RC-15-0142, License Amendment Request, LAR 12-04269, License Basis Changes in Steam Generator Tube Rupture Analysis, Response to Request for Additional Information

From kanterella
(Redirected from ML15258A021)
Jump to navigation Jump to search

License Amendment Request, LAR 12-04269, License Basis Changes in Steam Generator Tube Rupture Analysis, Response to Request for Additional Information
ML15258A021
Person / Time
Site: Summer 
(NPF-012)
Issue date: 09/10/2015
From: Gatlin T
South Carolina Electric & Gas Co
To: Shawn Williams
Document Control Desk, Office of Nuclear Reactor Regulation
References
LAR-12-04269, RC-15-0142
Download: ML15258A021 (5)


Text

Thomas D. Gatlin Vice President, Nuclear Operations 803.345.4342 A SCANA COMPANY September 10, 2015 RC-15-0142 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Attn: S. A. Williams

Dear Sir / Madam:

Subject:

VIRGIL C. SUMMER NUCLEAR STATION (VCSNS) UNIT I DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 LICENSE AMENDMENT REQUEST - LAR-12-04269 LICENSE BASIS CHANGES IN STEAM GENERATOR TUBE RUPTURE ANALYSIS RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION

References:

1. SCE&G Letter from Thomas D. Gatlin to NRC Document Control Desk, License Amendment Request - LAR-12-04269, "License Basis Changes in Steam Generator Tube Rupture Analysis," dated August 27, 2014

[MLI14245A408]

2. NRC Letter from Shawn A. Williams to Thomas D. Gatlin, "Virgil C. Summer Nuclear Station, Unit No. 1, Request for Additional Information Regarding License Basis Changes in Steam Generator Tube Rupture Analysis (TAC NO.

MF4699)," dated April 13, 2015 [ML15076A118]

3. SCE&G Letter from Thomas D. Gatlin to NRC Document Control Desk, License Amendment Request - LAR-12-04269, "License Basis Changes in Steam Generator Tube Rupture Analysis," dated May 12, 2015

[MLI151 35A238]

South Carolina Electric & Gas Company (SCE&G), acting for itself and as agent for South Carolina Public Service Authority pursuant to 10 CFR 50.90, submitted License Amendment Request (LAR) per Reference I concerning license basis, changes in the steam generator tube rupture analysis. NRC review of this request determined that additional information was required and a request for additional information (RAl) was issued per Reference 2. This letter contains the responses to PAls No. 1 and No. 3 as committed to in Reference 3.

There are no regulatory commitments associated with this response.

V. C. Summer Nuclear Station

  • P. 0. Box 88
  • Jenkinsville, SC.29065.* F (803) 941-9776

, i

Document Control Desk CR-I12-04269 RC-1 5-0 142 Page 2 of 2 If you have any questions regarding this submittal, please contact Mr. Bruce L. Thompson at (803) 931-5042.

I certify under penalty of perjury that the foregoing is correct and true.

Executed on Thomas D. Gatlin TS/TDG/wm

Attachment:

VCSNS Response to Request for Additional Information

Enclosure:

2 Compact Disks with Three-Year Meteorological Data in ARCON Format c:

K. B. Marsh S. A. Byrne J. B. Archie N. S. Camns J. H. Hamilton J. W. Williams W. M. Cherry V. M. McCree S. A. Williams NRC Resident Inspector S. E. Jenkins Paulette Ledbetter K. M. Sutton NSRC RTS (CR-12-04269)

Files (813.20)

PRSF (RC-15-0142)

Document Control Desk Attachment CR-i12-04269 RC-15-0142 Page 1 of 3 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS) UNIT 1 DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ATTACHMENT VCSNS RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION

Document Control Desk Attachment CR-I12-04269 RC-1 5-0142 Page 2 of 3 The U.S. Nuclear Regulatory Commission (NRC) staff reviewed the Virgil C. Summer Nuclear Station License Amendment Request (LAR), dated August 27, 2014 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML14245A408) and supplements dated October 31, 2014, and February 12, 2015 (ADAMS Accession Nos.

ML14308A075 and ML15055A143, respectively). The NRC staff has determined that the following requests for additional information (RAI) are required to complete the review.

RAI No. I In the NRC staff's Safety Evaluation dated October 4, 2010 (ADAMS Accession No. ML102160020), approving the Alternative Source Term (AST), Section 3.1.1 it states:

"However, because of the apparent uncertainties discussed above, the NRC staff notes that these data may not be considered acceptable for use in other dose assessments of other meteorological applications without further NRC review and approval."

Therefore, please provide the most recent 3 years, with 90% recovery rate (per RG 1.230),

of current meteorological data so that the staff can perform an assessment of the proposed */Qs.

SCE&G Response Three-Year meteorological data (01/01/2012 - 12/31/2014) have been developed as requested and are included in the attached compact disk in ARCON format for convenience.

RAI No. 3 Page 35 of the August 27, 2014, submittal, states that the atmospheric dispersion factors are presented in Table 11. A review of Table 11 shows that the values used are the same as those contained in the following application:

Letter from SCE&G to NRC, "License Amendment and Related Technical Specification Changes to Implement Full-Scope Alternative Source Term in Accordance with 10 CFR 50.67," February 17, 2009. (ADAMS Accession No. ML090720887)

In the NRC staff's approval of this application it states, "Therefore, the X/Q values should not be considered acceptable for use in other dose assessments or other meteorological applications without further NRC review and approval."

Given that the staff previously stated that these values should not be considered acceptable, please provide justification for using these values and demonstrate that these values are still appropriate with a more recent data set that does not have the uncertainties that were inherent in the previously provided data set.

Document Control Desk Attachment CR-I12-0426 9 RC-I15-0142 Page 3 of 3 SCE&G Response The updated meteorological data was used to derive atmospheric dispersion (x/Q) values at the Exclusion Area Boundary (EAB) and Low Population Zone (LPZ) at certain time intervals using the PAVAN code. The values are shown below and are compared to those used as input to the August 27, 2014 submittal [ML14245A408].

Time Per-iod*,,IQ,

  • /(s-ec/in 3)...

-,::Current

,Updated.

EAB

, EAB 0 - 2hrs 1.24E-4 1.25E-4 LPZ LPZ 0 - 8 hrs 2.42E-5 2.91 E-5 8 - 24 hrs 1.68E-5 2.03E-5 1 - 4 days 7.55E-6 9.30E-6 4 - 30 days 2.40E-6 3.03E-6