Forwards Proprietary BAW-1661 P, Mark B2 Demonstration Assemblies in Oconee 1,Cycles 7,8 & 9. Rept Available in Central Files Only.Withholding Per 10CFR2.790 Requested. Nonproprietary Version to Be Submitted by 810430
ML15238B331
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 04/10/1981
From: Taylor J
BABCOCK & WILCOX CO.
To: Stolz J
NRC
Shared Package
ML15238B332 List:
References
NUDOCS 8104230207
Download: ML15238B331 (10)


Text

REGULAWORY INFORMA;ION DISTRIBUTI(SYSTEMA(RIDS)

ACCESSION NBR:8104230207 DOC.DATE: 81/04/10 NOTARIZED: YES DOCKET #

FACIL:50-269 Oconee Nuclear Station, Unit to Duke Power Co,.

05000269 AUTHNAME AUTHOR AFFILIATION TAYLOR,J.H.

Sabcock & Wilcox Co.

RECIP.NAME RECIPIENT AFFILIATION STOLZJ.

Office of Nuclear Reactor Regulation, Director:

SUBJECT:

Forwards proprietary BAW*1661 P, "Mark B2 Demonstration Assemblies in Oconee 1,Cycles 7,8 & 9." Withhold per 10CFR2,790 requestedAffidavit encl.Nonproprietary version to be submitted by 810430.

_C

&'47 4-' ygr 4tA"'

DISTRIBUTION CODE: PA01S COPIES RECEIVED:LTR.1 ENCLd Se TITLE: Proprietary Review Distribution -

OL Stage NOTES:AEODOrnstein:1icc.

05000269 RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAMEi LTTR FNL ID CODE/NAME LTTR E."

ACTION:

ORB #

02 7

7 INTERNAL: I&E#/p-// 09 2

N 1

0 OELD 1

0ILE1 I

EXTERNAL: ACRS

//

l 1 19 16 LPDR 1

NSIC 1

c~<s 0 \\ H. S

\\

I CBC APR 2 199, 0

TOTAL NUMBER OF COPIES REQjUIRED: LTTR 31 ENCL

Babcock & Wilcox Nuclear Power Generation Division a McDermott company 3315 Old Forest Road P.O. Box 1260 Lynchburg, Virginia 24505 (804) 384-5111 April 10, 1981 Mr. John Stolz, Chief LWR Branch, Division of Project Management AR2218 Office of Nuclear Reactor Regulation C

VI M 7SgWL,4oaW U. S. Nuclear Regulatory Commission

,1 Washington, DC 20555

Dear Mr. Stolz:

Enclosed are 60 copies of Babcock & Wilcox report BAW-1661 P, "Mark BZ Demonstration Assemblies in Oconee 1, Cycles 7, 8, and 9."

Babcock and Wilcox requests in accordance with 10 CFR 2.79 that this report be considered proprietary. The reason for this classification is given in the attached affidavit. We will be submitting a non-proprietary version of the report by the end of the month.

If you have any questions, please call Mr. C. F. McPhatter on Extension 2401.

V truly yours, J. H. Taylor Manager, Licensing JHT/fw

?Ao/

cc:

Mr. R. B. Borsum -

B&W Bethesda Office 810.42300%

Babcock&Wilcox AFFIDAVIT OF JAMES H. TAYLOR A. My name is James H. Taylor.

I am Manager of Licensing in the Nuclear Power Generation Division of Babcock & Wilcox, and as such I am authorized to execute this Affidavit.

B. I am familiar with the criteria applied by Babcock & Wilcox to de termine whether certain information of Babcock & Wilcox is proprietary and I am familiar with the procedures established within Babcock & Wilcox, particularly the Nuclear Power Generation Division (NPGD), to ensure the proper application of these criteria.

C. In determining whether a Babcock & Wilcox document is to be classi fied as proprietary information, an initial determination is made by the unit manager who is responsible for originating the document as to whether it falls within the criteria set forth in Paragraph D hereof.

If the information falls within any one of these criteria, it is classified as proprietary by the originating unit manager.

This initial determination is reviewed by the cognizant section manager. If the document is designated as proprietary, it is re viewed again by Licensing personnel and other management within NPGD as designated by the Manager of Licensing to assure that the regulatory requirements of 10 CFR Section 2.790 are met.

D. The following information is provided to demonstrate that the pro visions of 10 CFR Section 2.790 of the Commission's regulations have been considered:

(i) The information has been held in confidence by the Babcock &

Wilcox Company.

Copies of the document are clearly identified as proprietary. In addition, whenever Babcock & Wilcox transmits theinformation to a customer, customer's agent, potential customer or regulatory agency, the transmittal re quests the recipient to hold the information as proprietary.

Also, in order to strictly limit any potential or actual customer's use of proprietary information, the following

Babcock&Wilcox AFFIDAVIT OF JAMES H. TAYLOR (Cont'd) provision is included in all proposals submitted by Babcock

& Wilcox, and an applicable version of the proprietary provision is included in all of Babcock & Wilcox's contracts:

"Purchaser may retain Company's Proposal for use in connection with any contract resulting therefrom, and, for that purpose, make such copies thereof as may be necessary.

Any proprietary information concerning Company's or its Suppliers' products or manufacturing processes which is so designated by Company or its Suppliers and disclosed to Purchaser incident to the performance of such contract shall remain the property of Company or its Suppliers and is disclosed in confi dence, and Purchaser shall not publish or otherwise disclose it to others without the written approval of Company, and no rights, implied or otherwise, are granted to produce or have produced any products or to practice or cause to be practiced any manufacturing processes covered thereby.

Notwithstanding the above, Purchaser may provide the NRC or any other regulatory agency with any such pro prietary information as the NRC or such other agency may require; provided, however, that Purchaser shall first give Company written notice of such proposed disclosure and Company shall have the right to amend such proprietary information so as to make it non-pro prietary.

In the event that Company cannot amend such proprietary information, Purchaser shall, prior to disclosing such information, use its best efforts to obtaina commitment from NRC or such other agency to have such information withheld from public inspection.

(2)

Babcock&Wilcox AFFIDAVIT OF JAMES H. TAYLOR (Cont'd)

Company shall be given the right to participate in pursuit of such confidential treatment."

(ii) The following criteria are customarily applied by Babcock &

Wilcox in a rational decision process to determine whether the information should be classified as proprietary.

Information may be classified as proprietary if one or more of the following criteria are met.

a. Information reveals cost or price information, commercial strategies, production capabilities, or budget levels of Babcock & Wilcox, its customers or suppliers.
b. The information reveals data or material concerning Babcock

& Wilcox research or development plans or programs of present or potential competitive advantage to Babcock &

Wilcox.

c. The use of the information by a competitor would decrease his expenditures, in time or resources, in designing, producing or marketing a similar product.
d. The information consists of test data or other similar data concerning a process, method or component, the application or which results in a competitive advantage to Babcock &

Wilcox.

e. The information reveals special aspects of a process, method, component or the like, the exclusive use of which results in a competitive advantage to Babcock & Wilcox.
f. The information contains ideas for which patent protection may be sought.

(3)

Babcock&Wilcox AFFIDAVIT OF JAMES H. TAYLOR (Cont'd)

The document(s) listed on Exhibit "A", which is attached hereto and made a part hereof, has been evaluated in accordance with normal Babcock & Wilcox procedures with respect to classification and has been found to contain information which falls within one or more of the criteria enumerated above.

Exhibit "B", which is attached hereto and made a part hereof, specifically identifies the criteria applicable to the document(s) listed in Exhibit "A".

(iii) The document(s) listed in Exhibit "A", which has been made avail able to the United States Nuclear Regulatory Commission was made available in confidence with a request that the document(s) and the information contained therein be withheld from public disclosure.

(iv) The information is not available in the open literature and to the best of our knowledge is not known by Combustion Engineering, EXXON, General Electric, Westinghouse or other current or potential domestic or foreign competitors of B&W.

(v) Specific information with regard to whether public disclosure of the information is likely to cause harm to the competitive position of Babcock & Wilcox, taking into account the value of the information to Babcock & Wilcox; the amount of effort or money expended by Babcock & Wilcox developing the information; and the ease or difficulty with which the information could be properly duplicated by others is given in Exhibit "B".

E. I have personally reviewed the document(s) listed on Exhibit "A" and have found that it is considered proprietary by Babcock & Wilcox because it contains information which falls within one or more of the criteria enumerated in Paragraph D, and it is information which is customarily held in confidence and protected as proprietary in formation by Babcock & Wilcox.

This report comprises.information utilized by Babcock & Wilcox in its business which afford Babcock

& Wilcox an opportunity to obtain a competitive advantage over (4)

Babcock&Wilcox those who may wish to know or use the information contained in the document(s).

SJAMES H. TAYR State of Virginia) )

SS.

Lynchburg City of Lynchburg)

James H. Taylor, being duly sworn, on his oath deposes and says that he is the person who subscribed his name to the foregoing state ment, and that the matters and facts set forth in the statement are true.

JAMES H. TAYLO Subscribedjnd sworn before-me this

/4 day of 1981.

Notary Public in and or the City of Lynchburg, State of Virginia My Commission Expires c, /9'/

(5)

Babcock&Wilcox EXHIBIT "A" Proprietary Document BAW-1661 P, Mark BZ Demonstration Assemblies in Oconee 1, Cycles 7, 8, and 9.

Babcock&Wilcox Exhibit "B" Identification of proprietary information deleted for this report Section Page Description Applicable Criteria 2

3 Spacer Grid Comparison Figure C

4 7

Changes in Form Loss Coefficients C

5 9

Change in Form Loss Coefficient C

9 OCCET NO. 5O -026 e DATE:

NOTE TO NRC AND/OR LOCAL PUBLIC 0OCUMENT ROOMS The following item submitted with letter dated------

from

---.is being withheld from public disclosure in accordance with Section 2.790.

PROPRIETARY INFORMATION

  • ct4*ek D

,4sx~wseA Distribution Services Branch