwater samples, in turn, reflect those of as a fine quartz sand that has low (0.1 to 10 feet per day [ft/d]) the strata with which this water has equilibrated. This under-hydraulic conductivity (Reese and Cunningham, 2000). The standing can aid in determining whether the sampled water quartz in these sediments may have enriched the sampled emanates from the same strata from which it was sampled, or water in silica relative to the water that flowed through the from deeper or shallower strata. Although water with different carbonate Biscayne aquifer. Wells G-3600, G-3601, G-3602, 87 Sr/86Sr ages are mixed within an aquifer, water samples that and G-3603, which also were enriched in silica, are the four indicate older or younger 87Sr/86Sr ages than the ages of the deepest wells sampled. The lithologic descriptions from aquifer materials may indicate upward or downward leakage of these four wells are not sufficiently detailed for stratigraphic water from other aquifers (Schmerge, 2001).
Characterization and Distribution of Saltwater in the Biscayne Aquifer 35 20 EXPLANATION 18 Theoretical freshwater/seawater G-3701 mixing line Card Sound Road Canal 7.7 mi upstream 16 from mouth/ seawater mixing line C9 Canal near NE 17 Ave/seawater mixing line 14 Groundwater sample Silica, in milligrams per liter Surface-water sample 12 G-3602 Seawater G-3603 10 G-3601 C9 Canal near NE 17 Ave G-3609, G-3698, G-3702, G-3705 G-3604 8
G-3600 G-901 F-279 G-3605 G-939 6
G-3704 G-3615 G-1264 4 G-3855, G-3946D G-3856 G-3699 FKS4 FKS8 2 Card Sound Road Canal 7.7 mi upstream from mouth 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 28. Silica and chloride concentrations in samples.
The 87Sr/86Sr ratios of the 14 samples collected from The 87Sr/86Sr ages of water samples from wells groundwater wells during the current study range from G-3601 and G-3701 (1.87 and 1.66 Ma, respectively) do not 0.70909 to 0.70917 (+/- 0.00002) (table 4), which correspond coincide with the age of the Tamiami Formation; however, to interpolated mean 87Sr/86Sr ages of 1.87 to 0.19 million they are older than the ages of any other groundwater samples years (Ma) before present, respectively (table 4, McArthur and (table 4). These wells likely only penetrate a few meters others, 2012). Given the precision of 87Sr/86Sr ratio analyses, into the Pinecrest Sand Member. There may be mixing of the potential range in mean age is 2.51 to 0 Ma. This age range water between the geologic formation, therefore, which corresponds to the Pleistocene and Holocene Epochs (Walker could explain the 87Sr/86Sr ages of the water samples from and others, 2012) during which the strata of the Biscayne G-3601 and G-3701.
aquifer, including the Fort Thompson Formation, Key Largo Formation, Lake Flirt Marl, Miami Limestone, and Pamlico Sand, were deposited (fig. 6). The 87Sr/86Sr ages, therefore do Oxygen and Hydrogen Stable Isotopes not indicate any flow of deeper, older water into the Biscayne aquifer at these well locations. The concentrations of stable isotopes of hydrogen Although the 87Sr/86Sr ages of all samples correspond and oxygen in water are affected by fractionation during to the Holocene and Plestocene Epochs, wells G-3601 and evaporation and precipitation. Evaluations of the likely G-3701 are likely open to the upper most part of the Pinecrest sources from which water has originated can be aided by Sand Member of the Tamiami Formation deposited during the determination of the amount of fractionation that has occurred Pliocene Epoch. The Pinecrest Sand Member is considered to in water samples. The oxygen and hydrogen stable isotope be part of the Biscayne aquifer at the location of well G-3601. composition of precipitation follows a well-defined linear Well G-3601 is 57.9 m deep and the depth of the top of the trend known as the global meteoric water line (GMWL)
Pinecrest Sand Member is estimated to be about 55 m in this (Craig, 1961). Local evaporation causes systematic enrich-area (Fish and Stewart, 1991). The Pinecrest Sand Member ment of the heavier oxygen and hydrogen stable isotopes that underlies the Biscayne aquifer at the location of well G-3701. results in divergence of the stable isotopic composition of Well G-3701 is 25.3 m deep, and the depth of the base of the local surface water from the GMWL. The line showing this Biscayne aquifer at this location is estimated to be 20.5 m (see divergence is called the local evaporation line (LEL). The the Relict Seawater from Previous Sea-Level High Stands isotopic ratios of hydrogen (2H/1H) and oxygen (18O/16O) are section of this report). typically expressed as delta deuterium (2H) and delta oxygen
36 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 4. Determination of the strontium-87 to strontium-86 ratio in water samples collected during 2009, in Miami-Dade County, Florida.
[g/L, micrograms per liter; -, no data]
Interpolated mean Strontium-87 Strontium-87 Strontium strontium-87 to USGS station Local identifier Date to strontium-86 to strontium-86 concentration, strontium-86 age number ratio ratio rerun* in g/L in millions of years C1 CANAL AT G -3702 253334080213600 8/6/2009 0.70910 0.70910 824 1.66 C2 CANAL 150 FT 254012080170200 8/3/2009 0.70911 - 603 1.47 UPSTREAM OF S-22 C2 CANAL AT G-3608 254108080170600 7/28/2009 0.70909 - 607 1.87 C8 CANAL AT G-3601 255358080114100 8/17/2009 0.70914 - 588 0.95 F-279 255315080111501 8/2/2009 0.70914 - 3,110 0.95 FLORIDA CITY 252652080244300 8/20/2009 0.70919 - 807 0.00 CANAL AT G-3699 G-894 255350080105801 8/14/2009 0.70914 - 599 0.95 G-896 254107080165201 8/4/2009 0.70912 - 801 1.29 G-939 253652080183701 8/27/2009 0.70911 - 2,940 1.47 G-3601 255358080114101 8/17/2009 0.70909 - 1,710 1.87 G-3607 254156080172101 7/17/2009 0.70916 - 978 0.47 G-3608 254108080170601 7/27/2009 0.70911 - 814 1.47 G-3609 254005080171601 7/30/2009 0.70913 - 2,450 1.12 G-3611 253710080184701 8/12/2009 0.70917 0.70917 1,130 0.19 G-3699 252652080244301 8/20/2009 0.70916 0.70915 7,320 0.47 G-3701 253214080224601 8/7/2009 0.70910 - 4,040 1.66 G-3702 253334080213601 8/6/2009 0.70916 0.70916 2,410 0.47 G-3855 252650080252701 8/18/2009 0.70913 - 5,880 1.12 G-3856 252650080252401 8/18/2009 0.70914 0.70915 1,500 0.95
- Selected samples were rerun as a quality assurance check.
18 (18O) in parts per thousand (per mil). Differences in the exception of results from wells G-901, G-3601, and G-3856, 2H and 18O composition in water samples can be evaluated which were outliers (fig. 29A). The resulting equation is graphically to differentiate between water of various sources (Richter and Kreitler, 1993, p. 28). Following the techniques 2H = (0.0013)x-10.97, r2 = 0.90, n=32, (3) similar to those applied by Schmerge (2001) in southwestern Florida, a linear regression of the results of 46 groundwater where x is the chloride concentration in milligrams per liter.
and surface-water samples with chloride concentrations Using the same set of sample results, an LSWML expressing less than 300 mg/L was used to infer an LEL that follows 2H as a function of 18O is the relation:
2H = (5.89) 18O+2.69, r2 = 0.97, n=32, (4)
H = (5.43) O+1.35, r = 0.98, 2 18 2 (2)
The 2H and 18O in samples, as well as the GMWL, The equation for this line is similar to other LEL, and LSWML, are presented in figure 29B. The 2H determinations of evaporation lines in Florida (Kendall and and chloride concentrations in samples and the LSWML are Coplen, 2001; Schmerge, 2001; Florea and others, 2010). presented in figure 29A. The intersection of the LEL and the A local saltwater mixing line (LSWML) was estimated GMWL provides an estimate of the weighted mean isotopic by performing a linear regression on groundwater samples that composition of annual precipitation in the catchment (Gibson had a chloride concentration greater than 300 mg/L, with the and others, 1993, p. 81). For this study area, the LEL intersects
Characterization and Distribution of Saltwater in the Biscayne Aquifer 37 A
10 FKS 7, G-896, G-3603, G-3606, G-3600 5 G-3607, G-3608, G-3610, G-3 G-3611, G-3700, G-3885 699 G-3 699 y = 0.0013x - 10.97 G-9 01 R² = 0.90 FK S4 0
604 S8 Delta deuterium, per mil G-3 G-3 S4 FK 601 FK S8 EXPLANATION FK G-3 Local saltwater mixing G-3 704 line (LSWML)
-5 856 G-3 615 Surface-water sample G-3 G-1 615 264 Groundwater sample G-9 Replicate groundwater sample
-10 G-9 39 39 Samples used to create LSWML G-3 605 F-279, G-3602, G-3 G-3855, G-3946D 701
-15 F-45 G-3609, G-3698, G-894 G-3702, G3705
-20 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 Chloride concentration, in milligrams per liter B
10 G-3600 C9 Canal near NE 17 Ave EXPLANATION 5 C5 Canal at NW 32 Ct, C1 Canal at G-3702, Global meteoric mixing G-3699 G-3601, G-3604 C2 Canal 150 ft line (GMML) (Craig, 1961)
FKS 8 upstream of S-22, Local saltwater mixing Card Sound Road Canal 7.7 mi upstream C2 Canal at G-3608 line (LSML) 0 from mouth, F-279, G-1264, G-3602, VSMOW Local evaporation line Delta deuterium, per mil G-3607, G-3855, G-3856, G-901 (LEL) and G-3946D Canal at G-3698, Canal, G-3608 Vienna standard mean ocean C100A at SW 72 Ave, water (VSMOW)
-5 Florida City Canal FKS4, G-896, Surface-water sample at G-3699 and G-3704 Groundwater sample G-3606, G-3610, Replicates groundwater sample
-10 G-3700, G-3701 C8 Canal at G-3601, FKS-7, G-939, G-3603, G-3605, C2 canal replicates G-3609, G-3611, G-3615, G-3698, G-3702, G-3705, G-3608 and G-3885 F-45 C-2 canal
-15 G-3608 replicates Weighted mean isotopic composition of annual precipitation in the catchment G-894, August 2009, September 2010
-20
-4 -3 -2 -1 0 1 2 Delta oxygen-18, per mil Figure 29. Relations between (A) chloride concentration and delta deuterium and (B) delta oxygen-18 and delta deuterium in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
38 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater the GMWL at respective 2H and 18O values of -16.9 and wells also have chloride concentrations ranging between
-3.37, which is almost exactly where the sample results of well 7,600 and 9,820 mg/L. The relative enrichment in heavier G-894 plot (see the Biscayne Canal section of this report). isotopes of the samples from these wells therefore is likely a The LSWML and LEL are similar, and it is difficult to result of mixing with encroaching seawater (see the Saltwater distinguish between water that has undergone evaporation in Encroachment section of this report).
canals or the Water Conservation Areas (WCAs) and water that has mixed with seawater. The slope of the LSWML is slightly closer to the slope of the GMWL than to the slope of Tritium and Uranium Concentration the LEL. All of the samples used to determine the LSWML Tritium concentration in samples in the study area came from groundwater wells, but a large proportion of the averaged 1.3 TU, and had a standard deviation of 0.8 TU, samples used to create the LEL were from canals that begin with the exception of the samples from Card Sound Road at, or within, the WCAs and (or) Lake Okeechobee (fig. 1).
Canal 7.7 mi Upstream from Mouth, wells G-1264, G-3698, This surface water may have undergone evaporation while G-3699, G-3855, and G-3856, and in one of the two samples it resided in the canals, WCAs, or the other surface-water from well FKS4, which had tritium concentrations ranging features. Once the water enters an aquifer, evaporation is from 4.1 to 53.3 TU and averaging 12.4 TU. These sites are all curtailed or ceases; therefore, the groundwater may have located within 8.5 km of the Turkey Point Nuclear Power Plant undergone less evaporation than the water sampled from Cooling Canal System (CCS) (see the Turkey Point Nuclear the canals. Even so, the equations of the LEL and LSWML Power Plant Cooling Canal System section of this report).
determined herein are similar. This similarity may be because Dissolved uranium ranged from 0.852 to 8.83 micrograms of the considerable amount of interaction between the surface-water and groundwater systems in the study area. per liter (µg/L) in samples from the surface-water sites C1 Canal The 2H and 18O composition of some canal samples may at G-3702, Canal at G-3698, and Florida City Canal at G-3699 reflect greater proportions of base flow from groundwater, and in samples from wells G-3615, G-3698, G-3699, G-3700, whereas some well samples may reflect greater proportions G-3701, G-3702, G-3855, and G-3856 (appendix 2, table 2-1),
of recharge to the aquifer from canals. The sample from Card which are located in a 6.1-km2 area in southeastern Miami-Sound Road Canal 7.7 mi Upstream from Mouth (fig. 29B) Dade County near the CCS. The greatest dissolved uranium indicates an isotopic composition that is more similar to that concentrations were 8.83 and 6.25 µg/L in wells G-3699 and of many of the groundwater samples (shifted to the left of G-3701, respectively (appendix 2, table 2-1). All samples from the LEL) than to the isotopic compositions of most other surface-water sites or wells located outside of the 6.1-km2 area canal samples. The Card Sound Road Canal begins as a small had dissolved uranium concentrations less than 0.656 µg/L; the ditch not far upstream from where the sample was collected, average concentration was 0.181 µg/L +/- 0.216 µg/L. Samples and most of the flow in the canal is sustained by base flow from many of the sites in the 6.1-km2 area also indicate tritium from groundwater. concentrations ranging from 4.1 to 53.3 TU. The site Card The range of 2H in groundwater samples was -16.9 to Sound Road Canal 7.7 mi Upstream from Mouth and wells 6.50 per mil, and 2H in surface-water samples ranged from FKS4 and G-1264 had elevated tritium concentrations, but were
-9.41 to 3.89 per mil. The range of 18O in groundwater not sampled for uranium.
samples was -3.38 to 0.57 per mil. In surface-water samples, this range was -2.00 to 0.36 per mil. The samples from well G-3600 indicated greater 2H and 18O values than any of Tritium/Helium-3 Age Dating the other samples (fig. 29B). This finding may stem from a 3 H/3He age dating can be used to date water younger combination of a greater extent of evaporation, and a greater than about 40 years. Generally tritium and helium are non-proportion of seawater in the samples from this well than in other samples. Water samples from C2 Canal at G-3608 and reactive and are unaffected by groundwater chemistry or by C2 Canal 150 ft Upstream of S-22 on the Snapper Creek anthropogenic contamination. 3H/3He age dating uses the Canal and C9 Canal near NE 17 Ave on the Snake Creek known half-life of tritium and the 3H/3He ratio measured in Canal appear to have undergone more evaporation relative to water samples to estimate an age of the water. Although some the other canal samples (fig. 29B). Wells G-3608 and G-901, mixing of younger and older water may occur as water flows which are near the Snapper Creek Canal, also have sample through the ground, the simplest and most common transport results that plot close to those from the Snapper Creek Canal assumption in ground-water age dating is to assume piston (fig. 29B). This finding may indicate that surface water within flow, which assumes that the constituent concentration was the Snapper Creek Canal has contributed a large proportion of not altered by transport processes (such as mixing or disper-the water sampled in these wells (see the Snapper Creek Canal sion) from the point of entry to the measurement point in the section of this report). aquifer (Rupert and Plummer, 2004, p. 9). Within the study The water samples collected from wells FKS8 and area, however, intruding saltwater has almost certainly mixed G-3699 had greater 2H and 18O values than did the samples with freshwater in the aquifer and/or canals. Saltwater from from the canals adjacent to these wells, which are the Card recent intrusion events may have mixed with saltwater from Sound Road and the Florida City Canals, respectively. These previous intrusion events. Therefore, although the piston-flow
Characterization and Distribution of Saltwater in the Biscayne Aquifer 39 ages are provided, the age likely represents a mixture of water Estimates of Recharge Temperature Based on of various ages.
Dissolved Gases After corrections were applied (appendix 10), the analytical ages of water in the study area ranged from Recharge temperature is the temperature of groundwater 6 +/- 0.5 to 46 +/- 2.3 years (table 5). Actual ages of water are after it is isolated from the soil atmosphere (Plummer and likely less precise than the analytical ages provided (table 5) others, 2003). Recharge temperatures are determined using because of uncertainties in the 3He/4He ratio, recharge the assumptions that the gases dissolved in the groundwater temperature, and the amount gas fractionation. Therefore, originate from air-water solubility as described by Henrys interpreted piston-flow ages are provided (table 5) that Law and that excess air is introduced into the aquifer during consider these factors. Many of the wells sampled have water recharge from air-bubble entrainment as a result of a rise in younger than 1970, which could be caused by saltwater the water table (Hinkle and others, 2010, Aeschbach-Hertig intrusion events occurring after 1970 or mixing of younger and others, 1999, 2000). Dissolved nitrogen (N2) and argon freshwater with older saltwater. The interpreted piston-flow (Ar) concentrations are used to evaluate recharge temperatures ages of water samples that had a chloride concentration of (Aeschbach-Hertig and others, 1999; 2000; Busenberg and about 1,000 mg/L or greater were generally older than those others, 1993; Heaton, 1981; and Heaton and Vogel, 1981). The samples with a chloride concentration of less than about accuracy of this method is typically +/- 0.5 oC using laboratory 1,000 mg/L. The ages of water samples that had a chloride standards (Plummer and others, 2003). Uncertainty in the concentration of about 1,000 mg/L or greater correspond to nitrogen/argon (N2/Ar) recharge temperatures can result from a period during which droughts were more frequent and of uncertainties in recharge elevation, presence of excess N2 longer duration (fig. 30). The relation between the ages of from denitrification of NO3- (degassing), and the presence saltwater samples and drought periods (fig. 30) concurs with of excess air in samples. In Miami-Dade County near the historical observations that the greatest extents of saltwater coast, where samples were collected, the water table gener-intrusion generally occurred during droughts, when fresh ally varies seasonally and geographically by only a few feet groundwater heads are low and saltwater may encroach along (Lietz and others, 2002), so uncertainty in recharge elevation the base of the aquifer or flow inland in canals, rivers, or tidal is negligible. Denitrification can affect the determination of marshes (see Relation of Urban Development to Saltwater recharge temperatures and excess air in samples. The amount Intrusion section of this report). of excess N2 from denitrification was estimated from the solubility of Ar using an iterative procedure.
Sulfur Hexafluoride Age Dating The dissolved gas concentrations of argon, carbon dioxide, methane, nitrogen, and oxygen, were determined for 23 samples Sulfur hexafluoride (SF6) can be used to date groundwater from selected sites (appendix 2, table 2-2; U.S. Geological that is younger than 30 years (Busenberg and Plummer, 2000). Survey, 2011i) to determine the recharge temperatures of SF6 concentrations in 40 samples ranged from 0.33 to 136 parts individual samples. Sample results indicate a relation between, per thousand total volume (pptv) (appendix 2, table 2-4). Ages N2/Ar recharge temperature, seasonal changes in air temperature could not be determined for most of these samples, however, and water level, and the salinity of samples (figs. 31A and 31B, because the samples contained greater amounts of SF6 than table 7). The recharge temperatures of most of the samples would result from equilibrium with the expected atmospheric with chloride concentrations greater than or equal to about concentration. Samples containing the highest concentrations 1,000 mg/L (samples from the seaward side of the saltwater of SF6 generally were from surface-water monitoring sites or interface) indicated a range in the N2/Ar recharge temperature monitoring wells near electrical power distribution facilities. of 23.8 - 25.4 °C, which is similar to the air temperatures that These sites include C2 Canal 150 FT Upstream of S-22, occur when aquifer water levels are at minimum levels, and Florida City Canal at G-3699, C2 Canal at G-3608, and the potential for saltwater intrusion is greatest (The Weather Canal at G-3698 and wells F-45 and G-3700 (appendix 2, Channel, 2013; figs. 31A and 31B, table 7).
table 2-4). Leakage of SF6 from electrical power generation The recharge temperatures of samples with chloride facilities in southeast Florida has been noted previously concentrations less than about 1,000 mg/L (the freshwater side (U.S. Environmental Protection Agency, 2000) and may account of the saltwater interface) generally indicated warmer recharge for the excess SF6 found in at least some of the samples. temperatures and, with one exception, had recharge tempera-Even where SF6 concentrations were low enough to allow tures between 25.5 - 26.8 °C. This range of temperatures corre-an estimation of age, the SF6 ages typically disagreed with sponds to average air temperatures in the second half of May the 3H/3He ages (table 6). Only the near absence of SF6 in when rainfall and water levels in the aquifer typically begin to some samples indicates that water at these locations may be increase (figs. 31A and 31B). The samples from wells G-3609 older than elsewhere. Samples from wells G-3600, G-3601, and G-3855 were exceptions to these general relations.
G-3603, G-3609, and G-3701 had the least amounts of SF6 Water samples that have N2/Ar recharge temperatures (0.33 to 1.21 pptv; appendix 2, table 2-4). Samples from wells indicative of the end of the dry season when aquifer water G-3600, G-3601, and G-3701 also had too little tritium for levels are low, also have interpreted 3H/3He piston-flow ages 3
H/3He age dating. that correspond to a period of frequent droughts (see the
Table 5. Results of tritium/helium-3 age dating of water samples collected during 2009-2010 in Miami-Dade County, Florida.
[?, could not be determined; , standard deviation; TU, tritium unit; %, percent; <, less than; ~, about; -, no data]
4He/ Analytical age, Analytical age, cor- Interpreted Terrigenic Tritium 4He Ne Ne 2 uncorrected for ter- rected for piston-flow Comments USGS station Sample He Local identifier Ratio1 rignic helium3 terrignic helium age4 number date TU +/-1 % years +/-1 years +/-1 year (TU) (years) (years)
C2 CANAL AT 254108080170600 7/28/2009 2.08 0.13 2.6 4.8 0.5 -2.95 1 0.1 - - - Result not used because of gas fractionation G-3608 and direct exposure to air.
F-279 255315080111501 8/21/2009 0.67 0.12 31.5 7.5 4.2 17.39 - - 45 3.0 < 1970 Result corrected for terrigenic helium.
G-3600 255626080093201 8/12/2010 0.25 0.04 13.6 -7.7 -1.8 19.87 - - - - - Negative Ne indicates gas fractionation, age is questionable.
G-3601 255358080114101 8/17/2009 -0.05 0.1 32.3 9.7 3.3 15.89 - - - - - Too little tritium to age date.
G-3607 254156080172101 7/17/2009 1.68 0.09 19.5 17.4 1.1 -0.64 16 0.6 - - ~ 1993 Result without terrigenic helium correction.
G-3608 254108080170601 7/27/2009 1.66 0.1 5.8 8.6 0.7 -3.95 12 0.5 - - ~ 1997 Result without terrigenic helium correction.
Possible gas fractionation.
G-3609 254005080171601 7/30/2009 0.74 0.08 43.6 19.1 2.3 14.97 - - 34 1.8 1970s Result corrected for terrigenic helium, age uncertain because of very low tritium.
G-3611 253710080184701 8/12/2009 1.55 0.11 26.1 24.3 1.1 -1.68 29 1.1 - - late 1970s Result without terrigenic helium correction, early 1980s age uncertain because of very low tritium.
G-3698 252814080244101 7/20/2010 5.73 0.11 34.6 9.2 3.8 17.73 - - 24 0.3 ~ 1986 Result corrected for terrigenic helium.
G-3699 252652080244301 8/20/2009 45.8 0.91 24.3 4.6 5.3 15.3 - - 28 0.3 ~ 1981 Result corrected for terrigenic helium.
G-3701 253214080224601 8/7/2009 0 0.11 33.1 18 1.8 9.17 - - - - - Too little tritium to age date.
G-3702 253334080213601 8/6/2009 0.74 0.1 31.7 20.4 1.6 6.02 - - 46 2.3 < 1970 Result corrected for terrigenic helium.
G-3704 254822080125501 7/21/2010 0.54 0.04 71.7 11.4 6.3 33.85 - - 29 1.2 late 1970s Result corrected for terrigenic helium age early 1980s uncertain because of low very low tritium.
G-3705 255625080094901 8/12/2010 1.49 0.05 15.4 4.2 3.7 9.13 - - 30 0.5 ~ 1980 Result corrected for terrigenic helium.
G-3855 252650080252701 8/18/2009 17.8 0.36 20.3 8.1 2.5 9.01 - - 26 0.3 ~ 1983 Result corrected for terrigenic helium.
(Trigger)
G-3856 252650080252401 8/18/2009 4.59 0.13 5.4 4.9 1.1 -0.26 17 0.3 - - ~ 1992 Result without terrigenic helium correction.
(Sentinel)
G-894 255350080105801 8/14/2009 1.43 0.15 10 13 0.8 -4.62 6 0.5 - - ~ 2003 Result without terrigenic helium correction.
Possible gas fractionation.
G-896 254107080165201 8/4/2009 1.68 0.06 9.8 13.4 0.7 -5.24 11 0.3 - - ~1998 Result without terrigenic helium correction.
Possible gas fractionation.
G-939 253652080183701 8/27/2009 1.08 0.12 18.6 10.5 1.8 5.47 - - 26 1.7 ~1983 Result corrected for terrigenic helium.z 1
Samples indicating a 4He/Ne ratio of less than 1 may have been affected by gas fractionation.
2 40 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Corrections for terrigenic helium were applied to samples that indicated that terrigenic helium was greater than 5 percent.
3 Analytical age is based on precision of analysis but this precision does not consider other factors such as uncertainties in the recharge temperature, 3He/4He ratio, and gas fractionation.
4 Interpreted piston-flow age considers some uncertainties in the analysis, but does not consider the mixing which likely occurred as saltwater intruded the aquifer.
Sources of Saltwater in the Biscayne Aquifer 41 100,000 G-3699 G-939 G-3704 (~1981) (~1983)
F-279 (late 1970s, G-3855 10,000 Chloride concentration,
(< 1970) early 1980s) (~1983)
G-3609 G-3698 1,000 G-896 (1970s) G-3705 (~1986)
G-3702 (~1980) (~1998)
G-3856
(<1970) in milligrams per liter
(~1992) 100 G-3611 G-3608 G-894 (late 1970s, (~1997) (~2003) early 1980s) G-3607 10 1938 1943 1949 1960 1970 1980 1984 (~1993) 2000 to to to to to to to 1939 1946 1957 1963 1977 1982 1990 1 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year EXPLANATION 1985 Drought period and year(s)
Analytical age of water sample, chloride G-3705 concentration about 1,000 mg/L and identifier.
(~1980) Interpreted piston-flow age is in parentheses Analytical age of water sample, chloride G-894 concentration < about 1,000 mg/L and identifier.
(~2003) Interpreted piston-flow age is in parentheses.
Dashed where gas fractionation may have affected sample
~ Approximately Figure 30. 3H/3He interpreted piston-flow ages of water samples collected during 2009-2010 in the Miami-Dade County area and dates of documented droughts in south Florida. [mg/L, milligrams per liter]
Tritium/Helium-3 Age Dating section of this report), whereas Relict Seawater from Previous Sea-Level High those that have warmer recharge temperatures generally Stands have younger ages that correspond to a period during which droughts were infrequent (fig. 30). Previous research has Results of this study indicate that saltwater sampled in shown that saltwater usually intrudes when water levels in the Biscayne aquifer in eastern and southern Miami-Dade the aquifer and in canals are at minimum levels, particularly County is not relict seawater from previous sea-level high during droughts (Cross and Love, 1942, p. 501). Minimum stands. Most of the interpreted piston-flow ages indicate that water levels are usually reached near the end of the dry season the water sampled was too young to be considered relict from April to early May, so the observed relation between seawater. Recent changes in the bulk conductivity of EMI recharge temperatures, water levels in the aquifer, and salinity logs and the chloride concentrations in samples collected from of samples is not surprising. This relation assumes piston these wells indicate that the water in these wells is probably flow, however, which may not be the best assumption since not relict seawater. The chloride concentrations in water saltwater and freshwater likely mixed in the aquifer. sampled from these wells has varied by between 325 mg/L and 2,732 mg/L during the few decades that the wells have been monitored. Changes in salinity occurring during such short Sources of Saltwater in the Biscayne periods of time indicate that the transmissivity of the aquifer at these locations is likely sufficient to have allowed freshwater Aquifer to replace any relict saltwater during the last Pleistocene low stand.
The Biscayne aquifer has several potential sources of The changes in chloride and bulk resistivity at monitoring saltwater or pathways through which saltwater can intrude. It wells G-3601 and G-3701, open to the Pinecrest Sand is important to differentiate between these sources or pathways Member of the Tamiami Formation, are likely too large to be because if they are misconstrued, the corrective measures due to relict seawater, even though the transmissivity of this implemented to prevent saltwater intrusion in affected areas geologic unit is very low relative to transmissivities of most could fail to address the actual causes. Geochemistry, TSEMIL of the geologic units in the Biscayne aquifer. The chloride datasets, TEM soundings, long-term chloride concentration concentration in well G-3601 (fig. 32B) increased from 660 to data, and the 2001 HEM survey were used to identify the 1,400 mg/L during 1999 to 2011. The bulk conductivity probable sources and ages of saltwater in the aquifer at various of EMI logs from well G-3601 (figs. 32A and 32B) gradu-locations within the study area. ally increased from about 42 to 87 mS/m during 1996 to
42 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 6. Differences between ages determined using SF6 and tritium/helium-3 age dating for samples collected in Miami-Dade County, Florida, during 2009-2010.
[/, denotes ratio; C, contaminated with excess SF6; --, no data]
Difference Analytical between Average piston- tritium/ analytical Local USGS station Sample flow model SF6 helium-3 tritium/
Comments identifier number date recharge age, piston flow helium-3 in years 1 age, in age and years2 SF6 age, in years C2 CANAL 254108080170600 7/28/2009 C 1 -- Tritium/helium-3 age not used because of AT G-3608 gas fractionation and exposure to air F-279 255315080111501 8/21/2009 23.6 45 21 --
G-3600 255626080093201 8/12/2010 27.6 -- -- Tritium/helium age likely affected by gas fractionation G-3601 255358080114101 8/17/2009 36.4 -- -- Tritium content too low for tritium/
helium-3 age dating G-3607 254156080172101 7/17/2009 C 16 -- --
G-3608 254108080170601 7/27/2009 C 12 -- --
G-3609 254005080171601 7/30/2009 29.8 34 4 --
G-3611 253710080184701 8/12/2009 14.9 29 15 --
G-3698 252814080244101 7/20/2010 C 24 -- --
G-3699 252652080244301 8/20/2009 C 28 -- --
G-3701 253214080224601 8/7/2009 32.6 -- -- Tritium content too low for tritium/
helium-3 age dating G-3702 253334080213601 8/6/2009 4.10 46 42 --
G-3704 254822080125501 7/12/2010 24.3 29 5 --
G-3705 255625080094901 8/12/2010 23.1 30 7 --
G-3855 252650080252701 8/18/2009 2.90 26 23 --
G-3856 252650080252401 8/18/2009 C 17 -- --
G-894 255350080105801 8/14/2009 5.90 6 0 --
G-896 254107080165201 8/4/2009 C 11 -- --
G-939 253652080183701 8/27/2009 17.9 26 8 --
1 Because so many of the samples were contaminated with excess amounts of SF6, and because the ages determined even for those samples with dateable amounts of SF6 were younger in every instance than the ages determined using tritium-helium-3 age dating, the SF6 ages are not reliable and should not be used.
2 Analytical age is based on precision of analysis but this precision does not consider other factors such as uncertainties in the recharge temperature, 3He/4He ratio, and gas fractionation.
2011. If changes of this magnitude occurred in a little more The SF6 concentrations in samples from wells G-3601, than one decade, then the freshwater flow during the last G-3602, G-3604, G-3605, and G-3701 (0.33 to 5.92 pptv) sea-level low stand should have been sufficient to remove (appendix 2, table 2-4) indicate that the interpreted piston-any relict saltwater in this part of the aquifer. EMI logs from flow age of water in these wells is more recent than 1952, but well G-3701 show changes in bulk conductivity within the potential contamination by excess SF6 (table 6) renders the Biscayne aquifer, and below it, in the Pinecrest Sand Member result inconclusive.
(fig. 33A and 33B). The open interval of this well begins 3.3 m below the base of the Biscayne aquifer. Changes in bulk resistivity in the Biscayne aquifer at well G-3701 are much Historical Leakage of Saltwater from Canals greater than those in the Pinecrest Sand Member. Nonetheless, during 2002 to 2011, the chloride concentration of water Some of the existing saltwater in the Biscayne aquifer samples from well G-3701 (fig. 33B) varied from 355 to near primary drainage canals such as the Biscayne, Miami, 680 mg/L, which is likely sufficient variation to indicate that Tamiami, and Card Sound Road Canals may have been freshwater replaced any relict saltwater within the Pinecrest caused by the flow of saltwater inland prior to the installation Sand Member. of salinity control structures. Between May and July 1945,
Sources of Saltwater in the Biscayne Aquifer 43 Table 7. Average recharge temperature and chloride concentration of surface-water and groundwater samples collected in Miami-Dade County, Florida during 2009-2010.
[°C, degrees Celsius; mg/L, milligrams per liter]
Average recharge tem- Chloride water, Local identifier USGS station number Sample date perature (°C) filtered * (mg/L)
C2 CANAL 150 FT 254012080170200 12/15/2009 26.6 44.7 UPSTREAM OF S-22 C2 CANAL AT G-3608 254108080170600 12/14/2009 26.8 42.5 C2 CANAL AT G-3608 254108080170600 7/28/2009 29.6 41.2 F-279 255315080111501 8/21/2009 25.3 3,480 G-3601 255358080114101 8/17/2009 24.7 1,270 G-3607 254156080172101 7/17/2009 25.9 58.2 G-3608 254108080170601 12/15/2009 26.5 158 G-3608 254108080170601 7/27/2009 26.5 173 G-3609 254005080171601 12/17/2009 25.4 1,220 G-3609 254005080171601 7/30/2009 26.4 1,180 G-3611 253710080184701 8/12/2009 26.6 175 G-3615 253024080231001 12/16/2009 24.6 3,600 G-3698 252814080244101 7/20/2010 24.7 1,200 G-3699 252652080244301 8/20/2009 24.5 8,910 G-3700 253027080234701 12/16/2009 25.7 23.2 G-3701 253214080224601 8/7/2009 25.9 832 G-3702 253334080213601 8/6/2009 25.1 997 G-3704 254822080125501 7/21/2010 24.8 6,190 G-3855 252650080252701 8/18/2009 26.8 3,760 G-3856 252650080252401 8/18/2009 25.7 553 G-894 255350080105801 8/14/2009 25.8 18.0 G-896 254107080165201 8/4/2009 25.5 211 G-939 253652080183701 8/27/2009 23.8 3,410 Samples with a chloride concentration of about 1,000 mg/L or greater are highlighted in pink.
saltwater with chloride concentrations ranging from 1,100 to others (2012) identified saltwater at the base of the Biscayne 26,000 ppm was sampled at distances ranging from 4.7 to aquifer, extending about 15 km inland, beneath the Card 20 km inland in most of the primary canals in Miami-Dade Sound Road Canal. This saltwater extends farther inland in the County (Parker and others, 1955, p. 633 and 680). Samples area between U.S. Highway 1 and the Card Sound Road Canal from wells and geophysical measurements made near than it does to the west. Fitterman and others (2012) concluded these canals in the present study indicate elevated chloride that this saltwater likely leaked from the Card Sound Road concentrations and bulk conductivities and lower than normal Canal and FEC borrow ditches. During the drought of resistivity in these areas. 1943-46 (fig. 4), saltwater with a chloride concentration of 26,000 ppm was sampled in the Card Sound Road Canal as far inland as 20.0 km (Parker and others, 1955, p. 680, fig. 188).
The Card Sound Road Canal and FEC Railway In June or July 1945, the FEC railway borrow ditches were Borrow Ditches strongly contaminated [with saltwater] to a distance less than 6 mi from Florida City, and it was considered possible that Historical saltwater intrusion near the Card Sound Road ground-water contamination continued even farther inland Canal and Florida East Coast (FEC) railway borrow ditches (Parker and others, 1955, p. 682). A 1955 map shows saltwater likely contributed to the saltwater detected by the 2001 in the Biscayne aquifer extending about 18-19 km inland HEM survey (Fitterman and others, 2012). Fitterman and beneath the Card Sound Road Canal and the FEC railway
44 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater B
1.2 Average daily maximum water level, in meters 1.1 1.0 0.9 0.8 0.7 0.6 Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Month A
30 25 29 DRY SEASON WET SEASON 28 Range in recharge temperatures of most water 27 samples with < ~1,000 mg/L chloride 20 Average monthly precipitation, centimeters 26 Temperature, degrees Celsius 25 Range in recharge temperatures of most water samples with > ~1,000 mg/L chloride 24 15 23 22 21 10 20 19 18 5 17 16 15 0 Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Month EXPLANATION Average monthly precipitation Range in recharge temperatures of most samples with chloride concentrations greater than or equal to about 1,000 mg/L Range in recharge temperatures of most samples with chloride concentrations less than about 1,000 mg/L Polynomial regression of daily average daily air temperature Delineates the period of minimum average maximum daily water levels, and corresponding daily average air temperatures Average maximum daily water level Daily average air temperature Figure 31. (A) Average monthly precipitation, daily average air temperature in Miami, Florida, and the range of recharge temperatures of water samples collected from the Biscayne aquifer in Miami-Dade County, Florida, and (B) average of daily maximum water levels in selected wells open to the Biscayne aquifer during October 1, 1974, to September 30, 2009. [<, less than; mg/L, milligrams per liter; , greater than or equal to]
Sources of Saltwater in the Biscayne Aquifer 45 A
0 EXPLANATION G-3601 5 electromagnetic induction logs 10 1/10/1996 5/09/1996 15 4/21/1997 2004 2003 5/1998 Depth, in meters below land surface 20 4/12/1999 4/2000 4/11/2001 25 5/13/2002 4/29/2003 30 2009 2010 2011 4/22/2004 4/25/2005 35 09/13/2006 6/19/2007 40 5/05/2008 4/30/2009 45 4/21/2010 4/26/2011 50 2011 55 1996 Screened 0 10 20 30 40 50 60 70 80 90 100 56.4 to 57.9 meters Bulk conductivity, in millisiemens per meter B
1,500 95 90 1,400 85 1,300 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 80 1,200 75 1,100 70 65 1,000 60 900 55 800 50 EXPLANATION 700 Chloride concentration 45 Bulk conductivity 600 40 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 32. (A) Time-series electromagnetic induction log (TSEMIL) dataset and (B) chloride concentrations in samples from monitoring well G-3601 and bulk conductivity measured at a depth of 56.1 meters, Biscayne aquifer, Miami-Dade County, Florida.
46 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3701 electromagnetic induction logs 4/4/2001 5 Variations in bulk conductivity are common near the land surface. One possible explanation 5/15/2002 is difference in the water temperature occurring 4/24/2003 near the land surface 4/20/2004 Depth, in meters below land surface 4/14/2005 4/18/2006 10 6/13/2007 4/29/2008 In the 11-year period, bulk conductivity has 5/05/2009 varied by as much as 50 millisiemens per 4/7/2010 meter in the depth interval 12 to 12.5 meters 15 4/6/2011 20 Estimated depth of base of Biscayne aquifer Other than the first log, collected in 2000 shortly after the well was drilled, there has been little variation in bulk conductivity Screened measured below a depth of 20.5 meters. 23.8 to 25.3 meters 25 0 20 40 60 80 100 120 140 Bulk conductivity, in millisiemens per meter B
800 55 700 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 600 50 500 400 45 300 EXPLANATION Chloride concentration Bulk conductivity 200 40 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 33. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3701 and bulk conductivity measured at a depth of 24.0 meters, Biscayne aquifer, Miami-Dade County, Florida.
Sources of Saltwater in the Biscayne Aquifer 47 borrow ditches (Parker and others, 1955, p. 709, fig. 200). Turkey Point Nuclear Power Plant Cooling Canal The inland extent of the saltwater described by Fitterman and System others (2012) is about 1.5 km less than the extent mapped in the Biscayne aquifer by Parker and others (1955, p. 709, The cooling canal system (CCS) of the Turkey Point fig. 200), but is about 6 and 3 km inland of wells FKS4 and Nuclear Power Plant east of Florida City (fig. 8) was FKS8, respectively. The ion exchange front is, therefore, constructed during the early 1970s and contains hypersaline well inland of these wells. This mapped extent of saltwater water (Janzen and Krupa, 2011). This hypersaline water helps to explain why the Ca/(HCO3 + SO4) molar ratio in may be contributing to saltwater encroachment in this area water, sampled from these wells, is less than 1 and concen- (Hughes and others, 2010). Water in the cooling canals is trations of major ions typically plot near the theoretical reported to have tritium concentrations at least two orders of freshwater/seawater mixing line (figs. 19, 21, 23, 25, 26). magnitude above surrounding surface and groundwater and Results indicate that little or no ion exchange is taking place [tritium] therefore [is] considered a potential tracer of waters at these locations. from the CCS (Janzen and Krupa, 2011, section 2, p. 8).
The tritium concentration of samples collected from sites located within 8.5 km of the CCS ranged from 4.1 to 53.3 TU Miami and Tamiami Canals and averaged 12.4 TU, whereas the tritium concentration Surface water in the Miami Canal at USGS monitoring of samples collected farther away from the CCS averaged station Miami Canal at Water Plant (appendix 1) (U.S. 1.3 TU (appendix 2, table 2-3) (see the Tritium and Uranium Geological Survey, 2011f), 4 km upstream of salinity control Concentration section of this report). Saltwater intrusion is a structure S-26, had become saline (335 mg/L chloride recent occurrence at most of the groundwater monitoring wells concentration) during the drought of 1970 to 1977, and the (figs. 18, 19, 21-26) within 8.5 km of the CCS, except at wells chloride concentration of water in wells adjacent to this canal FKS4 and FKS8 near the Card Sound Road Canal (see the had increased (fig. 13). The subsequent decrease in chloride Card Sound Road Canal section of this report). No samples concentrations in wells near the Miami Canal and west of were collected from the CCS or wells within it as part of the salinity control structure S-26 (fig. 13) may be the result of current study to detect any possible influxes of CCS water into the dissipation of saltwater that had leaked from the canal. the aquifer; however, monitoring wells were installed in 2010 The area of probable historical canal leakage is indicated in adjacent to the CCS for other studies and these wells are being figure 17. A 3H/3He age-dating sample could not be obtained monitored using electromagnetic induction logging.
from well G-1351 to determine if the saltwater entered the aquifer during the 1970 to 1977 drought. The major and trace Recent Leakage from Canals ion geochemistry of samples from wells G-3604 and G-3605 near the Miami and Tamiami Canals (fig. 8) indicate little or Although salinity control structures have been installed no ion exchange. The episodes of saltwater intrusion during in most of the tidal canals, the leakage of saltwater through the droughts of 1938-1939 and 1970-1977 (figs. 4 and 13) the porous rock of the Biscayne aquifer and around existing may have filled the ion-exchange sites of the rocks and sedi- salinity control structures is documented (Parker and ments in the aquifer at these locations. The extent of saltwater others, 1955; Kohout and Leach, 1964; Leach and Grantham, intrusion in 1955 (fig. 8), 1969 (Renken and others, 2005a), 1966). Kohout and Leach (1964) reported that any saltwater and 1984 (Klein and Waller, 1985) was inland of both of these upstream of the salinity control structures could be driven wells, particularly well G-3604. into the aquifer when freshwater heads in the canals upstream of these structures increased. Monthly measurements of salinity collected by the Miami-Dade County Permitting, C-111 Canal Environmental, and Regulatory Affairs (M-D PERA) during A narrow finger of conductive groundwater extends at 1988 to 2010 (appendix 11) show influxes of saltwater in least 2.7 km inland along the C-111 Canal (fig. 8) (Fitterman many of the canals upstream of the salinity control structures.
and Deszcz-Pan, 1998, 2002). This finger is likely related These measurements at stations BL03, BS04, CD02, GL03, to the leakage of saltwater from the C-111 Canal occurring LR06, PR03, MI03, MW04, and SP04, located in the Black between 1965 when the canal was installed and 1969 when Creek, Biscayne, Cutler Drain, Goulds Canal, Little River, salinity control structure S-197 was installed. Leakage of Princeton, Military, Mowry, and Snapper Creek Canals, saltwater from the C-111 Canal peaked in 1965 when tidal respectively (fig. 8), have detected influxes of saltwater inundation from Hurricane Betsy caused saltwater with a upstream of the water control structures in these canals.
chloride concentration of 10,000 mg/L to flow as far inland The occurrences have ranged from rare influxes of water as about 3 km upstream from salinity control structure with salinity between 0.5 and 1.4 PSU at station SP04 in S-18C (Meyer, 1974, p. 28). Meyer (1974, p. 30a) also the Snapper Creek Canal, to frequent influxes of water with reported the occurrence of saltwater between 1970 and 1971 a salinity of between 15 and 32 PSU at station BS04 in the in the C-109 and C-110 Canals about 3 to 4 km north of the Biscayne Canal (appendix 11). This saltwater may be leaking C-111 Canal. into the aquifer in some areas. Moreover, many existing
48 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater monitoring-network wells are in the right-of-way of local saltwater had been detected near the northern end of the Card canals. A landward bias may exist in the assessment of the Sound Road Canal (Parker and others, 1955, p. 680) about inland extent of saltwater in the Biscayne aquifer if (1) these 5 km farther inland than in 2009. Canal levels in the area were canals are leaking saltwater, (2) there are insufficient data lower during previous droughts than in 2009. For example to define the inland extent of saltwater in areas away from during the drought of 1971, groundwater levels in this area these canals, and (3) the occurrence of saltwater at these declined to about 0.3 m below sea level (Meyer, 1974, p. 24).
locations is misconstrued as originating from movement of During the 1971 drought, water levels measured in wells the saltwater front rather than canal leakage. S-196A and G-613 near Homestead and Florida City declined to levels that were 0.5 to 0.9 m lower, respectively, than in 2009 (U.S. Geological Survey, 2011f). Other factors such as Card Sound Road Canal tide magnitudes, storm surge from hurricanes, and encroach-Prior to May 2010 the Card Sound Road Canal (fig. 1) ment along the base of the aquifer also may have contributed was one of the few canals in Miami-Dade County that lacked to the inland extent of saltwater in the Biscayne aquifer near a salinity control structure. To evaluate the potential for the Card Sound Road Canal.
landward flow of saline surface water in the Card Sound A salinity control structure was installed in the Card Road Canal, salinity profiles were collected at 11 and 12 sites, Sound Road Canal just above its junction with Canal L-31E respectively, on December 5, 2008, and May 18, 2009. The in May 2010. This structure likely will reduce the flow of salt-11 salinity profiles collected on December 5, 2008, indicated water up the Card Sound Road Canal and also may increase that salinity in the canal gradually increased from 0.27 ppt freshwater head in the Biscayne aquifer in the area. In time, at a distance of 9.5 km from the mouth of the canal, to it may reduce the landward extent of saltwater in this area, 4.24 ppt at a distance of 0.64 km from the mouth of the canal but the gradual declines in chloride concentration near the (appendix 3). As water levels in the Biscayne aquifer declined Miami Canal (fig. 13) indicate that it may take a long time for to near record low altitudes by May 16, 2009, the flow in intruded water near the Card Sound Road Canal to dissipate.
the Card Sound Road Canal reversed, and saltwater from the Florida Bay flowed inland. On May 18, 2009, water at nine Biscayne Canal sites ranging from 0.64 to 11.6 km inland from the mouth was hypersaline, and salinity ranged from 43.7 to 42.3 ppt. Salinity control structure S-28 was installed in At monitoring well FKS8, which is approximately 5 m from 1960 (table 1) about 1 km west of U.S. Highway 1 to prevent the Card Sound Road Canal and 12.4 km from its mouth, the incursions of saltwater up this canal; however, water with a average salinity of canal water was 38.6 ppt. Farther inland, salinity of 20 PSU or greater has frequently been detected at distances of 13.5 and 15.9 km from the mouth of the Card at station BS04 upstream of the salinity control structure Sound Road Canal, the salinity of canal water was 0.27 and (fig. 10). This saltwater could be leaking into the Biscayne 0.18 ppt, respectively. aquifer, but it is unknown how far upstream of this station the saltwater travels. Monitoring well G-3601 is on the eastern The influx of saltwater upstream in the Card Sound Road bank of the Biscayne Canal about 5.6 km from the mouth of Canal was identified in groundwater samples from well FKS8.
the canal and about 3.8 km upstream of structure S-28. The During February 24, 2004, to March 31, 2009, the chloride TSEMIL dataset from well G-3601 (fig. 32A) indicates little if concentrations in samples from a depth of 23 m in well FKS8 any change in bulk conductivity occurring in the depth interval ranged from 4,680 to 9,480 mg/L and averaged 8,660 mg/L, 41 to 42 m, but there are changes occurring in shallower but on May 4, 2009, and May 18, 2009, chloride concentra-and deeper intervals than this interval that do not appear tions from this depth were 14,750 and 11,575 mg/L, respec- to be related. Below this depth interval, gradual increases tively (Jolynn Reynolds, Florida Keys Aqueduct Authority, in bulk conductivity indicate that the saltwater interface is written commun., 2009). Increases in chloride concentrations gradually encroaching landward. Shallower than this depth in water samples from well FKS8 also occurred in samples interval, there have been two short-term influxes of conductive from the depths 11 and 17 m. By June 29, 2009, the chloride water: the first occurring during 2003 through 2004 in the concentrations in samples from the depth 23 m had returned depth interval 18 to 32 m, and the second occurring during to near average, but the chloride concentrations in samples 2009 through 2011 in the depth interval 30 to 39 m. One from the depth intervals of 11 and 17 m were still greater than possible source of these relatively shallow influxes could be the maximums recorded at these depths prior to the influx of leakage of saltwater from the adjacent canal.
saltwater up the Card Sound Road Canal (Jolynn Reynolds, An alternative possibility is that these influxes are Florida Keys Aqueduct Authority, written commun., 2009). associated with the saltwater front. Monitoring well G-894 On May 18, 2009, saltwater in the Card Sound Road is about 1.3 km east of well G-3601. Well G-894 is open to Canal was not as far inland as the apparent extent of saltwater the depth interval (22.7 to 23.2 m) that coincides closely with in the Biscayne aquifer determined in the 2001 HEM survey the depth of the maximum bulk conductivity measured in or mapped by Parker and others (1955, p. 709). Saltwater trav- 2003 in well G-3601. Between 1959 and 1981, the chloride eled farther inland up the Card Sound Road Canal during the concentrations in samples from well G-894 ranged from previous droughts than it did in 2009. For example, in 1945, 680 to 3,600 mg/L (fig. 18). The maximum concentration
Sources of Saltwater in the Biscayne Aquifer 49 2.0 1.8 1.6 1.4 Salinity, in practical salinity units 1.2 1.0 0.8 0.6 0.4 Figure 34. Salinity of the 0.2 Snapper Creek Canal at station SP04, 1991-2010, Miami-Dade 0
County, Florida.
1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year occurred on June 4, 1962, during the drought of the early the Snapper Creek Canal (Maria Idia Macfarlane, Miami-Dade 1960s (Waller, 1985; Bridges and others, 1991). Since 1995, County Water and Sewer Department, written commun.,
none of the samples from well G-894 have had a chloride March 7, 2011; Craig Grossenbacher, Miami-Dade County concentration greater than 50 mg/L. The current chemistry Permitting, Environmental, and Regulatory Affairs, written of samples from well G-894, appears to be dominated by commun., July 7, 2010). These influxes included (1) a salinity recharge from precipitation rather than encroaching saltwater of 1.4 PSU measured in May 1992, (2) a salinity of 0.5 PSU because the 2H and 18O of samples from this well are about measured in March 1993, and (3) a salinity of 0.6 PSU the same as the estimated weighted mean isotopic composition measured in January 2005. Although much lower than those of annual precipitation in the catchment (see the Oxygen measured in some of the other canals, these salinities are and Hydrogen Stable Isotopes section of this report). The equivalent to chloride concentrations of about 260 mg/L most likely source of saltwater contributing to shallow saline to 760 mg/L.
influxes at well G-3601, therefore, is the Biscayne Canal The TSEMIL dataset from well G-3608 indicated a rather than saltwater encroaching from the direction of well shallow increase in bulk conductivity that may have resulted G-894. This likely source could be further evaluated by from leakage of saltwater or brackish water from the adjacent monitoring salinity in the canal adjacent to the well. Snapper Creek Canal (fig. 35A). Well G-3608 is on the west bank of Snapper Creek Canal, 3.8 km upstream of its mouth and 1.7 km upstream of salinity control structure S-22. Well Snapper Creek Canal G-3608 is open to the Biscayne aquifer in the depth interval Saltwater in the Snapper Creek Canal has leaked around 29.0 to 30.5 m. The TSEMIL dataset indicated an increase salinity control structure S-22 through the highly perme- in bulk conductivity in the depth interval 16 to 26 m of the able Biscayne aquifer and has flowed inland (Sherwood log collected April 30, 2003. The bulk conductivity gradually diminished in subsequent logs until it was no longer evident and Leach, 1962). USGS water-quality monitoring during in the TSEMIL dataset. Below a depth of 26 m, the bulk 1966 to 1992 at station Snapper Creek Canal at S-22 conductivity of logs collected from G-3608 increased between Near South Miami, Fl (USGS ID 02290700), about 60 m April 2003 and April 2006 (fig. 35A). During this period, upstream of S-22, detected brackish water in September the chloride concentrations in samples increased from 72 to 1974, December 1975, January 1976, and February, March, 230 mg/L (fig. 35B). Between 2006 and 2011 the chloride and June 1977. Chloride concentrations ranged from 254 to concentrations in samples and the bulk conductivity of logs 638 mg/L, and specific conductance ranged from 1,000 to from this well decreased to levels near those occurring prior 2,500 µS/cm during the period (U.S. Geological Survey, to the influx of conductive water. This pattern could be caused 2011f). Monthly salinity monitoring during 1988 to 2010 at by the leakage of saltwater or brackish water from the Snapper station SP04, 0.5 km upstream of water control structure S-22 Creek Canal, some of which gradually sank to the base of the (figs. 8 and 34), detected only a few influxes of saltwater in aquifer where it gradually dissipated.
50 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3608 electromagnetic induction logs 5 1/9/1996 5/24/1996 4/23/1997 4/1998 Depth, in meters below land surface 10 4/9/1999 4/13/2000 4/6/2001 5/20/2002 15 4/30/2003 2003 4/23/2004 4/26/2005 4/24/2006 20 6/13/2007 5/06/2008 5/6/2009 25 2004 2005 to 2009 Screened 30 29.0 to 30.5 meters 0 10 20 30 40 50 1996 to 2003 Bulk conductivity, in millisiemens per meter excluding 2002 B
300 18 EXPLANATION 17 Chloride concentration Bulk conductivity 250 16 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 15 200 14 13 150 12 11 100 10 9
50 8
0 7 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 35. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples collected from well G-3608 and bulk conductivity measured at a depth of 28.9 meters, Biscayne aquifer, Miami-Dade County, Florida.
Sources of Saltwater in the Biscayne Aquifer 51 The following information supports the interpretation Water levels at well G-3608 are generally 0.09 to that the conductive water detected in well G-3608 and 0.14 m higher on average than at well G-896 (fig. 37). Even G-896 emanated from the Snapper Creek Canal. if density differences resulting from changes in salinity are
- The oxygen and hydrogen stable isotope compositions considered, this head differential indicates that groundwater in samples from well G-3608 consistently plotted flow would generally be towards the east from well G-3608 closely to those of samples from the C-2 (Snapper to well G-896, rather than in the other direction. If saltwater Creek) Canal (fig. 29B), but the stable isotope com- leaked from the Snapper Creek Canal at well G-3608, the positions of samples of well G-3609, located 1.8 km prevailing groundwater-flow direction potentially could south-southeast of well G-3608, and well G-3607, move saltwater toward well G-896. This movement would located 1.7 km north of well G-3608, consistently account for (1) the occasional influxes of saltwater observed plotted closer to the intersection of the LSWML with at well G-896; (2) the similarity in interpreted piston-flow the GMWL (fig. 29B). Well G-3609 is on the salt- ages of samples from wells G-896 and G-3608; (3) the water side of the saltwater front and is open to the elevated concentrations of SF6 in samples from wells G-896 encroaching saltwater front. and G-3608, relative to those of samples from G-3609; and (4) the oxygen and hydrogen stable isotope compositions
- The interpreted piston-flow ages of water samples of the samples from well G-896, which plot closer to those from wells G-896 and G-3608 are relatively young of the surface water samples from the Snapper Creek Canal compared to those of samples from wells G-3607 and than to those of the groundwater samples from wells G-3607 G-3609 (table 5). and G-3609.
- Water from the Snapper Creek Canal near well G-3608 had SF6 concentrations ranging from 9.39 pptv in Black Creek Canal December 2009 to 37.0 pptv in July 2009 (appendix 2, table 2-4). The SF6 concentrations in samples from The TSEMIL dataset collected from well G-3702 wells G-896 and G-3608 were within this range. (fig. 38A), located on the western bank of the Black Creek Conversely samples from nearby well G-3609, which Canal 3.9 km upstream from water control structure is open below the saltwater interface, contained S-21 (fig. 8), identified a shallow influx of conductive water only 0.79 to 0.93 pptv SF6, which is about an order that may have been caused by the leakage of saltwater from of magnitude less than that of samples from wells this canal. In the June 13, 2007, log of the TSEMIL dataset, G-896 and G-3608. in the depth interval 9.8 to 17 m, there was an abrupt increase in bulk conductivity. This increase may correspond to an None of the influxes of saltwater in the Snapper influx of water in the Black Creek Canal at station BL03 on Creek Canal correspond to the interpreted piston-flow age May 9, 2007, with a salinity of 14.5 PSU (fig. 39; Maria Idia determined for water sampled from well G-3608 (table 5), Macfarlane, Miami-Dade County Water and Sewer Depart-but monthly measurements may have failed to capture a ment, written commun., March 7, 2011; Craig Grossenbacher, short-term influx of saltwater in this canal upstream of S-22, Miami-Dade County Permitting, Environmental, and Regula-and the water sampled at G-3608 is likely a mixture of water tory Affairs, written commun., July 7, 2010) 1.9 km upstream of different ages, including a relatively young component.
of water control structure S-21 and 1.9 km downstream Another potential explanation for the occurrence of saltwater from well G-3702. A salinity of 14.5 PSU corresponds to a at well G-3608 is encroachment of saltwater through a chloride concentration of approximately 8,000 mg/L. The shallow preferential flow zone occurring in the aquifer. If salinity of the water in the canal on May 9, 2007, was one of the saltwater front in this area were moving westward, the the greatest measured at this site to date and was exceeded westward movement likely would be evident in samples from only by another influx of water with a salinity of 19.6 PSU on the 18.3- to 22.6-m depth interval of well G-896, 438 m October 3, 2007.
northeast of well G-3608 and 377 m east of the Snapper Creek Canal (fig. 8). The chloride concentrations in samples The EMI log collected in well G-3702 on May 6, 2008, from well G-896 increased to a maximum of 1,500 mg/L in indicated that the conductive water detected previously in June 1992; however, by April 1998, the chloride concentra- the 9.8- to 16.8-m depth interval had almost completely tion of water in well G-896 had declined to 380 mg/L, and dissipated. If any of this conductive water sank to the base of between April 1998 and May 2012, it gradually declined the aquifer, it does not appear to have had a lasting effect on to 260 mg/L (fig. 36). The influx of saltwater detected in the water chemistry and salinity at this location because of April 2003 at well G-3608 occurred approximately 11 years the following:
after the chloride concentrations in water samples from well
- Near the bottom of well G-3702 in the depth interval G-896 began declining. If the saltwater in well G-896 was 20 to 25 m, the TSEMIL dataset indicates a conductive associated with the saltwater front, it seems unlikely that the layer. There was a small increase in bulk conductiv-saltwater front could have advanced to the location of well ity in the depth interval 17 to 20 m, but below this G-3608 in 2003 when the samples from well G-896 indicate depth, the bulk conductivity of subsequent EMI logs that the saltwater front was probably retreating. decreased slightly (fig. 38A).
52 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 10,000 EXPLANATION G-3608 G-896 Chloride concentration, in milligrams per liter 1,000 100 10 1958 1960 1962 1964 1966 1968 1970 1972 1974 1976 1978 1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 Year Figure 36. Chloride concentrations in water samples from wells G-896 and G-3608, Miami-Dade County, Florida.
1.2 1.1 1.0 Water levels, in meters above NGVD 1929 0.9 0.8 0.7 0.6 0.5 EXPLANATION Linear regression (G-896) 0.4 Linear regression (G-3608)
G-896 0.3 G-3608 0.2 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 37. Water levels in wells G-896 and G-3608, 1996-2011, Miami-Dade County, Florida.
Sources of Saltwater in the Biscayne Aquifer 53 A
0 EXPLANATION G-3702 Electromagnetic induction logs This depth interval may have become 4/11/2000 5 contaminated with conductive water when the well was drilled. The 4/5/2001 conductive water appears to have 5/17/2002 slowly dissipated through time 5/2/2003 Depth, in meters below land surface 4/26/2004 There has been little change in bulk 4/14/2005 10 conductivity measured except in this 4/17/2006 depth interval in 2007 6/13/2007 5/6/2008 5/05/2009 15 4/9/2010 4/7/2011 Other than the year 2002, bulk conductivity measured and the chloride concentration of 20 samples from this well have remained about the same during the 12 years this well has been monitored 25 Screened 23.8 to 25.3 meters 0 20 40 60 80 100 120 140 160 Bulk conductivity, in millisiemens per meter B
2,200 100 EXPLANATION 2,000 Chloride concentration Bulk conductivity 1,800 90 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 1,600 1,400 1,200 80 1,000 800 600 70 400 200 0 60 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 38. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from well G-3702 and bulk conductivity measured at a depth of 24.6 meters, Biscayne aquifer, Miami-Dade County, Florida.
54 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 25 20 Salinity, in practical salinity units 15 10 5
0 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 39. Salinity of the Black Creek Canal at station BL03, 1991-2008 and 2010, Miami-Dade County, Florida.
- Well G-3702 is open to the aquifer in depth interval Princeton Canal 23.8 to 25.3 m. Water samples from this well indi-cate that the chloride concentration has been fairly Samples from monitoring well G-3162 (USGS constant at about 940 to 1,000 mg/L (fig. 38B) since ID 253202080232601) in the right of way of the Princeton salinity sampling began in 2002. Between June 2007 Canal (fig. 8) indicate that chloride concentrations and April 2011, chloride concentrations in this well increased from 160 to 1,300 mg/L between April 1978 and increased by only 40 mg/L. December 2011 (fig. 18) (U.S. Geological Survey, 2011f).
- The oxygen and hydrogen stable isotopic compositions Well G-3162 was not sampled during the present study of water from well G-3702 and the site C1 Canal at because well construction did not accommodate the types G-3702 do not plot close to each other (fig. 29B). of geochemical samples needed, but some of the informa-tion collected during this study indicates that the saltwater
- The SF6 concentrations in water samples from well sampled in this canal may have leaked from the canal, or G-3702 are 5.82 and 9.77 pptv, which are less than the encroached farther inland beneath the canal than on either SF6 concentration of 18.2 pptv in a sample from the canal (appendix table 2-4). side of the canal. USGS monitoring of the Princeton Canal between 1975 and 1978 at station Canal 102 at SW 107 Ave 3
H/3He age-dating of the sample from well near Homestead, FL (USGS ID 253108080215200) 1.8 km G-3702 indicated an apparent (piston flow) age of west of water control structure S-21A and 2.6 km east of
< 1970 (table 5). During the drought of 1960-63 water well G-3162, indicated two influxes of saltwater in the canal:
levels in long-term monitoring well S-182A, (USGS ID (1) between April and June 1975 with a maximum chloride 253549080214101) located 4.2 km north of well G-3702, declined to 0.20 m (U.S. Geological Survey, 2011f). This concentration of 1,300 mg/L, and (2) in March 1977 with water level was the 4th lowest water level recorded in this a chloride concentration of 2,080 mg/L (U.S. Geological well. During the 1943-57 drought, Black Creek was a stream Survey, 2011f). There is a gap of 13 years between the end of that extended from the coast to a little north of the location of USGS monitoring and the beginning of the salinity informa-well G-3702. The Black Creek Canal was dredged between tion provided by the M-D PERA (Maria Idia Macfarlane, April 1960 and December 1963 (Renken and others, 2005a). Miami-Dade County Water and Sewer Department, written These events may have allowed saltwater to leak from the commun., March 7, 2011; Craig Grossenbacher, Miami-canal as it was being dredged, or it may have encroached into Dade County Permitting, Environmental, and Regulatory the Biscayne aquifer during the drought of 1960-63. Affairs, written commun., July 7, 2010). In November 1993,
Sources of Saltwater in the Biscayne Aquifer 55 20 18 16 14 Salinity, in practical salinity units 12 10 8
6 4
2 0
1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 40. Salinity of the Princeton Canal at station PR03, 1991-2008 and 2010, Miami-Dade County, Florida.
a salinity of 18.3 PSU (fig. 40) was measured by the M-D Saltwater Encroachment PERA at station PR03 (fig. 8) near the same location where the USGS collected samples. This salinity is equivalent to The piston-flow ages and the recharge temperatures a chloride concentration of approximately 10,000 mg/L. of samples with a chloride concentration greater than or Salinities of 1.1, 2.4, 4.6, 7.6, 3.9, and 1.2 were measured in equal to about 1,000 mg/L generally correspond closely to a November 1996, February 1999, January 2005, August 2005, period with frequent droughts and the air temperatures that October 2005, and November 2008, respectively (fig. 40). are typical of the end of the dry season (figs. 30 and 31A),
These influxes of saltwater in the canal could account for when water levels in the aquifer reach a minimum (fig. 31B) an increase in salinity in the Biscayne aquifer adjacent to and saltwater encroachment along the base of the aquifer the canal. or saltwater leakage from canals is most likely to be at a TEM soundings MIA136 and MIA137 (fig. 8) collected maximum. Whether this saltwater encroached from the ocean 0.20 and 0.38 km south of the Princeton Canal, respectively, or bays, or leaked from canals, cannot be evaluated by using did not detect saltwater (appendix 4). Sounding MIA137 was these two geochemical relations alone. Differentiation of the collected 0.26 km east of the location of well G-3162. The source potentially can be made by using (1) results of the 2001 saltwater front is, therefore, at least 0.26 km farther inland HEM survey, (2) TSEMIL datasets, (3) results of long-term at the location of well G-3162 adjacent to the canal, than it monitoring of chloride concentrations (figs. 18 and 47) is 0.38 km south of the canal (fig. 8). This difference in the (U.S. Geological Survey, 2011f), and (4) information about inland extent of saltwater near the canal versus farther away other geochemical relations.
from the canal could potentially be caused by leakage of Resistivity data collected from each flight line of the saltwater from the Princeton Canal or encroachment under 2001 HEM survey (Fitterman and others, 2012) were used to the canal potentially caused by low freshwater levels caused create differential resistivity and inverted resistivity profiles.
by canal drainage. Many of these profiles intersected the saltwater front and EMI logs could not be collected from well G-3162; generally indicated a wedge-shaped mass of saltwater that therefore, the same kinds of observations made at wells extended about 9 to 15 km inland from the coast in the FKS8, G-3601, G-3608, and G-3702 could not be made for Biscayne aquifer. This wedge shape is typical of encroached this location. Also, it was not possible to collect a sample seawater (Brown and Parker, 1945). The wedge-like shape of for evaluation of the 3H/3He age. More information is encroaching saltwater is most evident in the eastern part of the needed to determine the source of the saltwater detected at HEM survey area (Fitterman and others, 2012). In the parts of well G-3162. the HEM survey area adjacent to the Card Sound Road Canal
56 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater and U.S. Highway 1, however, the slope of the intruded Although the TSEMIL datasets indicated that saltwater saltwater is almost vertical in some areas (Fitterman and is also encroaching near wells G-3601, G-3602, G-3604, and others, 2012). As discussed in the section Card Sound G-3605, the water samples from these wells did not indicate Road Canal, this is an area where saltwater has been the extent of ion depletion or enrichment observed in the other interpreted to have leaked from the canal and the old railway wells (figs. 19, 21-26). The lack of enrichment or depletion borrow ditch. is typical of areas of preexisting saltwater intrusion. Wells TSEMIL datasets can be used to evaluate the depth G-3604 and G-3605 are just south of the Tamiami and Miami intervals in which changes in the electrical conductivity of Canals where historical saltwater intrusion had occurred water are occurring. If a wedge-shaped body of saltwater (Parker and others, 1955); therefore, many of the ion exchange encroaches along the base of the aquifer, the first indication sites in this portion of the aquifer may have been filled when of encroachment at a given monitoring well is generally an saltwater previously intruded this area. Historical saltwater increase in bulk conductivity and chloride concentration near intrusion also has been documented (Parker and others, 1955) in the aquifer near wells G-3601 and G-3602, which are close the base of the aquifer. As saltwater continues to encroach, to the Biscayne and Little River Canals, respectively.
bulk conductivity and chloride concentration near the base The increases in measured bulk conductivity and chloride of the aquifer would increase, and the depth to the top of the concentration in well G-3698 may have resulted from saltwater interface would decrease. Such changes are evident saltwater encroachment, or they may be the direct or indirect in the TSEMIL datasets from 12 wells: G-3604 (fig. 41A),
results of leakage of saltwater from a canal. Well G-3698 G-3605 (U.S. Geological Survey, 2011g), G-3609 (fig. 42A),
is a few meters from a small canal that leads to the Mowry G-3615 (U.S. Geological Survey, 2011g), G-3698 (fig. 43A),
Canal. The sudden increase in bulk conductivity observed in G-3699 (fig. 44A), G-3704 (U.S. Geological Survey, 2011g),
G-3705 (U.S. Geological Survey, 2011g), G-3855 (fig. 46A), the TSEMIL dataset from this well throughout a 12-m-thick G-3856 (fig. 46B), and the deeper parts of wells G-3601 portion of the aquifer (fig. 43A) and the sudden increase and (fig. 32A) and G-3602 (fig. 45A). Long-term sampling of wells subsequent decrease in the chloride concentration in samples G-3601 (fig. 32B), G-3602 (fig. 45B), G-3604 (fig. 41B), collected from this well (fig. 18) are unusual. The changes G-3605 (fig. 18), G-3609 (fig. 42B), G-3615 (fig. 47), at well G-3698 are similar in some ways to the shallow G-3698 (fig. 43B), G-3699 (fig. 44B), G-3704 (fig. 47), and and short-term influxes of conductive water detected in the G-3705 (fig. 47) indicates that the chloride concentration has TSEMIL datasets from wells G-3601 (fig. 32A), G-3608 increased in water samples from these wells. (fig. 35A), and G-3702 (fig. 38A), where canal leakage is a Long-term chloride sampling and/or TSEMIL datasets likely factor. Saltwater has been detected in the past in the indicated that saltwater was actively encroaching near the Mowry Canal at structure S-179 near well G-3698. Eighteen base of the Biscayne aquifer in 12 wells (figs. 19, 21-26). percent of samples from the Mowry Canal on the downstream Geochemical sampling indicated the recent onset of saltwater side of structure S-179 during 1972 to 1979 indicated chloride intrusion in six of the wells (G-3615, G-3698, G-3699, concentrations ranging from 740 to 7,200 mg/L (4 to 40 PSU)
G-3704, G-3705, and G-3855) and ongoing saltwater (U.S. Geological Survey, 2011f). USGS sampling of the site encroachment in four of the wells (G-3601, G-3602, was discontinued in November 1979. Monthly measure-G-3604, and G-3605). Results were inconclusive in two ments of salinity during July 1991 to December 2008 and wells (G-3856 and G-3609). ). The recent onset of saltwater January 2010 to November 2010 at the bottom of the Mowry intrusion near wells G-1264 (fig. 18), G-3615 (fig. 47), Canal at site MW04 (fig. 48), 3.3 km upstream of water G-3698 (fig. 43B), G-3699 (fig. 44B), and G-3705 (fig. 47) control structure S-20F and 3.5 km downstream of S-179, was confirmed by long-term monitoring, indicating that the indicate that about 12 percent of the measurements had a chloride concentrations in samples increased from less than salinity of 4.3 to 23 PSU. At least some of the saltwater may 1,000 mg/L to greater than 1,000 mg/L sometime during have leaked from this canal. Whether the saltwater detected or after 1994. The chloride concentration in well G-3704 at well G-3698 leaked from the canal or encroached along (fig. 47) increased from 3,400 to 6,800 mg/L during April the base of the aquifer, or both, is uncertain given existing 2006 to April 2011. It is uncertain when the saltwater front geochemical evidence. The interpreted piston-flow age of passed this well, but it may have occurred fairly recently based the sample from well G-3698 is about 1986 (table 5), which on the rate at which salinity in this well increased. corresponds to a period with frequent droughts.
TSEMIL datasets were not collected from wells F-279, G-901, and G-1264. Each of these wells is shallower than the base of the Biscayne aquifer, but the evaluation of trace and major ions in the wells indicated that saltwater had Limitations recently intruded the aquifer at the sampling depths of these three locations (figs. 19, 21-26). Long-term monitoring The accuracy of the map showing the inland extent of indicates that the chloride concentration of sampled water saltwater in the Biscayne aquifer in 2011 (figs. 8, 17) can be increased to greater than 1,000 mg/L in 1959 at well F-279 evaluated by considering the spatial coverage of monitoring (fig. 47), in 1994 at well G-901 (fig. 47), and in 2003 at well wells and TEM soundings used to create the map (fig. 8).
G-1264 (fig. 18). The TEM soundings MIA105 and MIA106 (fig. 8), for
Limitations57 A
-3 EXPLANATION G-3604 electromagnetic 2 induction logs 8/29/1995 1/17/1996 7 5/13/1996 4/21/1997 Depth, in meters below land surface 4/3/1998 12 4/12/1999 4/13/2000 4/6/2001 17 5/14/2002 4/28/2003 4/21/2004 22 4/18/2005 9/13/2006 6/15/2007 27 5/02/2008 5/11/2009 4/20/2010 32 4/25/2011 Screened 37 35.0 to 36.6 meters 0 50 100 150 200 250 300 350 400 Bulk conductivity, in millisiemens per meter B
5,500 350 330 5,000 310 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 290 4,500 270 4,000 250 230 3,500 210 190 3,000 EXPLANATION Chloride concentration 170 Bulk conductivity 2,500 150 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 41. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3604 and bulk conductivity measured at a depth of 34.7 meters, Biscayne aquifer, Miami-Dade County, Florida.
58 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3609 2 electromagnetic induction logs 4 This spike did not occur prior to the log 1/17/1996 of April 2003. There is a gap around the 5/24/1996 casing to a depth of about 9 feet.
6 Something conductive may have fallen 4/23/1997 into this gap 4/1998 Depth, in meters below land surface 8 4/9/1999 4/13/2000 10 4/06/2001 This depth interval may have become 5/20/2002 contaminated with conductive water 12 when the well was drilled. The 4/30/2003 conductive water appears to have 4/23/2004 14 slowly dissipated, and bulk conductivity 4/27/2005 in this depth interval has remained 4/24/2006 relatively constant since 2002 16 6/14/2007 4/30/2008 18 5/06/2009 4/13/2010 20 2009, 2010 4/21/2011 1997 2011 22 1996 Screened 24 24.4 to 25.9 meters 0 10 20 30 40 50 60 70 80 Bulk conductivity, in millisiemens per meter B
1,600 50 1,500 1,400 45 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 1,300 1,200 40 1,100 1,000 35 900 800 30 EXPLANATION Chloride concentration 700 Bulk conductivity 600 25 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 42. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3609 and bulk conductivity measured at a depth of 22.7 meters, Biscayne aquifer, Miami-Dade County, Florida.
Limitations59 A
0 EXPLANATION G-3698 electromagnetic induction logs Variations in bulk conductivity near the land 4/11/2000 5
surface are observed in most log sets. One 4/4/2001 possible explanation is that these variations 5/16/2002 are caused by variations in water temperature 4/25/2003 Depth, in meters below land surface near the land surface 4/20/2004 10 4/19/2005 4/18/2006 6/17/2007 Prior to April 2010, below a depth of 10 feet, the 4/29/2008 adjusted logs only differed from each other by 4/29/2009 approximately 2 millisiemens per meter 15 4/7/2010 2010 4/5/2011 2011 20 25 Screened 24.4 to 25.9 meters 0 15 30 45 60 75 90 105 120 135 150 Bulk conductivity, in millisiemens per meter B
94 EXPLANATION 2,000 Chloride concentration 84 Bulk conductivity Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 74 1,500 64 1,000 54 44 500 34 0 24 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 43. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3698 and bulk conductivity measured at a depth of 24.5 meters, Biscayne aquifer, Miami-Dade County, Florida.
60 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3699 2
electromagnetic induction logs 4
4/18/2000 4/4/2001 6
5/15/2002 Depth, in meters below land surface 8 4/25/2003 4/19/2004 10 4/19/2005 These depth intervals may have become 4/18/2006 12 contaminated with conductive water 6/12/2007 when the well was drilled. The conductive 4/28/2008 14 water appears to have slowly dissipated, and bulk conductivity in this depth interval 4/28/2009 has remained relatively constant since 2005 04/06/2010 16 04/04/2011 18 20 2011 22 24 2000 26 Screened 0 50 100 150 200 250 300 350 400 450 500 25.3 to 26.8 meters Bulk conductivity, in millisiemens per meter B
12,000 500 450 10,000 400 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 350 8,000 300 6,000 250 200 4,000 150 100 2,000 EXPLANATION Chloride concentration 50 Bulk conductivity 0 0 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 44. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3699 and bulk conductivity measured at a depth of 25.3 meters, Biscayne aquifer, Miami-Dade County, Florida.
Limitations61 A
0 EXPLANATION G-3602 5 electromagnetic induction logs 1/9/1996 10 5/13/1996 4/21/1997 4/20/1998 Depth, in meters below land surface 15 4/12/1999 4/2000 20 4/11/2001 5/13/2002 25 4/29/2003 4/22/2004 4/25/2005 30 4/25/2006 6/19/2007 35 5/07/2008 5/11/2009 4/21/2010 40 4/26/2011 45 Screened 47.2 to 48.8 meters 0 50 100 150 200 250 300 350 400 450 500 Bulk conductivity, in millisiemens per meter B
4,500 140 135 130 4,000 125 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 120 115 3,500 110 105 3,000 100 95 90 2,500 EXPLANATION 85 Chloride concentration 80 Bulk conductivity 2,000 75 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 45. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3602 and bulk conductivity measured at a depth of 46.9 meters, Biscayne aquifer, Miami-Dade County, Florida.
62 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3855 electromagnetic 5 induction logs 11/21/2007 2/26/2008 Depth, in meters below land surface 4/28/2008 10 15 The depth to the saltwater interface decreased by 0.6 meter between November 21, 2007, and 20 February 26, 2008, and by another 0.4 meter between February 26, 2008, and April 28, 2008 25 Screened 25.0 to 26.5 meters 0 25 50 75 100 125 150 Bulk conductivity, in millisiemens per meter B
0 EXPLANATION G-3856 electromagnetic 5 induction logs 11/21/2007 2/26/2008 Depth, in meters below land surface 4/28/2008 10 15 The depth to the saltwater interface decreased by 1 meter between 20 November 21, 2007, and February 26, 2008 25 Screened 24.4 to 25.9 meters 0 10 20 30 40 50 60 70 80 90 100 Bulk conductivity, in millisiemens per meter Figure 46. Time-series electromagnetic induction log (TSEMIL) datasets from monitoring wells (A) G-3855 and (B) G-3856 for November 2007 to April 2008, Biscayne aquifer, Miami-Dade County, Florida
Chloride concentration, in milligrams per liter 5,000 4,500 4,000 3,500 3,000 3,500 3,000 2,500 2,500 2,000 2,000 1,500 1,000 1,500 1,000 500 0 500 0
1950 1952 1954 1956 G-3615 G-901 1958 1960 Salinity, in practical salinity units 1962 1964 0 5 10 15 20 25 1966 1968 1988 1970 1972 1989 1974 1976 1978 1990 Chloride concentration, 1980 Year 1982 1991 in milligrams per liter 1984 3,500 3,000 2,500 2,000 1986 1,500 1,000 1992 500 0 1988 1950 1990 1993 1952 1992 1954 1994 1994 1956 G-3705 1996 1958 1998 1960 2000 1995 2002 1962 1964 2004 1996 1966 2006 1968 2008 1997 1970 2010 1972 2012 1998 1974 1976 Figure 48. Salinity of the Mowry Canal at station MW04, 1991-2009 and 2010, Miami-Dade Figure 47. Chloride concentrations in samples from 1999 1978 Chloride concentration, in milligrams per liter Year 1980 8,000 4,500 7,000 6,000 5,000 4,000 3,500 3,000 Year 1982 4,000 3,000 2,500 2,000 1,500 2000 2,000 1,000 0 1,000 500 0
1984 1986 1950 2001 1952 1988 1990 1954 2002 1992 1956 F-279 G-3704 1994 1958 2003 1996 1960 1998 1962 2004 2000 1964 2002 1966 2005 2004 1968 2006 1970 monitoring wells, Miami-Dade County, Florida.
2008 1972 2006 1974 2010 2012 1976 2007 1978 1980 2008 Year 1982 1984 2009 1986 1988 2010 1990 County, Florida.
1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 Limitations63
64 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater example, are only 120 m apart; therefore, the inland extent Movement of the saltwater front is an ongoing of saltwater was narrowly constrained at this location. TEM phenomenon. The data collected for this study spanned sounding MIA106 indicated freshwater in the Biscayne 4 years, and during that time, many of the wells were actively aquifer, whereas MIA105 indicated saltwater in the aquifer monitored; as a result, the most recent information was (appendix 4). In general, however, the map was not this used to produce the maps of the inland extent of saltwater narrowly constrained. Near monitoring wells G-3229 and in 2008 and 2011. TEM soundings were completed during a G-3888 (fig. 8), no other actively monitored wells are on the 2-year period, however, and provided spatial coverage where western side of the saltwater front to constrain the determina- there were no existing data; therefore, in some locations, the tion of its inland extent. The saltwater front (1,000 mg/L extent of the saltwater front may have already changed by the time the 2011 map (fig. 8) was created. In addition, the HEM isochlor) had passed the location of well G-3229 between survey that was calibrated and published in 2012 (Fitterman October 13, 2009, and December 15, 2009 (fig. 18). By and others) had been collected in 2001. If a new HEM survey February 2011, the chloride concentration in samples from had been collected during this study, it potentially could G-3229 had increased to 1,500 mg/L (fig. 18). Generally, the have been calibrated using the TEM soundings collected precision and accuracy of the map showing the inland extent in 2009, which would have provided a direct comparison of of saltwater in the Biscayne aquifer ranged from about +/-50 m the 2001 survey with a more recent survey.
to +/- 1 km, and the line showing the inland extent of saltwater Additional samples for 3H/3He age dating could increase in the Biscayne aquifer is referred to as approximate the understanding of the sources of saltwater and the move-whenever referenced in a map. Some active monitoring wells, ment of saltwater and freshwater in the aquifer. SF6 data could such as well G-1351 (fig. 8 and appendix 1) were too shallow potentially have provided spatially distributed age dating to fully evaluate the extent of saltwater within the Biscayne information, but excess SF6 in the aquifer prevented the use of aquifer. A few active monitoring wells, such as wells F-279 this method. Analyses of the ages of samples were based on and G-3313C (fig. 8 and appendix 1) have long open the assumption of piston flow because there was insufficient intervals that may be susceptible to ambient borehole flow, information to evaluate the potential mixing of younger and which may reduce the quality of salinity measurements in the older water at each location. The piston-flow assumption may aquifer at these locations. not be valid because most of the samples were collected from Most of the active monitoring wells and the TEM near the freshwater/saltwater interface where mixing likely measurements were near the leading edge of the saltwater occurred. This mixing may have affected the ages determined front. The thickness of the saltwater front throughout the for some samples; however, if old tritium-free water were aquifer cannot be fully evaluated by using active monitoring mixed with young water, the age determined could still be accurate because tritium/helium age dating is based on an or TEM measurements. Additional monitoring, including TEM isotopic ratio (Plummer and others, 2003).
soundings and TSEMIL datasets, could allow mapping of the saltwater interface in three dimensions if collected between the leading edge of the saltwater front and the ocean. The HEM survey data collected in 2001 (figs. 1 and 16) provided Summary and Conclusions detailed three-dimensional information (Fitterman and others, 2012) concerning the distribution of saltwater, but the In Miami-Dade County, the principal source of drinking survey was limited to a small part of the county. water is the Biscayne aquifer. Prior to development, the esti-Many of the monitoring wells do not extend beyond mated level of freshwater (3 to 4.3 m) in the Everglades near the base of the Biscayne aquifer, so the depth or occurrence Miami was likely sufficient to prevent saltwater encroachment of saltwater intrusion may be uncertain. Some of the TEM in the Biscayne aquifer in this area. The head differential soundings detected saltwater in the surficial aquifer below the between the Everglades and the coast was evidenced by base of the Biscayne aquifer (Fitterman and Prinos, 2011), and numerous freshwater springs that flowed near the coast line some indicated freshwater throughout the surficial aquifer. and boiled up in Biscayne Bay. Beginning in 1845, drainage The eight new monitoring wells extend below the base of canals effectively drained the Everglades and resulted in an estimated 2.9-m permanent reduction in Biscayne aquifer the Biscayne aquifer to monitor saltwater within part of the water levels in east-central Miami-Dade County, which surficial aquifer system, but the spatial coverage of wells and allowed saltwater to encroach landward along the base of the soundings that can evaluate salinity below the base of the Biscayne aquifer. Landward encroachment was exacerbated Biscayne aquifer is limited. during drought periods when water levels in the aquifer fell to Additional monitoring in and near canals is needed to or below sea level. Saltwater also flowed inland up the canals better understand the potential effects of saltwater leakage and into the Biscayne aquifer. Water control structures on most from canals. Continuous salinity monitoring in canals, and in of the major drainage canals in Miami-Dade County reduced, wells adjacent to the canals, could help quantify the amount but did not completely eliminate, the ability of saltwater to of saltwater leaking from these canals upstream of the salinity flow inland through these canals during drought periods.
control structures. Additional TEM soundings, resistivity The various pathways of seawater into the highly permeable surveys, or monitoring wells could be used to better delineate Biscayne aquifer have combined to intrude approximately the inland extent of saltwater near canals. 1,200 km2 of this aquifer with saltwater.
Summary and Conclusions 65 To map the inland extent of saltwater in the Biscayne water with chloride concentrations less than about 1,000 mg/L aquifer, the following data were compiled and analyzed: (1) all indicate recharge temperatures corresponding to air tempera-available salinity information, (2) TSEMIL datasets from tures in mid to late May when water levels in the aquifer begin 35 wells that were processed using a newly developed method, to increase, and the piston-flow age determinations correspond (3) TEM soundings collected at 79 locations in 2008 and 2009 to wet years. The piston-flow ages of freshwater samples were and used to evaluate the depth to saltwater (if present) and the generally younger than ages determined for saltwater.
depth to the base of the Biscayne aquifer, (4) a HEM survey The silica concentrations in samples from well G-3701 collected in 2001 that was processed and interpreted during indicate that this well is screened in the Pinecrest Sand this study, (5) cores and geophysical logs collected from Member of the Tamiami Formation below the base of the 8 sites for stratigraphic analysis, (6) analyses of samples from Biscayne aquifer. Samples from the wells G-3600 and 8 new single or multi-depth monitoring wells installed in these G-3601, which are screened in a part of the Biscayne aquifer core holes, and (7) analyses of 69 geochemical samples. These that includes the Tamiami Formation, also indicated silica data were evaluated, and GIS software was used to map the concentrations that were elevated relative to samples from inland extent of saltwater in the Biscayne aquifer in 2008 and most other wells.
in 2011. The strontium (87Sr/86Sr) isotope ratio in samples was The saltwater front was mapped farther inland than it used to evaluate the origin of saltwater in the Biscayne aquifer, was in 1995 in eight approximated areas totaling 24.1 km2, but the method did not prove useful because the standard error most notably near the Florida City Canal where the front had was too large relative to the range of the 87Sr/86Sr isotope ratios advanced by as much as 1.9 km between 1995 and 2011. The in the study area. Most of the 87Sr/86Sr isotope ratios deter-saltwater interface was mapped closer to the coast than it mined from samples corresponded with the Pleistocene age was in 1995 in four approximated areas totaling 6.2 km2. The of most sediments in the Biscayne aquifer. Two of the lowest saltwater interface was mapped closer to the coast near the ratios were observed for samples from wells G-3701 and Snapper Creek Canal than it had been in 1995. Some revisions G-3601. These wells likely are open to materials that are of to the saltwater interface were the result of the improved Pliocene age.
spatial coverage provided by additional wells, TEM sound- Oxygen and hydrogen isotopes indicated that water from well G-3608 was similar in isotopic composition to ings, and the HEM survey. One area with extensive revisions water from the adjacent Snapper Creek Canal. The relatively resulting primarily from improved spatial coverage was near shallow increase in bulk conductivity evident in the TSEMIL the Card Sound Road Canal and U.S. Highway 1.
dataset from G-3608, the interpreted piston-flow age of water The sources and changes in the distribution of from this well, and the local hydraulic gradient indicated that saltwater in the Biscayne aquifer were evaluated by using the saltwater at this location likely emanated from seawater (1) geochemical sampling, (2) salinity measurements collected that had flowed up the Snapper Creek Canal and leaked into in canals, and (3) TSEMIL datasets. A total of 69 geochemical the aquifer.
water samples were collected from 44 sites. Analyses Geochemical analyses had indicated preexisting saltwater included (1) major ion chemistry and trace ion chemistry, intrusion at wells G-3600, G-3601, G-3602, G-3604, and (2) strontium isotope ratios, (3) oxygen and hydrogen isotope G-3605. The highest tritium concentrations (3.2 to 53.3 TU) ratios, (4) tritium concentration, (5) tritium/helium-3 (3H/3He) measured during the study were measured in water from age dating, (6) sulfur hexafluoride (SF6) age dating, and wells FKS4, FKS7, G-1264, G-3698, G-3699, G-3855, and (7) dissolved gas composition. G-3856. These seven wells are within 10 km of the Turkey The results of geochemical analyses indicate that Point Nuclear Power Plant, and hypersaline water with high saltwater intrusion has recently arrived at wells G-1264, tritium concentrations from the cooling canals may be contrib-G-3615, G-3698, G-3699, G-3704, G-3705, and G-3855. uting to saltwater encroachment near the wells. Geochemical Long-term records of chloride concentration confirm that the analyses and long-term monitoring data from wells G-1264, saltwater interface (1,000 mg/L) first became evident at most G-3698, G-3699, G-3855, and G-3856 confirmed the recent of these locations during or after 1994. Geochemical analyses arrival of saltwater intrusion.
at wells FKS4, FKS8, G-939, G-3600, G-3601, G-3602, 3 H/3He age dating indicated that the water sampled G-3604, and G-3605 generally indicate preexisting saltwater from wells G-3601 and G-3701 contained too little tritium intrusion as reported by previous researchers. to be evaluated using this method. The sample from well Droughts and intruded saltwater are closely connected. G-3600 showed the characteristics of gas fractionation The piston-flow ages determined from 3H/3He age samples of and could not be dated using 3H/3He age dating. Water saltwater with a chloride concentration of about 1,000 mg/L or samples from wells G-3600, G-3601, G-3602, G-3604, and greater generally correspond to a period of frequent droughts. G-3701 also indicated silica concentrations that were greater Recharge temperatures of water samples determined by using than the theoretical mixing of freshwater and saltwater in dissolved-gas analyses are consistent with air temperatures the area would produce. These elevated silica concentrations that occur in April or early May, when water levels are could be caused by relatively longer residence times within a typically at their lowest. Conversely, most of the samples of quartz-sand-rich formation.
66 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater SF6 age dating could not be used effectively in the study Bearden, H.W., 1974, Groundwater resources of the Holly-area principally because there was excess SF6 in most samples wood area, Florida: State of Florida, Department of Natural that may have been caused by leakage of SF6 from electrical Resources, Division of Interior Resources, Bureau of Geol-switching facilities. Moreover, SF6-interpreted piston-flow ogy, Report of Investigations no. 77, 35 p.
ages are generally younger than 3H/3He ages. The lowest SF6 concentrations determined were for water sampled from wells Begemann, Friedrich, and Friedman, Irving, 1959, Tritium and G-3601 and G-3701. These samples also contained no tritium. deuterium content of atmospheric hydrogen: Zeitschrift für Evaluations of long-term chloride monitoring and the Naturforschung, v. 14a, p. 1024.
geochemistry of water samples indicated that the saltwater Benson, M.A., and Gardner, R.A., 1974, The 1971 drought sampled in the Biscayne aquifer is likely not relict seawater in South Florida and its effect on the hydrologic system:
of Pleistocene or Pliocene ages. Some saltwater likely leaked U.S. Geological Survey Water-Resources Investigations from canals prior to the installation of water control structures. Report 74-12, p. 35-37.
Near the Miami Canal northwest of the water control structure S-26, this saltwater is gradually mixing with the groundwater, Bridges, W.B., Franklin, M.A., and Fleeson, T.A., 1991, Flor-and salinity is gradually decreasing. Modern leakage of ida floods and droughts in Paulson, R.W., and others, eds.,
saltwater likely is occurring along the Card Sound Road Canal National Water Summary 1988-89Hydrologic events and and upstream of salinity control structures in the Biscayne, floods and droughts: U.S. Geological Survey Water-Supply Black Creek, and Snapper Creek Canals. Saltwater also may Paper 2375, p. 231-238.
have leaked from the Princeton Canal and the canal adjacent to well G-3698, although this leakage could not be confirmed Brown, J.S., 1925, A study of coastal ground water, with or refuted with available information. special reference to Connecticut: U.S. Geological Survey Additional information, such as TEM soundings or Water-Supply Paper 537, p. 16-17.
resistivity surveys collected from the canals and monitoring wells Brown, R.H., and Parker, G.G., 1945, Salt water encroachment adjacent to these canals, could be used to evaluate the effect that in limestone at Silver Bluff, Miami, Florida: Economic saltwater leakage around or through existing structures has on Geology, v. 60, no. 4, p. 235-262.
the inland extent of saltwater in the Biscayne aquifer. Influxes of saltwater in canals may be undetected because the interval Busenberg, Eurybiades, and Plummer, L.N., 2000, Dat-between samples is too long. Continuous salinity monitoring in ing young groundwater with sulfur hexafluoride: Natural canals could be useful in the detection of any future influxes of and anthropogenic sources of sulfur hexafluoride: Water saltwater upstream of existing water control structures. Resources Research, v. 36, p. 3011-3030.
Busenberg, Eurybiades, Plummer, L.N., Doughten, M.W.,
Widman, P.K., and Bartholomay, R.C., 2000, Chemical Selected References and isotopic composition and gas concentrations of ground water and surface water from selected sites at and near the Aeschbach-Hertig, W., Peeters, F., Beyerle, U., and Kipfer, R., Idaho National Engineering and Environmental Labora-1999, Interpretation of dissolved atmospheric noble tory, Idaho, 1994-97: U.S. Geological Survey Open-File gases in natural waters: Water Resources Research, v. 35, Report 00-81, 51 p.
- p. 2779-2792.
Busenberg, Eurybiades, Weeks, E.P., Plummer, L.N., and Bar-Aeschbach-Hertig, W., Peeters, F., Beyerle, U., and Kipfer, R., tholemay, R.C., 1993, Age dating ground water by use of 2000, Paleotemperature reconstruction from noble gases chlorofluorocarbons (CC13F and CC12F2), and distribution in ground water taking into account equilibration with of chlorofluorocarbons in the unsaturated zone, Snake River entrapped air: Nature, v. 405, p. 1040-1044. Plain aquifer, Idaho National Engineering laboratory, Idaho:
U.S. Geological Survey Water-Resources Investigations Anderson, P.F., Mercer, J.W., and White, H.O., 1988, Numeri- Report 93-4054, 47 p.
cal modeling of salt-water intrusion at Hallandale, Florida:
Ground Water, v. 26, no. 5, p. 619-633. Causaras, C.R., 1987, Geology of the surficial aquifer system, Dade County, Florida: U.S. Geological Survey Water-ASTM International, 2007, Standard guide for conducting Resources Investigations Report 86-4126, 240 p., 2 sheets.
borehole geophysical loggingelectromagnetic induction:
ASTM International D 6726-01 (reapproved 2007), 8 p. Clesceri, L.S., Greenburg, A.E., and Eaton, A.D., eds., 1998, Standard methods for the examination of water and waste-Barlow, P.M., 2003, Ground water in freshwater-saltwater water (20th ed.): Washington, D.C., American Public Health environments of the Atlantic Coast: U.S. Geological Survey Association, American Water Works Association, and Water Circular 1262, 113 p. Environment Federation, p. 3-37 to 3-43.
Selected References67 Craig, Harmon, 1961, Standard for reporting concentrations of Cunningham, K.J., Wacker, M.A., Robinson, Edward, Dixon, deuterium and oxygen-18 in natural waters: Science, v. 133, J.F., and Wingard, G.L., 2006b, A cyclostratigraphic
- p. 1833-1834. and borehole geophysical approach to development of a three-dimensional conceptual hydrogeologic model of the Cross, W.P., and Love, S.K., 1942, Groundwater in southeast- karstic Biscayne aquifer, southeastern Florida: U.S. Geo-ern Florida: Journal of the American Water Works Associa- logical Survey Scientific Investigations Report 2005-5235, tion, v. 34, no. 4, p. 490-504.
75 p., 4 sheets.
Cunningham, K.J., Bukry, D., Sato, T., Barron, J.A., Guertin, Davis, S.N., Whittemore, D.O., and Fabryka-Martin, L.A., and Reese, R.S., 2001, Sequence stratigraphy of a June, 1998, Uses of chloride/bromide ratios in studies of south Florida carbonate ramp and bounding siliciclastics potable water: Ground Water, v. 36, no. 2, p. 338-350.
(late Miocene-Pliocene), in Missimer, T.M., and Scott, T.M., eds., Geology and hydrology of Lee County: Florida Federal Register Notice, 1979, October 11, 1979, v. 44, no. 198.
Geological Survey Special Publication 49, p. 35-66.
Fish, J.E., 1988, Hydrogeology, aquifer characteristics, and Cunningham, K.J., Carlson, J.L., Wingard, G.L., Robinson, groundwater flow of the surficial aquifer system, Broward Edward, and Wacker, M.A., 2004, Characterization of aqui- County, Florida: U.S. Geological Survey Water-Resources fer heterogeneity using cyclostratigraphy and geophysical Investigations Report 87-4034, 80 p.
methods in the upper part of the karstic Biscayne aquifer, southeastern Florida: U.S. Geological Survey Water- Fish, J.E., and Stewart Mark, 1991, Hydrogeology of the surfi-Resources Investigations Report 03-4208, 46 p. cial aquifer system, Dade County, Florida: U.S. Geological Survey Water-Resources Investigations Report 90-4108, Cunningham, K.J., Locker, S.D., Hine, A.C., Bukry, D., 50 p., 11 sheets.
Barron, J.A., and Guertin, L.A., 2003, Interplay of late Cenozoic siliciclastic supply and carbonate response on Fishman, M.J., ed., 1993, Methods of analysis by the U.S.
the southeast Florida Platform: Journal of Sedimentary Geological Survey National Water Quality Laboratory Research, v. 73, no. 1, p. 31-46. Determination of inorganic and organic constituents in water and fluvial sediments: U.S. Geological Survey Open-Cunningham, K.J., McNeill, D.F., Guertin, L.A., Ciesielski, File Report 93-125, 217 p.
P.F., Scott, T.M., and de Verteuil, L., 1998, New Tertiary stratigraphy for the Florida Keys and southern peninsula Fishman, M.J., and Friedman, L.C., 1989, Methods for of Florida: Geological Society of America Bulletin, v. 110, determination of inorganic substances in water and fluvial no. 2, p. 231-258. sediments: U.S. Geological Survey Techniques of Water-Resources Investigations, book 5, chap. A1, 545 p.
Cunningham, K.J., Renken, R.A., Wacker, M.A., Zygnerski, M.R., Robinson, E., Shapiro, A.M., and Wingard, G.L., Fitterman, D.V., 1989, Detectability levels for central induc-2006a, Application of carbonate cyclostratigraphy and bore- tion transient soundings: Geophysics, v. 54, p. 127-129.
hole geophysics to delineate porosity and preferential flow in the karst limestone of the Biscayne aquifer, SE Florida, Fitterman, D.V., and Deszcz-Pan, Maria, 1998, Helicopter EM in Harmon, R.S., and Wicks, C., eds., Perspectives on karst mapping of saltwater intrusion in Everglades National Park:
geomorphology, hydrology, and geochemistryA tribute Florida Exploration Geophysics, v. 29, p. 240-243.
volume to Derek C. Ford and William B. White: Geological Fitterman, D.V., and Deszcz-Pan, Maria, 2002, Helicopter Society of America Special Paper 404, p. 191-208.
electromagnetic data from Everglades National Park and Cunningham K.J., Sukop, M.C., Huang, H., Alvarez, P.F., Cur- surrounding areas, FloridaCollected 9-14 December ran, H.A., Renken, R.A., and Dixon, J.F, 2009a, Prominence 1994: U.S. Geological Survey Open-File Report 2002-101, of ichnologically influenced macroporosity in the karst Bis- 1 CD-ROM.
cayne aquiferStratiform super K zones: GSA Bulletin,
- v. 121, no. 1/2, p. 164-180. Fitterman, D.V., Deszcz-Pan, Maria, and Prinos, S.T., 2012, Helicopter electromagnetic survey of the Model Land Area, Cunningham, K.J., and Wacker, C., 2009, Seismic-sag struc- southeastern Miami-Dade County, Florida: U.S. Geological tural systems in Tertiary carbonate rocks beneath south- Survey Open-File Report 2012-1176, 75 p., 1 app.
eastern Florida, USAEvidence for hypogenic speleogen-esis? in Klimchouk, A.B., and Ford, D.C., eds., Hypogene Fitterman, D.V., Deszcz-Pan, Maria, and Stoddard, C.E., 1999, speleogenesis and karst hydrogeology of artesian basins: Results of time-domain electromagnetic soundings in Ever-Simferopol, Ukraine, Ukrainian Institute of Speleology and glades National Park, Florida (on CD-ROM): U.S. Geologi-Karstology, Special Paper no. 1, p. 151-158. cal Survey Open-File Report 99-426, 152 p.
68 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Fitterman, D., and Labson, V.F., 2005, Electromagnetic Garbarino, J.R., Kanagy, L.K., and Cree, M.E., 2006, Determi-induction methods for environmental problems, in Butler, nation of elements in natural-water, biota, sediment, and soil D.K., ed., Near-surface geophysics, part 1Concepts and samples using collision/reaction cell inductively coupled fundamentals: Tulsa, Society of Exploration Geophysicists, plasma-mass spectrometry: U.S. Geological Survey Tech-
- p. 295-349. niques and Methods, book 5, sec. B, chap. 1, 88 p.
Fitterman, D.V., and Prinos, S.T., 2011, Results of time- Geonics Limited, 2006, Protem 47D operating manual for domain electromagnetic soundings in Miami-Dade and 20/30 gate model: Geonics Limited, 80 p.
southern Broward Counties, Florida: U.S. Geological Survey Open-File Report 2011-1299, 289 p. Guertin, L.A., 1998, A late Cenozoic mixed carbonate/silici-clastic system, south FloridaLithostratigraphy, chro-Fitterman, D.V., and Stewart, M.T., 1986, Transient electro- nostratigraphy, and sea-level record: Miami, University of magnetic sounding for groundwater: Geophysics, v. 51, Miami, Ph.D. dissertation, 335 p.
- p. 995-1005.
Ghyben, W.B., 1889, Nota in verband met de voorgenomen Fletcher, D.U., 1911, Everglades of FloridaActs, reports and putboring nabij Amsterdam; K. Inst Ing. Tijdschr, 1888-89, other papers State and National, relating to the Everglades p. 21.
of the State of Florida and their reclamation: Washington, Government Printing Office, 193 p. Gibson, J.J., Edwards, T.W.D., Bursey, G.G., and Prowse, T.D., 1993, Estimating evaporation using stable isotopes:
Florea, L.J., McGee, D.K., and Wynn, J.G., 2010, Stable Quantitative results and sensitivity analysis for two catch-isotopic and geochemical variability within shallow ments in northern Canada: Nordic Hydrology, no. 24, groundwater beneath a hardwood hammock and surface p. 79-94.
water in an adjoining slough (Everglades National Park, FL): Proceedings of the 14th Symposium on the Geology of Godfrey, M.C., 2006, River of interestsWater management the Bahamas and other Carbonate Regions, 15 p., accessed in south Florida and the Everglades, 1948-2000: U.S. Army October 31, 2012, at http://digitalcommons.wku.edu/geog_ Corps of Engineers, 460 p.
fac_pub/14.
Goldman, M., Gilad, D., Ronen, A., and Melloul, A., 1991, Florida Department of Environmental Protection, 2001, Mapping seawater intrusion into the coastal aquifer of Southeast district assessment and monitoring program, Israel by the time domain electromagnetic method: Geoex-ecosummary, Miami River, Miami-Dade County, accessed ploration, v. 28, p. 153-174.
January 31, 2011, at http://www.dep.state.fl.us/southeast/
Hagemeyer, Bart, 2012, ENSOs relation with Floridas ecosum/ecosums/Miami_River.pdf.
climate and predictabilityFlorida dry season forecast and Florida Department of Health, 2005, Chemicals in private El Nino-Southern Oscillation (EÑSO): National Aeronau-drinking water wellsFact sheetSodium: Florida Depart- tical and Atmospheric Administration, National Weather ment of Health, 2 p. Service Forecast Office, Melbourne Florida, accessed January 23, 2012, at http://www.srh.noaa.gov/mlb/?n=enso_
Florida Division of Emergency Management, 2009, Miami- florida_climate_forecast.
Dade County 2 ft contour lines: Tallahassee, FL, Florida Division of Emergency Management, Shapefile, accessed Harvey, J.W., Krupa, S.L., Gefvert, Cynthia, Mooney, R.H.,
February 10, 2011, at http://www.floridadisaster.org/gis/ Choi, Jungyill, King, S.A., and Giddings, J.B., 2002, Inter-index.asp. actions between surface water and ground water and the effects of mercury transport in the north-central Everglades:
Fuller, M.L., 1904, Contributions to the hydrology of east- U.S. Geological Survey Water-Resources Investigations ern United States: U.S. Geological Survey Water-Supply Report 02-4050, 82 p.
Paper 102.
Heaton, T.H.E., 1981, Dissolved Gases: Some Applications Galli, Gianni, 1991, Mangrove-generated structures and depo- to Groundwater Research: Transactions of the Geological sitional model of the Fort Thompson Formation (Florida Society of South Africa, v. 84, p. 91-97.
Plateau): Facies, v. 25, p. 297-314.
Heaton, T.H.E., and Vogel, J.C., 1981, Excess air in ground-Garbarino, J.R., 1999, Methods of analysis by the U.S. water: Journal of Hydrology, v. 50, p. 201-216.
Geological Survey National Water Quality Laboratory Determination of dissolved arsenic, boron, lithium, sele- Herzberg, A., 1901, Die Wasserversorgung einiger Nord-nium, strontium, thallium, and vanadium using inductively seebader [The water supply on parts of the North Sea coast]:
coupled plasma-mass spectrometry: U.S. Geological Survey Munich, Jour. Gasbeleuchtung und Wasser versorgung, Open-File Report 99-093, 31 p. v. 44, p. 815-819, 842-844.
Selected References69 Hickey, T.D., Hine, H.C., Shinn, E.A., Kruse, S.E., and Poore, Katz, B.G., and Bullen, T.D., 1996, The combined use of R.Z., 2010, Pleistocene carbonate stratigraphy of south 87 Sr/86Sr and carbon and water isotopes to study the hydro-FloridaEvidence for high-frequency sea-level cyclicity: chemical interaction between groundwater and lakewater Journal of Coastal Research, v. 26, no. 4, p. 605-614. in mantled karst: Geochimica et Cosmochimica Acta, v. 60, no. 24, p. 5075-5087.
Hinkle, S.R., Shapiro, S.D., Plummer, L.N., Busenberg, Eurybiades, Widman, P.K., Casile, G.C., and Wayland, Kaufman, A.A., and Keller, G.V., 1983, Frequency and tran-J.E., 2010, Estimates of tracer-based piston-flow ages of sient sounding: Amsterdam, Elsevier, 685 p.
groundwater from selected sitesNational Water-Quality Assessment Program, 1992-2005: U.S. Geological Survey Keller, G.V., and Frischknecht, F.C., 1966, Electrical meth-Scientific Investigations Report 2010-5229, 90 p. ods in geophysical prospecting: International Series of Monographs in Electromagnetic Waves: Oxford, Pergamon Hittle, C.D., 1999, Delineation of saltwater intrusion in the sur- Press, 519 p.
ficial aquifer system in eastern Palm Beach, Martin, and St.
Lucie Counties, Florida, 1997-98: U.S. Geological Survey Kendall, C., and Coplen, T.B., 2001, Distribution of oxy-Water-Resources Investigations Report 99-4214, 1 sheet. gen-18 and deuterium in river waters across the United States: Hydrological Processes, v. 15, p. 1363-1393.
Hoffmeister, J.E., Stockman, K.W., and Multer, H.G., 1967, Miami limestone and its recent Bahamian counterpart: Geo- Klein, Howard, 1957, Salt-water encroachment in Dade logical Society of America Bulletin v. 78, p. 175-190. County, Florida: Florida Geological Survey Information Circular 9, 5 p.
Howard, K.W.F., and Lloyd, J.W., 1983, Major ion character-ization of coastal saline ground waters: Groundwater, v. 21, Klein, Howard, 1965, Probable effect of Canal 111 on salt-no. 4, p. 429-437. water encroachment, southern Dade County Florida: U.S.
Geological Survey Open-File Report 65-86, 26 p.
Howarth, R.J., and McArthur, J.M., 1997, Statistics for strontium isotope stratigraphy; a robust LOWESS fit to the Klein, Howard, and Hull, J.E., 1978, Biscayne Aquifer, marine Sr-isotope curve for 0 to 206 Ma with look-up table Southeast Florida: U.S. Geological Survey Water-Resources for derivation of numeric age: The Journal of Geology, Investigations Report 78-107, p. 22-27.
- v. 105, no. 4, p. 441-456.
Klein, Howard, and Ratzlaff, K.W., 1989, Changes in salt-Hoy, N.D., 1952, Two maps of Dade County, Florida, show- water intrusion in the Biscayne aquifer, Hialeah-Miami ing approximate position of the 1,000-ppm isochlor as of Springs area, Dade County, Florida: U.S. Geological Survey 1951 and approximate area of potential salt-water penetra- Water-Resources Investigations Report 87-4249, 1 sheet.
tion under 1945 conditions: U.S. Geological Survey Open-File Report 52-78. Klein, Howard, and Waller, B.G., 1985, Synopsis of salt-water intrusion in Dade County, Florida, through 1984:
Hoy, N.D., and others, 1951, Six cross sections and an index U.S. Geological Survey Water-Resources Investigations map of the Miami area, Florida, showing changes in the Report 85-4101, 1 sheet.
position of the salt front in the Biscayne aquifer from 1946 to 1950: U.S. Geological Survey Open-File Report 51-119. Kohout, F.A., 1964, The flow of fresh water and salt water in Hughes, J.D., Langevin, C.D., and Brakefield-Goswami, the Biscayne aquifer of the Miami area, Florida, in Cooper, Linzy, 2010, Effect of hypersaline cooling canals on aquifer H.H., Jr., Kohout, F.A., Henry, H.R., and Glover, R.E., Sea salinization: Hydrogeology Journal, v. 18, p. 25-38. water in coastal aquifers: U.S. Geological Survey Water-Supply Paper 1613-C, p. C12-C32.
Janzen, J.H., and Krupa, Steven, 2011, Water quality charac-terization of southern Miami-Dade County and nearby FPL Kohout, F.A., and Hoy, N.D., 1963, Some aspects of sampling Turkey Point Power Plant, Miami-Dade County, Florida: salty ground water in coastal aquifers: Ground Water, v. 1, South Florida Water Management District Technical Publi- no. 1, p. 28-32.
cation WS-31, 5 sections, 171 p., 6 appendixes.
Kohout, F.A., and Leach, S.D., 1964, Saltwater movement Jennings, W.S., 1909, Letter in annual report of Trustees of the caused by control-dam operation in the Snake Creek Canal, Internal Improvement Fund, State of Florida, p. 122. Miami, Florida: State of Florida, State Board of Conser-vation, Division of Geology, Florida Geological Survey, Jones, B.F., Vengosh, A., Rosenthal, E., and Yechieli, Y., 1999, Report of Investigations, no. 24, part IV, 49 p.
Geochemical Investigations, in Bear, Jacob, Cheng, A.H.D.,
Sorek, Shaul, Ouazar, Driss, and Herrera, Ismael, eds., Koszalka, E.J., 1995, Delineation of saltwater intrusion in the Seawater intrusion in coastal aquifersConcepts, methods, Biscayne aquifer, eastern Broward County Florida, 1990:
and practices: Dordrecht, Netherlands, Kluwer Academic U.S. Geological Survey Water-Resources Investigations Publishers, 625 p. Report 93-4164, 1 sheet.
70 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Lane, S.L., Flanagan, Sarah, and Wilde, F.D., 2003, Selection McNeill, J.D., 1990, Use of electromagnetic methods for of equipment for water sampling (ver. 2.0): U.S. Geologi- groundwater studies, in Ward, S.H., ed., Geotechnical and cal Survey Techniques of Water-Resources Investigations, environmental geophysics: Tulsa, Society of Exploration book 9, chap. A2, March 2003, accessed June 25, 2013, at Geophysicists, p. 191-218.
http://pubs.water.usgs.gov/twri9A2/.
McNeill, J.D., Bosnar, M., and Snelgrove, F.B., 1990, Reso-Leach, S.D., and Grantham, R.G., 1966, Salt-water study of the lution of an electromagnetic borehole conductivity logger Miami River and its tributaries, Dade County, Florida: Florida for geotechnical and ground water applications: Geonics Geological Survey Report of Investigations no. 45, 35 p. Technical Note TN-25, 28 p.
Leach, S.D., Klein, Howard, and Hampton, E.R., 1972, Meinzer, O.E., Wenzel, L.K., and others, 1940, Water levels Hydrologic effects of water control and management of and artesian pressure in observation wells in the United southeastern Florida: Florida Bureau of Geology, Report of States in 1939: U.S. Geological Survey Water-Supply Investigations no. 60, 115 p. Paper 886.
Lietz, A.C., 1999, Methodology for estimating nutrient loads Meyer, F.W., 1974, Availability of ground water for the U.S.
discharged from the east coast canals to Biscayne Bay, Navy well field near Florida City, Dade County, Florida:
Miami-Dade County, Florida: U.S. Geological Survey U.S. Geological Survey Open-File Report 74-1072, 50 p.
Water-Resources Investigations Report 99-4094, 36 p.
Miller, J.A., 1986, Hydrogeologic framework of the Floridan Lietz, A.C., Dixon, Joann, and Byrne, Michael, 2002, Average aquifer system in Florida and in parts of Georgia, South altitude of the water table (1990-99) and frequency analysis Carolina, and Alabama: U.S. Geological Survey Profes-of water levels (1974-99) in the Biscayne aquifer, Miami- sional Paper 1403-B, 91 p.
Dade County, Florida: U.S. Geological Survey Open-File Report 02-91, 7 sheets. Miller, J.A., 1990, Ground water atlas of the United States; Alabama, Segment 6; Alabama, Florida, Georgia, and South Ludin, A.I., Weppernig, Ralf, Bonisch, G., and Schlosser, Carolina: U.S. Geological Survey Hydrologic Investigations Peter, 1997, Mass spectrometric measurement of helium Atlas 730-G, 28 p.
isotopes and tritium in water samples: Lamont-Doherty Earth Observatory of Columbia University, Technical Mount Sopris Instrument Co., Inc., 2002, 2PIA-1000 Poly Report 98.6, accessed May 12, 2011, at http://www.ldeo. induction probe, 2EMA-1000 conductivity probe (2 columbia.edu/~etg/ms_ms/Ludin_et_al_MS_Paper.html. EMB-1000 and 2ECM-1000) EMP-2493 and EMP-4493:
Golden CO, Mount Sopris, 19 p.
Marella, R.L., 1993, Public-supply water use in Florida, 1990:
U.S. Geological Survey Open-File Report 93-134, 46 p. Munroe, R.M., and Gilpin, Vincent, 1930, The Commodores story, the early days on Biscayne Bay, reprinted, Historical Marella, R.L., 1999, Water withdrawals, use, discharge, and Association of Southern Florida, 1966, 384 p.
trends in Florida, 1995: U.S. Geological Survey Water-Resources Investigations Report 99-4002, 90 p. National Climatic Data Center, 2012, Normal daily mean temperature, degrees Fahrenheit: National Aeronautical Marella, R.L., 2004, Water withdrawals, use, discharge, and and Atmospheric Administration, National Climatic Data trends in Florida, 2000: U.S. Geological Survey Scientific Center, accessed January 23, 2012, at http://lwf.ncdc.noaa.
Investigations Report 2004-5151, 50 p.
gov/oa/climate/online/ccd/meantemp.html.
Marella, R.L., 2009, Water withdrawals, use, and trends in National Oceanic and Atmospheric Administration, 2012, Florida, 2005: U.S. Geological Survey Scientific Investiga-Sea levels online: National Oceanic and Atmospheric tions Report 2009-5125, p. 11.
Administration, accessed November 30, 2012, at http://
Matson, G.C., and Sanford, S., 1913, Geology and ground tidesandcurrents.noaa.gov/sltrends/sltrends.shtml.
waters of Florida: U.S. Geological Survey Water-Supply Northwest Dade County Freshwater Lake Belt Plan, 1997, Paper 319, 445 p.
Making a whole not just a hole: South Florida Water Man-McArthur, J.M., Howarth, R.J., and Shields, G.A., 2012, agement District, 30 p.
Strontium Isotope Geochronology in The Geologic Time Scale, Gradstein, F.M., Ogg, J.G., Schmitz, M.D., Ogg, Oki, D.S., and Presley T.K., 2008, Causes of borehole flow G.M., eds., Elsevier Amsterdam, 1040 p., 3 appendixes. and effects on vertical salinity profiles in coastal aqui-fers: Conference program and proceedings, Program and McNeill, J.D., 1986, Geonics EM39 borehole conductivity proceedings book, 20th Salt Water Intrusion Meeting, meter theory of operation: Geonics Limited, Technical Note June 23-27, 2008, p. 170-173, accessed June 14, 2013, at TN-20, 9 p., 1 addendum. http://conference.ifas.ufl.edu/swim/papers.pdf.
Selected References71 Oldenburg, D.W., and Li, Y., 2005, Inversion for applied Reese, R.S., and Cunningham, K.J., 2000, Hydrogeology geophysicsA tutorial, in Butler, D.K., ed., Near surface of the gray limestone aquifer in southern Florida: U.S.
geophysics, Part 1Concepts and fundamentals: Tulsa, Geological Survey Water-Resources Investigations Report Society of Exploration Geophysicists, p.89-150. 99-4213, 244 p.
Paige, J.C., 1986, Historic resource study for Everglades Reese, R.S., and Richardson, E., 2008, Synthesis of the hydro-National Park, U.S. Department of the Interior, National geologic framework of the Floridan aquifer system and Park Service: Department of Commerce, National Technical delineation of a major Avon Park permeable zone in central Information Service, PB87199097, p. 138-143. and southern Florida: U.S. Geological Survey Scientific Investigations Report 2007-5207, 60 p.
Parker, G.G., 1945, Salt water encroachment in southern Florida: Journal of the American Water Works Association, Reese, R.S., and Wacker, M.A., 2009, Hydrogeologic and
- v. 37, no. 6, p. 526-542. hydraulic characterization of the surficial aquifer system, and origin of high salinity groundwater, Palm Beach County Parker, G.G., and Cooke, C.W., 1944, Late Cenozoic geology Florida: U.S. Geological Survey Scientific Investigations of southern Florida, with a discussion of the groundwater:
Report 2009-5113, 42 p., 2 appendixes.
Florida Geological Survey, Geological Bulletin no. 27, 3 pls.
Renken, R.A., Cunningham, K.J., Shapiro, A.M., Harvey, Parker, G.G., Ferguson, G.E., Love, S.K., and others, 1955, R.W., Zygnerski, M.R., Metge, D.W., and Wacker, M.A.,
Water resources of southeastern Florida, with special refer-2009, Pathogen and chemical transport in the karst lime-ence to the geology and ground water of the Miami area:
stone of the Biscayne aquifer1. Revised conceptualiza-U.S. Geological Survey Water-Supply Paper 1255, 965 p.
tion of groundwater flow: Water Resources Research, v. 44, Parks, A.M., 1987, Miami memoirs, John SewellA new W08429, doi:10.1029/2007WR006058.
pictorial addition: Miami, Arva Parks & Co., 267 p.
Renken, R.A., Dixon, Joann, Koehmstedt, John, Ishman, Perkins, R.D., 1977, Depositional framework of Pleistocene Scott, Lietz, A.C., Marella, R.L., Telis, Pamela, Rodgers, rocks in south Florida, in Enos, Paul, and Perkins, R.D., Jeff, and Memberg, Steven, 2005a, Impact of anthropo-eds., Quaternary sedimentation in south Florida: Geological genic development on coastal ground-water hydrology in Society of America Memoir 147, p. 131-198. southeastern Florida, 1900-2000: U.S. Geological Survey Circular 1275, 77 p.
Plummer, L.N., Bhkle, J.K., and Busenberg, Eurybiades, 2003, Approaches for ground-water dating, in Lindsey, Renken, R.A., Shapiro, A.M., Cunningham, K.J., Harvey, B.D., Phillips, S.W., Donnelly, C.A., Speiran, G.K., Plum- R.W., Metge, D.W., Zygnerski, M.R., Osborn, C.L., Wacker, mer, L.N., Bhlke, J.K., Focazio, M.J., Burton, W.C., M.A., and Ryan, J.N., 2005b, Assessing the vulnerability of and Busenberg, Eurybiades, Residence times and nitrate a municipal well field to contamination in a karst aquifer:
transport in groundwater discharging to streams in the Environmental and Engineering Geoscience, v. 11, no. 4, Chesapeake Bay Watershed: U.S. Geological Survey Water- p. 341-354.
Resources Investigations Report 03-4035, p. 12-24.
Révész, Kinga, and Coplen, T.B., 2008a, Determination of the Prinos, S.T., 2005, Correlation analysis of a ground-water (2H/1H) of water: RSIL lab code 1574, chap. C1 of Révész, level monitoring network, Miami-Dade County, Florida: Kinga, and Coplen, T.B., eds., Methods of the Reston Stable U.S. Geological Survey Open-File Report 2004-1412. Isotope Laboratory: U.S. Geological Survey Techniques and (Also available at http://pubs.usgs.gov/of/2004/1412/ Methods 10-C1, 27 p.
index.html.)
Révész, Kinga, and Coplen, T.B., 2008b, Determination of Prinos, S.T., Lietz, A.C., and Irvin, R.B., 2002, Design of a real- the (180/160) of water: RSIL lab code 489, chap. C2 of time ground-water level monitoring network and portrayal of Révész, Kinga, and Coplen, T.B., eds., Methods of the hydrologic data in southern Florida: U.S. Geological Survey Reston Stable Isotope Laboratory: U.S. Geological Survey Water-Resources Investigation Report 01-4275, 108 p. Techniques and Methods, 10-C2, 28 p.
Raymer, L.L., Hunt, E.R., and Gardner, J.S., 1980, An Richter, B.C., and Kreitler, C.W., 1993, Geochemical tech-improved sonic transit time-to-porosity transform, paper P, niques for identifying sources of ground-water salinization:
in 21st Annual Logging Symposium Transactions: Society Boca Raton, FL, CRC Press, 258 p.
of Professional Well Log Analysts, 12 p.
Rupert, M.G., and Plummer, L.N., 2004, Ground-water flow Reese, R.S., 1994, Hydrogeology and the distribution and ori- direction, water quality, recharge sources, and age, Great gin of salinity in the Floridan aquifer system, southeastern Sand Dunes National Monument, south-central Colorado, Florida: U.S. Geological Survey Water-Resources Investiga- 2000-2001: U.S. Geological Survey Scientific Investiga-tions Report 94-4010, 56 p. tions Report 2004-5027, 28 p.
72 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Schlosser, Peter, Stute, Martin, Dorr, Helmut, Sonntag, Sonenshein, R.S., and Koszalka, E.J., 1996, Trends in Christian, and Munnich, K.O., 1988, Tritium/3He dating of water-table altitude (1984-1993) and saltwater intru-shallow groundwater: Earth and Planetary Science Letters, sion (1974-1993) in the Biscayne aquifer, Dade County,
- v. 89, p. 353-362. Florida: U.S. Geological Survey Open-File Report 95-705, 2 sheets.
Schlosser, Peter, Stute, Martin, Sonntag, Christian, and Mun-nich, K.O., 1989, Tritiogenic 3He in shallow groundwater: Southeastern Geological Society Ad Hoc Committee on Earth and Planetary Science Letters, v. 94, p. 245-256. Florida Hydrostratigraphic Unit Definition, 1986, Hydro-geological units of Florida: Florida Department of Natural Schmerge, D.L., 2001, Distribution and origin of salinity in Resources, Bureau of Geology, Special Publication 28, 9 p.
the surficial and intermediate aquifer systems, southwestern Florida: U.S. Geological Survey Water-Resources Investiga- South Florida Water Management District, 1985, Interim tions Report 2001-4159, 41 p. drought management report: South Florida Water Manage-ment District May 9, 1985, Update, 112 p.
Schroeder, M.C., and Klein, Howard, 1954, Geology of the western Everglades Area, southern Florida: Florida Geo- South Florida Water Management District, 2010, Water use logical Survey, Geologic Survey Circular 314, 26 p. permit no. re-issue 13-00017-W, non-assignable, South Schroeder, M.C., Klein, Howard, and Hoy, N.D., 1958, Bis- Water Management District, 31 p., 37 app., Exhibit 5A, cayne aquifer of Dade and Broward Counties, Florida: Florida accessed January 12, 2012, at http://www.miamidade.gov/
Geological Survey Report of Investigations no. 17, 56 p. wasd/wup.asp.
Shaler, N.S., 1890, The topography of Florida: Bulletin of the Stalker, J.C., McFarlane, Andrew, and Price, R.M., 2010, Museum of Comparative Zoology at Harvard College, v. 16, Geochemical investigation of the surface water and ground-no. 7, p. 139-156. water in the immediate vicinity of Florida Power and Light, Turkey Point Cooling Canals: Florida International Shalev, Eyal, Lazar, Ariel, Wollam, Stuart, Kington, University, 43 p.
Shushanna, Yechieli, Yoseph, and Gvirtzman, Haim, 2009, Biased monitoring of freshwater-salt water mixing zone in Stewart, M.A., Bhatt, T.N., Fennema, R.J., and Fitterman, coastal aquifers: Ground Water, v. 47, no. 1, p. 49-46. D.V., 2002, The road to flamingoAn evaluation of flow pattern alterations and salinity intrusion in the Lower Shapiro, A.M., Renken, R.A., Harvey, R.W., Zygnerski, Glades, Everglades National Park: U.S. Geological Survey M.R., and Metge, D.W., 2008, Pathogen and chemical Open-File Report 2002-59, 36 p.
transport in the karst limestone of the Biscayne aqui-fer2. Chemical retention from diffusion and slow Stoneman-Douglas, Marjory, 1947, The EvergladesRiver of advection: Water Resources Research, v. 44, W08430, grass: Sarasota, Florida, Pineapple Press, Inc., 50th Anni-doi:10.1029/2007WR006059. versary Edition, 1997, 455 p.
Shaw, T.J., Moore, W.S., Kloepfer, Jeremiah, and Sochaski, Swayze, L.J., 1980, Water-level contour and salt front map, M.A., 1998, The flux of barium to the coastal waters of the Hialeah-Miami Springs well field area, Dade County, southeastern USAThe importance of submarine ground- Florida, October 13, 1978: U.S. Geological Survey Open-water discharge: Geochimica et Cosmochimica Acta, v. 62, File Report 80-8, 1 sheet.
no. 18, p. 3047-3054.
Taylor, K.C., Hess, J.W., and Mazzela, Aldo, 1989, Field Sherwood, C.B., and Klein, Howard, 1963, Surface- and evaluation of slim-hole borehole induction tool: Groundwa-ground-water relation in a highly permeable environment: ter Monitoring & Remediation, v. 9, issue 1, p. 100-104.
Berkeley, International Association of Scientific Hydrology, publication no. 63, p. 454-463. The Weather Channel, 2013, Monthly and daily averages for Miami, Florida, accessed January 3, 2011, at http://
Sherwood, C.B., and Leach, S.D., 1962, Hydrologic studies www.weather.com/weather/wxclimatology/monthly/graph/
in the Snapper Creek Canal area, Dade County, Florida: USFL0316.
Florida Geological Survey, Report of Investigations no. 24, Part II, 32 p. Trimble, P.J., Marban, J.A., Molian, Medardo, and Scully, S.P.,
1990, Analysis of the 1989-1990 drought: South Florida Smith, R.S., 1909, The reclamation of the Florida Everglades, Water Management District Special Report DRE 286, 80 p.
Miami, Florida, p. 16b.
Turekian, K.K., 1976, Oceans (2d ed.): Prentice-Hall, 149 p.
Sonenshein, R.S., 1997, Delineation and extent of saltwater intrusion in the Biscayne aquifer, eastern Dade County, U.S. Census Bureau, 2010, State and county quick facts, Florida, 1995: U.S. Geological Survey Water-Resources Miami-Dade County, Florida, accessed September 9, 2011, Investigations Report 96-4285, 1 sheet. at http://quickfacts.census.gov/qfd/states/12/12086.html.
Selected References73 U.S. Census Bureau, 2013, Population estimates, counties, U.S. Geological Survey, 2011f, National Water Information accessed March 15, 2013, at http://www.census.gov/popest/ SystemWeb interfaceWater Data for the Nation: U.S.
data/historical/index.html. Geological Survey, accessed October 5, 2011, at http://nwis.
waterdata.usgs.gov/usa/nwis/.
U.S. Congress, 1850, Index to Executive Documents printed by order of the United States during the first session of the thirty- U.S. Geological Survey, 2011g, Saline intrusion monitoring, first congress 1849-50, Washington: Wm. M. Belt, 98 p. Miami-Dade County, Florida: U.S. Geological Survey, accessed October 10, 2011, at http://www.envirobase.usgs.
U.S. Environmental Protection Agency, 2000, SF6 Emis- gov/FLIMS/.
sions reduction partnership for electronic power systems, annual report, 2000: U.S. Environmental Protection Agency, U.S. Geological Survey, 2011h, Groundwater conditions 9 p., accessed May 17, 2001, at http://www.epa.gov/ in southern Florida: U.S. Geological Survey, accessed electricpower-sf6/documents/sf6_emiss_rep.pdf. October 5, 2011, at http://www.sflorida.er.usgs.gov/edl_
data/index_ndt.html.
U.S. Environmental Protection Agency, 2011a, Second-ary drinking water regulations; guidance for nuisance U.S. Geological Survey, 2011i, Reston Chlorofluorocarbon chemicals: U.S. Environmental Protection Agency LaboratoryAnalytical procedures for dissolved gasses Report 816-f-10-079, accessed January 26, 2011, at http:// N2 / Ar: U.S. Geological Survey, accessed April 26, 2011, water.epa.gov/drink/contaminants/secondarystandards.cfm. at http://water.usgs.gov/lab/dissolved-gas/lab/analytical_
procedures/.
U.S. Environmental Protection Agency, 2011b, Drinking water contaminantsNational primary drinking water standards, Van Wagoner, J.C., 1985, Reservoir facies distribution as accessed February 23, 2011, at http://water.epa.gov/drink/ controlled by sea-level change: Abstract and Poster Session, contaminants/index.cfm. Society of Economic Paleontologists and Mineralogists Mid-Year Meeting, Golden, Colorado, p. 91-92.
U.S. Geological Survey, variously dated, National field manual for the collection of water-quality data: U.S. Geo- Vengosh, Avner, and Pankratov, Irena, 1998, Chloride/bromide logical Survey Techniques of Water-Resources Investiga- and chloride/fluoride ratios of domestic sewage effluents tions, book 9, chaps. A1-A9, available online at http://pubs. and associated contaminated ground water: Ground Water, water.usgs.gov/twri9A. v. 36, no. 5, p. 815-824.
U.S. Geological Survey, 2011a, Reston Chlorofluorocar- Verdi, R.J., Tomlinson, S.A., and Marella, R.L., 2006, The bon LaboratorySF6 sampling: U.S. Geological Survey, drought of 1998-2002Impacts on Floridas Hydrology and accessed April 29, 2011, at http://water.usgs.gov/lab/sf6/ Landscape: U.S. Geological Survey Circular 1295, 34 p.
sampling/.
Wacker, M.A., 2010, Tools and data acquisition of borehole U.S. Geological Survey, 2011b, Reston Chlorofluorocarbon geophysical logging for the Florida Power and Lights Com-LaboratoryDissolved Gas N2 / Ar and 4He Sampling: pany Turkey Point Power Plant in support of a groundwater, U.S. Geological Survey, accessed June 25, 2013, at http:// surface-water, and ecological monitoring plan, Miami-water.usgs.gov/lab/dissolved-gas/sampling/. Dade County, Florida: U.S. Geological Survey Open-File Report 2010-1260, 5 p., appendixes.
U.S. Geological Survey, 2011c, Reston Chlorofluorocarbon Laboratory3H/3He sampling: U.S. Geological Survey, Wacker, M.A., and Cunningham, K.J., 2008, Borehole geo-accessed April 26, 2011, at http://water.usgs.gov/lab/3h3he/ physical logging programIncorporating new and existing sampling/. techniques in hydrologic studies: U.S. Geological Survey Fact Sheet 2008-3098, 4 p.
U.S. Geological Survey, 2011d, Reston Chlorofluorocarbon LaboratoryAnalytical procedures for SF6: U.S. Geologi- Waller, B.G., 1985, Drought of 1980-82 in southeast Florida cal Survey, accessed April 26, 2011, at http://water.usgs. with comparison to the 1961-62 and 1970-71 droughts:
gov/lab/sf6/lab/analytical_procedures/. U.S. Geological Survey Water-Resources Investigations Report 85-4152, p. 24-28.
U.S. Geological Survey, 2011e, Annual Water Data Reports:
U.S. Geological Survey, accessed June 18, 2013, at Wright, J.O., 1912, The Everglades of FloridaTheir adapt-http://wdr.water.usgs.gov/. ability for the growth of sugar cane: Tallahassee, FL, 81 p.
Appendixes 1-12 76 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Appendix 1. Site Location and Appendix 3. Salinity Profiles Construction Information Collected from the Card Sound Road Appendix 1 provides site location and construction Canal information for sites used to evaluate the inland extent Salinity profiles were collected in the Card Sound Road of saltwater or the causes of saltwater intrusion in the Canal to evaluate the extent to which saltwater can flow inland Biscayne aquifer. Monitoring results from these sites are along this canal (appendix 3). The latitude and longitude of available from the USGS Annual Water Data Reports and each site are provided in a decimal degree format that has been National Water Information SystemWeb interfaceWater adjusted to the NAD83 datum. This can be used to import this quality samples for the Nation websites (U.S. Geological file into a GIS.
Survey, 2011a, b) or from the organizations listed in this See supplemental file http://pubs.usgs.gov/sir/2014/5025/
appendix. This information is provided in a supplementary appendix/sir2014-5025_appendix_03.xlsx.
Microsoft ExcelTM file. The latitude and longitude of each site are provided in a decimal degree format that has been adjusted to the NAD83 datum. This can be used to import this file into a GIS. Appendix 4. Results of Time-Domain See supplemental file http://pubs.usgs.gov/
Electromagnetic Soundings sir/2014/5025/appendix/sir2014-5025_appendix_01.xlsx. Appendix 4 provides a summary of information concerning 79 TEM soundings that were made during 2008 and 2009. This summary is provided in a supplementary Microsoft ExcelTM file. Soundings MIA101-MIA137 were References collected between April 28, 2008, and May 8, 2008. Soundings MIA201-MIA242 were collected between February 23, 2009, U.S. Geological Survey, 2011a, Annual Water Data Reports: and March 9, 2009. The 2008 field season focused on gathering U.S. Geological Survey, accessed June 18, 2013, at information from the Broward County line south to Florida http://wdr.water.usgs.gov/. City in southern Miami-Dade County to fill gaps in the spatial coverage of existing monitoring wells and to determine if the U.S. Geological Survey, 2011b, National Water Information extent of saltwater encroachment had changed since the work SystemWeb interfaceWater Data for the Nation: U.S. of Sonenshein (1997). The 2009 field season was focused Geological Survey, accessed October 5, 2011, at primarily in southeast Miami-Dade County in the Model Land, http://nwis.waterdata.usgs.gov/usa/nwis/. but also includes a number of soundings in southern Broward County, which helped to establish the location of the saltwater front in northern Miami-Dade County. The soundings collected in the Model Land were located to help interpret the HEM Appendix 2. Results of Geochemical survey flown in 2001 to map saltwater encroachment. The locations of the TEM soundings were determined by global Sampling positioning system (GPS) measurements. Horizontal coordi-nates are in UTM Zone 17R, in meters, referenced to NAD 83.
Appendix 2 provides the results of 69 geochemical Positioning errors are 4 to 5 m. Detailed information concerning samples and 3 replicate samples from 44 sites. This these measurements is provided in Fitterman and Prinos (2011).
information is available in 7 supplementary Microsoft See supplemental file http://pubs.usgs.gov/sir/2014/5025/
ExcelTM files. appendix/sir2014-5025_appendix_04.xlsx.
See supplemental files:
Appendix_02_Table1.xlsx References Appendix_02_Table2.xlsx Appendix_02_Table3.xlsx Fitterman, D.V., and Prinos, S.T., 2011, Results of time-Appendix_02_Table4.xlsx domain electromagnetic soundings in Miami-Dade and Appendix_02_Table5.xlsx southern Broward Counties, Florida: U.S. Geological Sur-Appendix_02_Table6.xlsx vey Open-File Report 2011-1299, 289 p.
Appendix_02_Table7.xlsx Sonenshein, R.S., 1997, Delineation and extent of saltwater intrusion in the Biscayne aquifer, eastern Dade County, available at http://pubs.usgs.gov/sir/2014/5025/appendix/ Florida, 1995: U.S. Geological Survey Water-Resources sir2014-5025_appendix_02. Investigations Report 96-4285, 1 sheet.
Appendixes77 Appendix 5. Time-Series the probe near an area with the potential for electromagnetic interference. When there is a significant difference between Electromagnetic Induction Log the temperature of the induction probe and the temperature of water in the borehole, there can be a shift in the observed log (TSEMIL) Dataset Calibration and (Mount Sopris Instrument Co., Inc., 2002, p. 15), so prior to Processing calibration, the probe is allowed to equilibrate with the water in the well at a depth of about 6 m until the readings stabilize.
The following is a synopsis of induction log calibration Once readings are stable, the probe is removed from the well, procedures and TSEMIL dataset processing. and the calibration is performed as quickly as possible to reduce temperature-induced variations. Following calibration, the probe is returned to the well at a depth of about 6 m and Calibration Procedures is again allowed to equilibrate with the water in the well until readings are constant. Once readings have stabilized, the probe Prior to the collection of individual induction logs, is raised until a selected reference point on the probe aligns factory-prescribed procedures (Mount Sopris Instrument Co.,
with a reference point near the top of the well. The down-hole Inc., 2002, p. 7-11, 15) that adhere to ASTM International log is then collected. Logs are generally collected in both guidelines (ASTM International, 2007) are used to calibrate a down-hole and an up-hole direction. These two logs are the logging probe. Given the variety of equipment used compared to evaluate the quality of each log. In tight wells, through time, differences in temperature and humidity during the probe may become temporarily stuck in the well even as calibrations, and variations in instrument sensitivity and drift, additional cable is played out by the winch. This can cause a the only actual constants existing in the calibration process are temporary discontinuity between the actual depth of the probe the calibration coils themselves. Each calibration performed and the depth recorded by the winch. To ensure data quality, is an attempt to align the data with these constants. The probe therefore, the up-hole log is generally used because this allows readings in counts per second (cps) are converted to values of the maximum amount of time for the probe temperature to bulk conductivity by using the equation of a straight line that achieve equilibrium with the water in the borehole and because is determined by a two-point calibration process. Calibration the cable connected to the probe is under constant tension, is accomplished by using a factory-manufactured calibration which reduces the potential for inaccurate depth measurements.
coil. The coil is designed to provide known bulk conductivity The induction logging systems and software used for values that can be selected by using a switch on the coil. collection of the logs presented in this report have changed Available settings are 0, 91, 460, and 1,704 mS/m. The settings a number of times during the 17 years that data have been selected depend on the desired range, which can be 0 to 100, collected. Between 1995 and 1997, the equipment used was a 0 to 1,000, or 0 to 10,000 mS/m. During the calibration Mount Sopris Instrument Co., Inc. MGX portable logging unit process, a coil setting of zero is selected for the first calibration operated using Logshell' software, an MGB-1000 ultralight point. The second calibration point is obtained by selecting the winch, and an EMA-1000 induction probe. The EMA-1000 coil setting that is most appropriate for the selected range. The induction probe is based on the Geonics EM39 induction range used for this effort was 0 to 1,000 mS/m because many probe. In 1998, the MGX portable logger was upgraded by of the wells used already yielded saltwater. installing a digital MGXII console using Logshell' software.
Several different calibration settings and methods were Beginning in 2000, the Logshell' software was upgraded used during this effort. An older calibration coil used for this to MSLog' software. The Logshell' software was used study had settings of 0, 81, 345, and 1,301 mS/m. This coil again for the logs collected in 2001 because of the trunca-was used to calibrate the logs collected from 1996 to 2007. tion of some of the values recorded in the output files. The This coil is discussed in greater detail in subsequent sections EMA-1000 induction probe malfunctioned in 2002, and the of this appendix. The logs collected in 1995 were calibrated logs collected that year were obtained by using an induction by using an alternate procedure described by Mount Sopris probe borrowed from the USGS Tennessee Water Science Instrument Co., Inc., (2002, p. 7) that uses free air for the zero Center. A new induction probe was purchased and used from setting and a value for the second calibration point that consists 2003 to 2006. The truncation issues related to the software had of the frequency of pulses from the tool at the zero point been addressed by 2002, and instrumentation was operated plus 5,000. Most of the logs collected during 1996 to 2001, using MSLog' software during 2002 to 2006. In 2007, after excluding 1998, were calibrated by using a setting of 1,301 on another probe malfunction, an EM39 induction probe was the calibration coil for the second calibration point. Most of the rented from Colog Borehole Geophysical Services for the logs collected in 1998 and during 2002 to 2007 were calibrated collection of logs that year. Currently (2013), a 2PIA-1000 by using the 345-mS/m setting for the second point. All of the EM39 induction probe, a 4305-1000-120 mini winch, and a logs collected since 2008 have been calibrated by using the 5MXA-1000-120 Matrix' logging console operated using newer coil and a setting of 460 for the second point. Matrix' logging software are being used.
During calibration, metal objects also are kept as far Although there have been a number of modifications from the probe as possible. Care is taken to avoid calibrating to the probes that have been used through time, all of the
78 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater probes used were based on the EM39 design. The EM39 and measurement process rather than by actual changes in probe provides a radius of maximum sensitivity of 28 cm, a aquifer water quality because these offsets are almost perfectly radius of minimum sensitivity of 10 cm, and vertical resolu- uniform throughout the thickness of freshwater parts of the tion of 65 cm (McNeill, 1986; Mount Sopris Instrument Co., aquifer. The offsets could be caused by slight differences in Inc., 2002, p. 17). This means that the probe is insensitive calibration resulting from variations in temperature, humidity, to changes in borehole fluid in wells with a diameter of less and calibration time, because the probe must be removed than 20 cm. Most of the wells logged during this study had a from the well for calibration. Even though the offsets are diameter of 5 cm, and changes in the electrical conductivity of small (+/-7 mS/m), they obscure the ability to identify small the fluid in these boreholes should not have affected the logs. but real changes in bulk conductivity that occurred as changes The probe provides appreciable sensitivity out to a radius of in the salinity of the pore water occurred. A technique was 100 cm (McNeill and others, 1990, p. 5). Measurement resolu- developed, therefore, to remove the offsets to create TSEMIL tion and accuracy are 0.02 and 5 percent of full scale, respec- datasets that could be used to more clearly identify changes in tively (Mount Sopris Instrument Co., Inc., 2002, p. 17). Given bulk conductivity resulting from saltwater intrusion.
the full scale of 1,000 mS/m, the accuracy is about 50 mS/m. The offsets apparent in the time series of EMI logs The data collected in the study area by the USGS during the (fig. 5-1) are removed on a log-by-log basis. An important last 17 years, using various versions of the EM39 induction consideration of this procedure is that if there are no actual probe and varying calibration methods, and coils, however, changes in the electrical conductivity of water occurring indicate that much greater accuracy may be possible. Although through time in the aquifer, then the adjustments made to there were some issues with calibration slope and offset, once the time series of EMI logs should not alter the mean bulk they were addressed, the data collected where salinity is not conductivity of the set of EMI logs. In other words, with changing tended to agree to within +/- 1.0 to 1.5 mS/m even few exceptions, the corrected set of EMI logs should not be though changes have been made to the hardware and software skewed to the left or right of the mean of the uncorrected set used to collect these logs. of logs. The offsets between individual EMI logs were nearly constant throughout the freshwater-saturated interval; aligning individual logs to the left or right of the mean bulk conduc-Corrections of Calibration Slope tivity measured at one depth generally created near perfect alignment at all depths in the freshwater-saturated interval.
A two-point calibration process is used to determine The correction process consisted, therefore, of (1) determining the equation of a straight line that is used by the operating the mean bulk conductivity measured by the full time series of software to convert probe readings (cps) to bulk conductivity.
EMI logs at a selected depth within the freshwater-saturated The equation of this line includes a slope and offset. Rela-interval, (2) determining the difference between this value tively large errors in the calibration slope of logs were caused and the bulk conductivity measured at this same depth for during 1996 to 2007 by using a calibration coil that had been an individual log of the set, (3) subtracting this difference marked at the factory with incorrect values and during 1996 to from each bulk conductivity measurement of that log, and 2001 (excluding 1998) by using a second calibration point that (4) repeating this process for all logs in the set until they was greater than the full-scale reading of 1,000 mS/m. The were all aligned to the mean bulk conductivity at the selected calibration coil error was discovered in 2008 when logs were depth. This process creates near perfect alignment of the set of collected using a new calibration coil from the same factory.
EMI logs and creates the ability to identify small differences Both coils were sent back to the factory for examination.
between logs that were otherwise obscured by the offsets that This examination revealed that the coil settings labeled 81, had been present (fig. 5-2).
345, and 1,301 mS/m should have been labeled 91, 460, and The first EMI log of the TSEMIL dataset from well 1,700 mS/m, respectively, and that given the incorrect labels, G-3611 collected on January 9, 1996, shows slightly elevated the calibrations applied during 1996 to 2007 were generally bulk conductivity at depths of 6.7 and 16.7 m (fig. 5-2). This off by about 11 to 25 percent. After the necessary corrections change in bulk conductivity is a common observation in many had been applied to the slope of the affected logs, only minor of the TSEMIL datasets from new wells. It likely results from
+/-7 mS/m offsets remained between any of logs.
water of greater than normal electrical conductivity entering porous rock layers during the drilling process. Generally, the TSEMIL Dataset Processing electrically conductive water dissipates during the first few years of logging the well.
Where a time series of EMI logs was collected from a A simple method to ensure that the corrections were well penetrating freshwater parts of the Biscayne aquifer, the applied correctly is to verify that the sum of all corrections individual EMI logs of the set are nearly identical, with the applied is zero. By using the corrections that were applied to exception of small and uniform offsets in bulk conductivity align individual logs to the mean of all logs at a given depth, between the logs collected on different dates (fig. 5-1). the standard deviation of a TSEMIL dataset may also be These offsets are generally within +/-7 mS/m of the mean of determined. Simple graphical examinations of the time series the log set. The offsets are likely caused by the calibration of the logs prior to and following these corrections allow the
Appendixes79 0
EXPLANATION G-3611 electromagnetic induction logs 1/9/1996 5/8/1996 5
4/22/1997 4/1998 4/8/1999 4/18/2000 4/5/2001 10 5/17/2002 5/1/2003 Depth, in meters below land surface 4/26/2004 4/26/2005 4/20/2006 6/13/2007 15 4/30/2008 5/06/2009 4/9/2010 4/7/2011 Logs differ from each other over a range of approximately 14 millisiemens per meter. Given these differences, it is 20 difficult to determine if any real changes may be occurring 25 Screened 30 29.0 to 30.5 meters 0 10 20 30 40 50 Bulk conductivity, in millisiemens per meter Figure 5-1. Electromagnetic induction logs collected from monitoring well G-3611 from January 1996 to April 2011 prior to bulk conductivity adjustments, Miami-Dade County, Florida.
evaluation of the best overall alignment for a given dataset. the result of random instrumentation noise, but is slightly Multiple depths may be selected to computationally determine greater than the manufacturer-specified noise level of less than the best overall alignment, and the adjustments computed 0.5 mS/m (Mount Sopris Instrument Co., Inc., 2002); equip-for each individual log can be averaged. Logs could also be ment variation, drift, and calibration may have been contrib-aligned to the median bulk conductivity measured at selected uting factors. This random variation is much smaller than depths if desired. Depending on the goals of the research and the difference in change in bulk resistivity occurring when aquifer conditions, this method could also be used to establish saltwater enters previously freshwater-saturated materials.
a baseline to which all future logs would be corrected. Caution should be used when interpreting the resulting When using the correction procedures described, there TSEMIL datasets because apparent changes in bulk conduc-generally remains only about +/-1 to 1.5 mS/m of completely tivity are much smaller than the manufacturer-specified irregular variation between successive logs that cannot be precision of the equipment. One way to evaluate the quality removed (fig. 5-2). Even if perfect numerical alignment is of corrections applied to the time series of EMI logs is to achieved at one or two depths, the +/-1 to 1.5 mS/m of random compare the evident changes in bulk conductivity in the variation remains at all other depths. This variation is likely TSEMIL dataset to chloride concentrations in samples
80 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 0
EXPLANATION Variations in bulk conductivity near the land surface are observed in most log sets; these variations could G-3611 electromagnetic be caused by variations in water temperature or induction logs saturation of pore spaces near the land surface 1/9/1996 5/8/1996 5
4/22/1997 4/1998 4/8/1999 4/18/2000 These depth intervals may have 4/5/2001 become intruded with conductive 10 5/17/2002 water when the well was drilled.
The conductive water appears to 5/1/2003 Depth, in meters below land surface be slowly dissipating 4/26/2004 4/26/2005 4/20/2006 6/13/2007 15 4/30/2008 5/06/2009 4/9/2010 4/7/2011 20 With a few exceptions, the bulk conductivity of all logs agree within approximately 2 to 3 millisiemens per meter 25 Screened 30 29.0 to 30.5 meters 0 10 20 30 40 50 Bulk conductivity, in millisiemens per meter Figure 5-2. Time series electromagnetic induction log dataset that results from correction of errors in the calibration slope and offset. Monitoring well G-3611, January 1996 to April 2011, Miami-Dade County, Florida.
collected from the screen interval of the well. The chloride Considering the magnitude of corrections that have concentrations in samples collected from well G-3611 were been applied and all of the other factors that could potentially compared to the bulk conductivity measured at a depth of lead to differences between logs, the correlations observed 29.4 m (fig. 5-3). The chloride measurements and EMI logs between chloride and bulk conductivity (fig. 5-3) indicate collected during January and May 1996 have been excluded that the application of this method to the time series of EMI from the graph, because they were collected on different data produces reasonable results. Factors that could lead to dates. During 1997 to 2000, changes in chloride concentration differences include (1) a manufacturer-specified measure-were not reflected in the EMI logs, but the 15-mg/L increase ment accuracy of 5 percent of full scale, or 50 mS/m for in chloride concentration that occurred between 2001 and a full scale setting of 1,000 mS/m, (2) the relatively small 2002 corresponds to a 2-mS/m increase in bulk conductivity. changes in the chloride concentration in water samples, (3) the The gradual decrease in chloride concentration from 200 to magnitude of corrections applied to bulk conductivity that 170 mg/L that occurred between 2002 and 2011 corresponds are larger than the final range in bulk conductivity data at the to a gradual 4-mS/m decrease in bulk conductivity. depth 29.4 m, (4) the difference in EMI-log measured depth
Appendixes81 325 40 300 275 250 30 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 225 200 175 20 150 125 100 10 75 50 EXPLANATION Chloride concentration 25 Bulk conductivity 0 0 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 5-3. Chloride concentrations in water samples collected from well G-3611 and the corrected bulk conductivity measured at a depth of 29.4 meters, Miami-Dade County, Florida.
and the depth of the screened interval, caused by the probe open interval of this well, which is 24.4 to 25.9 m (fig. 42B).
encountering the bottom of the well before a full response Similar comparisons of chloride concentration sampled and can be measured from the open interval and recorded, (5) the bulk conductivity measured are provided for most of the number of different EMI logging instruments and calibration TSEMI datasets published in this report (figs. 32B, 33B, 35B, methods that have been used, (6) the potential for chloride 38B, 41B, 43B, 44B, and 45B). In general, the changes in bulk concentration in water samples to change rapidly if drawn conductivity measured and chloride concentration samples are from well-connected pore spaces, while EMI logs would also similar. The depth intervals from which bulk conductivity data measure water trapped in finer pores that diffuses more slowly, were compiled for comparisons were often a little shallower and (7) the potential for water to be drawn in from outside the than the top of the screened interval, where chloride samples radius of investigation of the EMI logging equipment during were collected. This decision was made because the EMI water sampling. All of these factors could create large differ- probe typically encounters the bottom of the well before a full ences between the chloride concentration in water samples and response to aquifer materials can be recorded at the screened measured bulk conductivity. Yet some of the changes in bulk interval. The new well design (appendix 7) should allow better conductivity do correspond to changes in the chloride concen- comparisons of bulk conductivity measurements and chloride tration in water samples (fig. 5-3), and this correspondence is concentrations sampled from the screened interval because the not unique to this site. probe will be able to be lowered past the bottom of the screen The TSEMIL dataset from well G-3609 provides an and will be able to record a full response to aquifer materials example of the potential precision of this method. Prior to within the screened interval.
adjustment, the individual EMI logs were difficult to interpret The TSEMIL datasets collected in the study area (fig. 5-4). Once these logs were processed using the methods frequently indicate changes in bulk conductivity through time, described, however, the temporal changes in bulk conductivity from near the land surface to a depth of about 10 m. These in the depth interval 19 to 23 m became immediately evident changes may be caused by (1) differences in water temperature (fig. 42A). The changes in bulk conductivity occurring over time at shallow depths, (2) differences in the saturation in this depth interval generally agree with the changes in of pore spaces near the water table, and (3) the influence chloride concentration in water samples collected from the of saline and conductive purge water that may have soaked
82 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 0
EXPLANATION G-3609 2 electromagnetic induction logs 1/17/1996 5/24/1996 4
4/23/1997 4/1998 4/9/1999 6
4/13/2000 4/06/2001 5/20/2002 8 4/30/2003 4/23/2004 Depth, in meters below land surface 4/27/2005 10 4/24/2006 6/14/2007 4/30/2008 12 5/06/2009 4/13/2010 4/21/2011 14 16 18 20 22 Screened 24.4 to 25.9 meters 24 0 10 20 30 40 50 60 70 80 Bulk conductivity, in millisiemens per meter Figure 5-4. Electromagnetic induction logs collected from monitoring well G-3609 from January 1996 to April 2011, Miami-Dade County, Florida.
into the ground near the well. Frequently, where the chloride generally addresses only the offsets between logs. With the concentrations in water samples from the well are increasing, exception of the calibration coil error, it appears that the most the bulk conductivity of the shallow layers is also increasing. of the differences between individual logs can be addressed by Examination of TSEMIL datasets reveals that the removing the apparent offsets between individual logs. Any thickness of the saltwater interface in the Biscayne aquifer apparent temporal changes that could be a function of calibra-varies. The TSEMIL dataset collected in well G-3604 tion slope should be considered when using TSEMIL datasets (fig. 41A) shows a 1.7-m-thick transition between freshwater to evaluate possible temporal changes in aquifer salinity and water with a chloride concentration of 5,000 mg/L. The because the slope corrections generally are not considered TSEMIL dataset collected in well G-3699 (fig. 44A) indicates during the adjustment process. Slope differences frequently that the transition between freshwater and water with a can be ruled out as a significant factor when differences in chloride concentration of 9,700 mg/L is 6.2 m thick. aquifer salinity apparent in TSEMIL datasets and occurring Although both slope and offset are components of the below the saltwater interface are compared with the parts of calibration equation, the procedure described previously the TSEMIL datasets that are above the saltwater interface.
Appendixes83 References
- Type 2 - Model does not indicate a layer of saltwater occurring within the Biscayne aquifer (fig. 6-2), but model does indicate a decrease in resistivity that occurs ASTM International, 2007, Standard guide for conducting at or near to the depth of the base of the Biscayne aquifer.
borehole geophysical loggingelectromagnetic induction:
ASTM International D 6726-01 (reapproved 2007), 8 p.
- Type 3 - Model does not indicate any layer that is likely associated with the base of the Biscayne aquifer McNeill, J.D., 1986, Geonics EM39 borehole conductivity (fig. 6-3). Measurement indicates freshwater (resistiv-meter theory of operation: Geonics Limited, Technical Note ity > 15 ohm-m) throughout the depth modeled, and TN-20, 9 p., 1 addendum. modeled depth extends at least as deep as the base of the Biscayne aquifer.
McNeill, J.D., Bosnar, M., and Snelgrove, F.B., 1990, Reso-lution of an electromagnetic borehole conductivity logger
- Type 4 - Model does not indicate any layer likely to be for geotechnical and ground water applications: Geonics associated with the base of the Biscayne aquifer, but Technical Note TN-25, 28 p. a relatively conductive layer (resistivity < 15 ohm-m) occurs well below the base of the Biscayne aqui-Mount Sopris Instrument Co., Inc., 2002, 2PIA-1000 Poly fer. The top of this deeper conductive layer in some induction probe, 2EMA-1000 conductivity probe (2 instances corresponds to the base of the surficial EMB-1000 and 2ECM-1000) EMP-2493 and EMP-4493: aquifer (fig. 6-4).
Golden CO, Mount Sopris, 19 p.
There are also a few subtypes that can be described.
These are
- Subtype 1a models are similar to type 1 models in that Appendix 6. Evaluation of Depth of a conductive layer (resistivity < 15 ohm-m) occurs within the Biscayne aquifer; however, the thickness the Biscayne Aquifer by Using TEM of the conductive layer could not be determined, and Soundings its potential relation with the depth of the base of the Biscayne aquifer could not be evaluated.
Understanding the depth of the base of the Biscayne
- Subtype 1b models have a conductive layer (resistivity aquifer is important for creating maps of saltwater intrusion < 15 ohm-m) occurring within the Biscayne aqui-because saltwater may encroach along the base. At the outset fer, but the thickness of this layer extends below the of the current study, existing contour maps of the base of estimated depth of the Biscayne aquifer and into the the Biscayne aquifer were available for Broward County semiconfining unit of the surficial aquifer system.
(Fish, 1988) and Miami-Dade County (Fish and Stewart, 1991).
The TEM results from the current study were evaluated to deter-
- Subtype 3a models consist of a resistive layer or layers mine the extent of agreement between the depths of selected (resistivity > 15 ohm-m) within the Biscayne aquifer model layers and the depth of the Biscayne aquifer mapped by that may not fully penetrate the aquifer. It cannot be Fish (1988) and Fish and Stewart (1991) (appendix 4). ascertained whether resistive water extends fully to Wherever possible, the depth to the bases of the Biscayne the base of the Biscayne aquifer or beyond because the aquifer mapped by Fish (1988) or Fish and Stewart (1991) was thickness of the deepest resistive layer of these models interpolated at each TEM location and compared to the depths could not be determined.
of selected model layers of TEM soundings. The values of Appendix 4 provides (1) the resistivity of model layers, altitude below sea level provided by Fish and Stewart (1991) (2) the depths of the model layers, (3) the estimated depth of were converted to depth by using the altitude of the land the base of the Biscayne aquifer at each measurement location surface at each TEM sounding location interpolated from the from Fish and Stewart (1991) or Fish (1988), (4) the model data provided by a recent light detection and ranging (LIDAR) type or subtype, and (5) the difference between the depth of the study (Florida Division of Emergency Management, 2009). base of the Biscayne aquifer modeled from the TEM sounding, The contour intervals of Fish and Stewart (1991) and the if evident, and that estimated from Fish and Stewart (1991).
Although these relations are subject to interpretation 2008 LIDAR study were 3.0 and 0.6 m, respectively. The rela-because they rely on previously mapped aquifer depths, this tions between modeled depths and aquifer depths interpolated information may be used to assist geologic mapping efforts.
from the contours of Fish (1988) or Fish and Stewart (1991)
Appendix 4 provides a summary of the types of relations fall into four general categories: between the estimated depth of the base of Biscayne aquifer
- Type 1 - Model indicates a layer of saltwater and the depth of selected model layers. Where such compari-(resistivity 15 ohm-m) occurring within the Biscayne sons are possible, table 6-1 provides the minimum, maximum, aquifer (fig. 6-1). The bottom of this model layer and average differences between the estimated depth of the appears to correspond closely with the depth of the base of the Biscayne aquifer and the depth of the selected base of the Biscayne aquifer. model layers.
84 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A. MIA231 B. MIA231 1,000 0 Estimated depth of base of Biscayne aquifer 100 50 Apparent resistivity, in ohm-meters Depth, in meters 10 100 1 150 0.001 0.01 0.1 1 10 1 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of high frequency saltwater saturated materials data Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data and error Resistivities > 15 ohm-m indicate marker freshwater saturated materials High frequency data and error Model fit of ultra high frequency marker data Figure 6-1. Type 1 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
Of the 79 TEM soundings collected, 3 were unusable as The average difference was +/-2.4 m. Differences could result a result of anthropogenic interference with the measurements. from (1) imprecision of depth interpolations from contours, The remaining 76 were categorized as type 1 (30), type 1a (9), (2) variation in the modeled thickness of the conductive layer type 1b (2), type 2 (17), type 3 (7), type 3a (1), and type 4 (10) depth resulting from measurement imprecision or model (appendix 4 and appendix 6, table 6-1). Only the 47 type equivalency, (3) depressions or highs in the paleosurface 1 and 2 models have a model layer interface that potentially over which the Biscayne aquifer was deposited that were not can be compared to the depth of the base of the Biscayne captured in the contours of Fish (1988) or Fish and Stewart aquifer (figs. 6-1 and 6-2). The type 1 and type 2 relations (1991), (4) intrusion of a portion of the semiconfining unit are summarized in table 6-1. Of the 47 type 1 and 2 relations, of the surficial aquifer system by saltwater, (5) imprecision 30, 53, and 81 percent of the models had a model-layer of land-surface altitudes, or (6) potential difficulties in interface that corresponded to the previously mapped base of interpreting the depth of the Biscayne aquifer from available the Biscayne aquifer within 1.0, 2.0, and 4.0 m, respectively. stratigraphic information.
Appendixes85 A. MIA108 B. MIA108 1,000 0 Estimated depth of base of Biscayne aquifer 100 50 Apparent resistivity, in ohm-meters Depth, in meters 10 100 1 150 0.001 0.01 0.1 1 10 1 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of ultra high saltwater saturated materials frequency data Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data Resistivities > 15 ohm-m indicate freshwater saturated materials Masked data Figure 6-2. Type 2 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
The largest differences between the estimated depth of to detect. Five of the seven sites where the differences ranged the base of the Biscayne aquifer and the selected model layer between 5 and 7.7 m are in the Model Land area. Fish and depth were 6.9, and 7.7 m, which occurred at measurement Stewart (1991, p. 38) used only three boreholes in this area for locations MIA122 and MIA202, respectively. The modeled their mapping effort, and the sparse distribution of boreholes layer thicknesses determined for measurement MIA202 in their mapping effort may have failed to identify variations were considered very good (Fitterman and Prinos, 2011). in the depth of the base of the Biscayne aquifer.
Measurement MIA202 may, therefore, indicate the pres- All of the type 3 and type 4 models determined from ence of an isolated but deep topographic depression in the measurements in the Model Land area and a few miles north paleosurface over which the Biscayne aquifer was deposited, of it indicate a decrease in resistivity occurring between or it may indicate that the differences in resistivity occurring depths of 11.8 and 18.9 m. These models have a highly near the base of the Biscayne aquifer were not large enough resistive (184-709 ohm-m) first layer and a less resistive
86 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A. MIA208 B. MIA208 1,000 0 Estimated depth of base of Biscayne aquifer 100 50 Apparent resistivity, in ohm-meters Depth, in meters 10 100 1 150 0.001 0.01 0.1 1 10 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of high frequency saltwater saturated materials data Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data and Resistivities > 15 ohm-m indicate error marker freshwater saturated materials High frequency data and error Model fit of ultra high frequency marker data Masked data Figure 6-3. Type 3 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
(21.1-60.0 ohm-m) second layer. The decrease in resistivity a recent USGS and FPL cooperative study (Wacker, 2010),
does not appear to be associated with the base of the Biscayne indicated flow zones at depths of approximately 14 to 17 m.
aquifer because there is ample hydrostratigraphic information Flow zones also were identified in wells G-3939 and G-3940 available in this area to place the depth of the base of the at depths of approximately 10 to 11 m. If laterally persistent, aquifer between 23 and 29 m. Hydrostratigraphic information these flow zones and perhaps the interaction of these flow includes logs from recently installed monitoring wells and zones with minor amounts of intruded saltwater (less than that numerous proximal type 1 and type 2 TEM models from normally associated with the saltwater front) may account which the depth of the base of the Biscayne aquifer can be for the changes in resistivity detected in the type 3 and interpreted. Geophysical logs collected in well G-3946, type 4 models of TEM soundings.
installed during this study (table 7-1), and test core holes TEM sounding MIA240 was a two-layer type 3 model G-3938, G-3939, and G-3940 (appendix 1), installed during that indicated a reduction in resistivity occurring at a depth
Appendixes87 A. MIA124 B. MIA124 1,000 0 100 50 Apparent resistivity, in ohm-meters Estimated depth of base of Biscayne aquifer Depth, in meters Estimated depth of base of surficial aquifer system 10 100 1 150 0.001 0.01 0.1 1 10 1 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of ultra high frequency data saltwater saturated materials Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data and error marker Resistivities > 15 ohm-m indicate freshwater saturated materials Figure 6-4. Type 4 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
of 72.9 m. Models of measurements MIA241 and MIA242, The conductive layers identified in type 4 models collected in the same area, also indicated decreases in resis- occurred at depths ranging from 49.6 to 98.1 m. These layers tivity occurring at depths of 65.1 and 76.4 m, respectively. correspond within 29 m to the base of the surficial aquifer The depth of the base of the surficial aquifer in this area is system in 7 of the 10 type 4 models. It is unknown if the estimated to be 86 m from the contour map of Fish (1988). base of the surficial aquifer varies this extensively because the distribution of boreholes used for the mapping effort was Considering that the contour in this area was based on only relatively sparse (Fish, 1988; Fish and Stewart, 1991). The one borehole and that the depth of the base of the surficial conductive layers identified in the remaining three type 4 aquifer may vary, the decreases in resistivity indicated by the models are at depths ranging from 35 to 45 m below the models of these TEM soundings may be associated with the estimated depth of the base of the surficial aquifer system and depth of the base of the surficial aquifer. may correlate to a unit within the Hawthorn Group.
88 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 6-1. Types of model relations and comparisons between the estimated depth of the base of the Biscayne aquifer in Miami-Dade and Broward Counties, Florida, and the depth of the selected model layers.
[NA, not applicable]
Relations between selected model Difference between estimated depth of the Percentage of relations for which the surfaces and estimated depth of base of the Biscayne aquifer and depth of estimated aquifer depth and selected layer depth base of Biscayne aquifer applicable model surface are within:
Number of Relation type relations of Maximum Minimum Average 1 Meter 2 Meter 4 Meter this type 1 30 7.7 0.1 2.3 33 60 80 1a 9 NA NA NA NA NA NA 1b 2 NA NA NA NA NA NA 2 17 5.6 0.1 2.7 24 41 82 3 7 NA NA NA NA NA NA 3a 1 NA NA NA NA NA NA 4 10 NA NA NA NA NA NA 1 and 2 combined 47 7.7 0.1 2.4 30 53 81 References Appendix 7. Description of Installation and Construction of Fish, J.E., 1988, Hydrogeology, aquifer characteristics, and groundwater flow of the surficial aquifer system, Broward Saltwater Front Monitoring Wells County, Florida: U.S. Geological Survey Water-Resources Investigations Report 87-4034, 80 p. Site Selection and Depths of New Monitoring Fish, J.E., and Stewart Mark, 1991, Hydrogeology of the surfi- Wells cial aquifer system, Dade County, Florida: U.S. Geological Sites for new saltwater monitoring wells were selected Survey Water-Resources Investigations Report 90-4108, to fill gaps in the existing salinity monitoring network, based 50 p., 11 sheets.
on a review of the spatial coverage provided by existing Fitterman, D.V., and Prinos, S.T., 2011, Results of time- monitoring wells and surface geophysical data. The eight domain electromagnetic soundings in Miami-Dade and new wells were named G-3885, G-3886, G-3887, G-3888, southern Broward Counties, Florida: U.S. Geological G-3946, G-3947, G-3948, and G-3949 (fig. 8). Some of Survey Open-File Report 2011-1299, 289 p. the new monitoring wells have sample tubes installed to collect water-quality samples in flow zones above or below Florida Division of Emergency Management, 2009, Miami- the saltwater interface, and A, B, C, D, and S Dade County 2 ft contour lines: Tallahassee, FL, Florida suffixes are added to the well name to differentiate between Division of Emergency Management, Shapefile, accessed the primary well and the sample tubes (table 7-1). In addition February 10, 2011, at http://www.floridadisaster.org/gis/ to the installation of new saltwater monitoring wells, the study index.asp. also included the collection of core and borehole geophysical logs (appendixes 8 and 9).
Wacker, M.A., 2010, Tools and data acquisition of borehole geophysical logging for the Florida Power and Lights Com-pany Turkey Point Power Plant in support of a groundwater, Drilling and Coring surface-water, and ecological monitoring plan, Miami-Dade County, Florida: U.S. Geological Survey Open-File Report Monitoring wells were drilled and constructed in two 2010-1260, 5 p., appendixes. phases. Four wells were drilled between June 30, 2009, and
Table 7-1. Construction and logging information from new wells installed in Miami-Dade County, Florida, during 2009-2011.
[NGVD 29, National Geodetic Vertical Datum; m, meters; >, greater than; S/cm, microsiemens per centimeter; cm, centimeters; NA, not applicable]
Latitude Number Longitude Base of Bottom (North), in Depth to Screen of Internal (West), in Altitude Altitude of Total depth Biscayne of tailpipe Local USGS station End date of degrees, water with interval separate diameter Description* degrees, of ground top of cored from aquifer from land identifier number construction minutes, > 5,000 from land stages of PVC pipe minutes, and surface (m) casing (m) surface (m) from land surface and µS/cm (m) surface (m) needed to (cm) seconds surface (m) (m) seconds log well G-3885 Primary well 253253080221201 8/18/2009 25-32-53.1 080-22-12.7 2.12 1.89 27.74 24.63 NA 23.16-24.69 26.21 1 5.08 G-3886 Primary well 253527080195401 10/2/2009 25-35-27.9 080-19-54.2 3.1 2.91 33.22 27.74 NA 26.21-27.74 30.78 1 5.08 G-3887A Primary well 253924080174601 9/25/2009 25-39-24.7 080-17-46.8 3.18 2.96 40.84 36.52 23.38 24.38-25.91 39.62 1 5.08 G-3887B Sample tube 253924080174602 9/25/2009 25-39-24.7 080-17-46.8 3.18 Not 40.84 36.52 23.38 19.51-21.03 22.56 1 2.54 Surveyed G-3888A Primary well 254542080145901 10/5/2009 25-45-42.7 080-14-59.8 4.31 4.17 45.35 41.76 29.57 31.55-34.59 43.74 2 5.08 G-3888B Sample tube 254542080145902 10/5/2009 25-45-42.7 080-14-59.8 4.31 Not 45.35 41.76 29.57 39.62-41.15 42.67 2 1.91 Surveyed G-3888C Sample tube 254542080145903 10/5/2009 25-45-42.7 080-14-59.8 4.31 Not 45.35 41.76 29.57 22.86-27.43 28.96 2 1.91 Surveyed G-3946D Primary well 252431080261001 6/22/2010 25-24-30.7 080-26-09.7 1.09 1 26.64 20.09 16.73 18.90-20.42 26.52 1 5.08 G-3946S Sample tube 252431080261002 6/22/2010 25-24-30.7 080-26-09.7 1.09 1.01 26.64 20.09 16.73 15.85-16.76 16.76 1 2.54 G-3947 Primary well 255011080124501 7/16/2010 25-50-11.3 080-12-45.4 3.57 3.48 69.49 54.01 None 51.82-54.86 60.96 1 (below 5.08 23.77 m)
G-3948D Primary well 255515080103601 10/13/2010 25-55-14.9 080-10-36.2 3.62 3.54 84.8 76.2 65.78 72.24-74.07 83.21 6 5.08 G-3948S Sample tube 255515080103602 10/13/2010 25-55-14.9 080-10-36.2 3.62 Not 84.8 76.2 65.78 35.51-37.03 37.03 6 2.54 Surveyed G-3949D Primary well 255733080195601 1/31/2011 25-57-33.6 080-09-56.5 3.75 3.62 106.46 84.04 NA 66.14-67.67 99.06 7 5.08 G-3949I Sample tube 255733080195602 1/31/2011 25-57-33.6 080-09-56.5 3.75 Not 106.46 84.04 NA 44.44-45.96 46.01 7 2.54 Surveyed G-3949S Sample tube 255733080195603 1/31/2011 25-57-33.6 080-09-56.5 3.75 Not 106.46 84.04 NA 15.24-16.76 16.81 7 2.54 Surveyed Monitoring wells with sample tube listed under description were constructed in the same borehole as the primary well with the same local identifier prefix, to obtain water-quality samples only.
Appendixes89
90 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater October 5, 2009, and the remaining four wells were drilled in core boxes and the approximate depth of retrieval, if known, between June 30, 2010, and February 3, 2011. A USGS Florida was indicated with wood blocks. Airlifting was considered Water Science Center hydrologist supervised the coring, data complete when the borehole was free of obstructions and collection, and well construction at each site. Decisions were the water from the borehole was free and clear of suspended made during drilling, regarding the need for additional lengths solids. Water clarity is an important consideration for optical of surface casing and the stability of the borehole. Borehole borehole image (OBI) logging.
geophysical logs were collected in stages (table 7-1) during At some sites, sand layers within the aquifer bridged the drilling at some sites. A steel casing was used to keep the across the borehole to create an obstruction. Bridging and borehole open to total depth due to sand infilling the borehole. infilling with sand required that these boreholes be drilled, Borehole drilling began at each site using a logged, and constructed in stages (table 7-1). Some of the 35.6-cm-diameter auger to drill a hole to the top of the first geophysical logs, such as the digital OBI logs, were incom-stable geologic unit, such as a well cemented limestone or plete because of the obstructions caused by the bridging of sandstone unit. A schedule 2, polyvinyl chloride (PVC) surface sand layers in these boreholes. In well G-3949, numerous casing with a 25.4-cm inside diameter was installed in the sand bridges were encountered during drilling.
hole produced by the auger and was grouted into place. The well was cored from the approximate top of the bedrock using Borehole Geophysical Logging Prior to Well a wire-line coring system to collect a 10.2-cm-diameter core samples to a depth below the base of the Biscayne aquifer and Construction into the uppermost part of the underlying semiconfining unit Geophysical logging was performed by the USGS in as determined by the USGS onsite hydrologist. Coring was each of the eight boreholes. Geophysical logs similar to those completed in 1.5-m intervals, and the time required to drill described in Wacker and Cunningham (2008) were collected to each foot (0.3 m) was recorded in a field log. Each 1.5-m core help identify (1) the base of the Biscayne aquifer, (2) zones of interval segment was brought to the surface; the core segment higher permeability, and (3) depth to water with conductivity, was removed from the core barrel by the USGS onsite compensated at 20 °C, greater than 5,000 µS/cm, if found hydrologist and placed in a 1.5-m-long PVC core-recovery within the boreholes. This information was used to determine tray while maintaining the correct vertical stratigraphic the optimal design specifications for the new monitoring wells.
orientation. The core segment was washed to remove drilling These new monitoring wells were designed to monitor the cuttings and fluids and was placed in a 0.6-m-long cardboard deepest preferential groundwater flow zone identified within core box with wooden blocks marked with the drillers depth the formations that comprise the Biscayne aquifer. Additional placed at the bottom of each core segment. The core segment sample tubes were added if the geophysical logs indicated was then marked by using paint pens with two continuous other permeable zones of interest. Geophysical logging vertical lines (one black and one red) running parallel to the commenced within about 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of completion of airlifting long axis of the cylindrical core samples. When the core is to allow suspended sediment in the borehole fluid column to oriented in the correct vertical orientation with respect to the settle. The 24-hour waiting period was generally sufficient to strata in the aquifer, the red line is on the right side of the produce clear formation fluid in the borehole required for the core and the black line is on the left. This marking convention OBI log. In some wells, geophysical logs (caliper, gamma, prevents inadvertent inversion of core segments. The length of spontaneous potential, single point resistance, electromagnetic the core segment recovered from each 1.5-m core interval was induction, and full waveform sonic) were run immediately entered in a field log. after the airlift development because these logs are not A liquid polymer mud was added as necessary to the affected by borehole water clarity.
drilling fluid to facilitate collection of unconsolidated sand and soft sediment in the core barrel and to allow their extrusion Borehole Image Logging from the barrel at the surface. The polymer mud also provided lubrication and facilitated the removal of cuttings. The At each borehole drilled for this study, two types of polymer breaks down within a few days and is easily removed geophysical borehole imaging tools were used: the Mount from the column of borehole fluid during a borehole purging Sopris OBI MK-IV digital OBI tool and a Mount Sopris process called airlifting. Once coring was completed to the ABI-40 digital acoustic borehole imaging (ABI) tool. The desired total depth below the Biscayne aquifer, the wire-line OBI log was collected first, using 95 percent light and coring casing was removed. The borehole was prepared for 720 turns (or every half degree of circumference), and logging by evacuating loose clay, silt, and sand to cobble-sized was sampled vertically every 0.82-mm of depth. Then the (up to 7.6 cm diameter) material from the borehole with an ABI-40 digital acoustic borehole imaging (ABI) log was airlift device constructed by the drilling contractor. As water collected using 288 turns (or every 1.25 degrees of circumfer-was purged from the borehole by using this device, it was ence) and was sampled vertically every 1.68 mm of depth.
replaced by water from the aquifer. This flow aids removal Both OBI and ABI tools acquired data while logging upward of drilling fluids and improves water clarity. Any noteworthy from the bottom of the borehole to the land surface or from the samples brought to the surface during airlifting were archived bottom of casing if the borehole was logged in stages.
Appendixes91 Borehole Fluid and Caliper Logging an acoustic signal transmitted at 15 kilohertz (kHz; used for porosity calculations) and one transmitted at 1 kHz (used A Mount Sopris Idronaut 303 (Mount Sopris 2IFA-1000) for relative permeability estimations). The full waveform water-quality tool was used at each site to collect logs of sonic logs were not collected from wells that were logged fluid temperature, conductivity compensated at 20 °C , pH, in multiple stages when the length of logging stage was less dissolved oxygen (in percent), and oxidation reduction poten- than 6.1 m because the 3.0-m tool length would not provide tial. The conductivity measured by this probe is not the same useful information in a short interval. The full waveform sonic as specific conductance because specific conductance is typi- logs were processed by using Log CruncherTM software. Log cally normalized to a temperature of 25 °C. The water-quality Cruncher is used to determine the mean primary compres-tool acquired data while logging upward and downward in the sional wave and Stoneley wave velocities. The compressional borehole. After the first four wells were completed, and before wave velocity is used as input into the Raymer-Hunt porosity construction of the last four was begun, the water-quality tool equation for calculation of sonic porosity (Raymer and was returned to the manufacturer for repairs of a sensor and for others, 1980). Sonic porosity values calculated from compres-re-calibration. The water-quality tool was fully calibrated and sional wave velocities are typically higher than whole-core functioned properly at all sites. In addition, the water-quality laboratory porosity measurements. Known values of tool calibration was checked with a separate and independently laboratory-measured porosity of rock cores were not available calibrated conductivity meter during logging. to calibrate a computed porosity curve. The amplitude of the At sites where the borehole was filled with freshwater, Stoneley wave also was measured from the receiver closest a Mount Sopris 2FSB-1000 fluid probe, which was attached to the transmitter (receiver 1). The Stoneley wave amplitude to the bottom of a Mount Sopris 2CAA-1000 three-arm has a predictable qualitative relation to permeability, which caliper tool, was used to acquire fluid temperature and can be used to estimate a qualitative permeability of the rock resistivity measurements while logging downward from surrounding the borehole. Generally, low amplitudes can land surface. Temperature and resistivity were automatically represent relatively high permeability, and high amplitudes can used to compute fluid conductivity and specific conductance represent relatively low permeability. The computed value, (appendix 8). Fluid probe data were used for comparison with therefore, can be used in a qualitative and conservative sense the water-quality tool when available. Caliper logging with to estimate zones of relatively high and low permeability.
the caliper tool was then performed to determine the borehole diameter. These logs were collected in an up-hole direction. Flowmeters Flowmeter logging of each borehole was completed Induction, Natural Gamma-Ray, Spontaneous under both ambient (static) and dynamic (pumping) condi-Potential, and Single-Point Resistance Logging tions. Three different types of flowmeters were used during the study because of the variability in borehole fluid conditions.
After the caliper log was collected, logs were collected Saline fluids are more conductive and appear to have an using a Mount Sopris 2PIA-1000 electromagnetic induc-effect on the performance of the electromagnetic flowmeter tion tool, an HLP-2375/S natural gamma-ray tool, and and, to a lesser degree, on the performance of the heat-pulse a combined spontaneous potential (SP) and single-point flowmeter. The spinner flowmeter is not affected by the resistance (SPR) tool. Induction logs were collected in the conductivity of the borehole fluid. Each borehole was pumped up-hole and down-hole directions. The natural gamma-ray using a 5.08-cm-intake-diameter centrifugal water pump with log was collected in an up-hole direction, and the sponta- the suction line placed below the water table within the open neous potential (SP) and single-point resistance (SPR) logs borehole. Flow rates were measured by timing the rate at were collected in a down-hole direction. The Mount Sopris which discharge water filled a 75.7-L container and are shown 2PIA-1000 electromagnetic induction tool was calibrated on each log heading (appendix 8). Pumping rates during as described in preceding sections of this report. A final geophysical logging ranged from 121 to 477 L/min. Rates electromagnetic induction log was collected in each of the varied depending on depth to water and length of discharge completed 5.1-cm-diameter monitoring wells. The natural hose. Flowmeter logs were not collected from any boreholes gamma-ray tool and SP/SPR tool do not require calibration (G-3888, G-3947, G-3948, and G-3949) with geophysical and provide relative values that can be compared with other logging intervals less than 6.1 m in length.
logs collected with the same tool. Once the image and caliper logs were collected at each borehole, a draft of these logs was plotted in the field to deter-Full Waveform Sonic mine optimum depths for the collection of stationary measure-ments of vertical borehole fluid flow using the flowmeters. A Upon completion of induction, natural gamma-ray, Mount Sopris HPF-2293 heat-pulse flowmeter with an 18-cm SP, and SPR logging, a Mount Sopris 2SAA-1000/F full petal diverter was set at each predetermined depth, and at least waveform sonic tool log was collected from each borehole. three measurements were collected at each stationary depth Two logs were collected by using the sonic tool: one with under ambient borehole fluid-flow conditions.
92 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Following logging with the heat-pulse flowmeter, a tip of the induction logging tool usually encounters the bottom Century Geophysical 9721 electromagnetic flowmeter was of the well before a full response to materials at the aquifers used to log by trolling up and down the borehole to create a base can be achieved. To improve the quality of data collected, continuous log of vertical borehole fluid flow under ambient the new monitoring wells incorporated several design features conditions. The electromagnetic flowmeter also contained a (fig. 7-1) not previously implemented in the USGS network sensor to measure borehole fluid temperature and resistivity, in this area: (1) additional casing that extended below the which were recorded. After the ambient borehole fluid flow screen and somewhat deeper than the base of the Biscayne was measured while trolling, a centrifugal pump was used aquifer, (2) installation of secondary filter packs in zones of to draw water from the well at a constant rate. Once the flow high porosity, and (3) installation of secondary sampling tubes and drawdown stabilized, the electromagnetic flowmeter log in selected secondary filter packs. By adding additional casing was collected in the borehole under pumping conditions. The below, a full response can be recorded within the screened electromagnetic flowmeter acquired stationary pumping flow interval. The additional casing can also allow measurement of measurements at the same depths as those acquired by the changes occurring near the top of the semi-confining unit of heat-pulse flowmeter under ambient conditions. The electro- the surficial aquifer to determine if saltwater also is intruding magnetic flowmeter also provided logs of fluid temperature into these sediments.
and resistivity (appendix 8).
Large solution cavities in the limestone of the Biscayne In some boreholes that were logged in stages, the lowest aquifer likely would allow the cement grout of the annular stage was logged with either a Mount Sopris FLP-2492 seal to flow into the formation. This grout could prevent spinner flowmeter or an electromagnetic flowmeter during formation water from entering the 20- to 100-cm radius of pumping to determine flow zones. Ambient flow informa-tion was not collected in wells where the upper part of the investigation of the induction logging probe. The installation borehole was cased because there would not be a head of secondary filter packs at depths where large solution difference between the lower and upper flow zones to cause cavities occur allows formation water to flow unimpeded in ambient flow. close proximity to the well casing so that the formation water can be measured by the induction probe. Small-diameter sample tubes were installed in some of the secondary filter Geophysical Log Analysis packs so that the water in highly transmissive flow zones could be sampled.
Following acquisition of all geophysical logs in the Historically, drill cuttings were used to evaluate the field, the raw log data were processed and displayed by using stratigraphy and to help determine the depths of the intakes of Advance Logic Technology, WellCAD version 4.3, and were some of the monitoring wells used for collection of TSEMIL saved in Adobe Systems Incorporated Portable Document datasets. Evaluations of drill cuttings alone could result in a Format (PDF) at 1:48 scale (appendix 8). Final monitoring- well intake too deep to provide water samples from the depth well completion zones are shown on the final log montage interval where there are changes in bulk conductivity. For with depths relative to land surface. example, this situation occurred at well G-3701 (fig. 33A).
The geophysical logging during this study allowed the identifi-Well Completion cation of the deepest flow zones within the Biscayne aquifer so that the screened interval of the 5.1-cm-diameter monitoring By using the information provided by geophysical and well could be placed in this flow zone. Additional casing was water-quality logging (appendix 8), the monitoring wells were added below the screen to ensure that the induction tool would designed to (1) penetrate the full thickness of the aquifer and be able to record data across the boundary between the base of a shallow depth below it, into the upper portion of the semi- the aquifer and the semi-confining unit of the surficial aquifer.
confining unit of the surficial aquifer, (2) provide samples In some instances, such as for well G-3949, the tailpipe from the deepest flow zone occurring within the formations extends to a much greater depth below the screened interval so that comprise the Biscayne aquifer, and (3) allow sampling of that identified zones of weak flow within the semi-confining shallower flow zones or saltwater interfaces through sample unit of the surficial aquifer can be monitored. Secondary tubes. Table 7-1 provides well construction information sampling tubes were installed in five of the eight boreholes.
for the eight wells installed during this study. The depth to Once the well design was completed, construction began water of conductivity, compensated at 20 °C, greater than by backfilling the borehole with 20-30 grade sand to the 5,000 µS/cm also is provided because water of this conduc- designed depth of the bottom of the added casing. Then the tivity generally has a chloride concentration of 1,000 mg/L well casing and screen were assembled and inserted into the or greater. A chloride concentration of 1,000 mg/L has been well. More fine sand was added to a depth about 1.2 m below used historically for mapping the inland extent of saltwater in the screen, and then a layer of time-release bentonite pellets southeast Florida. and sand was installed that extended to within approximately Many of the pre-existing monitoring wells were designed 0.6 m of the bottom of the screen. A filter pack consisting of such that the bottom of the well would be at about the same pea gravel was used to fill the screened interval from 0.6 m depth of the base of the Biscayne aquifer. In this design, the below the interval to 0.6 m above the top of the interval. Then
Appendixes93 Depths of screen intervals, and seals are based on results of geophysical logging Locking well plug Possible surface casing 1-meter-diameter depending on materials cement well pad at surface about 0.3 meter thick 20- to 30-centimeter-diameter metal Pea gravel to allow drainage protective well cover with bolt-down lid of protective cover Sample tube for collecting water Casing: 5-centimeter-diameter, samples from flow zones schedule 40 PVC, screw-together flush joints with o-ring seals Solution cavities 15- to 20-centimeter-diameter hole Secondary filter pack. Annular seal Sand or pea gravel fill to neat cement prevent cement from running into formation Bentonite pellet seal minimum 0.3 meter thick Screen- 5-centimeter diameter, PVC, 1.5-meters long, screw-together flush joints with o-ring seal Sand seal 0.6 meter thick Filter pack pea gravel Encroaching sea water Additional length of casing to allow full response from logging equipment BASE OF AQUIFER Hole may be drilled deeper to explore hydrology and then backfilled Well plug Figure 7-1. Illustration showing design of new monitoring wells installed during the study to monitor saltwater intrusion into the Biscayne aquifer, Miami-Dade County, Florida.
94 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater successive layers of sand and bentonite pellets were added to create a seal above the filter pack that would prevent grout from Appendix 9. Hydrostratigraphic filling the filter pack. In the deeper wells (G-3947, G-3948, and Analysis G-3949), the material was added by using a 2.5-cm-diameter PVC tremie pipe. The annular seals of wells were grouted in Continuously drilled core samples from the eight new stages. A 190-L barrel (about 4 bags) of grout was added at a monitoring sites and related borehole geophysical logs were time, and this grout was allowed to set overnight. If a sample examined in the USGS core laboratory in Davie, Florida.
tube was installed to monitor a flow zone, the previously Geologic, geophysical, and hydrologic data from the eight described procedure for creating a filter pack was used to boreholes form the fundamental basis for a generalized complete that interval. If a sample tube was not installed in the hydrostratigraphic framework of the surficial aquifer in central identified high flow zone, it was filled with a layer of coarse to northern coastal Miami-Dade County, which is described (6-20 grade) sand that extended about 1 m above and below herein. The information obtained from the new wells was used the flow zone. This layer of sand was capped with a layer of to map on a two-dimensional section the lithostratigraphic and bentonite pellets and grout to prevent the movement of water in hydrostratigraphic units (fig. 9-1). The lithology and extent of the annular space. Pea gravel filter packs, sample tubes, seals, the lithostratigraphic units were determined by examination and grout were installed as necessary to complete the well of continuously drilled cores and borehole-geophysical logs installation. Near the surface, a grout layer was added to within (especially digital optical borehole wall images).
a few feet of land surface to seal the well from surface water.
After the grout was set, the manhole was constructed by adding sand above the grout to the base of the manhole to allow for Correlation of Lithostratigraphy and drainage. Then a concrete pad was constructed. Hydrostratigraphy of Eight New Boreholes After the wells were completed, Miami-Dade County surveyed the top of each casing and the manhole, and a final Correlation of the basic lithostratigraphy represented electromagnetic induction log was run in each completed in the eight boreholes drilled for this study is shown in monitoring well. Field notes were collected during drilling, figure 9-1. Zones of groundwater flow within and delimiting logging, and construction, and a PDF file was then made of the base of the Biscayne aquifer in these eight wells were all logs. Well information was entered into the USGS Ground defined by using the results of the examination of pore systems Water Site Inventory (GWSI) system for future reference, and in lithologic cores and in digital optical borehole wall images the geophysical logs were archived for future use. and the evaluation of flowmeter logs combined with borehole-fluid conductivity and temperature log data. Interpretations of this information indicate that the surficial aquifer within the study consists mostly of the Tamiami Formation, Fort References Thompson Formation, Miami Limestone, and the intermediate confining unit comprised of the Stock Island Formation Raymer, L.L., Hunt, E.R., and Gardner, J.S., 1980, An (figs. 6 and 9-1). The hydrogeologic cross section displayed improved sonic transit time-to-porosity transform, paper P, in figure 9-1 is oriented oblique to the strike of depositional in 21st Annual Logging Symposium Transactions: Society facies belts of the Pliocene-Pleistocene depositional systems of Professional Well Log Analysts, 12 p. that comprise the Stock Island Formation, Tamiami Formation, Fort Thompson Formation, and Miami Limestone. Thus the Wacker, M.A., and Cunningham, K.J., 2008, Borehole geo- lithologies encountered in the southern boreholes represent physical logging programIncorporating new and existing more shoreward facies belts that are oriented generally parallel techniques in hydrologic studies: U.S. Geological Survey to paleoshorelines, and the northern boreholes intersect facies Fact Sheet 2008-3098, 4 p. belts mostly parallel and proximal to the Pliocene-Pleistocene paleoshelf margins.
Until recently, the Stock Island Formation was only defined in the western Florida Keys (Cunningham and Appendix 8. Geophysical Logs others, 1998), but is now recognized in Miami-Dade County at the G-3948 and G-3949 test boreholes (fig. 8). In the two Geophysical logs collected in the eight new wells were test boreholes, the lithology of the Stock Island Formation is evaluated using WellCADTM software. WellCADTM files are characterized by skeletal fragment, planktonic foraminiferal provided as supplemental files. AdobeTM Portable Document lime packstone and grainstone, which in some cases is very Format (PDF) files are also provided in the supplement files, quartz-sand rich. The Stock Island Formation occurs subjacent but the ability to view all logs in detail is limited by this format. to the Tamiami Formation in the test boreholes G-3948 and G-3949 (fig. 9-1), but on a regional scale is generally See supplemental files in the folder http://pubs.usgs.gov/ equivalent to the Tamiami Formation. In Broward County, sir/2014/5025/appendix/sir2014-5025_appendix_08. the Stock Island Formation is shown on the Hillsboro Canal
Appendixes95 B 66.9 km B' SOUTH 16.9 km 6.1 km 8.0 km 12.6 km 9.0 km 10.0 km 4.3 km NORTH G-3946 G-3885 G-3886 G-3887 G-3888 G-3947 G-3948 G-3949 NGVD 1929 NGVD 1929
?
?
-10 -10
?
?? ??
?? Surficial
?? Aquifer
? System
-20 -20
?
Biscayne
-30 ? Aquifer ? -30
??
?
Altitude, in meters relative to NGVD 1929 Altitude, in meters relative to NGVD 1929
?
?
-40 -40
?
?
-50 -50
?
-60 Se ? -60 mi co Un nfin it ing
-70 -70
?
-80 -80 Intermediate 80°40' 80°20' 80°00' Confining 26°00' B' ? Unit LEE COUNTY BROWARD COUNTY
-90 ! -90 OCEAN MIAMI-DADE COLLIER COUNTY
-100 COUNTY -100 ATLANTIC 25°40' !
! EXPLANATION
! Soil or fill or both Limestone Miami Limestone Quartz sand
! Fort Thompson Formation Sandstone B
Tamiami Formation No recovery 25°20' Stock Island Formation Flow zone Not interpreted Slotted casing 0 5 10 KILOMETERS EXPLANATION Hydrostratigraphic boundary Cased well B B' 0 5 10 MILES Cross section Lithostratigraphic boundary Drilled and then
! New USGS salinity backfilled monitoring well ? Lithology uncertain Figure 9-1. Illustration showing the cross section oblique to depositional strike of the upward transition from Pliocene-to-Pleistocene mixed carbonate-siliciclastic ramp to platform that comprise the surficial aquifer system and intermediate confining unit of central and northern coastal Miami-Dade County. The southern part of the cross section is substantially west of the present-day and Plio-Pleistocene shelf margin as compared to the northern part of the cross section.
96 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater seismic profile to be, at least in part, equivalent to the Ochopee Fish, J.E., and Stewart Mark, 1991, Hydrogeology of the surfi-Limestone Member of the Tamiami Formation. Chronostratig- cial aquifer system, Dade County, Florida: U.S. Geological raphy by Guertin (1998) indicated that on Stock Island in the Survey Water-Resources Investigations Report 90-4108, Florida Keys, the Stock Island Formation is mostly the same 50 p., 11 sheets.
age as the Tamiami Formation. Cunningham and others (1998) delineated the Stock Island Formation as mainly equivalent to Guertin, L.A., 1998, A late Cenozoic mixed carbonate/silici-the Long Key Formation, and thus entirely or mostly restricted clastic system, south FloridaLithostratigraphy, chro-to a Pliocene age. Minor groundwater flow zones are defined nostratigraphy, and sea-level record: Miami, University of in the Stock Island Formation in these test boreholes and Miami, Ph.D. dissertation, 335 p.
provide examples of minor aquifer zones within the interme-diate confining unit. It is likely that the Stock Island Formation Reese, R.S., and Cunningham, K.J., 2000, Hydrogeol-is a low permeability, relatively deeper-water, outer-ramp ogy of the gray limestone aquifer in southern Florida:
equivalent to units within the Tamiami Formation that are U.S. Geological Survey Water-Resources Investigations much better defined to the west (Reese and Cunningham, Report 99-4213, 244 p.
2000). New continuously drilled cores that span the complete thickness of the Biscayne aquifer, advanced geophysical logs, and new seismic profiles in canals and offshore in Biscayne Bay and the Atlantic Ocean (e.g., Cunningham and Appendix 10. Geochemical Sampling Wacker, 2009) are providing the information necessary to reinterpret the hydrogeologic setting described by Causaras Methods (1987) and Fish and Stewart (1991).
A total of 52 groundwater samples were collected from 34 wells, and 17 surface-water samples were collected from Core Descriptions 10 surface-water monitoring sites by using a submersible pump, centrifugal suction pump, or Kemmerer water sampler.
Core descriptions from the eight new wells installed The sampling method used to collect each sample is provided during the study are provided in a supplementary Adobe in table 2-1. Site selection and sampling method were based Acrobat TM Portable Document Format file. General informa- on type of site (surface water or groundwater), well construc-tion concerning site location, core-hole depth, and available tion, well installation date, location, and the purpose of each borehole geophysical logs is provided for each of the cores sample. Sites were selected on both sides of the leading edge described. The depths to the top of the Miami Limestone, the of the saltwater front. Wells near canals and farther away from Fort Thompson Formation, and the Tamiami Formation are canals were selected for comparison purposes.
included in this general information. Wells with short open intervals situated near the base of the aquifer are able to provide the most reliable information See supplemental file http://pubs.usgs.gov/sir/2014/5025/ concerning the inland extent and age of saltwater in the appendix/sir2014-5025_appendix_09.pdf. aquifer. In some areas, however, the only available monitoring wells have long open intervals. In long open-interval wells, water of different ages and chemical compositions potentially could mix, which could greatly reduce the value of samples References collected for age dating and evaluation of maximum salinity in the aquifer.
Sampling and decontamination procedures generally Causaras, C.R., 1987, Geology of the surficial aquifer system, adhered to those described in the USGS National Field Dade County, Florida: U.S. Geological Survey Water-Manual for the collection of water-quality data (U.S. Geolog-Resources Investigations Report 86-4126, 240 p., 2 sheets.
ical Survey, variously dated), but procedures documented on Cunningham, K.J., McNeill, D.F., Guertin, L.A., Ciesielski, the websites of the USGS Chlorofluorocarbon Laboratory in P.F., Scott, T.M., and de Verteuil, L., 1998, New Tertiary Reston, Virginia (U.S. Geological Survey, 2011a, b, c), and stratigraphy for the Florida Keys and southern peninsula methods similar to those described by Kohout and Hoy (1963) of Florida: Geological Society of America Bulletin, v. 110, also were used.
no. 2, p. 231-258. A Fultz TM SP-400 submersible pump with 100% Teflon lines was used to collect groundwater samples. Each sample Cunningham, K.J., and Wacker, C., 2009, Seismic-sag collected using this pump was processed in a chamber that structural systems in Tertiary carbonate rocks beneath consisted of a clear, virgin, poly-resin, disposable bag. The southeastern Florida, USAEvidence for hypogenic bag prevented contamination by dust and cross-contamination speleogenesis? in Klimchouk, A.B., and Ford, D.C., between samples. Temperature, pH, dissolved oxygen, and eds., Hypogene speleogenesis and karst hydrogeology specific conductance were monitored with a calibrated YSI of artesian basins: Simferopol, Ukraine, Ukrainian Insti- Professional PlusTM multimeter and a flow-through chamber.
tute of Speleology and Karstology, Special Paper no. 1, Turbidity samples were periodically collected during
- p. 151-158. purging by using a HachTM 2100P portable turbidity meter.
Appendixes97 Hydrogen sulfide was evaluated with a Hach HS-WR 0- to Sample Analysis and Quality Assurance 11.25-mg/L test kit at selected sites. Samples collected by using the submersible pump were evaluated to determine the Major and trace ion analyses were conducted at the concentrations of the full suite of analytes, including barium, USGS National Water Quality Laboratory in Denver, boron, bromide, calcium, chloride, fluoride, iron, magnesium, Colorado, by using the methods described in Clesceri and potassium, silica, sodium, strontium, sulfate, tritium, uranium, others (1998), Fishman and Friedman (1989), Fishman (1993),
tritium (3H), alkalinity, pH, temperature, specific conductance, Garbarino (1999), and Garbarino and others (2006). The turbidity, dissolved oxygen, and the isotopic ratios of tritium concentrations in water samples (table 2-3) were eval-18 O/16O and 2H/1H. Selected sites were sampled to evaluate uated by the USGS Stable Isotope and Tritium (USGS-SI&T)
(1) the age of the water by using 3H/3He and SF6 age-dating Laboratory in Menlo Park, California, by using electrolytic methods, (2) the isotopic ratio of 87Sr/86Sr, (3) dissolved gas enrichment and liquid scintillation. The 87Sr/86Sr isotope ratios composition, and (4) terrigenic helium concentration. were analyzed by the USGS Metal and Metalloid Isotope A small, 4-stroke, variable-speed, gasoline-powered Laboratory in Menlo Park, California, as described in Katz HondaTM WX10 centrifugal suction pump was used to sample and Bullen (1996). Alkalinity was analyzed by titration with a surface-water sites. The centrifugal pump could pump at rates Hach Universal Digital Titrator and 1.600 +/- 0.008 N sulfuric up to 60 L/min, but could not pump at rates as slow as the acid by using the inflection point method. Titrations were Fultz submersible pump. The speed of the centrifugal pump usually performed twice for each sample, and the average was too great to allow the use of the flow-through chamber, alkalinity and bicarbonate concentrations were computed.
so probes from either the YSITM Professional Plus multimeter or an OaktonTM pH/Con 10 series multimeter were placed in Alkalinity, terrigenic helium, and dissolved gas samples were a bucket receiving discharge from the pump. The flow rate kept refrigerated until analyzed.
of the suction pump was more than sufficient to exchange Dissolved gas composition (table 2-2) and SF6 water in the bucket as rapidly as the submersible pump had concentrations (table 2-4) were analyzed by the USGS exchanged water in the flow-through cell. Dissolved oxygen Chlorofluorocarbon laboratory in Reston, Virginia, following was not measured. The centrifugal pump was decontaminated the procedures described in USGS (2011d, i). The USGS between samples by using the same procedures that were used Chlorofluorocarbon laboratory also evaluated the terrigenic on the submersible pump. To facilitate sampling, a valve was helium in water samples with a Hewlett Packard 5890 Series installed in the discharge line, which allowed a part of the gas chromatograph. The isotope compositions of oxygen and pump discharge to be diverted to a small-diameter sampling hydrogen expressed in terms of 18O and 2H (table 2-7) were line to which a filter could be attached. The centrifugal pump determined by the USGS-SI&T as described in Révész and was only used to collect samples for the evaluation of major Coplen (2008a, b).
ion and tritium concentrations and the stable isotope ratios 3 H/3He age dating was performed by the Lamont-Doherty of oxygen and deuterium. These parameters were deemed Earth Observatory Noble Gas laboratory at the Earth Institute at sufficiently stable for sampling by using this method. Columbia University (CU-LDEO) in Palisades, New York. The The long open-interval wells FKS4, FKS7, and FKS8 CULDEO laboratory determined the concentration of tritium by (appendix 1) were sampled with a Kemmerer water sampler. helium ingrowth. They also determined the concentrations of A flow-through cell could not be used with the Kemmerer. helium and neon and the isotope ratios of 3He/4He. Additional Instead, once the Kemmerer was retrieved from the well, a information concerning the methods used for mass spectrom-small part of the sample was placed in a cup that held the etry of helium isotopes and for measurement of the tritium probes of the multimeter for evaluation of pH, temperature, concentration in water samples by the 3He ingrowth method is and specific conductance. Measurements of these parameters in provided by Ludin and others (1997). Ages were determined by samples collected in this manner may not be fully representa- using the relation of Schlosser and others (1988):
tive of aquifer conditions because of the changes in pressure and temperature that can occur during measurement. The Kemmerer could only be used to collect samples for analysis of T1/ 2 3 Hetrit major ion and tritium concentrations and oxygen and deuterium t= ln 1 + 3 , (10-1) ln 2 H stable isotope ratios because of the small sample volume and because the sample comes into contact with the air when released from the Kemmerer. It should be noted that sampling where t is the 3H/3He age in years, 3Hetrit is the concentration with a Kemmerer does not avoid the problem of mixing as a of tritiogenic helium, T1/2 is the half-life of tritium, and result of ambient vertical flow in the borehole. Site set-up and 3
H is the concentration of tritium. The amount of 3Hetrit cleaning procedures used for Kemmerer sampling were similar derived from radioactive decay of 3H in the water sample is to those used for samples collected with the submersible pump. determined by using a helium isotope mass balance (Schlosser Dissolved gas samples (table 2-2) generally were not and others, 1988). The helium concentration of groundwater collected at surface-water sampling sites because they are can be enriched by terrigenic helium, which can interfere in used to evaluate the temperature of the water at the time that the mass balance used to compute amount of 3Hetrit derived it entered the aquifer. These samples were only collected at from radioactive decay. The neon concentration of the water selected sites. sample, which is assumed to be derived solely from the
98 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater atmosphere, is used to calculate the amount of additional samples from G-3600 were negative, which indicates that 3
Hetrit (Schlosser and others, 1989). To determine if the gas fractionation has occurred and that the age of this sample terrigenic helium concentration in samples is excessive, the is questionable. Analyses of samples collected from wells concentrations of helium, hydrogen, and neon in samples G-3608, G-896, and G-894 and the C2 Canal at G-3608 were determined by the USGS Reston Chlorofluorocarbon indicated respective 4He/Ne ratios of 0.7, 0.7, 0.8, and Laboratory (USGS-RCL) using gas-chromatography, and 0.5. These results indicate that gas fractionation may have the concentration of helium that is in excess of the air-water occurred. Gas fractionation of canal water seems reasonable equilibrium (4He) was computed using the relation given that the canal water is always in contact with the atmo-sphere. The samples from wells G-896 and G-3608, which are 0.38 km and 8 m, respectively, from the Snapper Creek 4 Hes 4 Heeq Canal, also could be affected by gas fractionation; however, 4 He = 4 x100 , (10-2) the locations of these wells relative to the Snapper Creek Heeq Canal, the extraordinary permeability of the Biscayne aquifer, and the concordance of the samples collected in this area with where 4Hes is the helium concentration of the sample and respect to the 4He/Ne ratios indicate that the 3H/3He ages 4
Heeq is the air-water equilibrium concentration of helium. from these wells may be reliable. Samples from wells G-896 If the 4He is positive, the sample contains excess air or and G-3608 indicated interpreted piston-flow ages that date to terrigenic helium. If the tritium concentration is greater than about 1998 and 1997, respectively (table 2-5).
0.5 TU and if 4He is less than 200 percent, 3H/3He age The results of tritium analyses provided by the dating is likely to be successful. Corrections for terrigenic CU-LDEO lab (table 2-5) were used for 3H/3He age dating helium were applied to samples that indicated that terrigenic and are of greater precision than analyses provided by the helium was greater than 5 percent. If the 4He is negative USGS-SI&T laboratory (table 2-3). The analyses by the by more than a few percent, the sample may have degassed USGS-SI&T were used to ensure that tritium levels were and may not be able to be dated. The precision of analyses within the acceptable range for analysis by the CU-LDEO of the dissolved gases helium, hydrogen, and neon are lab and would not contaminate the CU-LDEO lab. Samples respectively 20, 10-20, and 10 percent (Busenberg and analyzed by the USGS-SI&T laboratory also were used to others, 2000; Eurybiades Busenberg, U.S. Geological Survey, evaluate tritium concentrations in the aquifer. The standard written commun., May 25, 2011). All but one of the samples deviation of analyses for all samples evaluated by the (well G-3609) had 4He values of less than 200 percent CU-LDEO laboratory for this study ranged from 0.04 to (table 2-6). The 4He of the samples collected from well 0.91 TU, whereas the standard deviation for analyses by the G-3609 on July 30, 2009, and December 17, 2009, were USGS-SI&T laboratory ranged from 0.4 to 1.7 TU. Analytical 8.5 and 215.3, respectively. Given this large discrepancy, the results from the CU-LDEO were used to determine analytical sample collected on December 17, 2009, may have had an ages and interpreted piston-flow ages. The analytical ages air bubble that was not identified during sampling. Excluding were determined using the analytical results of the CU-LDEO, the one sample from G-3609, the 4He ranged from 0.1 to measured salinity of the each sample, the approximate altitude 154.9 percent and averaged 36.6 percent. The 4He was not of each sample location, and the recharge average recharge negative in any of these samples; therefore, these samples temperature determined from dissolved gas analyses. A crustal potentially could be used for 3H/3He age dating. terrigenic 3He/4He ratio of 2.00 x 10-8 was used. The half-life The 3H/3He age-dating results provided by the CU-LDEO of tritium used was 12.32 years. Interpreted piston-flow ages laboratory also included determinations of 4He. The analyses were determined based on the determined ages and amount by the CU-LDEO laboratory were generally higher in preci- of tritium. Samples with very low tritium are considered to sion than those that could be obtained by the USGS-RCL provide only a very coarse understanding of age. Samples using gas chromatography. The 4He in samples determined that have analytical ages older than 1970, which is considered by the CU-LDEO laboratory ranged from 2.6 to 71.7 percent beyond the practical range of this dating method, were (table 2-5). Terrigenic helium corrections were applied to assigned interpreted piston-flow ages of < 1970. Most inter-3 H/3He age dates of all samples that had terrigenic helium preted piston-flow ages are considered approximate, because concentrations that were greater than 5 percent. of the uncertainties in recharge temperature, gas fractionation, Excess air in samples also can potentially interfere with and the 3He/4He ratio.
3 H/3He age-dating analyses. Samples for which the Ne and A 3H/3He age-dating sample was collected from only one 4He/Ne ratios are negative indicate that gas fractionation surface-water site because surface water typically is consid-occurred. Where the 4He/Ne ratio is less than 1, it is also ered to be in relatively close equilibrium with the atmosphere possible that some gas fractionation may have occurred. and therefore would have an age near zero. The surface-water When water comes in contact with air, the helium tends to sample was collected to determine if older groundwater was diffuse more rapidly into the air than neon. If gas fractionation flowing into the canal in sufficient quantities to be detected.
removed parent or daughter products from the system, it 3 H/3He age-dating samples were not collected from long could invalidate the determined age. The Ne and 4He/Ne screened wells or from newly installed wells where the mixing ratios were computed for samples analyzed by the CU-LDEO of water caused by sampling or well installation would affect laboratory (table 2-5). The Ne and 4He/Ne ratios in the ages determined.
Appendixes99 Quality-Assurance Samples was lost. The absolute value of the difference between the analytical results of each pair of original and replicate Replicate samples consisted of two or more sets of samples was divided by the arithmetic mean of these results to samples collected concurrently so that both samples are determine percent differences (table 2-2). Replicate estimates assumed to have identical water chemistry. Three replicate of recharge temperature differed by only 0.80 percent, samples of major and trace ions were collected (table 2-1). on average, with a maximum difference of 1.91 percent.
The average difference between analytical results of original Replicate samples of methane and oxygen differed by as much and replicate samples of major and trace ions was +/-1.9 percent as 53.3 and 46.1 percent, respectively, and differences may when all constituents were considered. The largest differences have been caused by bacterial consumption of oxygen. The were observed for the analyses of fluoride and uranium. The determinations of recharge temperature were likely unaf-difference between fluoride concentrations in original and fected because the two samples which indicated the largest replicate samples was +/-7.5 percent. The replicate sample from differences in methane and oxygen (C2 Canal at G-3608 well G-3610 indicated a -19.6 percent difference in uranium and well G-3607) indicated small differences in the recharge concentration from the original sample. The concentrations temperatures (1.39 and 0.19 percent, respectively).
of fluoride and uranium were low in the replicate and original Replicate samples were collected for all samples of samples for which large percentage differences were evalu- oxygen and hydrogen stable isotopes. Most of the replicate ated. The fluoride concentrations of these replicate samples samples were retained as potential replacement samples in ranged from 0.13 to 0.16 mg/L, and the reporting level for this case any of the original samples were lost during shipment to analysis was 0.08 mg/L. The amounts of uranium measured the laboratory for analysis. After results were received from in the original and replicate samples from well G-3610 were the original samples, thirteen of the replicate samples were 0.021 and 0.017 µg/L, respectively, and the reporting level for selected for analysis to evaluate the precision of the analytical this analysis was 0.008 µg/L. Excluding fluoride and uranium, method and the sampling procedures. The absolute value the analytical results of major and trace ions in original and of differences between the original and replicate samples replicate samples differed by +/-4.4 percent. analyzed for 2H ranged from 0.54 to 126 percent and aver-All of the samples collected to evaluate SF6, dissolved aged 26.0 percent. The absolute value of differences between gases, and 3H/3He age dating were collected in replicate. the original and replicate samples analyzed for 18O ranged Analytic results of the original and replicate samples of from 1.32 to 106 percent and averaged 18.9 percent. Although dissolved gases and SF6 are reported (tables 2-2 and 2-4), these differences seem large, when evaluted graphically except when a sample was lost or damaged during transport. (fig. 10-1) they do not greatly alter the interpretations that Replicates were collected for all dissolved gas samples, can be drawn from the analyses. For example, even though with the exception that the replicate sample from G-894 the differences between the original and replicate analyses of 4
C2 Canal 150 feet upstream of S-22, 9/14/2010 C2 Canal at G-3608, 9/15/2010 2
C2 Canal at G-3608, 7/28/2009 0 G-3608, 7/27/2009 G-3608, 9/15/2010 C2 Canal 150 feet Delta deuterium, per mil
-2 G-896, 09/21/2010 upstream of S-22, 08/3/2009 G-896, 08/04/2009
-4 G-3855, 8/18/2009 G-3607, 7/17/2009 G-3856, 8/18/2009
-6 G-1264, 10/27/2010
-8 EXPLANATION
-10 Original sample results G-3609, 7/30/2009 Replicate sample results
-12
-2.5 -2.0 -1.5 -1.0 -0.5 0 0.5 Delta oxygen-18, per mil Figure 10-1. Delta oxygen-18 and delta deuterium for samples and replicate samples, 2009-2010, Miami-Dade County, Florida.
100 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 2H and 18O in well G-3608 collected on July 27, 2009, were Fishman, M.J., ed., 1993, Methods of analysis by the U.S.
126 and 23.0 percent, respectively, the results still plot within Geological Survey National Water Quality Laboratory a small area as shown by the blue circles around each original Determination of inorganic and organic constituents in and replicate sample in figure 10-1. water and fluvial sediments: U.S. Geological Survey Open-To ensure that the deionized water used for equipment File Report 93-125, 217 p.
cleaning did not contain the major and trace ions evaluated during the study, quality-assurance samples of deionized Fishman, M.J., and Friedman, L.C., 1989, Methods for water were collected directly from the filtration system on determination of inorganic substances in water and fluvial July 16, 2009, and December 15, 2009, and analyzed for sediments: U.S. Geological Survey Techniques of Water-all ions of interest. No detections of any major or trace Resources Investigations, book 5, chap. A1, 545 p.
ions were above the minimum reporting levels for any of Garbarino, J.R., 1999, Methods of analysis by the U.S.
these ions. Geological Survey National Water Quality Laboratory To ensure that the equipment was properly Determination of dissolved arsenic, boron, lithium, sele-decontaminated between samples, 11 equipment blanks were nium, strontium, thallium, and vanadium using inductively collected using deionized water from the USGS National coupled plasma-mass spectrometry: U.S. Geological Survey Water Quality Laboratory. Minor amounts of iron ranging Open-File Report 99-093, 31 p.
from an estimated 2.3 to 8 µg/L were detected in 6 of the 11 equipment blanks, but because many of the well casings Garbarino, J.R., Kanagy, L.K., and Cree, M.E., 2006, Determi-were constructed of iron and the pump head was constructed nation of elements in natural-water, biota, sediment, and soil of stainless steel, this analyte was not considered for evalua- samples using collision/reaction cell inductively coupled tion of aquifer geochemistry. Excluding iron, one or more of plasma-mass spectrometry: U.S. Geological Survey Tech-the analytes evaluated for this study were detected in 4 of the niques and Methods, book 5, sec. B, chap. 1, 88 p.
11 blanks. The majority of these detections were below or very Katz, B.G., and Bullen, T.D., 1996, The combined use of close to the normal reporting level for the analytes detected.
87Sr/86Sr and carbon and water isotopes to study the Although calcium, chloride, magnesium, sodium, and hydrochemical interaction between groundwater and lake-strontium were detected in equipment blanks, the detections water in mantled karst: Geochimica et Cosmochimica Acta, were only 0.2 to 2.1 percent of the minimum concentrations
- v. 60, no. 24, p. 5075-5087.
measured in the groundwater and surface-water samples that were collected, and as such would not significantly affect Kohout, F.A., and Hoy, N.D., 1963, Some aspects of sampling the results of analyses. The one exception was the detection salty ground water in coastal aquifers: Ground Water, v. 1, of 22.8 µg/L of boron in the equipment blank collected at no. 1, p. 28-32.
C-5 Canal at NW 32 Court on August 6, 2010. The amount of boron in all other equipment blanks was less than the Ludin, A.I., Weppernig, Ralf, Bonisch, G., and Schlosser, reporting level of 4 µg/L. The boron concentrations in samples Peter, 1997, Mass spectrometric measurement of helium ranged from 27.2 to 2,470 µg/L. Boron averaged 245 µg/L in isotopes and tritium in water samples: Lamont-Doherty groundwater samples and 42.4 µg/L in surface-water samples. Earth Observatory of Columbia University, Technical Report 98.6, accessed May 12, 2011, at http://www.ldeo.
columbia.edu/~etg/ms_ms/Ludin_et_al_MS_Paper.html.
References Révész, Kinga, and Coplen, T.B., 2008a, Determination of the (2H/1H) of water: RSIL lab code 1574, chap. C1 of Révész, Kinga, and Coplen, T.B., eds., Methods of the Busenberg, Eurybiades, Plummer, L.N., Doughten, M.W.,
Reston Stable Isotope Laboratory: U.S. Geological Survey Widman, P.K., and Bartholomay, R.C., 2000, Chemical Techniques and Methods 10-C1, 27 p.
and isotopic composition and gas concentrations of ground water and surface water from selected sites at and near the Révész, Kinga, and Coplen, T.B., 2008b, Determination of Idaho National Engineering and Environmental Labora- the (180/160) of water: RSIL lab code 489, chap. C2 of tory, Idaho, 1994-97: U.S. Geological Survey Open-File Révész, Kinga, and Coplen, T.B., eds., Methods of the Report 00-81, 51 p. Reston Stable Isotope Laboratory: U.S. Geological Survey Techniques and Methods, 10-C2, 28 p.
Clesceri, L.S., Greenburg, A.E., and Eaton, A.D., eds., 1998, Standard methods for the examination of water and waste- Schlosser, Peter, Stute, Martin, Dorr, Helmut, Sonntag, water (20th ed.): Washington, D.C., American Public Health Christian, and Munnich, K.O., 1988, Tritium/3He dating of Association, American Water Works Association, and Water shallow groundwater: Earth and Planetary Science Letters, Environment Federation, p. 3-37 to 3-43. v. 89, p. 353-362.
Appendixes101 Schlosser, Peter, Stute, Martin, Sonntag, Christian, and Mun-nich, K.O., 1989, Tritiogenic 3He in shallow groundwater:
Appendix 11. Salinity Measurements Earth and Planetary Science Letters, v. 94, p. 245-256. in Canals U.S. Geological Survey, variously dated, National field man- Monthly measurements of salinity in canals collected ual for the collection of water-quality data: U.S. Geologi- by the Miami-Dade County Permitting, Environmental, cal Survey Techniques of Water-Resources Investigations, and Regulatory Affairs (M-D PERA); Maria Idia Macfar-book 9, chaps. A1-A9, available online at http://pubs.water. lane, Water and Sewer Department, written commun.,
usgs.gov/twri9A. March 7, 2011; Craig Grossenbacher, Miami-Dade County Permitting, Environmental, and Regulatory Affairs, written U.S. Geological Survey, 2011a, Reston Chlorofluorocar- commun., July 7, 2010) are provided as supplemental files.
bon LaboratorySF6 sampling: U.S. Geological Survey, accessed April 29, 2011, at http://water.usgs.gov/lab/sf6/ See supplemental file http://pubs.usgs.gov/sir/2014/5025/
sampling/. appendix/sir2014-5025_appendix_11.xlsx.
U.S. Geological Survey, 2011b, Reston Chlorofluorocarbon Laboratory Dissolved Gas N2 / Ar and 4He Sampling:
U.S. Geological Survey, accessed June 25, 2013, at http:// Appendix 12. Geographic Information water.usgs.gov/lab/dissolved-gas/sampling/.
System Files U.S. Geological Survey, 2011c, Reston Chlorofluorocarbon Laboratory3H/3He sampling: U.S. Geological Survey, GIS files for the 2008 and 2011 lines showing the inland accessed April 26, 2011, at http://water.usgs.gov/lab/3h3he/ extent of saltwater in the Biscayne aquifer are provided as sampling/. ESRI Arc-GIS shape files in separate electronic files. Metadata are included in these files. Users should view the Federal U.S. Geological Survey, 2011d, Reston Chlorofluorocarbon Geographic Data Committee (FGDC) metadata, because LaboratoryAnalytical procedures for SF6: U.S. Geologi- it provides important distribution information that other cal Survey, accessed April 26, 2011, at http://water.usgs. metadata formats do not include. These files describe the gov/lab/sf6/lab/analytical_procedures/. conditions of usage. The column LINETYPE in the attribute table should be used to indicate where the lines are shown as U.S. Geological Survey, 2011i, Reston Chlorofluorocarbon solid or dashed. To confirm that users are depicting this line LaboratoryAnalytical procedures for dissolved gasses correctly they should compare their maps to the USGS maps N2 / Ar: U.S. Geological Survey, accessed April 26, 2011, of these lines available at: http://www.envirobase.usgs.gov/
at http://water.usgs.gov/lab/dissolved-gas/lab/analytical_ FLIMS/SaltFront/viewer.htm (U.S. Geological Survey, 2011g).
procedures/.
See supplemental files in the folder http://pubs.usgs.gov/
sir/2014/5025/appendix/sir2014-5025_appendix_12.
Manuscript approved February 17, 2014 Prepared by the Raleigh Publishing Service Center Kimberly Waltenbaugh, Editor Kimberly Swidarski, Illustrations and layout For more information about this publication, contact:
Director U.S. Geological Survey Florida Water Science Center 4446 Pet Lane, Suite 108 Lutz, FL 33559 (813) 498-5000 or visit our website at http://fl.water.usgs.gov
Prinos and othersOrigins and Delineation of Saltwater Intrusion in the Biscayne AquiferScientific Investigations Report 2014-5025 ISSN 2328-0328 (online) http://dx.doi.org/10.3133/sir20145025
NRC-036 Submitted Nov. 10, 2015 Prepared in cooperation with Miami-Dade County Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater in Miami-Dade County, Florida Well field Sewage Cl/Br ratio = 300 to 800 Freshwater Biscayne Aquifer Limestone CaCO 3 Infiltration
+ + from tidal Quartz Sand SiO 2 Little or no ion exchange marshes seaward of the ion Freshwater exchange front inflow Freshwater/saltwater interface Ion exchange Leading edge front of saltwater Encroachment NaCl, B, Br, Leakage from front ete d from ocean K, Li, SO 4 D ep l Residual unprotected Mg along the base HC O 3 SO4 saltwater canals Ca Li K B
i ve of the aquifer va t Na o n ser Saltwater hed r=C E n r ic C l , B Pinecrest sand member Quartz sand SiO 2 Scientific Investigations Report 2014-5025 U.S. Department of the Interior U.S. Geological Survey
Cover. Conceptual diagram of sources and mechanisms of the saltwater that has intruded parts of aquifers in southeast Florida, and changes in water chemistry that may result from this intrusion.
Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater in Miami-Dade County, Florida By Scott T. Prinos, Michael A. Wacker, Kevin J. Cunningham, and David V. Fitterman Prepared in cooperation with Miami-Dade County Scientific Investigations Report 2014-5025 U.S. Department of the Interior U.S. Geological Survey
U.S. Department of the Interior SALLY JEWELL, Secretary U.S. Geological Survey Suzette M. Kimball, Acting Director U.S. Geological Survey, Reston, Virginia: 2014 For more information on the USGSthe Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment, visit http://www.usgs.gov or call 1-888-ASK-USGS.
For an overview of USGS information products, including maps, imagery, and publications, visit http://www.usgs.gov/pubprod To order this and other USGS information products, visit http://store.usgs.gov Any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government.
Although this information product, for the most part, is in the public domain, it also may contain copyrighted materials as noted in the text. Permission to reproduce copyrighted items must be secured from the copyright owner.
Suggested citation:
Prinos, S.T., Wacker, M.A., Cunningham, K.J., and Fitterman, D.V., 2014, Origins and delineation of saltwater intrusion in the Biscayne aquifer and changes in the distribution of saltwater in Miami-Dade County, Florida: U.S. Geological Survey Scientific Investigations Report 2014-5025, 101 p., http://dx.doi.org/10.3133/sir20145025.
ISSN 2328-0328 (online)
iii Acknowledgments The authors would like to acknowledge the contributions of information provided by EAS Engineering, Inc., the Florida Department of Environmental Protection, the Florida Keys Aqueduct Authority, Miami-Dade County Department of Environmental Resource Manage-ment, and the South Florida Water Management District. We greatly appreciate the cooperation of the following property owners who allowed us to make measurements on their lands: the AA Baker Group, LTD, the Archdiocese of Miami, Alamo Rent A Car, Barry University, FRS Hold-ings, Inc., the City of Homestead, Homestead Miami Speedway, Hallandale Beach Elementary School, the Miami-Dade County Department of Public Schools, Miami-Dade County Parks and Recreation Department, the South Florida Water Management District, and Palmer Trinity School. Bob Brown of the Archdiocese of Miami; Edward Swakon of EAS Engineering, Inc.;
Dr. Claudius Carnegie, Jorge Corrales, and Greg Mohr of the Miami-Dade County Department of Public Schools; Maria Idia Macfarlane, Sonia Villamil, and Virginia Walsh of the Miami-Dade Water and Sewer Department; and Steve Krupa of the South Florida Water Management District were instrumental in helping us gain access to numerous properties where the time-domain electromagnetic soundings were completed. Maria Idia Macfarlane of the Miami-Dade County Water and Sewer Department helped to oversee much of the well installation. Jorge Corrales helped collect many of the surface geophysical measurements that were made on lands owned by the Miami-Dade County Department of Public Schools. Michael J. Alexander, proj-ect manager of the Homestead Miami Speedway, not only provided necessary access to speed-way properties for measurements but also helped make necessary contacts with other properties owners in the area. Jim Happell of the University of Miami, Rosenstiel School of Marine and Atmospheric Science, John Stowell of Mount Sopris Instrument Company, and Roy Sonenshein of the National Park Service, Everglades National Park provided substantive reviews.
The authors also would like to acknowledge the contributions of staff members of the U.S. Geological Survey. Michele Markovits helped with many aspects of this study, including the geochemical sampling, geophysical data collection, data entry, and sample preparation and analysis. Adam Foster provided substantive geochemical advice and helped to compile sample results in the database. Robert Valderrama completed most of the processing of time series elec-tromagnetic induction log sets, and Brian Banks collected the most recent logs for these data-sets. Ronald Bruce Irvin provided quality assurance of these log sets and partially automated the application of necessary adjustments. Lee Massey and Corey Whittaker helped to collect water samples. Brian Banks, Adrian Castillo, Eric Carlson, and Jeff Robinson helped to collect time-domain electromagnetic soundings. Jeff Robinson also collected many of the borehole logs as the new monitoring wells were being installed and helped to oversee some of the well installation. Ronald Bruce Irvin created the necessary scripts, software, and files to convert the static Manual Water-Level Measurements in South Florida website into a dynamic website that serves routinely collected salinity information as well as most of the salinity information collected during this study. The new website has proven to be valuable to local water manag-ers as they seek greater understanding of the changes in the extent and magnitude of saltwater intrusion in the Biscayne aquifer. Ronald Bruce Irvin also oversaw quality assurance for the time-series electromagnetic induction logs used during this study. Michael W. Bradley, Ed Busenberg, Richard H. Coupe, Kim H. Haag, Steven Hinkle, Carole Johnson, Robert Renken, Dorothy Sifuentes, Rick M. Spechler, David Sumner, Kimberly A. Swidarski, Kim Walten-baugh, and Peggy Widman provided invaluable support during the review, approval, and publi-cation process of this report.
iv Contents Abstract............................................................................................................................................................1 Introduction.....................................................................................................................................................2 Definition of Terms.................................................................................................................................2 Purpose and Scope...............................................................................................................................6 Approach.................................................................................................................................................6 Description of Study Area....................................................................................................................6 Hydrologic Controls......................................................................................................................6 Topography and Physiography...................................................................................................7 Climate............................................................................................................................................7 Water Use in Miami-Dade County.............................................................................................7 Hydrogeology/Hydrostratigraphic Framework......................................................................10 Previous Studies..................................................................................................................................11 Origin of Saltwater Intrusion in Southeastern Florida............................................................................12 Mechanisms of Saltwater Intrusion.................................................................................................12 Upconing of Relict Saltwater from Previous Sea-Level High Stands................................12 Encroachment of Seawater along the Base of the Biscayne Aquifer...............................13 Infiltration of Saltwater from Saltwater Marshes.................................................................13 Seepage from Streams or Canals in which Saltwater has Migrated Inland....................13 Effects of Urban and Hydrologic Development on Saltwater Intrusion.....................................16 Predevelopment Conditions......................................................................................................17 Relation of Urban Development to Saltwater Intrusion.......................................................17 Data Collection and Analysis......................................................................................................................20 Salinity Measurements.......................................................................................................................21 Time-Series Electromagnetic Induction Logging...........................................................................21 Comparison of Bulk Resistivity to Specific Conductance of Water and Chloride Concentration.........................................................................................................................22 Time-Domain Electromagnetic Soundings......................................................................................22 HEM Survey Analysis..........................................................................................................................22 Approximate Inland Extent of Saltwater in the Biscayne Aquifer........................................................25 Improved Spatial Coverage and Precision of the Inland Extent of Saltwater...........................25 Changes between 1995 and 2011......................................................................................................25 Characterization and Distribution of Saltwater in the Biscayne Aquifer ...........................................28 Major and Trace Ion Geochemistry..................................................................................................28 Strontium Isotope Age Dating...........................................................................................................34 Oxygen and Hydrogen Stable Isotopes............................................................................................35 Tritium and Uranium Concentration..................................................................................................38 Tritium/Helium-3 Age Dating..............................................................................................................38 Sulfur Hexafluoride Age Dating.........................................................................................................39 Estimates of Recharge Temperature Based on Dissolved Gases...............................................39 Sources of Saltwater in the Biscayne Aquifer........................................................................................41 Relict Seawater from Previous Sea-Level High Stands................................................................41 Historical Leakage of Saltwater from Canals.................................................................................42 The Card Sound Road Canal and FEC Railway Borrow Ditches.........................................43
v Miami and Tamiami Canals.......................................................................................................47 C-111 Canal.................................................................................................................................47 Turkey Point Nuclear Power Plant Cooling Canal System...................................................47 Recent Leakage from Canals.............................................................................................................47 Card Sound Road Canal.............................................................................................................48 Biscayne Canal...........................................................................................................................48 Snapper Creek Canal.................................................................................................................49 Black Creek Canal......................................................................................................................51 Princeton Canal...........................................................................................................................54 Saltwater Encroachment....................................................................................................................55 Limitations......................................................................................................................................................56 Summary and Conclusions..........................................................................................................................64 Selected References....................................................................................................................................66 Appendix 1. Site Location and Construction Information.................................................................76 Appendix 2. Results of Geochemical Sampling..................................................................................76 Appendix 3. Salinity Profiles Collected from the Card Sound Road Canal....................................76 Appendix 4. Results of Time-Domain Electromagnetic Soundings.................................................76 Appendix 5. Time-Series Electromagnetic Induction Log (TSEMIL) Dataset Calibration and Processing.............................................................................................77 Appendix 6. Evaluation of Depth of the Biscayne Aquifer by Using TEM Soundings..................83 Appendix 7. Description of Installation and Construction of Saltwater Front Monitoring Wells...............................................................................................................88 Appendix 8. Geophysical Logs .............................................................................................................94 Appendix 9. Hydrostratigraphic Analysis............................................................................................94 Appendix 10. Geochemical Sampling Methods...................................................................................96 Appendix 11. Salinity Measurements in Canals ................................................................................101 Appendix 12. Geographic Information System Files..........................................................................101 Figures
- 1. Map showing the location of the study area, well fields, the National Parks, water conservation areas, and the helicopter electromagnetic survey of 2001, Miami-Dade and Broward Counties, Florida.............................................................................3
- 2. Map created for the Annual Report of the Surveyor General for 1859, New York, NY, General Land Office, 1859, courtesy of the Geography and Map Division of the Library of Congress.............................................................................................4
- 3. Map showing the physiographic provinces, location of the cross section shown in figure 7, and locations of rainfall monitoring stations within the study area.......................................................................................................................................8
- 4. Graph showing estimated total annual precipitation from selected stations in or near Miami-Dade County and documented droughts during 1931 to 2011.....................9
- 5. Graph showing estimated population (from U.S. Census Bureau, 2013) and public groundwater withdrawals in Miami-Dade County, Florida.........................................9
- 6. Chart showing the generalized relation of hydrogeologic, lithostratigraphic, and time-stratigraphic units in Miami-Dade County..............................................................10
- 7. Hydrogeologic section A-A showing hydrostratigraphy of the surficial aquifer system and uppermost part of the intermediate confining unit from west to east across central Miami-Dade County.................................................................................11
vi
- 8. Map showing the locations of salinity monitoring sites, time-domain electromagnetic soundings, groundwater-level monitoring wells, and the mapped approximations of the inland extent of saltwater in the Biscayne aquifer in Miami-Dade and southern Broward Counties......................................................15
- 9. Conceptual diagram of sources and mechanisms of the saltwater that has intruded parts of aquifers in southeast Florida, and changes in water chemistry that may result from this intrusion.........................................................................16
- 10. Graph showing salinity of the Biscayne Canal at station BS04, Miami-Dade County, Florida, 1988-2010..........................................................................................................17
- 11. Photograph showing the rapids of the Miami River prior to their destruction by dynamiting to increase drainage of the Everglades..............................................................19
- 12. Photograph showing the first water control structure on the Miami Canal installed in December 1939........................................................................................................19
- 13. Graph showing chloride concentration in samples from monitoring wells G-355, G-548, G-1351, and G-1354 near the Miami Canal and between 0.6 and 2.4 kilometers northwest of salinity control structure S-26, Miami-Dade County, Florida............................................................................................................................................20
- 14. Graph showing the relation between the resistivity of water samples collected in monitoring wells in Miami-Dade County, Florida, and the formation resistivity measured by electromagnetic induction logs in the screened intervals of the same well......................................................................................................................................23
- 15. Graph showing the relation between water resistivity and chloride concentration in water samples from monitoring wells in Miami-Dade County, Florida..........................23
- 16. Example of a depth slice from the 2001 helicopter electromagnetic survey, Miami-Dade County, Florida.......................................................................................................24
- 17. Map showing the origin and delineation of saltwater intrusion in the Biscayne aquifer and the basis for modifications to its mapped extent..............................................26
- 18. Graphs showing chloride concentrations in water samples from long-term monitoring wells...........................................................................................................................27
- 19. Graph showing the calcium to (bicarbonate + sulfate) ratio and the chloride concentration in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..................................................................................30
- 20. Graph showing the bromide and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................30
- 21. Graph showing the magnesium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida............................................................................................................................................31
- 22. Graph showing the potassium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................31
- 23. Graph showing the sodium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................32
- 24. Graph showing the boron and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................32
- 25. Graph showing the sulfate and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................33
vii
- 26. Graph showing the calcium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................33
- 27. Graph showing the barium and chloride concentrations in samples.................................34
- 28. Graph showing the silica and chloride concentrations in samples....................................35
- 29. Graphs showing relations between (A) chloride concentration and delta deuterium and (B) delta oxygen-18 and delta deuterium in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida..............................................................................................................................37
- 30. Graph showing the 3H/3He interpreted piston-flow ages of water samples collected during 2009-2010 in the Miami-Dade County area and dates of documented droughts in south Florida....................................................................................41
- 31. Graphs showing the (A) average monthly precipitation, daily average air temperature in Miami, Florida, and the range of recharge temperatures of water samples collected from the Biscayne aquifer in Miami-Dade County, Florida, and (B) average of daily maximum water levels in selected wells open to the Biscayne aquifer during October 1, 1974, to September 30, 2009..................44
- 32. Graphs showing (A) time-series electromagnetic induction log (TSEMIL) dataset and (B) chloride concentrations in samples from monitoring well G-3601 and bulk conductivity measured at a depth of 56.1 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................45
- 33. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3701 and bulk conductivity measured at a depth of 24.0 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................46
- 34. Graph showing salinity of the Snapper Creek Canal at station SP04, 1991-2010, Miami-Dade County, Florida..................................................................................49
- 35. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples collected from well G-3608 and bulk conductivity measured at a depth of 28.9 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................50
- 36. Graph showing chloride concentrations in water samples from wells G-896 and G-3608, Miami-Dade County, Florida................................................................................52
- 37. Graph showing water levels in wells G-896 and G-3608, 1996-2011, Miami-Dade County, Florida.......................................................................................................52
- 38. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from well G-3702 and bulk conductivity measured at a depth of 24.6 meters, Biscayne aquifer, Miami-Dade County, Florida.......................................................................................................53
- 39. Graph showing salinity of the Black Creek Canal at station BL03, 1991-2008 and 2010, Miami-Dade County, Florida.....................................................................................54
- 40. Graph showing salinity of the Princeton Canal at station PR03, 1991-2008 and 2010, Miami-Dade County, Florida.....................................................................................55
- 41. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3604 and bulk conductivity measured at a depth of 34.7 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................57
- 42. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3609 and bulk conductivity measured at a depth of 22.7 meters, Biscayne aquifer, Miami-Dade County, Florida......................................................................58
viii
- 43. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3698 and bulk conductivity measured at a depth of 24.5 meters, Biscayne aquifer, Miami-Dade County, Florida......................................................................59
- 44. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3699 and bulk conductivity measured at a depth of 25.3 meters, Biscayne aquifer, Miami-Dade County, Florida......................................................................60
- 45. Graphs showing: (A) time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3602 and bulk conductivity measured at a depth of 46.9 meters, Biscayne aquifer, Miami-Dade County, Florida........................................................................................61
- 46. Graphs showing time-series electromagnetic induction log (TSEMIL) datasets from monitoring wells (A) G-3855 and (B) G-3856 for November 2007 to April 2008, Biscayne aquifer, Miami-Dade County, Florida...................................................62
- 47. Graphs showing chloride concentrations in samples from monitoring wells, Miami-Dade County, Florida.......................................................................................................63
- 48. Graph showing salinity of the Mowry Canal at station MW04, 1991-2009 and 2010, Miami-Dade County, Florida.....................................................................................63 Tables
- 1. Partial history (1881-1978) of canal, structure, and levee installations in south Florida.................................................................................................................................18
- 2. Partial history (1899-2001) of well field installations and operations in Miami-Dade County, Florida.......................................................................................................19
- 3. Vertical flows measured in open boreholes prior to well installation, 2009-2011, Miami-Dade County, Florida..................................................................................21
- 4. Determination of the strontium-87 to strontium-86 ratio in water samples collected during 2009, in Miami-Dade County, Florida..........................................................36
- 5. Results of tritium/helium-3 age dating of water samples collected during 2009-2010 in Miami-Dade County, Florida...............................................................................40
- 6. Differences between ages determined using SF6 and tritium/helium-3 age dating for samples collected in Miami-Dade County, Florida, during 2009-2010.............42
- 7. Average recharge temperature and chloride concentration of surface-water and groundwater samples collected in Miami-Dade County, Florida during 2009-2010......................................................................................................................................43
ix Conversion Factors SI to Inch/Pound Multiply By To obtain Length centimeter (cm) 0.3937 inch (in.)
millimeter (mm) 0.03937 inch (in.)
meter (m) 3.281 foot (ft) kilometer (km) 0.6214 mile (mi)
Area square meter (m2) 0.0002471 acre square kilometer (km ) 2 247.1 acre square centimeter (cm2) 0.001076 square foot (ft2) square meter (m2) 10.76 square foot (ft2) square centimeter (cm2) 0.1550 square inch (ft2) square kilometer (km ) 2 0.3861 square mile (mi2)
Volume liter (L) 0.2642 gallon (gal) cubic meter (m )3 264.2 gallon (gal) cubic meter (m3) 0.0002642 million gallons (Mgal) cubic centimeter (cm ) 3 0.06102 cubic inch (in3) liter (L) 61.02 cubic inch (in3) cubic meter (m )3 35.31 cubic foot (ft3)
Flow rate meter per day (m/d) 3.281 foot per day (ft/d) meter per year (m/yr) 3.281 foot per year ft/yr) liter per second (L/s) 15.85 gallon per minute (gal/min) liter per minute (L/min) 0.2642 gallon per minute (gal/min) cubic meter per day (m3/d) 264.2 gallon per day (gal/d) cubic meter per second (m /s) 3 22.83 million gallons per day (Mgal/d)
Mass gram (g) 0.03527 ounce, avoirdupois (oz) kilogram (kg) 2.205 pound avoirdupois (lb)
Radioactivity becquerel per liter (Bq/L) 27.027 picocurie per liter (pCi/L)
Hydraulic conductivity meter per day (m/d) 3.281 foot per day (ft/d)
Hydraulic gradient meter per kilometer (m/km) 5.27983 foot per mile (ft/mi)
Transmissivity*
meter squared per day (m2/d) 10.76 foot squared per day (ft2/d)
x Electrical Conductivity and Electrical Resistivity Multiply By To obtain Electrical conductivity siemens per meter (S/m) 1,000 millisiemens per meter (mS/m) siemens per meter (S/m) 10,000 microsiemens per centimeter
(µS/cm)
Electrical resistivity ohm-meters (ohm-m) 0.001 kiloohm-meters (kohm-m)
Electrical conductivity in siemens per meter [S/m] can be converted to electrical resistivity in ohm-meters [ohm m] as follows: = 1/.
Electrical conductivity in millisiemens per meter [mS/m] can be converted to electrical resistivity in ohm-meters [ohm m] as follows: = 1,000/.
Electrical conductivity in microsiemens per centimeter [µS/cm] can be converted to electrical resistivity in ohm-meters [ohm m] as follows: = 10,000/.
Electrical resistivity in ohm-meters [ohm m] can be converted to electrical conductivity in siemens per meter [S/m] as follows: = 1/.
Electrical resistivity in ohm-meters [ohm m] can be converted to electrical conductivity in millisiemens per meter [mS/m] as follows: = 1,000/.
Electrical resistivity in ohm-meters [ohm m] can be converted to electrical conductivity in microsiemens per centimeter [µS/cm] as follows: = 10,000/.
Specific conductance (SC) refers to fluid electrical conductivity corrected to a temperature of 25 °C. The units of specific conductance are usually in microsiemens per centimeter [µS/cm].
The above conversions apply.
Temperature in degrees Celsius (°C) may be converted to degrees Fahrenheit (°F) as follows:
°F= (1.8x°C)+32 Temperature in degrees Fahrenheit (°F) may be converted to degrees Celsius (°C) as follows:
°C= (°F-32)/1.8 Vertical coordinate information is referenced to the National Geodetic Vertical Datum of 1929 (NGVD 29).
Horizontal coordinate information is referenced to the North American Datum of 1983 (NAD 83).
Altitude, as used in this report, refers to distance above the vertical datum.
- Transmissivity: The standard unit for transmissivity is cubic foot per day per square foot times foot of aquifer thickness [(ft3/d)/ft2]ft. In this report, the mathematically reduced form, foot squared per day (ft2/d) or meters squared per day (m2/d), is used for convenience.
Specific conductance is given in microsiemens per centimeter at 25 degrees Celsius
(µS/cm at 25 °C).
Concentrations of chemical constituents in water are given either in milligrams per liter (mg/L) or micrograms per liter (µg/L).
xi Abbreviations Ar Argon ABI Acoustic borehole image CCS Cooling canal system cc STP/g Cubic centimeters at standard temperature and pressure per gram cps Counts per second CU-LDEO Columbia University, Lamont-Doherty Earth Observatory Noble Gas laboratory EMI Electromagnetic induction ENSO El Nino-Southern Oscillation FEC Florida East Coast FEM Frequency-domain electromagnetic FGDC Federal Geographic Data Committee FKAA Florida Keys Aqueduct Authority FPL Florida Power and Light GIS Geographic information system GMWL Global meteoric water line GWSI USGS Ground Water Site Inventory system HEM Helicopter electromagnetic 3
H Tritium 2
H/1H Isotopic ratio of deuterium to hydrogen Hz Hertz kHz Kilohertz LEL Local evaporation line LSWML Local saltwater mixing line Ma Million years M-D DERM Miami-Dade County Department of Environmental Resource Management M-D PERA Miami-Dade County Permitting, Environmental, and Regulatory Affairs N2 Nitrogen N2/Ar Nitrogen/argon NOAA National Oceanic and Atmospheric Administration OBI Optical borehole image ORP Oxygen Reduction Potential 18 O/16O Isotopic ratio of oxygen-18 to oxygen-16 PDF Portable Document Format ppm parts per million ppt parts per thousand pptv parts per thousand total volume PSU Practical salinity units PVC Polyvinyl chloride Q Quaternary SF6 Sulfur hexafluoride SP Spontaneous potential SPR Single-point resistance SST Sea surface temperature TDS Total dissolved solids TEM Time-domain electromagnetic TSEMIL Time-series electromagnetic induction log USEPA U.S. Environmental Protection Agency USGS U.S. Geological Survey USGS-SI&T USGS Stable Isotope and Tritium USGS-RCL USGS Reston Chlorofluorocarbon Laboratory VSMOW Vienna Standard Mean Ocean Water WCA Water Conservation Area
Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater in Miami-Dade County, Florida By Scott T. Prinos, Michael A. Wacker, Kevin J. Cunningham, and David V. Fitterman Abstract supported by the similarity in the oxygen and hydrogen stable isotope composition in samples from the Snapper Creek Canal, Intrusion of saltwater into parts of the shallow karst 1.6 kilometers (km) inland of a salinity control structure, and Biscayne aquifer is a major concern for the 2.5 million residents in samples from well G-3608, which is adjacent to the canal, of Miami-Dade County that rely on this aquifer as their primary as well as by the relative ages of the water sampled from well drinking water supply. Saltwater intrusion of this aquifer began G-3608 and other wells open to the aquifer below the saltwater when the Everglades were drained to provide dry land for urban interface. Historical and recent salinity information from the development and agriculture. The reduction in water levels Card Sound Road Canal, monitoring well FKS8 located adjacent caused by this drainage, combined with periodic droughts, to the canal, and the 2001 helicopter electromagnetic survey allowed saltwater to flow inland along the base of the aquifer indicated that saltwater may occasionally leak from this canal as and to seep directly into the aquifer from the canals. The far inland as 15 km. This leakage may be prevented or reduced approximate inland extent of saltwater was last mapped in 1995. by a salinity control structure that was installed in May 2010.
An examination of the inland extent of saltwater and Saltwater also may have leaked from the Princeton Canal.
the sources of saltwater in the aquifer was completed during Results of geochemical sampling and analysis indicate 2008-2011 by using (1) all available salinity information, a close correspondence between droughts and saltwater (2) time-series electromagnetic induction log datasets from intrusion. Tritium/helium-3 apparent (piston-flow) ages deter-35 wells, (3) time-domain electromagnetic soundings collected mined from samples of saltwater with chloride concentrations at 79 locations, (4) a helicopter electromagnetic survey done of about 1,000 milligrams per liter (mg/L) or greater generally during 2001 that was processed, calibrated, and published corresponded to a period during which droughts were frequent.
during the study, (5) cores and geophysical logs collected Comparison of average daily air temperatures in Miami, from 8 sites for stratigraphic analysis, (6) 8 new water-quality Florida, with estimates of recharge temperatures determined monitoring wells, and (7) analyses of 69 geochemical samples. from the dissolved gas composition in water samples indicated The results of the study indicate that as of 2011 that saltwater likely entered the aquifer in April or early May approximately 1,200 square kilometers (km2) of the mainland when water levels are typically at their lowest during the year.
part of the Biscayne aquifer were intruded by saltwater. The Conversely, most of the samples of freshwater with chloride saltwater front was mapped farther inland than it was in concentrations less than about 1,000 mg/L indicate recharge 1995 in eight areas totaling about 24.1 km2. In many of these temperatures corresponding to air temperatures in mid to late areas, analyses indicated that saltwater had encroached along May when rainfall and water levels in the aquifer increase, and the base of the aquifer. The saltwater front was mapped closer the piston-flow ages of these samples correspond to wet years.
to the coast than it was in 1995 in four areas totaling approxi- The piston-flow ages of freshwater samples generally were mately 6.2 km2. The changes in the mapped extent of saltwater younger than ages of samples of saltwater.
resulted from improved spatial information, actual movement Saltwater samples that were depleted in boron, of the saltwater front, or a combination of both. magnesium, potassium, sodium, and sulfate, and enriched in Salinity monitoring in some of the canals in Miami-Dade calcium relative to the concentrations theoretically produced County between 1988 and 2010 indicated influxes of saltwater, by freshwater/seawater mixing, generally were found to with maximum salinities ranging from 1.4 to 32 practical be associated with areas where saltwater had recently salinity units (PSU) upstream of the salinity control structures. intruded. The calcium to (bicarbonate + sulfate) molar ratios Time-series electromagnetic induction log data from monitoring (Ca/(HCO3+SO4)) of these samples generally were greater wells G-3601, G-3608, and G-3701, located adjacent to the than 1. Saltwater samples from some of the monitoring wells, Biscayne, Snapper Creek, and Black Creek Canals, respectively, however, indicated little or no enrichment or depletion of these and upstream of the salinity control structures, indicated ions relative to the theoretical freshwater/seawater mixing line, shallow influxes of conductive water in the aquifer that likely and the Ca/(HCO3+SO4) molar ratios of these samples generally resulted from leakage of brackish water or saltwater from these were less than 1. Results indicated that aquifer materials are canals. The determination that saltwater influxes were recent is approaching equilibrium with seawater at these well locations.
2 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Introduction U.S. Geological Survey, 2011g). This website allows the USGS to deliver timely hydrologic data, analyses, and The Biscayne aquifer underlying the study area (fig. 1) decision-support tools concerning saltwater intrusion. The in Miami-Dade County and southern Broward County in results of this study, summarized in this report: (1) provide Florida is prone to saltwater intrusion because this area has needed information regarding the amount and quality of water low land-surface altitude and a low topographic gradient and in Miami-Dade County (2) advance the monitoring network is bordered to the east and south by sources of saltwater in the and techniques for determining water quality, and (3) advance Atlantic Ocean, Biscayne Bay, and Florida Bay. The aquifer understanding of the process of saltwater intrusion, which can is part of the surficial aquifer system, is semi-confined, and affect water availability.
consists primarily of highly permeable limestone. Prior to development, much of Miami-Dade County was covered by Definition of Terms the shallow marshes of the Everglades (fig. 2A). Beginning in the early 20th century to provide land for urban develop- The following definitions are used in this report:
ment, flood control, irrigation, and agriculture, a large part
- Brackish water - Water with chloride concentrations of the Everglades in this county was drained by a network of ranging from 251 to 1,000 milligrams per liter (mg/L).
uncontrolled or inadequately controlled canals (Leach and others, 1972, p. 23) that extended to the bays and the ocean.
- Freshwater - Water meeting the U.S. Environmen-This drainage and subsequent water-supply withdrawals tal Protection Agency (USEPA) secondary drinking reduced water levels in the aquifer. These water-level declines water standards for chloride concentrations less than were exacerbated during droughts and allowed saltwater to or equal to 250 mg/L (U.S. Environmental Protection intrude some water-supply wells and municipal well fields in Agency, 2011a).
Miami-Dade County.
In December 1939, the U.S. Geological Survey (USGS)
- Saltwater - Water having a chloride concentration began salinity and water-level monitoring in the Biscayne of greater than or equal to 1,000 mg/L. This value is aquifer. Shortly thereafter, water-resource managers began based on previous mapping efforts in southeast Florida implementing strategies to mitigate saltwater intrusion. The (Klein and Waller, 1985; Koszalka, 1995).
extent of saltwater intrusion was last mapped in 1995 (Sonen-
- Saltwater encroachment - A specific type of saltwater shein, 1997). Since 1995, salinity monitoring has indicated intrusion that is caused by the gradual lateral move-that saltwater has intruded farther inland in some locations and ment of saltwater from the sea inland along the base has receded seaward in others. At some locations, data were of the aquifer as a result of decreases of the freshwater insufficient to indicate the current extent of saltwater intrusion head in the aquifer relative to sea level.
or to determine whether changes had occurred. Furthermore, information on monitoring well construction indicated that
- Saltwater front - The farthest inland extent of saltwater some of the existing monitoring wells cannot provide the intrusion in the aquifer. In some instances there is quality of information necessary to fully evaluate movement brackish water from previous intrusion events or of the saltwater front in the Biscayne aquifer. residual connate water that occurs inland of the To address these concerns, the USGS, in cooperation saltwater front.
with Miami-Dade County, began a study in 2008 to:
delineate the current extent of saltwater intrusion in the
- Saltwater interface - A zone of transition between Biscayne aquifer; characterize how the extent has changed intruded saltwater and freshwater in the aquifer.
since the last mapping effort; improve salinity monitoring Sometimes this interface is sharp. Often this interface in the Biscayne aquifer; and identify the sources of the is diffuse and allows mixing between the two masses saltwater to better understand the actions required to prevent of water.
or mitigate saltwater intrusion. As part of this effort, eight
- Saltwater intrusion - A generic term referring to an new monitoring wells were installed in areas where there influx of saltwater through various pathways into was insufficient information to identify the location of the an aquifer.
front, and data from geophysical tools and techniques were incorporated into the analysis. To improve accessibility of
- Salinity - (1) A quantitative term describing the salinity monitoring information to the public, the USGS measured concentration of dissolved solids in water cooperative water conditions website was enhanced to allow expressed as practical salinity units (PSU) or in parts panning, zooming, and layer selections. The improved per thousand (ppt). (2) A generic term referring to vari-website, Saline Intrusion Monitoring, Miami-Dade County, ous types of information describing the concentration Florida, serves data collected during this study, as well as of dissolved solids in water. Information may include data from the active salinity monitoring network, and provides measurements of the electrical conductivity of water, the interpreted maps of the inland extent of saltwater intrusion airborne, borehole, or surface geophysical measure-(http://www.envirobase.usgs.gov/FLIMS/SaltFront/viewer.htm, ments, or sample results.
Introduction3 80°30' 80°20' 80°10' 820 "
L-33 HOLLYWOOD 26°00' A 7
L-67 C
67 95 75 L-BROWARD Snake Creek Ca COUNTY na l FLORIDA MIAMI-DADE 997 -9 )
W. E. Oeffler (C COUNTY 821 826 Biscayne Canal (C
-8)
Westside L-30 Northwest S-28 M 9 iam Hialeah Lake Okeechobee i
Preston MIAMI 25°50' Miami Springs Ft. Myers Upper " CaSPRINGS "
na Miami l Naples
- (C
-6 River Spring 195 "
Miami Springs S-26 ) Rapids Gardens Lower Florida Bay 836 Vaca Key
" Study MIAMI Key West Tamiami Canal (C-4) area Silver Bluff Coconut OCEAN Grove Alexander Orr COCONUT Snapper GROVE ATLANTIC Creek West Snapper Canal Southwest Creek (C-2) 25°40'
- Bay S-22 1 ne cay Florida Turnpike L-31N Bis Pri Naranja nce S-21 #
ton Park Canal (C-102)
Leisure Homestead M
owCity Airforce S-21A 25°30' Redavo ry Base Wittkop Park Cana l (C-103)
- S-20F HOMESTEAD " S-179 #
Florida City Newton Florida Keys Florida City Canal Aqueduct FLORIDA CITY Authority Everglades 1
Labor Camp MODEL LAND Ae FPL Cooling ro Modal Land Canal je Ca EXPLANATION Canal System t S (C-107) rd ou # Study area nd Canal (C-111)
R dR S-20 un Well fields So 25°20' rd al
- Ca d Can Water Conservation Area 3A S-18C oa u nd So Water Conservation Area 3B oa rd d
- S-197 Ca Biscayne National Park Everglades National Park 2001 Helicopter electromagnetic Bar Sou nes survey area nd S-20# Structure location and number Base from Miami-Dade County, South Florida Water Management 0 5 10 KILOMETERS and U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 0 5 10 MILES Figure 1. Location of the study area, well fields, the National Parks, water conservation areas, and the helicopter electromagnetic survey of 2001, Miami-Dade and Broward Counties, Florida.
4 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
µ 81°20' 81°00' 80°40' 80°20' 80°00' 27°00' 26°40' 26°20' B
26°00' 25°40' 25°20' 0 5 10 KILOMETERS 0 5 10 MILES Figure 2. (A) Map created for the Annual Report of the Surveyor General for 1859, New York, NY, General Land Office, 1859, courtesy of the Geography and Map Division of the Library of Congress.
Latitude and longitude grid georeferenced to the coordinate system of original map to the extent possible, given inaccuracies in original map. (B) Digital elevation map showing the topography of the study area in Miami-Dade County and southern Broward County. Altitudes are referenced to the National Geodetic Vertical Datum of 1929 (NGVD 29). Prior to conversion to meters, altitudes were initially referenced to the North American Vertical Datum of 1988 by the Florida Division of Emergency Management by using the results of a light detection and ranging (LIDAR) study (2009), and NGVD 29 altitudes were estimated with a +0.46-meter adjustment factor.
Introduction5 B
80°30' 80°20' 80°10' 26°00' BROWARD COUNTY MIAMI-DADE COUNTY 25°50' AN IC OCE ATLAN T
25°40' Bay EXPLANATION ayne Altitude Bisc High: 6.4 Meters Shelf edge 4.0 Meters 3.0 Meters 1.3 Meters 25°30' Low: Sea Level 0 2.5 5 KILOMETERS 0 2.5 5 MILES Base from U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 Figure 2. (A) Map created for the Annual Report of the Surveyor General for 1859, New York, NY, General Land Office, 1859, courtesy of the Geography and Map Division of the Library of Congress.
Latitude and longitude grid georeferenced to the coordinate system of original map to the extent possible, given inaccuracies in original map. (B) Digital elevation map showing the topography of the study area in Miami-Dade County and southern Broward County. Altitudes are referenced to the National Geodetic Vertical Datum of 1929 (NGVD 29). Prior to conversion to meters, altitudes were initially referenced to the North American Vertical Datum of 1988 by the Florida Division of Emergency Management by using the results of a light detection and ranging (LIDAR) study (2009), and NGVD 29 altitudes were estimated with a +0.46-meter adjustment factorContinued.
6 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Purpose and Scope monitoring wells installed as part of this study, as well as from several new wells that had been installed by other organiza-The purpose of this report is to document the methods tions. A preliminary map of the saltwater front was completed used to (1) delineate the current inland extent of saltwater in October 2008 using data available at that time. A final map intrusion, (2) examine the origins of saltwater intrusion, was completed in 2011 using the additional data collected and (3) describe the spatial and temporal changes in the during the study and made available from other organizations.
distribution of saltwater in the Biscayne aquifer in eastern Time-series water-quality and time-series electromagnetic Miami-Dade County. The analyses presented herein describe induction log (TSEMIL) datasets were used to evaluate the how saltwater from Biscayne Bay, Barnes Sound, Card changes that occurred in the location of the saltwater front Sound, Florida Bay, or the Atlantic Ocean (fig. 1) has been between 1995 and 2011 and to distinguish between changes in transported, and may continue to be transported within the the mapped location of the saltwater front resulting from front Biscayne aquifer. The study area extends westward from the movement and changes that likely resulted from improved coast as far as is required to describe saltwater in the Biscayne spatial monitoring network coverage.
aquifer from these sources. To identify the sources of salinity, water-quality samples This report includes discussions of the (1) extent of were collected for evaluation of the analytes alkalinity, saltwater intrusion, (2) environmental and anthropogenic barium, boron, bromide, calcium, chloride, fluoride, iron, causes of saltwater intrusion, (3) temporal and spatial changes magnesium, potassium, silica, sodium, strontium, sulfate, in the distribution of saltwater, (4) effects of urban and sulfur hexafluoride (SF6), uranium, tritium (3H); field proper-hydrologic development on saltwater intrusion, (5) types of ties including dissolved oxygen, pH, specific conductance, data collected, collection methods, and analytical methods, and and temperature; and the isotopic ratios of tritium and helium (6) limitations of this analysis. Geophysical data include time- (3H/3He ), oxygen (18O/16O), hydrogen and deuterium (2H/1H),
domain electromagnetic (TEM) soundings, a helicopter electro- and strontium (87Sr/86Sr). Selected sites were sampled to magnetic (HEM) survey, and electromagnetic induction (EMI) evaluate the apparent age of the water using 3H/3He and logs. A procedure developed during the study for interpretation SF6 age-dating methods. Selected samples were analyzed to of EMI log data is presented. TEM soundings also were used evaluate dissolved gas composition and terrigenic helium to evaluate the depth of the base of the Biscayne aquifer. This concentration. The analytes evaluated for each sample varied effort provided an evaluation of the quality of models devel- and were selected based on well construction, well installation oped from geophysical data and of the use of these models to date, sampling methods used, and study needs. The informa-augment existing stratigraphic information. Understanding the tion was interpreted to evaluate whether the saltwater sampled depth of the base of the Biscayne aquifer is important to this was relict or recent.
study because the toe of the wedged-shaped saltwater front typically extends farthest inland at the base of a given aquifer.
Description of Study Area Water chemistry analyses included determinations of dissolved gas concentrations, major and trace ion concentrations, stable The study area (fig. 1) is primarily the eastern part of isotope ratios, and tritium/helium-3 (3H/3He) age dating. These Miami-Dade County, Florida. The northern boundary is analyses were combined with time-series salinity data and in Hallandale Beach in southern Broward County, Florida geophysical information to evaluate the sources of saltwater (fig. 1). The southern boundary is the Florida Bay. Generally in the aquifer. Information on the construction of the eight the study area extends about 8 to 11 km (6 to 7 miles) inland new monitoring wells is included in the appendixes, including from the coast or Biscayne Bay. In the southern part of the borehole geophysical log data. Borehole geophysical data were county, however, the study area extends westward to the used to enhance the interpretation of the hydrogeology of the Aerojet (C-111) Canal.
Biscayne aquifer in Miami-Dade County. The procedures used to collect, model, and evaluate the TEM soundings collected for this study have been published separately (Fitterman Hydrologic Controls and Prinos, 2011). The calibration and interpretation of the 2001 HEM survey undertaken as part of this study are Saltwater intrusion is controlled by factors including presented in Fitterman and others (2012). (1) climatic conditions that result in wet and dry seasons, droughts, and floods; (2) the distribution of porosity within the sand and karst limestone layers of the Biscayne aquifer, (3) a Approach general eastward and southeastward groundwater-flow direc-tion, (4) freshwater levels in the aquifer relative to sea level, Water-quality data, including ongoing salinity and specific (5) generally low land-surface altitude (fig. 2B), (6) a low conductance monitoring data provided by various organiza- regional flow gradient, and (7) a water management system tions, and information from TEM soundings, EMI logs, and including drainage canals, water control structures, pumps, a HEM survey, were entered into a geographic information levees, water-supply well fields, and water conservation areas system (GIS). This information was used to construct a map of (fig. 1). High permeability surface materials or karst features the current saltwater front. Additional specific conductance and allow rapid recharge of the aquifer or surface sheet flow when chloride concentration samples were collected from the eight groundwater levels rise above the land surface.
Introduction7 Topography and Physiography Waller, 1985; Bridges and others, 1991, p. 231-238); 1980-82 (Waller, 1985; Bridges and others, 1991, p. 231-238); 1985 Miami-Dade County is generally flat and poorly drained. (South Florida Water Management District, 1985), 1989-90 The land-surface altitude for approximately 70 percent of the (Trimble and others, 1990), and 1998-2002 (Verdi and county is below 1.8 m. Figure 2A is a historical map showing others, 2006). Drought periods are shown on a graph of the predevelopment extent of the everglades. Areas shown average annual total rainfall during 1931 to 2011 (fig. 4). To as everglades in figure 2A correspond to areas that currently construct this graph, average monthly total rainfall at eight have land-surface altitudes of about 0 to 3.0 m (fig. 2B). East long-term monitoring stations was computed and totaled of the Everglades is the Atlantic Coastal Ridge physiographic annually. Selected stations had data that were 69 to 97 percent province (figs. 2B and 3), which ranges in altitude from 2.4 to complete for the evaluated period. The following National 7.3 m (Hoffmeister and others, 1967, p. 176; Lietz, 1999). East Oceanic and Atmospheric Administration, National Climatic and south of the Atlantic Coastal Ridge is the low lying (fig. 2B) Data Center stations were used: Everglades (1931-2011),
Coastal Marsh and Mangrove physiographic province (fig. 3). Fort Lauderdale (1931-2011), Hialeah (1941-2011),
Homestead Experimental Station (1931-1988), Miami Beach (1941-2011), Miami International Airport (1948-2011), Royal Climate Palm Ranger Station (1949-2011), and Tamiami Trail 40 Mile The wet and dry tropical climate (Hagemeyer, 2012) of Bend (1941-2006) (fig. 3). The 1998 to 2002 drought (fig. 4) south Florida is created by a combination of its latitude and was not as severe in Miami-Dade County as it was in other proximity to the ocean and the Gulf of Mexico. Although areas. During this period, the rainfall in Miami-Dade County Miami-Dade County is farther south than most of the United was lower than normal only in 2000, and the drought period States, buffering from the Atlantic Ocean ensures that summer was shorter (fig. 4) than in other parts of the State. Based on temperatures rarely exceed 38 °C, and winter temperatures the rainfall data, it appears that the 1985 and 1989-90 drought rarely fall below freezing. The highest and lowest tempera- periods were of longer duration in Miami-Dade County than tures typically occur during August and January, respectively. in other parts of the State and combined to form one extended Daily mean temperature averages about 28 °C in August drought period from 1984 to 1990 (fig. 4).
and 20 °C in January (National Climatic Data Center, 2012).
A wet season occurring from mid-May through September Water Use in Miami-Dade County of each year is typified by afternoon thunderstorms with relatively heavy rainfall that is augmented by rainfall from Miami-Dade Countys population of 2,496,000 (U.S. Census tropical storms and hurricanes. During the wet season, solar Bureau, 2010) makes Miami-Dade County one of the most radiation induces the movement of moist air inland from the populous counties in the United States. As of 2010, the ocean (Hagemeyer, 2012), where it combines with evaporating vast majority of the countys residents lived in an area of water from the swamps and wet prairies to produce frequent approximately 1,550 square kilometers (km2) that is within and generally localized thunderstorms. The low humidity and about 24 kilometers (km) of the ocean or Biscayne Bay. As solar radiation occurring during the dry season that extends the population of Miami-Dade County has increased, demand from October to early May greatly reduce the occurrence of for freshwater also has increased. The Biscayne aquifer is afternoon thunderstorms. Relatively low sea-surface tempera- the principal aquifer for the residents of Miami-Dade County tures during December to May also reduce the likelihood of (Miller, 1990). Ninety-nine percent of all groundwater tropical storms; consequently, rainfall during the dry season withdrawn in Miami-Dade County in 2005 emanated from is caused primarily by the interaction of cold fronts from the the Biscayne aquifer (Marella, 2009). Public groundwater north with moist tropical air in the south. withdrawals generally have increased as population increased The occurrence of hurricanes, tropical storms, and during 1965 to 1987 (fig. 5) (Marella, 1999, 2009; R.L.
droughts in south Florida is related to a large extent to the Marella, U.S. Geological Survey, written commun., 1998, El Nino-Southern Oscillation (ENSO). El Nino periods are 2011; U.S. Census Bureau, 2013). Although population characterized by unusually warm sea surface temperatures continued to increase at a relatively steady rate during 1993 to (SSTs) south of the equatorial eastern Pacific Ocean, whereas 2006, there was only a marginal increase in public ground-La Nina periods are characterized by unusually cool SSTs water withdrawals during this same period (fig. 5). Since 2006, in this region. El Nino periods tend to draw the jet stream public groundwater withdrawals have decreased as population southward, which produces wind shear that hampers the has continued to increase. This decrease may be, at least in formation of tropical storms and hurricanes but also increases part, the result of stricter water use restrictions that began in the likelihood of precipitation in south Florida. La Nina May 2007 when water levels in Lake Okeechobee declined to periods result in less precipitation and more persistent high record minimums. These water use restrictions were still in pressure systems in south Florida, which increases the poten- effect at the time of this report. The Biscayne aquifer is also tial for droughts (Hagemeyer, 2012). Prolonged droughts in the primary source of potable water for all residents living in Florida occurred in 1938-39 and 1943-46 (Parker and others, the Florida Keys, Monroe County (Marella, 2009). Water from 1955); 1949-57 (Waller, 1985; Bridges and others, 1991, the Biscayne aquifer is delivered by an aqueduct that extends
- p. 231-238); 1960-63 (Waller, 1985; Bridges and others, from the Florida Keys Aqueduct Authority (FKAA) well field 1991, p. 231-238); 1970-77 (Benson and Gardner, 1974; west of Florida City south to Key West (fig. 1). Although the
8 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 80°50' 80°40' 80°30' 80°20' 80°10' BROWARD COUNTY COLLIER COUNTY MIAMI-DADE COUNTY 75 27 1
826 95 821 25°50' " Hialeah Miami International " "
Tamiami Trail Airport 836 Miami 40 Mile Bend Beach
" 41 A' A
MONROE COUNTY AN IC OCE 25°40' Bay ATLAN MIAMI-DADE COUNTY T
ayne Bisc 1
Homestead Experimental Station 25°30' "
821 Royal Palm 9336 Ranger Station "
d un So rd 25°20' Ca 1
FLORIDA B
So arne un s d
Ft. Lauderdale Bay 25°10' Florida Everglades Base from U.S. Geological Survey digital data, 0 5 10 KILOMETERS EXPLANATION Universal Transverse Mercator projection, zone 17 PHYSIOGRAPHIC PROVINCES 0 5 10 MILES Atlantic Coastal Ridge Everglades Big Cypress Swamp Gulf or Bay Coastal Marsh and Sandy Flatwoods Mangrove A A' Cross section Hialeah Rainfall monitoring (see figure 7) station and site name Figure 3. Physiographic provinces, location of the cross section shown in figure 7, and locations of rainfall monitoring stations within the study area. Modified from Lietz (1999).
Introduction9 90 1938 1943 1949 1960 1970 1980 1984 2000 to to to to to to to 80 1939 1946 1957 1963 1977 1982 1990 Estimated total annual precipitation, in inches 70 60 50 40 30 20 10 0 1931 1933 1935 1937 1939 1941 1943 1945 1947 1949 1951 1953 1955 1957 1959 1961 1963 1965 1967 1969 1971 1973 1975 1977 1979 1981 1983 1985 1987 1989 1991 1993 1995 1997 1999 2001 2003 2005 2007 2009 2011 Year EXPLANATION 1985 Documented drought period and year(s)
Estimated average total annual precipitation for 1931-2011 Estimated total annual precipitation 3-year moving average (estimated total annual precipitation)
Figure 4. Estimated total annual precipitation from selected stations in or near Miami-Dade County and documented droughts during 1931 to 2011.
2,600,000 2,000 1,900 Public groundwater withdrawals, in million liters per day 2,400,000 1,800 1,700 2,200,000 1,600 1,500 Estimated population 2,000,000 1,400 1,300 1,800,000 1,200 1,100 1,600,000 1,000 1,400,000 900 800 EXPLANATION 700 1,200,000 Estimated population Water withdrawals 600 1,000,000 500 1960 1965 1970 1975 1980 1985 1990 1995 2000 2005 2010 Year Figure 5. Estimated population (from U.S. Census Bureau, 2013) and public groundwater withdrawals in Miami-Dade County, Florida.
10 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater spatial extent of the Biscayne aquifer is limited primarily to aquifer is wedge-shaped and becomes thinner toward the Broward, Miami-Dade, and Palm Beach Counties, it provided western part of Miami-Dade County (fig. 7). The deepest 33 percent of all public-supply groundwater used in Florida as part of the Biscayne aquifer is approximately 55 m deep in of 2005 (Marella, 2009). the northeastern part of the county (Fish and Stewart, 1991).
The depth of the base of the Biscayne aquifer in the area of the HEM survey in southern Miami-Dade County varies Hydrogeology/Hydrostratigraphic Framework from about 17 to 30 m (Fish and Stewart, 1991). Fish and The study area is underlain by the surficial aquifer Stewart (1991) show that the two aquifers merge with one system, the intermediate confining unit, and the Floridan another in central and northern coastal Miami-Dade County aquifer system (fig. 6). In the study area, the surficial (fig. 7). Both aquifers are composed mostly of highly porous, aquifer system corresponds with the Tamiami Formation karstic limestone, and the Biscayne aquifer is by far the more of Pliocene age; the Fort Thompson Formation, Key Largo productive of the two. Where the two aquifers are distinct, Limestone, Miami Limestone, and Pamlico Sand (Schroeder the top of the gray limestone aquifer is separated from the and Klein, 1954) of Pleistocene age, and the Lake Flirt Marl base of the Biscayne aquifer by an upper semiconfining unit of Holocene age (Parker and Cooke, 1944; Causaras, 1987; generally composed of quartz sands (figs. 6 and 7). The base Fish and Stewart, 1991; Cunningham and others, 1998; of the gray limestone aquifer is separated from the top of the Cunningham and others, 2001; Cunningham and others, 2004; underlying intermediate confining unit by a semiconfining unit Cunningham and others, 2006a, b). (figs. 6 and 7). In the study area (fig. 1), the surficial aquifer The surficial aquifer system includes two aquifers: the system generally has transmissivity values that are greater Biscayne aquifer and the deeper, informally named gray than 93,000 meters squared per day (m2/d) (1,000,000 feet limestone aquifer (Fish and Stewart, 1991). The Biscayne squared per day [ft2/d]) (Fish and Stewart, 1991). One aquifer Hydrogeologic Geologic Age 87Sr/86Sr Series unit unit (Ma) Ratio Lake Flirt Marl, Undifferentiated Holocene soil and sand 0.01 0.7091748 Pamlico Sand Biscayne Miami aquifer Surficial aquifer system Limestone Key Largo Pleistocene Fort Thompson Formation Formation 2.6 0.709068 Pinecrest Semiconfining Sand Tamiami Formation unit Member Gray Ochopee Limestone Pliocene limestone SI aquifer Member Fm Semiconfining unit 5.3 0.709027 Peace Intermediate River Hawthorn Group Confining unit Formation Miocene confining unit and Late Oligocene Arcadia Formation 28.1 0.708036 Floridan aquifer Suwannee Early Upper Limestone Oligocene Floridan 33.9 0.707827 system aquifer Ocala Late Limestone Eocene 37.8 0.707743 Avon Park Formation Middle Figure 6. Generalized relation of hydrogeologic, lithostratigraphic, and time-stratigraphic units in Miami-Dade County (based on Causaras, 1987; Fish and Stewart, 1991; Cunningham and others, 2001, 2006a; Reese and Richardson, 2008; Gradstein and others, 2012; and this report). [SI Fm, Stock Island Formation]
Introduction11 A A' MONROE COUNTY ATLANTIC MIAMI-DADE OCEAN COUNTY SEA LEVEL SEA LEVEL Biscayne aquifer Surficial Semiconfining unit aquifer system Gray limestone aquifer Semiconfining unit Intermediate confining unit Hawthorn Formation system Floridan aquifer VERTICAL SCALE GREATLY EXAGGERATED 0 5 10 KILOMETERS EXPLANATION Hydrostratigraphic boundary 0 5 10 MILES Lithostratigraphic boundary Figure 7. Hydrogeologic section A-A showing hydrostratigraphy of the surficial aquifer system and uppermost part of the intermediate confining unit from west to east across central Miami-Dade County (modified from Fish and Stewart, 1991). Location of cross section shown in figure 3.
test in central Miami-Dade County indicated a transmissivity Previous Studies of 270,000 m2/d (Fish and Stewart, 1991).
The intermediate confining unit underlies the surficial The mechanisms of saltwater intrusion and the changes aquifer system (figs. 6 and 7). The intermediate confining unit in the hydrology of south Florida that allowed saltwater to is approximately 170 to 240 m thick and is composed of a intrude large parts of the Biscayne aquifer in Miami-Dade succession of quartz sand and sandstone, limestone, dolomite, County have been described by Cross and Love (1942),
and minor terrigenous mudstone, diatomaceous mudstone, Parker (1945), Parker and others (1955), Kohout and Leach and dolosilt that compose the Late Oligocene-Early Pliocene (1964), and Renken and others (2005a). Brown and Parker Hawthorn Group (Fish and Stewart, 1991; Cunningham and (1945) provided detailed examinations and a cross section others, 2001). In the study area, the intermediate confining showing saltwater encroached at Silver Bluff in Coconut unit overlies the Upper Floridan aquifer of the Floridan aquifer Grove (fig. 1). Hoy and others (1951) published six cross system (fig. 6), which is composed primarily of limestone sections showing changes in the position of the saltwater and relatively minor dolomitic limestone and dolomite front in the Miami area between 1946 and 1950. Klein (Reese, 1994). The intermediate confining unit also can (1957) provided a contour map of the saltwater front near include the lowermost part of the Tamiami Formation (Fish Silver Bluff in Coconut Grove (fig. 1). Schroeder and others and Stewart, 1991) and the Stock Island Formation. (1958) described the Biscayne aquifer in Dade (currently
12 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater named Miami-Dade) and Broward Counties and reported Prinos and others (2002) examined the chloride that, at that time in southern Broward County near the city concentrations in USGS monitoring wells during of Hollywood, saltwater had not yet encroached as far inland 1974-1999 in the Biscayne aquifer and identified statistically as U.S. Highway 1, which is about 2.4 km from the ocean. significant increasing trends in chloride concentrations in the Sherwood and Leach (1962) found that the Biscayne aquifer data from 40 percent of the wells in this aquifer. Decreasing in the vicinity of salinity control structure S-22 on the trends in chloride concentrations were identified in the data Snapper Creek Canal (fig. 1) is so permeable that if water from 28 percent of these wells. Data from 32 percent of levels upstream of the structure are higher than water levels the monitoring wells showed no quantifiable trend for the downstream of the structure, then when the structure is closed, period evaluated.
water will flow through the aquifer under the structure toward Biscayne Bay.
Sherwood and Klein (1963) evaluated the relation between surface water and groundwater in southeastern Origin of Saltwater Intrusion in Florida and provided a comparison of the water levels in Southeastern Florida Miami-Dade County near Miami with the inland extent of saltwater in the Biscayne aquifer. The relation of saltwater An understanding of the mechanisms of saltwater intrusion to discharge in the Miami River and its tributaries intrusion and the effects of urban development in southeast was evaluated by Leach and Grantham (1966). This analysis Florida is necessary for water management and development indicated that water with a chloride concentration of of remediation strategies. The management and remediation 1,000 parts per million (ppm) occurred in the Miami Canal as strategies necessary to prevent saltwater from encroaching far inland as control structure S-26 (fig. 1) about 23 percent of inland along the base of the aquifer are different from those the time and that about 60 percent of the Biscayne aquifer in needed to prevent saltwater from leaking upward from the vicinity of the Miami Canal and its tributaries could gradu- deeper aquifers. Mitigation of saltwater intrusion, while also ally be restored to freshwater conditions if the structure were addressing the frequently competing needs of flood preven-moved downstream of the confluence of the Tamiami Canal. tion, agriculture, urban development, public water supply, Kohout and Leach (1964) examined the relation between and ecosystem preservation, has resulted in a complex water water control dam operation in the Snake Creek Canal and management system of canals and water control structures salinity in the aquifer. Bearden (1974, p. 25) mapped the (fig. 8) as well as an extensive saltwater monitoring network.
potentiometric surface in southern Broward County near the city of Hollywood and provided maps showing the extent of saltwater intrusion occurring near unregulated canals. Mechanisms of Saltwater Intrusion The USGS mapped the approximate inland extent of A number of mechanisms have led to the occurrence of saltwater in the Biscayne aquifer in Miami-Dade County in saltwater in the Biscayne aquifer (fig. 9). These mechanisms 1951 (Hoy, 1952), 1978 (Swayze, 1980), 1984 (Klein and include (1) upconing of relict or residual saltwater that had Waller, 1985), and 1995 (Sonenshein, 1997) and in Broward been incorporated in relatively impermeable sediments during County in 1990 (Koszalka, 1995). Parker and others (1955) previous sea-level high stands occurring during interglacial also published a map showing the inland extent of saltwater in periods (Parker, 1945, p. 533; Bearden, 1974, p. 25), (2) the the Biscayne aquifer in Miami-Dade County that differs from gradual encroachment of saltwater from the ocean along the the map created in 1951 (Hoy, 1952), but the date that this base of the aquifer resulting from reductions in freshwater map was created is not provided.
head relative to sea level (Cross and Love, 1942, p. 501),
Klein and Ratzlaff (1989) and Sonenshein and Koszalka (3) infiltration of saltwater from coastal saltwater mangrove (1996) evaluated changes in the extent of saltwater intrusion marshes (Matson and Sanford, 1913, p. 59), and (4) the flow in the Biscayne aquifer in Miami-Dade County. Prior to the of saltwater inland through canals where it leaks into the current study, little groundwater salinity information was aquifer (Cross and Love, 1942, p. 501).
available for the area south of Florida City in southeastern Miami-Dade County; therefore, the line in the map showing the inland extent of saltwater in the Biscayne aquifer plotted Upconing of Relict Saltwater from Previous by Sonenshein (1997) was dashed in this area to indicate Sea-Level High Stands that data were insufficient. Sonenshein (1997) used the interpretations of 15 TEM soundings to augment the informa- During the Pleistocene, sea levels varied as water tion provided by monitoring wells; the majority of these was periodically stored or released by growing or melting soundings were collected near the Miami Canal. Fitterman continental ice sheets. The sand and limestone formations and Deszcz-Pan (1998, 2002) and Fitterman and others (1999) of the Biscayne aquifer consist largely of materials that interpreted TEM soundings and HEM surveys to evaluate were deposited while shallow seas covered south Florida.
saltwater intrusion in southwestern Miami-Dade County in the These materials, when first deposited, would have included Everglades National Park. connate saltwater in the pore fluids. As sea level declined,
Origin of Saltwater Intrusion in Southeastern Florida 13 saline pore fluids generally were replaced by freshwater Infiltration of Saltwater from Saltwater Marshes that flowed through the aquifer. Some of the less permeable materials, however, may have retained some of the relict Infiltration of saltwater from saltwater marshes occurs saltwater. This source of saltwater was discussed by Parker along the southern, southwestern, and southeastern coastlines and others (1955). It is also possible that some strata were of Florida, where the land surface is so low that saltwater intruded again by seawater as sea level rose during later can flow over land for approximately 1 to 3 km at high tide.
interglacial periods. The water in these saltwater marshes can become hypersaline as a result of high evaporation rates, and during droughts, reductions in freshwater levels and flows may allow the Encroachment of Seawater along the Base of saltwater in these marshes to migrate inland. Tropical storm the Biscayne Aquifer or hurricane-driven storm surge or gale-driven seiches may cause the saltwater to flow farther inland than normal, where The encroachment of seawater along the base of the it could infiltrate the aquifer. Reductions in freshwater levels Biscayne aquifer can be described by the Ghyben-Herzberg in the Everglades likely increased the potential for overland relation (Ghyben, 1889; Herzberg, 1901), applied by Brown flow of this saltwater. Installation of canals also provided a (1925, p. 17) to coastal aquifers:
pathway for inland flow of this saltwater. Meyer (1974, p. 28) reported that on the upstream side of water control structure t S-18C (fig. 8) in September 1965 the chloride peaked at h= , (1) g 1 13,370 mg/L as a result of tidal inundation during Hurricane Betsy. S-18C is 9.8 km inland from Florida Bay. Meyer (1974) also reported that the chloride concentration of the where h is the depth of saltwater below sea level, g is the water was 10,000 mg/L at least 3.2 km farther upstream specific gravity of seawater, t is the height of freshwater above from S-18C.
sea level, and the specific gravity of the freshwater is assumed to be 1. This relation describes saltwater encroachment in a homogeneous, unconfined aquifer under hydrostatic condi- Seepage from Streams or Canals in which tions. Although the Biscayne aquifer is not homogeneous Saltwater has Migrated Inland and flow conditions are not hydrostatic, this relation can be used to derive a coarse approximation of the freshwater Parker and others (1955, p. 621) described the potential head necessary to prevent saltwater intrusion in the Biscayne migration of saltwater up canals in terms of a balance of aquifer. Given a specific gravity of 1.0268 for seawater in the seawater and freshwater heads. Well-designed salinity Miami area (Parker and others, 1955, p. 573), the interface control structures can potentially reduce or prevent saltwater between fresh and saltwater in the aquifer will be depressed encroachment along the base of the aquifer and the seepage by approximately 37.3 m for each meter of freshwater head of saltwater from canals by retaining sufficient freshwater above sea level. The Ghyben-Herzberg relation indicates that in the canal to increase the hydraulic head in the canals and the altitude of freshwater must be 0.6 to 1.5 m above sea level in the aquifer adjacent to canals and by directly preventing to prevent encroachment of saltwater along the base of the the flow of saltwater upstream. Salinity control structures in aquifer because the base of the Biscayne aquifer ranges from Miami-Dade County, however, have not always prevented 24 to 55 m below land surface near the east coast of Miami- saltwater intrusion. The extensive secondary porosity of layers Dade County (Fish and Stewart, 1991). Altitudes of freshwater within the Biscayne aquifer potentially can allow saltwater in some areas of coastal Miami-Dade County are well below flow around the structures through the aquifer (Leach and these altitudes (U.S. Geological Survey, 2011f); consequently, Grantham, 1966, p. 25) unless grout walls or other such some saltwater encroachment has occurred. features were installed to prevent this flow. Between 1988 and The full extent of encroachment predicted by the 2010 there have been, for example, frequent influxes of Ghyben-Herzberg relation does not occur in some parts of water, with a salinity of between 15 and 32 PSU at station the Biscayne aquifer because the relation describes a static BS04 (Maria Idia Macfarlane, Water and Sewer Department, balance of densities, rather than the dynamic forces actually written commun., March 7, 2011; Craig Grossenbacher, occurring within the aquifer (Kohout, 1964). The direction of Miami-Dade County Permitting, Environmental, and Regula-fresh groundwater flow in the Biscayne aquifer is typically tory Affairs, written commun., July 7, 2010) in the Biscayne from inland toward the coast, and the gradient increases Canal (fig. 10), which is upstream of the salinity control during periods of recharge. Kohout (1964) determined that structure S-28 (fig. 8).
saltwater (1) tends to flow inland along the base of the aquifer, In the Snake Creek Canal, when the salinity control (2) becomes less dense and flows upward as it mixes with structure was open, water from the shallow aquifer drained freshwater at the freshwater-saltwater interface, and then toward the canal, the saltwater front at the base of the (3) flows back toward the sea along with the freshwater Biscayne aquifer moved inland, and leakage of saltwater flowing seaward. from the canal into the aquifer was reduced or eliminated
80°30' 80°20' 80°10' MIA242 ! G-2956 G-2477 FLORIDA 7 MIA239 G-2478 26°00' MIA240 G-2410 MIA237 J" J"
J G-2409 MIA238 "
J!!!! G-1435 27 MIA241 G-2294 MIA115 " !
J G-2965 G-2903 MIA135 "
J 75 Snake Creek Canal G-3949 "
J MIA114 Lake Okeechobee (C
BROWARD COUNTY # -9)
S-30 C9 Canal MIAMI-DADE near NE 17 Ave G-3705 G-3600 COUNTY S-32#
- S-31 !!
S-32A 821 MIA131 ""
J MIA130 J ! # Study 997 826 MIA113 " !
Canal (C- J Key West area Biscayne 8) G-3948 J
95 MIA112 G-894 # G-58 G-3601 ! !
C8 Canal at G-3601 Arch MIA124 ! F-279 Creek MIA122 " J" BS04 MIA123 J
- G-72 #
M Little River Canal (C-7) G-3224 S-28 EXPLANATION iam iC G-3602 Approximate inland extent of saltwater an ! !
al 1955 (C 9 MIA133 LR06 # S-27
-6
) MIA134 1995 MIA132 !"J 2011 Miami Canal G-3947 25°50' ! at Water Plant "
J J
F-45 Lines are dashed where information G-3250 !
G-355 G-3603 ! was insufficient for an accurate G-548 ! G-1354 S-26 1 estimate G-571 ! ! ! 195 G-354 ! # !
J J G-3704 "
J Time-domain electromagnetic soundings G-1351 MIA121 Comfort MIA120
- S-25B ! U.S. Geological Survey groundwater-Canal (C-5) ! G-3604 S-25 395 level monitoring well 836 J# S-338 #
MIA119 Water-control or salinity-control S-335 # S-25A MIA117 " "
J J! MIA118 Miami C5 Canal MIA116 G-3605 River structure Tamiami Canal (C-4) Cor at NW 32 Ct S-336 G-119 al G-3888 !
- # S-24 # 41 Salinity monitoring sites by organization S-334 G-3229 ! ! Florida Keys Aqueduct Authority Gables 972 G-93 OCEAN Ca na 1 EAS Engineering, Inc.
l (C-3)#
G-432 Bay MIA107 " U.S. Geological Survey J ! ! yne !
G-3606 Miami-Dade County Permitting, S-24A # Bis Environmental, and Regulatory ca ATLANTIC Affairs Sn ap G-3607 G-901 per Cr !
J eek Canal J" (C-100)
MIA126 " MIA125 S-121 14 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 94 # C2 Canal 150ft G-1009B ! !!
G-896 C2 Canal upstream of S-22 G-3608 at G-3608 MIA105 MIA106 "J" J!
- G-3609 !# ! SP04 25°40' Cutler S-120 Can G-211 S-22 0C
- S-338 "
J MIA127 "
J alC-1 ! G-3887 Canal C100A Canal C-10 Dr MIA128 00A at SW 72 Ave a in S-119
- ! ! G-3313C Ca nal !
G-3313E B G-3610 el-Ai #S-118 G-3611
S-331 ! G-939 G-114 # CD02 !
- nal #S-123 S-173 Bla ire C a J MIA108 " MIA109 J MIA110 S-182A "
J S-122 MIA129 " MIA111 re !
ck C J!
S-194 ek MIA129 Princ S-149 821
- eto Ca n G-3886 !
n al G-3612 Ca (C
-1 nal )
- Florida City S-148 G-3702 Canal at G-3699 C1 Canal !
G-3699 at G-3702
- BL03 Florida City Canal MIA101 !
G-3885 ! ! !!
997 "
J " J J S-165 # G-3701 GL03 S-21
- MIA104 " J MIA102
! ! G-3855 (COH-MW-trig-BS)
Goulds Canal G-3856 MIA103 (COH-MW-Sen)
! G-3162 !
S-166 MIA136 "
J PR03 S-21A FKS 9 S-196 J !! # Sec34-MW-02-FS
- Mow ry MIA137
! G-3700 ! G-3615 Canal 102 at
! SW 107 Ave S-196A S-167 !
25°30'
- near Sec34-MW-01-FS !! "
J MIA202 G-1180 ! G-1179 Homestead, FL G-3938 "
J "
J MI03 1 MIA203 TENNESSEE ROAD
! # MIA201 Military Canal 1 Can S-179 S-20G al (C-103) MW04 !
! Sec34-MW-03-FS
- ! ! S-20F# G-1264 Canal at G-3698 G-3698 FPL Turkey MIA225 G-3164 997 North Canal "! !
Point " MIA207 J "
J MIA206 "
J MIA204
! G-3936 J CEMEX-MW-03-FS G-3937 Nuclear !
! ACI-MW-15-BS J J" J! Power Plant MIA205 J Florida City Canal
! MIA208 " "
J MIA226 J ACI-MW-16-BS J MIA215 J "
J "
J J MIA209 MIA227 "
J MIA210 MIA230 J! ! "
J "
J ! "
J "
J J! "
J! "
J # !
J ""
J J G-3166 G-3939 "
J MIA214 MIA229 J "
J" S-178 ! "
J! "
J! "J "
J "
J ! G-3946 J
J J J "J" "
J 31 E G-613 # FPL Cooling MIA211 "
J " J MIA213F J MIA228 J
al L Canal System "
J Can "
J MIA212F J MIA233F SW 137 AVENUE MIA224 MIA236 MIA216 MIA232 "
J "
J " J "
J J" J Card Sound Road Canal FKS 5 MIA217 "
J MIA235F FKS 4 MIA223 MIA234 7.7 mi upstream from mouth "
J G-3940 G-3342 MIA221 S-20 !
J "
J " J # FKS 8 MIA231
! FKS 6 FKS 7 "
J MIA219F MIA222 MIA220 G-3167
! FKS 3 S-18C FKS 2 (plugged) al 25°20' ! ! "
an
- G-1256 J MIA218 dC FKS 1 d R oa OAD G-1603 1 un DR rd So OUN d un Canal C-110 Aer ojet a Ca RD S So Can FEC R CA rd Ca Canal C-109 al (C MO
-111
)
ilway CO NRO UN E
- TY S-197 Borrow Bar Ditch Sou nes nd Base from Miami-Dade County, South Florida Water Management 0 2.5 5 KILOMETERS and U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 0 2.5 5 MILES Figure 8. Locations of salinity monitoring sites, time-domain electromagnetic soundings, groundwater-level monitoring wells, and the mapped approximations of the inland extent of saltwater in the Biscayne aquifer in Miami-Dade and southern Broward Counties in 1955, 1995, and 2011. Enlarged version of this figure availabe for download at http://pubs.usgs.gov/sir/2014/5025/downloads/sir2014-5025_figure08large.pdf.
Origin of Saltwater Intrusion in Southeastern Florida 15
16 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Well field Sewage Cl/Br ratio = 300 to 800 Freshwater Biscayne Aquifer Limestone CaCO 3 Infiltration
+ + from tidal Quartz Sand SiO 2 Little or no ion exchange marshes seaward of the ion Freshwater exchange front inflow Freshwater/saltwater interface Ion exchange Leading edge front of saltwater Encroachment NaCl, B, Br, Leakage from front le t e d from ocean K, Li, SO 4 Dep Residual unprotected Mg along the base O4 HC O BS 3
saltwater canals Ca K e of the aquifer Li ativ ed Na
=C o n s er v Saltwater i ch C l , B r E nr Pinecrest sand member Quartz sand SiO 2 Figure 9. Conceptual diagram of sources and mechanisms of the saltwater that has intruded parts of aquifers in southeast Florida, and changes in water chemistry that may result from this intrusion.
because the flow gradient in the aquifer was primarily Effects of Urban and Hydrologic Development on toward the canal (Kohout and Leach, 1964, p. 36).
Saltwater Intrusion Conversely, when the water control structure was closed, the water that was in the canal inland of the dam, whether A goal of this study was to examine the environmental it was fresh or saline, was pushed horizontally outward into and anthropogenic causes of saltwater intrusion in the the aquifer. The potential exists, therefore, for intrusion of Biscayne aquifer in eastern Miami-Dade County and to the aquifer caused by any saltwater trapped upstream of delineate the resulting distribution of saltwater of various control structures. ages and sources. This goal was accomplished in part through The National Oceanic and Atmospheric Administration geochemical evaluations of recharge conditions and ages of (NOAA) estimates that mean sea levels at Ft. Myers, Key water in the aquifer. A detailed understanding of the history West, Miami Beach, Naples, and Vaca Key, Florida, have of saltwater intrusion provides a valuable framework for increased at rates of 0.24, 0.22, 0.24, 0.20, and 0.28 m per evaluating these geochemical results. The following sections 100 years, respectively (National Oceanic and Atmospheric provide a summary of predevelopment conditions and Administration, 2012). Relative increases in sea level may events leading to saltwater intrusion in the Biscayne aquifer.
exacerbate the encroachment of saltwater along the base of Detailed examinations of the history of urban and hydrologic the aquifer and the leakage of saltwater past salinity control development in the study area are provided by Fletcher (1911),
structures where it could potentially leak into the aquifer. Paige (1986), and Parker and others (1955).
Origin of Saltwater Intrusion in Southeastern Florida 17 35 30 25 Salinity, in practical salinity units 20 15 10 5
0 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 10. Salinity of the Biscayne Canal at station BS04, Miami-Dade County, Florida, 1988-2010.
Predevelopment Conditions at least some saltwater intrusion in this area, which may have been caused by inland flow of saltwater in coastal streams or Prior to development, the freshwater marshes of the overwashing of the coast during hurricanes or tropical storms.
Everglades covered approximately 3,000 km2 of Miami-Dade County, which is most of the land west of the Atlantic Coastal Ridge except for an area in northwestern Miami-Dade Relation of Urban Development to Saltwater County (figs. 2A and 3). Most of the southern and eastern Intrusion coastal parts of the county, approximately 1,030 km2, were covered with coastal marshes and mangrove swamps (fig. 3). Water levels in the Biscayne aquifer near Miami are Water levels in the Everglades near Miami are estimated estimated to be approximately 2.9 m below predrainage conditions based on a comparison of historical information to have been approximately 3 to 4.3 m above NGVD 29 and monitoring-well data (Parker and others, 1955, p. 580; (Shaler, 1890, p. 158; Parker and others, 1955, p. 581; Fish U.S. Geological Survey, 2011f), and this reduction in water and Stewart, 1991, p. 47). These water levels exceed the levels has resulted in saltwater intrusion in about 1,200 km2 of estimated minimum freshwater heads (0.6 to 1.5 m) necessary the Biscayne aquifer in Miami-Dade County as of 2011. The to prevent saltwater encroachment in the Biscayne aquifer. events that led to this intrusion began in December 1845 when Early residents and visitors describe numerous freshwater drainage of the Everglades was first proposed by the Florida springs, onshore near the coast as well as offshore in Biscayne State Senate (Paige, 1986, p. 138). Between 1850 and 1907, Bay (Fuller, 1904; Munroe and Gilpin, 1930; Parks, 1987). various Federal and State acts were passed to facilitate Water levels were sufficiently high prior to development in drainage of the Everglades, and these acts provided authority this area to maintain freshwater in the Biscayne aquifer close and resources for the installation of numerous drainage canals.
to the coast (Parker, 1945). Although the current study did The Miami Canal (table 1; fig. 11) installed beginning in 1908, not identify any historical information directly describing was one of the first canals in south Florida. Concrete locks and the extent of saltwater intrusion in the southernmost parts of dams that might have helped reduce saltwater intrusion were Miami-Dade County prior to drainage of the Everglades, the installed in 1912-13 in many of the canals; however, with a low land-surface altitudes in this area and the existence of few exceptions, these locks and dams typically were poorly coastal saltwater marshes indicate that there may have been maintained and operated (Parker and others, 1955, p. 587).
18 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 1. Partial history (1881-1978) of canal, structure, and levee installations in south Florida.
[km2, square kilometers; ?, date uncertain; -, no data]
Begin End Feature year year 1881 1896 First canals to drain 400 km2 near lake Okeechobee.
1906 1909 Launching of publicly funded dredge ships, Everglades, Okeechobee, Caloosahatchee, and Miami.
1908 1932 Dynamiting of the Miami Rapids, dredging of the Miami Canal.
1910 - Small 2-m-high earth dike built along part of the southern shoreline of Lake Okeechobee.
1912 1917 Florida City (C-105), Snake Creek (C-9), and Snapper Creek (C-2) Canals.
1919 1928 Tamiami Canal dredged as far west as the L-28 canal.
? 1922 The Model Land (C-107 and C-107S), North (C-104), and Goulds (C-101) Canals.
1922 - Enlarged Lake Okeechobee dike.
1925 1928 Biscayne (C-8) and Little River (C-7) Canals.
1925 1934 Completion of the Comfort Canal.
1925 1927 many small canals in Miami-Dade County.
1930 1938 Herbert Hoover Dike installed at Lake Okeechobee.
1942 1945 Replacement of first water control structure on Miami Canal by a pneumatic dam. This failed in 1945 and was in turn replaced by a sheet pile structure.
? 1945 Initial Military, Mowry (C-103) canals and FEC Railroad and Card Sound Road borrow ditches.
1945 1946 Sheet pile salinity control structures installed on Coral Gables, Little River, Snapper Creek, Snake Creek, and Tamiami Canals.
1950 1960 Levee system on the western side of the urban development, L-30, L-31N, and L-33 Canals, extension of Little River Canal (C-7), Snake Creek (C-9), and Snapper Creek (C-2) Canals, and installation of salinity control structures S-22, S-27, and S-29.
1960s - Expansion of Herbert Hoover Dike.
1960 1968 Aerojet (C-111), Belle Air (C-1N), Black Creek (C-1), Cutler Drain (C-100), L-31E, L-67, and Princeton (C-102) Ca-nals and extension of Biscayne Canal (C-8), Little River (C-7), Mowry (C-103), L-31N Canals, installation of salinity control structures S-20, S-20F, S-21, S-21A, S-28, S-123.
1970 1978 C-109, and C-110 Canals, expansion of Card Sound Road Borrow Ditch to create The Card Sound Road Canal (C-108).
Installation of salinity control structures S-26, S-25B, S-25, S-25A, and S-336. C-109 and C-110 not fully completed.
In addition to the drainage caused by canals, withdrawals The control structure leaked considerably, and it had a gate from the aquifer for public, residential, and industrial water that had to be periodically lifted to allow the passage of supply increased as population increased (table 2). The first barges. It was eventually replaced by better structures. The public supply wells were installed in 1899. The well drilled Coconut Grove well field began to yield saltwater in 1933 and closest to the Miami River became saline within about a year. had to be abandoned in 1941. A USGS study by Cross and The Spring Gardens well field was installed in 1907 as a Love (1942) indicated that (1) saltwater had intruded 3.2 km replacement for the first public supply wells, but it started to inland into the Biscayne aquifer and several kilometers farther become saline in 1919 and was replaced by new well fields in inland along the Miami Canal, (2) saltwater was leaking from Miami Springs and Coconut Grove in 1924 and 1925, respec- the canals and encroaching along the base of the Biscayne tively (fig. 1, table 2) (Parker and others, 1955, p. 705; South aquifer, (3) groundwater levels near the Miami Canal were Florida Water Management District, 2010). By 1942 nearly below nearby canal stages and were drawing saltwater into 10,000 domestic, public, and industrial water supply wells the aquifer, and (4) two small lakes that were open to the had been installed in Miami-Dade County; these wells ranged Miami Canal had become saline, and this saltwater seeped into in depth from a few meters to 37 m or more (Cross and the aquifer where it flowed downgradient toward the Miami Love, 1942, p. 490). Springs well field.
In 1938-1939 a major drought (fig. 4) exacerbated the Parker and others (1955, p. 589-680) write that during effects of changes in the hydrologic system. Some of the wells the 1943-46 drought, saltwater migrated at least 6 km inland in the Miami Springs and Hialeah well fields nearest to the from the mouths of all of the canals, except possibly the Miami Canal, and numerous private water supply wells near Goulds and Mowry Canals, which were not sampled farther tidal canals, began to become saline (Parker and others, 1955, inland. In eight of these canals, saltwater migrated 11 to 20 km
- p. 587-691). To protect the well fields, a water control inland. Between 1944 and 1945, freshwater runoff ceased structure was installed in the Miami Canal in 1939 (fig. 12). in several of the shorter canals, and highly saline water was
Origin of Saltwater Intrusion in Southeastern Florida 19 Table 2. Partial history (1899-2001) of well field installations and operations in Miami-Dade County, Florida.
[-, no data]
Begin year End year Feature 1899 - First city of Miami public water supply wells.
1907 1919 Installation and modifications to the Spring Gardens well field.
1919 - Spring Gardens Well Field began to yield salty water.
1924 - Installation of the lower Miami Springs well field (8 wells) as a replacement for the Spring Gardens well field.
1925 1937 Installation (initially two wells) and subsequent modification of the Coconut Grove well field.
1933 - Coconut Grove well field first became salty.
1936 1954 Installation of Upper Miami Springs well field (4 wells), expanded in 1945, 1949, and 1954 (total of 12 wells).
1936 - Installation of Hialeah well field (three wells).
1941 - Coconut Grove well field had to be abandoned because of saltwater encroachment.
1942 - By this year, an estimated 10,000 domestic, public, and industrial water supply wells had been installed.
1949 1964 Installation of Alexander Orr well field (4 wells) expanded in 1952 and 1964 to total of 10 wells.
1953 1971 Installation of Leisure City well field.
1953 1997 Installation of Southwest well field.
1966 1972 Installation of Preston well field.
1975 - Installation of Medley and Naranja well fields.
1976 1982 Installation of Snapper Creek and Northwest well fields.
2000 2001 Installation of the Newton well field.
Figure 11. Rapids of the Miami River prior to their destruction by Figure 12. First water control structure on the Miami Canal dynamiting to increase drainage of the Everglades. From Smith, installed in December 1939. This structure leaked considerably 1909. Courtesy of History Miami Archives and Research Center. and also was opened to allow barges to pass. Photograph from the files of the U.S. Geological Survey.
20 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater observed entering the ground with visible velocity (Parker been relatively minor compared to the changes that occurred and others 1955, p. 630). Parker and others (1955, p. 589-590) between 1904 and 1946 (Parker and others, 1955, p. 589, indicated that during 1943 to 1946 the greatest advance of fig. 169; Renken and others, 2005a, figs. 53-55).
saltwater encroachment occurred in the Biscayne aquifer.
They found that in a 27-month period between 1943 and 1944 saltwater encroached landward by 610 m, which was a rate of 270 meters per year (m/yr). Data Collection and Analysis In 1945, having received the authority to control water levels in canals within its boundaries through a legislative Site location and construction information for sites act, Dade County (currently named Miami-Dade County) used to evaluate the inland extent of saltwater or the causes began to install numerous salinity control structures that of saltwater intrusion in the Biscayne aquifer is provided were effective in controlling salinity (Parker and others, in appendix 1. Monitoring results from a few of these sites 1955, p. 589). During the 1950s and 1960s, additional canals are provided in this report. Monitoring results from the and more technologically advanced control structures were remaining sites are available from the USGS Annual Water built with the dual purposes of preventing extensive flooding Data Reports and National Water Information SystemWeb by allowing sufficient drainage during tropical storms and interfaceWater quality samples for the Nation websites maintaining freshwater heads sufficient to prevent further (U.S. Geological Survey, 2011e, f) or from the organiza-saltwater intrusion. During the first 2 years of the 1970 to tions listed in appendix 1. The results of 69 geochemical 1977 drought (fig. 4), however, saltwater in the Miami Canal samples and 3 replicate samples from 44 sites are provided upstream of salinity control structure S-26 came to within in appendix 2. Salinity profiles were collected in the Card 1.6 km of the Miami Springs and Hialeah (currently named the Sound Road Canal to evaluate the extent to which saltwater Hialeah-Preston) well fields (Benson and Gardner, 1974) and can flow inland along this canal (appendix 3). Information increased the salinity of samples from wells near the Miami concerning the TEM soundings is provided in appendix 4.
Canal (fig. 13). Although saltwater continues to leak past The methods used to develop TSEMIL datasets are provided many of the water control structures in Miami-Dade County, in appendix 5. A comparison of the depth of the base of the since the late 1970s, the chloride concentration in samples Biscayne aquifer to the models of TEM soundings is provided from monitoring wells near the Miami-Canal have decreased in appendix 6. To improve the saltwater monitoring network, (fig. 13), and the changes in the inland extent of saltwater have eight new monitoring wells (fig. 8) were installed during 2,500 EXPLANATION 1943 1949 1960 1970 1980 1984 2000 1984 Drought period to to to to to to and date(s) 1946 1957 1963 1977 1982 1990 Monitoring 2,000 wells G-355 Chloride concentration, in milligrams per liter G-548 G-1351 G-1354 1,500 Saltwater Saltwater upstream 1,000 upstream of S-26 of S-26 1970-77 1939-40 1943-45 500 0 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 Year Figure 13. Chloride concentration in samples from monitoring wells G-355, G-548, G-1351, and G-1354 near the Miami Canal and between 0.6 and 2.4 kilometers northwest of salinity control structure S-26, Miami-Dade County, Florida.
Data Collection and Analysis 21 this study, and a suite of geophysical logs were collected The Kemmerer captures a sample from the bottom of the well prior to completion of the wells. Information concerning the where salinity is likely the greatest.
installation of these eight monitoring wells and other data Each organization involved in the collection of salinity collected in these wells are included in appendix 7, and the data determined the constituents or parameters to be measured geophysical logs collected from these wells are provided in and how those parameters were reported. In some instances, appendix 8. The hydrostratigraphic analyses using information the same organization may have reported results differently from these new wells are included in appendix 9. Sampling through time. Chloride concentrations generally were methods, sample analyses, and quality assurance are described expressed as either milligrams per liter or parts per million of in appendix 10. Monthly measurements of salinity in canals chloride. Salinity was reported as practical salinity units and collected by the Miami-Dade County Permitting, Environ- also as parts per thousand. The salinity units are approximately mental, and Regulatory Affairs (M-D PERA; Maria Idia equivalent but cannot be directly converted without additional Macfarlane, Water and Sewer Department, written commun., information. These parameters are therefore reported in the March 7, 2011; Craig Grossenbacher, Miami-Dade County same units used by the organizations that provided the data.
Permitting, Environmental, and Regulatory Affairs, written Metric equivalents are provided where necessary.
commun., July 7, 2010) are provided in appendix 11.
Time-Series Electromagnetic Induction Logging Salinity Measurements In Miami-Dade County, salinity monitoring wells have Salinity data from about 2,000 active or inactive sites been installed with polyvinyl chloride (PVC) casings and annular within the study area were available for evaluation of the inland seal materials that do not impede the induction of electromag-extent of saltwater. Most of these sites, however, were not netic energy in the aquifer. EMI logs, which consist of measure-close enough to the saltwater front, or at the necessary depth, ments of the bulk conductivity or resistivity of earth materials to aid in mapping the saltwater front. Numerous sites also throughout the depth penetrated by the wells, can be collected in were sampled by local and regional organizations. Only those these wells. The radius of investigation is 20 to 100 centimeters actively monitored sites that were used to map the saltwater (cm) from the center of the borehole (McNeill and others, 1990, front are included in appendix 1 and shown in figure 8. p. 1). The freshwater-saturated sand and limestone sediments In some areas, long open-interval wells were the of the Biscayne aquifer generally have relatively low bulk only wells available. Studies in Miami-Dade County and conductivities (10 to 30 millisiemens per meter [mS/m]), but elsewhere have determined that fresh and saltwater within where the sediments have been intruded by saltwater, bulk the open intervals of long open-interval wells may mix conductivity is higher. Therefore, EMI logs can be used to (Kohout and Hoy, 1963; Oki and Presley, 2008; Shalev and identify the depths at which saltwater occurs in the aquifer.
others, 2009). The Biscayne aquifer has been shown to have Moreover, because EMI measurements can be collected through cyclostratigraphic layers with three alternating forms of PVC casing, the possibility of ambient vertical borehole flow can porosity (Cunningham and others, 2006b), and some of the be eliminated. In south Florida, the USGS began to collect EMI layers have been shown to be laterally extensive. As a result, logs from short-screened PVC-cased monitoring wells in 1995.
natural head differentials can exist between these layers. Open Table 3. Vertical flows measured in open boreholes prior to well boreholes that pierce layers with head differentials can allow installation, 2009-2011, Miami-Dade County, Florida.
ambient vertical flow within the borehole. Geophysical logs collected in the boreholes of wells installed during this study [L/min, liters per minute; m, meter; -, no data]
near the edge of the saltwater interface in the Biscayne aquifer confirm the occurrence of extreme variations in porosity and Maximum Depth of Maximum Depth of vertical ambient flow within the borehole. Heat pulse flowmeter Local up-hole maximum down-hole maximum measurements collected in the boreholes of six of the eight identifier flow rate up-hole flow rate down-hole flow new wells (G-3885, G-3886, G-3887, G-3888, G-3947, and (L/min) flow (m) (L/min) (m)
G-3949) indicated maximum up-hole or and down-hole vertical G-3885 0.45 16.8 0 -
flow rates of 2.31 and -5.45 liters per minute (L/min) (table 3)
G-3886 2.31 16.5 -0.72 22.9 respectively. These flow rates indicate that certain types of samples and measurements from long open-interval wells in the G-3887 1.4 15.2 0 -
Biscayne aquifer may not be representative of the aquifer. G-3888 1.48 14.2 0 -
If long open-interval wells were the only wells available G-3946 0.15 12.6 0 -
in some areas, data collected from them were used to determine if the saltwater interface occurred in a well. A G-3947 0 - -5.45 31.7 to 36.0, non-isokinetic thief sampler called a Kemmerer (Lane and 38.1 to 39.3 others, 2003, p. 33-34) was used by the USGS to sample G-3948 0 - 0 -
long open-interval wells to minimize the mixing that could G-3949 0.42 25.9 0.04 -
be caused when the well is pumped (Kohout and Hoy, 1963).
22 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A time series of EMI logs can provide a detailed understanding limitation of induction logging equipment to provide a full of the movement of saltwater through the Biscayne aquifer that response to hydrostratigraphic layers thinner than 4 m (Taylor would not be possible using other methods. and others, 1989).
The current study used EMI logs that had been collected in 35 wells in Miami-Dade County. Some of these wells were logged only once, but sets of EMI logs that were collected Time-Domain Electromagnetic Soundings annually or semiannually are available for the majority of TEM soundings are surface geophysical measurements these wells. The EMI logs were used to (1) provide informa-that have been used extensively in south Florida since 1994 to tion about the thickness of saltwater occurring in the Biscayne evaluate the inland extent of saltwater in the Biscayne aquifer aquifer, (2) evaluate TEM sounding models, (3) calibrate (Sonenshein, 1997; Fitterman and others, 1999; Hittle, 1999; the HEM survey, and (4) provide insights into occurrence of Schmerge, 2001; Stewart and others, 2002) and to aid in the saltwater in the aquifer. As part of the current study, a meth-calibration and interpretation of results from a December odology was developed to process individual EMI logs into 1994 HEM survey in the Everglades (Fitterman and Deszcz-a TSEMIL dataset that was used to evaluate relatively small Pan, 1998). Seventy-nine TEM soundings were collected temporal changes in bulk conductivity (appendix 5).
during 2008 and 2009 to aid in mapping the inland extent of Many of the older wells, from which TSEMIL datasets saltwater in the Biscayne aquifer and to provide information were collected, do not penetrate beyond the base of the Biscayne to calibrate the HEM survey (fig. 8, appendix 4). Detailed aquifer; therefore, if saltwater did occur below the base of the information and the final models developed for each of these aquifer, it was not shown by these logs. The thickness of the TEM soundings are provided in Fitterman and Prinos (2011).
saltwater wedge determined with TSEMIL datasets is therefore Additional information concerning the TEM method in general based on the thickness of the saltwater lens within the Biscayne is provided by Kaufman and Keller (1983), Fitterman (1989),
aquifer itself. Although figures showing TSEMIL datasets are McNeill (1990), and Fitterman and Labson (2005).
not provided in this report for all sites where they were used, these datasets are readily available in the USGS online Annual Water Data Reports (U.S. Geological Survey, 2011e). HEM Survey Analysis The 2001 HEM survey processed during this study Comparison of Bulk Resistivity to Specific provided much more detailed information concerning the Conductance of Water and Chloride extent of saltwater than previously existed in the Model Land Concentration area (fig. 1). The Model Land area in southeast Miami-Dade County, south of the Florida City Canal and east of U.S.
EMI logs collected by the USGS in Miami-Dade County Highway 1, is the location of a wetland restoration project.
(U.S. Geological Survey, 2011e) indicate that freshwater- The survey area covered about 115 km2 of the southernmost saturated materials of the Biscayne aquifer typically vary in part of the study area (fig. 1). The survey consisted of densely bulk resistivity from approximately 35 to 220 ohm-meters spaced frequency-domain electromagnetic (FEM) measure-(ohm-m) and have an average bulk resistivity of approxi- ments collected using an instrument package suspended 30-m mately 80 ohm-m. Data from EMI logs and water samples below a helicopter. Measurements were collected by passing collected during the spring of 2009 from the Biscayne aquifer a sinusoidally varying current through multi-turn transmitter in Miami-Dade County were used to establish a relation coils. Five horizontal coplanar coil pairs operating at nominal between the bulk resistivity of the formation (including the frequencies of 400, 1,500, 6,400, 25,000, and 100,000 hertz water and the rock) and the electrical resistivity of the water (Hz) were used. The conversion of these measured fields to (fig. 14) (Fitterman and Prinos, 2011). A relation between the apparent and differential resistivity is described in Fitterman chloride concentration in water samples and the resistivity of and others (2012). Resistivity-depth functions were obtained these water samples (fig. 15) (Fitterman and Prinos, 2011) was from a differential resistivity-depth analysis. These functions combined with the relation between bulk resistivity and water were used to create resistivity-depth-slice maps ranging resistivity to determine that parts of the aquifer saturated with in depth from 5 to 100 m. East-west and north-south cross saltwater (1,000 mg/L of chloride or more) would have forma- sections of resistivity that coincided with the flight lines tion resistivities of about 10 ohm-m or less. Bulk resistivities also were created. All of the cross sections and depth slices ranging between 10 and 15 ohm-m were considered indicative processed during the current study are provided in Fitterman of the mixing zone at the leading edge of saltwater intrusion and others (2012); figure 16 shows an example of the and the mapped extent of saltwater intrusion was plotted to be 30-m-depth slice.
very close to these measurements. The maps and cross sections indicate a relatively The relation between the bulk resistivity of the formation sharp transition zone where differential resistivity generally and the electrical resistivity of the water is affected by decreased from 70 to 35 ohm-m across a horizontal distance variations in porosity and lithology and by potential measure- of about 300 to 600 m (Fitterman and others, 2012). Based ment errors. One type of measurement error is caused by the on information from sampled monitoring wells and TEM
Data Collection and Analysis 23 100 Formation resistivity, in ohm-meters 10 y = 5.0751x R² = 0.9285 1
0.1 1.0 10.0 100.0 Water resistivity, in ohm-meters Figure 14. Relation between the resistivity of water samples collected in monitoring wells in Miami-Dade County, Florida, and the formation resistivity measured by electromagnetic induction logs in the screened intervals of the same well.
Measurements symbolized by open circles were not used for the regression.
100 y = 310.2x-0.704 R2 = 0.9695 Water resistivity in ohm-meters 10 1
0.1 10 100 1,000 10,000 Chloride concentration, in milligrams per liter Figure 15. Relation between water resistivity and chloride concentration in water samples from monitoring wells in Miami-Dade County, Florida. From Fitterman and Prinos (2011).
24 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 8030'00" 8022'30" Sec34-MW-02-FS Sec34-MW-01-FS MIA201 MIA203 MIA202 G-1264 G-3164 MIA225 MIA206 Sec34-MW-03-FS MIA207 MIA205 MIA204 MIA208 CEMEX-MW-03-FS MIA215 MIA209 MIA229 G-3166 MIA210 MIA226 MIA214 MIA230 MIA227 G-3946 MIA211 MIA228 MIA213F MIA236 MIA234 MIA212F FKS 8 MIA231 MIA233F 27.4 E
L-31 MIA232 MIA216 MIA235F MIA217 MIA223 MIA224 2522'30" FKS 7 G-3342 FKS 4
- 24. 4 FKS 5 MIA222 MIA220 MIA219F MIA221 CA RD SO UN FKS 3 DR OA D
FKS 2 G-1256 MIA218F 15.2 C-1 11 3
21.
EXPLANATION U.S. HW 18.3 Canal Inverted resistivity, Minor canals in ohm-meters Y. 1 Creek Powerline, large 100.0 Powerline, small 70.0 Base from U.S. Geological Survey digital data, Universal 0 1 2 KILOMETERS Transverse Mercator projection, zone 17N, NAD 83 Road 55.0 0 1 2 MILES Extent of saltwater intrusion 45.0 (ESI) in 2011 (Prinos, 2011). Dashed 35.0 where data are insufficient to 29.0 accurately locate Extent of saltwater intrusion in 18.0 1995 (Sonenshein, 1997). Dashed 12.0 where data are insufficient to 7.2 accurately locate 2.8 Depth below sea level to base of Biscayne aquifer, 1.7 in meters (Fish and Stewart, 1991) 1.1 MIA224 Time domain electromagnetic 0.5 sounding FKS 4 Well location and number Figure 16. Example of a depth slice from the 2001 helicopter electromagnetic survey, Miami-Dade County, Florida. Modified from Fitterman and others (2012).
Approximate Inland Extent of Saltwater in the Biscayne Aquifer 25 soundings collected in this area, this transition zone was the saltwater front has either advanced or retreated. These interpreted to be the saltwater interface. To determine the estimations are based on changes apparent in the monitoring inland extent of saltwater in the HEM survey area, the data, but are relatively coarse approximations because the 45-ohm-m differential resistivity contour of each of the depth relation between the amount of front movement and amount of slices was mapped. This map provided a three-dimensional change in salinity is variable.
representation of the saltwater interface. The intersection of The precision of the estimated inland extent of the this interface with the base of the Biscayne aquifer interpo- saltwater front depends on the availability of monitoring data lated from the map of Fish and Stewart (1991) was mapped and/or the geophysical spatial coverage. For example the and represents the inland extent of saltwater in the Biscayne Model Land area south of the Florida City Canal and east of aquifer in 2001. This information was used to create the 2008 U.S. Highway 1 had long been an area where little information preliminary map of the inland extent of saltwater intrusion in was available for mapping the inland extent of saltwater. As this area. Thirty-six additional TEM soundings collected in the a result, the inland extents of saltwater estimated by the maps spring of 2009 and 4 new wells were used to verify or update produced in 1955 and 1995 (fig. 8) differed in this area by 1 to the inland extent of saltwater in 2011 (fig. 8). 4 km. Spatial coverage in the Model Land area was greatly improved during the current study through the collection of numerous TEM soundings (Fitterman and Prinos, 2011),
the processing of the 2001 HEM survey (Fitterman and Approximate Inland Extent of others, 2012), and the installation of new monitoring wells.
Saltwater in the Biscayne Aquifer In this area, relatively dense surface geophysical coverage was possible because of the many large open fields that were The approximate inland extent of saltwater in the relatively free of anthropogenic interference.
Biscayne aquifer (appendix 12) was determined by using Surface geophysical measurements also improved spatial (1) salinity measurements of groundwater and surface water coverage elsewhere in Miami-Dade County, particularly where (chloride, total dissolved solids [TDS], or specific conduc- one measurement occurred on one side of the interface and tance), (2) borehole EMI data, (3) TEM data, and (4) HEM another occurred on the opposite side. Unfortunately, surface survey data collected in 2001. The word approximate is geophysical measurements could not be collected everywhere used because the 1995 and 2011 maps are considered to because some areas were too heavily developed to allow the be approximations of the inland extent of saltwater. Where collection of surface geophysical data given the transmit coil chloride concentration information exists from wells that size required. In these areas, the distance between monitoring fully penetrate the aquifer, the mapped line represents the wells ranges from 0.5 to 5 km. The approximate extent of approximate position of the 1,000-mg/L isochlor at the base saltwater intrusion is less reliable in areas where monitoring of the Biscayne aquifer. Where constrained by EMI logs or wells are widely spaced and surface geophysical measure-ments could not be made.
TEM soundings, this line represents the landward limit of the Most of the time-series data used to evaluate movement occurrence of aquifer materials (including water) measured of the saltwater front were collected by the USGS and are or modeled to have a bulk resistivity of less than 10 ohm-m.
readily available online (U.S. Geological Survey, 2011e, Resistivities between 10-15 ohm-m are considered indicative 2011f, 2011g). It is not feasible to include all of these data in of the mixing zone at the leading edge of the saltwater front.
this report, but examples of the changes in chloride concentra-Resistivities greater than 15 ohm-m indicate freshwater tion that have occurred are shown in figure 18. Examples saturated materials.
of the TSEMIL datasets are provided in the Time-Series Elec-tromagnetic Induction Logging section of this report. Results Improved Spatial Coverage and Precision of the of all TEM soundings used to map the location of the saltwater Inland Extent of Saltwater front are published in the companion report (Fitterman and Prinos, 2011; appendix 4).
Mapped changes of the inland extent of saltwater between 1995 and 2011 (fig. 17) are the result of improved Changes between 1995 and 2011 spatial information, actual movement of the saltwater front, or a combination of both. The water-quality measurements and The saltwater front was mapped farther inland in 2011 samples and geophysical information collected or processed than in 1995 (figs. 8 and 17) in eight approximated areas during this study provided better spatial coverage than had totaling 24.1 km2. These eight areas are (1) a 4.5-km2 area in existed in 1995 when the extent of saltwater was last mapped. northern Miami-Dade and southern Broward Counties from This was particularly true in the Model Land area where there just south of the Biscayne Canal to the city of Hallandale was insufficient information available to accurately determine Beach, (2) a 3.2-km2 area near Interstate 95, extending from the inland extent of saltwater in 1995 (Sonenshein, 1997). north of the Little River Canal to Interstate 195, (3) a 2.0-km2 Estimated advances or retreats of the saltwater front are area from the Miami Canal to a little south of the Comfort provided in areas where existing information indicates that Canal, (4) a 1.2-km2 area between SW 8 Street (Tamiami
26 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 80°30' 80°20' 80°10' 95 820 "
L-33 7 HOLLYWOOD 26°00' 67A L- L-67 HALLANDALE C
75 BEACH "
BROWARD Snake Creek Ca COUNTY n al MIAMI-DADE 997 (C
-9 COUNTY
)
821 826 Biscayne Canal (C
-8)
L-30 Little River Canal 9 M "
iam i HIALEAH 25°50' an C MIAMI al SPRINGS "
(C 195
-6 NW 36 STREET )
836 Comfort Canal "
Tamiami Canal (C-4) MIAMI SW 8 STREET OCEAN COCONUT (TAMIAMI TRAIL)
GROVE "
ATLANTIC SW 72 STREET (SUNSET DRIVE)
Snapper SW 104 STREET Creek (KILLIAN PARKWAY) 25°40' Canal PINECREST (C-2)
Florida Turnpike SW 72 AVENUE L-31N SW 136 STREET (HOWARD DRIVE)
SW 184 STREET (EUREKA DRIVE) 1
" CUTLER BAY Pri SW 200 STREET (CUTLER RIDGE DRIVE) nce Goulds Canal ton Canal (C-102)
SW 288 STREET (BISCAYNE DRIVE)
M Bay ow 25°30' ry ne Cana cay l (C-103) EXPLANATION HOMESTEAD "
Bis North Canal Origin and delineation of saltwater intrusion and Florida City Canal basis for modifications to mapped extent SW 344 STREET (PALM DRIVE)
FLORIDA Historical leakage of saltwater from canal. Chloride CITY content estimated to be less than 1,000 milligram SW 137 AVENUE per liter and gradually dissipating 1
MODEL TENNESSEE ROAD LAND FPL Cooling Advance of the saltwater front since 1995 Form Modal Land Canal Canal System Retreat of the saltwater front since 1995 SO Ae (C-107) ro l
je a
RD t
C-110 an Recent leakage of saltwater from canal CA C
Canal (C-111) o ad Ditch Landward revision of saltwater front based on dR D
UN orrow 25°20' un new information So way B AD C Rail rd RO nd ou Seaward revision of saltwater front based on Ca of FE S
ation ard new information er loc C
Previously intruded as of 1995 C-109 (plugged)
Approximate inland extent of saltwater in 2011.
Bar Dashed where information was insufficient n
Sou es for an accurate estimate nd Base from Miami-Dade County, South Florida Water Management 0 5 10 KILOMETERS and U.S. Geological Survey digital data, Universal Transverse Mercator projection, zone 17N, NAD 83 0 5 10 MILES Figure 17. Origin and delineation of saltwater intrusion in the Biscayne aquifer and the basis for modifications to its mapped extent. Enlarged version of this figure available for download at http://pubs.usgs.gov/sir/2014/5025/downloads/sir2014-5025_figure17large.pdf.
Approximate Inland Extent of Saltwater in the Biscayne Aquifer 27 6,000 700 5,000 G-1179 600 G-896 500 4,000 400 3,000 300 2,000 200 1,000 100 0 0 12,000 120 10,000 G-3699 100 G-3603 Chloride concentration, in milligrams per liter Chloride concentration, in milligrams per liter 8,000 80 6,000 60 4,000 40 2,000 20 0 0 6,000 2,500 5,000 G-1264 2,000 G-3605 4,000 1,500 3,000 1,000 2,000 1,000 500 0 0 2,500 2,500 2,000 G-3229 2,000 G-3698 1,500 1,500 1,000 1,000 500 500 0 0 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 Year Year 4,000 3,500 G-894 Chloride concentration, in milligrams per liter 3,000 2,500 2,000 1,500 1,000 500 0
1,600 1,400 G-3162 1,200 1,000 800 600 400 200 0 1950 1952 1954 1956 1958 1960 1962 1964 1966 1968 1970 1972 1974 1976 1978 1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 Year Figure 18. Chloride concentrations in water samples from long-term monitoring wells (see fig. 8 for well locations).
28 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Trail) and the Coral Gables Canal, (5) a 0.5-km2 area in the the TEM soundings collected in 2008 and 2009 (Fitterman and city of Pinecrest between SW 104 Street (Killian Parkway) Prinos, 2011), the HEM survey collected in the Model Land and SW 136 Street (Howard Drive), (6) a 0.3-km2 area in the (Fitterman and others, 2012), a HEM survey in the Everglades city of Cutler Bay, between SW 184 Street (Eureka Drive) and National Park and surrounding areas (Fitterman and Deszcz-SW 200 Street (Cutler Ridge Drive), (7) a 7.1-km2 area in or Pan, 1998, 2002), and new monitoring wells installed during near the cities of Florida City and Homestead, extending from this study by EAS Engineering, Inc., Florida Power and Light a little south of the Military Canal to a little south of FKAA (FPL), Miami-Dade County, and the USGS. Decreases in the well G-1264 (fig. 8), and (8) a 5.3-km2 area south of Florida chloride concentrations in wells G-896 and G-1179 (fig. 18)
City in the vicinity of U.S. Highway 1 and Card Sound Road. indicate that some of the change in the mapped position of the In most of these areas, the difference between mapped extent front near these wells resulted from movement of the front, of saltwater in 1995 and 2011 is likely caused by improved rather than from improved spatial coverage alone.
spatial coverage or a combination of advances of the saltwater front and improved spatial coverage. Landward movement of the front is inferred from increases in the chloride concentra-tion in water samples or increases in the bulk conductivity Characterization and Distribution of of EMI logs from monitoring wells used for this evaluation Saltwater in the Biscayne Aquifer (fig. 8, appendixes 1 and 5). Examples of the increases in the chloride concentrations in samples are shown in figure 18. Water managers need to understand the origin of intruded In two areas, the differences between the 1995 and saltwater and the temporal and spatial changes in its distribu-2011 maps are likely caused solely by front movement. In tion to evaluate the potential for saltwater intrusion at coastal the area between SW 8 Street and the Coral Gables Canal, well fields. Saltwater that intruded early in the 20th century analysis of water samples from well G-3229 (figs. 8 and 18) and is gradually dissipating may pose less of a concern, for indicated an increase in chloride concentration from about example, than saltwater that is actively leaking from a canal 600 mg/L to 1,640 mg/L between December 1996 and near a well field. If the sources of saltwater are misidentified, September 2011 (fig. 18). The saltwater front, which had been the corrective measures implemented to prevent saltwater approximately 60 m southeast of well G-3229 in 1995, had intrusion could fail to address the actual issue. Differentiating moved 230 m farther inland by 2011. Near Florida City and between saltwater that previously intruded the aquifer and Homestead near SW 344 Street (Palm Drive), the saltwater saltwater that is actively intruding can be difficult because front had been mapped about 0.5 km east of well G-3699 saltwater of various origins and ages may mix.
(fig. 8) in 1995. This well was installed in 1999, and the first Water samples were analyzed to determine (1) major chloride concentration sampled was 950 mg/L. The chloride and trace ion geochemistry, (2) strontium isotopic ratios, concentration in samples had increased to 9,700 mg/L by (3) oxygen and hydrogen stable isotopic ratios, (4) tritium 2011, and monitoring wells G-3855 and G-3856 located west concentrations, (5) 3H/3He concentrations, (6) sulfur hexafluo-of well G-3699 have become saline. Based on this informa- ride concentrations, and (7) dissolved gas concentrations. The tion, the saltwater front was mapped to be about 1.4 km west concentrations of 3H/3He and sulfur hexafluoride were used to of well G-3699 and is interpreted as having advanced by interpret the ages of water samples. These analyses, coupled about 1.9 km between 1995 and 2011 near SW 344 Street. with other types of information, were used to evaluate the Water samples from wells G-1264 and G-3698 located prevailing climatic conditions during which saltwater intruded south and north of well G-3699, respectively, also indicated the Biscayne aquifer, timeframes for this intrusion, and the increases in chloride concentration during this same period chemical interactions between the intruded saltwater and (fig. 18), and the front appears to have advanced landward the aquifer.
in this area. The changes occurring in the vicinity of wells G-1264, G-3698, and G-3699 are described in greater detail in subsequent sections of this report. Major and Trace Ion Geochemistry The saltwater front was mapped closer to the coast in 2011 than it was in 1995 (figs. 8, 17) in four approximated Ions, such as chloride and bromide, are conservative areas totaling about 6.2 km2. These areas are (1) a 0.7-km2 area indicators of freshwater and seawater mixing because between the cities of Coconut Grove and Pinecrest extending these ions generally do not adsorb or interact with aquifer from SW 72 Street (Sunset Drive) to SW 104 Street (Killian materials. The concentrations of many other ions, however, Parkway), (2) a 2.7-km2 area south of the city of Cutler Bay are affected by dissolution of aquifer materials, precipitation extending from SW 200 Street (Cutler Ridge Drive) to a little or reduction of chemical species, and adsorption onto or south of SW 288 Street (Biscayne Drive), (3) a 0.1-km2 area release from clay minerals, organic matter, oxyhydroxides, in the Model Land between SW 137 Avenue and Tennessee or fine-grained rock materials as mixing occurs, (Jones and Road, and (4) a 2.7-km2 area south of Florida City, between others, 1999, p. 61). These complex chemical changes occur U.S. Highway 1 and the C-111 Canal. The changes were iden- in a portion of the saltwater front called the ion-exchange tified based on improvements in spatial coverage provided by front (fig. 9), and may include exchange of sodium in
Characterization and Distribution of Saltwater in the Biscayne Aquifer 29 seawater with adsorbed calcium; adsorption of potassium, The concentrations of chloride and bromide generally boron, and lithium in seawater onto clay minerals (Jones and plot near the theoretical freshwater/seawater mixing line others, 1999, p. 66); enrichment in calcium and bicarbonate because these ions are conservative indicators of freshwater caused by dissolution of calcite and aragonite in carbonate and seawater mixing, and generally are not adsorbed by, or aquifers (Richter and Kreitler, 1993, p. 107; Jones and others, interact with, aquifer materials. As expected, the chloride and 1999, p. 61); reduction of the sulfate in seawater to hydrogen bromide concentrations in samples collected during the study sulfide under low redox conditions in the aquifer (Richter all plot close to the theoretical freshwater/seawater mixing and Kreitler, 1993, p. 107; Jones and others, 1999, p. 67); line (fig. 20). Concentrations of boron, magnesium, potassium, and exchange of calcium adsorbed on clay minerals with sodium, and sulfate were frequently depleted (figs. 21-25),
magnesium in seawater (Howard and Lloyd, 1983, p. 435; whereas the concentrations of calcium were frequently Richter and Kreitler, 1993). Causes for enrichment of barium enriched (fig. 26), relative to the theoretical freshwater/
seawater mixing line. The extent of depletion and enrichment in the freshwater/seawater mixing zone include desorption of varied and may indicate either the arrival of the saltwater surface-bound barium from aquifer particulates by replace-interface (sites highlighted in yellow) or the occurrence of ment with major seawater cations, and diagenetic reactions prior intrusion (sites highlighted in blue). Unlike the evalua-such as dissolution of authigenic barite, decomposition of tion of the Ca/(HCO3 + SO4) ratios, which was based on ratios barium-rich organic material, and dissolution of barium greater than or less than 1, comparisons of ion concentra-containing metal oxide phases (Shaw and others, 1998). tions to the theoretical freshwater/seawater mixing line are Richter and Kreitler (1993) state: These changes are most somewhat more subjective.
pronounced within the initial sea-water front that mixes Many of the wells from which samples had with fresh water. Subsequent intrusion deviates little from Ca/(HCO3 + SO4) ratios greater than 1 also were among the sea-water composition. wells most depleted in boron, magnesium, potassium, sodium, The ionic exchanges that occur as seawater mixes with and sulfate and most enriched in calcium relative to the theo-freshwater are indicated by deviations from the theoretical retical freshwater/seawater mixing lines. This group of wells freshwater/seawater mixing line that would be created solely includes G-3615, G-3698, G-3699, G-3704, and G-3855.
by mechanical mixing of freshwater and seawater (Howard Barium was enriched relative to the theoretical freshwater/
and Lloyd, 1983); the seawater end member for the mixing seawater mixing line (fig. 27) in four wells (G-3699, G-3615, line was taken from Turekian (1976), whereas the freshwater G-3704, and G-3855) that were more depleted in boron, end member was generally the average composition of water sodium, sulfate, magnesium, and potassium and more enriched samples collected from canals during this study. Seaward in calcium than most of the other wells. Similar patterns of of the ion-exchange front or at depths that are well below major ion concentrations were found in well G-1264 (with the freshwater/saltwater interface, there may be little or no the exception of boron, which was not measured), and well ion exchange because exchange sites of aquifer materials G-3705 (with the exception of sulfate). The described enrich-may be saturated and chemical equilibrium of seawater with ments and depletions relative to the theoretical freshwater/
aquifer materials may have been established. Where ion seawater mixing lines indicate ion exchanges that are typical exchange is not occurring, the concentration of ions in water of the arrival of saltwater intrusion. Concentrations of major samples should plot on the theoretical freshwater/seawater ions in wells FKS4, FKS8, G-939, G-3600, G-3601, G-3602, mixing line. G-3604, and G-3605 were less depleted and generally plotted A calcium to (bicarbonate + sulfate) molar ratio closer to the theoretical freshwater/seawater mixing lines than the concentrations of major ions in other wells, indicating that
[Ca/(HCO3 + SO4)] greater than 1 has been used to identify these wells are in areas where the aquifer materials are closer the arrival of saltwater intrusion at a given location in to equilibrium with seawater. Generally this is because the the aquifer where ion exchange results from the mixing of saltwater front has moved well inland of the locations of these freshwater and saltwater (Jones and others, 1999). Using this wells, but in some areas the situation is more complex (see, for criterion, the arrival of saltwater intrusion is indicated at example, the Miami and Tamiami Canals section of this report).
11 sites (wells G-901, G-1264, G-3615, G-3698, G-3699, Chloride to bromide (Cl/Br) mass ratios can be used to G-3704, G-3705, G-3855, G-3946D and one of each differentiate between rainfall (ratios of 50 to 150), shallow of the samples collected from wells F-279 and G-3701) groundwater (ratios of 100 to 200), and sewage effluent (ratios (table 2-1; fig. 19). A Ca/(HCO3 + SO4) molar ratio less than of 300 to 800) (Davis and others, 1998). Seawater has a Cl/Br 1 and a chloride concentration of 1,000 mg/L or more (fig. 19) mass ratio of about 288 to 297 (Turekian, 1976; Richter and indicated previous saltwater intrusion at 10 sites (wells FKS4, Kreitler, 1993, p. 28; Vengosh and Pankratov, 1998; Jones FKS8, G-939, G-3600, G-3601, G-3602, G-3604, G-3605, and others, 1999, p. 70). The Cl/Br mass ratio of most of the G-3609, and G-3702). Some sample results may be interme- groundwater-well samples ranged from 178 to 305, which diate between these conditions because the saltwater front may is close to the typical range for freshwater saturated and have passed the location, but some ion exchange sites may saltwater intruded groundwater. The Cl/Br mass ratio of most have remained available. of the canal water samples ranged from 235 to 304; likely a
30 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 3.0 2.8 EXPLANATION G-1264 Theoretical freshwater/seawater 2.6 mixing line Arrival of saltwater intrusion 2.4 Previously intruded 2.2 G-3855 Groundwater Calcium: (bicarbonate + sulfate) ratio Surface-water 2.0 G-3615 Seawater 1.8 G-3698 1.6 1.4 G-3705 G-3699 G-901 G-3704 1.2 G-3701 F-279 G-3946D 1.0 F-279 G-3609, G-3702 0.8 G-3856 G-3602 G-3605 0.6 G-939 FKS 4, G-3604 G-3601 G-3600 0.4 FKS 8 0.2 FKS 7, G-894, G-896, G-3603, G-3606, G-3607, G-3608, G-3610, G-3611, G-3700, G-3885 0
0 4,000 8,000 12,000 16,000 20,000 Chloride, in milligrams per liter Figure 19. Calcium to (bicarbonate + sulfate) ratio and the chloride concentration in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida. The composition of seawater used for this figure was described by Turekian (1976).
80 EXPLANATION Theoretical freshwater/seawater 70 mixing line Groundwater samples Groundwater replicate samples 60 Surface-water samples Seawater Bromide, in milligrams per liter 50 G-3600 F-279, G-939, G-3615 40 G-3699 30 G-3704 20 G-3604 G-3602 10 G-33855 G-3605 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 20. Bromide and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
Characterization and Distribution of Saltwater in the Biscayne Aquifer 31 1,400 EXPLANATION Theoretical freshwater/seawater 1,200 mixing line G-36 Arrival of saltwater intrusion 00 Previously intruded Groundwater sample 1,000 Magnesium, in milligrams per liter Groundwater replicate samples Surface-water sample Seawater 800 600 FK S
FK 8 S G-36 8
99 400 G FK G-FK -360 S 4 36 99 S 4 4
F-279, G-3946D G-93 G- 9 93 G- G- 9 G-200 36 90 G-37 05 1 36 02 04 G-3801, G-3609 G-G-3856 G-38 12 G-3615 55 64 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 G-3698, G-3705 Chloride, in milligrams per liter Figure 21. Magnesium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
450 EXPLANATION 400 Theoretical freshwater/seawater mixing line Arrival of saltwater intrusion 350 Previously intruded G-Groundwater sample 36 00 Groundwater replicate samples Potassium, in milligrams per liter 300 Surface-water sample Seawater 250 200 150 FK S
4 FK S
8 100 G- G-3604 G- 93 3 36 9 G-05 69 G-3602 9 50 G-3704 G-3601 G-90 G-3856 1 F-279, G-3946 G-1264 G-3615 G-3855 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 G-3609, G-3698 G-3705 Chloride, in milligrams per liter Figure 22. Potassium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
32 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 12,000 10,000 8,000 00 Sodium, in milligrams per liter G-36 6,000 FK EXPLANATION S
8 Theoretical freshwater/seawater G-4,000 36 mixing line 99 FK Arrival of saltwater intrusion S
G-3602 4 Previously intruded G-37 F-279 04 Groundwater sample G-G-939, G-3615 36 2,000 04 G-3855, G-3946D G- Groundwater replicate samples 12 64 Surface-water sample G-3605 G-G-3601 90 Seawater 1 G-939 G-3698, G-3705 G-3615 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 23. Sodium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
5,000 EXPLANATION 4,500 Theoretical freshwater/seawater mixing line Arrival of saltwater intrusion 4,000 Previously intruded Groundwater sample 3,500 Groundwater replicate samples Boron, in micrograms per liter Surface-water sample 3,000 Seawater G-36 00 2,500 2,000 1,500 G-36 1,000 04 36 G-99 G-939 F- G-3602 500 G-3601 27 G-9 37 G-3856 G-3702 04 G-3855 0 G-3698 G-3615 0 G-3701 2,000 G-3609 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 G-3705 Chloride, in milligrams per liter Figure 24. Boron and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
Characterization and Distribution of Saltwater in the Biscayne Aquifer 33 3,000 EXPLANATION Theoretical freshwater/seawater mixing line 2,500 Arrival of saltwater intrusion Previously intruded Groundwater sample Groundwater replicate samples 2,000 Sulfate, in milligrams per liter G-3600 Surface-water sample Seawater 1,500 FKS 8 1,000 F-279, G-939, G-3946D FKS 4 G-3699 G-3604 500 G-3704 G-3601, G-3705 G-3602 G-3605 G-901 G-3856 G-3609 G-3855, G-3615 G-3615 G-3698 G-1264 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 25. Sulfate and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
800 700 G-3699 600 Calcium, in milligrams per liter G-1264 500 G-3855 G-3600 G-3615 G-3704 400 F-279 G-3946D FKS 8 300 G-3705 G-3602 EXPLANATION G-901 FKS 4 Theoretical freshwater/seawater G-3698 mixing line 200 G-3609 G-3604 G-939 Arrival of saltwater intrusion G-3605 Previously intruded G-3601 G-3856 Groundwater sample 100 Groundwater replicate samples Surface-water sample Seawater 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 26. Calcium and chloride concentrations in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
34 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 400 EXPLANATION G-3704 Theoretical freshwater/seawater 350 mixing line Groundwater sample Groundwater replicate samples 300 Surface-water sample G-3699 Seawater Barium, in micrograms per liter 250 F-279 200 G-3855 G-3602 150 G-3701 G-3615 G-3609 G-939 G-3600 100 G-3604 G-3605 G-3601 G-3705 G-3698 50 G-3702 G-3856 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 27. Barium and chloride concentrations in samples.
result of the mixing of rainfall runoff with inflow from shallow analysis, but given their depths and locations, these wells also groundwater, as well as mixing of seawater in some instances. may be screened in the Tamiami Formation. The elevated The Cl/Br mass ratios in samples from wells F-45, G3600, silica concentration in samples from these four wells may have G-3603, G-3604, G-3607, G-3608, G-3610, G-3611 and resulted from relatively long residence times of water in the sites Canal C100A at SW 72 Ave, Canal at G-3698, C2 Canal quartz-sand-rich sediments of the Tamiami Formation.
at G-3608, C2 Canal 150 Ft Upstream of S-22, and C5 Canal at NW 32 Ct ranged from 306 to 682, which is within the range of sewage effluent (appendix 2, table 2-1). Strontium Isotope Age Dating A triangular-shaped theoretical freshwater/seawater Strontium isotopes were used to evaluate the origin of mixing area, within which most of the groundwater sample saltwater in the surficial and intermediate aquifer systems in results occur, is defined by the maximum and minimum silica southwest Florida (Schmerge, 2001). Strontium isotope age and chloride concentrations in surface water, and the concentra-dating uses the relation of age and the marine strontium-87 to tion of these same ions in seawater (fig. 28). Silica concentra- strontium-86 (87Sr/86Sr) ratio (Howarth and McArthur, 1997; tions in surface-water samples ranged from a low of 3.32 mg/L McArthur and others, 2012). Unlike 3H/3He and SF6 age dating, in the Card Sound Road Canal 7.7 mi Upstream from Mouth which provide estimates of the age of the water, 87Sr/86Sr to a high of 8.81 mg/L at C9 Canal near NE 17 Ave. Silica ages reflect the ages of the rock with which this water has was most enriched in groundwater samples from well G-3701 equilibrated. Most of the carbonate rocks in south Florida are (fig. 28), which is most likely open to the Pinecrest Sand marine in origin and the 87Sr/86Sr ratios in the minerals of the Member of the Tamiami Formation rather than to the Biscayne rock correspond to those of seawater during deposition. The aquifer. The Pinecrest Sand Member typically is characterized 87 Sr/86Sr ratios of groundwater samples, in turn, reflect those of as a fine quartz sand that has low (0.1 to 10 feet per day [ft/d]) the strata with which this water has equilibrated. This under-hydraulic conductivity (Reese and Cunningham, 2000). The standing can aid in determining whether the sampled water quartz in these sediments may have enriched the sampled emanates from the same strata from which it was sampled, or water in silica relative to the water that flowed through the from deeper or shallower strata. Although water with different carbonate Biscayne aquifer. Wells G-3600, G-3601, G-3602, 87 Sr/86Sr ages are mixed within an aquifer, water samples that and G-3603, which also were enriched in silica, are the four indicate older or younger 87Sr/86Sr ages than the ages of the deepest wells sampled. The lithologic descriptions from aquifer materials may indicate upward or downward leakage of these four wells are not sufficiently detailed for stratigraphic water from other aquifers (Schmerge, 2001).
Characterization and Distribution of Saltwater in the Biscayne Aquifer 35 20 EXPLANATION 18 Theoretical freshwater/seawater G-3701 mixing line Card Sound Road Canal 7.7 mi upstream 16 from mouth/ seawater mixing line C9 Canal near NE 17 Ave/seawater mixing line 14 Groundwater sample Silica, in milligrams per liter Surface-water sample 12 G-3602 Seawater G-3603 10 G-3601 C9 Canal near NE 17 Ave G-3609, G-3698, G-3702, G-3705 G-3604 8
G-3600 G-901 F-279 G-3605 G-939 6
G-3704 G-3615 G-1264 4 G-3855, G-3946D G-3856 G-3699 FKS4 FKS8 2 Card Sound Road Canal 7.7 mi upstream from mouth 0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 Chloride, in milligrams per liter Figure 28. Silica and chloride concentrations in samples.
The 87Sr/86Sr ratios of the 14 samples collected from The 87Sr/86Sr ages of water samples from wells groundwater wells during the current study range from G-3601 and G-3701 (1.87 and 1.66 Ma, respectively) do not 0.70909 to 0.70917 (+/- 0.00002) (table 4), which correspond coincide with the age of the Tamiami Formation; however, to interpolated mean 87Sr/86Sr ages of 1.87 to 0.19 million they are older than the ages of any other groundwater samples years (Ma) before present, respectively (table 4, McArthur and (table 4). These wells likely only penetrate a few meters others, 2012). Given the precision of 87Sr/86Sr ratio analyses, into the Pinecrest Sand Member. There may be mixing of the potential range in mean age is 2.51 to 0 Ma. This age range water between the geologic formation, therefore, which corresponds to the Pleistocene and Holocene Epochs (Walker could explain the 87Sr/86Sr ages of the water samples from and others, 2012) during which the strata of the Biscayne G-3601 and G-3701.
aquifer, including the Fort Thompson Formation, Key Largo Formation, Lake Flirt Marl, Miami Limestone, and Pamlico Sand, were deposited (fig. 6). The 87Sr/86Sr ages, therefore do Oxygen and Hydrogen Stable Isotopes not indicate any flow of deeper, older water into the Biscayne aquifer at these well locations. The concentrations of stable isotopes of hydrogen Although the 87Sr/86Sr ages of all samples correspond and oxygen in water are affected by fractionation during to the Holocene and Plestocene Epochs, wells G-3601 and evaporation and precipitation. Evaluations of the likely G-3701 are likely open to the upper most part of the Pinecrest sources from which water has originated can be aided by Sand Member of the Tamiami Formation deposited during the determination of the amount of fractionation that has occurred Pliocene Epoch. The Pinecrest Sand Member is considered to in water samples. The oxygen and hydrogen stable isotope be part of the Biscayne aquifer at the location of well G-3601. composition of precipitation follows a well-defined linear Well G-3601 is 57.9 m deep and the depth of the top of the trend known as the global meteoric water line (GMWL)
Pinecrest Sand Member is estimated to be about 55 m in this (Craig, 1961). Local evaporation causes systematic enrich-area (Fish and Stewart, 1991). The Pinecrest Sand Member ment of the heavier oxygen and hydrogen stable isotopes that underlies the Biscayne aquifer at the location of well G-3701. results in divergence of the stable isotopic composition of Well G-3701 is 25.3 m deep, and the depth of the base of the local surface water from the GMWL. The line showing this Biscayne aquifer at this location is estimated to be 20.5 m (see divergence is called the local evaporation line (LEL). The the Relict Seawater from Previous Sea-Level High Stands isotopic ratios of hydrogen (2H/1H) and oxygen (18O/16O) are section of this report). typically expressed as delta deuterium (2H) and delta oxygen
36 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 4. Determination of the strontium-87 to strontium-86 ratio in water samples collected during 2009, in Miami-Dade County, Florida.
[g/L, micrograms per liter; -, no data]
Interpolated mean Strontium-87 Strontium-87 Strontium strontium-87 to USGS station Local identifier Date to strontium-86 to strontium-86 concentration, strontium-86 age number ratio ratio rerun* in g/L in millions of years C1 CANAL AT G -3702 253334080213600 8/6/2009 0.70910 0.70910 824 1.66 C2 CANAL 150 FT 254012080170200 8/3/2009 0.70911 - 603 1.47 UPSTREAM OF S-22 C2 CANAL AT G-3608 254108080170600 7/28/2009 0.70909 - 607 1.87 C8 CANAL AT G-3601 255358080114100 8/17/2009 0.70914 - 588 0.95 F-279 255315080111501 8/2/2009 0.70914 - 3,110 0.95 FLORIDA CITY 252652080244300 8/20/2009 0.70919 - 807 0.00 CANAL AT G-3699 G-894 255350080105801 8/14/2009 0.70914 - 599 0.95 G-896 254107080165201 8/4/2009 0.70912 - 801 1.29 G-939 253652080183701 8/27/2009 0.70911 - 2,940 1.47 G-3601 255358080114101 8/17/2009 0.70909 - 1,710 1.87 G-3607 254156080172101 7/17/2009 0.70916 - 978 0.47 G-3608 254108080170601 7/27/2009 0.70911 - 814 1.47 G-3609 254005080171601 7/30/2009 0.70913 - 2,450 1.12 G-3611 253710080184701 8/12/2009 0.70917 0.70917 1,130 0.19 G-3699 252652080244301 8/20/2009 0.70916 0.70915 7,320 0.47 G-3701 253214080224601 8/7/2009 0.70910 - 4,040 1.66 G-3702 253334080213601 8/6/2009 0.70916 0.70916 2,410 0.47 G-3855 252650080252701 8/18/2009 0.70913 - 5,880 1.12 G-3856 252650080252401 8/18/2009 0.70914 0.70915 1,500 0.95
- Selected samples were rerun as a quality assurance check.
18 (18O) in parts per thousand (per mil). Differences in the exception of results from wells G-901, G-3601, and G-3856, 2H and 18O composition in water samples can be evaluated which were outliers (fig. 29A). The resulting equation is graphically to differentiate between water of various sources (Richter and Kreitler, 1993, p. 28). Following the techniques 2H = (0.0013)x-10.97, r2 = 0.90, n=32, (3) similar to those applied by Schmerge (2001) in southwestern Florida, a linear regression of the results of 46 groundwater where x is the chloride concentration in milligrams per liter.
and surface-water samples with chloride concentrations Using the same set of sample results, an LSWML expressing less than 300 mg/L was used to infer an LEL that follows 2H as a function of 18O is the relation:
2H = (5.89) 18O+2.69, r2 = 0.97, n=32, (4)
H = (5.43) O+1.35, r = 0.98, 2 18 2 (2)
The 2H and 18O in samples, as well as the GMWL, The equation for this line is similar to other LEL, and LSWML, are presented in figure 29B. The 2H determinations of evaporation lines in Florida (Kendall and and chloride concentrations in samples and the LSWML are Coplen, 2001; Schmerge, 2001; Florea and others, 2010). presented in figure 29A. The intersection of the LEL and the A local saltwater mixing line (LSWML) was estimated GMWL provides an estimate of the weighted mean isotopic by performing a linear regression on groundwater samples that composition of annual precipitation in the catchment (Gibson had a chloride concentration greater than 300 mg/L, with the and others, 1993, p. 81). For this study area, the LEL intersects
Characterization and Distribution of Saltwater in the Biscayne Aquifer 37 A
10 FKS 7, G-896, G-3603, G-3606, G-3600 5 G-3607, G-3608, G-3610, G-3 G-3611, G-3700, G-3885 699 G-3 699 y = 0.0013x - 10.97 G-9 01 R² = 0.90 FK S4 0
604 S8 Delta deuterium, per mil G-3 G-3 S4 FK 601 FK S8 EXPLANATION FK G-3 Local saltwater mixing G-3 704 line (LSWML)
-5 856 G-3 615 Surface-water sample G-3 G-1 615 264 Groundwater sample G-9 Replicate groundwater sample
-10 G-9 39 39 Samples used to create LSWML G-3 605 F-279, G-3602, G-3 G-3855, G-3946D 701
-15 F-45 G-3609, G-3698, G-894 G-3702, G3705
-20 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 Chloride concentration, in milligrams per liter B
10 G-3600 C9 Canal near NE 17 Ave EXPLANATION 5 C5 Canal at NW 32 Ct, C1 Canal at G-3702, Global meteoric mixing G-3699 G-3601, G-3604 C2 Canal 150 ft line (GMML) (Craig, 1961)
FKS 8 upstream of S-22, Local saltwater mixing Card Sound Road Canal 7.7 mi upstream C2 Canal at G-3608 line (LSML) 0 from mouth, F-279, G-1264, G-3602, VSMOW Local evaporation line Delta deuterium, per mil G-3607, G-3855, G-3856, G-901 (LEL) and G-3946D Canal at G-3698, Canal, G-3608 Vienna standard mean ocean C100A at SW 72 Ave, water (VSMOW)
-5 Florida City Canal FKS4, G-896, Surface-water sample at G-3699 and G-3704 Groundwater sample G-3606, G-3610, Replicates groundwater sample
-10 G-3700, G-3701 C8 Canal at G-3601, FKS-7, G-939, G-3603, G-3605, C2 canal replicates G-3609, G-3611, G-3615, G-3698, G-3702, G-3705, G-3608 and G-3885 F-45 C-2 canal
-15 G-3608 replicates Weighted mean isotopic composition of annual precipitation in the catchment G-894, August 2009, September 2010
-20
-4 -3 -2 -1 0 1 2 Delta oxygen-18, per mil Figure 29. Relations between (A) chloride concentration and delta deuterium and (B) delta oxygen-18 and delta deuterium in groundwater and surface-water samples collected during 2009-2010, Miami-Dade County, Florida.
38 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater the GMWL at respective 2H and 18O values of -16.9 and wells also have chloride concentrations ranging between
-3.37, which is almost exactly where the sample results of well 7,600 and 9,820 mg/L. The relative enrichment in heavier G-894 plot (see the Biscayne Canal section of this report). isotopes of the samples from these wells therefore is likely a The LSWML and LEL are similar, and it is difficult to result of mixing with encroaching seawater (see the Saltwater distinguish between water that has undergone evaporation in Encroachment section of this report).
canals or the Water Conservation Areas (WCAs) and water that has mixed with seawater. The slope of the LSWML is slightly closer to the slope of the GMWL than to the slope of Tritium and Uranium Concentration the LEL. All of the samples used to determine the LSWML Tritium concentration in samples in the study area came from groundwater wells, but a large proportion of the averaged 1.3 TU, and had a standard deviation of 0.8 TU, samples used to create the LEL were from canals that begin with the exception of the samples from Card Sound Road at, or within, the WCAs and (or) Lake Okeechobee (fig. 1).
Canal 7.7 mi Upstream from Mouth, wells G-1264, G-3698, This surface water may have undergone evaporation while G-3699, G-3855, and G-3856, and in one of the two samples it resided in the canals, WCAs, or the other surface-water from well FKS4, which had tritium concentrations ranging features. Once the water enters an aquifer, evaporation is from 4.1 to 53.3 TU and averaging 12.4 TU. These sites are all curtailed or ceases; therefore, the groundwater may have located within 8.5 km of the Turkey Point Nuclear Power Plant undergone less evaporation than the water sampled from Cooling Canal System (CCS) (see the Turkey Point Nuclear the canals. Even so, the equations of the LEL and LSWML Power Plant Cooling Canal System section of this report).
determined herein are similar. This similarity may be because Dissolved uranium ranged from 0.852 to 8.83 micrograms of the considerable amount of interaction between the surface-water and groundwater systems in the study area. per liter (µg/L) in samples from the surface-water sites C1 Canal The 2H and 18O composition of some canal samples may at G-3702, Canal at G-3698, and Florida City Canal at G-3699 reflect greater proportions of base flow from groundwater, and in samples from wells G-3615, G-3698, G-3699, G-3700, whereas some well samples may reflect greater proportions G-3701, G-3702, G-3855, and G-3856 (appendix 2, table 2-1),
of recharge to the aquifer from canals. The sample from Card which are located in a 6.1-km2 area in southeastern Miami-Sound Road Canal 7.7 mi Upstream from Mouth (fig. 29B) Dade County near the CCS. The greatest dissolved uranium indicates an isotopic composition that is more similar to that concentrations were 8.83 and 6.25 µg/L in wells G-3699 and of many of the groundwater samples (shifted to the left of G-3701, respectively (appendix 2, table 2-1). All samples from the LEL) than to the isotopic compositions of most other surface-water sites or wells located outside of the 6.1-km2 area canal samples. The Card Sound Road Canal begins as a small had dissolved uranium concentrations less than 0.656 µg/L; the ditch not far upstream from where the sample was collected, average concentration was 0.181 µg/L +/- 0.216 µg/L. Samples and most of the flow in the canal is sustained by base flow from many of the sites in the 6.1-km2 area also indicate tritium from groundwater. concentrations ranging from 4.1 to 53.3 TU. The site Card The range of 2H in groundwater samples was -16.9 to Sound Road Canal 7.7 mi Upstream from Mouth and wells 6.50 per mil, and 2H in surface-water samples ranged from FKS4 and G-1264 had elevated tritium concentrations, but were
-9.41 to 3.89 per mil. The range of 18O in groundwater not sampled for uranium.
samples was -3.38 to 0.57 per mil. In surface-water samples, this range was -2.00 to 0.36 per mil. The samples from well G-3600 indicated greater 2H and 18O values than any of Tritium/Helium-3 Age Dating the other samples (fig. 29B). This finding may stem from a 3 H/3He age dating can be used to date water younger combination of a greater extent of evaporation, and a greater than about 40 years. Generally tritium and helium are non-proportion of seawater in the samples from this well than in other samples. Water samples from C2 Canal at G-3608 and reactive and are unaffected by groundwater chemistry or by C2 Canal 150 ft Upstream of S-22 on the Snapper Creek anthropogenic contamination. 3H/3He age dating uses the Canal and C9 Canal near NE 17 Ave on the Snake Creek known half-life of tritium and the 3H/3He ratio measured in Canal appear to have undergone more evaporation relative to water samples to estimate an age of the water. Although some the other canal samples (fig. 29B). Wells G-3608 and G-901, mixing of younger and older water may occur as water flows which are near the Snapper Creek Canal, also have sample through the ground, the simplest and most common transport results that plot close to those from the Snapper Creek Canal assumption in ground-water age dating is to assume piston (fig. 29B). This finding may indicate that surface water within flow, which assumes that the constituent concentration was the Snapper Creek Canal has contributed a large proportion of not altered by transport processes (such as mixing or disper-the water sampled in these wells (see the Snapper Creek Canal sion) from the point of entry to the measurement point in the section of this report). aquifer (Rupert and Plummer, 2004, p. 9). Within the study The water samples collected from wells FKS8 and area, however, intruding saltwater has almost certainly mixed G-3699 had greater 2H and 18O values than did the samples with freshwater in the aquifer and/or canals. Saltwater from from the canals adjacent to these wells, which are the Card recent intrusion events may have mixed with saltwater from Sound Road and the Florida City Canals, respectively. These previous intrusion events. Therefore, although the piston-flow
Characterization and Distribution of Saltwater in the Biscayne Aquifer 39 ages are provided, the age likely represents a mixture of water Estimates of Recharge Temperature Based on of various ages.
Dissolved Gases After corrections were applied (appendix 10), the analytical ages of water in the study area ranged from Recharge temperature is the temperature of groundwater 6 +/- 0.5 to 46 +/- 2.3 years (table 5). Actual ages of water are after it is isolated from the soil atmosphere (Plummer and likely less precise than the analytical ages provided (table 5) others, 2003). Recharge temperatures are determined using because of uncertainties in the 3He/4He ratio, recharge the assumptions that the gases dissolved in the groundwater temperature, and the amount gas fractionation. Therefore, originate from air-water solubility as described by Henrys interpreted piston-flow ages are provided (table 5) that Law and that excess air is introduced into the aquifer during consider these factors. Many of the wells sampled have water recharge from air-bubble entrainment as a result of a rise in younger than 1970, which could be caused by saltwater the water table (Hinkle and others, 2010, Aeschbach-Hertig intrusion events occurring after 1970 or mixing of younger and others, 1999, 2000). Dissolved nitrogen (N2) and argon freshwater with older saltwater. The interpreted piston-flow (Ar) concentrations are used to evaluate recharge temperatures ages of water samples that had a chloride concentration of (Aeschbach-Hertig and others, 1999; 2000; Busenberg and about 1,000 mg/L or greater were generally older than those others, 1993; Heaton, 1981; and Heaton and Vogel, 1981). The samples with a chloride concentration of less than about accuracy of this method is typically +/- 0.5 oC using laboratory 1,000 mg/L. The ages of water samples that had a chloride standards (Plummer and others, 2003). Uncertainty in the concentration of about 1,000 mg/L or greater correspond to nitrogen/argon (N2/Ar) recharge temperatures can result from a period during which droughts were more frequent and of uncertainties in recharge elevation, presence of excess N2 longer duration (fig. 30). The relation between the ages of from denitrification of NO3- (degassing), and the presence saltwater samples and drought periods (fig. 30) concurs with of excess air in samples. In Miami-Dade County near the historical observations that the greatest extents of saltwater coast, where samples were collected, the water table gener-intrusion generally occurred during droughts, when fresh ally varies seasonally and geographically by only a few feet groundwater heads are low and saltwater may encroach along (Lietz and others, 2002), so uncertainty in recharge elevation the base of the aquifer or flow inland in canals, rivers, or tidal is negligible. Denitrification can affect the determination of marshes (see Relation of Urban Development to Saltwater recharge temperatures and excess air in samples. The amount Intrusion section of this report). of excess N2 from denitrification was estimated from the solubility of Ar using an iterative procedure.
Sulfur Hexafluoride Age Dating The dissolved gas concentrations of argon, carbon dioxide, methane, nitrogen, and oxygen, were determined for 23 samples Sulfur hexafluoride (SF6) can be used to date groundwater from selected sites (appendix 2, table 2-2; U.S. Geological that is younger than 30 years (Busenberg and Plummer, 2000). Survey, 2011i) to determine the recharge temperatures of SF6 concentrations in 40 samples ranged from 0.33 to 136 parts individual samples. Sample results indicate a relation between, per thousand total volume (pptv) (appendix 2, table 2-4). Ages N2/Ar recharge temperature, seasonal changes in air temperature could not be determined for most of these samples, however, and water level, and the salinity of samples (figs. 31A and 31B, because the samples contained greater amounts of SF6 than table 7). The recharge temperatures of most of the samples would result from equilibrium with the expected atmospheric with chloride concentrations greater than or equal to about concentration. Samples containing the highest concentrations 1,000 mg/L (samples from the seaward side of the saltwater of SF6 generally were from surface-water monitoring sites or interface) indicated a range in the N2/Ar recharge temperature monitoring wells near electrical power distribution facilities. of 23.8 - 25.4 °C, which is similar to the air temperatures that These sites include C2 Canal 150 FT Upstream of S-22, occur when aquifer water levels are at minimum levels, and Florida City Canal at G-3699, C2 Canal at G-3608, and the potential for saltwater intrusion is greatest (The Weather Canal at G-3698 and wells F-45 and G-3700 (appendix 2, Channel, 2013; figs. 31A and 31B, table 7).
table 2-4). Leakage of SF6 from electrical power generation The recharge temperatures of samples with chloride facilities in southeast Florida has been noted previously concentrations less than about 1,000 mg/L (the freshwater side (U.S. Environmental Protection Agency, 2000) and may account of the saltwater interface) generally indicated warmer recharge for the excess SF6 found in at least some of the samples. temperatures and, with one exception, had recharge tempera-Even where SF6 concentrations were low enough to allow tures between 25.5 - 26.8 °C. This range of temperatures corre-an estimation of age, the SF6 ages typically disagreed with sponds to average air temperatures in the second half of May the 3H/3He ages (table 6). Only the near absence of SF6 in when rainfall and water levels in the aquifer typically begin to some samples indicates that water at these locations may be increase (figs. 31A and 31B). The samples from wells G-3609 older than elsewhere. Samples from wells G-3600, G-3601, and G-3855 were exceptions to these general relations.
G-3603, G-3609, and G-3701 had the least amounts of SF6 Water samples that have N2/Ar recharge temperatures (0.33 to 1.21 pptv; appendix 2, table 2-4). Samples from wells indicative of the end of the dry season when aquifer water G-3600, G-3601, and G-3701 also had too little tritium for levels are low, also have interpreted 3H/3He piston-flow ages 3
H/3He age dating. that correspond to a period of frequent droughts (see the
Table 5. Results of tritium/helium-3 age dating of water samples collected during 2009-2010 in Miami-Dade County, Florida.
[?, could not be determined; , standard deviation; TU, tritium unit; %, percent; <, less than; ~, about; -, no data]
4He/ Analytical age, Analytical age, cor- Interpreted Terrigenic Tritium 4He Ne Ne 2 uncorrected for ter- rected for piston-flow Comments USGS station Sample He Local identifier Ratio1 rignic helium3 terrignic helium age4 number date TU +/-1 % years +/-1 years +/-1 year (TU) (years) (years)
C2 CANAL AT 254108080170600 7/28/2009 2.08 0.13 2.6 4.8 0.5 -2.95 1 0.1 - - - Result not used because of gas fractionation G-3608 and direct exposure to air.
F-279 255315080111501 8/21/2009 0.67 0.12 31.5 7.5 4.2 17.39 - - 45 3.0 < 1970 Result corrected for terrigenic helium.
G-3600 255626080093201 8/12/2010 0.25 0.04 13.6 -7.7 -1.8 19.87 - - - - - Negative Ne indicates gas fractionation, age is questionable.
G-3601 255358080114101 8/17/2009 -0.05 0.1 32.3 9.7 3.3 15.89 - - - - - Too little tritium to age date.
G-3607 254156080172101 7/17/2009 1.68 0.09 19.5 17.4 1.1 -0.64 16 0.6 - - ~ 1993 Result without terrigenic helium correction.
G-3608 254108080170601 7/27/2009 1.66 0.1 5.8 8.6 0.7 -3.95 12 0.5 - - ~ 1997 Result without terrigenic helium correction.
Possible gas fractionation.
G-3609 254005080171601 7/30/2009 0.74 0.08 43.6 19.1 2.3 14.97 - - 34 1.8 1970s Result corrected for terrigenic helium, age uncertain because of very low tritium.
G-3611 253710080184701 8/12/2009 1.55 0.11 26.1 24.3 1.1 -1.68 29 1.1 - - late 1970s Result without terrigenic helium correction, early 1980s age uncertain because of very low tritium.
G-3698 252814080244101 7/20/2010 5.73 0.11 34.6 9.2 3.8 17.73 - - 24 0.3 ~ 1986 Result corrected for terrigenic helium.
G-3699 252652080244301 8/20/2009 45.8 0.91 24.3 4.6 5.3 15.3 - - 28 0.3 ~ 1981 Result corrected for terrigenic helium.
G-3701 253214080224601 8/7/2009 0 0.11 33.1 18 1.8 9.17 - - - - - Too little tritium to age date.
G-3702 253334080213601 8/6/2009 0.74 0.1 31.7 20.4 1.6 6.02 - - 46 2.3 < 1970 Result corrected for terrigenic helium.
G-3704 254822080125501 7/21/2010 0.54 0.04 71.7 11.4 6.3 33.85 - - 29 1.2 late 1970s Result corrected for terrigenic helium age early 1980s uncertain because of low very low tritium.
G-3705 255625080094901 8/12/2010 1.49 0.05 15.4 4.2 3.7 9.13 - - 30 0.5 ~ 1980 Result corrected for terrigenic helium.
G-3855 252650080252701 8/18/2009 17.8 0.36 20.3 8.1 2.5 9.01 - - 26 0.3 ~ 1983 Result corrected for terrigenic helium.
(Trigger)
G-3856 252650080252401 8/18/2009 4.59 0.13 5.4 4.9 1.1 -0.26 17 0.3 - - ~ 1992 Result without terrigenic helium correction.
(Sentinel)
G-894 255350080105801 8/14/2009 1.43 0.15 10 13 0.8 -4.62 6 0.5 - - ~ 2003 Result without terrigenic helium correction.
Possible gas fractionation.
G-896 254107080165201 8/4/2009 1.68 0.06 9.8 13.4 0.7 -5.24 11 0.3 - - ~1998 Result without terrigenic helium correction.
Possible gas fractionation.
G-939 253652080183701 8/27/2009 1.08 0.12 18.6 10.5 1.8 5.47 - - 26 1.7 ~1983 Result corrected for terrigenic helium.z 1
Samples indicating a 4He/Ne ratio of less than 1 may have been affected by gas fractionation.
2 40 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Corrections for terrigenic helium were applied to samples that indicated that terrigenic helium was greater than 5 percent.
3 Analytical age is based on precision of analysis but this precision does not consider other factors such as uncertainties in the recharge temperature, 3He/4He ratio, and gas fractionation.
4 Interpreted piston-flow age considers some uncertainties in the analysis, but does not consider the mixing which likely occurred as saltwater intruded the aquifer.
Sources of Saltwater in the Biscayne Aquifer 41 100,000 G-3699 G-939 G-3704 (~1981) (~1983)
F-279 (late 1970s, G-3855 10,000 Chloride concentration,
(< 1970) early 1980s) (~1983)
G-3609 G-3698 1,000 G-896 (1970s) G-3705 (~1986)
G-3702 (~1980) (~1998)
G-3856
(<1970) in milligrams per liter
(~1992) 100 G-3611 G-3608 G-894 (late 1970s, (~1997) (~2003) early 1980s) G-3607 10 1938 1943 1949 1960 1970 1980 1984 (~1993) 2000 to to to to to to to 1939 1946 1957 1963 1977 1982 1990 1 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year EXPLANATION 1985 Drought period and year(s)
Analytical age of water sample, chloride G-3705 concentration about 1,000 mg/L and identifier.
(~1980) Interpreted piston-flow age is in parentheses Analytical age of water sample, chloride G-894 concentration < about 1,000 mg/L and identifier.
(~2003) Interpreted piston-flow age is in parentheses.
Dashed where gas fractionation may have affected sample
~ Approximately Figure 30. 3H/3He interpreted piston-flow ages of water samples collected during 2009-2010 in the Miami-Dade County area and dates of documented droughts in south Florida. [mg/L, milligrams per liter]
Tritium/Helium-3 Age Dating section of this report), whereas Relict Seawater from Previous Sea-Level High those that have warmer recharge temperatures generally Stands have younger ages that correspond to a period during which droughts were infrequent (fig. 30). Previous research has Results of this study indicate that saltwater sampled in shown that saltwater usually intrudes when water levels in the Biscayne aquifer in eastern and southern Miami-Dade the aquifer and in canals are at minimum levels, particularly County is not relict seawater from previous sea-level high during droughts (Cross and Love, 1942, p. 501). Minimum stands. Most of the interpreted piston-flow ages indicate that water levels are usually reached near the end of the dry season the water sampled was too young to be considered relict from April to early May, so the observed relation between seawater. Recent changes in the bulk conductivity of EMI recharge temperatures, water levels in the aquifer, and salinity logs and the chloride concentrations in samples collected from of samples is not surprising. This relation assumes piston these wells indicate that the water in these wells is probably flow, however, which may not be the best assumption since not relict seawater. The chloride concentrations in water saltwater and freshwater likely mixed in the aquifer. sampled from these wells has varied by between 325 mg/L and 2,732 mg/L during the few decades that the wells have been monitored. Changes in salinity occurring during such short Sources of Saltwater in the Biscayne periods of time indicate that the transmissivity of the aquifer at these locations is likely sufficient to have allowed freshwater Aquifer to replace any relict saltwater during the last Pleistocene low stand.
The Biscayne aquifer has several potential sources of The changes in chloride and bulk resistivity at monitoring saltwater or pathways through which saltwater can intrude. It wells G-3601 and G-3701, open to the Pinecrest Sand is important to differentiate between these sources or pathways Member of the Tamiami Formation, are likely too large to be because if they are misconstrued, the corrective measures due to relict seawater, even though the transmissivity of this implemented to prevent saltwater intrusion in affected areas geologic unit is very low relative to transmissivities of most could fail to address the actual causes. Geochemistry, TSEMIL of the geologic units in the Biscayne aquifer. The chloride datasets, TEM soundings, long-term chloride concentration concentration in well G-3601 (fig. 32B) increased from 660 to data, and the 2001 HEM survey were used to identify the 1,400 mg/L during 1999 to 2011. The bulk conductivity probable sources and ages of saltwater in the aquifer at various of EMI logs from well G-3601 (figs. 32A and 32B) gradu-locations within the study area. ally increased from about 42 to 87 mS/m during 1996 to
42 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 6. Differences between ages determined using SF6 and tritium/helium-3 age dating for samples collected in Miami-Dade County, Florida, during 2009-2010.
[/, denotes ratio; C, contaminated with excess SF6; --, no data]
Difference Analytical between Average piston- tritium/ analytical Local USGS station Sample flow model SF6 helium-3 tritium/
Comments identifier number date recharge age, piston flow helium-3 in years 1 age, in age and years2 SF6 age, in years C2 CANAL 254108080170600 7/28/2009 C 1 -- Tritium/helium-3 age not used because of AT G-3608 gas fractionation and exposure to air F-279 255315080111501 8/21/2009 23.6 45 21 --
G-3600 255626080093201 8/12/2010 27.6 -- -- Tritium/helium age likely affected by gas fractionation G-3601 255358080114101 8/17/2009 36.4 -- -- Tritium content too low for tritium/
helium-3 age dating G-3607 254156080172101 7/17/2009 C 16 -- --
G-3608 254108080170601 7/27/2009 C 12 -- --
G-3609 254005080171601 7/30/2009 29.8 34 4 --
G-3611 253710080184701 8/12/2009 14.9 29 15 --
G-3698 252814080244101 7/20/2010 C 24 -- --
G-3699 252652080244301 8/20/2009 C 28 -- --
G-3701 253214080224601 8/7/2009 32.6 -- -- Tritium content too low for tritium/
helium-3 age dating G-3702 253334080213601 8/6/2009 4.10 46 42 --
G-3704 254822080125501 7/12/2010 24.3 29 5 --
G-3705 255625080094901 8/12/2010 23.1 30 7 --
G-3855 252650080252701 8/18/2009 2.90 26 23 --
G-3856 252650080252401 8/18/2009 C 17 -- --
G-894 255350080105801 8/14/2009 5.90 6 0 --
G-896 254107080165201 8/4/2009 C 11 -- --
G-939 253652080183701 8/27/2009 17.9 26 8 --
1 Because so many of the samples were contaminated with excess amounts of SF6, and because the ages determined even for those samples with dateable amounts of SF6 were younger in every instance than the ages determined using tritium-helium-3 age dating, the SF6 ages are not reliable and should not be used.
2 Analytical age is based on precision of analysis but this precision does not consider other factors such as uncertainties in the recharge temperature, 3He/4He ratio, and gas fractionation.
2011. If changes of this magnitude occurred in a little more The SF6 concentrations in samples from wells G-3601, than one decade, then the freshwater flow during the last G-3602, G-3604, G-3605, and G-3701 (0.33 to 5.92 pptv) sea-level low stand should have been sufficient to remove (appendix 2, table 2-4) indicate that the interpreted piston-any relict saltwater in this part of the aquifer. EMI logs from flow age of water in these wells is more recent than 1952, but well G-3701 show changes in bulk conductivity within the potential contamination by excess SF6 (table 6) renders the Biscayne aquifer, and below it, in the Pinecrest Sand Member result inconclusive.
(fig. 33A and 33B). The open interval of this well begins 3.3 m below the base of the Biscayne aquifer. Changes in bulk resistivity in the Biscayne aquifer at well G-3701 are much Historical Leakage of Saltwater from Canals greater than those in the Pinecrest Sand Member. Nonetheless, during 2002 to 2011, the chloride concentration of water Some of the existing saltwater in the Biscayne aquifer samples from well G-3701 (fig. 33B) varied from 355 to near primary drainage canals such as the Biscayne, Miami, 680 mg/L, which is likely sufficient variation to indicate that Tamiami, and Card Sound Road Canals may have been freshwater replaced any relict saltwater within the Pinecrest caused by the flow of saltwater inland prior to the installation Sand Member. of salinity control structures. Between May and July 1945,
Sources of Saltwater in the Biscayne Aquifer 43 Table 7. Average recharge temperature and chloride concentration of surface-water and groundwater samples collected in Miami-Dade County, Florida during 2009-2010.
[°C, degrees Celsius; mg/L, milligrams per liter]
Average recharge tem- Chloride water, Local identifier USGS station number Sample date perature (°C) filtered * (mg/L)
C2 CANAL 150 FT 254012080170200 12/15/2009 26.6 44.7 UPSTREAM OF S-22 C2 CANAL AT G-3608 254108080170600 12/14/2009 26.8 42.5 C2 CANAL AT G-3608 254108080170600 7/28/2009 29.6 41.2 F-279 255315080111501 8/21/2009 25.3 3,480 G-3601 255358080114101 8/17/2009 24.7 1,270 G-3607 254156080172101 7/17/2009 25.9 58.2 G-3608 254108080170601 12/15/2009 26.5 158 G-3608 254108080170601 7/27/2009 26.5 173 G-3609 254005080171601 12/17/2009 25.4 1,220 G-3609 254005080171601 7/30/2009 26.4 1,180 G-3611 253710080184701 8/12/2009 26.6 175 G-3615 253024080231001 12/16/2009 24.6 3,600 G-3698 252814080244101 7/20/2010 24.7 1,200 G-3699 252652080244301 8/20/2009 24.5 8,910 G-3700 253027080234701 12/16/2009 25.7 23.2 G-3701 253214080224601 8/7/2009 25.9 832 G-3702 253334080213601 8/6/2009 25.1 997 G-3704 254822080125501 7/21/2010 24.8 6,190 G-3855 252650080252701 8/18/2009 26.8 3,760 G-3856 252650080252401 8/18/2009 25.7 553 G-894 255350080105801 8/14/2009 25.8 18.0 G-896 254107080165201 8/4/2009 25.5 211 G-939 253652080183701 8/27/2009 23.8 3,410 Samples with a chloride concentration of about 1,000 mg/L or greater are highlighted in pink.
saltwater with chloride concentrations ranging from 1,100 to others (2012) identified saltwater at the base of the Biscayne 26,000 ppm was sampled at distances ranging from 4.7 to aquifer, extending about 15 km inland, beneath the Card 20 km inland in most of the primary canals in Miami-Dade Sound Road Canal. This saltwater extends farther inland in the County (Parker and others, 1955, p. 633 and 680). Samples area between U.S. Highway 1 and the Card Sound Road Canal from wells and geophysical measurements made near than it does to the west. Fitterman and others (2012) concluded these canals in the present study indicate elevated chloride that this saltwater likely leaked from the Card Sound Road concentrations and bulk conductivities and lower than normal Canal and FEC borrow ditches. During the drought of resistivity in these areas. 1943-46 (fig. 4), saltwater with a chloride concentration of 26,000 ppm was sampled in the Card Sound Road Canal as far inland as 20.0 km (Parker and others, 1955, p. 680, fig. 188).
The Card Sound Road Canal and FEC Railway In June or July 1945, the FEC railway borrow ditches were Borrow Ditches strongly contaminated [with saltwater] to a distance less than 6 mi from Florida City, and it was considered possible that Historical saltwater intrusion near the Card Sound Road ground-water contamination continued even farther inland Canal and Florida East Coast (FEC) railway borrow ditches (Parker and others, 1955, p. 682). A 1955 map shows saltwater likely contributed to the saltwater detected by the 2001 in the Biscayne aquifer extending about 18-19 km inland HEM survey (Fitterman and others, 2012). Fitterman and beneath the Card Sound Road Canal and the FEC railway
44 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater B
1.2 Average daily maximum water level, in meters 1.1 1.0 0.9 0.8 0.7 0.6 Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Month A
30 25 29 DRY SEASON WET SEASON 28 Range in recharge temperatures of most water 27 samples with < ~1,000 mg/L chloride 20 Average monthly precipitation, centimeters 26 Temperature, degrees Celsius 25 Range in recharge temperatures of most water samples with > ~1,000 mg/L chloride 24 15 23 22 21 10 20 19 18 5 17 16 15 0 Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Month EXPLANATION Average monthly precipitation Range in recharge temperatures of most samples with chloride concentrations greater than or equal to about 1,000 mg/L Range in recharge temperatures of most samples with chloride concentrations less than about 1,000 mg/L Polynomial regression of daily average daily air temperature Delineates the period of minimum average maximum daily water levels, and corresponding daily average air temperatures Average maximum daily water level Daily average air temperature Figure 31. (A) Average monthly precipitation, daily average air temperature in Miami, Florida, and the range of recharge temperatures of water samples collected from the Biscayne aquifer in Miami-Dade County, Florida, and (B) average of daily maximum water levels in selected wells open to the Biscayne aquifer during October 1, 1974, to September 30, 2009. [<, less than; mg/L, milligrams per liter; , greater than or equal to]
Sources of Saltwater in the Biscayne Aquifer 45 A
0 EXPLANATION G-3601 5 electromagnetic induction logs 10 1/10/1996 5/09/1996 15 4/21/1997 2004 2003 5/1998 Depth, in meters below land surface 20 4/12/1999 4/2000 4/11/2001 25 5/13/2002 4/29/2003 30 2009 2010 2011 4/22/2004 4/25/2005 35 09/13/2006 6/19/2007 40 5/05/2008 4/30/2009 45 4/21/2010 4/26/2011 50 2011 55 1996 Screened 0 10 20 30 40 50 60 70 80 90 100 56.4 to 57.9 meters Bulk conductivity, in millisiemens per meter B
1,500 95 90 1,400 85 1,300 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 80 1,200 75 1,100 70 65 1,000 60 900 55 800 50 EXPLANATION 700 Chloride concentration 45 Bulk conductivity 600 40 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 32. (A) Time-series electromagnetic induction log (TSEMIL) dataset and (B) chloride concentrations in samples from monitoring well G-3601 and bulk conductivity measured at a depth of 56.1 meters, Biscayne aquifer, Miami-Dade County, Florida.
46 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3701 electromagnetic induction logs 4/4/2001 5 Variations in bulk conductivity are common near the land surface. One possible explanation 5/15/2002 is difference in the water temperature occurring 4/24/2003 near the land surface 4/20/2004 Depth, in meters below land surface 4/14/2005 4/18/2006 10 6/13/2007 4/29/2008 In the 11-year period, bulk conductivity has 5/05/2009 varied by as much as 50 millisiemens per 4/7/2010 meter in the depth interval 12 to 12.5 meters 15 4/6/2011 20 Estimated depth of base of Biscayne aquifer Other than the first log, collected in 2000 shortly after the well was drilled, there has been little variation in bulk conductivity Screened measured below a depth of 20.5 meters. 23.8 to 25.3 meters 25 0 20 40 60 80 100 120 140 Bulk conductivity, in millisiemens per meter B
800 55 700 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 600 50 500 400 45 300 EXPLANATION Chloride concentration Bulk conductivity 200 40 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 33. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3701 and bulk conductivity measured at a depth of 24.0 meters, Biscayne aquifer, Miami-Dade County, Florida.
Sources of Saltwater in the Biscayne Aquifer 47 borrow ditches (Parker and others, 1955, p. 709, fig. 200). Turkey Point Nuclear Power Plant Cooling Canal The inland extent of the saltwater described by Fitterman and System others (2012) is about 1.5 km less than the extent mapped in the Biscayne aquifer by Parker and others (1955, p. 709, The cooling canal system (CCS) of the Turkey Point fig. 200), but is about 6 and 3 km inland of wells FKS4 and Nuclear Power Plant east of Florida City (fig. 8) was FKS8, respectively. The ion exchange front is, therefore, constructed during the early 1970s and contains hypersaline well inland of these wells. This mapped extent of saltwater water (Janzen and Krupa, 2011). This hypersaline water helps to explain why the Ca/(HCO3 + SO4) molar ratio in may be contributing to saltwater encroachment in this area water, sampled from these wells, is less than 1 and concen- (Hughes and others, 2010). Water in the cooling canals is trations of major ions typically plot near the theoretical reported to have tritium concentrations at least two orders of freshwater/seawater mixing line (figs. 19, 21, 23, 25, 26). magnitude above surrounding surface and groundwater and Results indicate that little or no ion exchange is taking place [tritium] therefore [is] considered a potential tracer of waters at these locations. from the CCS (Janzen and Krupa, 2011, section 2, p. 8).
The tritium concentration of samples collected from sites located within 8.5 km of the CCS ranged from 4.1 to 53.3 TU Miami and Tamiami Canals and averaged 12.4 TU, whereas the tritium concentration Surface water in the Miami Canal at USGS monitoring of samples collected farther away from the CCS averaged station Miami Canal at Water Plant (appendix 1) (U.S. 1.3 TU (appendix 2, table 2-3) (see the Tritium and Uranium Geological Survey, 2011f), 4 km upstream of salinity control Concentration section of this report). Saltwater intrusion is a structure S-26, had become saline (335 mg/L chloride recent occurrence at most of the groundwater monitoring wells concentration) during the drought of 1970 to 1977, and the (figs. 18, 19, 21-26) within 8.5 km of the CCS, except at wells chloride concentration of water in wells adjacent to this canal FKS4 and FKS8 near the Card Sound Road Canal (see the had increased (fig. 13). The subsequent decrease in chloride Card Sound Road Canal section of this report). No samples concentrations in wells near the Miami Canal and west of were collected from the CCS or wells within it as part of the salinity control structure S-26 (fig. 13) may be the result of current study to detect any possible influxes of CCS water into the dissipation of saltwater that had leaked from the canal. the aquifer; however, monitoring wells were installed in 2010 The area of probable historical canal leakage is indicated in adjacent to the CCS for other studies and these wells are being figure 17. A 3H/3He age-dating sample could not be obtained monitored using electromagnetic induction logging.
from well G-1351 to determine if the saltwater entered the aquifer during the 1970 to 1977 drought. The major and trace Recent Leakage from Canals ion geochemistry of samples from wells G-3604 and G-3605 near the Miami and Tamiami Canals (fig. 8) indicate little or Although salinity control structures have been installed no ion exchange. The episodes of saltwater intrusion during in most of the tidal canals, the leakage of saltwater through the droughts of 1938-1939 and 1970-1977 (figs. 4 and 13) the porous rock of the Biscayne aquifer and around existing may have filled the ion-exchange sites of the rocks and sedi- salinity control structures is documented (Parker and ments in the aquifer at these locations. The extent of saltwater others, 1955; Kohout and Leach, 1964; Leach and Grantham, intrusion in 1955 (fig. 8), 1969 (Renken and others, 2005a), 1966). Kohout and Leach (1964) reported that any saltwater and 1984 (Klein and Waller, 1985) was inland of both of these upstream of the salinity control structures could be driven wells, particularly well G-3604. into the aquifer when freshwater heads in the canals upstream of these structures increased. Monthly measurements of salinity collected by the Miami-Dade County Permitting, C-111 Canal Environmental, and Regulatory Affairs (M-D PERA) during A narrow finger of conductive groundwater extends at 1988 to 2010 (appendix 11) show influxes of saltwater in least 2.7 km inland along the C-111 Canal (fig. 8) (Fitterman many of the canals upstream of the salinity control structures.
and Deszcz-Pan, 1998, 2002). This finger is likely related These measurements at stations BL03, BS04, CD02, GL03, to the leakage of saltwater from the C-111 Canal occurring LR06, PR03, MI03, MW04, and SP04, located in the Black between 1965 when the canal was installed and 1969 when Creek, Biscayne, Cutler Drain, Goulds Canal, Little River, salinity control structure S-197 was installed. Leakage of Princeton, Military, Mowry, and Snapper Creek Canals, saltwater from the C-111 Canal peaked in 1965 when tidal respectively (fig. 8), have detected influxes of saltwater inundation from Hurricane Betsy caused saltwater with a upstream of the water control structures in these canals.
chloride concentration of 10,000 mg/L to flow as far inland The occurrences have ranged from rare influxes of water as about 3 km upstream from salinity control structure with salinity between 0.5 and 1.4 PSU at station SP04 in S-18C (Meyer, 1974, p. 28). Meyer (1974, p. 30a) also the Snapper Creek Canal, to frequent influxes of water with reported the occurrence of saltwater between 1970 and 1971 a salinity of between 15 and 32 PSU at station BS04 in the in the C-109 and C-110 Canals about 3 to 4 km north of the Biscayne Canal (appendix 11). This saltwater may be leaking C-111 Canal. into the aquifer in some areas. Moreover, many existing
48 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater monitoring-network wells are in the right-of-way of local saltwater had been detected near the northern end of the Card canals. A landward bias may exist in the assessment of the Sound Road Canal (Parker and others, 1955, p. 680) about inland extent of saltwater in the Biscayne aquifer if (1) these 5 km farther inland than in 2009. Canal levels in the area were canals are leaking saltwater, (2) there are insufficient data lower during previous droughts than in 2009. For example to define the inland extent of saltwater in areas away from during the drought of 1971, groundwater levels in this area these canals, and (3) the occurrence of saltwater at these declined to about 0.3 m below sea level (Meyer, 1974, p. 24).
locations is misconstrued as originating from movement of During the 1971 drought, water levels measured in wells the saltwater front rather than canal leakage. S-196A and G-613 near Homestead and Florida City declined to levels that were 0.5 to 0.9 m lower, respectively, than in 2009 (U.S. Geological Survey, 2011f). Other factors such as Card Sound Road Canal tide magnitudes, storm surge from hurricanes, and encroach-Prior to May 2010 the Card Sound Road Canal (fig. 1) ment along the base of the aquifer also may have contributed was one of the few canals in Miami-Dade County that lacked to the inland extent of saltwater in the Biscayne aquifer near a salinity control structure. To evaluate the potential for the Card Sound Road Canal.
landward flow of saline surface water in the Card Sound A salinity control structure was installed in the Card Road Canal, salinity profiles were collected at 11 and 12 sites, Sound Road Canal just above its junction with Canal L-31E respectively, on December 5, 2008, and May 18, 2009. The in May 2010. This structure likely will reduce the flow of salt-11 salinity profiles collected on December 5, 2008, indicated water up the Card Sound Road Canal and also may increase that salinity in the canal gradually increased from 0.27 ppt freshwater head in the Biscayne aquifer in the area. In time, at a distance of 9.5 km from the mouth of the canal, to it may reduce the landward extent of saltwater in this area, 4.24 ppt at a distance of 0.64 km from the mouth of the canal but the gradual declines in chloride concentration near the (appendix 3). As water levels in the Biscayne aquifer declined Miami Canal (fig. 13) indicate that it may take a long time for to near record low altitudes by May 16, 2009, the flow in intruded water near the Card Sound Road Canal to dissipate.
the Card Sound Road Canal reversed, and saltwater from the Florida Bay flowed inland. On May 18, 2009, water at nine Biscayne Canal sites ranging from 0.64 to 11.6 km inland from the mouth was hypersaline, and salinity ranged from 43.7 to 42.3 ppt. Salinity control structure S-28 was installed in At monitoring well FKS8, which is approximately 5 m from 1960 (table 1) about 1 km west of U.S. Highway 1 to prevent the Card Sound Road Canal and 12.4 km from its mouth, the incursions of saltwater up this canal; however, water with a average salinity of canal water was 38.6 ppt. Farther inland, salinity of 20 PSU or greater has frequently been detected at distances of 13.5 and 15.9 km from the mouth of the Card at station BS04 upstream of the salinity control structure Sound Road Canal, the salinity of canal water was 0.27 and (fig. 10). This saltwater could be leaking into the Biscayne 0.18 ppt, respectively. aquifer, but it is unknown how far upstream of this station the saltwater travels. Monitoring well G-3601 is on the eastern The influx of saltwater upstream in the Card Sound Road bank of the Biscayne Canal about 5.6 km from the mouth of Canal was identified in groundwater samples from well FKS8.
the canal and about 3.8 km upstream of structure S-28. The During February 24, 2004, to March 31, 2009, the chloride TSEMIL dataset from well G-3601 (fig. 32A) indicates little if concentrations in samples from a depth of 23 m in well FKS8 any change in bulk conductivity occurring in the depth interval ranged from 4,680 to 9,480 mg/L and averaged 8,660 mg/L, 41 to 42 m, but there are changes occurring in shallower but on May 4, 2009, and May 18, 2009, chloride concentra-and deeper intervals than this interval that do not appear tions from this depth were 14,750 and 11,575 mg/L, respec- to be related. Below this depth interval, gradual increases tively (Jolynn Reynolds, Florida Keys Aqueduct Authority, in bulk conductivity indicate that the saltwater interface is written commun., 2009). Increases in chloride concentrations gradually encroaching landward. Shallower than this depth in water samples from well FKS8 also occurred in samples interval, there have been two short-term influxes of conductive from the depths 11 and 17 m. By June 29, 2009, the chloride water: the first occurring during 2003 through 2004 in the concentrations in samples from the depth 23 m had returned depth interval 18 to 32 m, and the second occurring during to near average, but the chloride concentrations in samples 2009 through 2011 in the depth interval 30 to 39 m. One from the depth intervals of 11 and 17 m were still greater than possible source of these relatively shallow influxes could be the maximums recorded at these depths prior to the influx of leakage of saltwater from the adjacent canal.
saltwater up the Card Sound Road Canal (Jolynn Reynolds, An alternative possibility is that these influxes are Florida Keys Aqueduct Authority, written commun., 2009). associated with the saltwater front. Monitoring well G-894 On May 18, 2009, saltwater in the Card Sound Road is about 1.3 km east of well G-3601. Well G-894 is open to Canal was not as far inland as the apparent extent of saltwater the depth interval (22.7 to 23.2 m) that coincides closely with in the Biscayne aquifer determined in the 2001 HEM survey the depth of the maximum bulk conductivity measured in or mapped by Parker and others (1955, p. 709). Saltwater trav- 2003 in well G-3601. Between 1959 and 1981, the chloride eled farther inland up the Card Sound Road Canal during the concentrations in samples from well G-894 ranged from previous droughts than it did in 2009. For example, in 1945, 680 to 3,600 mg/L (fig. 18). The maximum concentration
Sources of Saltwater in the Biscayne Aquifer 49 2.0 1.8 1.6 1.4 Salinity, in practical salinity units 1.2 1.0 0.8 0.6 0.4 Figure 34. Salinity of the 0.2 Snapper Creek Canal at station SP04, 1991-2010, Miami-Dade 0
County, Florida.
1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year occurred on June 4, 1962, during the drought of the early the Snapper Creek Canal (Maria Idia Macfarlane, Miami-Dade 1960s (Waller, 1985; Bridges and others, 1991). Since 1995, County Water and Sewer Department, written commun.,
none of the samples from well G-894 have had a chloride March 7, 2011; Craig Grossenbacher, Miami-Dade County concentration greater than 50 mg/L. The current chemistry Permitting, Environmental, and Regulatory Affairs, written of samples from well G-894, appears to be dominated by commun., July 7, 2010). These influxes included (1) a salinity recharge from precipitation rather than encroaching saltwater of 1.4 PSU measured in May 1992, (2) a salinity of 0.5 PSU because the 2H and 18O of samples from this well are about measured in March 1993, and (3) a salinity of 0.6 PSU the same as the estimated weighted mean isotopic composition measured in January 2005. Although much lower than those of annual precipitation in the catchment (see the Oxygen measured in some of the other canals, these salinities are and Hydrogen Stable Isotopes section of this report). The equivalent to chloride concentrations of about 260 mg/L most likely source of saltwater contributing to shallow saline to 760 mg/L.
influxes at well G-3601, therefore, is the Biscayne Canal The TSEMIL dataset from well G-3608 indicated a rather than saltwater encroaching from the direction of well shallow increase in bulk conductivity that may have resulted G-894. This likely source could be further evaluated by from leakage of saltwater or brackish water from the adjacent monitoring salinity in the canal adjacent to the well. Snapper Creek Canal (fig. 35A). Well G-3608 is on the west bank of Snapper Creek Canal, 3.8 km upstream of its mouth and 1.7 km upstream of salinity control structure S-22. Well Snapper Creek Canal G-3608 is open to the Biscayne aquifer in the depth interval Saltwater in the Snapper Creek Canal has leaked around 29.0 to 30.5 m. The TSEMIL dataset indicated an increase salinity control structure S-22 through the highly perme- in bulk conductivity in the depth interval 16 to 26 m of the able Biscayne aquifer and has flowed inland (Sherwood log collected April 30, 2003. The bulk conductivity gradually diminished in subsequent logs until it was no longer evident and Leach, 1962). USGS water-quality monitoring during in the TSEMIL dataset. Below a depth of 26 m, the bulk 1966 to 1992 at station Snapper Creek Canal at S-22 conductivity of logs collected from G-3608 increased between Near South Miami, Fl (USGS ID 02290700), about 60 m April 2003 and April 2006 (fig. 35A). During this period, upstream of S-22, detected brackish water in September the chloride concentrations in samples increased from 72 to 1974, December 1975, January 1976, and February, March, 230 mg/L (fig. 35B). Between 2006 and 2011 the chloride and June 1977. Chloride concentrations ranged from 254 to concentrations in samples and the bulk conductivity of logs 638 mg/L, and specific conductance ranged from 1,000 to from this well decreased to levels near those occurring prior 2,500 µS/cm during the period (U.S. Geological Survey, to the influx of conductive water. This pattern could be caused 2011f). Monthly salinity monitoring during 1988 to 2010 at by the leakage of saltwater or brackish water from the Snapper station SP04, 0.5 km upstream of water control structure S-22 Creek Canal, some of which gradually sank to the base of the (figs. 8 and 34), detected only a few influxes of saltwater in aquifer where it gradually dissipated.
50 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3608 electromagnetic induction logs 5 1/9/1996 5/24/1996 4/23/1997 4/1998 Depth, in meters below land surface 10 4/9/1999 4/13/2000 4/6/2001 5/20/2002 15 4/30/2003 2003 4/23/2004 4/26/2005 4/24/2006 20 6/13/2007 5/06/2008 5/6/2009 25 2004 2005 to 2009 Screened 30 29.0 to 30.5 meters 0 10 20 30 40 50 1996 to 2003 Bulk conductivity, in millisiemens per meter excluding 2002 B
300 18 EXPLANATION 17 Chloride concentration Bulk conductivity 250 16 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 15 200 14 13 150 12 11 100 10 9
50 8
0 7 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 35. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples collected from well G-3608 and bulk conductivity measured at a depth of 28.9 meters, Biscayne aquifer, Miami-Dade County, Florida.
Sources of Saltwater in the Biscayne Aquifer 51 The following information supports the interpretation Water levels at well G-3608 are generally 0.09 to that the conductive water detected in well G-3608 and 0.14 m higher on average than at well G-896 (fig. 37). Even G-896 emanated from the Snapper Creek Canal. if density differences resulting from changes in salinity are
- The oxygen and hydrogen stable isotope compositions considered, this head differential indicates that groundwater in samples from well G-3608 consistently plotted flow would generally be towards the east from well G-3608 closely to those of samples from the C-2 (Snapper to well G-896, rather than in the other direction. If saltwater Creek) Canal (fig. 29B), but the stable isotope com- leaked from the Snapper Creek Canal at well G-3608, the positions of samples of well G-3609, located 1.8 km prevailing groundwater-flow direction potentially could south-southeast of well G-3608, and well G-3607, move saltwater toward well G-896. This movement would located 1.7 km north of well G-3608, consistently account for (1) the occasional influxes of saltwater observed plotted closer to the intersection of the LSWML with at well G-896; (2) the similarity in interpreted piston-flow the GMWL (fig. 29B). Well G-3609 is on the salt- ages of samples from wells G-896 and G-3608; (3) the water side of the saltwater front and is open to the elevated concentrations of SF6 in samples from wells G-896 encroaching saltwater front. and G-3608, relative to those of samples from G-3609; and (4) the oxygen and hydrogen stable isotope compositions
- The interpreted piston-flow ages of water samples of the samples from well G-896, which plot closer to those from wells G-896 and G-3608 are relatively young of the surface water samples from the Snapper Creek Canal compared to those of samples from wells G-3607 and than to those of the groundwater samples from wells G-3607 G-3609 (table 5). and G-3609.
- Water from the Snapper Creek Canal near well G-3608 had SF6 concentrations ranging from 9.39 pptv in Black Creek Canal December 2009 to 37.0 pptv in July 2009 (appendix 2, table 2-4). The SF6 concentrations in samples from The TSEMIL dataset collected from well G-3702 wells G-896 and G-3608 were within this range. (fig. 38A), located on the western bank of the Black Creek Conversely samples from nearby well G-3609, which Canal 3.9 km upstream from water control structure is open below the saltwater interface, contained S-21 (fig. 8), identified a shallow influx of conductive water only 0.79 to 0.93 pptv SF6, which is about an order that may have been caused by the leakage of saltwater from of magnitude less than that of samples from wells this canal. In the June 13, 2007, log of the TSEMIL dataset, G-896 and G-3608. in the depth interval 9.8 to 17 m, there was an abrupt increase in bulk conductivity. This increase may correspond to an None of the influxes of saltwater in the Snapper influx of water in the Black Creek Canal at station BL03 on Creek Canal correspond to the interpreted piston-flow age May 9, 2007, with a salinity of 14.5 PSU (fig. 39; Maria Idia determined for water sampled from well G-3608 (table 5), Macfarlane, Miami-Dade County Water and Sewer Depart-but monthly measurements may have failed to capture a ment, written commun., March 7, 2011; Craig Grossenbacher, short-term influx of saltwater in this canal upstream of S-22, Miami-Dade County Permitting, Environmental, and Regula-and the water sampled at G-3608 is likely a mixture of water tory Affairs, written commun., July 7, 2010) 1.9 km upstream of different ages, including a relatively young component.
of water control structure S-21 and 1.9 km downstream Another potential explanation for the occurrence of saltwater from well G-3702. A salinity of 14.5 PSU corresponds to a at well G-3608 is encroachment of saltwater through a chloride concentration of approximately 8,000 mg/L. The shallow preferential flow zone occurring in the aquifer. If salinity of the water in the canal on May 9, 2007, was one of the saltwater front in this area were moving westward, the the greatest measured at this site to date and was exceeded westward movement likely would be evident in samples from only by another influx of water with a salinity of 19.6 PSU on the 18.3- to 22.6-m depth interval of well G-896, 438 m October 3, 2007.
northeast of well G-3608 and 377 m east of the Snapper Creek Canal (fig. 8). The chloride concentrations in samples The EMI log collected in well G-3702 on May 6, 2008, from well G-896 increased to a maximum of 1,500 mg/L in indicated that the conductive water detected previously in June 1992; however, by April 1998, the chloride concentra- the 9.8- to 16.8-m depth interval had almost completely tion of water in well G-896 had declined to 380 mg/L, and dissipated. If any of this conductive water sank to the base of between April 1998 and May 2012, it gradually declined the aquifer, it does not appear to have had a lasting effect on to 260 mg/L (fig. 36). The influx of saltwater detected in the water chemistry and salinity at this location because of April 2003 at well G-3608 occurred approximately 11 years the following:
after the chloride concentrations in water samples from well
- Near the bottom of well G-3702 in the depth interval G-896 began declining. If the saltwater in well G-896 was 20 to 25 m, the TSEMIL dataset indicates a conductive associated with the saltwater front, it seems unlikely that the layer. There was a small increase in bulk conductiv-saltwater front could have advanced to the location of well ity in the depth interval 17 to 20 m, but below this G-3608 in 2003 when the samples from well G-896 indicate depth, the bulk conductivity of subsequent EMI logs that the saltwater front was probably retreating. decreased slightly (fig. 38A).
52 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 10,000 EXPLANATION G-3608 G-896 Chloride concentration, in milligrams per liter 1,000 100 10 1958 1960 1962 1964 1966 1968 1970 1972 1974 1976 1978 1980 1982 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 Year Figure 36. Chloride concentrations in water samples from wells G-896 and G-3608, Miami-Dade County, Florida.
1.2 1.1 1.0 Water levels, in meters above NGVD 1929 0.9 0.8 0.7 0.6 0.5 EXPLANATION Linear regression (G-896) 0.4 Linear regression (G-3608)
G-896 0.3 G-3608 0.2 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 37. Water levels in wells G-896 and G-3608, 1996-2011, Miami-Dade County, Florida.
Sources of Saltwater in the Biscayne Aquifer 53 A
0 EXPLANATION G-3702 Electromagnetic induction logs This depth interval may have become 4/11/2000 5 contaminated with conductive water when the well was drilled. The 4/5/2001 conductive water appears to have 5/17/2002 slowly dissipated through time 5/2/2003 Depth, in meters below land surface 4/26/2004 There has been little change in bulk 4/14/2005 10 conductivity measured except in this 4/17/2006 depth interval in 2007 6/13/2007 5/6/2008 5/05/2009 15 4/9/2010 4/7/2011 Other than the year 2002, bulk conductivity measured and the chloride concentration of 20 samples from this well have remained about the same during the 12 years this well has been monitored 25 Screened 23.8 to 25.3 meters 0 20 40 60 80 100 120 140 160 Bulk conductivity, in millisiemens per meter B
2,200 100 EXPLANATION 2,000 Chloride concentration Bulk conductivity 1,800 90 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 1,600 1,400 1,200 80 1,000 800 600 70 400 200 0 60 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 38. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from well G-3702 and bulk conductivity measured at a depth of 24.6 meters, Biscayne aquifer, Miami-Dade County, Florida.
54 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 25 20 Salinity, in practical salinity units 15 10 5
0 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 39. Salinity of the Black Creek Canal at station BL03, 1991-2008 and 2010, Miami-Dade County, Florida.
- Well G-3702 is open to the aquifer in depth interval Princeton Canal 23.8 to 25.3 m. Water samples from this well indi-cate that the chloride concentration has been fairly Samples from monitoring well G-3162 (USGS constant at about 940 to 1,000 mg/L (fig. 38B) since ID 253202080232601) in the right of way of the Princeton salinity sampling began in 2002. Between June 2007 Canal (fig. 8) indicate that chloride concentrations and April 2011, chloride concentrations in this well increased from 160 to 1,300 mg/L between April 1978 and increased by only 40 mg/L. December 2011 (fig. 18) (U.S. Geological Survey, 2011f).
- The oxygen and hydrogen stable isotopic compositions Well G-3162 was not sampled during the present study of water from well G-3702 and the site C1 Canal at because well construction did not accommodate the types G-3702 do not plot close to each other (fig. 29B). of geochemical samples needed, but some of the informa-tion collected during this study indicates that the saltwater
- The SF6 concentrations in water samples from well sampled in this canal may have leaked from the canal, or G-3702 are 5.82 and 9.77 pptv, which are less than the encroached farther inland beneath the canal than on either SF6 concentration of 18.2 pptv in a sample from the canal (appendix table 2-4). side of the canal. USGS monitoring of the Princeton Canal between 1975 and 1978 at station Canal 102 at SW 107 Ave 3
H/3He age-dating of the sample from well near Homestead, FL (USGS ID 253108080215200) 1.8 km G-3702 indicated an apparent (piston flow) age of west of water control structure S-21A and 2.6 km east of
< 1970 (table 5). During the drought of 1960-63 water well G-3162, indicated two influxes of saltwater in the canal:
levels in long-term monitoring well S-182A, (USGS ID (1) between April and June 1975 with a maximum chloride 253549080214101) located 4.2 km north of well G-3702, declined to 0.20 m (U.S. Geological Survey, 2011f). This concentration of 1,300 mg/L, and (2) in March 1977 with water level was the 4th lowest water level recorded in this a chloride concentration of 2,080 mg/L (U.S. Geological well. During the 1943-57 drought, Black Creek was a stream Survey, 2011f). There is a gap of 13 years between the end of that extended from the coast to a little north of the location of USGS monitoring and the beginning of the salinity informa-well G-3702. The Black Creek Canal was dredged between tion provided by the M-D PERA (Maria Idia Macfarlane, April 1960 and December 1963 (Renken and others, 2005a). Miami-Dade County Water and Sewer Department, written These events may have allowed saltwater to leak from the commun., March 7, 2011; Craig Grossenbacher, Miami-canal as it was being dredged, or it may have encroached into Dade County Permitting, Environmental, and Regulatory the Biscayne aquifer during the drought of 1960-63. Affairs, written commun., July 7, 2010). In November 1993,
Sources of Saltwater in the Biscayne Aquifer 55 20 18 16 14 Salinity, in practical salinity units 12 10 8
6 4
2 0
1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year Figure 40. Salinity of the Princeton Canal at station PR03, 1991-2008 and 2010, Miami-Dade County, Florida.
a salinity of 18.3 PSU (fig. 40) was measured by the M-D Saltwater Encroachment PERA at station PR03 (fig. 8) near the same location where the USGS collected samples. This salinity is equivalent to The piston-flow ages and the recharge temperatures a chloride concentration of approximately 10,000 mg/L. of samples with a chloride concentration greater than or Salinities of 1.1, 2.4, 4.6, 7.6, 3.9, and 1.2 were measured in equal to about 1,000 mg/L generally correspond closely to a November 1996, February 1999, January 2005, August 2005, period with frequent droughts and the air temperatures that October 2005, and November 2008, respectively (fig. 40). are typical of the end of the dry season (figs. 30 and 31A),
These influxes of saltwater in the canal could account for when water levels in the aquifer reach a minimum (fig. 31B) an increase in salinity in the Biscayne aquifer adjacent to and saltwater encroachment along the base of the aquifer the canal. or saltwater leakage from canals is most likely to be at a TEM soundings MIA136 and MIA137 (fig. 8) collected maximum. Whether this saltwater encroached from the ocean 0.20 and 0.38 km south of the Princeton Canal, respectively, or bays, or leaked from canals, cannot be evaluated by using did not detect saltwater (appendix 4). Sounding MIA137 was these two geochemical relations alone. Differentiation of the collected 0.26 km east of the location of well G-3162. The source potentially can be made by using (1) results of the 2001 saltwater front is, therefore, at least 0.26 km farther inland HEM survey, (2) TSEMIL datasets, (3) results of long-term at the location of well G-3162 adjacent to the canal, than it monitoring of chloride concentrations (figs. 18 and 47) is 0.38 km south of the canal (fig. 8). This difference in the (U.S. Geological Survey, 2011f), and (4) information about inland extent of saltwater near the canal versus farther away other geochemical relations.
from the canal could potentially be caused by leakage of Resistivity data collected from each flight line of the saltwater from the Princeton Canal or encroachment under 2001 HEM survey (Fitterman and others, 2012) were used to the canal potentially caused by low freshwater levels caused create differential resistivity and inverted resistivity profiles.
by canal drainage. Many of these profiles intersected the saltwater front and EMI logs could not be collected from well G-3162; generally indicated a wedge-shaped mass of saltwater that therefore, the same kinds of observations made at wells extended about 9 to 15 km inland from the coast in the FKS8, G-3601, G-3608, and G-3702 could not be made for Biscayne aquifer. This wedge shape is typical of encroached this location. Also, it was not possible to collect a sample seawater (Brown and Parker, 1945). The wedge-like shape of for evaluation of the 3H/3He age. More information is encroaching saltwater is most evident in the eastern part of the needed to determine the source of the saltwater detected at HEM survey area (Fitterman and others, 2012). In the parts of well G-3162. the HEM survey area adjacent to the Card Sound Road Canal
56 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater and U.S. Highway 1, however, the slope of the intruded Although the TSEMIL datasets indicated that saltwater saltwater is almost vertical in some areas (Fitterman and is also encroaching near wells G-3601, G-3602, G-3604, and others, 2012). As discussed in the section Card Sound G-3605, the water samples from these wells did not indicate Road Canal, this is an area where saltwater has been the extent of ion depletion or enrichment observed in the other interpreted to have leaked from the canal and the old railway wells (figs. 19, 21-26). The lack of enrichment or depletion borrow ditch. is typical of areas of preexisting saltwater intrusion. Wells TSEMIL datasets can be used to evaluate the depth G-3604 and G-3605 are just south of the Tamiami and Miami intervals in which changes in the electrical conductivity of Canals where historical saltwater intrusion had occurred water are occurring. If a wedge-shaped body of saltwater (Parker and others, 1955); therefore, many of the ion exchange encroaches along the base of the aquifer, the first indication sites in this portion of the aquifer may have been filled when of encroachment at a given monitoring well is generally an saltwater previously intruded this area. Historical saltwater increase in bulk conductivity and chloride concentration near intrusion also has been documented (Parker and others, 1955) in the aquifer near wells G-3601 and G-3602, which are close the base of the aquifer. As saltwater continues to encroach, to the Biscayne and Little River Canals, respectively.
bulk conductivity and chloride concentration near the base The increases in measured bulk conductivity and chloride of the aquifer would increase, and the depth to the top of the concentration in well G-3698 may have resulted from saltwater interface would decrease. Such changes are evident saltwater encroachment, or they may be the direct or indirect in the TSEMIL datasets from 12 wells: G-3604 (fig. 41A),
results of leakage of saltwater from a canal. Well G-3698 G-3605 (U.S. Geological Survey, 2011g), G-3609 (fig. 42A),
is a few meters from a small canal that leads to the Mowry G-3615 (U.S. Geological Survey, 2011g), G-3698 (fig. 43A),
Canal. The sudden increase in bulk conductivity observed in G-3699 (fig. 44A), G-3704 (U.S. Geological Survey, 2011g),
G-3705 (U.S. Geological Survey, 2011g), G-3855 (fig. 46A), the TSEMIL dataset from this well throughout a 12-m-thick G-3856 (fig. 46B), and the deeper parts of wells G-3601 portion of the aquifer (fig. 43A) and the sudden increase and (fig. 32A) and G-3602 (fig. 45A). Long-term sampling of wells subsequent decrease in the chloride concentration in samples G-3601 (fig. 32B), G-3602 (fig. 45B), G-3604 (fig. 41B), collected from this well (fig. 18) are unusual. The changes G-3605 (fig. 18), G-3609 (fig. 42B), G-3615 (fig. 47), at well G-3698 are similar in some ways to the shallow G-3698 (fig. 43B), G-3699 (fig. 44B), G-3704 (fig. 47), and and short-term influxes of conductive water detected in the G-3705 (fig. 47) indicates that the chloride concentration has TSEMIL datasets from wells G-3601 (fig. 32A), G-3608 increased in water samples from these wells. (fig. 35A), and G-3702 (fig. 38A), where canal leakage is a Long-term chloride sampling and/or TSEMIL datasets likely factor. Saltwater has been detected in the past in the indicated that saltwater was actively encroaching near the Mowry Canal at structure S-179 near well G-3698. Eighteen base of the Biscayne aquifer in 12 wells (figs. 19, 21-26). percent of samples from the Mowry Canal on the downstream Geochemical sampling indicated the recent onset of saltwater side of structure S-179 during 1972 to 1979 indicated chloride intrusion in six of the wells (G-3615, G-3698, G-3699, concentrations ranging from 740 to 7,200 mg/L (4 to 40 PSU)
G-3704, G-3705, and G-3855) and ongoing saltwater (U.S. Geological Survey, 2011f). USGS sampling of the site encroachment in four of the wells (G-3601, G-3602, was discontinued in November 1979. Monthly measure-G-3604, and G-3605). Results were inconclusive in two ments of salinity during July 1991 to December 2008 and wells (G-3856 and G-3609). ). The recent onset of saltwater January 2010 to November 2010 at the bottom of the Mowry intrusion near wells G-1264 (fig. 18), G-3615 (fig. 47), Canal at site MW04 (fig. 48), 3.3 km upstream of water G-3698 (fig. 43B), G-3699 (fig. 44B), and G-3705 (fig. 47) control structure S-20F and 3.5 km downstream of S-179, was confirmed by long-term monitoring, indicating that the indicate that about 12 percent of the measurements had a chloride concentrations in samples increased from less than salinity of 4.3 to 23 PSU. At least some of the saltwater may 1,000 mg/L to greater than 1,000 mg/L sometime during have leaked from this canal. Whether the saltwater detected or after 1994. The chloride concentration in well G-3704 at well G-3698 leaked from the canal or encroached along (fig. 47) increased from 3,400 to 6,800 mg/L during April the base of the aquifer, or both, is uncertain given existing 2006 to April 2011. It is uncertain when the saltwater front geochemical evidence. The interpreted piston-flow age of passed this well, but it may have occurred fairly recently based the sample from well G-3698 is about 1986 (table 5), which on the rate at which salinity in this well increased. corresponds to a period with frequent droughts.
TSEMIL datasets were not collected from wells F-279, G-901, and G-1264. Each of these wells is shallower than the base of the Biscayne aquifer, but the evaluation of trace and major ions in the wells indicated that saltwater had Limitations recently intruded the aquifer at the sampling depths of these three locations (figs. 19, 21-26). Long-term monitoring The accuracy of the map showing the inland extent of indicates that the chloride concentration of sampled water saltwater in the Biscayne aquifer in 2011 (figs. 8, 17) can be increased to greater than 1,000 mg/L in 1959 at well F-279 evaluated by considering the spatial coverage of monitoring (fig. 47), in 1994 at well G-901 (fig. 47), and in 2003 at well wells and TEM soundings used to create the map (fig. 8).
G-1264 (fig. 18). The TEM soundings MIA105 and MIA106 (fig. 8), for
Limitations57 A
-3 EXPLANATION G-3604 electromagnetic 2 induction logs 8/29/1995 1/17/1996 7 5/13/1996 4/21/1997 Depth, in meters below land surface 4/3/1998 12 4/12/1999 4/13/2000 4/6/2001 17 5/14/2002 4/28/2003 4/21/2004 22 4/18/2005 9/13/2006 6/15/2007 27 5/02/2008 5/11/2009 4/20/2010 32 4/25/2011 Screened 37 35.0 to 36.6 meters 0 50 100 150 200 250 300 350 400 Bulk conductivity, in millisiemens per meter B
5,500 350 330 5,000 310 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 290 4,500 270 4,000 250 230 3,500 210 190 3,000 EXPLANATION Chloride concentration 170 Bulk conductivity 2,500 150 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 41. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in samples from monitoring well G-3604 and bulk conductivity measured at a depth of 34.7 meters, Biscayne aquifer, Miami-Dade County, Florida.
58 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3609 2 electromagnetic induction logs 4 This spike did not occur prior to the log 1/17/1996 of April 2003. There is a gap around the 5/24/1996 casing to a depth of about 9 feet.
6 Something conductive may have fallen 4/23/1997 into this gap 4/1998 Depth, in meters below land surface 8 4/9/1999 4/13/2000 10 4/06/2001 This depth interval may have become 5/20/2002 contaminated with conductive water 12 when the well was drilled. The 4/30/2003 conductive water appears to have 4/23/2004 14 slowly dissipated, and bulk conductivity 4/27/2005 in this depth interval has remained 4/24/2006 relatively constant since 2002 16 6/14/2007 4/30/2008 18 5/06/2009 4/13/2010 20 2009, 2010 4/21/2011 1997 2011 22 1996 Screened 24 24.4 to 25.9 meters 0 10 20 30 40 50 60 70 80 Bulk conductivity, in millisiemens per meter B
1,600 50 1,500 1,400 45 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 1,300 1,200 40 1,100 1,000 35 900 800 30 EXPLANATION Chloride concentration 700 Bulk conductivity 600 25 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 42. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3609 and bulk conductivity measured at a depth of 22.7 meters, Biscayne aquifer, Miami-Dade County, Florida.
Limitations59 A
0 EXPLANATION G-3698 electromagnetic induction logs Variations in bulk conductivity near the land 4/11/2000 5
surface are observed in most log sets. One 4/4/2001 possible explanation is that these variations 5/16/2002 are caused by variations in water temperature 4/25/2003 Depth, in meters below land surface near the land surface 4/20/2004 10 4/19/2005 4/18/2006 6/17/2007 Prior to April 2010, below a depth of 10 feet, the 4/29/2008 adjusted logs only differed from each other by 4/29/2009 approximately 2 millisiemens per meter 15 4/7/2010 2010 4/5/2011 2011 20 25 Screened 24.4 to 25.9 meters 0 15 30 45 60 75 90 105 120 135 150 Bulk conductivity, in millisiemens per meter B
94 EXPLANATION 2,000 Chloride concentration 84 Bulk conductivity Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 74 1,500 64 1,000 54 44 500 34 0 24 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 43. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3698 and bulk conductivity measured at a depth of 24.5 meters, Biscayne aquifer, Miami-Dade County, Florida.
60 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3699 2
electromagnetic induction logs 4
4/18/2000 4/4/2001 6
5/15/2002 Depth, in meters below land surface 8 4/25/2003 4/19/2004 10 4/19/2005 These depth intervals may have become 4/18/2006 12 contaminated with conductive water 6/12/2007 when the well was drilled. The conductive 4/28/2008 14 water appears to have slowly dissipated, and bulk conductivity in this depth interval 4/28/2009 has remained relatively constant since 2005 04/06/2010 16 04/04/2011 18 20 2011 22 24 2000 26 Screened 0 50 100 150 200 250 300 350 400 450 500 25.3 to 26.8 meters Bulk conductivity, in millisiemens per meter B
12,000 500 450 10,000 400 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 350 8,000 300 6,000 250 200 4,000 150 100 2,000 EXPLANATION Chloride concentration 50 Bulk conductivity 0 0 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 44. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3699 and bulk conductivity measured at a depth of 25.3 meters, Biscayne aquifer, Miami-Dade County, Florida.
Limitations61 A
0 EXPLANATION G-3602 5 electromagnetic induction logs 1/9/1996 10 5/13/1996 4/21/1997 4/20/1998 Depth, in meters below land surface 15 4/12/1999 4/2000 20 4/11/2001 5/13/2002 25 4/29/2003 4/22/2004 4/25/2005 30 4/25/2006 6/19/2007 35 5/07/2008 5/11/2009 4/21/2010 40 4/26/2011 45 Screened 47.2 to 48.8 meters 0 50 100 150 200 250 300 350 400 450 500 Bulk conductivity, in millisiemens per meter B
4,500 140 135 130 4,000 125 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 120 115 3,500 110 105 3,000 100 95 90 2,500 EXPLANATION 85 Chloride concentration 80 Bulk conductivity 2,000 75 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 45. (A) Time-series electromagnetic induction log (TSEMIL) dataset; and (B) chloride concentrations in water samples from monitoring well G-3602 and bulk conductivity measured at a depth of 46.9 meters, Biscayne aquifer, Miami-Dade County, Florida.
62 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A
0 EXPLANATION G-3855 electromagnetic 5 induction logs 11/21/2007 2/26/2008 Depth, in meters below land surface 4/28/2008 10 15 The depth to the saltwater interface decreased by 0.6 meter between November 21, 2007, and 20 February 26, 2008, and by another 0.4 meter between February 26, 2008, and April 28, 2008 25 Screened 25.0 to 26.5 meters 0 25 50 75 100 125 150 Bulk conductivity, in millisiemens per meter B
0 EXPLANATION G-3856 electromagnetic 5 induction logs 11/21/2007 2/26/2008 Depth, in meters below land surface 4/28/2008 10 15 The depth to the saltwater interface decreased by 1 meter between 20 November 21, 2007, and February 26, 2008 25 Screened 24.4 to 25.9 meters 0 10 20 30 40 50 60 70 80 90 100 Bulk conductivity, in millisiemens per meter Figure 46. Time-series electromagnetic induction log (TSEMIL) datasets from monitoring wells (A) G-3855 and (B) G-3856 for November 2007 to April 2008, Biscayne aquifer, Miami-Dade County, Florida
Chloride concentration, in milligrams per liter 5,000 4,500 4,000 3,500 3,000 3,500 3,000 2,500 2,500 2,000 2,000 1,500 1,000 1,500 1,000 500 0 500 0
1950 1952 1954 1956 G-3615 G-901 1958 1960 Salinity, in practical salinity units 1962 1964 0 5 10 15 20 25 1966 1968 1988 1970 1972 1989 1974 1976 1978 1990 Chloride concentration, 1980 Year 1982 1991 in milligrams per liter 1984 3,500 3,000 2,500 2,000 1986 1,500 1,000 1992 500 0 1988 1950 1990 1993 1952 1992 1954 1994 1994 1956 G-3705 1996 1958 1998 1960 2000 1995 2002 1962 1964 2004 1996 1966 2006 1968 2008 1997 1970 2010 1972 2012 1998 1974 1976 Figure 48. Salinity of the Mowry Canal at station MW04, 1991-2009 and 2010, Miami-Dade Figure 47. Chloride concentrations in samples from 1999 1978 Chloride concentration, in milligrams per liter Year 1980 8,000 4,500 7,000 6,000 5,000 4,000 3,500 3,000 Year 1982 4,000 3,000 2,500 2,000 1,500 2000 2,000 1,000 0 1,000 500 0
1984 1986 1950 2001 1952 1988 1990 1954 2002 1992 1956 F-279 G-3704 1994 1958 2003 1996 1960 1998 1962 2004 2000 1964 2002 1966 2005 2004 1968 2006 1970 monitoring wells, Miami-Dade County, Florida.
2008 1972 2006 1974 2010 2012 1976 2007 1978 1980 2008 Year 1982 1984 2009 1986 1988 2010 1990 County, Florida.
1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 Limitations63
64 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater example, are only 120 m apart; therefore, the inland extent Movement of the saltwater front is an ongoing of saltwater was narrowly constrained at this location. TEM phenomenon. The data collected for this study spanned sounding MIA106 indicated freshwater in the Biscayne 4 years, and during that time, many of the wells were actively aquifer, whereas MIA105 indicated saltwater in the aquifer monitored; as a result, the most recent information was (appendix 4). In general, however, the map was not this used to produce the maps of the inland extent of saltwater narrowly constrained. Near monitoring wells G-3229 and in 2008 and 2011. TEM soundings were completed during a G-3888 (fig. 8), no other actively monitored wells are on the 2-year period, however, and provided spatial coverage where western side of the saltwater front to constrain the determina- there were no existing data; therefore, in some locations, the tion of its inland extent. The saltwater front (1,000 mg/L extent of the saltwater front may have already changed by the time the 2011 map (fig. 8) was created. In addition, the HEM isochlor) had passed the location of well G-3229 between survey that was calibrated and published in 2012 (Fitterman October 13, 2009, and December 15, 2009 (fig. 18). By and others) had been collected in 2001. If a new HEM survey February 2011, the chloride concentration in samples from had been collected during this study, it potentially could G-3229 had increased to 1,500 mg/L (fig. 18). Generally, the have been calibrated using the TEM soundings collected precision and accuracy of the map showing the inland extent in 2009, which would have provided a direct comparison of of saltwater in the Biscayne aquifer ranged from about +/-50 m the 2001 survey with a more recent survey.
to +/- 1 km, and the line showing the inland extent of saltwater Additional samples for 3H/3He age dating could increase in the Biscayne aquifer is referred to as approximate the understanding of the sources of saltwater and the move-whenever referenced in a map. Some active monitoring wells, ment of saltwater and freshwater in the aquifer. SF6 data could such as well G-1351 (fig. 8 and appendix 1) were too shallow potentially have provided spatially distributed age dating to fully evaluate the extent of saltwater within the Biscayne information, but excess SF6 in the aquifer prevented the use of aquifer. A few active monitoring wells, such as wells F-279 this method. Analyses of the ages of samples were based on and G-3313C (fig. 8 and appendix 1) have long open the assumption of piston flow because there was insufficient intervals that may be susceptible to ambient borehole flow, information to evaluate the potential mixing of younger and which may reduce the quality of salinity measurements in the older water at each location. The piston-flow assumption may aquifer at these locations. not be valid because most of the samples were collected from Most of the active monitoring wells and the TEM near the freshwater/saltwater interface where mixing likely measurements were near the leading edge of the saltwater occurred. This mixing may have affected the ages determined front. The thickness of the saltwater front throughout the for some samples; however, if old tritium-free water were aquifer cannot be fully evaluated by using active monitoring mixed with young water, the age determined could still be accurate because tritium/helium age dating is based on an or TEM measurements. Additional monitoring, including TEM isotopic ratio (Plummer and others, 2003).
soundings and TSEMIL datasets, could allow mapping of the saltwater interface in three dimensions if collected between the leading edge of the saltwater front and the ocean. The HEM survey data collected in 2001 (figs. 1 and 16) provided Summary and Conclusions detailed three-dimensional information (Fitterman and others, 2012) concerning the distribution of saltwater, but the In Miami-Dade County, the principal source of drinking survey was limited to a small part of the county. water is the Biscayne aquifer. Prior to development, the esti-Many of the monitoring wells do not extend beyond mated level of freshwater (3 to 4.3 m) in the Everglades near the base of the Biscayne aquifer, so the depth or occurrence Miami was likely sufficient to prevent saltwater encroachment of saltwater intrusion may be uncertain. Some of the TEM in the Biscayne aquifer in this area. The head differential soundings detected saltwater in the surficial aquifer below the between the Everglades and the coast was evidenced by base of the Biscayne aquifer (Fitterman and Prinos, 2011), and numerous freshwater springs that flowed near the coast line some indicated freshwater throughout the surficial aquifer. and boiled up in Biscayne Bay. Beginning in 1845, drainage The eight new monitoring wells extend below the base of canals effectively drained the Everglades and resulted in an estimated 2.9-m permanent reduction in Biscayne aquifer the Biscayne aquifer to monitor saltwater within part of the water levels in east-central Miami-Dade County, which surficial aquifer system, but the spatial coverage of wells and allowed saltwater to encroach landward along the base of the soundings that can evaluate salinity below the base of the Biscayne aquifer. Landward encroachment was exacerbated Biscayne aquifer is limited. during drought periods when water levels in the aquifer fell to Additional monitoring in and near canals is needed to or below sea level. Saltwater also flowed inland up the canals better understand the potential effects of saltwater leakage and into the Biscayne aquifer. Water control structures on most from canals. Continuous salinity monitoring in canals, and in of the major drainage canals in Miami-Dade County reduced, wells adjacent to the canals, could help quantify the amount but did not completely eliminate, the ability of saltwater to of saltwater leaking from these canals upstream of the salinity flow inland through these canals during drought periods.
control structures. Additional TEM soundings, resistivity The various pathways of seawater into the highly permeable surveys, or monitoring wells could be used to better delineate Biscayne aquifer have combined to intrude approximately the inland extent of saltwater near canals. 1,200 km2 of this aquifer with saltwater.
Summary and Conclusions 65 To map the inland extent of saltwater in the Biscayne water with chloride concentrations less than about 1,000 mg/L aquifer, the following data were compiled and analyzed: (1) all indicate recharge temperatures corresponding to air tempera-available salinity information, (2) TSEMIL datasets from tures in mid to late May when water levels in the aquifer begin 35 wells that were processed using a newly developed method, to increase, and the piston-flow age determinations correspond (3) TEM soundings collected at 79 locations in 2008 and 2009 to wet years. The piston-flow ages of freshwater samples were and used to evaluate the depth to saltwater (if present) and the generally younger than ages determined for saltwater.
depth to the base of the Biscayne aquifer, (4) a HEM survey The silica concentrations in samples from well G-3701 collected in 2001 that was processed and interpreted during indicate that this well is screened in the Pinecrest Sand this study, (5) cores and geophysical logs collected from Member of the Tamiami Formation below the base of the 8 sites for stratigraphic analysis, (6) analyses of samples from Biscayne aquifer. Samples from the wells G-3600 and 8 new single or multi-depth monitoring wells installed in these G-3601, which are screened in a part of the Biscayne aquifer core holes, and (7) analyses of 69 geochemical samples. These that includes the Tamiami Formation, also indicated silica data were evaluated, and GIS software was used to map the concentrations that were elevated relative to samples from inland extent of saltwater in the Biscayne aquifer in 2008 and most other wells.
in 2011. The strontium (87Sr/86Sr) isotope ratio in samples was The saltwater front was mapped farther inland than it used to evaluate the origin of saltwater in the Biscayne aquifer, was in 1995 in eight approximated areas totaling 24.1 km2, but the method did not prove useful because the standard error most notably near the Florida City Canal where the front had was too large relative to the range of the 87Sr/86Sr isotope ratios advanced by as much as 1.9 km between 1995 and 2011. The in the study area. Most of the 87Sr/86Sr isotope ratios deter-saltwater interface was mapped closer to the coast than it mined from samples corresponded with the Pleistocene age was in 1995 in four approximated areas totaling 6.2 km2. The of most sediments in the Biscayne aquifer. Two of the lowest saltwater interface was mapped closer to the coast near the ratios were observed for samples from wells G-3701 and Snapper Creek Canal than it had been in 1995. Some revisions G-3601. These wells likely are open to materials that are of to the saltwater interface were the result of the improved Pliocene age.
spatial coverage provided by additional wells, TEM sound- Oxygen and hydrogen isotopes indicated that water from well G-3608 was similar in isotopic composition to ings, and the HEM survey. One area with extensive revisions water from the adjacent Snapper Creek Canal. The relatively resulting primarily from improved spatial coverage was near shallow increase in bulk conductivity evident in the TSEMIL the Card Sound Road Canal and U.S. Highway 1.
dataset from G-3608, the interpreted piston-flow age of water The sources and changes in the distribution of from this well, and the local hydraulic gradient indicated that saltwater in the Biscayne aquifer were evaluated by using the saltwater at this location likely emanated from seawater (1) geochemical sampling, (2) salinity measurements collected that had flowed up the Snapper Creek Canal and leaked into in canals, and (3) TSEMIL datasets. A total of 69 geochemical the aquifer.
water samples were collected from 44 sites. Analyses Geochemical analyses had indicated preexisting saltwater included (1) major ion chemistry and trace ion chemistry, intrusion at wells G-3600, G-3601, G-3602, G-3604, and (2) strontium isotope ratios, (3) oxygen and hydrogen isotope G-3605. The highest tritium concentrations (3.2 to 53.3 TU) ratios, (4) tritium concentration, (5) tritium/helium-3 (3H/3He) measured during the study were measured in water from age dating, (6) sulfur hexafluoride (SF6) age dating, and wells FKS4, FKS7, G-1264, G-3698, G-3699, G-3855, and (7) dissolved gas composition. G-3856. These seven wells are within 10 km of the Turkey The results of geochemical analyses indicate that Point Nuclear Power Plant, and hypersaline water with high saltwater intrusion has recently arrived at wells G-1264, tritium concentrations from the cooling canals may be contrib-G-3615, G-3698, G-3699, G-3704, G-3705, and G-3855. uting to saltwater encroachment near the wells. Geochemical Long-term records of chloride concentration confirm that the analyses and long-term monitoring data from wells G-1264, saltwater interface (1,000 mg/L) first became evident at most G-3698, G-3699, G-3855, and G-3856 confirmed the recent of these locations during or after 1994. Geochemical analyses arrival of saltwater intrusion.
at wells FKS4, FKS8, G-939, G-3600, G-3601, G-3602, 3 H/3He age dating indicated that the water sampled G-3604, and G-3605 generally indicate preexisting saltwater from wells G-3601 and G-3701 contained too little tritium intrusion as reported by previous researchers. to be evaluated using this method. The sample from well Droughts and intruded saltwater are closely connected. G-3600 showed the characteristics of gas fractionation The piston-flow ages determined from 3H/3He age samples of and could not be dated using 3H/3He age dating. Water saltwater with a chloride concentration of about 1,000 mg/L or samples from wells G-3600, G-3601, G-3602, G-3604, and greater generally correspond to a period of frequent droughts. G-3701 also indicated silica concentrations that were greater Recharge temperatures of water samples determined by using than the theoretical mixing of freshwater and saltwater in dissolved-gas analyses are consistent with air temperatures the area would produce. These elevated silica concentrations that occur in April or early May, when water levels are could be caused by relatively longer residence times within a typically at their lowest. Conversely, most of the samples of quartz-sand-rich formation.
66 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater SF6 age dating could not be used effectively in the study Bearden, H.W., 1974, Groundwater resources of the Holly-area principally because there was excess SF6 in most samples wood area, Florida: State of Florida, Department of Natural that may have been caused by leakage of SF6 from electrical Resources, Division of Interior Resources, Bureau of Geol-switching facilities. Moreover, SF6-interpreted piston-flow ogy, Report of Investigations no. 77, 35 p.
ages are generally younger than 3H/3He ages. The lowest SF6 concentrations determined were for water sampled from wells Begemann, Friedrich, and Friedman, Irving, 1959, Tritium and G-3601 and G-3701. These samples also contained no tritium. deuterium content of atmospheric hydrogen: Zeitschrift für Evaluations of long-term chloride monitoring and the Naturforschung, v. 14a, p. 1024.
geochemistry of water samples indicated that the saltwater Benson, M.A., and Gardner, R.A., 1974, The 1971 drought sampled in the Biscayne aquifer is likely not relict seawater in South Florida and its effect on the hydrologic system:
of Pleistocene or Pliocene ages. Some saltwater likely leaked U.S. Geological Survey Water-Resources Investigations from canals prior to the installation of water control structures. Report 74-12, p. 35-37.
Near the Miami Canal northwest of the water control structure S-26, this saltwater is gradually mixing with the groundwater, Bridges, W.B., Franklin, M.A., and Fleeson, T.A., 1991, Flor-and salinity is gradually decreasing. Modern leakage of ida floods and droughts in Paulson, R.W., and others, eds.,
saltwater likely is occurring along the Card Sound Road Canal National Water Summary 1988-89Hydrologic events and and upstream of salinity control structures in the Biscayne, floods and droughts: U.S. Geological Survey Water-Supply Black Creek, and Snapper Creek Canals. Saltwater also may Paper 2375, p. 231-238.
have leaked from the Princeton Canal and the canal adjacent to well G-3698, although this leakage could not be confirmed Brown, J.S., 1925, A study of coastal ground water, with or refuted with available information. special reference to Connecticut: U.S. Geological Survey Additional information, such as TEM soundings or Water-Supply Paper 537, p. 16-17.
resistivity surveys collected from the canals and monitoring wells Brown, R.H., and Parker, G.G., 1945, Salt water encroachment adjacent to these canals, could be used to evaluate the effect that in limestone at Silver Bluff, Miami, Florida: Economic saltwater leakage around or through existing structures has on Geology, v. 60, no. 4, p. 235-262.
the inland extent of saltwater in the Biscayne aquifer. Influxes of saltwater in canals may be undetected because the interval Busenberg, Eurybiades, and Plummer, L.N., 2000, Dat-between samples is too long. Continuous salinity monitoring in ing young groundwater with sulfur hexafluoride: Natural canals could be useful in the detection of any future influxes of and anthropogenic sources of sulfur hexafluoride: Water saltwater upstream of existing water control structures. Resources Research, v. 36, p. 3011-3030.
Busenberg, Eurybiades, Plummer, L.N., Doughten, M.W.,
Widman, P.K., and Bartholomay, R.C., 2000, Chemical Selected References and isotopic composition and gas concentrations of ground water and surface water from selected sites at and near the Aeschbach-Hertig, W., Peeters, F., Beyerle, U., and Kipfer, R., Idaho National Engineering and Environmental Labora-1999, Interpretation of dissolved atmospheric noble tory, Idaho, 1994-97: U.S. Geological Survey Open-File gases in natural waters: Water Resources Research, v. 35, Report 00-81, 51 p.
- p. 2779-2792.
Busenberg, Eurybiades, Weeks, E.P., Plummer, L.N., and Bar-Aeschbach-Hertig, W., Peeters, F., Beyerle, U., and Kipfer, R., tholemay, R.C., 1993, Age dating ground water by use of 2000, Paleotemperature reconstruction from noble gases chlorofluorocarbons (CC13F and CC12F2), and distribution in ground water taking into account equilibration with of chlorofluorocarbons in the unsaturated zone, Snake River entrapped air: Nature, v. 405, p. 1040-1044. Plain aquifer, Idaho National Engineering laboratory, Idaho:
U.S. Geological Survey Water-Resources Investigations Anderson, P.F., Mercer, J.W., and White, H.O., 1988, Numeri- Report 93-4054, 47 p.
cal modeling of salt-water intrusion at Hallandale, Florida:
Ground Water, v. 26, no. 5, p. 619-633. Causaras, C.R., 1987, Geology of the surficial aquifer system, Dade County, Florida: U.S. Geological Survey Water-ASTM International, 2007, Standard guide for conducting Resources Investigations Report 86-4126, 240 p., 2 sheets.
borehole geophysical loggingelectromagnetic induction:
ASTM International D 6726-01 (reapproved 2007), 8 p. Clesceri, L.S., Greenburg, A.E., and Eaton, A.D., eds., 1998, Standard methods for the examination of water and waste-Barlow, P.M., 2003, Ground water in freshwater-saltwater water (20th ed.): Washington, D.C., American Public Health environments of the Atlantic Coast: U.S. Geological Survey Association, American Water Works Association, and Water Circular 1262, 113 p. Environment Federation, p. 3-37 to 3-43.
Selected References67 Craig, Harmon, 1961, Standard for reporting concentrations of Cunningham, K.J., Wacker, M.A., Robinson, Edward, Dixon, deuterium and oxygen-18 in natural waters: Science, v. 133, J.F., and Wingard, G.L., 2006b, A cyclostratigraphic
- p. 1833-1834. and borehole geophysical approach to development of a three-dimensional conceptual hydrogeologic model of the Cross, W.P., and Love, S.K., 1942, Groundwater in southeast- karstic Biscayne aquifer, southeastern Florida: U.S. Geo-ern Florida: Journal of the American Water Works Associa- logical Survey Scientific Investigations Report 2005-5235, tion, v. 34, no. 4, p. 490-504.
75 p., 4 sheets.
Cunningham, K.J., Bukry, D., Sato, T., Barron, J.A., Guertin, Davis, S.N., Whittemore, D.O., and Fabryka-Martin, L.A., and Reese, R.S., 2001, Sequence stratigraphy of a June, 1998, Uses of chloride/bromide ratios in studies of south Florida carbonate ramp and bounding siliciclastics potable water: Ground Water, v. 36, no. 2, p. 338-350.
(late Miocene-Pliocene), in Missimer, T.M., and Scott, T.M., eds., Geology and hydrology of Lee County: Florida Federal Register Notice, 1979, October 11, 1979, v. 44, no. 198.
Geological Survey Special Publication 49, p. 35-66.
Fish, J.E., 1988, Hydrogeology, aquifer characteristics, and Cunningham, K.J., Carlson, J.L., Wingard, G.L., Robinson, groundwater flow of the surficial aquifer system, Broward Edward, and Wacker, M.A., 2004, Characterization of aqui- County, Florida: U.S. Geological Survey Water-Resources fer heterogeneity using cyclostratigraphy and geophysical Investigations Report 87-4034, 80 p.
methods in the upper part of the karstic Biscayne aquifer, southeastern Florida: U.S. Geological Survey Water- Fish, J.E., and Stewart Mark, 1991, Hydrogeology of the surfi-Resources Investigations Report 03-4208, 46 p. cial aquifer system, Dade County, Florida: U.S. Geological Survey Water-Resources Investigations Report 90-4108, Cunningham, K.J., Locker, S.D., Hine, A.C., Bukry, D., 50 p., 11 sheets.
Barron, J.A., and Guertin, L.A., 2003, Interplay of late Cenozoic siliciclastic supply and carbonate response on Fishman, M.J., ed., 1993, Methods of analysis by the U.S.
the southeast Florida Platform: Journal of Sedimentary Geological Survey National Water Quality Laboratory Research, v. 73, no. 1, p. 31-46. Determination of inorganic and organic constituents in water and fluvial sediments: U.S. Geological Survey Open-Cunningham, K.J., McNeill, D.F., Guertin, L.A., Ciesielski, File Report 93-125, 217 p.
P.F., Scott, T.M., and de Verteuil, L., 1998, New Tertiary stratigraphy for the Florida Keys and southern peninsula Fishman, M.J., and Friedman, L.C., 1989, Methods for of Florida: Geological Society of America Bulletin, v. 110, determination of inorganic substances in water and fluvial no. 2, p. 231-258. sediments: U.S. Geological Survey Techniques of Water-Resources Investigations, book 5, chap. A1, 545 p.
Cunningham, K.J., Renken, R.A., Wacker, M.A., Zygnerski, M.R., Robinson, E., Shapiro, A.M., and Wingard, G.L., Fitterman, D.V., 1989, Detectability levels for central induc-2006a, Application of carbonate cyclostratigraphy and bore- tion transient soundings: Geophysics, v. 54, p. 127-129.
hole geophysics to delineate porosity and preferential flow in the karst limestone of the Biscayne aquifer, SE Florida, Fitterman, D.V., and Deszcz-Pan, Maria, 1998, Helicopter EM in Harmon, R.S., and Wicks, C., eds., Perspectives on karst mapping of saltwater intrusion in Everglades National Park:
geomorphology, hydrology, and geochemistryA tribute Florida Exploration Geophysics, v. 29, p. 240-243.
volume to Derek C. Ford and William B. White: Geological Fitterman, D.V., and Deszcz-Pan, Maria, 2002, Helicopter Society of America Special Paper 404, p. 191-208.
electromagnetic data from Everglades National Park and Cunningham K.J., Sukop, M.C., Huang, H., Alvarez, P.F., Cur- surrounding areas, FloridaCollected 9-14 December ran, H.A., Renken, R.A., and Dixon, J.F, 2009a, Prominence 1994: U.S. Geological Survey Open-File Report 2002-101, of ichnologically influenced macroporosity in the karst Bis- 1 CD-ROM.
cayne aquiferStratiform super K zones: GSA Bulletin,
- v. 121, no. 1/2, p. 164-180. Fitterman, D.V., Deszcz-Pan, Maria, and Prinos, S.T., 2012, Helicopter electromagnetic survey of the Model Land Area, Cunningham, K.J., and Wacker, C., 2009, Seismic-sag struc- southeastern Miami-Dade County, Florida: U.S. Geological tural systems in Tertiary carbonate rocks beneath south- Survey Open-File Report 2012-1176, 75 p., 1 app.
eastern Florida, USAEvidence for hypogenic speleogen-esis? in Klimchouk, A.B., and Ford, D.C., eds., Hypogene Fitterman, D.V., Deszcz-Pan, Maria, and Stoddard, C.E., 1999, speleogenesis and karst hydrogeology of artesian basins: Results of time-domain electromagnetic soundings in Ever-Simferopol, Ukraine, Ukrainian Institute of Speleology and glades National Park, Florida (on CD-ROM): U.S. Geologi-Karstology, Special Paper no. 1, p. 151-158. cal Survey Open-File Report 99-426, 152 p.
68 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Fitterman, D., and Labson, V.F., 2005, Electromagnetic Garbarino, J.R., Kanagy, L.K., and Cree, M.E., 2006, Determi-induction methods for environmental problems, in Butler, nation of elements in natural-water, biota, sediment, and soil D.K., ed., Near-surface geophysics, part 1Concepts and samples using collision/reaction cell inductively coupled fundamentals: Tulsa, Society of Exploration Geophysicists, plasma-mass spectrometry: U.S. Geological Survey Tech-
- p. 295-349. niques and Methods, book 5, sec. B, chap. 1, 88 p.
Fitterman, D.V., and Prinos, S.T., 2011, Results of time- Geonics Limited, 2006, Protem 47D operating manual for domain electromagnetic soundings in Miami-Dade and 20/30 gate model: Geonics Limited, 80 p.
southern Broward Counties, Florida: U.S. Geological Survey Open-File Report 2011-1299, 289 p. Guertin, L.A., 1998, A late Cenozoic mixed carbonate/silici-clastic system, south FloridaLithostratigraphy, chro-Fitterman, D.V., and Stewart, M.T., 1986, Transient electro- nostratigraphy, and sea-level record: Miami, University of magnetic sounding for groundwater: Geophysics, v. 51, Miami, Ph.D. dissertation, 335 p.
- p. 995-1005.
Ghyben, W.B., 1889, Nota in verband met de voorgenomen Fletcher, D.U., 1911, Everglades of FloridaActs, reports and putboring nabij Amsterdam; K. Inst Ing. Tijdschr, 1888-89, other papers State and National, relating to the Everglades p. 21.
of the State of Florida and their reclamation: Washington, Government Printing Office, 193 p. Gibson, J.J., Edwards, T.W.D., Bursey, G.G., and Prowse, T.D., 1993, Estimating evaporation using stable isotopes:
Florea, L.J., McGee, D.K., and Wynn, J.G., 2010, Stable Quantitative results and sensitivity analysis for two catch-isotopic and geochemical variability within shallow ments in northern Canada: Nordic Hydrology, no. 24, groundwater beneath a hardwood hammock and surface p. 79-94.
water in an adjoining slough (Everglades National Park, FL): Proceedings of the 14th Symposium on the Geology of Godfrey, M.C., 2006, River of interestsWater management the Bahamas and other Carbonate Regions, 15 p., accessed in south Florida and the Everglades, 1948-2000: U.S. Army October 31, 2012, at http://digitalcommons.wku.edu/geog_ Corps of Engineers, 460 p.
fac_pub/14.
Goldman, M., Gilad, D., Ronen, A., and Melloul, A., 1991, Florida Department of Environmental Protection, 2001, Mapping seawater intrusion into the coastal aquifer of Southeast district assessment and monitoring program, Israel by the time domain electromagnetic method: Geoex-ecosummary, Miami River, Miami-Dade County, accessed ploration, v. 28, p. 153-174.
January 31, 2011, at http://www.dep.state.fl.us/southeast/
Hagemeyer, Bart, 2012, ENSOs relation with Floridas ecosum/ecosums/Miami_River.pdf.
climate and predictabilityFlorida dry season forecast and Florida Department of Health, 2005, Chemicals in private El Nino-Southern Oscillation (EÑSO): National Aeronau-drinking water wellsFact sheetSodium: Florida Depart- tical and Atmospheric Administration, National Weather ment of Health, 2 p. Service Forecast Office, Melbourne Florida, accessed January 23, 2012, at http://www.srh.noaa.gov/mlb/?n=enso_
Florida Division of Emergency Management, 2009, Miami- florida_climate_forecast.
Dade County 2 ft contour lines: Tallahassee, FL, Florida Division of Emergency Management, Shapefile, accessed Harvey, J.W., Krupa, S.L., Gefvert, Cynthia, Mooney, R.H.,
February 10, 2011, at http://www.floridadisaster.org/gis/ Choi, Jungyill, King, S.A., and Giddings, J.B., 2002, Inter-index.asp. actions between surface water and ground water and the effects of mercury transport in the north-central Everglades:
Fuller, M.L., 1904, Contributions to the hydrology of east- U.S. Geological Survey Water-Resources Investigations ern United States: U.S. Geological Survey Water-Supply Report 02-4050, 82 p.
Paper 102.
Heaton, T.H.E., 1981, Dissolved Gases: Some Applications Galli, Gianni, 1991, Mangrove-generated structures and depo- to Groundwater Research: Transactions of the Geological sitional model of the Fort Thompson Formation (Florida Society of South Africa, v. 84, p. 91-97.
Plateau): Facies, v. 25, p. 297-314.
Heaton, T.H.E., and Vogel, J.C., 1981, Excess air in ground-Garbarino, J.R., 1999, Methods of analysis by the U.S. water: Journal of Hydrology, v. 50, p. 201-216.
Geological Survey National Water Quality Laboratory Determination of dissolved arsenic, boron, lithium, sele- Herzberg, A., 1901, Die Wasserversorgung einiger Nord-nium, strontium, thallium, and vanadium using inductively seebader [The water supply on parts of the North Sea coast]:
coupled plasma-mass spectrometry: U.S. Geological Survey Munich, Jour. Gasbeleuchtung und Wasser versorgung, Open-File Report 99-093, 31 p. v. 44, p. 815-819, 842-844.
Selected References69 Hickey, T.D., Hine, H.C., Shinn, E.A., Kruse, S.E., and Poore, Katz, B.G., and Bullen, T.D., 1996, The combined use of R.Z., 2010, Pleistocene carbonate stratigraphy of south 87 Sr/86Sr and carbon and water isotopes to study the hydro-FloridaEvidence for high-frequency sea-level cyclicity: chemical interaction between groundwater and lakewater Journal of Coastal Research, v. 26, no. 4, p. 605-614. in mantled karst: Geochimica et Cosmochimica Acta, v. 60, no. 24, p. 5075-5087.
Hinkle, S.R., Shapiro, S.D., Plummer, L.N., Busenberg, Eurybiades, Widman, P.K., Casile, G.C., and Wayland, Kaufman, A.A., and Keller, G.V., 1983, Frequency and tran-J.E., 2010, Estimates of tracer-based piston-flow ages of sient sounding: Amsterdam, Elsevier, 685 p.
groundwater from selected sitesNational Water-Quality Assessment Program, 1992-2005: U.S. Geological Survey Keller, G.V., and Frischknecht, F.C., 1966, Electrical meth-Scientific Investigations Report 2010-5229, 90 p. ods in geophysical prospecting: International Series of Monographs in Electromagnetic Waves: Oxford, Pergamon Hittle, C.D., 1999, Delineation of saltwater intrusion in the sur- Press, 519 p.
ficial aquifer system in eastern Palm Beach, Martin, and St.
Lucie Counties, Florida, 1997-98: U.S. Geological Survey Kendall, C., and Coplen, T.B., 2001, Distribution of oxy-Water-Resources Investigations Report 99-4214, 1 sheet. gen-18 and deuterium in river waters across the United States: Hydrological Processes, v. 15, p. 1363-1393.
Hoffmeister, J.E., Stockman, K.W., and Multer, H.G., 1967, Miami limestone and its recent Bahamian counterpart: Geo- Klein, Howard, 1957, Salt-water encroachment in Dade logical Society of America Bulletin v. 78, p. 175-190. County, Florida: Florida Geological Survey Information Circular 9, 5 p.
Howard, K.W.F., and Lloyd, J.W., 1983, Major ion character-ization of coastal saline ground waters: Groundwater, v. 21, Klein, Howard, 1965, Probable effect of Canal 111 on salt-no. 4, p. 429-437. water encroachment, southern Dade County Florida: U.S.
Geological Survey Open-File Report 65-86, 26 p.
Howarth, R.J., and McArthur, J.M., 1997, Statistics for strontium isotope stratigraphy; a robust LOWESS fit to the Klein, Howard, and Hull, J.E., 1978, Biscayne Aquifer, marine Sr-isotope curve for 0 to 206 Ma with look-up table Southeast Florida: U.S. Geological Survey Water-Resources for derivation of numeric age: The Journal of Geology, Investigations Report 78-107, p. 22-27.
- v. 105, no. 4, p. 441-456.
Klein, Howard, and Ratzlaff, K.W., 1989, Changes in salt-Hoy, N.D., 1952, Two maps of Dade County, Florida, show- water intrusion in the Biscayne aquifer, Hialeah-Miami ing approximate position of the 1,000-ppm isochlor as of Springs area, Dade County, Florida: U.S. Geological Survey 1951 and approximate area of potential salt-water penetra- Water-Resources Investigations Report 87-4249, 1 sheet.
tion under 1945 conditions: U.S. Geological Survey Open-File Report 52-78. Klein, Howard, and Waller, B.G., 1985, Synopsis of salt-water intrusion in Dade County, Florida, through 1984:
Hoy, N.D., and others, 1951, Six cross sections and an index U.S. Geological Survey Water-Resources Investigations map of the Miami area, Florida, showing changes in the Report 85-4101, 1 sheet.
position of the salt front in the Biscayne aquifer from 1946 to 1950: U.S. Geological Survey Open-File Report 51-119. Kohout, F.A., 1964, The flow of fresh water and salt water in Hughes, J.D., Langevin, C.D., and Brakefield-Goswami, the Biscayne aquifer of the Miami area, Florida, in Cooper, Linzy, 2010, Effect of hypersaline cooling canals on aquifer H.H., Jr., Kohout, F.A., Henry, H.R., and Glover, R.E., Sea salinization: Hydrogeology Journal, v. 18, p. 25-38. water in coastal aquifers: U.S. Geological Survey Water-Supply Paper 1613-C, p. C12-C32.
Janzen, J.H., and Krupa, Steven, 2011, Water quality charac-terization of southern Miami-Dade County and nearby FPL Kohout, F.A., and Hoy, N.D., 1963, Some aspects of sampling Turkey Point Power Plant, Miami-Dade County, Florida: salty ground water in coastal aquifers: Ground Water, v. 1, South Florida Water Management District Technical Publi- no. 1, p. 28-32.
cation WS-31, 5 sections, 171 p., 6 appendixes.
Kohout, F.A., and Leach, S.D., 1964, Saltwater movement Jennings, W.S., 1909, Letter in annual report of Trustees of the caused by control-dam operation in the Snake Creek Canal, Internal Improvement Fund, State of Florida, p. 122. Miami, Florida: State of Florida, State Board of Conser-vation, Division of Geology, Florida Geological Survey, Jones, B.F., Vengosh, A., Rosenthal, E., and Yechieli, Y., 1999, Report of Investigations, no. 24, part IV, 49 p.
Geochemical Investigations, in Bear, Jacob, Cheng, A.H.D.,
Sorek, Shaul, Ouazar, Driss, and Herrera, Ismael, eds., Koszalka, E.J., 1995, Delineation of saltwater intrusion in the Seawater intrusion in coastal aquifersConcepts, methods, Biscayne aquifer, eastern Broward County Florida, 1990:
and practices: Dordrecht, Netherlands, Kluwer Academic U.S. Geological Survey Water-Resources Investigations Publishers, 625 p. Report 93-4164, 1 sheet.
70 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Lane, S.L., Flanagan, Sarah, and Wilde, F.D., 2003, Selection McNeill, J.D., 1990, Use of electromagnetic methods for of equipment for water sampling (ver. 2.0): U.S. Geologi- groundwater studies, in Ward, S.H., ed., Geotechnical and cal Survey Techniques of Water-Resources Investigations, environmental geophysics: Tulsa, Society of Exploration book 9, chap. A2, March 2003, accessed June 25, 2013, at Geophysicists, p. 191-218.
http://pubs.water.usgs.gov/twri9A2/.
McNeill, J.D., Bosnar, M., and Snelgrove, F.B., 1990, Reso-Leach, S.D., and Grantham, R.G., 1966, Salt-water study of the lution of an electromagnetic borehole conductivity logger Miami River and its tributaries, Dade County, Florida: Florida for geotechnical and ground water applications: Geonics Geological Survey Report of Investigations no. 45, 35 p. Technical Note TN-25, 28 p.
Leach, S.D., Klein, Howard, and Hampton, E.R., 1972, Meinzer, O.E., Wenzel, L.K., and others, 1940, Water levels Hydrologic effects of water control and management of and artesian pressure in observation wells in the United southeastern Florida: Florida Bureau of Geology, Report of States in 1939: U.S. Geological Survey Water-Supply Investigations no. 60, 115 p. Paper 886.
Lietz, A.C., 1999, Methodology for estimating nutrient loads Meyer, F.W., 1974, Availability of ground water for the U.S.
discharged from the east coast canals to Biscayne Bay, Navy well field near Florida City, Dade County, Florida:
Miami-Dade County, Florida: U.S. Geological Survey U.S. Geological Survey Open-File Report 74-1072, 50 p.
Water-Resources Investigations Report 99-4094, 36 p.
Miller, J.A., 1986, Hydrogeologic framework of the Floridan Lietz, A.C., Dixon, Joann, and Byrne, Michael, 2002, Average aquifer system in Florida and in parts of Georgia, South altitude of the water table (1990-99) and frequency analysis Carolina, and Alabama: U.S. Geological Survey Profes-of water levels (1974-99) in the Biscayne aquifer, Miami- sional Paper 1403-B, 91 p.
Dade County, Florida: U.S. Geological Survey Open-File Report 02-91, 7 sheets. Miller, J.A., 1990, Ground water atlas of the United States; Alabama, Segment 6; Alabama, Florida, Georgia, and South Ludin, A.I., Weppernig, Ralf, Bonisch, G., and Schlosser, Carolina: U.S. Geological Survey Hydrologic Investigations Peter, 1997, Mass spectrometric measurement of helium Atlas 730-G, 28 p.
isotopes and tritium in water samples: Lamont-Doherty Earth Observatory of Columbia University, Technical Mount Sopris Instrument Co., Inc., 2002, 2PIA-1000 Poly Report 98.6, accessed May 12, 2011, at http://www.ldeo. induction probe, 2EMA-1000 conductivity probe (2 columbia.edu/~etg/ms_ms/Ludin_et_al_MS_Paper.html. EMB-1000 and 2ECM-1000) EMP-2493 and EMP-4493:
Golden CO, Mount Sopris, 19 p.
Marella, R.L., 1993, Public-supply water use in Florida, 1990:
U.S. Geological Survey Open-File Report 93-134, 46 p. Munroe, R.M., and Gilpin, Vincent, 1930, The Commodores story, the early days on Biscayne Bay, reprinted, Historical Marella, R.L., 1999, Water withdrawals, use, discharge, and Association of Southern Florida, 1966, 384 p.
trends in Florida, 1995: U.S. Geological Survey Water-Resources Investigations Report 99-4002, 90 p. National Climatic Data Center, 2012, Normal daily mean temperature, degrees Fahrenheit: National Aeronautical Marella, R.L., 2004, Water withdrawals, use, discharge, and and Atmospheric Administration, National Climatic Data trends in Florida, 2000: U.S. Geological Survey Scientific Center, accessed January 23, 2012, at http://lwf.ncdc.noaa.
Investigations Report 2004-5151, 50 p.
gov/oa/climate/online/ccd/meantemp.html.
Marella, R.L., 2009, Water withdrawals, use, and trends in National Oceanic and Atmospheric Administration, 2012, Florida, 2005: U.S. Geological Survey Scientific Investiga-Sea levels online: National Oceanic and Atmospheric tions Report 2009-5125, p. 11.
Administration, accessed November 30, 2012, at http://
Matson, G.C., and Sanford, S., 1913, Geology and ground tidesandcurrents.noaa.gov/sltrends/sltrends.shtml.
waters of Florida: U.S. Geological Survey Water-Supply Northwest Dade County Freshwater Lake Belt Plan, 1997, Paper 319, 445 p.
Making a whole not just a hole: South Florida Water Man-McArthur, J.M., Howarth, R.J., and Shields, G.A., 2012, agement District, 30 p.
Strontium Isotope Geochronology in The Geologic Time Scale, Gradstein, F.M., Ogg, J.G., Schmitz, M.D., Ogg, Oki, D.S., and Presley T.K., 2008, Causes of borehole flow G.M., eds., Elsevier Amsterdam, 1040 p., 3 appendixes. and effects on vertical salinity profiles in coastal aqui-fers: Conference program and proceedings, Program and McNeill, J.D., 1986, Geonics EM39 borehole conductivity proceedings book, 20th Salt Water Intrusion Meeting, meter theory of operation: Geonics Limited, Technical Note June 23-27, 2008, p. 170-173, accessed June 14, 2013, at TN-20, 9 p., 1 addendum. http://conference.ifas.ufl.edu/swim/papers.pdf.
Selected References71 Oldenburg, D.W., and Li, Y., 2005, Inversion for applied Reese, R.S., and Cunningham, K.J., 2000, Hydrogeology geophysicsA tutorial, in Butler, D.K., ed., Near surface of the gray limestone aquifer in southern Florida: U.S.
geophysics, Part 1Concepts and fundamentals: Tulsa, Geological Survey Water-Resources Investigations Report Society of Exploration Geophysicists, p.89-150. 99-4213, 244 p.
Paige, J.C., 1986, Historic resource study for Everglades Reese, R.S., and Richardson, E., 2008, Synthesis of the hydro-National Park, U.S. Department of the Interior, National geologic framework of the Floridan aquifer system and Park Service: Department of Commerce, National Technical delineation of a major Avon Park permeable zone in central Information Service, PB87199097, p. 138-143. and southern Florida: U.S. Geological Survey Scientific Investigations Report 2007-5207, 60 p.
Parker, G.G., 1945, Salt water encroachment in southern Florida: Journal of the American Water Works Association, Reese, R.S., and Wacker, M.A., 2009, Hydrogeologic and
- v. 37, no. 6, p. 526-542. hydraulic characterization of the surficial aquifer system, and origin of high salinity groundwater, Palm Beach County Parker, G.G., and Cooke, C.W., 1944, Late Cenozoic geology Florida: U.S. Geological Survey Scientific Investigations of southern Florida, with a discussion of the groundwater:
Report 2009-5113, 42 p., 2 appendixes.
Florida Geological Survey, Geological Bulletin no. 27, 3 pls.
Renken, R.A., Cunningham, K.J., Shapiro, A.M., Harvey, Parker, G.G., Ferguson, G.E., Love, S.K., and others, 1955, R.W., Zygnerski, M.R., Metge, D.W., and Wacker, M.A.,
Water resources of southeastern Florida, with special refer-2009, Pathogen and chemical transport in the karst lime-ence to the geology and ground water of the Miami area:
stone of the Biscayne aquifer1. Revised conceptualiza-U.S. Geological Survey Water-Supply Paper 1255, 965 p.
tion of groundwater flow: Water Resources Research, v. 44, Parks, A.M., 1987, Miami memoirs, John SewellA new W08429, doi:10.1029/2007WR006058.
pictorial addition: Miami, Arva Parks & Co., 267 p.
Renken, R.A., Dixon, Joann, Koehmstedt, John, Ishman, Perkins, R.D., 1977, Depositional framework of Pleistocene Scott, Lietz, A.C., Marella, R.L., Telis, Pamela, Rodgers, rocks in south Florida, in Enos, Paul, and Perkins, R.D., Jeff, and Memberg, Steven, 2005a, Impact of anthropo-eds., Quaternary sedimentation in south Florida: Geological genic development on coastal ground-water hydrology in Society of America Memoir 147, p. 131-198. southeastern Florida, 1900-2000: U.S. Geological Survey Circular 1275, 77 p.
Plummer, L.N., Bhkle, J.K., and Busenberg, Eurybiades, 2003, Approaches for ground-water dating, in Lindsey, Renken, R.A., Shapiro, A.M., Cunningham, K.J., Harvey, B.D., Phillips, S.W., Donnelly, C.A., Speiran, G.K., Plum- R.W., Metge, D.W., Zygnerski, M.R., Osborn, C.L., Wacker, mer, L.N., Bhlke, J.K., Focazio, M.J., Burton, W.C., M.A., and Ryan, J.N., 2005b, Assessing the vulnerability of and Busenberg, Eurybiades, Residence times and nitrate a municipal well field to contamination in a karst aquifer:
transport in groundwater discharging to streams in the Environmental and Engineering Geoscience, v. 11, no. 4, Chesapeake Bay Watershed: U.S. Geological Survey Water- p. 341-354.
Resources Investigations Report 03-4035, p. 12-24.
Révész, Kinga, and Coplen, T.B., 2008a, Determination of the Prinos, S.T., 2005, Correlation analysis of a ground-water (2H/1H) of water: RSIL lab code 1574, chap. C1 of Révész, level monitoring network, Miami-Dade County, Florida: Kinga, and Coplen, T.B., eds., Methods of the Reston Stable U.S. Geological Survey Open-File Report 2004-1412. Isotope Laboratory: U.S. Geological Survey Techniques and (Also available at http://pubs.usgs.gov/of/2004/1412/ Methods 10-C1, 27 p.
index.html.)
Révész, Kinga, and Coplen, T.B., 2008b, Determination of Prinos, S.T., Lietz, A.C., and Irvin, R.B., 2002, Design of a real- the (180/160) of water: RSIL lab code 489, chap. C2 of time ground-water level monitoring network and portrayal of Révész, Kinga, and Coplen, T.B., eds., Methods of the hydrologic data in southern Florida: U.S. Geological Survey Reston Stable Isotope Laboratory: U.S. Geological Survey Water-Resources Investigation Report 01-4275, 108 p. Techniques and Methods, 10-C2, 28 p.
Raymer, L.L., Hunt, E.R., and Gardner, J.S., 1980, An Richter, B.C., and Kreitler, C.W., 1993, Geochemical tech-improved sonic transit time-to-porosity transform, paper P, niques for identifying sources of ground-water salinization:
in 21st Annual Logging Symposium Transactions: Society Boca Raton, FL, CRC Press, 258 p.
of Professional Well Log Analysts, 12 p.
Rupert, M.G., and Plummer, L.N., 2004, Ground-water flow Reese, R.S., 1994, Hydrogeology and the distribution and ori- direction, water quality, recharge sources, and age, Great gin of salinity in the Floridan aquifer system, southeastern Sand Dunes National Monument, south-central Colorado, Florida: U.S. Geological Survey Water-Resources Investiga- 2000-2001: U.S. Geological Survey Scientific Investiga-tions Report 94-4010, 56 p. tions Report 2004-5027, 28 p.
72 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Schlosser, Peter, Stute, Martin, Dorr, Helmut, Sonntag, Sonenshein, R.S., and Koszalka, E.J., 1996, Trends in Christian, and Munnich, K.O., 1988, Tritium/3He dating of water-table altitude (1984-1993) and saltwater intru-shallow groundwater: Earth and Planetary Science Letters, sion (1974-1993) in the Biscayne aquifer, Dade County,
- v. 89, p. 353-362. Florida: U.S. Geological Survey Open-File Report 95-705, 2 sheets.
Schlosser, Peter, Stute, Martin, Sonntag, Christian, and Mun-nich, K.O., 1989, Tritiogenic 3He in shallow groundwater: Southeastern Geological Society Ad Hoc Committee on Earth and Planetary Science Letters, v. 94, p. 245-256. Florida Hydrostratigraphic Unit Definition, 1986, Hydro-geological units of Florida: Florida Department of Natural Schmerge, D.L., 2001, Distribution and origin of salinity in Resources, Bureau of Geology, Special Publication 28, 9 p.
the surficial and intermediate aquifer systems, southwestern Florida: U.S. Geological Survey Water-Resources Investiga- South Florida Water Management District, 1985, Interim tions Report 2001-4159, 41 p. drought management report: South Florida Water Manage-ment District May 9, 1985, Update, 112 p.
Schroeder, M.C., and Klein, Howard, 1954, Geology of the western Everglades Area, southern Florida: Florida Geo- South Florida Water Management District, 2010, Water use logical Survey, Geologic Survey Circular 314, 26 p. permit no. re-issue 13-00017-W, non-assignable, South Schroeder, M.C., Klein, Howard, and Hoy, N.D., 1958, Bis- Water Management District, 31 p., 37 app., Exhibit 5A, cayne aquifer of Dade and Broward Counties, Florida: Florida accessed January 12, 2012, at http://www.miamidade.gov/
Geological Survey Report of Investigations no. 17, 56 p. wasd/wup.asp.
Shaler, N.S., 1890, The topography of Florida: Bulletin of the Stalker, J.C., McFarlane, Andrew, and Price, R.M., 2010, Museum of Comparative Zoology at Harvard College, v. 16, Geochemical investigation of the surface water and ground-no. 7, p. 139-156. water in the immediate vicinity of Florida Power and Light, Turkey Point Cooling Canals: Florida International Shalev, Eyal, Lazar, Ariel, Wollam, Stuart, Kington, University, 43 p.
Shushanna, Yechieli, Yoseph, and Gvirtzman, Haim, 2009, Biased monitoring of freshwater-salt water mixing zone in Stewart, M.A., Bhatt, T.N., Fennema, R.J., and Fitterman, coastal aquifers: Ground Water, v. 47, no. 1, p. 49-46. D.V., 2002, The road to flamingoAn evaluation of flow pattern alterations and salinity intrusion in the Lower Shapiro, A.M., Renken, R.A., Harvey, R.W., Zygnerski, Glades, Everglades National Park: U.S. Geological Survey M.R., and Metge, D.W., 2008, Pathogen and chemical Open-File Report 2002-59, 36 p.
transport in the karst limestone of the Biscayne aqui-fer2. Chemical retention from diffusion and slow Stoneman-Douglas, Marjory, 1947, The EvergladesRiver of advection: Water Resources Research, v. 44, W08430, grass: Sarasota, Florida, Pineapple Press, Inc., 50th Anni-doi:10.1029/2007WR006059. versary Edition, 1997, 455 p.
Shaw, T.J., Moore, W.S., Kloepfer, Jeremiah, and Sochaski, Swayze, L.J., 1980, Water-level contour and salt front map, M.A., 1998, The flux of barium to the coastal waters of the Hialeah-Miami Springs well field area, Dade County, southeastern USAThe importance of submarine ground- Florida, October 13, 1978: U.S. Geological Survey Open-water discharge: Geochimica et Cosmochimica Acta, v. 62, File Report 80-8, 1 sheet.
no. 18, p. 3047-3054.
Taylor, K.C., Hess, J.W., and Mazzela, Aldo, 1989, Field Sherwood, C.B., and Klein, Howard, 1963, Surface- and evaluation of slim-hole borehole induction tool: Groundwa-ground-water relation in a highly permeable environment: ter Monitoring & Remediation, v. 9, issue 1, p. 100-104.
Berkeley, International Association of Scientific Hydrology, publication no. 63, p. 454-463. The Weather Channel, 2013, Monthly and daily averages for Miami, Florida, accessed January 3, 2011, at http://
Sherwood, C.B., and Leach, S.D., 1962, Hydrologic studies www.weather.com/weather/wxclimatology/monthly/graph/
in the Snapper Creek Canal area, Dade County, Florida: USFL0316.
Florida Geological Survey, Report of Investigations no. 24, Part II, 32 p. Trimble, P.J., Marban, J.A., Molian, Medardo, and Scully, S.P.,
1990, Analysis of the 1989-1990 drought: South Florida Smith, R.S., 1909, The reclamation of the Florida Everglades, Water Management District Special Report DRE 286, 80 p.
Miami, Florida, p. 16b.
Turekian, K.K., 1976, Oceans (2d ed.): Prentice-Hall, 149 p.
Sonenshein, R.S., 1997, Delineation and extent of saltwater intrusion in the Biscayne aquifer, eastern Dade County, U.S. Census Bureau, 2010, State and county quick facts, Florida, 1995: U.S. Geological Survey Water-Resources Miami-Dade County, Florida, accessed September 9, 2011, Investigations Report 96-4285, 1 sheet. at http://quickfacts.census.gov/qfd/states/12/12086.html.
Selected References73 U.S. Census Bureau, 2013, Population estimates, counties, U.S. Geological Survey, 2011f, National Water Information accessed March 15, 2013, at http://www.census.gov/popest/ SystemWeb interfaceWater Data for the Nation: U.S.
data/historical/index.html. Geological Survey, accessed October 5, 2011, at http://nwis.
waterdata.usgs.gov/usa/nwis/.
U.S. Congress, 1850, Index to Executive Documents printed by order of the United States during the first session of the thirty- U.S. Geological Survey, 2011g, Saline intrusion monitoring, first congress 1849-50, Washington: Wm. M. Belt, 98 p. Miami-Dade County, Florida: U.S. Geological Survey, accessed October 10, 2011, at http://www.envirobase.usgs.
U.S. Environmental Protection Agency, 2000, SF6 Emis- gov/FLIMS/.
sions reduction partnership for electronic power systems, annual report, 2000: U.S. Environmental Protection Agency, U.S. Geological Survey, 2011h, Groundwater conditions 9 p., accessed May 17, 2001, at http://www.epa.gov/ in southern Florida: U.S. Geological Survey, accessed electricpower-sf6/documents/sf6_emiss_rep.pdf. October 5, 2011, at http://www.sflorida.er.usgs.gov/edl_
data/index_ndt.html.
U.S. Environmental Protection Agency, 2011a, Second-ary drinking water regulations; guidance for nuisance U.S. Geological Survey, 2011i, Reston Chlorofluorocarbon chemicals: U.S. Environmental Protection Agency LaboratoryAnalytical procedures for dissolved gasses Report 816-f-10-079, accessed January 26, 2011, at http:// N2 / Ar: U.S. Geological Survey, accessed April 26, 2011, water.epa.gov/drink/contaminants/secondarystandards.cfm. at http://water.usgs.gov/lab/dissolved-gas/lab/analytical_
procedures/.
U.S. Environmental Protection Agency, 2011b, Drinking water contaminantsNational primary drinking water standards, Van Wagoner, J.C., 1985, Reservoir facies distribution as accessed February 23, 2011, at http://water.epa.gov/drink/ controlled by sea-level change: Abstract and Poster Session, contaminants/index.cfm. Society of Economic Paleontologists and Mineralogists Mid-Year Meeting, Golden, Colorado, p. 91-92.
U.S. Geological Survey, variously dated, National field manual for the collection of water-quality data: U.S. Geo- Vengosh, Avner, and Pankratov, Irena, 1998, Chloride/bromide logical Survey Techniques of Water-Resources Investiga- and chloride/fluoride ratios of domestic sewage effluents tions, book 9, chaps. A1-A9, available online at http://pubs. and associated contaminated ground water: Ground Water, water.usgs.gov/twri9A. v. 36, no. 5, p. 815-824.
U.S. Geological Survey, 2011a, Reston Chlorofluorocar- Verdi, R.J., Tomlinson, S.A., and Marella, R.L., 2006, The bon LaboratorySF6 sampling: U.S. Geological Survey, drought of 1998-2002Impacts on Floridas Hydrology and accessed April 29, 2011, at http://water.usgs.gov/lab/sf6/ Landscape: U.S. Geological Survey Circular 1295, 34 p.
sampling/.
Wacker, M.A., 2010, Tools and data acquisition of borehole U.S. Geological Survey, 2011b, Reston Chlorofluorocarbon geophysical logging for the Florida Power and Lights Com-LaboratoryDissolved Gas N2 / Ar and 4He Sampling: pany Turkey Point Power Plant in support of a groundwater, U.S. Geological Survey, accessed June 25, 2013, at http:// surface-water, and ecological monitoring plan, Miami-water.usgs.gov/lab/dissolved-gas/sampling/. Dade County, Florida: U.S. Geological Survey Open-File Report 2010-1260, 5 p., appendixes.
U.S. Geological Survey, 2011c, Reston Chlorofluorocarbon Laboratory3H/3He sampling: U.S. Geological Survey, Wacker, M.A., and Cunningham, K.J., 2008, Borehole geo-accessed April 26, 2011, at http://water.usgs.gov/lab/3h3he/ physical logging programIncorporating new and existing sampling/. techniques in hydrologic studies: U.S. Geological Survey Fact Sheet 2008-3098, 4 p.
U.S. Geological Survey, 2011d, Reston Chlorofluorocarbon LaboratoryAnalytical procedures for SF6: U.S. Geologi- Waller, B.G., 1985, Drought of 1980-82 in southeast Florida cal Survey, accessed April 26, 2011, at http://water.usgs. with comparison to the 1961-62 and 1970-71 droughts:
gov/lab/sf6/lab/analytical_procedures/. U.S. Geological Survey Water-Resources Investigations Report 85-4152, p. 24-28.
U.S. Geological Survey, 2011e, Annual Water Data Reports:
U.S. Geological Survey, accessed June 18, 2013, at Wright, J.O., 1912, The Everglades of FloridaTheir adapt-http://wdr.water.usgs.gov/. ability for the growth of sugar cane: Tallahassee, FL, 81 p.
Appendixes 1-12 76 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Appendix 1. Site Location and Appendix 3. Salinity Profiles Construction Information Collected from the Card Sound Road Appendix 1 provides site location and construction Canal information for sites used to evaluate the inland extent Salinity profiles were collected in the Card Sound Road of saltwater or the causes of saltwater intrusion in the Canal to evaluate the extent to which saltwater can flow inland Biscayne aquifer. Monitoring results from these sites are along this canal (appendix 3). The latitude and longitude of available from the USGS Annual Water Data Reports and each site are provided in a decimal degree format that has been National Water Information SystemWeb interfaceWater adjusted to the NAD83 datum. This can be used to import this quality samples for the Nation websites (U.S. Geological file into a GIS.
Survey, 2011a, b) or from the organizations listed in this See supplemental file http://pubs.usgs.gov/sir/2014/5025/
appendix. This information is provided in a supplementary appendix/sir2014-5025_appendix_03.xlsx.
Microsoft ExcelTM file. The latitude and longitude of each site are provided in a decimal degree format that has been adjusted to the NAD83 datum. This can be used to import this file into a GIS. Appendix 4. Results of Time-Domain See supplemental file http://pubs.usgs.gov/
Electromagnetic Soundings sir/2014/5025/appendix/sir2014-5025_appendix_01.xlsx. Appendix 4 provides a summary of information concerning 79 TEM soundings that were made during 2008 and 2009. This summary is provided in a supplementary Microsoft ExcelTM file. Soundings MIA101-MIA137 were References collected between April 28, 2008, and May 8, 2008. Soundings MIA201-MIA242 were collected between February 23, 2009, U.S. Geological Survey, 2011a, Annual Water Data Reports: and March 9, 2009. The 2008 field season focused on gathering U.S. Geological Survey, accessed June 18, 2013, at information from the Broward County line south to Florida http://wdr.water.usgs.gov/. City in southern Miami-Dade County to fill gaps in the spatial coverage of existing monitoring wells and to determine if the U.S. Geological Survey, 2011b, National Water Information extent of saltwater encroachment had changed since the work SystemWeb interfaceWater Data for the Nation: U.S. of Sonenshein (1997). The 2009 field season was focused Geological Survey, accessed October 5, 2011, at primarily in southeast Miami-Dade County in the Model Land, http://nwis.waterdata.usgs.gov/usa/nwis/. but also includes a number of soundings in southern Broward County, which helped to establish the location of the saltwater front in northern Miami-Dade County. The soundings collected in the Model Land were located to help interpret the HEM Appendix 2. Results of Geochemical survey flown in 2001 to map saltwater encroachment. The locations of the TEM soundings were determined by global Sampling positioning system (GPS) measurements. Horizontal coordi-nates are in UTM Zone 17R, in meters, referenced to NAD 83.
Appendix 2 provides the results of 69 geochemical Positioning errors are 4 to 5 m. Detailed information concerning samples and 3 replicate samples from 44 sites. This these measurements is provided in Fitterman and Prinos (2011).
information is available in 7 supplementary Microsoft See supplemental file http://pubs.usgs.gov/sir/2014/5025/
ExcelTM files. appendix/sir2014-5025_appendix_04.xlsx.
See supplemental files:
Appendix_02_Table1.xlsx References Appendix_02_Table2.xlsx Appendix_02_Table3.xlsx Fitterman, D.V., and Prinos, S.T., 2011, Results of time-Appendix_02_Table4.xlsx domain electromagnetic soundings in Miami-Dade and Appendix_02_Table5.xlsx southern Broward Counties, Florida: U.S. Geological Sur-Appendix_02_Table6.xlsx vey Open-File Report 2011-1299, 289 p.
Appendix_02_Table7.xlsx Sonenshein, R.S., 1997, Delineation and extent of saltwater intrusion in the Biscayne aquifer, eastern Dade County, available at http://pubs.usgs.gov/sir/2014/5025/appendix/ Florida, 1995: U.S. Geological Survey Water-Resources sir2014-5025_appendix_02. Investigations Report 96-4285, 1 sheet.
Appendixes77 Appendix 5. Time-Series the probe near an area with the potential for electromagnetic interference. When there is a significant difference between Electromagnetic Induction Log the temperature of the induction probe and the temperature of water in the borehole, there can be a shift in the observed log (TSEMIL) Dataset Calibration and (Mount Sopris Instrument Co., Inc., 2002, p. 15), so prior to Processing calibration, the probe is allowed to equilibrate with the water in the well at a depth of about 6 m until the readings stabilize.
The following is a synopsis of induction log calibration Once readings are stable, the probe is removed from the well, procedures and TSEMIL dataset processing. and the calibration is performed as quickly as possible to reduce temperature-induced variations. Following calibration, the probe is returned to the well at a depth of about 6 m and Calibration Procedures is again allowed to equilibrate with the water in the well until readings are constant. Once readings have stabilized, the probe Prior to the collection of individual induction logs, is raised until a selected reference point on the probe aligns factory-prescribed procedures (Mount Sopris Instrument Co.,
with a reference point near the top of the well. The down-hole Inc., 2002, p. 7-11, 15) that adhere to ASTM International log is then collected. Logs are generally collected in both guidelines (ASTM International, 2007) are used to calibrate a down-hole and an up-hole direction. These two logs are the logging probe. Given the variety of equipment used compared to evaluate the quality of each log. In tight wells, through time, differences in temperature and humidity during the probe may become temporarily stuck in the well even as calibrations, and variations in instrument sensitivity and drift, additional cable is played out by the winch. This can cause a the only actual constants existing in the calibration process are temporary discontinuity between the actual depth of the probe the calibration coils themselves. Each calibration performed and the depth recorded by the winch. To ensure data quality, is an attempt to align the data with these constants. The probe therefore, the up-hole log is generally used because this allows readings in counts per second (cps) are converted to values of the maximum amount of time for the probe temperature to bulk conductivity by using the equation of a straight line that achieve equilibrium with the water in the borehole and because is determined by a two-point calibration process. Calibration the cable connected to the probe is under constant tension, is accomplished by using a factory-manufactured calibration which reduces the potential for inaccurate depth measurements.
coil. The coil is designed to provide known bulk conductivity The induction logging systems and software used for values that can be selected by using a switch on the coil. collection of the logs presented in this report have changed Available settings are 0, 91, 460, and 1,704 mS/m. The settings a number of times during the 17 years that data have been selected depend on the desired range, which can be 0 to 100, collected. Between 1995 and 1997, the equipment used was a 0 to 1,000, or 0 to 10,000 mS/m. During the calibration Mount Sopris Instrument Co., Inc. MGX portable logging unit process, a coil setting of zero is selected for the first calibration operated using Logshell' software, an MGB-1000 ultralight point. The second calibration point is obtained by selecting the winch, and an EMA-1000 induction probe. The EMA-1000 coil setting that is most appropriate for the selected range. The induction probe is based on the Geonics EM39 induction range used for this effort was 0 to 1,000 mS/m because many probe. In 1998, the MGX portable logger was upgraded by of the wells used already yielded saltwater. installing a digital MGXII console using Logshell' software.
Several different calibration settings and methods were Beginning in 2000, the Logshell' software was upgraded used during this effort. An older calibration coil used for this to MSLog' software. The Logshell' software was used study had settings of 0, 81, 345, and 1,301 mS/m. This coil again for the logs collected in 2001 because of the trunca-was used to calibrate the logs collected from 1996 to 2007. tion of some of the values recorded in the output files. The This coil is discussed in greater detail in subsequent sections EMA-1000 induction probe malfunctioned in 2002, and the of this appendix. The logs collected in 1995 were calibrated logs collected that year were obtained by using an induction by using an alternate procedure described by Mount Sopris probe borrowed from the USGS Tennessee Water Science Instrument Co., Inc., (2002, p. 7) that uses free air for the zero Center. A new induction probe was purchased and used from setting and a value for the second calibration point that consists 2003 to 2006. The truncation issues related to the software had of the frequency of pulses from the tool at the zero point been addressed by 2002, and instrumentation was operated plus 5,000. Most of the logs collected during 1996 to 2001, using MSLog' software during 2002 to 2006. In 2007, after excluding 1998, were calibrated by using a setting of 1,301 on another probe malfunction, an EM39 induction probe was the calibration coil for the second calibration point. Most of the rented from Colog Borehole Geophysical Services for the logs collected in 1998 and during 2002 to 2007 were calibrated collection of logs that year. Currently (2013), a 2PIA-1000 by using the 345-mS/m setting for the second point. All of the EM39 induction probe, a 4305-1000-120 mini winch, and a logs collected since 2008 have been calibrated by using the 5MXA-1000-120 Matrix' logging console operated using newer coil and a setting of 460 for the second point. Matrix' logging software are being used.
During calibration, metal objects also are kept as far Although there have been a number of modifications from the probe as possible. Care is taken to avoid calibrating to the probes that have been used through time, all of the
78 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater probes used were based on the EM39 design. The EM39 and measurement process rather than by actual changes in probe provides a radius of maximum sensitivity of 28 cm, a aquifer water quality because these offsets are almost perfectly radius of minimum sensitivity of 10 cm, and vertical resolu- uniform throughout the thickness of freshwater parts of the tion of 65 cm (McNeill, 1986; Mount Sopris Instrument Co., aquifer. The offsets could be caused by slight differences in Inc., 2002, p. 17). This means that the probe is insensitive calibration resulting from variations in temperature, humidity, to changes in borehole fluid in wells with a diameter of less and calibration time, because the probe must be removed than 20 cm. Most of the wells logged during this study had a from the well for calibration. Even though the offsets are diameter of 5 cm, and changes in the electrical conductivity of small (+/-7 mS/m), they obscure the ability to identify small the fluid in these boreholes should not have affected the logs. but real changes in bulk conductivity that occurred as changes The probe provides appreciable sensitivity out to a radius of in the salinity of the pore water occurred. A technique was 100 cm (McNeill and others, 1990, p. 5). Measurement resolu- developed, therefore, to remove the offsets to create TSEMIL tion and accuracy are 0.02 and 5 percent of full scale, respec- datasets that could be used to more clearly identify changes in tively (Mount Sopris Instrument Co., Inc., 2002, p. 17). Given bulk conductivity resulting from saltwater intrusion.
the full scale of 1,000 mS/m, the accuracy is about 50 mS/m. The offsets apparent in the time series of EMI logs The data collected in the study area by the USGS during the (fig. 5-1) are removed on a log-by-log basis. An important last 17 years, using various versions of the EM39 induction consideration of this procedure is that if there are no actual probe and varying calibration methods, and coils, however, changes in the electrical conductivity of water occurring indicate that much greater accuracy may be possible. Although through time in the aquifer, then the adjustments made to there were some issues with calibration slope and offset, once the time series of EMI logs should not alter the mean bulk they were addressed, the data collected where salinity is not conductivity of the set of EMI logs. In other words, with changing tended to agree to within +/- 1.0 to 1.5 mS/m even few exceptions, the corrected set of EMI logs should not be though changes have been made to the hardware and software skewed to the left or right of the mean of the uncorrected set used to collect these logs. of logs. The offsets between individual EMI logs were nearly constant throughout the freshwater-saturated interval; aligning individual logs to the left or right of the mean bulk conduc-Corrections of Calibration Slope tivity measured at one depth generally created near perfect alignment at all depths in the freshwater-saturated interval.
A two-point calibration process is used to determine The correction process consisted, therefore, of (1) determining the equation of a straight line that is used by the operating the mean bulk conductivity measured by the full time series of software to convert probe readings (cps) to bulk conductivity.
EMI logs at a selected depth within the freshwater-saturated The equation of this line includes a slope and offset. Rela-interval, (2) determining the difference between this value tively large errors in the calibration slope of logs were caused and the bulk conductivity measured at this same depth for during 1996 to 2007 by using a calibration coil that had been an individual log of the set, (3) subtracting this difference marked at the factory with incorrect values and during 1996 to from each bulk conductivity measurement of that log, and 2001 (excluding 1998) by using a second calibration point that (4) repeating this process for all logs in the set until they was greater than the full-scale reading of 1,000 mS/m. The were all aligned to the mean bulk conductivity at the selected calibration coil error was discovered in 2008 when logs were depth. This process creates near perfect alignment of the set of collected using a new calibration coil from the same factory.
EMI logs and creates the ability to identify small differences Both coils were sent back to the factory for examination.
between logs that were otherwise obscured by the offsets that This examination revealed that the coil settings labeled 81, had been present (fig. 5-2).
345, and 1,301 mS/m should have been labeled 91, 460, and The first EMI log of the TSEMIL dataset from well 1,700 mS/m, respectively, and that given the incorrect labels, G-3611 collected on January 9, 1996, shows slightly elevated the calibrations applied during 1996 to 2007 were generally bulk conductivity at depths of 6.7 and 16.7 m (fig. 5-2). This off by about 11 to 25 percent. After the necessary corrections change in bulk conductivity is a common observation in many had been applied to the slope of the affected logs, only minor of the TSEMIL datasets from new wells. It likely results from
+/-7 mS/m offsets remained between any of logs.
water of greater than normal electrical conductivity entering porous rock layers during the drilling process. Generally, the TSEMIL Dataset Processing electrically conductive water dissipates during the first few years of logging the well.
Where a time series of EMI logs was collected from a A simple method to ensure that the corrections were well penetrating freshwater parts of the Biscayne aquifer, the applied correctly is to verify that the sum of all corrections individual EMI logs of the set are nearly identical, with the applied is zero. By using the corrections that were applied to exception of small and uniform offsets in bulk conductivity align individual logs to the mean of all logs at a given depth, between the logs collected on different dates (fig. 5-1). the standard deviation of a TSEMIL dataset may also be These offsets are generally within +/-7 mS/m of the mean of determined. Simple graphical examinations of the time series the log set. The offsets are likely caused by the calibration of the logs prior to and following these corrections allow the
Appendixes79 0
EXPLANATION G-3611 electromagnetic induction logs 1/9/1996 5/8/1996 5
4/22/1997 4/1998 4/8/1999 4/18/2000 4/5/2001 10 5/17/2002 5/1/2003 Depth, in meters below land surface 4/26/2004 4/26/2005 4/20/2006 6/13/2007 15 4/30/2008 5/06/2009 4/9/2010 4/7/2011 Logs differ from each other over a range of approximately 14 millisiemens per meter. Given these differences, it is 20 difficult to determine if any real changes may be occurring 25 Screened 30 29.0 to 30.5 meters 0 10 20 30 40 50 Bulk conductivity, in millisiemens per meter Figure 5-1. Electromagnetic induction logs collected from monitoring well G-3611 from January 1996 to April 2011 prior to bulk conductivity adjustments, Miami-Dade County, Florida.
evaluation of the best overall alignment for a given dataset. the result of random instrumentation noise, but is slightly Multiple depths may be selected to computationally determine greater than the manufacturer-specified noise level of less than the best overall alignment, and the adjustments computed 0.5 mS/m (Mount Sopris Instrument Co., Inc., 2002); equip-for each individual log can be averaged. Logs could also be ment variation, drift, and calibration may have been contrib-aligned to the median bulk conductivity measured at selected uting factors. This random variation is much smaller than depths if desired. Depending on the goals of the research and the difference in change in bulk resistivity occurring when aquifer conditions, this method could also be used to establish saltwater enters previously freshwater-saturated materials.
a baseline to which all future logs would be corrected. Caution should be used when interpreting the resulting When using the correction procedures described, there TSEMIL datasets because apparent changes in bulk conduc-generally remains only about +/-1 to 1.5 mS/m of completely tivity are much smaller than the manufacturer-specified irregular variation between successive logs that cannot be precision of the equipment. One way to evaluate the quality removed (fig. 5-2). Even if perfect numerical alignment is of corrections applied to the time series of EMI logs is to achieved at one or two depths, the +/-1 to 1.5 mS/m of random compare the evident changes in bulk conductivity in the variation remains at all other depths. This variation is likely TSEMIL dataset to chloride concentrations in samples
80 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 0
EXPLANATION Variations in bulk conductivity near the land surface are observed in most log sets; these variations could G-3611 electromagnetic be caused by variations in water temperature or induction logs saturation of pore spaces near the land surface 1/9/1996 5/8/1996 5
4/22/1997 4/1998 4/8/1999 4/18/2000 These depth intervals may have 4/5/2001 become intruded with conductive 10 5/17/2002 water when the well was drilled.
The conductive water appears to 5/1/2003 Depth, in meters below land surface be slowly dissipating 4/26/2004 4/26/2005 4/20/2006 6/13/2007 15 4/30/2008 5/06/2009 4/9/2010 4/7/2011 20 With a few exceptions, the bulk conductivity of all logs agree within approximately 2 to 3 millisiemens per meter 25 Screened 30 29.0 to 30.5 meters 0 10 20 30 40 50 Bulk conductivity, in millisiemens per meter Figure 5-2. Time series electromagnetic induction log dataset that results from correction of errors in the calibration slope and offset. Monitoring well G-3611, January 1996 to April 2011, Miami-Dade County, Florida.
collected from the screen interval of the well. The chloride Considering the magnitude of corrections that have concentrations in samples collected from well G-3611 were been applied and all of the other factors that could potentially compared to the bulk conductivity measured at a depth of lead to differences between logs, the correlations observed 29.4 m (fig. 5-3). The chloride measurements and EMI logs between chloride and bulk conductivity (fig. 5-3) indicate collected during January and May 1996 have been excluded that the application of this method to the time series of EMI from the graph, because they were collected on different data produces reasonable results. Factors that could lead to dates. During 1997 to 2000, changes in chloride concentration differences include (1) a manufacturer-specified measure-were not reflected in the EMI logs, but the 15-mg/L increase ment accuracy of 5 percent of full scale, or 50 mS/m for in chloride concentration that occurred between 2001 and a full scale setting of 1,000 mS/m, (2) the relatively small 2002 corresponds to a 2-mS/m increase in bulk conductivity. changes in the chloride concentration in water samples, (3) the The gradual decrease in chloride concentration from 200 to magnitude of corrections applied to bulk conductivity that 170 mg/L that occurred between 2002 and 2011 corresponds are larger than the final range in bulk conductivity data at the to a gradual 4-mS/m decrease in bulk conductivity. depth 29.4 m, (4) the difference in EMI-log measured depth
Appendixes81 325 40 300 275 250 30 Chloride concentration, in milligrams per liter Bulk conductivity, in millisiemens per meter 225 200 175 20 150 125 100 10 75 50 EXPLANATION Chloride concentration 25 Bulk conductivity 0 0 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 Year Figure 5-3. Chloride concentrations in water samples collected from well G-3611 and the corrected bulk conductivity measured at a depth of 29.4 meters, Miami-Dade County, Florida.
and the depth of the screened interval, caused by the probe open interval of this well, which is 24.4 to 25.9 m (fig. 42B).
encountering the bottom of the well before a full response Similar comparisons of chloride concentration sampled and can be measured from the open interval and recorded, (5) the bulk conductivity measured are provided for most of the number of different EMI logging instruments and calibration TSEMI datasets published in this report (figs. 32B, 33B, 35B, methods that have been used, (6) the potential for chloride 38B, 41B, 43B, 44B, and 45B). In general, the changes in bulk concentration in water samples to change rapidly if drawn conductivity measured and chloride concentration samples are from well-connected pore spaces, while EMI logs would also similar. The depth intervals from which bulk conductivity data measure water trapped in finer pores that diffuses more slowly, were compiled for comparisons were often a little shallower and (7) the potential for water to be drawn in from outside the than the top of the screened interval, where chloride samples radius of investigation of the EMI logging equipment during were collected. This decision was made because the EMI water sampling. All of these factors could create large differ- probe typically encounters the bottom of the well before a full ences between the chloride concentration in water samples and response to aquifer materials can be recorded at the screened measured bulk conductivity. Yet some of the changes in bulk interval. The new well design (appendix 7) should allow better conductivity do correspond to changes in the chloride concen- comparisons of bulk conductivity measurements and chloride tration in water samples (fig. 5-3), and this correspondence is concentrations sampled from the screened interval because the not unique to this site. probe will be able to be lowered past the bottom of the screen The TSEMIL dataset from well G-3609 provides an and will be able to record a full response to aquifer materials example of the potential precision of this method. Prior to within the screened interval.
adjustment, the individual EMI logs were difficult to interpret The TSEMIL datasets collected in the study area (fig. 5-4). Once these logs were processed using the methods frequently indicate changes in bulk conductivity through time, described, however, the temporal changes in bulk conductivity from near the land surface to a depth of about 10 m. These in the depth interval 19 to 23 m became immediately evident changes may be caused by (1) differences in water temperature (fig. 42A). The changes in bulk conductivity occurring over time at shallow depths, (2) differences in the saturation in this depth interval generally agree with the changes in of pore spaces near the water table, and (3) the influence chloride concentration in water samples collected from the of saline and conductive purge water that may have soaked
82 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 0
EXPLANATION G-3609 2 electromagnetic induction logs 1/17/1996 5/24/1996 4
4/23/1997 4/1998 4/9/1999 6
4/13/2000 4/06/2001 5/20/2002 8 4/30/2003 4/23/2004 Depth, in meters below land surface 4/27/2005 10 4/24/2006 6/14/2007 4/30/2008 12 5/06/2009 4/13/2010 4/21/2011 14 16 18 20 22 Screened 24.4 to 25.9 meters 24 0 10 20 30 40 50 60 70 80 Bulk conductivity, in millisiemens per meter Figure 5-4. Electromagnetic induction logs collected from monitoring well G-3609 from January 1996 to April 2011, Miami-Dade County, Florida.
into the ground near the well. Frequently, where the chloride generally addresses only the offsets between logs. With the concentrations in water samples from the well are increasing, exception of the calibration coil error, it appears that the most the bulk conductivity of the shallow layers is also increasing. of the differences between individual logs can be addressed by Examination of TSEMIL datasets reveals that the removing the apparent offsets between individual logs. Any thickness of the saltwater interface in the Biscayne aquifer apparent temporal changes that could be a function of calibra-varies. The TSEMIL dataset collected in well G-3604 tion slope should be considered when using TSEMIL datasets (fig. 41A) shows a 1.7-m-thick transition between freshwater to evaluate possible temporal changes in aquifer salinity and water with a chloride concentration of 5,000 mg/L. The because the slope corrections generally are not considered TSEMIL dataset collected in well G-3699 (fig. 44A) indicates during the adjustment process. Slope differences frequently that the transition between freshwater and water with a can be ruled out as a significant factor when differences in chloride concentration of 9,700 mg/L is 6.2 m thick. aquifer salinity apparent in TSEMIL datasets and occurring Although both slope and offset are components of the below the saltwater interface are compared with the parts of calibration equation, the procedure described previously the TSEMIL datasets that are above the saltwater interface.
Appendixes83 References
- Type 2 - Model does not indicate a layer of saltwater occurring within the Biscayne aquifer (fig. 6-2), but model does indicate a decrease in resistivity that occurs ASTM International, 2007, Standard guide for conducting at or near to the depth of the base of the Biscayne aquifer.
borehole geophysical loggingelectromagnetic induction:
ASTM International D 6726-01 (reapproved 2007), 8 p.
- Type 3 - Model does not indicate any layer that is likely associated with the base of the Biscayne aquifer McNeill, J.D., 1986, Geonics EM39 borehole conductivity (fig. 6-3). Measurement indicates freshwater (resistiv-meter theory of operation: Geonics Limited, Technical Note ity > 15 ohm-m) throughout the depth modeled, and TN-20, 9 p., 1 addendum. modeled depth extends at least as deep as the base of the Biscayne aquifer.
McNeill, J.D., Bosnar, M., and Snelgrove, F.B., 1990, Reso-lution of an electromagnetic borehole conductivity logger
- Type 4 - Model does not indicate any layer likely to be for geotechnical and ground water applications: Geonics associated with the base of the Biscayne aquifer, but Technical Note TN-25, 28 p. a relatively conductive layer (resistivity < 15 ohm-m) occurs well below the base of the Biscayne aqui-Mount Sopris Instrument Co., Inc., 2002, 2PIA-1000 Poly fer. The top of this deeper conductive layer in some induction probe, 2EMA-1000 conductivity probe (2 instances corresponds to the base of the surficial EMB-1000 and 2ECM-1000) EMP-2493 and EMP-4493: aquifer (fig. 6-4).
Golden CO, Mount Sopris, 19 p.
There are also a few subtypes that can be described.
These are
- Subtype 1a models are similar to type 1 models in that Appendix 6. Evaluation of Depth of a conductive layer (resistivity < 15 ohm-m) occurs within the Biscayne aquifer; however, the thickness the Biscayne Aquifer by Using TEM of the conductive layer could not be determined, and Soundings its potential relation with the depth of the base of the Biscayne aquifer could not be evaluated.
Understanding the depth of the base of the Biscayne
- Subtype 1b models have a conductive layer (resistivity aquifer is important for creating maps of saltwater intrusion < 15 ohm-m) occurring within the Biscayne aqui-because saltwater may encroach along the base. At the outset fer, but the thickness of this layer extends below the of the current study, existing contour maps of the base of estimated depth of the Biscayne aquifer and into the the Biscayne aquifer were available for Broward County semiconfining unit of the surficial aquifer system.
(Fish, 1988) and Miami-Dade County (Fish and Stewart, 1991).
The TEM results from the current study were evaluated to deter-
- Subtype 3a models consist of a resistive layer or layers mine the extent of agreement between the depths of selected (resistivity > 15 ohm-m) within the Biscayne aquifer model layers and the depth of the Biscayne aquifer mapped by that may not fully penetrate the aquifer. It cannot be Fish (1988) and Fish and Stewart (1991) (appendix 4). ascertained whether resistive water extends fully to Wherever possible, the depth to the bases of the Biscayne the base of the Biscayne aquifer or beyond because the aquifer mapped by Fish (1988) or Fish and Stewart (1991) was thickness of the deepest resistive layer of these models interpolated at each TEM location and compared to the depths could not be determined.
of selected model layers of TEM soundings. The values of Appendix 4 provides (1) the resistivity of model layers, altitude below sea level provided by Fish and Stewart (1991) (2) the depths of the model layers, (3) the estimated depth of were converted to depth by using the altitude of the land the base of the Biscayne aquifer at each measurement location surface at each TEM sounding location interpolated from the from Fish and Stewart (1991) or Fish (1988), (4) the model data provided by a recent light detection and ranging (LIDAR) type or subtype, and (5) the difference between the depth of the study (Florida Division of Emergency Management, 2009). base of the Biscayne aquifer modeled from the TEM sounding, The contour intervals of Fish and Stewart (1991) and the if evident, and that estimated from Fish and Stewart (1991).
Although these relations are subject to interpretation 2008 LIDAR study were 3.0 and 0.6 m, respectively. The rela-because they rely on previously mapped aquifer depths, this tions between modeled depths and aquifer depths interpolated information may be used to assist geologic mapping efforts.
from the contours of Fish (1988) or Fish and Stewart (1991)
Appendix 4 provides a summary of the types of relations fall into four general categories: between the estimated depth of the base of Biscayne aquifer
- Type 1 - Model indicates a layer of saltwater and the depth of selected model layers. Where such compari-(resistivity 15 ohm-m) occurring within the Biscayne sons are possible, table 6-1 provides the minimum, maximum, aquifer (fig. 6-1). The bottom of this model layer and average differences between the estimated depth of the appears to correspond closely with the depth of the base of the Biscayne aquifer and the depth of the selected base of the Biscayne aquifer. model layers.
84 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A. MIA231 B. MIA231 1,000 0 Estimated depth of base of Biscayne aquifer 100 50 Apparent resistivity, in ohm-meters Depth, in meters 10 100 1 150 0.001 0.01 0.1 1 10 1 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of high frequency saltwater saturated materials data Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data and error Resistivities > 15 ohm-m indicate marker freshwater saturated materials High frequency data and error Model fit of ultra high frequency marker data Figure 6-1. Type 1 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
Of the 79 TEM soundings collected, 3 were unusable as The average difference was +/-2.4 m. Differences could result a result of anthropogenic interference with the measurements. from (1) imprecision of depth interpolations from contours, The remaining 76 were categorized as type 1 (30), type 1a (9), (2) variation in the modeled thickness of the conductive layer type 1b (2), type 2 (17), type 3 (7), type 3a (1), and type 4 (10) depth resulting from measurement imprecision or model (appendix 4 and appendix 6, table 6-1). Only the 47 type equivalency, (3) depressions or highs in the paleosurface 1 and 2 models have a model layer interface that potentially over which the Biscayne aquifer was deposited that were not can be compared to the depth of the base of the Biscayne captured in the contours of Fish (1988) or Fish and Stewart aquifer (figs. 6-1 and 6-2). The type 1 and type 2 relations (1991), (4) intrusion of a portion of the semiconfining unit are summarized in table 6-1. Of the 47 type 1 and 2 relations, of the surficial aquifer system by saltwater, (5) imprecision 30, 53, and 81 percent of the models had a model-layer of land-surface altitudes, or (6) potential difficulties in interface that corresponded to the previously mapped base of interpreting the depth of the Biscayne aquifer from available the Biscayne aquifer within 1.0, 2.0, and 4.0 m, respectively. stratigraphic information.
Appendixes85 A. MIA108 B. MIA108 1,000 0 Estimated depth of base of Biscayne aquifer 100 50 Apparent resistivity, in ohm-meters Depth, in meters 10 100 1 150 0.001 0.01 0.1 1 10 1 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of ultra high saltwater saturated materials frequency data Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data Resistivities > 15 ohm-m indicate freshwater saturated materials Masked data Figure 6-2. Type 2 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
The largest differences between the estimated depth of to detect. Five of the seven sites where the differences ranged the base of the Biscayne aquifer and the selected model layer between 5 and 7.7 m are in the Model Land area. Fish and depth were 6.9, and 7.7 m, which occurred at measurement Stewart (1991, p. 38) used only three boreholes in this area for locations MIA122 and MIA202, respectively. The modeled their mapping effort, and the sparse distribution of boreholes layer thicknesses determined for measurement MIA202 in their mapping effort may have failed to identify variations were considered very good (Fitterman and Prinos, 2011). in the depth of the base of the Biscayne aquifer.
Measurement MIA202 may, therefore, indicate the pres- All of the type 3 and type 4 models determined from ence of an isolated but deep topographic depression in the measurements in the Model Land area and a few miles north paleosurface over which the Biscayne aquifer was deposited, of it indicate a decrease in resistivity occurring between or it may indicate that the differences in resistivity occurring depths of 11.8 and 18.9 m. These models have a highly near the base of the Biscayne aquifer were not large enough resistive (184-709 ohm-m) first layer and a less resistive
86 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater A. MIA208 B. MIA208 1,000 0 Estimated depth of base of Biscayne aquifer 100 50 Apparent resistivity, in ohm-meters Depth, in meters 10 100 1 150 0.001 0.01 0.1 1 10 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of high frequency saltwater saturated materials data Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data and Resistivities > 15 ohm-m indicate error marker freshwater saturated materials High frequency data and error Model fit of ultra high frequency marker data Masked data Figure 6-3. Type 3 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
(21.1-60.0 ohm-m) second layer. The decrease in resistivity a recent USGS and FPL cooperative study (Wacker, 2010),
does not appear to be associated with the base of the Biscayne indicated flow zones at depths of approximately 14 to 17 m.
aquifer because there is ample hydrostratigraphic information Flow zones also were identified in wells G-3939 and G-3940 available in this area to place the depth of the base of the at depths of approximately 10 to 11 m. If laterally persistent, aquifer between 23 and 29 m. Hydrostratigraphic information these flow zones and perhaps the interaction of these flow includes logs from recently installed monitoring wells and zones with minor amounts of intruded saltwater (less than that numerous proximal type 1 and type 2 TEM models from normally associated with the saltwater front) may account which the depth of the base of the Biscayne aquifer can be for the changes in resistivity detected in the type 3 and interpreted. Geophysical logs collected in well G-3946, type 4 models of TEM soundings.
installed during this study (table 7-1), and test core holes TEM sounding MIA240 was a two-layer type 3 model G-3938, G-3939, and G-3940 (appendix 1), installed during that indicated a reduction in resistivity occurring at a depth
Appendixes87 A. MIA124 B. MIA124 1,000 0 100 50 Apparent resistivity, in ohm-meters Estimated depth of base of Biscayne aquifer Depth, in meters Estimated depth of base of surficial aquifer system 10 100 1 150 0.001 0.01 0.1 1 10 1 10 100 1,000 Time, in milliseconds Resistivity, in ohm-meters EXPLANATION Resistivities < 10 ohm-m indicate Model fit of ultra high frequency data saltwater saturated materials Resistivities 10 - 15 ohm-m are Model of depth and considered indicative of the leading resisitivity edge of the saltwater front Ultra high frequency data and error marker Resistivities > 15 ohm-m indicate freshwater saturated materials Figure 6-4. Type 4 relation between the depths of model layers and the depth of the base of the Biscayne aquifer.
(A) Graph of apparent resistivity versus time; (B) modeled depth and resistivity. Graph modified from Fitterman and Prinos (2011).
of 72.9 m. Models of measurements MIA241 and MIA242, The conductive layers identified in type 4 models collected in the same area, also indicated decreases in resis- occurred at depths ranging from 49.6 to 98.1 m. These layers tivity occurring at depths of 65.1 and 76.4 m, respectively. correspond within 29 m to the base of the surficial aquifer The depth of the base of the surficial aquifer in this area is system in 7 of the 10 type 4 models. It is unknown if the estimated to be 86 m from the contour map of Fish (1988). base of the surficial aquifer varies this extensively because the distribution of boreholes used for the mapping effort was Considering that the contour in this area was based on only relatively sparse (Fish, 1988; Fish and Stewart, 1991). The one borehole and that the depth of the base of the surficial conductive layers identified in the remaining three type 4 aquifer may vary, the decreases in resistivity indicated by the models are at depths ranging from 35 to 45 m below the models of these TEM soundings may be associated with the estimated depth of the base of the surficial aquifer system and depth of the base of the surficial aquifer. may correlate to a unit within the Hawthorn Group.
88 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Table 6-1. Types of model relations and comparisons between the estimated depth of the base of the Biscayne aquifer in Miami-Dade and Broward Counties, Florida, and the depth of the selected model layers.
[NA, not applicable]
Relations between selected model Difference between estimated depth of the Percentage of relations for which the surfaces and estimated depth of base of the Biscayne aquifer and depth of estimated aquifer depth and selected layer depth base of Biscayne aquifer applicable model surface are within:
Number of Relation type relations of Maximum Minimum Average 1 Meter 2 Meter 4 Meter this type 1 30 7.7 0.1 2.3 33 60 80 1a 9 NA NA NA NA NA NA 1b 2 NA NA NA NA NA NA 2 17 5.6 0.1 2.7 24 41 82 3 7 NA NA NA NA NA NA 3a 1 NA NA NA NA NA NA 4 10 NA NA NA NA NA NA 1 and 2 combined 47 7.7 0.1 2.4 30 53 81 References Appendix 7. Description of Installation and Construction of Fish, J.E., 1988, Hydrogeology, aquifer characteristics, and groundwater flow of the surficial aquifer system, Broward Saltwater Front Monitoring Wells County, Florida: U.S. Geological Survey Water-Resources Investigations Report 87-4034, 80 p. Site Selection and Depths of New Monitoring Fish, J.E., and Stewart Mark, 1991, Hydrogeology of the surfi- Wells cial aquifer system, Dade County, Florida: U.S. Geological Sites for new saltwater monitoring wells were selected Survey Water-Resources Investigations Report 90-4108, to fill gaps in the existing salinity monitoring network, based 50 p., 11 sheets.
on a review of the spatial coverage provided by existing Fitterman, D.V., and Prinos, S.T., 2011, Results of time- monitoring wells and surface geophysical data. The eight domain electromagnetic soundings in Miami-Dade and new wells were named G-3885, G-3886, G-3887, G-3888, southern Broward Counties, Florida: U.S. Geological G-3946, G-3947, G-3948, and G-3949 (fig. 8). Some of Survey Open-File Report 2011-1299, 289 p. the new monitoring wells have sample tubes installed to collect water-quality samples in flow zones above or below Florida Division of Emergency Management, 2009, Miami- the saltwater interface, and A, B, C, D, and S Dade County 2 ft contour lines: Tallahassee, FL, Florida suffixes are added to the well name to differentiate between Division of Emergency Management, Shapefile, accessed the primary well and the sample tubes (table 7-1). In addition February 10, 2011, at http://www.floridadisaster.org/gis/ to the installation of new saltwater monitoring wells, the study index.asp. also included the collection of core and borehole geophysical logs (appendixes 8 and 9).
Wacker, M.A., 2010, Tools and data acquisition of borehole geophysical logging for the Florida Power and Lights Com-pany Turkey Point Power Plant in support of a groundwater, Drilling and Coring surface-water, and ecological monitoring plan, Miami-Dade County, Florida: U.S. Geological Survey Open-File Report Monitoring wells were drilled and constructed in two 2010-1260, 5 p., appendixes. phases. Four wells were drilled between June 30, 2009, and
Table 7-1. Construction and logging information from new wells installed in Miami-Dade County, Florida, during 2009-2011.
[NGVD 29, National Geodetic Vertical Datum; m, meters; >, greater than; S/cm, microsiemens per centimeter; cm, centimeters; NA, not applicable]
Latitude Number Longitude Base of Bottom (North), in Depth to Screen of Internal (West), in Altitude Altitude of Total depth Biscayne of tailpipe Local USGS station End date of degrees, water with interval separate diameter Description* degrees, of ground top of cored from aquifer from land identifier number construction minutes, > 5,000 from land stages of PVC pipe minutes, and surface (m) casing (m) surface (m) from land surface and µS/cm (m) surface (m) needed to (cm) seconds surface (m) (m) seconds log well G-3885 Primary well 253253080221201 8/18/2009 25-32-53.1 080-22-12.7 2.12 1.89 27.74 24.63 NA 23.16-24.69 26.21 1 5.08 G-3886 Primary well 253527080195401 10/2/2009 25-35-27.9 080-19-54.2 3.1 2.91 33.22 27.74 NA 26.21-27.74 30.78 1 5.08 G-3887A Primary well 253924080174601 9/25/2009 25-39-24.7 080-17-46.8 3.18 2.96 40.84 36.52 23.38 24.38-25.91 39.62 1 5.08 G-3887B Sample tube 253924080174602 9/25/2009 25-39-24.7 080-17-46.8 3.18 Not 40.84 36.52 23.38 19.51-21.03 22.56 1 2.54 Surveyed G-3888A Primary well 254542080145901 10/5/2009 25-45-42.7 080-14-59.8 4.31 4.17 45.35 41.76 29.57 31.55-34.59 43.74 2 5.08 G-3888B Sample tube 254542080145902 10/5/2009 25-45-42.7 080-14-59.8 4.31 Not 45.35 41.76 29.57 39.62-41.15 42.67 2 1.91 Surveyed G-3888C Sample tube 254542080145903 10/5/2009 25-45-42.7 080-14-59.8 4.31 Not 45.35 41.76 29.57 22.86-27.43 28.96 2 1.91 Surveyed G-3946D Primary well 252431080261001 6/22/2010 25-24-30.7 080-26-09.7 1.09 1 26.64 20.09 16.73 18.90-20.42 26.52 1 5.08 G-3946S Sample tube 252431080261002 6/22/2010 25-24-30.7 080-26-09.7 1.09 1.01 26.64 20.09 16.73 15.85-16.76 16.76 1 2.54 G-3947 Primary well 255011080124501 7/16/2010 25-50-11.3 080-12-45.4 3.57 3.48 69.49 54.01 None 51.82-54.86 60.96 1 (below 5.08 23.77 m)
G-3948D Primary well 255515080103601 10/13/2010 25-55-14.9 080-10-36.2 3.62 3.54 84.8 76.2 65.78 72.24-74.07 83.21 6 5.08 G-3948S Sample tube 255515080103602 10/13/2010 25-55-14.9 080-10-36.2 3.62 Not 84.8 76.2 65.78 35.51-37.03 37.03 6 2.54 Surveyed G-3949D Primary well 255733080195601 1/31/2011 25-57-33.6 080-09-56.5 3.75 3.62 106.46 84.04 NA 66.14-67.67 99.06 7 5.08 G-3949I Sample tube 255733080195602 1/31/2011 25-57-33.6 080-09-56.5 3.75 Not 106.46 84.04 NA 44.44-45.96 46.01 7 2.54 Surveyed G-3949S Sample tube 255733080195603 1/31/2011 25-57-33.6 080-09-56.5 3.75 Not 106.46 84.04 NA 15.24-16.76 16.81 7 2.54 Surveyed Monitoring wells with sample tube listed under description were constructed in the same borehole as the primary well with the same local identifier prefix, to obtain water-quality samples only.
Appendixes89
90 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater October 5, 2009, and the remaining four wells were drilled in core boxes and the approximate depth of retrieval, if known, between June 30, 2010, and February 3, 2011. A USGS Florida was indicated with wood blocks. Airlifting was considered Water Science Center hydrologist supervised the coring, data complete when the borehole was free of obstructions and collection, and well construction at each site. Decisions were the water from the borehole was free and clear of suspended made during drilling, regarding the need for additional lengths solids. Water clarity is an important consideration for optical of surface casing and the stability of the borehole. Borehole borehole image (OBI) logging.
geophysical logs were collected in stages (table 7-1) during At some sites, sand layers within the aquifer bridged the drilling at some sites. A steel casing was used to keep the across the borehole to create an obstruction. Bridging and borehole open to total depth due to sand infilling the borehole. infilling with sand required that these boreholes be drilled, Borehole drilling began at each site using a logged, and constructed in stages (table 7-1). Some of the 35.6-cm-diameter auger to drill a hole to the top of the first geophysical logs, such as the digital OBI logs, were incom-stable geologic unit, such as a well cemented limestone or plete because of the obstructions caused by the bridging of sandstone unit. A schedule 2, polyvinyl chloride (PVC) surface sand layers in these boreholes. In well G-3949, numerous casing with a 25.4-cm inside diameter was installed in the sand bridges were encountered during drilling.
hole produced by the auger and was grouted into place. The well was cored from the approximate top of the bedrock using Borehole Geophysical Logging Prior to Well a wire-line coring system to collect a 10.2-cm-diameter core samples to a depth below the base of the Biscayne aquifer and Construction into the uppermost part of the underlying semiconfining unit Geophysical logging was performed by the USGS in as determined by the USGS onsite hydrologist. Coring was each of the eight boreholes. Geophysical logs similar to those completed in 1.5-m intervals, and the time required to drill described in Wacker and Cunningham (2008) were collected to each foot (0.3 m) was recorded in a field log. Each 1.5-m core help identify (1) the base of the Biscayne aquifer, (2) zones of interval segment was brought to the surface; the core segment higher permeability, and (3) depth to water with conductivity, was removed from the core barrel by the USGS onsite compensated at 20 °C, greater than 5,000 µS/cm, if found hydrologist and placed in a 1.5-m-long PVC core-recovery within the boreholes. This information was used to determine tray while maintaining the correct vertical stratigraphic the optimal design specifications for the new monitoring wells.
orientation. The core segment was washed to remove drilling These new monitoring wells were designed to monitor the cuttings and fluids and was placed in a 0.6-m-long cardboard deepest preferential groundwater flow zone identified within core box with wooden blocks marked with the drillers depth the formations that comprise the Biscayne aquifer. Additional placed at the bottom of each core segment. The core segment sample tubes were added if the geophysical logs indicated was then marked by using paint pens with two continuous other permeable zones of interest. Geophysical logging vertical lines (one black and one red) running parallel to the commenced within about 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of completion of airlifting long axis of the cylindrical core samples. When the core is to allow suspended sediment in the borehole fluid column to oriented in the correct vertical orientation with respect to the settle. The 24-hour waiting period was generally sufficient to strata in the aquifer, the red line is on the right side of the produce clear formation fluid in the borehole required for the core and the black line is on the left. This marking convention OBI log. In some wells, geophysical logs (caliper, gamma, prevents inadvertent inversion of core segments. The length of spontaneous potential, single point resistance, electromagnetic the core segment recovered from each 1.5-m core interval was induction, and full waveform sonic) were run immediately entered in a field log. after the airlift development because these logs are not A liquid polymer mud was added as necessary to the affected by borehole water clarity.
drilling fluid to facilitate collection of unconsolidated sand and soft sediment in the core barrel and to allow their extrusion Borehole Image Logging from the barrel at the surface. The polymer mud also provided lubrication and facilitated the removal of cuttings. The At each borehole drilled for this study, two types of polymer breaks down within a few days and is easily removed geophysical borehole imaging tools were used: the Mount from the column of borehole fluid during a borehole purging Sopris OBI MK-IV digital OBI tool and a Mount Sopris process called airlifting. Once coring was completed to the ABI-40 digital acoustic borehole imaging (ABI) tool. The desired total depth below the Biscayne aquifer, the wire-line OBI log was collected first, using 95 percent light and coring casing was removed. The borehole was prepared for 720 turns (or every half degree of circumference), and logging by evacuating loose clay, silt, and sand to cobble-sized was sampled vertically every 0.82-mm of depth. Then the (up to 7.6 cm diameter) material from the borehole with an ABI-40 digital acoustic borehole imaging (ABI) log was airlift device constructed by the drilling contractor. As water collected using 288 turns (or every 1.25 degrees of circumfer-was purged from the borehole by using this device, it was ence) and was sampled vertically every 1.68 mm of depth.
replaced by water from the aquifer. This flow aids removal Both OBI and ABI tools acquired data while logging upward of drilling fluids and improves water clarity. Any noteworthy from the bottom of the borehole to the land surface or from the samples brought to the surface during airlifting were archived bottom of casing if the borehole was logged in stages.
Appendixes91 Borehole Fluid and Caliper Logging an acoustic signal transmitted at 15 kilohertz (kHz; used for porosity calculations) and one transmitted at 1 kHz (used A Mount Sopris Idronaut 303 (Mount Sopris 2IFA-1000) for relative permeability estimations). The full waveform water-quality tool was used at each site to collect logs of sonic logs were not collected from wells that were logged fluid temperature, conductivity compensated at 20 °C , pH, in multiple stages when the length of logging stage was less dissolved oxygen (in percent), and oxidation reduction poten- than 6.1 m because the 3.0-m tool length would not provide tial. The conductivity measured by this probe is not the same useful information in a short interval. The full waveform sonic as specific conductance because specific conductance is typi- logs were processed by using Log CruncherTM software. Log cally normalized to a temperature of 25 °C. The water-quality Cruncher is used to determine the mean primary compres-tool acquired data while logging upward and downward in the sional wave and Stoneley wave velocities. The compressional borehole. After the first four wells were completed, and before wave velocity is used as input into the Raymer-Hunt porosity construction of the last four was begun, the water-quality tool equation for calculation of sonic porosity (Raymer and was returned to the manufacturer for repairs of a sensor and for others, 1980). Sonic porosity values calculated from compres-re-calibration. The water-quality tool was fully calibrated and sional wave velocities are typically higher than whole-core functioned properly at all sites. In addition, the water-quality laboratory porosity measurements. Known values of tool calibration was checked with a separate and independently laboratory-measured porosity of rock cores were not available calibrated conductivity meter during logging. to calibrate a computed porosity curve. The amplitude of the At sites where the borehole was filled with freshwater, Stoneley wave also was measured from the receiver closest a Mount Sopris 2FSB-1000 fluid probe, which was attached to the transmitter (receiver 1). The Stoneley wave amplitude to the bottom of a Mount Sopris 2CAA-1000 three-arm has a predictable qualitative relation to permeability, which caliper tool, was used to acquire fluid temperature and can be used to estimate a qualitative permeability of the rock resistivity measurements while logging downward from surrounding the borehole. Generally, low amplitudes can land surface. Temperature and resistivity were automatically represent relatively high permeability, and high amplitudes can used to compute fluid conductivity and specific conductance represent relatively low permeability. The computed value, (appendix 8). Fluid probe data were used for comparison with therefore, can be used in a qualitative and conservative sense the water-quality tool when available. Caliper logging with to estimate zones of relatively high and low permeability.
the caliper tool was then performed to determine the borehole diameter. These logs were collected in an up-hole direction. Flowmeters Flowmeter logging of each borehole was completed Induction, Natural Gamma-Ray, Spontaneous under both ambient (static) and dynamic (pumping) condi-Potential, and Single-Point Resistance Logging tions. Three different types of flowmeters were used during the study because of the variability in borehole fluid conditions.
After the caliper log was collected, logs were collected Saline fluids are more conductive and appear to have an using a Mount Sopris 2PIA-1000 electromagnetic induc-effect on the performance of the electromagnetic flowmeter tion tool, an HLP-2375/S natural gamma-ray tool, and and, to a lesser degree, on the performance of the heat-pulse a combined spontaneous potential (SP) and single-point flowmeter. The spinner flowmeter is not affected by the resistance (SPR) tool. Induction logs were collected in the conductivity of the borehole fluid. Each borehole was pumped up-hole and down-hole directions. The natural gamma-ray using a 5.08-cm-intake-diameter centrifugal water pump with log was collected in an up-hole direction, and the sponta- the suction line placed below the water table within the open neous potential (SP) and single-point resistance (SPR) logs borehole. Flow rates were measured by timing the rate at were collected in a down-hole direction. The Mount Sopris which discharge water filled a 75.7-L container and are shown 2PIA-1000 electromagnetic induction tool was calibrated on each log heading (appendix 8). Pumping rates during as described in preceding sections of this report. A final geophysical logging ranged from 121 to 477 L/min. Rates electromagnetic induction log was collected in each of the varied depending on depth to water and length of discharge completed 5.1-cm-diameter monitoring wells. The natural hose. Flowmeter logs were not collected from any boreholes gamma-ray tool and SP/SPR tool do not require calibration (G-3888, G-3947, G-3948, and G-3949) with geophysical and provide relative values that can be compared with other logging intervals less than 6.1 m in length.
logs collected with the same tool. Once the image and caliper logs were collected at each borehole, a draft of these logs was plotted in the field to deter-Full Waveform Sonic mine optimum depths for the collection of stationary measure-ments of vertical borehole fluid flow using the flowmeters. A Upon completion of induction, natural gamma-ray, Mount Sopris HPF-2293 heat-pulse flowmeter with an 18-cm SP, and SPR logging, a Mount Sopris 2SAA-1000/F full petal diverter was set at each predetermined depth, and at least waveform sonic tool log was collected from each borehole. three measurements were collected at each stationary depth Two logs were collected by using the sonic tool: one with under ambient borehole fluid-flow conditions.
92 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater Following logging with the heat-pulse flowmeter, a tip of the induction logging tool usually encounters the bottom Century Geophysical 9721 electromagnetic flowmeter was of the well before a full response to materials at the aquifers used to log by trolling up and down the borehole to create a base can be achieved. To improve the quality of data collected, continuous log of vertical borehole fluid flow under ambient the new monitoring wells incorporated several design features conditions. The electromagnetic flowmeter also contained a (fig. 7-1) not previously implemented in the USGS network sensor to measure borehole fluid temperature and resistivity, in this area: (1) additional casing that extended below the which were recorded. After the ambient borehole fluid flow screen and somewhat deeper than the base of the Biscayne was measured while trolling, a centrifugal pump was used aquifer, (2) installation of secondary filter packs in zones of to draw water from the well at a constant rate. Once the flow high porosity, and (3) installation of secondary sampling tubes and drawdown stabilized, the electromagnetic flowmeter log in selected secondary filter packs. By adding additional casing was collected in the borehole under pumping conditions. The below, a full response can be recorded within the screened electromagnetic flowmeter acquired stationary pumping flow interval. The additional casing can also allow measurement of measurements at the same depths as those acquired by the changes occurring near the top of the semi-confining unit of heat-pulse flowmeter under ambient conditions. The electro- the surficial aquifer to determine if saltwater also is intruding magnetic flowmeter also provided logs of fluid temperature into these sediments.
and resistivity (appendix 8).
Large solution cavities in the limestone of the Biscayne In some boreholes that were logged in stages, the lowest aquifer likely would allow the cement grout of the annular stage was logged with either a Mount Sopris FLP-2492 seal to flow into the formation. This grout could prevent spinner flowmeter or an electromagnetic flowmeter during formation water from entering the 20- to 100-cm radius of pumping to determine flow zones. Ambient flow informa-tion was not collected in wells where the upper part of the investigation of the induction logging probe. The installation borehole was cased because there would not be a head of secondary filter packs at depths where large solution difference between the lower and upper flow zones to cause cavities occur allows formation water to flow unimpeded in ambient flow. close proximity to the well casing so that the formation water can be measured by the induction probe. Small-diameter sample tubes were installed in some of the secondary filter Geophysical Log Analysis packs so that the water in highly transmissive flow zones could be sampled.
Following acquisition of all geophysical logs in the Historically, drill cuttings were used to evaluate the field, the raw log data were processed and displayed by using stratigraphy and to help determine the depths of the intakes of Advance Logic Technology, WellCAD version 4.3, and were some of the monitoring wells used for collection of TSEMIL saved in Adobe Systems Incorporated Portable Document datasets. Evaluations of drill cuttings alone could result in a Format (PDF) at 1:48 scale (appendix 8). Final monitoring- well intake too deep to provide water samples from the depth well completion zones are shown on the final log montage interval where there are changes in bulk conductivity. For with depths relative to land surface. example, this situation occurred at well G-3701 (fig. 33A).
The geophysical logging during this study allowed the identifi-Well Completion cation of the deepest flow zones within the Biscayne aquifer so that the screened interval of the 5.1-cm-diameter monitoring By using the information provided by geophysical and well could be placed in this flow zone. Additional casing was water-quality logging (appendix 8), the monitoring wells were added below the screen to ensure that the induction tool would designed to (1) penetrate the full thickness of the aquifer and be able to record data across the boundary between the base of a shallow depth below it, into the upper portion of the semi- the aquifer and the semi-confining unit of the surficial aquifer.
confining unit of the surficial aquifer, (2) provide samples In some instances, such as for well G-3949, the tailpipe from the deepest flow zone occurring within the formations extends to a much greater depth below the screened interval so that comprise the Biscayne aquifer, and (3) allow sampling of that identified zones of weak flow within the semi-confining shallower flow zones or saltwater interfaces through sample unit of the surficial aquifer can be monitored. Secondary tubes. Table 7-1 provides well construction information sampling tubes were installed in five of the eight boreholes.
for the eight wells installed during this study. The depth to Once the well design was completed, construction began water of conductivity, compensated at 20 °C, greater than by backfilling the borehole with 20-30 grade sand to the 5,000 µS/cm also is provided because water of this conduc- designed depth of the bottom of the added casing. Then the tivity generally has a chloride concentration of 1,000 mg/L well casing and screen were assembled and inserted into the or greater. A chloride concentration of 1,000 mg/L has been well. More fine sand was added to a depth about 1.2 m below used historically for mapping the inland extent of saltwater in the screen, and then a layer of time-release bentonite pellets southeast Florida. and sand was installed that extended to within approximately Many of the pre-existing monitoring wells were designed 0.6 m of the bottom of the screen. A filter pack consisting of such that the bottom of the well would be at about the same pea gravel was used to fill the screened interval from 0.6 m depth of the base of the Biscayne aquifer. In this design, the below the interval to 0.6 m above the top of the interval. Then
Appendixes93 Depths of screen intervals, and seals are based on results of geophysical logging Locking well plug Possible surface casing 1-meter-diameter depending on materials cement well pad at surface about 0.3 meter thick 20- to 30-centimeter-diameter metal Pea gravel to allow drainage protective well cover with bolt-down lid of protective cover Sample tube for collecting water Casing: 5-centimeter-diameter, samples from flow zones schedule 40 PVC, screw-together flush joints with o-ring seals Solution cavities 15- to 20-centimeter-diameter hole Secondary filter pack. Annular seal Sand or pea gravel fill to neat cement prevent cement from running into formation Bentonite pellet seal minimum 0.3 meter thick Screen- 5-centimeter diameter, PVC, 1.5-meters long, screw-together flush joints with o-ring seal Sand seal 0.6 meter thick Filter pack pea gravel Encroaching sea water Additional length of casing to allow full response from logging equipment BASE OF AQUIFER Hole may be drilled deeper to explore hydrology and then backfilled Well plug Figure 7-1. Illustration showing design of new monitoring wells installed during the study to monitor saltwater intrusion into the Biscayne aquifer, Miami-Dade County, Florida.
94 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater successive layers of sand and bentonite pellets were added to create a seal above the filter pack that would prevent grout from Appendix 9. Hydrostratigraphic filling the filter pack. In the deeper wells (G-3947, G-3948, and Analysis G-3949), the material was added by using a 2.5-cm-diameter PVC tremie pipe. The annular seals of wells were grouted in Continuously drilled core samples from the eight new stages. A 190-L barrel (about 4 bags) of grout was added at a monitoring sites and related borehole geophysical logs were time, and this grout was allowed to set overnight. If a sample examined in the USGS core laboratory in Davie, Florida.
tube was installed to monitor a flow zone, the previously Geologic, geophysical, and hydrologic data from the eight described procedure for creating a filter pack was used to boreholes form the fundamental basis for a generalized complete that interval. If a sample tube was not installed in the hydrostratigraphic framework of the surficial aquifer in central identified high flow zone, it was filled with a layer of coarse to northern coastal Miami-Dade County, which is described (6-20 grade) sand that extended about 1 m above and below herein. The information obtained from the new wells was used the flow zone. This layer of sand was capped with a layer of to map on a two-dimensional section the lithostratigraphic and bentonite pellets and grout to prevent the movement of water in hydrostratigraphic units (fig. 9-1). The lithology and extent of the annular space. Pea gravel filter packs, sample tubes, seals, the lithostratigraphic units were determined by examination and grout were installed as necessary to complete the well of continuously drilled cores and borehole-geophysical logs installation. Near the surface, a grout layer was added to within (especially digital optical borehole wall images).
a few feet of land surface to seal the well from surface water.
After the grout was set, the manhole was constructed by adding sand above the grout to the base of the manhole to allow for Correlation of Lithostratigraphy and drainage. Then a concrete pad was constructed. Hydrostratigraphy of Eight New Boreholes After the wells were completed, Miami-Dade County surveyed the top of each casing and the manhole, and a final Correlation of the basic lithostratigraphy represented electromagnetic induction log was run in each completed in the eight boreholes drilled for this study is shown in monitoring well. Field notes were collected during drilling, figure 9-1. Zones of groundwater flow within and delimiting logging, and construction, and a PDF file was then made of the base of the Biscayne aquifer in these eight wells were all logs. Well information was entered into the USGS Ground defined by using the results of the examination of pore systems Water Site Inventory (GWSI) system for future reference, and in lithologic cores and in digital optical borehole wall images the geophysical logs were archived for future use. and the evaluation of flowmeter logs combined with borehole-fluid conductivity and temperature log data. Interpretations of this information indicate that the surficial aquifer within the study consists mostly of the Tamiami Formation, Fort References Thompson Formation, Miami Limestone, and the intermediate confining unit comprised of the Stock Island Formation Raymer, L.L., Hunt, E.R., and Gardner, J.S., 1980, An (figs. 6 and 9-1). The hydrogeologic cross section displayed improved sonic transit time-to-porosity transform, paper P, in figure 9-1 is oriented oblique to the strike of depositional in 21st Annual Logging Symposium Transactions: Society facies belts of the Pliocene-Pleistocene depositional systems of Professional Well Log Analysts, 12 p. that comprise the Stock Island Formation, Tamiami Formation, Fort Thompson Formation, and Miami Limestone. Thus the Wacker, M.A., and Cunningham, K.J., 2008, Borehole geo- lithologies encountered in the southern boreholes represent physical logging programIncorporating new and existing more shoreward facies belts that are oriented generally parallel techniques in hydrologic studies: U.S. Geological Survey to paleoshorelines, and the northern boreholes intersect facies Fact Sheet 2008-3098, 4 p. belts mostly parallel and proximal to the Pliocene-Pleistocene paleoshelf margins.
Until recently, the Stock Island Formation was only defined in the western Florida Keys (Cunningham and Appendix 8. Geophysical Logs others, 1998), but is now recognized in Miami-Dade County at the G-3948 and G-3949 test boreholes (fig. 8). In the two Geophysical logs collected in the eight new wells were test boreholes, the lithology of the Stock Island Formation is evaluated using WellCADTM software. WellCADTM files are characterized by skeletal fragment, planktonic foraminiferal provided as supplemental files. AdobeTM Portable Document lime packstone and grainstone, which in some cases is very Format (PDF) files are also provided in the supplement files, quartz-sand rich. The Stock Island Formation occurs subjacent but the ability to view all logs in detail is limited by this format. to the Tamiami Formation in the test boreholes G-3948 and G-3949 (fig. 9-1), but on a regional scale is generally See supplemental files in the folder http://pubs.usgs.gov/ equivalent to the Tamiami Formation. In Broward County, sir/2014/5025/appendix/sir2014-5025_appendix_08. the Stock Island Formation is shown on the Hillsboro Canal
Appendixes95 B 66.9 km B' SOUTH 16.9 km 6.1 km 8.0 km 12.6 km 9.0 km 10.0 km 4.3 km NORTH G-3946 G-3885 G-3886 G-3887 G-3888 G-3947 G-3948 G-3949 NGVD 1929 NGVD 1929
?
?
-10 -10
?
?? ??
?? Surficial
?? Aquifer
? System
-20 -20
?
Biscayne
-30 ? Aquifer ? -30
??
?
Altitude, in meters relative to NGVD 1929 Altitude, in meters relative to NGVD 1929
?
?
-40 -40
?
?
-50 -50
?
-60 Se ? -60 mi co Un nfin it ing
-70 -70
?
-80 -80 Intermediate 80°40' 80°20' 80°00' Confining 26°00' B' ? Unit LEE COUNTY BROWARD COUNTY
-90 ! -90 OCEAN MIAMI-DADE COLLIER COUNTY
-100 COUNTY -100 ATLANTIC 25°40' !
! EXPLANATION
! Soil or fill or both Limestone Miami Limestone Quartz sand
! Fort Thompson Formation Sandstone B
Tamiami Formation No recovery 25°20' Stock Island Formation Flow zone Not interpreted Slotted casing 0 5 10 KILOMETERS EXPLANATION Hydrostratigraphic boundary Cased well B B' 0 5 10 MILES Cross section Lithostratigraphic boundary Drilled and then
! New USGS salinity backfilled monitoring well ? Lithology uncertain Figure 9-1. Illustration showing the cross section oblique to depositional strike of the upward transition from Pliocene-to-Pleistocene mixed carbonate-siliciclastic ramp to platform that comprise the surficial aquifer system and intermediate confining unit of central and northern coastal Miami-Dade County. The southern part of the cross section is substantially west of the present-day and Plio-Pleistocene shelf margin as compared to the northern part of the cross section.
96 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater seismic profile to be, at least in part, equivalent to the Ochopee Fish, J.E., and Stewart Mark, 1991, Hydrogeology of the surfi-Limestone Member of the Tamiami Formation. Chronostratig- cial aquifer system, Dade County, Florida: U.S. Geological raphy by Guertin (1998) indicated that on Stock Island in the Survey Water-Resources Investigations Report 90-4108, Florida Keys, the Stock Island Formation is mostly the same 50 p., 11 sheets.
age as the Tamiami Formation. Cunningham and others (1998) delineated the Stock Island Formation as mainly equivalent to Guertin, L.A., 1998, A late Cenozoic mixed carbonate/silici-the Long Key Formation, and thus entirely or mostly restricted clastic system, south FloridaLithostratigraphy, chro-to a Pliocene age. Minor groundwater flow zones are defined nostratigraphy, and sea-level record: Miami, University of in the Stock Island Formation in these test boreholes and Miami, Ph.D. dissertation, 335 p.
provide examples of minor aquifer zones within the interme-diate confining unit. It is likely that the Stock Island Formation Reese, R.S., and Cunningham, K.J., 2000, Hydrogeol-is a low permeability, relatively deeper-water, outer-ramp ogy of the gray limestone aquifer in southern Florida:
equivalent to units within the Tamiami Formation that are U.S. Geological Survey Water-Resources Investigations much better defined to the west (Reese and Cunningham, Report 99-4213, 244 p.
2000). New continuously drilled cores that span the complete thickness of the Biscayne aquifer, advanced geophysical logs, and new seismic profiles in canals and offshore in Biscayne Bay and the Atlantic Ocean (e.g., Cunningham and Appendix 10. Geochemical Sampling Wacker, 2009) are providing the information necessary to reinterpret the hydrogeologic setting described by Causaras Methods (1987) and Fish and Stewart (1991).
A total of 52 groundwater samples were collected from 34 wells, and 17 surface-water samples were collected from Core Descriptions 10 surface-water monitoring sites by using a submersible pump, centrifugal suction pump, or Kemmerer water sampler.
Core descriptions from the eight new wells installed The sampling method used to collect each sample is provided during the study are provided in a supplementary Adobe in table 2-1. Site selection and sampling method were based Acrobat TM Portable Document Format file. General informa- on type of site (surface water or groundwater), well construc-tion concerning site location, core-hole depth, and available tion, well installation date, location, and the purpose of each borehole geophysical logs is provided for each of the cores sample. Sites were selected on both sides of the leading edge described. The depths to the top of the Miami Limestone, the of the saltwater front. Wells near canals and farther away from Fort Thompson Formation, and the Tamiami Formation are canals were selected for comparison purposes.
included in this general information. Wells with short open intervals situated near the base of the aquifer are able to provide the most reliable information See supplemental file http://pubs.usgs.gov/sir/2014/5025/ concerning the inland extent and age of saltwater in the appendix/sir2014-5025_appendix_09.pdf. aquifer. In some areas, however, the only available monitoring wells have long open intervals. In long open-interval wells, water of different ages and chemical compositions potentially could mix, which could greatly reduce the value of samples References collected for age dating and evaluation of maximum salinity in the aquifer.
Sampling and decontamination procedures generally Causaras, C.R., 1987, Geology of the surficial aquifer system, adhered to those described in the USGS National Field Dade County, Florida: U.S. Geological Survey Water-Manual for the collection of water-quality data (U.S. Geolog-Resources Investigations Report 86-4126, 240 p., 2 sheets.
ical Survey, variously dated), but procedures documented on Cunningham, K.J., McNeill, D.F., Guertin, L.A., Ciesielski, the websites of the USGS Chlorofluorocarbon Laboratory in P.F., Scott, T.M., and de Verteuil, L., 1998, New Tertiary Reston, Virginia (U.S. Geological Survey, 2011a, b, c), and stratigraphy for the Florida Keys and southern peninsula methods similar to those described by Kohout and Hoy (1963) of Florida: Geological Society of America Bulletin, v. 110, also were used.
no. 2, p. 231-258. A Fultz TM SP-400 submersible pump with 100% Teflon lines was used to collect groundwater samples. Each sample Cunningham, K.J., and Wacker, C., 2009, Seismic-sag collected using this pump was processed in a chamber that structural systems in Tertiary carbonate rocks beneath consisted of a clear, virgin, poly-resin, disposable bag. The southeastern Florida, USAEvidence for hypogenic bag prevented contamination by dust and cross-contamination speleogenesis? in Klimchouk, A.B., and Ford, D.C., between samples. Temperature, pH, dissolved oxygen, and eds., Hypogene speleogenesis and karst hydrogeology specific conductance were monitored with a calibrated YSI of artesian basins: Simferopol, Ukraine, Ukrainian Insti- Professional PlusTM multimeter and a flow-through chamber.
tute of Speleology and Karstology, Special Paper no. 1, Turbidity samples were periodically collected during
- p. 151-158. purging by using a HachTM 2100P portable turbidity meter.
Appendixes97 Hydrogen sulfide was evaluated with a Hach HS-WR 0- to Sample Analysis and Quality Assurance 11.25-mg/L test kit at selected sites. Samples collected by using the submersible pump were evaluated to determine the Major and trace ion analyses were conducted at the concentrations of the full suite of analytes, including barium, USGS National Water Quality Laboratory in Denver, boron, bromide, calcium, chloride, fluoride, iron, magnesium, Colorado, by using the methods described in Clesceri and potassium, silica, sodium, strontium, sulfate, tritium, uranium, others (1998), Fishman and Friedman (1989), Fishman (1993),
tritium (3H), alkalinity, pH, temperature, specific conductance, Garbarino (1999), and Garbarino and others (2006). The turbidity, dissolved oxygen, and the isotopic ratios of tritium concentrations in water samples (table 2-3) were eval-18 O/16O and 2H/1H. Selected sites were sampled to evaluate uated by the USGS Stable Isotope and Tritium (USGS-SI&T)
(1) the age of the water by using 3H/3He and SF6 age-dating Laboratory in Menlo Park, California, by using electrolytic methods, (2) the isotopic ratio of 87Sr/86Sr, (3) dissolved gas enrichment and liquid scintillation. The 87Sr/86Sr isotope ratios composition, and (4) terrigenic helium concentration. were analyzed by the USGS Metal and Metalloid Isotope A small, 4-stroke, variable-speed, gasoline-powered Laboratory in Menlo Park, California, as described in Katz HondaTM WX10 centrifugal suction pump was used to sample and Bullen (1996). Alkalinity was analyzed by titration with a surface-water sites. The centrifugal pump could pump at rates Hach Universal Digital Titrator and 1.600 +/- 0.008 N sulfuric up to 60 L/min, but could not pump at rates as slow as the acid by using the inflection point method. Titrations were Fultz submersible pump. The speed of the centrifugal pump usually performed twice for each sample, and the average was too great to allow the use of the flow-through chamber, alkalinity and bicarbonate concentrations were computed.
so probes from either the YSITM Professional Plus multimeter or an OaktonTM pH/Con 10 series multimeter were placed in Alkalinity, terrigenic helium, and dissolved gas samples were a bucket receiving discharge from the pump. The flow rate kept refrigerated until analyzed.
of the suction pump was more than sufficient to exchange Dissolved gas composition (table 2-2) and SF6 water in the bucket as rapidly as the submersible pump had concentrations (table 2-4) were analyzed by the USGS exchanged water in the flow-through cell. Dissolved oxygen Chlorofluorocarbon laboratory in Reston, Virginia, following was not measured. The centrifugal pump was decontaminated the procedures described in USGS (2011d, i). The USGS between samples by using the same procedures that were used Chlorofluorocarbon laboratory also evaluated the terrigenic on the submersible pump. To facilitate sampling, a valve was helium in water samples with a Hewlett Packard 5890 Series installed in the discharge line, which allowed a part of the gas chromatograph. The isotope compositions of oxygen and pump discharge to be diverted to a small-diameter sampling hydrogen expressed in terms of 18O and 2H (table 2-7) were line to which a filter could be attached. The centrifugal pump determined by the USGS-SI&T as described in Révész and was only used to collect samples for the evaluation of major Coplen (2008a, b).
ion and tritium concentrations and the stable isotope ratios 3 H/3He age dating was performed by the Lamont-Doherty of oxygen and deuterium. These parameters were deemed Earth Observatory Noble Gas laboratory at the Earth Institute at sufficiently stable for sampling by using this method. Columbia University (CU-LDEO) in Palisades, New York. The The long open-interval wells FKS4, FKS7, and FKS8 CULDEO laboratory determined the concentration of tritium by (appendix 1) were sampled with a Kemmerer water sampler. helium ingrowth. They also determined the concentrations of A flow-through cell could not be used with the Kemmerer. helium and neon and the isotope ratios of 3He/4He. Additional Instead, once the Kemmerer was retrieved from the well, a information concerning the methods used for mass spectrom-small part of the sample was placed in a cup that held the etry of helium isotopes and for measurement of the tritium probes of the multimeter for evaluation of pH, temperature, concentration in water samples by the 3He ingrowth method is and specific conductance. Measurements of these parameters in provided by Ludin and others (1997). Ages were determined by samples collected in this manner may not be fully representa- using the relation of Schlosser and others (1988):
tive of aquifer conditions because of the changes in pressure and temperature that can occur during measurement. The Kemmerer could only be used to collect samples for analysis of T1/ 2 3 Hetrit major ion and tritium concentrations and oxygen and deuterium t= ln 1 + 3 , (10-1) ln 2 H stable isotope ratios because of the small sample volume and because the sample comes into contact with the air when released from the Kemmerer. It should be noted that sampling where t is the 3H/3He age in years, 3Hetrit is the concentration with a Kemmerer does not avoid the problem of mixing as a of tritiogenic helium, T1/2 is the half-life of tritium, and result of ambient vertical flow in the borehole. Site set-up and 3
H is the concentration of tritium. The amount of 3Hetrit cleaning procedures used for Kemmerer sampling were similar derived from radioactive decay of 3H in the water sample is to those used for samples collected with the submersible pump. determined by using a helium isotope mass balance (Schlosser Dissolved gas samples (table 2-2) generally were not and others, 1988). The helium concentration of groundwater collected at surface-water sampling sites because they are can be enriched by terrigenic helium, which can interfere in used to evaluate the temperature of the water at the time that the mass balance used to compute amount of 3Hetrit derived it entered the aquifer. These samples were only collected at from radioactive decay. The neon concentration of the water selected sites. sample, which is assumed to be derived solely from the
98 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater atmosphere, is used to calculate the amount of additional samples from G-3600 were negative, which indicates that 3
Hetrit (Schlosser and others, 1989). To determine if the gas fractionation has occurred and that the age of this sample terrigenic helium concentration in samples is excessive, the is questionable. Analyses of samples collected from wells concentrations of helium, hydrogen, and neon in samples G-3608, G-896, and G-894 and the C2 Canal at G-3608 were determined by the USGS Reston Chlorofluorocarbon indicated respective 4He/Ne ratios of 0.7, 0.7, 0.8, and Laboratory (USGS-RCL) using gas-chromatography, and 0.5. These results indicate that gas fractionation may have the concentration of helium that is in excess of the air-water occurred. Gas fractionation of canal water seems reasonable equilibrium (4He) was computed using the relation given that the canal water is always in contact with the atmo-sphere. The samples from wells G-896 and G-3608, which are 0.38 km and 8 m, respectively, from the Snapper Creek 4 Hes 4 Heeq Canal, also could be affected by gas fractionation; however, 4 He = 4 x100 , (10-2) the locations of these wells relative to the Snapper Creek Heeq Canal, the extraordinary permeability of the Biscayne aquifer, and the concordance of the samples collected in this area with where 4Hes is the helium concentration of the sample and respect to the 4He/Ne ratios indicate that the 3H/3He ages 4
Heeq is the air-water equilibrium concentration of helium. from these wells may be reliable. Samples from wells G-896 If the 4He is positive, the sample contains excess air or and G-3608 indicated interpreted piston-flow ages that date to terrigenic helium. If the tritium concentration is greater than about 1998 and 1997, respectively (table 2-5).
0.5 TU and if 4He is less than 200 percent, 3H/3He age The results of tritium analyses provided by the dating is likely to be successful. Corrections for terrigenic CU-LDEO lab (table 2-5) were used for 3H/3He age dating helium were applied to samples that indicated that terrigenic and are of greater precision than analyses provided by the helium was greater than 5 percent. If the 4He is negative USGS-SI&T laboratory (table 2-3). The analyses by the by more than a few percent, the sample may have degassed USGS-SI&T were used to ensure that tritium levels were and may not be able to be dated. The precision of analyses within the acceptable range for analysis by the CU-LDEO of the dissolved gases helium, hydrogen, and neon are lab and would not contaminate the CU-LDEO lab. Samples respectively 20, 10-20, and 10 percent (Busenberg and analyzed by the USGS-SI&T laboratory also were used to others, 2000; Eurybiades Busenberg, U.S. Geological Survey, evaluate tritium concentrations in the aquifer. The standard written commun., May 25, 2011). All but one of the samples deviation of analyses for all samples evaluated by the (well G-3609) had 4He values of less than 200 percent CU-LDEO laboratory for this study ranged from 0.04 to (table 2-6). The 4He of the samples collected from well 0.91 TU, whereas the standard deviation for analyses by the G-3609 on July 30, 2009, and December 17, 2009, were USGS-SI&T laboratory ranged from 0.4 to 1.7 TU. Analytical 8.5 and 215.3, respectively. Given this large discrepancy, the results from the CU-LDEO were used to determine analytical sample collected on December 17, 2009, may have had an ages and interpreted piston-flow ages. The analytical ages air bubble that was not identified during sampling. Excluding were determined using the analytical results of the CU-LDEO, the one sample from G-3609, the 4He ranged from 0.1 to measured salinity of the each sample, the approximate altitude 154.9 percent and averaged 36.6 percent. The 4He was not of each sample location, and the recharge average recharge negative in any of these samples; therefore, these samples temperature determined from dissolved gas analyses. A crustal potentially could be used for 3H/3He age dating. terrigenic 3He/4He ratio of 2.00 x 10-8 was used. The half-life The 3H/3He age-dating results provided by the CU-LDEO of tritium used was 12.32 years. Interpreted piston-flow ages laboratory also included determinations of 4He. The analyses were determined based on the determined ages and amount by the CU-LDEO laboratory were generally higher in preci- of tritium. Samples with very low tritium are considered to sion than those that could be obtained by the USGS-RCL provide only a very coarse understanding of age. Samples using gas chromatography. The 4He in samples determined that have analytical ages older than 1970, which is considered by the CU-LDEO laboratory ranged from 2.6 to 71.7 percent beyond the practical range of this dating method, were (table 2-5). Terrigenic helium corrections were applied to assigned interpreted piston-flow ages of < 1970. Most inter-3 H/3He age dates of all samples that had terrigenic helium preted piston-flow ages are considered approximate, because concentrations that were greater than 5 percent. of the uncertainties in recharge temperature, gas fractionation, Excess air in samples also can potentially interfere with and the 3He/4He ratio.
3 H/3He age-dating analyses. Samples for which the Ne and A 3H/3He age-dating sample was collected from only one 4He/Ne ratios are negative indicate that gas fractionation surface-water site because surface water typically is consid-occurred. Where the 4He/Ne ratio is less than 1, it is also ered to be in relatively close equilibrium with the atmosphere possible that some gas fractionation may have occurred. and therefore would have an age near zero. The surface-water When water comes in contact with air, the helium tends to sample was collected to determine if older groundwater was diffuse more rapidly into the air than neon. If gas fractionation flowing into the canal in sufficient quantities to be detected.
removed parent or daughter products from the system, it 3 H/3He age-dating samples were not collected from long could invalidate the determined age. The Ne and 4He/Ne screened wells or from newly installed wells where the mixing ratios were computed for samples analyzed by the CU-LDEO of water caused by sampling or well installation would affect laboratory (table 2-5). The Ne and 4He/Ne ratios in the ages determined.
Appendixes99 Quality-Assurance Samples was lost. The absolute value of the difference between the analytical results of each pair of original and replicate Replicate samples consisted of two or more sets of samples was divided by the arithmetic mean of these results to samples collected concurrently so that both samples are determine percent differences (table 2-2). Replicate estimates assumed to have identical water chemistry. Three replicate of recharge temperature differed by only 0.80 percent, samples of major and trace ions were collected (table 2-1). on average, with a maximum difference of 1.91 percent.
The average difference between analytical results of original Replicate samples of methane and oxygen differed by as much and replicate samples of major and trace ions was +/-1.9 percent as 53.3 and 46.1 percent, respectively, and differences may when all constituents were considered. The largest differences have been caused by bacterial consumption of oxygen. The were observed for the analyses of fluoride and uranium. The determinations of recharge temperature were likely unaf-difference between fluoride concentrations in original and fected because the two samples which indicated the largest replicate samples was +/-7.5 percent. The replicate sample from differences in methane and oxygen (C2 Canal at G-3608 well G-3610 indicated a -19.6 percent difference in uranium and well G-3607) indicated small differences in the recharge concentration from the original sample. The concentrations temperatures (1.39 and 0.19 percent, respectively).
of fluoride and uranium were low in the replicate and original Replicate samples were collected for all samples of samples for which large percentage differences were evalu- oxygen and hydrogen stable isotopes. Most of the replicate ated. The fluoride concentrations of these replicate samples samples were retained as potential replacement samples in ranged from 0.13 to 0.16 mg/L, and the reporting level for this case any of the original samples were lost during shipment to analysis was 0.08 mg/L. The amounts of uranium measured the laboratory for analysis. After results were received from in the original and replicate samples from well G-3610 were the original samples, thirteen of the replicate samples were 0.021 and 0.017 µg/L, respectively, and the reporting level for selected for analysis to evaluate the precision of the analytical this analysis was 0.008 µg/L. Excluding fluoride and uranium, method and the sampling procedures. The absolute value the analytical results of major and trace ions in original and of differences between the original and replicate samples replicate samples differed by +/-4.4 percent. analyzed for 2H ranged from 0.54 to 126 percent and aver-All of the samples collected to evaluate SF6, dissolved aged 26.0 percent. The absolute value of differences between gases, and 3H/3He age dating were collected in replicate. the original and replicate samples analyzed for 18O ranged Analytic results of the original and replicate samples of from 1.32 to 106 percent and averaged 18.9 percent. Although dissolved gases and SF6 are reported (tables 2-2 and 2-4), these differences seem large, when evaluted graphically except when a sample was lost or damaged during transport. (fig. 10-1) they do not greatly alter the interpretations that Replicates were collected for all dissolved gas samples, can be drawn from the analyses. For example, even though with the exception that the replicate sample from G-894 the differences between the original and replicate analyses of 4
C2 Canal 150 feet upstream of S-22, 9/14/2010 C2 Canal at G-3608, 9/15/2010 2
C2 Canal at G-3608, 7/28/2009 0 G-3608, 7/27/2009 G-3608, 9/15/2010 C2 Canal 150 feet Delta deuterium, per mil
-2 G-896, 09/21/2010 upstream of S-22, 08/3/2009 G-896, 08/04/2009
-4 G-3855, 8/18/2009 G-3607, 7/17/2009 G-3856, 8/18/2009
-6 G-1264, 10/27/2010
-8 EXPLANATION
-10 Original sample results G-3609, 7/30/2009 Replicate sample results
-12
-2.5 -2.0 -1.5 -1.0 -0.5 0 0.5 Delta oxygen-18, per mil Figure 10-1. Delta oxygen-18 and delta deuterium for samples and replicate samples, 2009-2010, Miami-Dade County, Florida.
100 Origins and Delineation of Saltwater Intrusion in the Biscayne Aquifer and Changes in the Distribution of Saltwater 2H and 18O in well G-3608 collected on July 27, 2009, were Fishman, M.J., ed., 1993, Methods of analysis by the U.S.
126 and 23.0 percent, respectively, the results still plot within Geological Survey National Water Quality Laboratory a small area as shown by the blue circles around each original Determination of inorganic and organic constituents in and replicate sample in figure 10-1. water and fluvial sediments: U.S. Geological Survey Open-To ensure that the deionized water used for equipment File Report 93-125, 217 p.
cleaning did not contain the major and trace ions evaluated during the study, quality-assurance samples of deionized Fishman, M.J., and Friedman, L.C., 1989, Methods for water were collected directly from the filtration system on determination of inorganic substances in water and fluvial July 16, 2009, and December 15, 2009, and analyzed for sediments: U.S. Geological Survey Techniques of Water-all ions of interest. No detections of any major or trace Resources Investigations, book 5, chap. A1, 545 p.
ions were above the minimum reporting levels for any of Garbarino, J.R., 1999, Methods of analysis by the U.S.
these ions. Geological Survey National Water Quality Laboratory To ensure that the equipment was properly Determination of dissolved arsenic, boron, lithium, sele-decontaminated between samples, 11 equipment blanks were nium, strontium, thallium, and vanadium using inductively collected using deionized water from the USGS National coupled plasma-mass spectrometry: U.S. Geological Survey Water Quality Laboratory. Minor amounts of iron ranging Open-File Report 99-093, 31 p.
from an estimated 2.3 to 8 µg/L were detected in 6 of the 11 equipment blanks, but because many of the well casings Garbarino, J.R., Kanagy, L.K., and Cree, M.E., 2006, Determi-were constructed of iron and the pump head was constructed nation of elements in natural-water, biota, sediment, and soil of stainless steel, this analyte was not considered for evalua- samples using collision/reaction cell inductively coupled tion of aquifer geochemistry. Excluding iron, one or more of plasma-mass spectrometry: U.S. Geological Survey Tech-the analytes evaluated for this study were detected in 4 of the niques and Methods, book 5, sec. B, chap. 1, 88 p.
11 blanks. The majority of these detections were below or very Katz, B.G., and Bullen, T.D., 1996, The combined use of close to the normal reporting level for the analytes detected.
87Sr/86Sr and carbon and water isotopes to study the Although calcium, chloride, magnesium, sodium, and hydrochemical interaction between groundwater and lake-strontium were detected in equipment blanks, the detections water in mantled karst: Geochimica et Cosmochimica Acta, were only 0.2 to 2.1 percent of the minimum concentrations
- v. 60, no. 24, p. 5075-5087.
measured in the groundwater and surface-water samples that were collected, and as such would not significantly affect Kohout, F.A., and Hoy, N.D., 1963, Some aspects of sampling the results of analyses. The one exception was the detection salty ground water in coastal aquifers: Ground Water, v. 1, of 22.8 µg/L of boron in the equipment blank collected at no. 1, p. 28-32.
C-5 Canal at NW 32 Court on August 6, 2010. The amount of boron in all other equipment blanks was less than the Ludin, A.I., Weppernig, Ralf, Bonisch, G., and Schlosser, reporting level of 4 µg/L. The boron concentrations in samples Peter, 1997, Mass spectrometric measurement of helium ranged from 27.2 to 2,470 µg/L. Boron averaged 245 µg/L in isotopes and tritium in water samples: Lamont-Doherty groundwater samples and 42.4 µg/L in surface-water samples. Earth Observatory of Columbia University, Technical Report 98.6, accessed May 12, 2011, at http://www.ldeo.
columbia.edu/~etg/ms_ms/Ludin_et_al_MS_Paper.html.
References Révész, Kinga, and Coplen, T.B., 2008a, Determination of the (2H/1H) of water: RSIL lab code 1574, chap. C1 of Révész, Kinga, and Coplen, T.B., eds., Methods of the Busenberg, Eurybiades, Plummer, L.N., Doughten, M.W.,
Reston Stable Isotope Laboratory: U.S. Geological Survey Widman, P.K., and Bartholomay, R.C., 2000, Chemical Techniques and Methods 10-C1, 27 p.
and isotopic composition and gas concentrations of ground water and surface water from selected sites at and near the Révész, Kinga, and Coplen, T.B., 2008b, Determination of Idaho National Engineering and Environmental Labora- the (180/160) of water: RSIL lab code 489, chap. C2 of tory, Idaho, 1994-97: U.S. Geological Survey Open-File Révész, Kinga, and Coplen, T.B., eds., Methods of the Report 00-81, 51 p. Reston Stable Isotope Laboratory: U.S. Geological Survey Techniques and Methods, 10-C2, 28 p.
Clesceri, L.S., Greenburg, A.E., and Eaton, A.D., eds., 1998, Standard methods for the examination of water and waste- Schlosser, Peter, Stute, Martin, Dorr, Helmut, Sonntag, water (20th ed.): Washington, D.C., American Public Health Christian, and Munnich, K.O., 1988, Tritium/3He dating of Association, American Water Works Association, and Water shallow groundwater: Earth and Planetary Science Letters, Environment Federation, p. 3-37 to 3-43. v. 89, p. 353-362.
Appendixes101 Schlosser, Peter, Stute, Martin, Sonntag, Christian, and Mun-nich, K.O., 1989, Tritiogenic 3He in shallow groundwater:
Appendix 11. Salinity Measurements Earth and Planetary Science Letters, v. 94, p. 245-256. in Canals U.S. Geological Survey, variously dated, National field man- Monthly measurements of salinity in canals collected ual for the collection of water-quality data: U.S. Geologi- by the Miami-Dade County Permitting, Environmental, cal Survey Techniques of Water-Resources Investigations, and Regulatory Affairs (M-D PERA); Maria Idia Macfar-book 9, chaps. A1-A9, available online at http://pubs.water. lane, Water and Sewer Department, written commun.,
usgs.gov/twri9A. March 7, 2011; Craig Grossenbacher, Miami-Dade County Permitting, Environmental, and Regulatory Affairs, written U.S. Geological Survey, 2011a, Reston Chlorofluorocar- commun., July 7, 2010) are provided as supplemental files.
bon LaboratorySF6 sampling: U.S. Geological Survey, accessed April 29, 2011, at http://water.usgs.gov/lab/sf6/ See supplemental file http://pubs.usgs.gov/sir/2014/5025/
sampling/. appendix/sir2014-5025_appendix_11.xlsx.
U.S. Geological Survey, 2011b, Reston Chlorofluorocarbon Laboratory Dissolved Gas N2 / Ar and 4He Sampling:
U.S. Geological Survey, accessed June 25, 2013, at http:// Appendix 12. Geographic Information water.usgs.gov/lab/dissolved-gas/sampling/.
System Files U.S. Geological Survey, 2011c, Reston Chlorofluorocarbon Laboratory3H/3He sampling: U.S. Geological Survey, GIS files for the 2008 and 2011 lines showing the inland accessed April 26, 2011, at http://water.usgs.gov/lab/3h3he/ extent of saltwater in the Biscayne aquifer are provided as sampling/. ESRI Arc-GIS shape files in separate electronic files. Metadata are included in these files. Users should view the Federal U.S. Geological Survey, 2011d, Reston Chlorofluorocarbon Geographic Data Committee (FGDC) metadata, because LaboratoryAnalytical procedures for SF6: U.S. Geologi- it provides important distribution information that other cal Survey, accessed April 26, 2011, at http://water.usgs. metadata formats do not include. These files describe the gov/lab/sf6/lab/analytical_procedures/. conditions of usage. The column LINETYPE in the attribute table should be used to indicate where the lines are shown as U.S. Geological Survey, 2011i, Reston Chlorofluorocarbon solid or dashed. To confirm that users are depicting this line LaboratoryAnalytical procedures for dissolved gasses correctly they should compare their maps to the USGS maps N2 / Ar: U.S. Geological Survey, accessed April 26, 2011, of these lines available at: http://www.envirobase.usgs.gov/
at http://water.usgs.gov/lab/dissolved-gas/lab/analytical_ FLIMS/SaltFront/viewer.htm (U.S. Geological Survey, 2011g).
procedures/.
See supplemental files in the folder http://pubs.usgs.gov/
sir/2014/5025/appendix/sir2014-5025_appendix_12.
Manuscript approved February 17, 2014 Prepared by the Raleigh Publishing Service Center Kimberly Waltenbaugh, Editor Kimberly Swidarski, Illustrations and layout For more information about this publication, contact:
Director U.S. Geological Survey Florida Water Science Center 4446 Pet Lane, Suite 108 Lutz, FL 33559 (813) 498-5000 or visit our website at http://fl.water.usgs.gov
Prinos and othersOrigins and Delineation of Saltwater Intrusion in the Biscayne AquiferScientific Investigations Report 2014-5025 ISSN 2328-0328 (online) http://dx.doi.org/10.3133/sir20145025