Docket Nos. 50-269, 50-270, 50-287
License Nos. DPR-38, DPR-47, DPR-55
Duke Power Company
ATTN:
Mr. M. S. Tuckman, Vice President
Nuclear Operations
P. 0. Box 1007
Charlotte, NC 28201-1007
Gentlemen:
SUBJECT:
INSPECTION REPORT NOS. 50-269/91-04, 50-270/91-04, AND 50-287/91-04
This refers to the inspection conducted by D. W. Jones of this office on
February 25-March 1, 1991.
The inspection included a review of activities
authorized for your Oconee facility.
At the conclusion of the inspection, the
findings were discussed with those members of your staff identified in .the
report.
Areas examined during the inspection are identified in the report.
Within
these areas, the inspection consisted of selective examinations of procedures
and representative records,
interviews with personnel,
and observation of
activities in progress.
Within the scope of the inspection,
no violations or deviations were
identified.
In accordance with 10 CFR 2.790(a),
a copy of this letter and its enclosure
will be placed in the NRC Public Document Room.
Should you have any questions concerning this letter, please contact us.
Sincerely,
NLSIGNED BY
Douglas M. Collins, Chief
Radiological Protection and
Emergency Preparedness Branch
Division of Radiation Safety
and Safeguards
Enclosure:
NRC Inspection Report
cc w/encl:
(See page 2)
9 1l04100240 1040
PDR! ADCK00026
Duke Power Company
2
cc w/encl:
H. B. Barron
Station Manager
Oconee Nuclear Station
P. 0. Box 1439
Seneca, SC 29679
A. V. Carr, Esq
Duke Power Company
422 South Church Street
Charlotte, NC 28242-0001
County Supervisor of Oconee County
Walhalla, SC 29621
Robert B. Borsum
Babcock.and Wilcox Company
Nuclear Power Generation Division
Suite 525, 1700 Rockville Pike
Rockville, MD 20852
J. Michael McGarry, III, Esq.
Bishop, Cook, Purcell and Reynolds
1400 L Street, NW
Washington, D. C. 20005
Office of Intergovernmental Relations
116 West Jones Street
Raleigh, NC 27603
Heyward G. Shealy, Chief
Bureau of Radiological Health
South Carolina Department of Health
and Environmental Control
2600 Bull Street
Columbia, SC
29201
Manager, LIS
NUS Corporation
2650 McCormick Drive
Clearwater, FL
34619-1035
Stephen Benesole
Duke Power Company
P. 0. Box 1007
Charlotte, NC
28201-1007
cc w/encl: (Cont'd on page 3)
Duke Power Company
3
(cc w/encl:
cont'd)
R. L. Gill
Nuclear Production Department
Duke Power Company
P. 0. Box 1007
Charlotte, NC 28201-1007
Karen E. Long
Assistant Attorney General
N. C. Department of Justice
P. 0. Box 629
Raleigh, NC 27602
H. B. Tucker
Senior Vice President-Nuclear
Duke Power Company
P. 0. Box 1007
Charlotte, NC
28201-1007
bcc w/encl:
L. Wiens, NRR
W. Miller, RH
.
.A.
Herdt, RH
- U<cument Control Desk
NRC Resident Inspector
U.S. Nuclear Regulatory Commission
Route 2, Box 610
Seneca, SC 29678
RII:DRSS
RII:DRSS
RII:DRP
DJ
TD4 ker
ABe isle
( )
3/V/91
3 /4/V91