TAC-M84695, NUDOCS 9311300107
Download: ML15239A500 (2)


Text

Docket No.: 50-270 Mr. J. W. Hampton Vice President, Oconee Site Duke Power Company P. 0. Box 1439 Seneca, South Carolina 29679

Dear Mr. Hampton:

SUBJECT:

OCONEE NUCLEAR STATION, UNIT 2 - USE OF CODE CASE N-416 FOR THE SECOND TEN-YEAR INTERVAL INSERVICE INSPECTION (TAC NO. M84695)

By letter dated March 2, 1992, Duke Power Company (licensee) submitted Request for Relief 92-05 requesting to perform a surface examination and an operational pressure test in lieu of the required hydrostatic test for the welds used to replace Valves 2CF-20 and -22.

This request was evaluated and subsequently denied by the NRC in a letter dated June 17, 1992, due to insufficient technical justification. In response, you withdrew Request for Relief 92-05 in a letter dated September 24, 1992, and announced your intention to use Code Case N-416 and defer the Code-required hydrostatic test for the welds used to replace Valves 2CF-20 and -22.

The NRC staff, with technical assistance from its contractor, the Idaho National Engineering Laboratory, has reviewed and evaluated your submittal and supporting information.

The staff has concluded, based on the fact that Code Case N-416 has been approved in Regulatory Guide 1.147, Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 10, and you have stated that all the requirements of Code Case N-416 will be satisfied, the use of Code Case N-416 is acceptable provided: (1) that Code Case N-498 is not invoked, or used concurrently with Code Case N-416, (2) the system hydrostatic test is performed on the repair and replacement areas before the end of the current interval, and (3) you comply with your commitment that all requirements in Code Case N-416 will be satisfied. The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation. This completes our activities under TAC M84695.

Sincerely, LWA&

figlek:, Project Manager Project Directorate 11-3 Division of Reactor Projects -

I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation Report cc w/enclosure: See next page DISTRIBUTION RHermann PDII-3 R/F EMerschoff, RII

'Docket File' L. Weins OGC, 15818 ACRS (10), P-15 NRC & Local PDRs L. Berry SVarga GLainas J. Strosnider T. McLellan 9311300107 931116 PDR ADOCK 05000270 P

' PDR OFF LA:PD2 P

23:PRPE D:PD23:DRPE NAME LBerry 4 ens dt RHerman_

ou m n N

1a /9me O

I /CO 6

/93 5\\LTR Document Name: OCONEE\\0C084695\\LTR

-fi FIL M

'3

Mr. J. W. Hampton Duke Power Company Oconee Nuclear Station cc:

Mr. A. V. Carr, Esquire Mr. N. E. Patrick Duke Power Company Compliance 422 South Church Street Duke Power Company Charlotte, North Carolina 28242-0001 Oconee Nuclear Site P. 0. Box 1439 J. Michael McGarry, III, Esquire Seneca, South Carolina 29679 Winston and Strawn 1400 L Street, NW.

Mr. Alan R. Ierdt, Chief Washington, DC 20005 Project Branch #3 U. S. Nuclear Regulatory Commission Mr. Robert B. Borsum 101 Marietta Street, NW. Suite 2900 Babcock & Wilcox Atlanta, Georgia 30323 Nuclear Power Division Suite 525 Ms. Karen E. Long 1700 Rockville Pike Assistant Attorney General Rockville, Maryland 20852 North Carolina Department of Justice Manager, LIS P. 0. Box 629 NUS Corporation Raleigh, North Carolina 27602 2650 McCormick Drive, 3rd Floor Clearwater, Florida 34619-1035 Mr. G. A. Copp Licensing -

ECO50 Senior Resident Inspector Duke Power Company U. S. Nuclear Regulatory Commission P. 0. Box 1006 Route 2, Box 610 Charlotte, North Carolina 28201-1006 Seneca, South Carolina 29678 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, NW. Suite 2900 Atlanta, Georgia 30323 Max Batavia, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 County Supervisor of Oconee County WaShalla, South Carolina 29621