NRC Comments on Draft FAC-Developed Operating Exam (Folder 2)
ML15244A311
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 07/27/2015
From:
Susquehanna
To: Todd Fish
Operations Branch I
Shared Package
ML15063A453 List:
References
TAC U01916
Download: ML15244A311 (2)


Text

TALEN Memorandum To:

Todd Fish {USN RC Chief Examiner)

From:

Greg van den Berg (Supervisor SSES Exam Group acting)

Date:

08/11/2015 Re:

Generic Summary of Operating Test Revisions in Response to NRC Comments Simulator and Plant JPM Revisions A. No comments B. Add recommended enhancements Add NPO field report, Add Evaluator Cue that, "another operator will perform 'x'... "

Add procedure reference/ steps (cut/paste steps from procedure)

C. Add recommended enhancements Limit scope of JPM to one component Minimize operator actions by providing an Evaluator cue that actions will be performed by another operator Provide marked up procedures Add evaluator cues to address procedure steps Mark step 'x' as critical D. Add a brief summary of N/ Ad procedure steps to Evaluator note E. Add a brief summary of N/ Ad procedure steps F. Add a brief summary of N/Ad procedure steps G. Add a brief summary of N/ Ad procedure steps H. Reverted back to original I.

No comments J.

No comments K.

Replaced JPM 1

Admin JPM Revisions COOl RO. Updated initial conditions COOl SRO. No comments C002 RO. No comments C002 SRO. Updated mark-up handouts EC RO. Clarified Answer Key EC SRO. No comments RC SRO. No comments EP RO. Clarified critical steps on answer key EP SRO. Revised Initial conditions to match scenario conditions Scenario Comments Scenario #1

  • No comments Scenario #2 -
  • Provided a candidate credit for one of the events.
  • Adjusted the initial conditions for one of the events.
  • Corrected a component's identification name.

Scenario #3

  • Corrected a component's identification name
  • Added additional details for crew response to one of the events Scenario #4
  • Revised the initial conditions
  • Replaced the normal evolution in the scenario
  • Changed the order of events in the scenario prior to the major.

August 11, 2015 2