MONTHYEARRS-14-312, Supplemental Response to Request for Additional Information Regarding Fukushima Lessons Learned - Flood Hazard Reevaluation Report2014-11-0303 November 2014 Supplemental Response to Request for Additional Information Regarding Fukushima Lessons Learned - Flood Hazard Reevaluation Report Project stage: Supplement RS-15-064, Response to March 12, 2012, Request for Information Enclosure 2, Recommendation 2.1, Flooding, Required Response 2, Flood Hazard Reevaluation Report2015-03-12012 March 2015 Response to March 12, 2012, Request for Information Enclosure 2, Recommendation 2.1, Flooding, Required Response 2, Flood Hazard Reevaluation Report Project stage: Request ML15093A3112015-03-16016 March 2015 NRR E-mail Capture - Request for Additional Information: Clinton Flooding Hazard Reevaluation Report Project stage: RAI RS-15-110, Response to Request for Additional Information Regarding Fukushima Lessons Learned - Flood Hazard Reevaluation Report2015-05-0505 May 2015 Response to Request for Additional Information Regarding Fukushima Lessons Learned - Flood Hazard Reevaluation Report Project stage: Response to RAI ML15148A2862015-07-21021 July 2015 Nuclear Regulatory Commission Plan for the Audit of Exelon Generation Company, LLCs Flood Hazard Reevaluation Report Submittal Relating to the Near-Term Task Force Recommendation 2.1 -Flooding Project stage: Other ML15219A6452015-09-0303 September 2015 Tables 1 and 2 Project stage: Other ML15212A0102015-09-0303 September 2015 Interim Staff Response to Reevaluated Flood Hazards Submitted in Response to 10 CFR 50.54(f) Information Request - Flood-Causing Mechanism Reevaluation Project stage: Other ML15212A7272015-09-0404 September 2015 Interim Staff Response to Reevaluated Flood Hazards Submitted in Response to 10 CFR 50.54(f) Information Request Flood-Causing Mechanism Reevaluation Project stage: Other ML15219A6672015-09-0404 September 2015 Tables 1 and 2 Project stage: Request ML15279A1342015-10-27027 October 2015 Staff Assessment of Response to 10 CFR 50.54(f) Information Request-Flood-Causing Mechanism Reevaluation Project stage: Other ML15321A0342015-11-18018 November 2015 Correction to Staff Assessment of Response to Request for Information Pursuant to 10 CFR 50.54(f)-Flood Causing Mechanisms Reevaluation Project stage: RAI RS-16-055, Mitigating Strategies Flood Hazard Assessment (Msfha) Submittal2016-03-24024 March 2016 Mitigating Strategies Flood Hazard Assessment (Msfha) Submittal Project stage: Other 2015-03-16
[Table View] |
Text
Clinton 1 Table 1. Current Design Basis Flood Hazards for Use in the MSA Mechanism Stillwater Elevation Waves/
Runup Reference Design Basis Hazard Elevation Note: Reported values are rounded to the nearest one-tenth of a foot.
Local Intense Precipitation Local Intense Precipitation and Associated Drainage 736.8 ft MSL Not applicable 736.8 ft MSL FHRR Section 2.2.1 and Table 4.0.2 Failure of Dams and Onsite Water Control/Storage Structures No impact on the site identified No impact on the site identified No impact on the site identified FHRR Section 2.2.3 Streams and Rivers No impact on the site identified No impact on the site identified No impact on the site identified FHRR Section 2.2.2 Storm Surge Probable maximum flooding on cooling pond No impact on the site identified No impact on the site identified No impact on the site identified FHRR Section 2.2.5 Seiche No impact on the site identified No impact on the site identified No impact on the site identified FHRR Section 2.2.5 Tsunami No impact on the site identified No impact on the site identified No impact on the site identified FHRR Section 2.2.6 Ice-Induced Flooding No impact on the site identified No impact on the site identified No impact on the site identified FHRR Section 2.2.7 Channel Migrations/Diversions No impact on the site identified No impact on the site identified No impact on the site identified FHRR Section 2.2.8