2015 Dresden Station Initial License Examination References Provided for 2015 Written Examination
ML15303A128
Person / Time
Site: Dresden  
Issue date: 04/30/2015
From: Randy Baker
Operations Branch III
To:
Exelon Nuclear
References
Download: ML15303A128 (1)


Text

REFERENCES PROVIDED FOR REACTOR OPERATOR EXAMINATION Heat Capacity Limit, Attachment G, Optimized Limit Curves; Revision 13 DOP 6400-08, Figure 5, Dresden Unit 3 Generator Capability Curves and Under Excitation Limiter Settings - Automatic Voltage Regulator in Auto Mode (UEL Settings); Revision 34 DOP 6400-08, Figure 6, Dresden Unit 3 Generator Capability Curves and Manual Operation Limit - Automatic Voltage Regulator in Manual Mode (MOL Settings); Revision 34 DOP 6400-08, Figure 7, Dresden Unit 3 Generator Capability Curves (Expanded View)

Automatic Voltage Regulator in Auto Mode; Revision 34 DEOP 100, RPV Control (Modified - Entry Conditions Removed); Rev 10 DEOP 200-2, Hydrogen Control (Modified - Entry Conditions Removed); Rev 04 DEOP 300-1, Secondary Containment Control (Modified - Entry Conditions Removed); Rev 02 DEOP 300-2, Radioactivity Release Control (Modified - Entry Conditions Removed); Rev 02 DEOP 400-1, RPV Flooding (Modified - Entry Conditions Removed) Rev 07 DEOP 400-2, Emergency Depressurization (Modified - Entry Conditions Removed) Rev 06 DEOP 400-3, Steam Cooling (Modified - Entry Conditions Removed); Rev 05 DEOP 400-5, Failure to Scram (Modified - Entry Conditions Removed); Rev 16 ADDITIONAL REFERENCES PROVIDED FOR THE SRO EXAMINATION Technical Specification 3.5.1, ECCS-Operating; Amendment No.233/226 Technical Requirements Manual 3.4.b, Reactor Coolant System (RCS) Chemistry; Revision 5 Technical Specification 3.3.1.1, Reactor Protection System (RPS) Instrumentation; Amendment No. 185/180 12E-2464, Schematic Diagram, Reactor Protection System, Channel A Trip Auxiliary Relays EP-AA-1004, Addendum 3, Hot Matrix; Rev 0 DP-AA-1004, Addendum 3, Cold Shutdown/Refueling Matrix; Rev 0

REFERENCES PROVIDED FOR REACTOR OPERATOR EXAMINATION Heat Capacity Limit, Attachment G, Optimized Limit Curves; Revision 13 DOP 6400-08, Figure 5, Dresden Unit 3 Generator Capability Curves and Under Excitation Limiter Settings - Automatic Voltage Regulator in Auto Mode (UEL Settings); Revision 34 DOP 6400-08, Figure 6, Dresden Unit 3 Generator Capability Curves and Manual Operation Limit - Automatic Voltage Regulator in Manual Mode (MOL Settings); Revision 34 DOP 6400-08, Figure 7, Dresden Unit 3 Generator Capability Curves (Expanded View)

Automatic Voltage Regulator in Auto Mode; Revision 34 DEOP 100, RPV Control (Modified - Entry Conditions Removed); Rev 10 DEOP 200-2, Hydrogen Control (Modified - Entry Conditions Removed); Rev 04 DEOP 300-1, Secondary Containment Control (Modified - Entry Conditions Removed); Rev 02 DEOP 300-2, Radioactivity Release Control (Modified - Entry Conditions Removed); Rev 02 DEOP 400-1, RPV Flooding (Modified - Entry Conditions Removed) Rev 07 DEOP 400-2, Emergency Depressurization (Modified - Entry Conditions Removed) Rev 06 DEOP 400-3, Steam Cooling (Modified - Entry Conditions Removed); Rev 05 DEOP 400-5, Failure to Scram (Modified - Entry Conditions Removed); Rev 16 ADDITIONAL REFERENCES PROVIDED FOR THE SRO EXAMINATION Technical Specification 3.5.1, ECCS-Operating; Amendment No.233/226 Technical Requirements Manual 3.4.b, Reactor Coolant System (RCS) Chemistry; Revision 5 Technical Specification 3.3.1.1, Reactor Protection System (RPS) Instrumentation; Amendment No. 185/180 12E-2464, Schematic Diagram, Reactor Protection System, Channel A Trip Auxiliary Relays EP-AA-1004, Addendum 3, Hot Matrix; Rev 0 DP-AA-1004, Addendum 3, Cold Shutdown/Refueling Matrix; Rev 0