tf REG(,u UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20556 January 4, 1993 Docket Nos. 50-269, 50-270, 50-287, 50-289, 50-302, 50-313, 50-346 FACILITY: BABCOCK & WILCOX OWNERS GROUP
SUBJECT:
SUMMARY
OF MEETING WITH BABCOCK & WILCOX OWNERS GROUP CONCERNING THEIR GENERIC LICENSE RENEWAL PROGRAM Representatives of the Babcock & Wilcox Owners Group (BWOG) met with the Nuclear Regulatory Commission (NRC) staff in Lynchburg, Virginia on Tuesday, November 24, 1992. The purpose of the meeting was to discuss the BWOG preliminary program plan for their generic license renewal program. Enclosed is a list of meeting attendees.
The meeting was in two parts. The first part of the meeting was open to the public and the second part of the meeting was closed to the public (only representatives from the NRC and from the BWOG were in attendance during the second part). The second part of the meeting was closed at the request of BWOG because the discussions included information that BWOG considered proprietary.
The first part of the meeting included presentations by BWOG and discussions on the following issues:
- 1. BWOG Generic License Renewal Program philosophy.
- 2. Participants in the Generic License Renewal Program. BWOG anticipates having EPRI, NUMARC, and the U.S. Department of Energy involved in this activity. The utilities involved in this activity are Duke Power, Entergy Operations, Florida Power, GPU Nuclear, and Toledo Edison.
- 3. BWOG's Program Goal; which is to establish a license renewal process that will serve the BWOG, be acceptable to the NRC, and be a model that the industry can use.
- 4. The Generic License Renewal Program Concept.
- 5. BWOG's intent to submit technical reports in 1993 that will discuss major issues.
The first part of the meeting ended with the BWOG indicating their intent and desire to frequently interact with the NRC to ensure adequate discussion and resolution of technical and process issues.
9301080229 930104 PDR ADOCK 05000269 P
January 4, 1993
-2 The information presented and discussed during the second part of the meeting is not discussed in this meeting summary due to the proprietary nature of the information. The information was for the general information of the NRC and is not intended to be used as a basis for any official actions by the NRC.
Original signed by:
Steven A. Reynolds, Senior Project Manager License Renewal and Environmental Review Project Directorate Associate Directorate for Advanced Reactors and License Renewal Office of Nuclear Reactor Regulation
Enclosure:
Attendees List cc w/enclosure:
See next pages DISTRIBUTION:
Central File PDR PDLR R/F TMurley/FMiraglia, 12G18 JPartlow, 12G18 Wiravers, IIH21 FAkstulewicz, 1IF23 SReynolds, 11F23 LLuther, 11F23 OGC EJordan, MNBB3701 NRC Participants ACRS (10)
DCrutchfield, 11H21 PTKuo, 11F23 DISTRIBUTION: (via electronic mail)
HSilver JHopkins JCraig LWiens RHernan GGrant GMitchell VMcCree LPlisco SDroggitis EReis RBevan JVora PDLR Staff PDLR:LA 1 /
PDLR:SPMv-PDLR:SC). tL PDLR4-NRR: A LLuther a,
SReynold FAkstulewicV SNewerr WT er 12/D M /9 1
/
1//93 0M/E /93
-/93 DOCUMENT ME:
B&WMEET
LICENSE RENEWAL MEETING WITH B&W OWNERS GROUP GENERIC LICENSE RENEWAL INITIATIVE NOVEMBER 24, 1992 ATTENDANCE LIST NAME TITLE & AFFILIATION Steven A. Reynolds Sr. Project Manager, PDLR/NRR John W. Craig Director, PDLR/NRR Francis M. Akstulewicz Section Chief, PDLR/NRR Jit Vora Section Leader, RES Jocelyn Mitchell Office of EDO, NRC Tony L. McConnell Program Director, BWOG Debbie Staudinger Program Coordinator, BWOG William R. Gray Program Manager, BWNS Jim Taylor Licensing Manager, BWNS Bob Borsum BWNT Gregory D. Robinson Project Engineer, Duke Donald N. Fultonberg Project Engineer, GPUN Daniel W. Fouts Entergy Operations, Inc.
William T. O'Connor Toledo Edison Co.
Vincent R. Roppel Project Engineer, Florida Power Corp.
Mark A. Rinkel Project Engineer, BWNS Nigel Goulding Supervisor, BWNS Jonathan A. Coburn Supervisory Engineer, BWNS Timothy G. Stack Systems Engineer, BWNS John Concklin BWNS Robert I. Lutz I&C/Electrical L.E., BWNS Fred R. Burke Plant Life Mgmt, BWNS Scott A. Wingate Nuclear Engineer, HNUS John Giddens EPRI LCM, Southern Nuclear Doug Walters NUMARC ENCLOSeURE
cc:
Tony L. McConnell William R. Gray Program Director Program Manager Generic License Renewal Program Generic License Renewal Program 3315 Old Forest Road B&W Nuclear Services P.O. Box 10935 3315 Old Forest Road Lynchburg, Virginia 24506-0935 P.O. Box 10935 Lynchburg, Virginia 24506-0935 Debbie Staudinger Program Coordinator Robert B. Borsum Generic License Renewal Program Licensing Engineer 3315 Old Forest Road B&W Nuclear Technologies P.O. Box 10935 1700 Rockville Pike Lynchburg, Virginia 24506-0935 Suite 525 Rockville, Maryland 20852 Mr. Jerry W. Yelverton Ms. Greta Dicus, Director Vice President Operations Support Division of Radiation Control Entergy Operations, Inc.
and Emergency Management Route 3, Box 137G Arkansas Department of Health Russellville, Arkansas 72801 4815 West Markham Street Little Rock, Arkansas 72205-3867 Mr. Donald C. Hintz, President and Chief Executive Officer Mr. John R. McGaha Entergy Operations, Inc.
Vice President, Operations Support P.O. Box 31995 Entergy Operations, Inc.
Jackson, Mississippi 39286 P.O. Box 31995 Jackson, Mississippi 39286 Mr. R. A. Fenech General Manager, Plant Operations Mr. Robert B. McGehee Entergy Operations, Inc.
Wise, Carter, Child & Caraway 39205 Route 3 Box 137G P. 0. Box 651 Russellville, Arkansas 72801 Jackson, Mississippi 39286 Mr. Nicholas S. Reynolds Mr. James J. Fisicaro Winston & Strawn Director, Licensing 1400 L Street, N.W.
Entergy Operations, Inc.
Washington, D.C. 20005-3502 Route 3, Box 137G Russellville, Arkansas 72801 Senior Resident Inspector U.S. Nuclear Regulatory Commission Admiral Kinnaird R. McKee, USN (Ret) 1 Nuclear Plant Road 214 South Morris Street Russellville, Arkansas 72801 Oxford, Maryland 21654 Regional Administrator, Region IV Mr. Charles B. Brinkman, Manager U.S. Nuclear Regulatory Commission Washington Nuclear Operations 611 Ryan Plaza Drive, Suite 1000 Combustion Engineering, Inc.
Arlington, Texas 76011 12300 Twinbrook Parkway, Suite 330 Rockville, Maryland 20852 Honorable Joe W. Phillips County Judge of Pope County Pope County Courthouse Russellville, Arkansas 72801
cc:
Mr. Percy M. Beard, Jr.
Attorney General Florida Power Corporation Department of Legal Affairs P.O. Box 219-NA-21 The Capitol Crystal River, Florida 34423-0219 Tallahassee, Florida 32304 Mr. A. H. Stephens State Planning and Development General Counsel Clearinghouse Florida Power Corporation Office of Planning and Budget MAC - A5D Executive Office of the Governor P.O. Box 14042 The Capitol Building St. Petersburg, Florida 33733 Tallahassee, Florida 32301 Mr. P. F. McKee, Director Chairman Nuclear Plant Operations Board of County Commissioners Florida Power Corporation Citrus County P.O. Box 219-NA-2C 110 North Apopka Avenue Crystal River, Florida 32629 Inverness, Florida 32650 Senior Resident Inspector Mr. Rolf C. Widell, Director Crystal River Unit 3 Nuclear Operations Site Support U.S. Nuclear Regulatory Commission Florida Power Corporation 6745 N. Tallahassee Road P.O. Box 219-NA-2I Crystal River, Florida 32629 Crystal River, Florida 32629 Mr. Jacob Daniel Nash Mr. Gary L. Boldt Office of Radiation Control Vice President, Nuclear Production Department of Health and Florida Power Corporation Rehabilitative Services P.O. Box 219-SA-2C 1317 Winewood Blvd.
Crystal River, Florida 32629 Tallahassee, Florida 32399-0700 Administrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301
cc:
Mr. Donald C. Shelton Radiological Health Program Vice President, Nuclear Ohio Department of Health Toledo Edison Company P.O. Box 118 300 Madison Avenue Columbus, Ohio 43266-0149 Toledo, Ohio 43652 Attorney General Mary E. O'Reilly Department of Attorney General Centerior Energy Corporation 30 East Broad Street 300 Madison Avenue Columbus, Ohio 43215 Toledo, Ohio 43652 Mr. James W. Harris, Director Mr. Robert W. Schrauder Division of Power Generation Manager, Nuclear Licensing Ohio Department of Industrial Toledo Edison Company Regulations 300 Madison Avenue P.O. Box 825 Toledo, Ohio 43652 Columbus, Ohio 43216 Gerald Charnoff, Esq.
Ohio Environmental Protection Agency Shaw, Pittman, Potts DERR--Compliance Unit and Trowbridge ATTN:
Zack A. Clayton 2300 N Street, N.W.
P.O. Box 1049 Washington, D.C. 20037 Columbus, Ohio 43266-0149 Regional Administrator, Region President, Board of Ottawa U.S. Nuclear Regulatory Commission County Commissioners 799 Roosevelt Road Port Clinton, Ohio 43452 Glen Ellyn, Illinois 60137 State of Ohio Resident Inspector Public Utilities Commission U.S. Nuclear Regulatory Commission 180 East Broad Street 5503 N. State Route 2 Columbus, Ohio 43266-0573 Oak Harbor, Ohio 43449 Mr. James R. Williams Mr. Murray R. Edelman State Liaison to the NRC Executive Vice President Adjutant General's Department Power Generation Office of Emergency Management Centerior Service Company Agency 6200 Oak Tree Boulevard 2825 West Granville Road Independence, Ohio 44101 Columbus, Ohio 43235-2712
cc:
Mr. J. W. Hampton Mr. A. V. Carr, Esquire Vice President Duke Power Company Duke Power Company 422 South Church Street P.O. Box 1439 Charlotte, North Carolina 28242-0001 Seneca, South Carolina 29679 Office of Intergovernmental Relations J. Michael McGarry, III, Esquire 116 West Jones Street Winston and Strawn Raleigh, North Carolina 27603 1400 L Street, N.W.
Washington, DC 20005 Mr. M. E. Patrick Compl iance Manager, LIS Duke Power Company NUS Corporation Oconee Nuclear Site 2650 McCormick Drive, 3rd Floor P.O. Box 1439 Clearwater, Florida 34619-1035 Seneca, South Carolina 29679 Senior Resident Inspector Mr. Alan R. Herdt, Chief U.S. Nuclear Regulatory Commission Project Branch #3 Route 2, Box 610 U.S. Nuclear Regulatory Commission Seneca, South Carolina 29678 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Ms. Karen E. Long 101 Marietta Street, NW, Suite 2900 Assistant Attorney General Atlanta, Georgia 30323 North Carolina Department of Justice P.O. Box 629 Mr. Heyward G. Shealy, Chief Raleigh, North Carolina 27602 Bureau of Radiological Health South Carolina Department of Health Mr. R. L. Gill, Jr.
and Environmental Control Licensing 2600 Bull Street Duke Power Company Columbia, South Carolina 29201 P.O. Box 1006 Charlotte, North Carolina 28201-1006 County Supervisor of Oconee County Walhalla, South Carolina 29621
cc:
Mr. T. Gary Broughton Kenneth E. Witmer, Chairman Vice President and Director, TMI-1 Board of Supervisors GPU Nuclear Corporation of Londonderry Township P.O. Box 480 25 Roslyn Road Middletown, Pennsylvania 17057 Elizabeth, Pennsylvania 17022 Mr. Michael Ross Francis 1. Young 0&M Director, TMI-1 Senior Resident Inspector (TMI-1)
GPU Nuclear Corporation U.S.N.R.C.
P.O. Box 480 P.O. Box 311 Middletown, Pennsylvania 17057 Middletown, Pennsylvania 17057 Mr. Michael Laggart Regional Administrator, Region I Manager, Licensing U.S. Nuclear Regulatory Commission GPU Nuclear Corporation 475 Allendale Road 100 Interpace Parkway King of Prussia, Pennsylvania 19406 Parsippany, New Jersey 07054 Governor's Office of State Planning Mr. C. W. Smyth and Development TMI-1 Licensing Manager ATTN:
Coordinator, Pennsylvania GPU Nuclear Corporation State Clearinghouse P.O. Box 480 P.O. Box 1323 Middletown, Pennsylvania 17057 Harrisburg, Pennsylvania 17120 Earnest L. Blake, Jr., Esq.
Thomas M. Gerusky, Director Shaw, Pittman, Potts & Trowbridge Bureau of Radiation Protection 2300 N Street, NW Pennsylvania Department of Washington, DC 20037 Environmental Resources P.O. Box 2063 Ms. Sally S. Klein, Chairperson Harrisburg, Pennsylvania 17120 Dauphin County Commissioner Dauphin County Courthouse Front and Market Streets Harrisburg, Pennsylvania 17120