July 23, 1998 MEMORANDUM TO:

File (Original signed by Charles A. Casto)

FROM:

Charles A. Casto, Deputy Director.

Division of Reactor Projects

SUBJECT:

MINUTES OF OCONEE MANAGEMENT OVERSIGHT GROUP (MOG) THIRD MEETING, JULY 1998 In accordance with the memorandum from Luis A. Reyes, dated April 13, 1998, "Oconee Management Oversight Group Charter," a Management Oversight Group (MOG) was assigned for oversight of operations at Oconee. The MOG met at the Region II office first on April 14, 1998. On July 7, 1998. the third meeting was held at the site.

The following personnel attended the-meeting:

Panel Members Charles A. Casto, Region II.

Chairman Herbert N. Berkow, NRR, Vice Chairman David E. LaBarge, NRR, Senior Project Manager Michael A. Scott. Oconee SRI Kerry D. Landis, Engineering Branch Chief, RII Others -

Ronald D. Gibbs, Senior Reactor Inspector Robert E. Carroll. Senior Project Engineer The following summarizes the actions taken by the MOG:

1.

Inspection results for the previous two months were reviewed. Several temporary defense recovery plan initiatives were closed. Open items were discussed (13 closed).

2.

No changes were made to the Oconee Recovery Task Checklist during this meeting; therefore, a revised list will not be published.

3. A discussion of the inspection schedule highlighted the need to control the number of inspectors on-site in order to minimize impact on the licensee. Although some inspections must occur at certain times, we should be conscious of overloading the licensee.
4.

Some changes to the issues checklist were made (Attachment). A proposal was adopted to modify the checklist by numbering the issues. Open items associated with recovery plan issues would be referenced to the main item in the recovery checklist for ease of reference.

9901210090 980723 PDR ADOCK 05000269 P

PDR

Files 2

5.

An action item was assigned to Mr. Landis to clarify the status of two line items. During the upcoming meeting, Kerry will brief the group on the status of SQUG and containment coatings.

Docket Nos.:

50-269, -270, -287 License Nos.: DPR-38, -47, -55

Attachment:

Oconee Recovery Plan Issues Checklist Distribution:

Docket File w/att L. Reyes, RA/RII w/att C. Casto, DRP/RII w/att H. Berkow, NRR/PD w/att D. LaBarge, NRR/SPM w/att M. Tschiltz, EDO w/att B. Boger, NRR w/att M. Scott, SRI w/att K. Landis, DRS/RII w/att C. Ogle, DRP/RII w/att R. Carroll, DRP/RII w/att PUBLIC OFFICE RII:DRP RII:DRP U

RII:NRR SIGNATURE 0IAND 7Ef WWKE D MLET, KMPD\\MN DSWME CUPYk I

-(L S

YES YESYEYS OFFYCIL RECRDCP DOCUMENT NAME:

P:\\MINUTES.003

OCONEE RECOVERY PLAN ISSUES CHECKLIST Area Action j NRC Lead Licensee JTNRC Inspection/Action NRC Status (Results/IR/Date)

Status LICENSEE RECOVERY PLAN ACTIONS Design Basis

[DB1]

HPI System Review Landis Complete 7/6-10/98 Moore, Open Thomas

[DB2]

SITA HPI/LPI System Review Landis Projected 98-06 (Pending)

Open completion 12/11/97 12/31/98

[DB3]

Oconee Safety Related Landis Projected 7/6-10/98 Moore, Open Designation (OSRDC)

(NRR-Any completion-Thomas licensing 5/15/98-1/99 8/24-9/4/98 Schin.

issues)

Thomas

[DB4]

Resolve ECCW Suction Supply Landis Projected 98-05 (Excellent)

Open to LPSW (OSW) completion 6/1/98-11/2-6/98 Kellogg, 5/1/99 Thomas

[DB5]

USFAR Review Project Landis Projected 11/16-20/98 Schin, Open completion-Thomas 12/31/98 6/30/99 1

.ATTACHMENT

[DB6]

SQUG Outlier Resolution Landis Projected 8/24-28/98 Chou Open Review completion 6/30/98-2002

[DB7]

Emergency Power Project Christnot 5/1/99 98-11 (Proposed)

Open

[DB8]

GL 96-06 Review (non-Landis Projected 7/6-10/98 Moore Open licensing issues) completion-10/5-9/98 Moore 7/10/98 U3EOC18

[DB9]

EFW SSEI Landis Projected 8/24-9/4/98 Moore Open completion 8/7/98 and 30 days after report entered into PIP

[DB10]

Configuration Management Landis Projected 7/27-31/98 Schin, Open Project completion Thomas 12/31/98 9/21-25/98 Schin, Thomas System Equipment

[SE1]

Material Condition Upgrade Scott 98-06 (Pending)

Open 98-07 (Proposed)

[SE2]

Control Rod Drive Mechanism Billings U3EOC19 98-06 (Pending)

Open Replacement U3EOC19 (Proposed)

[SE3]

Top Equipment Problem.

Freeman Ongoing 98-09 (Proposed)

Open Resolution Process (TEPR) 2 ATTACHMENT

[SE4]

System Team'Development Landis Projected 10/5-9/98 Moore, Open completion-Thomas 1/6/98 6/15/98

[SE5]

Fluid Leak Management Freeman Projected 98-08 (Proposed)

Open Program completion 11/1/98

[SE61 Temporary Modifications Landis Projected 7/27-31/98 Schin, Open completion Thomas 4/15/99 9/21-25/98 Schin.

Thomas

[SE7]

CRIP Management and Billings 98-07 (Proposed)

Open Reduction

[SE8]

Inservice Inspection Program Fredrickson 98-05 HPI (Adequate)

Open Assessment 98-05 OTSG (Good) 8/17-21/98 Blake 11/2-6/98 Blake

[SE9]

Secondary System Component Landis Projected 7/27-31/98 Schin, Open Reliability completion-Thomas 2/3/98 6/17/98 Human Performance

[P1]

Human Performance Measures Scott 12/31/98 98-06 (Pending)

Open and Organization Direction 98-09 (Proposed)

(ORP)

[P2]

Maintenance Procedures Christnot 98-07 (Proposed)

Open 98-08 (Proposed) 3 ATTACHMENT

Self Assessment

[SA1]

PIP Activity Backlog Landis 12/31/98 8/24-9/4/98 Schin, Open Thomas 11/30-12/4/98 Moore, Schin, Thomas

[SA2]

PIP Quality Improvements Landis 7/31/98 8/24-9/4/98 Schin, Open Thomas 11/30-12/4/98 Moore, Schin, Thomas

[SA3]

Manager Observations and Landis 12/31/98 8/24-9/4/98 Schin, Open Group Self Assessment Thomas 11/30-12/4/98 Schin, Thomas

[SA4]

Inplant Review/Job Billings 98-08 (Proposed)

Open Observation Program Operational Focus

[OFl]

Root Cause Analysis and Landis 12/31/98 8/24-9/4/98 Schin, Open Corrective Action Thomas 11/30-12/4/98 Moore, Schin, Thomas, Rogers

[0F2]

Emergency Operating Landis Projected Open Procedures completion 1/1/99

[0F3]

Response to Operational Billings Projected 98-08 (Proposed)

Open Concerns completion 10/01/98 4

ATTACHMENT

[OF4]

Risk Assessment Freeman Projected 98-09 (Proposed)

Open completion 10/01/98

[0F5]

Work Backlog Management Fredrickson Projected Gibbs Open completion 9/1/98

[0F6]

Outage Readiness Fredrickson Projected Gibbs Open completion 8/30/98 Temporary Defence

[TD1]

A.1 Management oversight Freeman Complete 98-06 (Pending)

Closed observation

[TD2]

A.2 Management oversight Freeman.

Complete 98-06 (Pending)

Closed during startup/shutdown

[TD3]

A.3 Inventory Monitoring Freeman Complete 98-06 (Pending)

Closed Enhancements

[TD4]

B. Eng/Ops/Maint Interface Landis/

Complete 10/5-9/98 Gibbs, Open Fredrickson Moore

[TD5]

C. Improved Trouble Shooting Freeman Complete 98-08 (Proposed)

Open

[TD6]

E. Post Maint/Mod Testing Landis/

Projected 10/5-9/98 Gibbs, Open Fredrickson completion Moore 8 /30 /98

[TD7]

F. Chemistry/Ops Interface Christnot Complete 98-06 (Pending)

Open 5

ATTACHMENT

NRC AREAS OF CONCERN

[NRC1]

Procedural Scott 98-09 (Proposed)

Open Human Controls/Adequacy/Compliance Performance

[NRC2]

Safety Assessment Quality Christnot 98-06 (Pending)

Open Problem ID Verification (including OEF) 98-08 (Proposed) and Resolution

[NRC3]

CREV SSEI Landis 98-03 (Poor)

Open Design 11/16-20/98 Moore.

Basis/Tech Schin, Thomas Support 12/14-18/98 Moore, Schin. Thomas

[NRC4]

Emergency Electrical NRR Open Design Distribution System Review Basis/Tech (TAC A0886, A0887, A0888)

Support

[NRC5]

Containment Coatings Landis Open Equipment

[NRC6]

Keowee W Breaker Christnot 98-10 (Proposed)

Open Equipment Mods/Replacement Issues Not Essential for Recovery 98-01 Przr & Letdown welds NRR 98-GO-001 VT-3 exam req NRR 98-GO-002 Bolting torque NRR 6

ATTACHMENT

98-GO-003 Alt to exam of NRR concrete containment Fatique Analysis NRR Operating Experience Program Christnot 98-08 (Proposed)

Open Operational Safeguards Landis Response Evaluation (OSRE)

Severe Accident Management Billings 97-18 Closed Guidelines (SAMGs)

OAC Replacement Project Freeman 98-06 (Pending)

Closed ONS Equipment Aging Project Freeman 98-10 (Proposed)

Open Integrated Control System Freeman 98-06 (Pending)

Closed Replacement I

I I

I_

I Other NRR Actions (Not Essential for Recovery)

SQUG (Outliers monitored NRR under licensee's program)

ITS NRR HPI Amendment NRR CREV (TIA)

Landis Service Water Amendment NRR NRC letter dated Closed 4/24/98 (TAC M99487, M99488, M99489)

MSL Break Detection NRR (BL 80-04) 7 ATTACHMENT

July 23, 1998 MEMORANDUM TO:

File (Original signed by Charles A. Casto)

FROM:

Charles A. Casto, Deputy Director Division of Reactor Projects

SUBJECT:

MINUTES OF OCONEE MANAGEMENT OVERSIGHT GROUP (MOG) THIRD MEETING, JULY 1998 In accordance with the memorandum from Luis A. Reyes, dated April 13, 1998, "Oconee Management Oversight Group Charter," a Management Oversight Group (MOG) was assigned for oversight of operations at Oconee. The MOG met at the Region II office first on April 14, 1998. On July 7, 1998, the third meeting was held at the site.

The following personnel attended the meeting:

Panel Members -

Charles A. Casto, Region II.

Chairman Herbert N. Berkow. NRR, Vice Chairman David E. LaBarge, NRR, Senior Project Manager Michael A. Scott, Oconee SRI Kerry D. Landis. Engineering Branch Chief. RII Others -

Ronald D. Gibbs, Senior Reactor Inspector Robert E. Carroll, Senior Project Engineer The following summarizes the actions taken by the MOG:

1.

Inspection results for the previous two months were reviewed. Several temporary defense recovery plan initiatives were closed. Open items were discussed (13 closed).

2.

No changes were made to the Oconee Recovery Task Checklist during this meeting; therefore, a revised list will not be published.

3. A discussion of the inspection schedule highlighted the need to control the number of inspectors on-site in order to minimize impact on the licensee. Although some inspections must occur at certain times, we should be conscious of overloading the licensee.
4.

Some changes to the issues checklist were made (Attachment). A proposal was adopted to modify the checklist by numbering the issues. Open items associated with recovery plan issues would be referenced to the main item in the recovery checklist for ease of reference.

9901210090 980723 PDR ADOCK 05000269 PDR

Files 2

5.

An action item was assigned to Mr. Landis to clarify the status of two line items. During the upcoming meeting, Kerry will brief the group on the status of SQUG and containment coatings.

Docket Nos.:

50-269, -270, -287 License Nos.: DPR-38, -47, -55

Attachment:

Oconee Recovery Plan Issues Checklist Distribution:

Docket File w/att L. Reyes, RA/RII w/att C. Casto, DRP/RII w/att H. Berkow, NRR/PD w/att D. LaBarge, NRR/SPM w/att

.M.

Tschiltz, EDO w/att B. Boger, NRR w/att M. Scott, SRI w/att K. Landis, DRS/RII w/att C. Ogle, DRP/RII w/att R. Carroll, DRP/RII w/att PUBLIC OFFICE RII:DRP RII:DRP RII:NRR SIGNATURE NAME

COGLE, KLAND DLABARGE

,C Y?

DYUETENA (ES 2\\UYES YES YES YES OFFICIAL REC3RD TDPY DO 0CUMENT NAME:

P:\\MINUTES.003

OCONEE RECOVERY PLAN ISSUES CHECKLIST Area Action NRC Lead Licensee NRC Inspection/Action NRC StatuS (Results/IR/Date)

IStatusi LICENSEE RECOVERY PLAN ACTIONS Design Basis

[DB1]

HPI System Review Landis Complete 7/6-10/98 Moore, Open Thomas

[DB21 SITA HPI/LPI System Review Landis Projected 98-06 (Pending)

Open completion 12/11/97 12/31/98

[DB3]

Oconee Safety Related Landis Projected 7/6-10/98 Moore, Open Designation (OSRDC)

(NRR-Any completion-Thomas licensing 5/15/98-1/99 8/24-9/4/98 Schin.

issues)

Thomas

[DB4]

Resolve ECCW Suction Supply Landis Projected 98-05 (Excellent)

Open to LPSW (OSW) completion 6/1/98-11/2-6/98 Kellogg, 5/1/99 Thomas

[DB5]

USFAR Review Project Landis Projected 11/16-20/98 Schin, Open completion-Thomas 12/31/98 6/30/99 I

ATTACHMENT

[DB6]

SQUG Outlier Resolution Landis Projected 8/24-28/98 Chou Open Review completion 6/30/98-2002

[DB7]

Emergency Power Project Christnot 5/1/99 98-11 (Proposed)

Open

[DB8]

GL 96-06 Review (non-Landis Projected 7/6-10/98 Moore Open licensing issues) completion-10/5-9/98 Moore 7/10/98 U3EOC18

[DB9]

EFW SSEI Landis Projected 8/24-9/4/98 Moore Open completion 8/7/98 and 30 days after report entered into PIP

[DB10]

Configuration Management Landis Projected 7/27-31/98 Schin, Open Project completion Thomas 12/31/98 9/21-25/98 Schin, Thomas System Equipment

[SE1]

Material Condition Upgrade Scott 98-06 (Pending)

Open 98-07 (Proposed)

[SE2]

Control Rod Drive Mechanism Billings U3EOC19 98-06 (Pending)

Open Replacement U3EOC19 (Proposed)

[SE3]

Top Equipment Problem Freeman Ongoing 98-09 (Proposed)

Open Resolution Process (TEPR) 2

-ATTACHMENT

[SE4]

System Team Development Landis Projected 10/5-9/98 Moore, Open completion-Thomas 1/6/98 6/15/98

[SE5]

Fluid Leak Management Freeman Projected 98-08 (Proposed)

Open Program completion 11/1/98

[SE6]

Temporary Modifications Landis Projected 7/27-31/98 Schin, Open completion Thomas 4/15/99 9/21-25/98 Schin.

Thomas

[SE7]

CRIP Management and Billings 98-07 (Proposed)

Open Reduction

[SE8]

Inservice Inspection Program Fredrickson 98-05 HPI (Adequate)

Open Assessment 98-05 OTSG (Good) 8/17-21/98 Blake 11/2-6/98 Blake

[SE9]

Secondary System Component Landis Projected 7/27-31/98 Schin, Open Reliability completion-Thomas 2/3/98 6/17/98 Human Performance

[P1]

Human Performance Measures Scott 12/31/98 98-06 (Pending)

Open and Organization Direction 98-09 (Proposed)

(ORP)

[P2]

Maintenance Procedures Christnot 98-07 (Proposed)

Open 98-08 (Proposed) 3 ATTACHMENT

Self Assessment

[SA1]

PIP Activity Backlog Landis 12/31/98 8/24-9/4/98 Schin, Open Thomas 11/30-12/4/98 Moore, Schin, Thomas

[SA2]

PIP Quality Improvements Landis 7/31/98 8/24-9/4/98 Schin, Open Thomas 11/30-12/4/98 Moore, Schin, Thomas

[SA3]

Manager Observations and Landis 12/31/98 8/24-9/4/98 Schin,.

Open Group Self Assessment Thomas 11/30-12/4/98 Schin, Thomas

[SA4]

Inplant Review/Job Billings 98-08 (Proposed)

Open Observation Program Operational Focus

[OF1]

Root Cause Analysis and Landis 12/31/98 8/24-9/4/98 Schin.

Open Corrective Action Thomas 11/30-12/4/98 Moore, Schin, Thomas, Rogers

[0F2]

Emergency Operating Landis Projected Open Procedures completion 1/1/99

[0F3]

Response to Operational Billings Projected 98-08 (Proposed)

Open Concerns completion 10/01/98 4

ATTACHMENT

[0F4]

Risk Assessment Freeman Projected 98-09 (Proposed)

Open completion 10/01/98

[OF5]

Work Backlog Management Fredrickson Projected Gibbs Open completion 9/1/98

[0F6]

Outage Readiness Fredrickson Projected Gibbs Open completion 8/30/98 Temporary Defence

[TD1]

A.1 Management oversight Freeman Complete 98-06 (Pending)

Closed observation

[TD2]

A.2 Management oversight Freeman Complete 98-06 (Pending)

Closed during startup/shutdown

[TD3]

A.3 Inventory Monitoring Freeman Complete 98-06 (Pending)

Closed Enhancements

[TD4]

B. Eng/Ops/Maint Interface Landis/

Complete 10/5-9/98 Gibbs, Open Fredrickson Moore

[TD5]

C. Improved Trouble Shooting Freeman.

Complete 98-08 (Proposed)

Open

[TD6]

E. Post Maint/Mod Testing Landis/

Projected 10/5-9/98 Gibbs, Open Fredrickson completion Moore 8/30/98

[TD7]

F. Chemistry/Ops Interface Christnot Complete 98-06 (Pending)

Open 5

ATTACHMENT

NRC AREAS OF CONCERN

[NRC1]

Procedural Scott 98-09 (Proposed)

Open Human Controls/Adequacy/Compliance Performance

[NRC2]

Safety Assessment Quality Christnot 98-06 (Pending)

Open Problem ID Verification (including OEF) 98-08 (Proposed) and Resolution

[NRC3]

CREV SSEI Landis 98-03 (Poor)

Open Design 11/16-20/98 Moore, Basis/Tech Schin, Thomas Support 12/14-18/98 Moore, Schin. Thomas

[NRC4]

Emergency Electrical NRR Open Design Distribution System Review Basis/Tech (TAC A0886, A0887, A0888)

Support

[NRC5]

Containment Coatings Landis Open Equipment

[NRC6]

Keowee W Breaker Christnot 98-10 (Proposed)

Open Equipment Mods/Replacement Issues Not Essential for Recovery 98-01 Przr & Letdown welds NRR 98-GO-001 VT-3 exam req NRR 98-GO-002 Bolting torque NRR 6

ATTACHMENT

98-GO-003 Alt to exam of NRR concrete containment Fatique Analysis NRR Operating Experience Program Christnot 98-08 (Proposed)

Open Operational Safeguards Landis Response Evaluation (OSRE)

Severe Accident Management Billings 97-18 Closed Guidelines (SAMGs)

OAC Replacement Project Freeman 98-06 (Pending)

Closed ONS Equipment Aging Project Freeman 98-10 (Proposed)

Open Integrated Control System Freeman 98-06 (Pending)

Closed Replacement Other NRR Actions (Not Essential for Recovery)

SQUG (Outliers monitored NRR under licensee's program)

ITS NRR HPI Amendment NRR CREV (TIA)

Landis Service Water Amendment NRR NRC letter dated Closed 4/24/98 (TAC M99487, M99488, M99489)

MSL Break Detection NRR (BL 80-04) 7 ATTACHMENT