ML15237A335

From kanterella
Jump to navigation Jump to search
Attachment 3 - A.15-02-023 Supplemental Testimony of John Geesman
ML15237A335
Person / Time
Site: Diablo Canyon  
Issue date: 08/21/2015
From:
Alliance for Nuclear Responsibility
To:
Japan Lessons-Learned Division
DiFrancesco N, NRR/JLD, 415-115
Shared Package
ML15237A311 List:
References
A.15-02-023 A4NR-3
Download: ML15237A335 (20)


Text

Case No: A.15-02-023 Exhibit No: A4NR-3 Witness: John Geesman Application of Pacific Gas and Electric

)

Company for Compliance Review of Utility

)

Owned Generation Operations, Electric Energy

)

Resource Recovery Account Entries, Contract

)

Application 15-02-023 Administration, Economic Dispatch of Electric

)

(Filed February 27, 2015)

Resources, Utility Retained Generation Fuel

)

Procurement, and Other Activities for the Period

)

January 1 through December 31, 2014.

)

(U 39 E)

)

__________________________________________)

SUPPLEMENTAL PREPARED TESTIMONY OF JOHN GEESMAN ON BEHALF OF THE ALLIANCE FOR NUCLEAR RESPONSIBILITY BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA August 21, 2015

1 QO1: What is the purpose of your Supplemental Testimony?

A01:

A4NR agreed with PG&E that it would provide a specific ratemaking recommendation in evidence after reviewing additional data responses from PG&E that were received after the July 14, 2015 submittal of its Prepared Testimony. This Supplemental Testimony provides that recommendation and reflects upon those data responses.

Q02:

What is A4NRs ratemaking recommendation?

A02:

A4NR recommends that the Commission disallow recovery of the $4.56 million recorded in the DCSSBA as costs incurred in 2014 for the AB 1632 Seismic Studies. PG&Es refusal to interact with the IPRP as required by D.12-09-008 and D.10-08-003, as well as its failure to submit to IPRP review prior to publishing its final report, prevent the Commission from finding that these costs were reasonably incurred. A4NR also recommends disallowance of the $0.90 million recorded in the DCSSBA as costs incurred in 2014 for Project Management of the Long-Term Seismic Program. PG&Es failure to provide for timely IPRP review of the AB 1632 Seismic Studies, and obtain the IPRPs assurance that the AB 1632 Seismic Studies were properly incorporated into PG&Es SSHAC report as intended by D.12-09-008, prevents the Commission from finding that these Project Management costs were reasonably incurred.

Q03:

What role did PG&Es post-July 14, 2015 data responses play in A4NRs recommendation?

A03:

PG&Es data responses strongly reinforce A4NRs conclusion that key analyses that deserved painstaking review were kept from the IPRP. A4NR requested the deterministic

2 ground motion spectra plots (and associated 10-6 and 10-7 plots) described in A4NR-00660 for joint ruptures on the following linked faults: (i) Hosgri linked to faults up to Mendocino Triple Junction; (ii) Los Osos linked to Hosgri; (iii) San Luis Bay linked to Hosgri; and (iv) Shoreline linked to Hosgri.1 Despite the assurances in A4NR-00660, which was written by Geosciences Director Klimczak in the midst of PG&Es IPRP information blackout period, these deterministic joint rupture analyses never made it into the CCCSIP report.

Q04:

Since each of the deterministic joint rupture plots purports to show ground motion well below the 1977 Hosgri spectrum, what significance does A4NR attach to them?

A04:

The methodologies used to calculate these plots should have been discussed with the IPRP. In explaining how it had derived an M8 assumption for each joint rupture,2 PG&E went further and described the role saturation plays in its results:

The differences in the spectral accelerations at the DCPP site would be negligible between a M8.0 and a M8.5. This is because of the short-distance large-magnitude scaling known as magnitude saturation in ground motion studies. It is accepted within the scientific community, and both empirical observations and numerical simulations validate, that there is not an increase in high-frequency (> 2 Hz) ground shaking levels for close in sites to shallow crustal earthquakes for magnitudes above about magnitude 6.5 (M6.5).

Q05:

Why is that statement significant?

A05:

It effectively immunizes Diablo Canyon from high-frequency ground shaking from earthquakes above M6.5 on close-in faults like Hosgri, Shoreline, San Luis Bay, and Los Osos, 1 PG&Es response ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01, along with the four spectral plots PG&E attached to it, is included in Appendix as Exhibit 1.

2PG&Es response ERRA-2014-PGE-Compliance_DR_A4NR_005-Q01 is included in Appendix as Exhibit 2.

3 not to mention their joint ruptures, and materially underestimates the hazard from near-source, long-period motions associated with large earthquakes.

Q06:

But if this saturation effect is real, what is the problem?

A06:

After consulting with Dr. Blakeslee, A4NR sees several. The magnitude saturation assumption depends upon data extrapolation using far-field earthquakes, because there simply is not much recorded data from large earthquakes in the near-field (although there are some very large accelerations which have been observed in the extreme near-field). The catalog of near-field data that measures the magnitude saturation observationally is small, with a large standard deviation, while using a numerical simulations approach to estimate the effect misses the influence of starting phases, stopping phases, heterogeneous stress drops, and asperities.

And the question of shaking duration needs to be factored in. Put another way: shaking for 10 seconds above a prescribed level is very different from shaking for 60 seconds above the same level. In each case the peak acceleration may only be 0.4g but the damage is significantly greater when the duration of shaking is longer. A structure can literally shake itself to pieces over the longer duration of rupture produced by a long (e.g., 300 km) fault vs. a shorter fault (e.g., 60 km).

Q07:

Can you elaborate on the hazard associated with near-source, long-period motions?

A07:

Dr. Thomas Heaton, Director of the Earthquake Engineering Research Laboratory at the California Institute of Technology (with dual CalTech faculty appointments as a Professor of Geophysics and a Professor of Civil Engineering), expressed written concerns after PG&Es second SSHAC workshop on ground motion characterization:

4 If low frequency motions are a concern (sloshing of storage pools?), then whatever systems are affected are almost certainly not linear systems for very large motions. This means that modal analysis is not appropriate. It is important for the design engineers to directly communicate with scientists about what types of ground motion time histories are plausible. I would strongly discourage the use of spectrum compatible motions to simulate non-linear long-period dynamics.

The spatial distribution of slip is the key parameter that determines the nature of near-source long-period ground motion. For example, two earthquakes of identical magnitude can have very different average slips. Furthermore the maximum slip can be much larger than the average slip. However, when considering low-probability long-period motion, its critically important to characterize the statistical features of slip on segments of a fault that are close to the site. The current analysis does this problem by characterizing the source with moment magnitude, which is an averaging parameter for an earthquake. Variability is handled by assuming that long-period motions are log-normally distributed about the mean appropriate for the magnitude. However, I am not aware of any evidence that shows that the slip at a point is log-normally distributed about the mean. Instead, I would guess that we are looking at a power law distribution (Pareto). For a variety of reasons, I would argue that these slip distributions are approximately fractal in nature. Unfortunately, power law distributions are very hard to deal with when using standard statistical analysis. It may be more appropriate to simply say that PSHA is not well suited for this problem. The key issue is to design structures that are robust with respect to long-period ground motions. (Please see Yamada, M., A. Olsen, and T. Heaton 2009, Statistical features of short-and long-period near-source ground motions, Bull. Seism. Soc. Am., 99: 3264 - 3274)3 Q08:

Did Professor Heatons post-Workshop #2 comments express any view about magnitude saturation in near-source, short-period motions?

A08:

Yes, as follows:

When it comes to high-frequency near-source shaking, the evidence is good that observations are compatible with the hypothesis that pgas saturate with magnitude and that they are approximately log-normally distributed about 1/2 g with a standard deviation of a factor of about 2. You argue that this variability can be decomposed into separate site and source variabilities; this seems to be convincing and I fully support this approach. However, I am concerned about using a log-normal distribution to catch the tails of the distribution. In particular, I am concerned that we have now seen several 3 Southwestern United States Ground Motion Characterization SSHAC Level 3 Workshop #2 Proceedings, Appendix B, pp. B B-2.

5 examples of near-source peak accelerations whose time histories are asymmetric about their zero line (see Yamada, M., J. Mori, and T. Heaton, 2008, The slapdown phase in high acceleration records of large earthquakes, Seismological Research Letters; 80: 559 - 564). It has been hypothesized that this may be an example of slap down, a phenomenon that was well studied by the nuclear explosion test community. Slap down is clearly a nonlinear phenomenon and I would expect its statistics to be independent of the log-normal distribution that are [sic] used to characterize most of the data. Its very difficult to put an upper limit on slap down accelerations. There are many examples of objects that have been launched through the air in violent shaking from past earthquakes. Slap-down seems to be a plausible phenomenon in the near source of earthquakes. 4 (emphases added)

Q09:

To what extent do Professor Heatons concerns reflect a preference for using peak ground displacement (PGD) rather than peak ground acceleration (PGA) as a measure of intensity for long-period ground motions associated with large earthquakes?

A09:

The 2009 research paper referenced in Professor Heatons post-Workshop #2 comments observed, Generally speaking, the energy in ground motions from smaller, more frequent earthquakes is mostly from the short-period content, whereas the energy in ground motions from larger, less frequent earthquakes is primarily in the long-period content.5 The paper pointed out a fundamental divergence between the two methodologies:

As mentioned previously, PGA is known to saturate at magnitudes greater than 6, and the logarithm of PGD is known to increase linearly with respect to magnitude. Thus, there is essentially no correlation between these two intensity measures for near-source ground motions from large events.6 4 Id.

5 Masumi Yamada, Anna H. Olsen, Thomas H. Heaton, Statistical Fetures of Short-Period and Long-Period Near-Source Ground Motions, Bulletin of the Seismological Society of America, Vol. 99, No. 6, December 2009, pp. 3264

- 3274, 3264.

6 Id., p. 3267.

6 Knowing the magnitude does not help predict the PGA because PGA saturates with magnitude, but knowing the magnitude helps to predict PGD because the logarithm of PGD is proportional to the magnitude.7 Q10:

Why does A4NR think it essential that PG&E discuss the deterministic joint rupture analyses with the IPRP before deciding to exclude them from the CCCSIP report?

A10:

Because relegating consideration of joint ruptures to a probabilistic review greatly obscures catastrophic potential and tends to preclude the evaluation of mitigation options. In PG&Es memorable phrase from the ongoing controversy about DCNPPs licensed seismic design basis, the probability is so small that it would mask in PRA space any probability of an issue occurring.8 Q11:

Does that conclude your testimony?

A11:

Yes, it does.

7 Id., p. 3271.

8 GRC2014-Ph-I_DR_A4NR_001-Q02Supp01Atch20 unnumbered p. 2 is included in Appendix as Exhibit 3. PRA is an acronym for probabilistic risk analysis.

Appendix Exhibit 1 ERRA-2014-PGE Compliance_DR_A4NR_004-Q01 Exhibit 2 ERRA-2014-PGE-Compliance_DR_A4NR_005-Q01 Exhibit 3 GRC2014-Ph-I_DR_A4NR_001-Q02Supp01Atch20

Exhibit 1 ERRA-2014-PGE Compliance_DR_A4NR_004-Q01

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01 Page 1 PACIFIC GAS AND ELECTRIC COMPANY 2014 Energy Resource Recovery Account Compliance Review Application 15-02-023 Data Response PG&E Data Request No.:

A4NR_004-01 PG&E File Name:

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01 Request Date:

July 7, 2015 Requester DR No.:

004 Date Sent:

July 31, 2015 Requesting Party:

Alliance for Nuclear Responsibility PG&E Witness:

Kent Ferre Requester:

John Geesman QUESTION 1

32.

Regarding the three-page document A4NR-00660 previously provided to A4NR by PG&E:

(a)

Please identify the author of this document.

(b)

Did PG&E develop the deterministic ground motion spectra plots mentioned in paragraph 4.c. on page 2 of the document for any of the following linked faults?

(i)

Hosgri linked to faults up to Mendocino Triple Junction.

(ii)

Los Osos linked to Hosgri.

(iii)

San Luis Bay linked to Hosgri.

(iv)

Shoreline linked to Hosgri.

(c)

If the response to Question (b) above is negative for any of the linked faults identified, please explain why such work was not performed.

(d)

If the response to Question (b) above is affirmative, please provide copies of such plots as well as all documents and electronically stored information which analyze or discuss such plots.

(e)

Did PG&E perform the hybrid approach described in paragraph 4.c.v.2. on page 2 of the document (i.e., deterministic plots based on magnitudes at 10-6 annual recurrence rate) for the linked faults identified above in Question (b)?

(f)

If the response to Question (e) above is negative for any of the linked faults identified, please explain why such work was not performed.

(g)

If the response to Question (e) above is affirmative, please provide copies of such plots as well as all documents and electronically stored information which analyze or discuss such plots.

(h)

Did PG&E perform the hybrid approach described in paragraph 4.c.v.2.b on page 3 of the document (i.e., deterministic plots based on magnitudes at 10-7 annual recurrence rate) for the linked faults identified above in Question (b)?

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01 Page 2 (i)

If the response to Question (h) above is negative for any of the linked faults identified, please explain why such work was not performed.

(j)

If the response to Question (h) above is affirmative, please provide copies of such plots as well as all documents and electronically stored information which analyze or discuss such plots.

(k)

Please provide copies of the plots described in paragraph 4.e.i. on page 3 of the document (i.e., M8 earthquakes on the Hosgri, SLB, Los Osos, and Shoreline Faults) as well as all documents and electronically stored information which analyze or discuss such plots.

(l)

Please provide copies of the evaluations identified in paragraph 4.e.ii. on page 3 of the document.

(m)

Regarding the evaluations identified in paragraph 4.e.ii. on page 3 of the document, please explain why (i)t was decided to only evaluate the critical SSCs in any frequencies of exceedance range to show they can perform their safety functions.

ANSWER 1 PG&E responds as follow:

a) Richard Klimczak, retired Director of Geosciences.

b) Yes. PG&E developed 84th percentile, deterministic plots for all the linked fault scenarios. The magnitudes are all M8 and spectra are provided for both the turbine building (TB) site and the power block (PB) site.

c) Not applicable.

d) PG&E objects to this data request as overbroad and burdensome.

Notwithstanding this objection, PG&E responds as follows:

Attachments 1 and 2 to this response provide the deterministic ground motion spectra plots referred to in PG&Es response to subpart b) of this data request.

They are for the PB site and the TB site, respectively.

e) Yes. PG&E developed 84th percentile deterministic spectra using the hybrid approach for the TB site. The plots are based on magnitudes at 10-6 annual recurrence rate. The magnitude recurrence curves used for the analysis were based on the Wells and Coppersmith magnitude-distribution scaling, and the Wooddell et al upper bound model.

f) Not applicable.

g) PG&E objects to this data request as overbroad and burdensome.

Notwithstanding this objection, PG&E responds as follows:

to this response provides the deterministic ground motion spectra plots referred to in PG&Es response to subpart e) of this data request.

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01 Page 3 h) Yes. PG&E developed 84th percentile deterministic spectra using the hybrid approach. The plots are based on magnitudes at 10-7 annual recurrence rate.

The spectra are provided for the TB site. The magnitude recurrence curves used for the analysis were based on the Wells and Coppersmith magnitude-distribution scaling, and the Wooddell et al upper bound model.

i) Not applicable.

j) PG&E objects to this data request as overbroad and burdensome.

Notwithstanding this objection, PG&E responds as follows:

to this response provides the deterministic ground motion spectra plots referred to in PG&Es response to subpart h) of this data request.

k) PG&E objects to this data request as overbroad and burdensome.

Notwithstanding this objection, PG&E responds as follows:

Attachments 1 and 2 to this response provide the deterministic ground motion spectra plots that are responsive to this subpart of this data request.

l) PG&E objects to this data request insofar as it seeks information that is beyond the scope of this proceeding. SSC studies are not part of the studies whose costs are recovered in the Diablo Canyon Seismic Studies balancing account (DCSSBA). Notwithstanding this objection, PG&E responds as follows:

Evaluations done compared the deterministic plots to the 1977 Hosgri Earthquake response spectrum. These comparisons are included in each of the attachments to this data response. Since the safety critical structures, systems, and components (SSCs) are designed to withstand (with margin) ground shaking level defined by the 1977 Hosgri Earthquake response spectrum, and since the plots provided in response to this data request all fall below the 1977 Hosgri Earthquake response spectrum curve, the SSCs can withstand shaking from the M8 earthquakes whose spectra are provided in response to this data request.

m) PG&E objects to this data request insofar as it seeks information that is beyond the scope of this proceeding. SSC studies are not part of the studies whose costs are recovered in the DCSSBA. Notwithstanding this objection, PG&E responds as follows:

Non-safety critical SSCs were not evaluated because they are not required to function to safely shut down the plant.

Deterministic 84th percentile spectra for the power block foundation level assuming a magnitude 8 earthquake on each source.

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01Atch01

Deterministic 84th percentile spectra for the turbine building foundation level assuming a magnitude 8 earthquake on each source.

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01Atch02

Deterministic 84th percentile spectra for the turbine building foundation level using the magnitude for a 1E-6/yr rate of occurrence.

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01Atch03

Deterministic 84th percentile spectra for the turbine building foundation level using the magnitude for a 1E-7/yr rate of occurrence.

ERRA-2014-PGE-Compliance_DR_A4NR_004-Q01Atch04

Exhibit 2 ERRA-2014-PGE-Compliance_DR_A4NR_005-Q01

ERRA-2014-PGE-Compliance_DR_A4NR_005-Q01 Page 1 PACIFIC GAS AND ELECTRIC COMPANY 2014 Energy Resource Recovery Account Compliance Review Application 15-02-023 Data Response PG&E Data Request No.:

A4NR_005-01 PG&E File Name:

ERRA-2014-PGE-Compliance_DR_A4NR_005-Q01 Request Date:

August 4, 2015 Requester DR No.:

005 Date Sent:

August 12, 2015 Requesting Party:

Alliance for Nuclear Responsibility PG&E Witness:

Kent Ferre Requester:

John Geesman QUESTION 1

33.

Please describe the methodology, or explain the rationale, used by PG&E to assign a magnitude 8 earthquake to calculate the deterministic ground motion spectra plots mentioned in paragraph 4.c. on page 2 of A4NR-00660 for joint ruptures on each of the following linked faults:

(i)

Hosgri linked to faults up to Mendocino Triple Junction.

(ii)

Los Osos linked to Hosgri.

(iii)

San Luis Bay linked to Hosgri.

(IV)

Shoreline Linked To Hosgri.

ANSWER 1 The magnitudes are based on established magnitude scaling methods (e.g., Hanks and Bakun). For each of the four cases listed above, the linkage assumed the rupture extended to the Mendocino Triple Junction for a magnitude M8. Note that in the Senior Seismic Hazard Analysis Committee (SSHAC) Seismic Source Characterization (SSC) model, the magnitude was conservatively increased to M8.5. Deterministic plots were not rerun for magnitude M8.5.

The differences in the spectral accelerations at the DCPP site would be negligible between a M8.0 and a M8.5. This is because of the short-distance large-magnitude scaling known as magnitude saturation in ground motion studies. It is accepted within the scientific community, and both empirical observations and numerical simulations validate, that there is not an increase in high-frequency (> 2 Hz) ground shaking levels for close in sites to shallow crustal earthquakes for magnitudes above about magnitude 6.5 (M6.5).

Exhibit 3 GRC2014-Ph-I_DR_A4NR_001-Q02Supp01Atch20

  • 5&3K,B'5B$15B46XSS$WFK