Florida Power & Light Company Biological Plan of Study Implementation for St. Lucie Plant EPU Baseline Event 4 Data Report Report to Florida Power & Light Company May 2012 Submitted by Ecological Associates, Inc.

Post Office Box 405 Jensen Beach, Florida

ECOLOGICAL ASSOCIATES, INC., JENSEN BEACH, FLORIDA INTRODUCTION During February and March 2012, Ecological Associates, Inc. (EAI) conducted the fourth baseline field sampling event in accordance with the St. Lucie Plant EPU Biological Plan of Study. During this fourth event, sampling was conducted on seven days between February 15 and March 1, 2012. Data collected included general environmental data; water quality data; numbers and sizes of fish and shellfish collected by gill net, trawl, and beach seine; numbers of fish eggs and larvae and commercially or recreationally important decapod crustacean larvae collected by plankton net; and, numbers and sizes of sea turtles observed. Results of the fourth sampling event are provided in this report. All data should be considered preliminary until quality assurance checks have been completed.

SAMPLING LOCATIONS Sampling was conducted within three separate sampling sites: SL1 located midway between the St. Lucie Plant and the Ft. Pierce Inlet, SL2 located in the vicinity of the St. Lucie Plant cooling water discharge, and SL3 located midway between the St. Lucie Plant and the St. Lucie Inlet.

For the purposes of gill netting and trawling, three transects were established within each of the three sampling sites: Transect A was located approximately 600 ft from shore on the beach terrace in water depths of 8-32 ft, Transect B was located approximately 4,000 ft. from shore in water depths of 34-44 ft, and Transect C was located approximately 8,000 ft. from shore in water depths of 31-46 ft. Plankton samples were collected concurrently with trawl samples at all three sites but only on Transects A and C.

Three stations were also established within each of the three sampling sites for the purpose of beach seining: Station A was located 0.5 mi. north of the center of the site, Station B was located at the center of the site, and Station C was located 0.5 mi. south of the center of the site.

At all stations, seines were pulled to the beach from a water depth of approximately 4 ft.

For the purpose of boat-based sea turtle surveys, one transect was established in each of the three sampling sites. The transects were located along nearshore hardbottom habitat in each site.

RESULTS Environmental data were recorded at each station during each day of sampling. Data recorded included sea conditions, air temperature, wind speed and direction, and sky conditions.

Environmental data are summarized by day in Table 1. Values reflect the range of values recorded throughout each day of sampling.

Water quality data were recorded at three locations and three depths along each of the nine transects established for trawl and gill net sampling. Data recorded included conductivity, water temperature, salinity, pH, and dissolved oxygen (DO). Water quality data are provided in Table

2.

BASELINE EVENT 4 DATA REPORT, ST. LUCIE PLANT EPU BIOLOGICAL STUDY ECOLOGICAL ASSOCIATES, INC., JENSEN BEACH, FLORIDA 2

Trawls were towed for 15 minutes along each of the nine transects. The numbers of fish and commercially or recreationally important shellfish collected in each 15-minute tow are presented in Table 3. Because of variations in tow speed, the distances the trawl traveled during a 15-minute tow varied (based on GPS readings). In order to compare abundances among stations in terms of catch per unit effort, the numbers collected per kilometer of bottom sampled were calculated and are presented in Table 4.

The numbers of fish and commercially or recreationally important shellfish collected by gill net on each of the nine transects is given in Table 5. At each transect the gill net began to be retrieved 30 minutes after it was set. However, the total soak time (time from when the net first entered the water until the time it was completely removed from the water) varied among transects because of differences in retrieval times associated with variations in the number of fish present in the net. In order to compare abundances among stations in terms of catch per unit effort, the numbers collected per hour of total soak time were calculated and are given in Table

6.

Beach seines were deployed at each of the nine stations previously described. The numbers of fish and commercially or recreationally important shellfish collected at each station are presented in Table 7.

A maximum of 25 representative specimens of each Representative Important Species (RIS) of fish collected at each transect/station by trawl, gill net, and beach seine were measured (total length) and a batch weight for those specimens was obtained. Average lengths and average weights of each RIS at each station/transect for each gear type are presented in Table 8.

Bongo nets were used to collect fish eggs and larvae as well as commercially or recreationally important decapod crustacean larvae at each of the six transects previously described. Nets were pulled for 15 minutes and the volume of water filtered determined by means of flow meters.

Numbers of individuals per cubic meter of water filtered are given in Table 9.

To quantify the number of sea turtles present in each of the three sampling sites, one one-kilometer-long transect in each sampling site was traversed by boat twice. The numbers of sea turtles sighted during each pass along each transect are presented in Table 10.

Table 1. Environmental Data, Baseline Sampling Event 4 (February - March 2012), St. Lucie Plant EPU Biological Study. Values reflect the range of values recorded throughout each day of sampling.

Sampling Date Sea Conditions Air Temp Wind Speed/Direction Sky Conditions Trawls/

Ichthyoplankton 2/23/2012 Calm to 2-3 ft swell 21.5-28.5°C 3-10 mph/SE to WSW Clear Trawls/

Ichthyoplankton 2/24/2012 1-4 ft swell 21.0-27.0°C 3-15 mph/SW to W Clear Gill Nets 2/15/2012 1-3 ft swell 21.3-26.7°C 5-10 mph/S to SE Clear to Partly Cloudy Gill Nets 2/16/2012 2-3 ft swell 21.4-22.8°C 5-10 mph/S to SE Mostly Cloudy Gill Nets 2/17/2012 calm 23.4°C 0-3 mph/S Partly Cloudy Beach Seines 3/1/2012 1-3 ft swell 21.7-32.1°C 0-7 mph/S Clear to Mostly Cloudy Sea Turtle Transects 2/24/2012 2 ft swell, slight chop 24.4°C 5-7 mph/SW to SSW Partly Cloudy

Table 2. Water Quality Data, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. NR = not recorded Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Trawl SL1 A North Surface 55.60 22.87 36.75 8.20 6.53 Mid-Depth 55.50 22.92 36.75 8.20 6.50 Bottom 55.60 22.92 36.68 8.20 6.43 Middle Surface 55.50 23.01 36.68 8.18 6.65 Mid-Depth 56.60 23.01 36.76 8.19 6.50 Bottom 55.50 23.00 36.76 8.19 6.55 South Surface 55.50 23.13 36.76 8.18 6.90 Mid-Depth 55.60 23.15 36.76 8.18 6.79 Bottom 55.50 23.15 36.69 8.19 6.68 Trawl SL1 B North Surface 55.50 23.31 36.77 8.21 6.46 Mid-Depth 55.50 23.32 36.77 8.21 6.56 Bottom 55.50 23.32 36.70 8.21 6.51 Middle Surface 55.70 23.31 36.85 8.20 6.48 Mid-Depth 55.50 23.33 36.70 8.20 6.58 Bottom 55.50 23.32 36.70 8.20 6.48 South Surface 55.60 23.36 36.78 8.17 6.57 Mid-Depth 55.50 23.36 36.77 8.18 6.57 Bottom 55.50 23.32 36.77 8.19 6.49 Trawl SL1 C North Surface 55.60 23.34 36.78 8.17 6.67 Mid-Depth 55.60 23.34 36.78 8.19 6.62 Bottom 55.50 23.35 36.70 8.20 6.54 Middle Surface 55.60 23.24 36.77 8.21 6.54 Mid-Depth 55.60 23.31 36.77 8.21 6.57 Bottom 55.50 23.32 36.77 8.21 6.51 South Surface 55.60 23.24 36.77 8.21 6.66 Mid-Depth 55.60 23.24 36.77 8.21 6.61 Bottom 55.50 23.30 36.70 8.22 6.62 Trawl SL2 A North Surface 55.60 23.50 36.78 8.16 6.56 Mid-Depth 55.60 23.44 36.78 8.18 6.57 Bottom 55.50 23.35 36.70 8.19 6.47 Middle Surface 55.60 23.58 36.71 8.20 6.42 Mid-Depth 55.50 23.33 36.70 8.20 6.53 Bottom 55.60 23.18 36.69 8.21 6.43 South Surface 55.50 23.73 36.72 8.21 6.52 Mid-Depth 55.50 23.24 36.77 8.21 6.43 Bottom 55.60 23.19 36.69 8.21 6.48

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Trawl SL2 B North Surface 55.60 23.30 36.77 8.21 6.67 Mid-Depth 55.60 23.32 36.77 8.22 6.70 Bottom 55.60 23.31 36.77 8.22 6.59 Middle Surface 55.60 23.16 36.76 8.22 6.56 Mid-Depth 55.60 23.18 36.69 8.22 6.49 Bottom 55.70 23.16 36.69 8.22 6.74 South Surface 55.60 23.06 36.76 8.23 6.63 Mid-Depth 55.60 23.10 36.76 8.22 6.64 Bottom 55.60 23.09 36.69 8.23 6.89 Trawl SL2 C North Surface 55.60 23.29 36.77 8.21 6.62 Mid-Depth 55.60 23.31 36.77 8.22 6.57 Bottom 55.50 23.31 36.70 8.22 6.51 Middle Surface 55.70 23.18 36.84 8.23 6.67 Mid-Depth 55.70 23.18 36.77 8.23 6.71 Bottom 55.60 23.23 36.77 8.23 6.58 South Surface 55.60 23.21 36.84 8.23 6.46 Mid-Depth 55.60 23.23 36.77 8.23 6.68 Bottom 55.50 23.22 36.77 8.23 6.63 Trawl SL3 A North Surface 55.70 23.39 36.85 8.22 6.37 Mid-Depth 55.70 23.39 36.85 8.22 6.50 Bottom 55.70 23.40 36.85 8.22 6.45 Middle Surface 55.70 23.39 36.85 8.20 6.40 Mid-Depth 55.70 23.41 36.85 8.21 6.51 Bottom 55.70 23.41 36.85 8.21 6.57 South Surface 55.70 23.40 36.85 8.18 6.63 Mid-Depth 55.70 23.40 36.78 8.19 6.57 Bottom 55.70 23.43 36.85 8.19 6.50 Trawl SL3 B North Surface 55.70 23.47 36.86 8.19 6.50 Mid-Depth 55.70 23.47 36.86 8.20 6.44 Bottom 55.60 23.46 36.78 8.20 6.45 Middle Surface 55.70 23.48 36.86 8.21 6.49 Mid-Depth 55.60 23.49 36.78 8.21 6.47 Bottom 55.60 23.49 36.78 8.21 6.39 South Surface 55.70 23.55 36.86 8.21 6.49 Mid-Depth 55.60 23.59 36.79 8.22 6.49 Bottom 55.60 23.59 36.79 8.21 6.43

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Trawl SL3 C North Surface 55.80 23.34 36.92 8.19 6.62 Mid-Depth 55.70 23.15 36.91 8.20 6.69 Bottom 55.80 22.54 36.96 8.18 6.13 Middle Surface 55.80 23.34 37.00 8.22 6.41 Mid-Depth 55.70 23.20 36.84 8.22 6.56 Bottom 55.90 22.31 36.87 8.19 5.95 South Surface 55.90 23.25 36.99 8.23 6.58 Mid-Depth 55.70 23.21 36.84 8.23 6.55 Bottom 55.80 22.65 36.89 8.21 6.03 Gill Net SL1 A West Surface 54.80 20.24 35.99 8.11 7.32 Mid-Depth 54.90 20.16 36.06 8.12 7.12 Bottom 54.90 20.10 36.06 8.13 6.98 Middle Surface 54.80 20.32 36.00 7.99 7.92 Mid-Depth 54.90 20.15 36.06 8.04 6.98 Bottom 55.00 20.08 36.06 8.06 6.97 East Surface 54.80 20.36 36.00 8.09 7.37 Mid-Depth 54.90 20.17 36.06 8.09 6.99 Bottom 55.00 20.11 36.13 8.10 6.97 Gill Net SL1 B West Surface 54.80 20.66 36.10 8.09 7.44 Mid-Depth 54.80 20.54 36.01 8.13 6.75 Bottom 54.80 20.53 36.01 8.13 6.67 Middle Surface 55.00 20.81 36.10 8.14 7.02 Mid-Depth 54.90 20.60 36.09 8.15 6.80 Bottom 54.80 20.58 36.01 8.15 6.75 East Surface 54.80 20.74 36.02 8.16 6.89 Mid-Depth 54.90 20.63 36.09 8.16 6.80 Bottom 54.80 20.60 36.02 8.16 6.73 Gill Net SL1 C West Surface 54.70 22.03 36.08 8.16 7.01 Mid-Depth 55.00 21.03 36.12 8.17 6.91 Bottom 54.90 20.98 36.11 8.18 6.89 Middle Surface 54.80 21.80 36.17 8.19 6.83 Mid-Depth 54.90 21.06 36.12 8.19 6.87 Bottom 54.90 21.01 36.11 8.19 6.84 East Surface 54.70 21.68 36.01 8.19 6.74 Mid-Depth 54.90 21.09 36.12 8.19 6.76 Bottom 55.00 21.04 36.12 8.19 6.79

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Gill Net SL2 A West Surface 54.50 22.40 35.90 8.10 7.07 Mid-Depth 54.60 21.63 35.85 8.13 7.00 Bottom 54.60 21.22 35.90 8.13 7.04 Middle Surface 54.60 22.33 35.90 8.14 6.75 Mid-Depth 54.60 21.67 35.93 8.15 6.84 Bottom 54.70 21.08 35.90 8.16 6.90 East Surface 54.50 22.55 35.91 8.16 6.72 Mid-Depth 54.60 21.58 35.93 8.17 6.76 Bottom 54.60 21.36 35.91 8.17 6.79 Gill Net SL2 B West Surface 54.50 23.17 35.95 7.98 7.06 Mid-Depth 54.60 21.89 35.95 8.07 6.91 Bottom 54.70 21.22 35.91 8.08 6.79 Middle Surface 54.40 23.28 35.95 8.12 6.63 Mid-Depth 54.60 21.37 35.95 8.12 6.72 Bottom 54.70 21.32 35.99 8.12 6.60 East Surface 54.50 23.33 35.95 8.14 6.50 Mid-Depth 54.60 21.91 35.95 8.14 6.65 Bottom 54.70 21.48 35.92 8.14 6.63 Gill Net SL2 C West Surface 54.70 23.19 36.10 8.15 6.78 Mid-Depth 54.60 22.57 35.91 8.17 6.81 Bottom 54.60 21.94 35.96 8.17 6.78 Middle Surface 54.50 23.22 35.95 8.18 6.66 Mid-Depth 54.50 22.64 35.92 8.19 6.64 Bottom 54.60 22.26 35.98 8.19 6.66 East Surface 54.50 23.25 35.88 8.19 6.57 Mid-Depth 54.50 22.56 35.99 8.19 6.63 Bottom 54.60 22.18 35.96 8.19 6.66 Gill Net SL3 A West Surface 54.10 22.60 35.60 7.77 6.33 Mid-Depth 54.00 22.40 35.50 7.75 6.33 Bottom 54.00 22.40 35.50 7.74 6.26 Middle Surface 54.10 22.70 35.60 7.81 6.52 Mid-Depth 54.10 22.50 35.50 7.81 6.47 Bottom 54.10 22.40 35.60 7.79 6.55 East Surface 54.10 22.60 35.60 7.82 6.61 Mid-Depth 54.30 22.70 35.80 7.81 6.49 Bottom 54.10 22.30 35.60 7.81 6.65

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Gill Net SL3 B West Surface 54.20 22.80 35.70 7.80 6.33 Mid-Depth 54.20 22.80 35.70 7.80 6.17 Bottom 54.50 22.80 35.90 7.77 6.26 Middle Surface 54.20 22.70 35.70 7.81 6.52 Mid-Depth 54.20 22.90 35.70 7.81 6.42 Bottom 54.50 22.60 35.80 7.79 6.37 East Surface 54.20 22.80 35.70 7.81 6.71 Mid-Depth 54.10 22.80 35.70 7.81 6.71 Bottom 54.50 23.00 35.90 7.80 6.53 Gill Net SL3 C West Surface 54.40 22.93 35.86 7.80 6.22 Mid-Depth 54.40 22.94 35.78 7.81 6.22 Bottom 54.70 22.57 35.99 7.80 6.11 Middle Surface 54.30 22.95 35.79 7.82 6.43 Mid-Depth 54.30 22.93 35.78 7.81 6.42 Bottom 54.70 22.53 36.06 7.80 6.29 East Surface 54.30 22.96 35.79 7.81 6.50 Mid-Depth 54.30 22.93 35.78 7.81 6.48 Bottom 54.60 22.54 36.06 7.79 6.39

Table 3. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Trawl during One 15-minute Tow at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study.

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Callinectes ornatus (shelligs) 2 2

Farfantepenaeus aztecus (brown shrimp) 3 3

Farfantepenaeus duorarum (pink shrimp) 2 1

3 Penaeidae sp. (penaeid shrimp) 3 3

Rimapenaeus sp.

1 2

3 1

5 12 Anisotremus surinamensis (black margate) 1 1

Centropristis striata (black sea bass) 1 1

Corvula sanctaeluciae (stripped croaker) 2 2

Cynoscion nebulosus (spotted seatrout) 1 1

Labridae sp. (wrass) 1 1

Labrisomas nuchipinnis (hairy blenny) 3 3

Lagodon rhomboides (pinfish) 1 2

3 Leiostomus xanthurus (spot) 5 3

8 Menticirrhus littoralis (Gulf kingfish) 1 1

Micropogonias undulatus (Atlantic croaker) 4 4

Ophidion holbrookii (bank cusk-eel) 1 1

Prionotus scitulus (leopard searobin) 1 1

2 Prionotus sp. (searobin) 1 1

Trachinotus carolinus (Florida pompano) 1 1

Umbrina coroides (sand drum) 3 3

TOTAL 24 5

0 19 1

1 6

0 0

56

Table 4. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured per Kilometer by Trawl at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent the number of individuals captured per kilometer for all nine transects.)

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Callinectes ornatus (shelligs) 1.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 Farfantepenaeus aztecus (brown shrimp) 0.0 0.0 0.0 2.4 0.0 0.0 0.0 0.0 0.0 0.3 Farfantepenaeus duorarum (pink shrimp) 1.7 0.0 0.0 0.8 0.0 0.0 0.0 0.0 0.0 0.3 Penaeidae sp. (penaeid shrimp) 0.0 2.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 Rimapenaeus sp.

0.9 1.5 0.0 2.4 0.7 0.0 7.8 0.0 0.0 1.2 Anisotremus surinamensis (black margate) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Centropristis striata (black sea bass) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Corvula sanctaeluciae (stripped croaker) 1.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 Cynoscion nebulosus (spotted seatrout) 0.0 0.0 0.0 0.8 0.0 0.0 0.0 0.0 0.0 0.1 Labridae sp. (wrass) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Labrisomas nuchipinnis (hairy blenny) 2.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 Lagodon rhomboides (pinfish) 0.9 0.0 0.0 1.6 0.0 0.0 0.0 0.0 0.0 0.3 Leiostomus xanthurus (spot) 4.3 0.0 0.0 2.4 0.0 0.0 0.0 0.0 0.0 0.8 Menticirrhus littoralis (gulf kingfish) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Micropogonias undulatus (Atlantic croaker) 0.0 0.0 0.0 3.2 0.0 0.0 0.0 0.0 0.0 0.4 Ophidion holbrookii (bank cusk-eel) 0.0 0.0 0.0 0.8 0.0 0.0 0.0 0.0 0.0 0.1 Prionotus scitulus (leopard searobin) 0.0 0.0 0.0 0.8 0.0 0.9 0.0 0.0 0.0 0.2 Prionotus sp. (searobin) 0.0 0.0 0.0 0.0 0.0 0.0 1.6 0.0 0.0 0.1 Trachinotus carolinus (Florida pompano) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Umbrina coroides (sand drum) 2.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 TOTAL 20.7 3.8 0.0 15.3 0.7 0.9 9.4 0.0 0.0 5.4

Table 5. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Gill Net at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study.

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Arenaeus cribrarius (speckled swimming crab) 1 1

Brevoortia smithi (yellowfin menhaden) 8 8

4 5

37 62 Caranx crysos (blue runner) 1 1

2 9

5 5

23 Caranx hippos (crevalle jack) 4 4

Carcharhinus brevipinna (spinner shark) 2 10 1

1 14 Centropristis striata (black sea bass) 1 1

Chloroscombrus chrysurus (Atlantic bumper) 9 312 75 9

405 Echeneis naucrates (sharksucker) 1 1

Leiostomus xanthurus (spot) 1 1

Lutjanus synagris (lane snapper) 2 2

Menticirrhus americanus (southern kingfish) 10 1

13 24 Menticirrhus littoralis (Gulf kingfish) 1 1

Micropogonias undulatus (Atlantic croaker) 1 14 15 Orthopristis chrysoptera (pigfish) 3 11 14 Paralichtys albigutta (Gulf flounder) 2 2

Pomatomus saltatrix (bluefish) 11 2

3 16 Rachycentron canadum (cobia) 1 1

2 Rhizoprionodon terraenovae (Atlantic sharpnose shark) 3 20 105 99 227 Scomberomorus maculatus (Spanish mackerel) 8 3

11 Selene setapinnis (Atlantic moonfish) 1 1

Sphyrna tiburo (bonnethead) 11 82 93 Synodus foetens (inshore lizardfish) 7 1

26 34 Trachinotus carolinus (Florida pompano) 1 1

TOTAL 28 55 7

11 325 35 8

377 109 955

Table 6. Catch Per Unit Effort (Number of Individuals Per Hour of Soak Time) for Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Gill Net at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent the number of individuals captured per hour for all nine transects.)

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Arenaeus cribrarius (speckled swimming crab) 1.25 0.10 Brevoortia smithi (yellowfin menhaden) 9.23 7.87 3.12 7.69 12.83 6.00 Caranx crysos (blue runner) 1.15 0.98 2.40 11.25 3.90 5.17 2.23 Caranx hippos (crevalle jack) 1.39 0.39 Carcharhinus brevipinna (spinner shark) 2.40 10.34 0.35 0.97 1.35 Centropristis striata (black sea bass) 0.78 0.10 Chloroscombrus chrysurus (Atlantic bumper) 8.85 243.12 26.01 8.71 39.19 Echeneis naucrates (sharksucker) 0.35 0.10 Leiostomus xanthurus (spot) 0.35 0.10 Lutjanus synagris (lane snapper) 3.08 0.19 Menticirrhus americanus (southern kingfish) 9.84 1.25 4.51 2.32 Menticirrhus littoralis (Gulf kingfish) 0.35 0.10 Micropogonias undulatus (Atlantic croaker) 0.98 4.86 1.45 Orthopristis chrysoptera (pigfish) 2.95 3.82 1.35 Paralichtys albigutta (Gulf flounder) 1.56 0.19 Pomatomus saltatrix (bluefish) 12.69 1.97 1.04 1.55 Rachycentron canadum (cobia) 1.54 0.35 0.19 Rhizoprionodon terraenovae (Atlantic sharpnose shark) 3.60 20.69 36.42 95.81 21.97 Scomberomorus maculatus (Spanish mackerel) 9.23 2.95 1.06 Selene setapinnis (Atlantic moonfish) 0.35 0.10 Sphyrna tiburo (bonnethead) 10.82 28.44 9.00 Synodus foetens (inshore lizardfish) 6.89 0.78 9.02 3.29 Trachinotus carolinus (Florida pompano) 0.35 0.10 TOTAL 32.31 54.10 8.40 13.75 253.25 36.21 12.31 130.75 105.48 92.42

Table 7. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Beach Seine at Each Station, Baseline Sampling Event 4 (March 2012), St. Lucie Plant EPU Biological Study.

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Arenaeus cribrarius (speckled swimming crab 1

1 Emerita sp.

2 2

Bairdiella chrysoura (silver perch) 5 1

6 Chloroscombrus chrysurus (Atlantic bumper) 1 1

Menticirrhus littoralis (Gulf kingfish) 1 1

1 3

6 Polydactylus virginicus (barbu) 1 1

Selene vomer (lookdown) 1 1

1 6

9 Trachinotus falcatus (permit) 1 1

2 Umbrina coroides (sand drum) 2 1

1 4

TOTAL 9

5 0

2 1

2 3

1 9

32

Table 8. Average total length (TL) and average weight (W) of each Representative Important Species Captured by Gill Net, Trawl, and Beach Seine, Baseline Sampling Event 4 (February-March 2012), St. Lucie Plant EPU Biological Study. For each species the number weighed/measured (n) and the total number collected (N) are given.

TAXON Gill Net Trawl Beach Seine TL (mm)

W (g) n N

TL (mm)

W (g) n N

TL (mm)

W (g) n N

Brevoortia smithi (yellowfin menhaden) 336.3 422.8 41 62 Leiostomus xanthurus (spot) 258.0 192.0 1

1 192.3 92.3 7

8 Menticirrhus americanus (southern kingfish) 351.4 467.2 23 24 Menticirrhus littoralis (Gulf kingfish) 377.0 545.0 1

1 227.0 113.0 1

1 124.9 132.1 6

6 Micropogonias undulatus (Atlantic croaker) 249.1 166.7 15 15 241.5 168.5 4

4 Orthopristis chrysoptera (pigfish) 246.1 214.4 13 14 Pomatomus saltatrix (bluefish) 405.0 632.8 16 16 Prionotus scitulus (leopard searobin) 196.5 55.4 2

2 Scomberomorus maculatus (Spanish mackerel) 459.4 500.0 11 11 Trachinotus carolinus (Florida pompano) 277.0 266.0 1

1 149.0 45.3 1

1 Umbrina coroides (sand drum) 181.3 76.7 3

3 47.6 2.6 4

4

Table 9. Number of Individuals of Each Taxon of Fish Eggs and Larvae and Commercially or Recreationally Important Decapod Crustacean Larvae Captured Per Cubic Meter of Water Filtered During One 15-minute Bongo-Net Tow at Each Transect, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent numbers captured per cubic meter of water filtered at all six transects.)

TAXON SL 1 SL 2 SL 3 TOTAL A

C A

C A

C Archirus lineatus, post yolk-sac larvae 0.041 0.006 Bathygobius soporator, post yolk-sac larvae 0.031 0.017 0.038 0.012 Blenniidae spp., post yolk-sac larvae 0.052 0.462 0.048 Brevoortia smithi, post yolk-sac larvae 0.115 0.009 Carangidae, post yolk-sac larvae 0.020 0.003 Chasmodes saburrae, post yolk-sac larvae 0.020 0.003 Clupeidae spp., post yolk-sac larvae 14.000 0.325 0.339 1.224 0.038 0.203 3.036 Clupeidae spp., yolk-sac larvae 0.156 0.030 Cynoscion nebulous, post yolk-sac larvae 0.038 0.003 Cynoscion spp., post yolk-sac larvae 0.154 0.012 Gobiesox strumosus, post yolk-sac larvae 0.020 0.003 Gobiidae spp., post yolk-sac larvae 0.250 0.442 0.136 0.020 0.038 0.136 0.204 Gobiosoma robustum, post yolk-sac larvae 0.013 0.034 0.068 0.021 Lutjanidae spp., post yolk-sac larvae 0.020 0.003 Microgobius gulosus, post yolk-sac larvae 0.136 0.024 Perciformes spp., post yolk-sac larvae 0.247 0.041 0.038 0.066 Pleuronectiformes spp., post yolk-sac larvae 0.061 0.009 Sciaenidae spp., post yolk-sac larvae 0.102 0.115 1.017 0.204 Sciaenidae spp., yolk-sac larvae 0.094 0.269 0.039 Sphyraenidae spp., post yolk-sac larvae 0.052 0.012 Tetraodontidae spp., post yolk-sac larvae 0.052 0.012 Triglidae spp., post yolk-sac larvae 0.020 0.003 Unidentified fish fragment, post yolk-sac larvae 0.034 0.006

Table 9 (continued). Number of Individuals of Each Taxon of Fish Eggs and Larvae and Commercially or Recreationally Important Decapod Crustacean Larvae Captured Per Cubic Meter of Water Filtered During One 15-minute Bongo-Net Tow at Each Transect, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent numbers captured per cubic meter of water filtered at all six transects.)

TAXON SL 1 SL 2 SL 3 TOTAL A

C A

C A

C Clupeidae spp., eggs 4.656 0.273 5.593 9.385 0.339 2.734 Sciaenidae spp., eggs 0.094 0.154 0.068 0.042 Synodontidae spp., eggs 0.327 1.153 0.251 Unidentified fish eggs 11.406 13.273 15.220 7.000 19.923 16.203 13.374 Albunea sp., zoea 0.031 0.052 0.085 0.020 0.036 Callinectes spp., megalops 1.094 0.051 0.020 1.000 0.610 0.407 Callinectes spp., juvenile 0.038 0.003 Callinectes spp., zoea 0.623 0.068 6.224 1.038 0.339 1.210 Emerita talpoida, zoea 0.104 0.308 0.407 0.120 Hippidae spp., zoea 0.031 0.006 Menippe mercenaria, zoea 1.403 0.017 0.020 0.115 0.136 0.362 Penaeidae spp., mysis 0.154 0.068 0.024 Penaeidae spp., protozoea 0.063 0.104 0.085 0.490 0.123 TOTAL 31.906 17.013 21.678 15.694 33.423 20.881 22.458

Table 10. Number of Individuals of Each Species of Sea Turtle Sighted During Each of Two Passes Along Three One-Kilometer-Long Transects, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study.

SPECIES SL 1 SL 2 SL 3 Pass 1 Pass 2 Pass 1 Pass 2 Pass 1 Pass 2 Chelonia mydas (green turtle) 0 0

6 3

0 0

Florida Power & Light Company Biological Plan of Study Implementation for St. Lucie Plant EPU Baseline Event 4 Data Report Report to Florida Power & Light Company May 2012 Submitted by Ecological Associates, Inc.

Post Office Box 405 Jensen Beach, Florida

ECOLOGICAL ASSOCIATES, INC., JENSEN BEACH, FLORIDA INTRODUCTION During February and March 2012, Ecological Associates, Inc. (EAI) conducted the fourth baseline field sampling event in accordance with the St. Lucie Plant EPU Biological Plan of Study. During this fourth event, sampling was conducted on seven days between February 15 and March 1, 2012. Data collected included general environmental data; water quality data; numbers and sizes of fish and shellfish collected by gill net, trawl, and beach seine; numbers of fish eggs and larvae and commercially or recreationally important decapod crustacean larvae collected by plankton net; and, numbers and sizes of sea turtles observed. Results of the fourth sampling event are provided in this report. All data should be considered preliminary until quality assurance checks have been completed.

SAMPLING LOCATIONS Sampling was conducted within three separate sampling sites: SL1 located midway between the St. Lucie Plant and the Ft. Pierce Inlet, SL2 located in the vicinity of the St. Lucie Plant cooling water discharge, and SL3 located midway between the St. Lucie Plant and the St. Lucie Inlet.

For the purposes of gill netting and trawling, three transects were established within each of the three sampling sites: Transect A was located approximately 600 ft from shore on the beach terrace in water depths of 8-32 ft, Transect B was located approximately 4,000 ft. from shore in water depths of 34-44 ft, and Transect C was located approximately 8,000 ft. from shore in water depths of 31-46 ft. Plankton samples were collected concurrently with trawl samples at all three sites but only on Transects A and C.

Three stations were also established within each of the three sampling sites for the purpose of beach seining: Station A was located 0.5 mi. north of the center of the site, Station B was located at the center of the site, and Station C was located 0.5 mi. south of the center of the site.

At all stations, seines were pulled to the beach from a water depth of approximately 4 ft.

For the purpose of boat-based sea turtle surveys, one transect was established in each of the three sampling sites. The transects were located along nearshore hardbottom habitat in each site.

RESULTS Environmental data were recorded at each station during each day of sampling. Data recorded included sea conditions, air temperature, wind speed and direction, and sky conditions.

Environmental data are summarized by day in Table 1. Values reflect the range of values recorded throughout each day of sampling.

Water quality data were recorded at three locations and three depths along each of the nine transects established for trawl and gill net sampling. Data recorded included conductivity, water temperature, salinity, pH, and dissolved oxygen (DO). Water quality data are provided in Table

2.

BASELINE EVENT 4 DATA REPORT, ST. LUCIE PLANT EPU BIOLOGICAL STUDY ECOLOGICAL ASSOCIATES, INC., JENSEN BEACH, FLORIDA 2

Trawls were towed for 15 minutes along each of the nine transects. The numbers of fish and commercially or recreationally important shellfish collected in each 15-minute tow are presented in Table 3. Because of variations in tow speed, the distances the trawl traveled during a 15-minute tow varied (based on GPS readings). In order to compare abundances among stations in terms of catch per unit effort, the numbers collected per kilometer of bottom sampled were calculated and are presented in Table 4.

The numbers of fish and commercially or recreationally important shellfish collected by gill net on each of the nine transects is given in Table 5. At each transect the gill net began to be retrieved 30 minutes after it was set. However, the total soak time (time from when the net first entered the water until the time it was completely removed from the water) varied among transects because of differences in retrieval times associated with variations in the number of fish present in the net. In order to compare abundances among stations in terms of catch per unit effort, the numbers collected per hour of total soak time were calculated and are given in Table

6.

Beach seines were deployed at each of the nine stations previously described. The numbers of fish and commercially or recreationally important shellfish collected at each station are presented in Table 7.

A maximum of 25 representative specimens of each Representative Important Species (RIS) of fish collected at each transect/station by trawl, gill net, and beach seine were measured (total length) and a batch weight for those specimens was obtained. Average lengths and average weights of each RIS at each station/transect for each gear type are presented in Table 8.

Bongo nets were used to collect fish eggs and larvae as well as commercially or recreationally important decapod crustacean larvae at each of the six transects previously described. Nets were pulled for 15 minutes and the volume of water filtered determined by means of flow meters.

Numbers of individuals per cubic meter of water filtered are given in Table 9.

To quantify the number of sea turtles present in each of the three sampling sites, one one-kilometer-long transect in each sampling site was traversed by boat twice. The numbers of sea turtles sighted during each pass along each transect are presented in Table 10.

Table 1. Environmental Data, Baseline Sampling Event 4 (February - March 2012), St. Lucie Plant EPU Biological Study. Values reflect the range of values recorded throughout each day of sampling.

Sampling Date Sea Conditions Air Temp Wind Speed/Direction Sky Conditions Trawls/

Ichthyoplankton 2/23/2012 Calm to 2-3 ft swell 21.5-28.5°C 3-10 mph/SE to WSW Clear Trawls/

Ichthyoplankton 2/24/2012 1-4 ft swell 21.0-27.0°C 3-15 mph/SW to W Clear Gill Nets 2/15/2012 1-3 ft swell 21.3-26.7°C 5-10 mph/S to SE Clear to Partly Cloudy Gill Nets 2/16/2012 2-3 ft swell 21.4-22.8°C 5-10 mph/S to SE Mostly Cloudy Gill Nets 2/17/2012 calm 23.4°C 0-3 mph/S Partly Cloudy Beach Seines 3/1/2012 1-3 ft swell 21.7-32.1°C 0-7 mph/S Clear to Mostly Cloudy Sea Turtle Transects 2/24/2012 2 ft swell, slight chop 24.4°C 5-7 mph/SW to SSW Partly Cloudy

Table 2. Water Quality Data, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. NR = not recorded Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Trawl SL1 A North Surface 55.60 22.87 36.75 8.20 6.53 Mid-Depth 55.50 22.92 36.75 8.20 6.50 Bottom 55.60 22.92 36.68 8.20 6.43 Middle Surface 55.50 23.01 36.68 8.18 6.65 Mid-Depth 56.60 23.01 36.76 8.19 6.50 Bottom 55.50 23.00 36.76 8.19 6.55 South Surface 55.50 23.13 36.76 8.18 6.90 Mid-Depth 55.60 23.15 36.76 8.18 6.79 Bottom 55.50 23.15 36.69 8.19 6.68 Trawl SL1 B North Surface 55.50 23.31 36.77 8.21 6.46 Mid-Depth 55.50 23.32 36.77 8.21 6.56 Bottom 55.50 23.32 36.70 8.21 6.51 Middle Surface 55.70 23.31 36.85 8.20 6.48 Mid-Depth 55.50 23.33 36.70 8.20 6.58 Bottom 55.50 23.32 36.70 8.20 6.48 South Surface 55.60 23.36 36.78 8.17 6.57 Mid-Depth 55.50 23.36 36.77 8.18 6.57 Bottom 55.50 23.32 36.77 8.19 6.49 Trawl SL1 C North Surface 55.60 23.34 36.78 8.17 6.67 Mid-Depth 55.60 23.34 36.78 8.19 6.62 Bottom 55.50 23.35 36.70 8.20 6.54 Middle Surface 55.60 23.24 36.77 8.21 6.54 Mid-Depth 55.60 23.31 36.77 8.21 6.57 Bottom 55.50 23.32 36.77 8.21 6.51 South Surface 55.60 23.24 36.77 8.21 6.66 Mid-Depth 55.60 23.24 36.77 8.21 6.61 Bottom 55.50 23.30 36.70 8.22 6.62 Trawl SL2 A North Surface 55.60 23.50 36.78 8.16 6.56 Mid-Depth 55.60 23.44 36.78 8.18 6.57 Bottom 55.50 23.35 36.70 8.19 6.47 Middle Surface 55.60 23.58 36.71 8.20 6.42 Mid-Depth 55.50 23.33 36.70 8.20 6.53 Bottom 55.60 23.18 36.69 8.21 6.43 South Surface 55.50 23.73 36.72 8.21 6.52 Mid-Depth 55.50 23.24 36.77 8.21 6.43 Bottom 55.60 23.19 36.69 8.21 6.48

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Trawl SL2 B North Surface 55.60 23.30 36.77 8.21 6.67 Mid-Depth 55.60 23.32 36.77 8.22 6.70 Bottom 55.60 23.31 36.77 8.22 6.59 Middle Surface 55.60 23.16 36.76 8.22 6.56 Mid-Depth 55.60 23.18 36.69 8.22 6.49 Bottom 55.70 23.16 36.69 8.22 6.74 South Surface 55.60 23.06 36.76 8.23 6.63 Mid-Depth 55.60 23.10 36.76 8.22 6.64 Bottom 55.60 23.09 36.69 8.23 6.89 Trawl SL2 C North Surface 55.60 23.29 36.77 8.21 6.62 Mid-Depth 55.60 23.31 36.77 8.22 6.57 Bottom 55.50 23.31 36.70 8.22 6.51 Middle Surface 55.70 23.18 36.84 8.23 6.67 Mid-Depth 55.70 23.18 36.77 8.23 6.71 Bottom 55.60 23.23 36.77 8.23 6.58 South Surface 55.60 23.21 36.84 8.23 6.46 Mid-Depth 55.60 23.23 36.77 8.23 6.68 Bottom 55.50 23.22 36.77 8.23 6.63 Trawl SL3 A North Surface 55.70 23.39 36.85 8.22 6.37 Mid-Depth 55.70 23.39 36.85 8.22 6.50 Bottom 55.70 23.40 36.85 8.22 6.45 Middle Surface 55.70 23.39 36.85 8.20 6.40 Mid-Depth 55.70 23.41 36.85 8.21 6.51 Bottom 55.70 23.41 36.85 8.21 6.57 South Surface 55.70 23.40 36.85 8.18 6.63 Mid-Depth 55.70 23.40 36.78 8.19 6.57 Bottom 55.70 23.43 36.85 8.19 6.50 Trawl SL3 B North Surface 55.70 23.47 36.86 8.19 6.50 Mid-Depth 55.70 23.47 36.86 8.20 6.44 Bottom 55.60 23.46 36.78 8.20 6.45 Middle Surface 55.70 23.48 36.86 8.21 6.49 Mid-Depth 55.60 23.49 36.78 8.21 6.47 Bottom 55.60 23.49 36.78 8.21 6.39 South Surface 55.70 23.55 36.86 8.21 6.49 Mid-Depth 55.60 23.59 36.79 8.22 6.49 Bottom 55.60 23.59 36.79 8.21 6.43

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Trawl SL3 C North Surface 55.80 23.34 36.92 8.19 6.62 Mid-Depth 55.70 23.15 36.91 8.20 6.69 Bottom 55.80 22.54 36.96 8.18 6.13 Middle Surface 55.80 23.34 37.00 8.22 6.41 Mid-Depth 55.70 23.20 36.84 8.22 6.56 Bottom 55.90 22.31 36.87 8.19 5.95 South Surface 55.90 23.25 36.99 8.23 6.58 Mid-Depth 55.70 23.21 36.84 8.23 6.55 Bottom 55.80 22.65 36.89 8.21 6.03 Gill Net SL1 A West Surface 54.80 20.24 35.99 8.11 7.32 Mid-Depth 54.90 20.16 36.06 8.12 7.12 Bottom 54.90 20.10 36.06 8.13 6.98 Middle Surface 54.80 20.32 36.00 7.99 7.92 Mid-Depth 54.90 20.15 36.06 8.04 6.98 Bottom 55.00 20.08 36.06 8.06 6.97 East Surface 54.80 20.36 36.00 8.09 7.37 Mid-Depth 54.90 20.17 36.06 8.09 6.99 Bottom 55.00 20.11 36.13 8.10 6.97 Gill Net SL1 B West Surface 54.80 20.66 36.10 8.09 7.44 Mid-Depth 54.80 20.54 36.01 8.13 6.75 Bottom 54.80 20.53 36.01 8.13 6.67 Middle Surface 55.00 20.81 36.10 8.14 7.02 Mid-Depth 54.90 20.60 36.09 8.15 6.80 Bottom 54.80 20.58 36.01 8.15 6.75 East Surface 54.80 20.74 36.02 8.16 6.89 Mid-Depth 54.90 20.63 36.09 8.16 6.80 Bottom 54.80 20.60 36.02 8.16 6.73 Gill Net SL1 C West Surface 54.70 22.03 36.08 8.16 7.01 Mid-Depth 55.00 21.03 36.12 8.17 6.91 Bottom 54.90 20.98 36.11 8.18 6.89 Middle Surface 54.80 21.80 36.17 8.19 6.83 Mid-Depth 54.90 21.06 36.12 8.19 6.87 Bottom 54.90 21.01 36.11 8.19 6.84 East Surface 54.70 21.68 36.01 8.19 6.74 Mid-Depth 54.90 21.09 36.12 8.19 6.76 Bottom 55.00 21.04 36.12 8.19 6.79

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Gill Net SL2 A West Surface 54.50 22.40 35.90 8.10 7.07 Mid-Depth 54.60 21.63 35.85 8.13 7.00 Bottom 54.60 21.22 35.90 8.13 7.04 Middle Surface 54.60 22.33 35.90 8.14 6.75 Mid-Depth 54.60 21.67 35.93 8.15 6.84 Bottom 54.70 21.08 35.90 8.16 6.90 East Surface 54.50 22.55 35.91 8.16 6.72 Mid-Depth 54.60 21.58 35.93 8.17 6.76 Bottom 54.60 21.36 35.91 8.17 6.79 Gill Net SL2 B West Surface 54.50 23.17 35.95 7.98 7.06 Mid-Depth 54.60 21.89 35.95 8.07 6.91 Bottom 54.70 21.22 35.91 8.08 6.79 Middle Surface 54.40 23.28 35.95 8.12 6.63 Mid-Depth 54.60 21.37 35.95 8.12 6.72 Bottom 54.70 21.32 35.99 8.12 6.60 East Surface 54.50 23.33 35.95 8.14 6.50 Mid-Depth 54.60 21.91 35.95 8.14 6.65 Bottom 54.70 21.48 35.92 8.14 6.63 Gill Net SL2 C West Surface 54.70 23.19 36.10 8.15 6.78 Mid-Depth 54.60 22.57 35.91 8.17 6.81 Bottom 54.60 21.94 35.96 8.17 6.78 Middle Surface 54.50 23.22 35.95 8.18 6.66 Mid-Depth 54.50 22.64 35.92 8.19 6.64 Bottom 54.60 22.26 35.98 8.19 6.66 East Surface 54.50 23.25 35.88 8.19 6.57 Mid-Depth 54.50 22.56 35.99 8.19 6.63 Bottom 54.60 22.18 35.96 8.19 6.66 Gill Net SL3 A West Surface 54.10 22.60 35.60 7.77 6.33 Mid-Depth 54.00 22.40 35.50 7.75 6.33 Bottom 54.00 22.40 35.50 7.74 6.26 Middle Surface 54.10 22.70 35.60 7.81 6.52 Mid-Depth 54.10 22.50 35.50 7.81 6.47 Bottom 54.10 22.40 35.60 7.79 6.55 East Surface 54.10 22.60 35.60 7.82 6.61 Mid-Depth 54.30 22.70 35.80 7.81 6.49 Bottom 54.10 22.30 35.60 7.81 6.65

Table 2 (Continued). Water Quality Data, Baseline Sampling Event 4 (February 2012), St.

Lucie Plant EPU Biological Study.

Transect Station Depth Conductivity (mS/cm)

Water Temp (°C)

Salinity (PSU) pH DO (mg/l)

Gill Net SL3 B West Surface 54.20 22.80 35.70 7.80 6.33 Mid-Depth 54.20 22.80 35.70 7.80 6.17 Bottom 54.50 22.80 35.90 7.77 6.26 Middle Surface 54.20 22.70 35.70 7.81 6.52 Mid-Depth 54.20 22.90 35.70 7.81 6.42 Bottom 54.50 22.60 35.80 7.79 6.37 East Surface 54.20 22.80 35.70 7.81 6.71 Mid-Depth 54.10 22.80 35.70 7.81 6.71 Bottom 54.50 23.00 35.90 7.80 6.53 Gill Net SL3 C West Surface 54.40 22.93 35.86 7.80 6.22 Mid-Depth 54.40 22.94 35.78 7.81 6.22 Bottom 54.70 22.57 35.99 7.80 6.11 Middle Surface 54.30 22.95 35.79 7.82 6.43 Mid-Depth 54.30 22.93 35.78 7.81 6.42 Bottom 54.70 22.53 36.06 7.80 6.29 East Surface 54.30 22.96 35.79 7.81 6.50 Mid-Depth 54.30 22.93 35.78 7.81 6.48 Bottom 54.60 22.54 36.06 7.79 6.39

Table 3. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Trawl during One 15-minute Tow at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study.

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Callinectes ornatus (shelligs) 2 2

Farfantepenaeus aztecus (brown shrimp) 3 3

Farfantepenaeus duorarum (pink shrimp) 2 1

3 Penaeidae sp. (penaeid shrimp) 3 3

Rimapenaeus sp.

1 2

3 1

5 12 Anisotremus surinamensis (black margate) 1 1

Centropristis striata (black sea bass) 1 1

Corvula sanctaeluciae (stripped croaker) 2 2

Cynoscion nebulosus (spotted seatrout) 1 1

Labridae sp. (wrass) 1 1

Labrisomas nuchipinnis (hairy blenny) 3 3

Lagodon rhomboides (pinfish) 1 2

3 Leiostomus xanthurus (spot) 5 3

8 Menticirrhus littoralis (Gulf kingfish) 1 1

Micropogonias undulatus (Atlantic croaker) 4 4

Ophidion holbrookii (bank cusk-eel) 1 1

Prionotus scitulus (leopard searobin) 1 1

2 Prionotus sp. (searobin) 1 1

Trachinotus carolinus (Florida pompano) 1 1

Umbrina coroides (sand drum) 3 3

TOTAL 24 5

0 19 1

1 6

0 0

56

Table 4. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured per Kilometer by Trawl at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent the number of individuals captured per kilometer for all nine transects.)

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Callinectes ornatus (shelligs) 1.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 Farfantepenaeus aztecus (brown shrimp) 0.0 0.0 0.0 2.4 0.0 0.0 0.0 0.0 0.0 0.3 Farfantepenaeus duorarum (pink shrimp) 1.7 0.0 0.0 0.8 0.0 0.0 0.0 0.0 0.0 0.3 Penaeidae sp. (penaeid shrimp) 0.0 2.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 Rimapenaeus sp.

0.9 1.5 0.0 2.4 0.7 0.0 7.8 0.0 0.0 1.2 Anisotremus surinamensis (black margate) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Centropristis striata (black sea bass) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Corvula sanctaeluciae (stripped croaker) 1.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 Cynoscion nebulosus (spotted seatrout) 0.0 0.0 0.0 0.8 0.0 0.0 0.0 0.0 0.0 0.1 Labridae sp. (wrass) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Labrisomas nuchipinnis (hairy blenny) 2.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 Lagodon rhomboides (pinfish) 0.9 0.0 0.0 1.6 0.0 0.0 0.0 0.0 0.0 0.3 Leiostomus xanthurus (spot) 4.3 0.0 0.0 2.4 0.0 0.0 0.0 0.0 0.0 0.8 Menticirrhus littoralis (gulf kingfish) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Micropogonias undulatus (Atlantic croaker) 0.0 0.0 0.0 3.2 0.0 0.0 0.0 0.0 0.0 0.4 Ophidion holbrookii (bank cusk-eel) 0.0 0.0 0.0 0.8 0.0 0.0 0.0 0.0 0.0 0.1 Prionotus scitulus (leopard searobin) 0.0 0.0 0.0 0.8 0.0 0.9 0.0 0.0 0.0 0.2 Prionotus sp. (searobin) 0.0 0.0 0.0 0.0 0.0 0.0 1.6 0.0 0.0 0.1 Trachinotus carolinus (Florida pompano) 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Umbrina coroides (sand drum) 2.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 TOTAL 20.7 3.8 0.0 15.3 0.7 0.9 9.4 0.0 0.0 5.4

Table 5. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Gill Net at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study.

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Arenaeus cribrarius (speckled swimming crab) 1 1

Brevoortia smithi (yellowfin menhaden) 8 8

4 5

37 62 Caranx crysos (blue runner) 1 1

2 9

5 5

23 Caranx hippos (crevalle jack) 4 4

Carcharhinus brevipinna (spinner shark) 2 10 1

1 14 Centropristis striata (black sea bass) 1 1

Chloroscombrus chrysurus (Atlantic bumper) 9 312 75 9

405 Echeneis naucrates (sharksucker) 1 1

Leiostomus xanthurus (spot) 1 1

Lutjanus synagris (lane snapper) 2 2

Menticirrhus americanus (southern kingfish) 10 1

13 24 Menticirrhus littoralis (Gulf kingfish) 1 1

Micropogonias undulatus (Atlantic croaker) 1 14 15 Orthopristis chrysoptera (pigfish) 3 11 14 Paralichtys albigutta (Gulf flounder) 2 2

Pomatomus saltatrix (bluefish) 11 2

3 16 Rachycentron canadum (cobia) 1 1

2 Rhizoprionodon terraenovae (Atlantic sharpnose shark) 3 20 105 99 227 Scomberomorus maculatus (Spanish mackerel) 8 3

11 Selene setapinnis (Atlantic moonfish) 1 1

Sphyrna tiburo (bonnethead) 11 82 93 Synodus foetens (inshore lizardfish) 7 1

26 34 Trachinotus carolinus (Florida pompano) 1 1

TOTAL 28 55 7

11 325 35 8

377 109 955

Table 6. Catch Per Unit Effort (Number of Individuals Per Hour of Soak Time) for Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Gill Net at Each Station, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent the number of individuals captured per hour for all nine transects.)

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Arenaeus cribrarius (speckled swimming crab) 1.25 0.10 Brevoortia smithi (yellowfin menhaden) 9.23 7.87 3.12 7.69 12.83 6.00 Caranx crysos (blue runner) 1.15 0.98 2.40 11.25 3.90 5.17 2.23 Caranx hippos (crevalle jack) 1.39 0.39 Carcharhinus brevipinna (spinner shark) 2.40 10.34 0.35 0.97 1.35 Centropristis striata (black sea bass) 0.78 0.10 Chloroscombrus chrysurus (Atlantic bumper) 8.85 243.12 26.01 8.71 39.19 Echeneis naucrates (sharksucker) 0.35 0.10 Leiostomus xanthurus (spot) 0.35 0.10 Lutjanus synagris (lane snapper) 3.08 0.19 Menticirrhus americanus (southern kingfish) 9.84 1.25 4.51 2.32 Menticirrhus littoralis (Gulf kingfish) 0.35 0.10 Micropogonias undulatus (Atlantic croaker) 0.98 4.86 1.45 Orthopristis chrysoptera (pigfish) 2.95 3.82 1.35 Paralichtys albigutta (Gulf flounder) 1.56 0.19 Pomatomus saltatrix (bluefish) 12.69 1.97 1.04 1.55 Rachycentron canadum (cobia) 1.54 0.35 0.19 Rhizoprionodon terraenovae (Atlantic sharpnose shark) 3.60 20.69 36.42 95.81 21.97 Scomberomorus maculatus (Spanish mackerel) 9.23 2.95 1.06 Selene setapinnis (Atlantic moonfish) 0.35 0.10 Sphyrna tiburo (bonnethead) 10.82 28.44 9.00 Synodus foetens (inshore lizardfish) 6.89 0.78 9.02 3.29 Trachinotus carolinus (Florida pompano) 0.35 0.10 TOTAL 32.31 54.10 8.40 13.75 253.25 36.21 12.31 130.75 105.48 92.42

Table 7. Number of Individuals of Each Taxon of Fish and Commercially or Recreationally Important Shellfish Captured by Beach Seine at Each Station, Baseline Sampling Event 4 (March 2012), St. Lucie Plant EPU Biological Study.

TAXON SL1 SL2 SL3 TOTAL A

B C

A B

C A

B C

Arenaeus cribrarius (speckled swimming crab 1

1 Emerita sp.

2 2

Bairdiella chrysoura (silver perch) 5 1

6 Chloroscombrus chrysurus (Atlantic bumper) 1 1

Menticirrhus littoralis (Gulf kingfish) 1 1

1 3

6 Polydactylus virginicus (barbu) 1 1

Selene vomer (lookdown) 1 1

1 6

9 Trachinotus falcatus (permit) 1 1

2 Umbrina coroides (sand drum) 2 1

1 4

TOTAL 9

5 0

2 1

2 3

1 9

32

Table 8. Average total length (TL) and average weight (W) of each Representative Important Species Captured by Gill Net, Trawl, and Beach Seine, Baseline Sampling Event 4 (February-March 2012), St. Lucie Plant EPU Biological Study. For each species the number weighed/measured (n) and the total number collected (N) are given.

TAXON Gill Net Trawl Beach Seine TL (mm)

W (g) n N

TL (mm)

W (g) n N

TL (mm)

W (g) n N

Brevoortia smithi (yellowfin menhaden) 336.3 422.8 41 62 Leiostomus xanthurus (spot) 258.0 192.0 1

1 192.3 92.3 7

8 Menticirrhus americanus (southern kingfish) 351.4 467.2 23 24 Menticirrhus littoralis (Gulf kingfish) 377.0 545.0 1

1 227.0 113.0 1

1 124.9 132.1 6

6 Micropogonias undulatus (Atlantic croaker) 249.1 166.7 15 15 241.5 168.5 4

4 Orthopristis chrysoptera (pigfish) 246.1 214.4 13 14 Pomatomus saltatrix (bluefish) 405.0 632.8 16 16 Prionotus scitulus (leopard searobin) 196.5 55.4 2

2 Scomberomorus maculatus (Spanish mackerel) 459.4 500.0 11 11 Trachinotus carolinus (Florida pompano) 277.0 266.0 1

1 149.0 45.3 1

1 Umbrina coroides (sand drum) 181.3 76.7 3

3 47.6 2.6 4

4

Table 9. Number of Individuals of Each Taxon of Fish Eggs and Larvae and Commercially or Recreationally Important Decapod Crustacean Larvae Captured Per Cubic Meter of Water Filtered During One 15-minute Bongo-Net Tow at Each Transect, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent numbers captured per cubic meter of water filtered at all six transects.)

TAXON SL 1 SL 2 SL 3 TOTAL A

C A

C A

C Archirus lineatus, post yolk-sac larvae 0.041 0.006 Bathygobius soporator, post yolk-sac larvae 0.031 0.017 0.038 0.012 Blenniidae spp., post yolk-sac larvae 0.052 0.462 0.048 Brevoortia smithi, post yolk-sac larvae 0.115 0.009 Carangidae, post yolk-sac larvae 0.020 0.003 Chasmodes saburrae, post yolk-sac larvae 0.020 0.003 Clupeidae spp., post yolk-sac larvae 14.000 0.325 0.339 1.224 0.038 0.203 3.036 Clupeidae spp., yolk-sac larvae 0.156 0.030 Cynoscion nebulous, post yolk-sac larvae 0.038 0.003 Cynoscion spp., post yolk-sac larvae 0.154 0.012 Gobiesox strumosus, post yolk-sac larvae 0.020 0.003 Gobiidae spp., post yolk-sac larvae 0.250 0.442 0.136 0.020 0.038 0.136 0.204 Gobiosoma robustum, post yolk-sac larvae 0.013 0.034 0.068 0.021 Lutjanidae spp., post yolk-sac larvae 0.020 0.003 Microgobius gulosus, post yolk-sac larvae 0.136 0.024 Perciformes spp., post yolk-sac larvae 0.247 0.041 0.038 0.066 Pleuronectiformes spp., post yolk-sac larvae 0.061 0.009 Sciaenidae spp., post yolk-sac larvae 0.102 0.115 1.017 0.204 Sciaenidae spp., yolk-sac larvae 0.094 0.269 0.039 Sphyraenidae spp., post yolk-sac larvae 0.052 0.012 Tetraodontidae spp., post yolk-sac larvae 0.052 0.012 Triglidae spp., post yolk-sac larvae 0.020 0.003 Unidentified fish fragment, post yolk-sac larvae 0.034 0.006

Table 9 (continued). Number of Individuals of Each Taxon of Fish Eggs and Larvae and Commercially or Recreationally Important Decapod Crustacean Larvae Captured Per Cubic Meter of Water Filtered During One 15-minute Bongo-Net Tow at Each Transect, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study. (Note: Totals in the right column represent numbers captured per cubic meter of water filtered at all six transects.)

TAXON SL 1 SL 2 SL 3 TOTAL A

C A

C A

C Clupeidae spp., eggs 4.656 0.273 5.593 9.385 0.339 2.734 Sciaenidae spp., eggs 0.094 0.154 0.068 0.042 Synodontidae spp., eggs 0.327 1.153 0.251 Unidentified fish eggs 11.406 13.273 15.220 7.000 19.923 16.203 13.374 Albunea sp., zoea 0.031 0.052 0.085 0.020 0.036 Callinectes spp., megalops 1.094 0.051 0.020 1.000 0.610 0.407 Callinectes spp., juvenile 0.038 0.003 Callinectes spp., zoea 0.623 0.068 6.224 1.038 0.339 1.210 Emerita talpoida, zoea 0.104 0.308 0.407 0.120 Hippidae spp., zoea 0.031 0.006 Menippe mercenaria, zoea 1.403 0.017 0.020 0.115 0.136 0.362 Penaeidae spp., mysis 0.154 0.068 0.024 Penaeidae spp., protozoea 0.063 0.104 0.085 0.490 0.123 TOTAL 31.906 17.013 21.678 15.694 33.423 20.881 22.458

Table 10. Number of Individuals of Each Species of Sea Turtle Sighted During Each of Two Passes Along Three One-Kilometer-Long Transects, Baseline Sampling Event 4 (February 2012), St. Lucie Plant EPU Biological Study.

SPECIES SL 1 SL 2 SL 3 Pass 1 Pass 2 Pass 1 Pass 2 Pass 1 Pass 2 Chelonia mydas (green turtle) 0 0

6 3

0 0