ISFSI - General License 30-day Cask Registration Notification and Thermal Performance Assessment
ML15216A370
Person / Time
Site: 07201004, Nine Mile Point  
(DPR-063, NPF-069)
Issue date: 07/28/2015
From: Moore D
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
NMP1L 3037
Download: ML15216A370 (2)


Text

... Exet.on Generation NMP1 L 3037 10 CFR 72.212(b)(2)

July 28, 2015 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Nine Mile Point Nuclear Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-63 and NPF-69 Docket Nos. 50-220 and 50-410 Nine Mile Point Nuclear Station Independent Spent Fuel Storage Installation General License Docket No. 72-1036

SUBJECT:

General License 30-day Cask Registration Notification and Thermal Performance Assessment Pursuant to the requirements of 10 CFR 72.212(b)(2), this letter provides the information to register the use of two approved spent fuel storage casks at the Nine Mile Point Nuclear Station (NMPNS) Independent Spent Fuel Storage Installation (ISFSI).

Licensee's Name:

Address:

Reactor License Numbers:

Docket Numbers:

Person Responsible for Providing additional information:

Cask Certificate Number:

Certificate Amendment Number:

Cask Model Number:

Cask Identification Numbers:

Nine Mile Point Nuclear Station, LLC P0 Box 63 Lycoming, NY 13093 DPR-63 and NPF-69 50-220, 50-410 and 72-1036 Mr. Kenneth J. Kristensen 315-349-2069 1004 10 NUHOMS-61 BTH NMP-61 BTH-1 -A-2-023, loaded July 2, 2015 NMP-61BTH-1-A-2-024, loaded July 9, 2015 The Technical Specifications (TS) for Certificate of Compliance (CoC) No. 1004, Amendment No. 10, §1.1.7 "Special Requirements for First System in Place", requires the results of the temperature measurements of the first Dry Shielded Canister (DSC) placed in service be submitted to the NRC for evaluation and assessment. Additionally, this section of TS requires subsequent users of the system to report heat loads higher than the first user. The first user of the NUHOMS CoC No. 1004, Duke Energy, submitted the heat transfer characteristics for an 18.95 kilowatt (kW) Dry Shielded Canister (DSC) in a letter to the NRC, from Duke Energy, "Cask Certificate of Compliance, Docket No.: 72-1 004, 30-day Report for Higher Canister Heat Loading per General Requirement Section 1.1.7," dated August 8, 2007 (ML072340622). The

30 Day Cask Registration July 28, 2015 Page 2 first DSC loaded at NMPNS had a heat load of 7.30 kW, as reported in our letter dated October 17, 2012.

A summary of the thermal performance of the 23rd and 24th DSCs in place at the NMPNS ISFSI is submitted for your information.

Horizontal Storage Module (HSM) Model:

HSM Identification Number:

7DF Cask:

NMI Calculated Heat Load:

11.E Calculated AT:

58 c Actual AT (Note 1):

36.,C HSM Identification Number:

7DF Cask:

NMI Calculated Heat Load:

11.E Calculated AT:

58 c Actual AT (Note 1):

40..*

NUHOMS Model 102

-S-HSM002C P-61 BTH-1 -A-2-023 3152 kW degrees F Sdegrees F

-S-HSM002D P-61 BTH-1 -A-2-024 5685 kW degrees F 5 degrees F Note 1: The actual AT represents the measured AT obtained during equilibrium conditions.

Equilibrium conditions were achieved when the daily temperature change observed was less than 6 degrees F over three consecutive days.

This letter contains no NRC commitments.

Should you have any questions regarding the information in this submittal, please contact Ken Kristensen at (315) 349-2069.

Sincerely, Dennis M. Moore Regulatory Assurance Manager, Nine Mile Point Nuclear Station Exelon Generation Company, LLC DMM/KJK cc: