DUKE POWER COMPANY EMERGENCY DOSE ASSESSMENT MANUAL March 18, 1991

EMERGENCY DOSE ASSESSMENT MANUAL DISTRIBUTION LIST CONTROL NUMBER HOLDER 1

R. E. Harris 2

W. P. Deal 3

M. L. Birch 4

C. T. Yongue 5

Caryl Ingram 6

R. E. Sorber 7

Open 8

D. P. Simpson 9

F. G. Hudson 10 J. W. Foster 11 J. E. Cole 12 P. N. McNamara 13 J. J. Honeycutt (ONS CMC Managers Area) 14 R. N. Keener 15 J. J. Honeycutt (MNS/CNS CMC Managers Area) 16 W. B. McRee 17 NRC Document Control Desk (via Helen Froebe) 18-19 NRC Regional Administrator (via Helen Froebe) 20 NRC Resident Inspector-Catawba (via Helen Froebe) 21 NRC Resident Inspector-McGuire (via Helen Froebe) 22 NRC Resident Inspector-Oconee (via Helen Froebe)

TABLE OF CONTENTS EDA-1 Procedure for Estimating Food Chain Doses Under Post-Accident Conditions (Rev. 2)

EDA-2 Off-Site Dose Projections for Catawba Nuclear Station (Rev. 5)

EDA-3 Off-Site Dose Projections for McGuire Nuclear Station (Rev. 7)

EDA-4 Off-Site Dose Projections for Oconee Nuclear Station (Rev. 6)

EDA-5 Mesorem, Jr. Atmospheric Dispersion and Dose Assessment Model Users Manual, Version 4A Catawba (Rev. 0)

EDA-6 Mesorem, Jr. Atmospheric Dispersion and Dose Assessment Model Users Manual, Version 4A McGuire (Rev. 0)

EDA-7 Mesorem, Jr. Atmospheric Dispersion and Dose Assessment Model Users Manual, Version 4A Oconee (Rev. 0)

EDA-8 Environmental Monitoring for Emergency Conditions for Catawba Nuclear Station (Rev. 6)

EDA-9 Environmental Monitoring for Emergency Conditions for McGuire Nuclear Station (Rev. 8)

EDA-10 Environmental Monitoring for Emergency Conditions for Oconee Nuclear Station (Rev. 1)

March 18, 1991

CRISIS MANAGEMENT PLAN IMPLEMENTING PROCEDURE EDA -

2 "Off-Site Dose Projections for Catawba Nuclear Station" Approved By Date Rev. 5 March 30, 1990

EDA-2 Page 1 of 11 Offsite Dose Projections for Catawba Nuclear Station 1.0 PURPOSE To describe a method for projecting dose commitment from a noble gas and/or iodine release, through the containment, the unit vent and/or the steam relief valves, during an emergency.

2.0 REFERENCES

2.1 HP/O/B/1000/10, Determination of Radiation Monitor Setpoints 2.2 HP/0/B/1009/06, Alternative Method for Determining Dose Rate Within the Reactor Building 2.3 HP/0/B/1009/14, Hlcalth Physics Actions Following an Uncontrolled Release of Liquid Radioactive Material 2.4 HP/O/B/1009/17, Unit 1 Post-Accident Containment Air Sampling System 2.5 IIP/0/B/1009/21, Abnormal Unit Vent Sampling 2.6 CNS Technical Specification 3.6.1.2 2.7 Offsite Dose Calculation Manual (ODCM) 2.8 Regulatory Guide 1.4, "Assumptions Used for Evaluating the Potential Radiological Consequences of a Loss of Coolant Accident for Pressurized Water Reactors" 2.9 Regulatory Guide 1.109, "Calculations of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR Part 50, Appendix I" 2.10 NuReg-0396, EPA 520/1-78-016, "Planning Basis for the Development of State and Local Government Radiological Emergency Response Plans in Support of Light Water Nuclear Power Plants" 2.11 NuReg-0654, FEMA-REP-1, Rev.

1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants" 2.12 Letter from F. G. Hudson, September 30, 1985, re:

Release Rate Information for McGuire and Catawba Nuclear Station (File:

CN-134.10) 2.13 Catawba Nuclear Station Class A Computer Model Validation (File:

NUC-0306) 2.14 Letter from J. E. Thomas, May 19, 1987, File:

CN-1346.05 and personal conversation with Frank Poley 2.15 Radioiodine and Particle Transmission Through Plant Vent Sampling Lines at Catawba Nuclear Station, prepared by SAIC, dated July 1989.

EDA-2 Page 2 of 11 3.0 LIMITS AND PRECAUTIONS 3.1 This procedure is an alternative method of dose assessment to the Catawba Class A Atmospheric Dispersion Model computer code.

3.2 This procedure applies to releases made from Catawba Nuclear Station only. Many of the values contained in this procedure are site specific.

3.3 It is assumed that the whole body dose from an iodine release is very small compared to the thyroid dose; therefore, iodine whole body dose is not considered here.

3.4 This procedure considers all releases to be ground level releases and that meteorological data are 15 minute averages.

3.5 Once a zone has been added to the list of affected zones, it shall not be removed except under the direction of the Dose Assessment Coordinator.

3.6 Once the Crisis Management Center (CMC) has been activated, the doses calculated by the Technical Support Center (TSC) dose assessment group, should be compared with those calculated by the CMC before an evacuation recommendation is made.

4.0 PROCEDURE 4.1 Meteorology Assessment 4.1.1 Acquire the following information and record on the Dose Assessment Worksheet (Enclosure 5.1):

4.1.1.1 Lower tower wind speed (WS) in miles per hour.

4.1.1.1.1 Use upper tower wind speed if lower tower wind speed is not available.

4.1.1.2 Upper tower wind direction in degrees from North (North = 0).

4.1.1.2.1 Use lower tower wind direction if upper tower wind direction is not available.

4.1.1.2.2 If the wind speed or wind direction cannot be obtained from plant systems, obtain them from the National Weather Service (phone 704-359-8466).

If the NWS information is unavailable, then obtain data from McGuire Nuclear Station Control Room (73 or 78, then 875, then ext. 4262, or 4263, or 4264).

EDA-2 Page 3 of 11 4.1.1.3 Temperature gradient (AT) in degrees centigrade.

4.1.1.4 Using Enclosure 5.2, record the stability class based on AT.

4.1.1.4.1 If the temperature gradient is unknown, the following applies:

If between 1000 -

1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br />, use stability class D; If between 1600 -

1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br />, use stability class G.

4.1.1.5 If necessary, use forecasted meteorological data for calculating doses due to changing meteorological conditions.

4.1.2 Determine the atmospheric dispersion parameter, X/Q (sec/m 3 ), for.5, 2, 5 and 10 miles (record on Enclosure 5.1, page 2):

4.1.2.1 Use AT, determine the two hour relative concentration value (C ) from Enclosure 5.2.

4.1.2.2 Convert the C H values to X/Q:

X/Q =

H wS 4.2 Source Term Assessment -

Steam Relief Valve (Enclosure 5.4) 4.2.1 Determine the Sub-Noble Gas Release Rates, SQNG (Ci/sec),

by the following method:

4.2.1.1 For Unit l-EMF26, EMF27, EMF28 and EMF29 or for Unit 2-EMF10, EMF11, EMFl2, EHF13:

SQNG =

R/hr x 1

x LBM x CF Ci VOPEN ibm R/hr where:

R/hr EMF26, EMF27, EHF28, EMF29, EMF10, EMF11, EMFl2, EMFl3 reading VOPEN=

time the valve is open in seconds LBM

=

lbm released for the time the valve was open CF

=

correction factor per Enclosure 5.5

EDA-2 Page 4 of 11 4.2.2 Determine the Noble Gas Release Rate, QNG(Ci/sec):

QNG = SQNG(EMF 2 6 ) + SQNG(EMF 2 7 ) + SQNG(EMF 2 8) +

SQ NG(EMF 2 9 )

4.2.3 Determine the Iodine release rate, Q (Ci/sec):

Q=

QNG x Irat where:

Irat = ratio of 1131 eqv./Xel33 eqv. from Enclosure 5.6.

4.2.4 Record QNG and Q on Enclosure 5.1, page 2.

4.3 Source Term Assessment - Containment (Enclosure 5.7) 4.3.1 Determine the Noble Gas Release Rate, QNG(Ci/sec) based on one of the following methods; 4.3.1.1 Based on an EMF reading, where; QNG = EMF x CF x LR where; EMF = 39(L), if EMF39(L) <1E7 cpm and flowpatb not isolated, EMF = 39(H), if EMF39(L) is offscale and EMF39(H) > 100 cpm and flowpath not isolated, EMF = 53A or 53B, if EMF39(H) is offscale.

Use survey meter reading (Reference 2.2) if 53A and 53B are not available.

CF =

correction factor per Enclosure 5.8.

LR = Leak Rate x BYPASS, Leak Rate, (al/hr), by one of the following methods:

based on containment pressure:

LR = RLR (from Enclosure 5.9) based on an opening in containment:

LR = OIC (from Enclosure 5.10) based on design leak rate:

LR = 2.449E6 (Reference 2.13)

BYPASS = Bypass leakage, default is 7%

or 0.07 (Reference 2.6)

EDA-2 Page 5 of 11 4.3.1.2 Based on PACS sample, where; QNG = PACS x CF x LR where; PACS = pCi/ml (Reference 2.4)

CF

= 2.78E-10 Ci hr sec pCi LR

= Leak rate, as determined in Step 4.3.1.1 above 4.3.2 Detemine the Iodine Release Rate, Q (Ci/sec) based on one of the following methods:

4.3.2.1 Based on Q NG Q

= QNG x Irat where:

QNG = Noble Gas Release Rate as determined in Step 4.3.1 above Irat = ratio of 1131 eqv./Xe 133 eqv. from.6.

4.3.2.2 Based on EMF 40 (if flowpath is not isolated);

Q=

ACPM x 9.82E-20 Ci hr min x LR Amin sec ml cpm where:

ACPM = reading from EMF40 Delta Counts Amin = the time interval for EMF40 observation (normally 15 minutes) 9.82E-20 = 4.OE-5 pCi/cpm x.25 min/ft3 (inverse of EMF flow rate) x 3.53-5 ft3/ml x lCi/1E6 pCi x 1 hr/3600 sec.

4.OE-5 = correlation factor for EMF40 from Reference 2.1.

LR

= Leak rate, as determined in Step 4.3.1.1 above

EDA-2 Page 6 of 11 4.3.2.3 Based on PACS sample; Q

= PACS x CF x LR where; PACS = (pCi/ml) (Reference 2.4)

CF = 2.78E-10 Ci hr sec pCi LR

= Leak rate as determined in Step 4.3.1.1 above 4.3.3 Record QNG and Q on Enclosure 5.1, page 2.

4.4 Source Term Assessment - Unit Vent (Enclosure 5.11) 4.4.1 Determine the Noble Gas Release Rate, Q NG(Ci/sec) based on one of the following methods:

4.4.1.1 Based on as EMF reading, where; QNG = EMF x CF x CFM where:

EHF = 36(L) if EMF36(L) < 1E7 cpm, EMF = 36(H) if EMF36(L) is offscale and EMF36(H) > 100 cpm and compressor not

tripped, EMF = 54 if EMF36(H) is offscale or compressor tripped.

CF = correction factor per Enclosure 5.12 CFM = unit vent flow rate (ft3 /min) 4.4.1.2 Based on unit vent sample, where; QNG = Unit Vent Sample x CF x CFM where:

Unit Vent Sample = (pCi/ml) per Reference 2.5 CF 4.72E-4 Ci min ml sec ft3 pci CFM = unit vent flow rate (ft3 /min)

EDA-2 Page 7 of 11 4.4.2 Determine the Iodine Release Rate, Q (Ci/sec), based on one of the following methods:

4.4.2.1 Based on QNG' Q

= QNG x

Irat where:

QNG = Noble Gas Release Rate as determined in Step 4.4.1 above Irat = ratio of 1131 eqv./Xel33 eqv. from.6.

4.4.2.2 Based on EMF 37 (if compressor not tripped);

ACPM x 1.33E-13 Ci min min x CFM = Q Amin sec ft3 cpm where:

ACPM = reading from EMF37 Delta Counts Amin = the time interval from EMF37 observation (normally 15 minutes) 1.33E-13 = 4.OE-5 pCi/cpm x 0.1667 min/ft3 (inverse of EMF flow rate) x 1Ci/1E6 pCi x 1 min/60 sec. x 1.2 where:

4.OE-5

= correlation factor for EMF37 from Reference 2.1.

1.2

= inverse of iodine transmission factor (see Reference 2.15)

CFM

= unit vent flow rate (ft'/min) 4.4.2.3 Based on unit vent sample:

Q = Unit vent sample x 4.72E-4 Ci min ml x CFM sec ft3 pCi where:

Unit vent sample = (pCi/ml) (Reference 2.5)

CFM = unit vent flow rate (ft3 /min) 4.4.3 Record.NG and 0 on Enclosure 5.1, page 2.

EDA-2 Page 8 of 11 4.5 Dose Assessment (Enclosure 5.1 or Class A computer printout) 4.5.1 On Item 1, record if this information is for a drill or real emergency.

4.5.2 On Item 4, record which unit is affected.

4.5.3 On Item 9:

4.5.3.1 If normal plant conditions exist, circle A.

N/A Items 10 through 13.

Go to step 4.5.8.

4.5.3.2 If an emergency event is occurring and releases are less than operational limits and:

4.5.3.2.1 Containment pressure is less than 1 psig, circle B or, 4.5.3.2.2 Containment pressure is greater than or equal to 1 psig with increased reactor building activity or steam generator tube leak exists or increased unit vent activity exists or field teams report activity, circle E, but do not provide dose calculations to state/counties.

4.5.3.3 If an emergency event is occurring and releases are greater than operational limits, circle C if releases are occurring or D if they have already occurred.

4.5.4 On Item 10, record what type of release has occurred.

4.5.5 On Item 11, record the noble gas and iodine release rates (curies per second) from all releases.

4.5.5.1 If available, record the highest iodine/xenon ratio.

4.5.6 On Item 12, record the reactor status.

4.5.6.1 If the reactor has not tripped, use the data sheet date/time as the time of reactor trip.

On the computer printout, cross out the shutdown time/date and record the % Power from the data sheet.

4.5.7 On Item 13, record the dose rates and the integrated doses.

4.5.7.1 If new doses were calculated, check the NEW block.

EDA-2 Page 9 of 11 4.5.7.2 The duration is the total time of previous releases plus the time estimated for the projected release.

4.5.7.3 The integrated dose (mrem) is the total dose from all releases plus the dose from the projected release.

4.5.7.4 If information is available contradicting the calculated doses, change the data to reflect the new values.

4.5.7.5 On Enclosure 5.1:

4.5.7.5.1 Determine the Projected Whole Body Dose Rate, DRwb (rem/hr), due to the noble gases for.5, 2,

5 and 10 miles:

DRwb = 33.6 rem m3 x TQNG x X/Q br Ci where:

33.6 is the adult whole body dose conversion factor from Reference 2.9 in rem m hr Ci 4.5.7.5.2 Determine the Projected Whole Body Dose, Dwb(rem), due to noble gases for.5, 2,

5 and 10 miles:

Dwb = DRwb x 2 hr where:

dose is integrated over 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> time period 4.5.7.5.3 Determine the Projected Thyroid Dose Rate, DRct (rem/hr), due to iodine for.5, 2,

5 and 10 miles:

DRct = X/Q x TQ x 2.26E6 rem m3 hr Ci where:

2.26E6 is the child thyroid dose conversion factor from Reference 2.13 in rem m3 hr Ci

EDA-2 Page 10 of 11 4.5.7.5.4 Determine the Projected Thyroid Dose, Dct(rem),

due to iodine for

.5, 2, 5 and 10 miles:

Dct = DRct x 2 hr where:

dose is integrated over 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> time period 4.5.8 On Item 14, record the meteorological data.

4.5.9 On Item 16, this section is for the TSC Dose Assessment Coordinator or the CMC off-Site Dose Assessment Director.

4.6 Protective Action Recommendations (Enclosure 5.1 or Class A computer printout):

4.6.1 Circle on Enclosure 5.1 the Protective Action Zones (PAZ),

based upon 1) the wind speed and wind direction, using.3; and 2) the projected dose from Enclosure 5.1 compared to the following.

4.6.2 If the projected dose in a PAZ is < 1 rem whole body or

<5 rem thyroid, then recommend no protective action (action A).

4.6.3 If the projected dose in a PAZ is 1 - 5 rem whole body or 5 -

25 rem thyroid, then recommend to consider evacuating pregnant women and children and shelter all other PAZs (actions OTHER and B).

4.6.4 If the projected dose in a PAZ is > 5 rem whole body or

> 25 rem thyroid, then recommend evacuate everyone and shelter all other PAZs (actions C and B).

4.6.5 Recheck meteorology conditions approximately every 15 minutes to ensure that other sectors have not been affected.

4.7 Emergency Classification (Enclosure 5.1) 4.7.1 Check the box indicating the emergency classification based upon the following.

4.7.2 If the dose rate at the site boundary is

> 5.OE-4 rem/hr whole body then recommend an Alert.

4.7.3 If the dose rate at the site boundary is

.05 rem/hr whole body or >

.25 rem/hr thyroid, then recommend a Site Area Emergency if readings last 30 minutes.

4.7.4 If the dose rate at the site boundary is >

.5 rem/hr whole body or > 2.5 rem/hr thyroid, then recommend a Site Area Emergency if readings last 2 minutes.

EDA-2 Page 11 of 11 4.7.5 If the dose rate at the site boundary is > 1 rem/hr whole body or > 5 rem/hr thyroid, then recommend a General Emergency.

5.0 ENCLOSUES 5.1 Sample of Meteorology Source Term and Dose Assessment Worksheet 5.2 Two-hour Relative Concentration Factors (CH) 5.3 Protective Action Zones Determination 5.4 Sample of Source Term Assessment - Steam Relief Valves 5.5 EMF26, EMF27, EMF28, EMF29 or EMF10, EMF11, EMFl2, EMF13 Noble Gas Correction Factor 5.6 1131 eqv./Xe 133 eqv. Ratio 5.7 Sample of Source Term Assessment -

Containment 5.8 Containment Noble Gas Correction Factor 5.9 Containment Leakage Rate versus Pressure 5.10 Containment Leakage Rate versus Pressure and Size Opening 5.11 Sample of Source Term Assessment - Unit Vent 5.12 Unit Vent Noble Gas Correction Factor 5.13 Integrated Dose

DUKE POWER COMPANY Page 1 of 2 CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.1 METEOROLOGY, SOURCE TERM AND DOSE ASSESSMENT EMERGENCY NOTIFICATION

1.

THIS IS A(N)

DRILL EMERGENCY

4.

SITE:

Catawba Unit

9.

EMERGENCY INVOLVES:

A. NO RELEASE (If A, go to 14.)

B. POTENTIAL RELEASE C. A RELEASE IS OCCURRING:

Started Expected Duration_

D. A RELEASE HAS OCCURRED:

Started Stopped E. THE RELEASE IS WITHIN NORMAL OPERATIONAL LIMITS

10.

TYPE OF RELEASE:

GROUND LEVEL A. RADIOACTIVE GASES C. RADIOACTIVE PARTICULATES B. RADIOACTIVE LIQUIDS D. OTHER

11.

RELEASE:

CURIES PER SEC.

A. NOBLE CASES C.

IODINES B. IODINE/NOBLE GAS RATIO (If available)

OTHER

12.

REACTOR STATUS:

A. SHUTDOWN:

TIME/DATE_/

B.

%POWER (EASTERN)

MM/DD/YY

13.

ESTIMATE OF PROJECTED OFFSITE DOSE:

-NEW UNCHANGED DURATION:

HRS.

Whole Body Child Thyroid DOSE RATE DOSE RATE Whole Body Child Thyroid Distance mrem/hr mrem/hr mrem mrem Site Boundary 2

miles 5

miles 10 miles

14.

METEROLOGICAL DATA:

NOT AVAILABLE A. WIND DIRECTION (from) ____degrees C. STABILITY CLASS B.

WIND SPEED (mph)

D.

PRECIPITATION (type)

15.

RECOMMENDED PROTECTIVE ACTIONS:

A. NO RECOMMENDED PROTECTIVE ACTIONS B. SHELTER AO B1 El Al Cl D1 F1 B2 A2 C2 D2 E2 F2 F3 A3 C. EVACUATE AO Bl El 1A Cl D1 F1 B2 A2 C2 D2 E2 F2 F3 A3 D. OTHER

16.

APPROVED BY:

(NAME)

(TITLE)

TIME/DATE:

/

(EASTERN) mm dd yy NOTES:

1) For all evacuations, recommend that the remainder of the 10 mile emergency planning zone stay indoors.
2) Compare these recommendations with other groups' recommendations that the Emergency Coordinator/Recovery Manager reviews.

DUKE POWER COMPANY Page 2 of 2 CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.1 METEOROLOGY, SOURCE TERM AND DOSE ASSESSMENT Projection based on data on

//Time since trip hrs.

Miles

.5 1

2 4

5 7

8 PAZ AO BI El Al Cl Dl Fl B2 A2 C2 D2 E2 F2 F3 A3 Total Source Term Assessment a Current a

Hypothetical Steam Relief Containment Unit Vent Encl. 5.4 Encl. 5.7 Encl. 5.11 Ci/sec

+

Ci/sec +

Ci/Sec =

Ci/Sec (TQNG)

Ci/sec +

Ci/sec +

Ci/Sec =

Ci/Sec (TQ )

Source Term Based on

1. LOCA
5. Tube Rupture
2. LOCA (charcoal)
6. New Fuel Accident (< 100 days old)
3. Melted Core
7. Old Fuel Accident (> 100 days old)
4. Melted Core (charcoal)
8. Waste Gas Decay Tank Dose Assessment C = X WS Adult whole body Child thyroid 2 hr 2 hr Dose = 2 x DRwb = 33.6 x TQ x

X/Q x TQ x 2.26E6

=DRct x 2 = Dose (rem)

(rem/hr)

(CMsec) (sec/m')

(i/sec)

(rem/hr)

(rem)

Distance miles

=2 x

= 33.6 x TQNG

.5 TQ x 2.26E6 =

x 2=

=2x= 36 QNG 2

QIx2.66=

-x=

=2 x

= 33.6 x TQNG 2

TQ x 2.26E6 = _

x 2=

=2 x

= 3 3.6 x TQNG 5

TQ x 2.26E6 =

x 2=

=2 x

33.6 x TQNG 10 TQ x 2.26E6

x 2=

=__2 x

= 3 3.6 xTQN 1

TQ x 2.26E6 =

x2 2=

=2 x

= 3 3.6 x TQNG 4

TQ x 2.26E6 =

x 2=

=2 x

= 3 3.6 x TQNG 7

TQ x 2.26E6 =

x 2=

=2 x

=

3 3.6 x TQNG 8

TQ x 2.26E6 =

x 2=

Review with Emergency Coordinator the recommended Emergency Classification.

o3 Recommend Alert a

Recommend Site Area Emergency if readings last 30 minutes a

Recommend Site Area Emergency if readings last 2 minutes a

Recommend General Emergency

EDA-2 DUKE ER COMPANY E

RE 5.2 ThG-HOUR RELATIVE CONCENTRATION FACTORS(C H

I Temperature Stability j Distance (miles)

IGradient (C)

I Class j

.5 1 I 2 I 3 I 4 5

l 6

j 7 I 8

I 9

10 I

1I 111111111111 I

II 111111111111 I

I I 1) aT<-0.6 I

A I 1.4E-5 1.2E-6 I 5.9E-71 4.1E-7 I 3.2E-7 1 2.5E-7 I 2.OE-7 I 1.9E-7 I 1.8E-7 I 1.6E-7 I 1.5E-7 I II 111111111111I I

1 1

I I

llI I

I I 2) -0.6<AT<-0.5 C

1.15E-4 l 4.5E-5 I 1.3E-51 6.3E-6 I 3.9E-6 I 2.7E-6 I 1.9E-6 I 1.4E-6 I 1.1E-6 I 8.3E-7 I 7.8E-7 1

I 1

IlIll!

II 11111111111 I

3) -0.5AtT<-0.2 I D

l 3.8E-4 I 1.4E-4 I 4.9E-SI 2.7E-5 1.7E-5 I 1.2E-5 I 9.2E-6 7.3E-6 6.OE-6 I 5.OE-6 4.3E-6 I I

1111111111I 1

IllllI IlII I 4) -0.2cAT<+0.4 J E

j 6.9E-4 j 2.5E-4 9.6E-51 5.5E-5 I 3.SE-5 I 2.5E-5 2.0E-5 I 1.6E-5 I 1.3E-5 I 1.1E-5 I 9.7E-6 I II II Illl llll I 5) *0.4<aT<+1.2 l F

I 1.1E-3 I 5.1E-4 I 2.OE-41 1.2E-4 I 8.2E-5 I 6.3E-5 I 5.lE-5 I 4.3E-5 I 3.8E-5 I 3.3E-5 I 3.OE-5 l I 6) +1.2<aT G

I 1.8E-3 1.1E-3 4.3E-41 2.7E-4 I 2.OE-4 I 1.7E-4 I 1.3E-4 I 1.2E-4 I 8.6E-5 I 7.8E-5 I 7.3E-5 NOTE:

If AT is ravailable use:

1000-1600 hours Use Stability Class D 1600-1000 hours Use Stability class G

DUKE POWER COMPANY CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.3 PROTECTIVE ACTION ZONES DETERMINATION Determine the affected zones (based on wind direction) from the table below and record on Enclosure 5.1.

NOTE:

If wind speed is less than or equal to 5 mph, the affected zones for 0-5 miles shall be AO, Al, B1, C1, D1, El, Fl.

Wind Direction PAZ's (degrees from North) 0-5 miles 5-10 miles 0.0 -

22 AO, Cl, D1 C2, D2 22.1 -

73 AO, Cl, D1, El C2, D2, E2, F2 73.1 -

108 AO, C1, D1, El, F1 D2, E2, F2, F3 108.1 -

120 AO, D1, El, F1 D2, E2, F2, F3 120.1 -

159 AO, El, Fl D2, E2, F2, F3, A2 159.1 -

207 AO, E1, Fl, Al E2, F2, F3, A2, B2 207.1 -

247 AO, Fl, Al, B1 F2, F3, A2, B2 247.1 -

265 AO, Al, Bl F3, A2, B2, A3, C2 265.1 -

298 AO, Al, B1, C1 A2, B2, A3, C2 298.1 -

338 AO, B1, Cl B2, A3, C2, D2 338.1 -

359.9 AO, B1, Cl, Dl B2, C2, D2

DUKE POWER COMPANY CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.4 SOURCE TERM ASSESSMENT -

STEAM RELIEF VALVES Report #

Reactor Trip

/

Projection based on data on ____/

(Date/Time)

(Date/Time)

Calculations based on Melted Core LOCA NOBLE GAS based on EMF26 or EMF10 SGNG R/hr x 1

l sec x

lbm x Ci =

Ci ibm R/br sec (Encl. 5.5) based on EMF27 or EMFll R/hr x I 1

l l _sec lx lbm x Ci =

Ci lbm R/hr sec (Encl. 5.5) based on EMF28 or EMFl2 R/hr x l

1 l

sec Ix 1bm x Ci =

Ci ibm R/hr sec (Encl. 5.5) based on EMF29 or EMFl3 R/hrx l

1 l

sec Ix 1bm x Ci =

Ci

_lbm R/hr sec (Encl. 5.5)

Total from all Steam Relief Valves, QNG Ci/sec IODINE From all Steam Relief valves QI QNG x

1131 eqv./Xe 133 eqv. ratio

=_Ci/sec (Encl. 5.6) 0 Emergency 0 Drill Prepared by:

DUKE POWER COMPANY.

CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.5 EMF26, EMF27, EMF28, EMF29 or

EMF10, EMFI, EMF12, EMF13 NOBLE GAS CORRECTION FACTOR Time Since Trip (hrs)

Correction Factor based on Melted Core or LOCA

>0 3.622

>2 3.971

>4 4.041

>8 4.029

>24 3.332

>48 2.647

>100 2.438

>250 2.438

>500 2.438

>720 2.438

  • units in Ci Ibm R/hr
  • Enclosure 5.5 is the correlation factor per Reference 2.13 x 2.83E4 ml x.41 ft 3 x

m3 ft 3 ibm 1E6 ml

.41 = specific gravity of steam per Reference 2.13.

DUKE POWER COMPANY CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.6 1131 eqv./Xel33 eqv. RATIO Ratio based on Ratio based on LOCA Melted Core Time Since Trip (hrs)

(Column 1)

(Column 2)

>0 2.74E-3 2.24E-3

>2 3.42E-3 9.66E-3

>4 3.82E-3 1.59E-2

>8 4.34E-3 2.85E-2

>24 4.79E-3 7.52E-2

>48 4.84E-3 1.11E-1

>100 5.06E-3 1.33E-1

>250 6.55E-3 1.80E-1

>500 1.02E-2 2.90E-1

>720 1.44E-2 4.33E-1

  • Enclosure 5.6 is from Reference 2.13.

NOTE:

For unit vent releases in which Irat is utilized to determine 1-131 equiv. concentration, apply the appropriate correction from the table below:

1.

LOCA, use column 1 (based on LOCA).

2.

LOCA through charcoal filters, divide column 1 value by 100.

3.

Core damage, use column 2 (based on Core Melt).

4.

Core damage through charcoal filters, divide column 2 value by 100.

5.

Tube rupture, use 1.44E-5

6.

New fuel accident, use 2.217E-4

7.

Old fuel accident, use 7.217E-4

8.

Gas decay tank, assume no radioiodine released, only noble gases are considered to be released from gas tank, use 0.

NOTE:

For steam releases in which Irat is utilized to determine 1-131 equiv. concentration, apply the appropriate correction from the table below:

1.

LOCA divide column 1 value by 100.

2.

Core damage, divide column 2 value by 100.

DUKE POWER COMPANY CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.7 SOURCE TERM ASSESSMENT - CONTAINMENT Report Reactor Trip

/

Projection based on data on

/

(Date/Time)

(Date/Time)

Calculations based on Melted Core LOCA Containment pressure psig LR =

ml/hr x BYPASS (default =

.07)

LR based on Realistic Leak Rate (check one) 1" 2"

411 6"

8" 12" 1811 34" diameter opening (circle one) Personnel Hatch opening Equipment Hatch opening Design Leak Rate (2.449E6)

NOBLE GAS based on (check one) 0 EMF39(L) if < 1E7 cpm a EMF39(H) if > 100 cpm o EMF53 if 39(H)

Is off scale EMF CF LR QNG cpm or x

x ml/hr

=

Ci R/hr (Encl. 5.8) sec (Note on Encl. 5.9) based on PACS sample pCi/ml x 2.78E-10 Ci br x

ml/hr

=_

Ci sec pCi sec IODINE based on QNG I

Ci x

1131 eqv./Xel33 eqv.

=

Ci sec ratio (Encl. 5.6) sec based on EMF40 LR ACPM x 9.82E-20 Ci hr min x ml/hr

=

Ci Amin sec ml cpm sec based on PACS sample

_CI x

2.78E-10 Ci hr x

ml/hr

=

Ci ml sec pCi see o Emergency o Drill Prepared by:

0 EDA-2 DUKE POWER COMPANY ENCLOSURE 5.8 CATAWBA CONTAINMENT NOBLE GAS CORRECTION FACTOR Time Since EMF 39(L)

EMF 39(H)

EMF 53 Trip (hours) based on based on based on LOCA Melted Core LOCA Melted Core LOCA Melted Core

>0 6.389E-18 6.672E-17 5.56E-14 1.429E-13 3.781E-10 1.190E-9

>2 6.389E-18 4.448E-17 5.56E-14 1.003E-13 3.114E-10 5.894E-10

>4 6.389E-18 3.058E-17 5.56E-14 1.232E-13 2.780E-10 4.726E-10

>8 6.389E-18 2.113E-17 5.56E-14 1.195E-13 2.446E-10 3.392E-10

>24 6.389E-18 1.112E-17 5.56E-14 7.339E-14 2.335E-10 1.890E-10

>48 6.389E-18 1.056E-17 5.56E-14 6.060E-14 2.335E-10 1.668E-10

>100 6.389E-18 1.390E-17 5.56E-14 5.699E-14 2.335E-10 1.612E-10

>250 6.389E-18 1.446E-17 5.56E-14 5.588E-14 2.335E-10 1.557E-10

>500 6.389E-18 9.730E-18 5.56E-14 5.560E-14 2.335E-10 1.251E-10

>720 6.389E-18 6.394E-18 5.56E-14 5.560E-14 2.335E-10 1.056E-10 Units in Ci hr units in Ci hr units in Ci hr sec ml cpm sec ml cpm sec ml R/hr.8 is the correlation factor per Reference 2.13 x hr x

Ci 3600 sec 1E6 pCi NOTE:

Reference 2.14.

If Time Since Trip is > 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and EMF53A or EMF53B is less than or equal to 150 R/hr, add 150 R/hr to reading.

DUKE POWER COMPANY CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.9 CONTAINMENT LEAKAGE RATE VERSUS PRESSURE PSIG mi/hr

>0

  • 2.081E5

>2 4.536E5

>4 8.316E5

>8 1.397E6

>10 1.591E6

>11 1.663E6

>12 1.713E6

>13 1.764E6

>14 1.800E6

>15 1.836E6.9 is the realistic leakage rate (m'/sec) per Reference 2.12 x 1E6 ml/m 3 x 3600 sec/hr.

  • 2.081E5 ml/hr is derived as follows:

2.081E5 ml = 0.017 %/day x 3.4E-3 m3 -day x 1E6 ml x 3600 sec hr

%-sec m

hr where:

0.017 is determined from containment leakage rate vs pressure curve from Reference 2.13 for an assumed 1 psig.

3.4E-3 is from Reference 2.12.

DUKE POWER COMPANY.

CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.10 CONTAINMENT LEAKAGE RATE VERSUS PRESSURE AND SIZE OPENING For 1" diameter opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 2.209E8

>5.0 3.908E8

>12.5 5.862E8

>2.50 2.889E8

>7.5 4.588E8

>15.0 6.287E8

>3.75 3.483E8

>10.0 5.268E8 For 2" diameter opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 8.496E8

>5.0 1.512E9

>12.5 2.243E9

>2.50 1.121E9

>7.5 1.784E9

>15.0 2.464E9

>3.75 1.342E9

>10.0 2.022E9 For 4" diameter opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 3.144E9

>5.0 5.692E9

>12.5 8.496E9

>2.50 4.248E9

>7.5 6.797E9

>15.0 9.176E9

>3.75 5.098E9

>10.0 7.731E9 For 6" diameter opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 7.137E9

>5.0 1.291E10 >12.5 1.937E10

>2.50 9.516E9

>7.5 1.529E10 >15.0 2.124E10

>3.75 1.138E10

>10.0 1.716E10 For 8" diameter opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 1.257E10

>5.0 2.243E10 >12.5 3.381E10

>2.50 1.648E10

>7.5 2.634E10 >15.0 3.568E10

>3.75 1.971E10

>10.0 3.042E10 For 12" diameter opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 2.719E10

>5.0 5.012E10 >12.5 7.476E10

>2.50 3.738E10

>7.5 5.947E10 >15.0 8.156E10

>3.75 4.452E10

>10.0 6.712E10 For 18" diameter opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 5.522E10

>5.0 1.003E11 >12.5 1.529E11

>2.50 7.476E10

>7.5 1.189E11

>15.0 1.665E11

>3.75 8.836E10

>10.0 1.351E11

EDA-2 ENCLOSURE 5.10 Page 2 of 2 For 34" diameter opening PSIG ml/hr PSIG mI/hr PSIG ml/hr

>1.25 1.869E11 >5.0 3.398E11

>12.5 5.132E11

>2.50 2.583E11 >7.5 4.078E11 >15.0 5.607E11

>3.75 3.093E11 >10.0 4.588E11 For Personnel Hatch opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 2.379E12

>5.0 4.690E12 >12.5 6.967E12

>2.50 3.398E12 >7.5 5.573E12 >15.0 7.646E12

>3.75 4.111E12 >10.0 6.372E12 For Equipment Hatch opening PSIG ml/hr PSIG ml/hr PSIG ml/hr

>1.25 1.121E13

>5.0 2.022E13

>12.5 3.059E13

>2.50 1.478E13

>7.5 2.379E13 >15.0 3.398E13

>3.75 1.767E13 >10.0 2.719E13

  • Enclosure 5.10 is the containment leakage for an opening size in standard cubic feet per min (scfm) x 2.83E4 ml/ft3 x 60 min/hr.

DUKE POWER COMPANY CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.11 SOURCE TERM ASSESSMENT - UNIT VENT Report Reactor Trip _____

_/

Projection based on data on

_/

(Date/Time)

(Date/Time)

Calculations based on Melted Core LOCA CFM =_______

ft'/min NOBLE GAS based on (check one) o EMF36(L) if < 1E7 cpm 0 EMF36(H1) if > 100 cpm a EMF54 if 36(H) is offscale EMF CF CFM QNG cpm or R/hr x

x ft 3

=

Ci (Encl. 5.12) min sec based on Unit Vent Sample pCi/ml x

4.72E-4 Ci min ml x

ft 3

=

Ci sec ft3 pCi min sec IODINE based on QNG QI Ci x

1131 eqv./Xel33 eqv.

=_

Ci sec ratio (Encl. 5.6) sec based on CFM EMF37 ACPM x 1.33E-13 Ci min min x

ft 3

=

Ci Amin sec ft3 cpm min sec based on Unit Vent Sample pCi/ml x 4.72E-4 Ci min ml x

ft 3

=

Ci sec ft3 pCi min sec a Emergency a Drill Prepared by:

DUKE PO COMPANY ENCL 5.12 CATAWBA UNIT VENT NOB GAS CORRECTION FACTOR Time Since EMF36(L)

EMF36(H)

EMF54 Trip (hours) based on based on based on Melted Core Melted Core Melted Core

>0 1.133E-10 2.426E-7 1.887E-3

>2 7.552E-11 1.704E-7 1.179E-3

>4 5.192E-11 2.091E-7 9.905E-4

>8 3.587E-11 2.030E-7 6.367E-4

>24 1.888E-11 1.246E-7 2.931E-4

>48 1.794E-11 1.029E-7 2.405E-4

>100 2.360E-11 9.676E-8 2.358E-4

>250 2.454E-11 9.487E-8 2.358E-4

>500 1.652E-11 9.440E-8 2.358E-4

>720 1.086E-11 9.440E-8 2.358E-4 If accident is:

1.

Melted core use table.

2.

Melted core through charcoal use table.

3.

New Fuel Accident (less than 100 days old) use 2.358E-11 for EMF36(L), use 9.67E-8 for EMF36(H),

use 2.358E-4 for EMF54.

4.

All other accidents use 1.086E-11 for EMF36(L), use 9.44E-8 for EMF36(H), use 2.358E-4 for EMF54.

Units in Ci min units in Ci min units in Ci min sec ft 3 cpm sec ft3 cpm sec ft 3 R/hr.12 is the correlation factor per Reference 2.13 x 2.83E4 ml x

min x

Ci ft 60 sec 1E6 uCi

DUKE POWER COMPANY CATAWBA NUCLEAR STATION EDA-2 ENCLOSURE 5.13 INTEGRATED DOSE Duration (hrs)

AO B1 El Al C1 D1 F1 B2 A2 C2 D2 E2 F2 F3 A3 Instructions:

1)

Add the doses from previous releases to the projected release.

2)

Add the times of releases to the time of the projected release.