Text
Structural Integrity Associates, lcy File No.: 1400669.310 Project No.: 1400669 CALCULATION PACKAGE Quality Program Type: [ Nuclear [] Commercial PROJECT NAME:
Palisades Flaw Readiness Program for 1R24 NDE Inspection CONTRACT NO.:
10426669 CLIENT:
PLANT:
Entergy Nuclear Operations, Inc.
Palisades Nuclear Plant CALCULATION TITLE:
Finite Element Model for Hot Leg Drain Nozzle Document Affected Project Manager Preparer(s) &
Revision Pages Revision Description Approval Checker(s)
Signature & Date Signatures & Date 01
- 20 Initial Issue Preparer:
A A-2 Computer Files Norman Eng NE 03/09/2015 Minji Fong MF 03/09/2015 Checkers:
Charles Fourcade CJF 03/09/2015 Gole Mukhim GSM 03/09/2015 Page 1 of 20 F0306-01R2
tjjSbuftirhI Iatuflr Assocades, 6ncY Table of Contents 1.0 OBJECTIVE.........................................................................................................
4 2.0 TECHNICAL APPROACH....................................................................................
4 3.0 ASSUM PTIONS / DESIGN INPUTS.......................................................................
4 4.0 FINITE ELEM ENT M ODEL..................................................................................
5 4.1 Element Type and M esh................................................................................
5 4.2 M aterials......................................................................................................
5 4.2.1 Creep Properties................................................................................................
5 4.3 Loads and Boundary Conditions.................................................................
6
5.0 CONCLUSION
S......................................................................................................
6
6.0 REFERENCES
7 APPENDIX A COM PUTER FILES LISTING................................................................
A-1 File No.: 1400669.310 Revision: 0 Page 2 of 20 F0306-01R2
5S&'fwbu ral IueunrIy Associats, Incr List of Tables Table 1: Component Materials............................................................................................
8 Table 2: Elastic Properties for SA-516 Grade 70 (< 4" Thick)..........................................
9 Table 3: Stress-Strain Curves for SA-516 Grade 70 (< 4" Thick)....................................
10 Table 4: Elastic Properties for ER308L..................................................................................
11 Table 5: Stress-Strain Curves for ER308L........................................................................
12 Table 6: Elastic Properties for Alloy 600..........................................................................
13 Table 7: Stress-Strain Curves for Alloy 600......................................................................
14 Table 8: Elastic Properties for Alloy 182..........................................................................
15 Table 9: Stress-Strain Curves for Alloy 182......................................................................
16 Table 10: C reep Properties.................................................................................................
17 List of Figures Figure 1. Finite Element Model Dimensions......................................................................
18 Figure 2. Components Included in the Finite Element Model..........................................
19 Figure 3. Isometric View of the Finite Element Model...................................................
20 File No.: 1400669.310 Revision: 0 Page 3 of 20 F0306-01R2
Vj~snat~umraInhterily Associaes, Ina?
1.0 OBJECTIVE The objective of this calculation package is to document the development of a finite element model (FEM) for the reactor hot leg drain nozzle at the Palisades Nuclear Plant, which will be used to perform residual and operational-based fracture mechanics analyses to support a subsequent fracture mechanics evaluation as part of a flaw readiness program.
2.0 TECHNICAL APPROACH One three-dimensional (3-D) finite element model is developed using the ANSYS finite element analysis software package [1]. The area of interest is the nozzle-to-pipe weld. The model uses elastic-plastic material properties intended for weld residual stress analysis, and elastic material properties for linear elastic analyses.
3.0 ASSUMPTIONS / DESIGN INPUTS The dimensions and material types to develop the finite element model are provided in References 2 and 3 and summarized in Figure 1. The material properties are obtained from References 4 and 5. A number of assumptions were made during development of the finite element model, which are listed as follows:
" The drain nozzle is modeled as a straight pipe without the nozzle transition since the area of interest is the nozzle-to-hot leg piping weld which is away from the nozzle-to-safe end transition.
- The axial length of the modeled portion of the hot leg piping is arbitrarily set at 36 inches, which is sufficiently long enough to negate possible end effects in the region of interest.
" The ID patch weld is added after removal of the backing ring according to the weld procedure mentioned in the drawing [2]. The same material of the nozzle-to-pipe weld is used for the ID patch weld.
File No.: 1400669.310 Revision: 0 Page 4 of 20 F0306-01R2
jS&WkIfraI I0grlty Assodaats, Inc.
4.0 FINITE ELEMENT MODEL The model includes a local portion of the hot leg pipe and cladding, the drain nozzle, and the nozzle-to-pipe weld, including the ID patch weld, as shown in Figure 2. As shown in the figure, a single 90' quadrant of the drain nozzle penetration is modeled due to geometric symmetry. The included portion of the hot leg piping measures 36 inches longitudinally and 180 degree circumferentially. The mesh of the finite element model is shown in Figure 3.
4.1 Element Type and Mesh The 8-node solid element (SOLID185) in ANSYS [1] is used for the model. SOLID185 elements support material plasticity which is suitable for residual stress and elastic plastic fracture mechanics (EPFM) analyses. The model contains adequate mesh refinement within the weld region to predict the residual stresses from welding.
4.2 Materials The material designation for the modeled components is listed in Table 1. The temperature dependent nonlinear material property values are provided in a separate calculation package [5], which are based on the 2001 Edition of the ASME Code with Addenda through 2003 [4]. The material properties are listed in Table 2 through Table 9.
4.2.1 Creep Properties Since post weld heat treatment (PWHT) will be considered in the subsequent residual stress calculation, creep properties are required. In general, creep becomes significant at temperatures above 8007F; thus, creep behavior under 800'F will not be considered in this analysis.
There are two main categories of creep: primary and secondary. The primary creep addresses the creep characteristics for a short duration at the early stages of the creep regime, while the secondary creep accounts for the creep behavior for a long duration - usually more than 10,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />. Based on this definition, the PWHT falls within the primary creep characteristics. However, primary creep rates for materials are difficult to obtain, so the conservative secondary creep rates are used since primary creep rate is typically an order of magnitude higher than that for secondary creep.
In general, the primary creep rate for the materials is governed by the equation:
dc = A0-"
dt The creep data for the SA-516 Grade 70 hot leg material is based on carbon steel material [6]. The creep data for the Alloy 82/182 and ER308L weld metals are not available, so the creep properties for their base metals are used instead. The creep data for Type 304 (for ER308L) is provided in the same File No.: 1400669.310 Page 5 of 20 Revision: 0 F0306-01R2
j shniuruI hI egnify Associates, Inc.
reference document as the carbon steel [6], while the creep data for the Alloy 600 (for Alloy 82/182) is provided in a separate reference document [7]. All the creep strengths, a, are provided at two creep rates
[6, 7] for each temperature point.
When creep strength is provided at two creep rates at the same temperature point, as listed in Table 10, then A and n can be calculated as follows, where subscripts 1 and 2 refer to the creep data sets 1 and 2:
dcI
°
--= = Ao-"
dt 8i=
AO-1 1 ; 62 =AO-2n
._C_=
O-__
E j2 n2 E2 2
l I]
In 2 I 01 6T1 4.3 Loads and Boundary Conditions No loads or boundary conditions of any kind are included in the finite element model in this calculation.
Specific loads and boundary conditions, appropriate to the specific analyses, will be applied in the subsequent residual and thermal/mechanical stress calculation packages.
5.0 CONCLUSION
S A finite element model of the hot leg drain nozzle is developed. The model will be used in subsequent weld residual stress analyses and fracture mechanics analyses. The necessary ANSYS input file names are listed in Appendix A.
File No.: 1400669.310 Revision: 0 Page 6 of 20 F0306-01R2
CjSbwkral late Associates, IncO
6.0 REFERENCES
- 1. ANSYS Mechanical APDL and PrepPost, Release 14.5 (w/ Service Pack 1), ANSYS, Inc.,
September 2012.
- 2. Drawing No. VEN-M1-D, Sheet 108, Rev. 10, "Nozzle Details," SI File No. 1400669.202.
- 3. Drawing No. VEN-M1-D, Sheet 106, Rev. 10, "Piping Assembly & Details," SI File No.
1400669.202.
- 4. ASME Boiler and Pressure Vessel Code,Section II, Part D - Properties, 2001 Edition with Addenda through 2003.
- 5. SI Calculation No. 0800777.307, Rev.5, "Material Properties for Residual Stress Analyses, Including MISO Properties Up To Material Flow Stress."
- 6. "Steels for Elevated Temperature Service," United States Steel Co., 1949.
- 7. Publication SMC-027, "Inconel Alloy 600," Special Metals Corp., 2004, SI File No.
0800777.211.
- 8. Palisades Design Input Record, "Palisades Alloy 600 Flaw Evaluation DIR 3-4-15 Rev 1.pdf," SI File No. 1400669.201.
File No.: 1400669.310 Revision: 0 Page 7 of 20 F0306-01R2
VJSWAJcrlI Ilifgrily AssocaEMs, Inc.
Table 1: Component Materials Component Material References Hot Leg Piping SA-516 Grade 70
[8]
Pipe Cladding ER308L (1)
[3]
Drain Nozzle
- SB-166 (N06600, Alloy 600) (2)
[2]
Drain Nozzle-to-Pipe Weld Alloy 182
[8]
ID Patch Weld Alloy 182
[8]
Notes:
- 1. The material properties are based on equivalent Type 304 base material.
- 2. Alloy SB-166 is assumed to have the same material properties as Alloy 600.
File No.: 1400669.310 Revision: 0 Page 8 of 20 F0306-01R2
V oStwhira Iatrify Assadoits, Inc.
Table 2: Elastic Properties for SA-516 Grade 70 (5 4" Thick)
Temperature Young's Mean Thermal Thermal Modulus Expansion Conductivity (2) Specific Heat (2)
(0F)
(x10 3 ksi)
(xlO-6 in/in/°F)
(Btu/min-in-°F)
(Btu/Ib-'F) 70 29.5 6.4 0.0488 0.103 500 27.3 7.3 0.0410 0.128 700 25.5 7.6 0.0369 0.138 1100 18.0 8.2 0.0290 0.171 1500 5.0 8.6 0.0218 0.198 2500 0.1 9.5 0.0014 0.204 2500.1 0.0 Notes:
- 1. All values per [5].
- 2. Density (p) = 0.283 lb/in3 [5], assumed temperature independent.
- 3. Poisson's Ratio (u) = 0.3 [5], assumed temperature independent.
File No.: 1400669.310 Revision: 0 Page 9 of 20 F0306-01R2
noworur Ifegrly Associates, Inc Table 3: Stress-Strain Curves for SA-516 Grade 70 (5 4" Thick)
Temperature Strain Stress
('F)
(in/in)
(ksi) 0.00128814 38.000 0.00187809 42.000 70 0.00257329 46.000 0.00381110 50.000 0.00600383 54.000 0.00113553 31.000 0.00142679 35.875 500 0.00183954 40.750 0.00261139 45.625 0.00415246 50.500 0.00106667 27.200 0.00132412 32.550 700 0.00166876 37.900 0.00228121 43.250 0.00354341 48.600 0.00116667 21.000 0.05116163 22.125 1100 0.05915444 23.250 0.06794123 24.375 0.07755935 25.500 0.00300000 15.000 0.16717493 15.125 1500 0.16992011 15.250 0.17268761 15.375 0.17547742 15.500 0.01000000 1.000 0.10961239 1.125 2500(2) 0.12781277 1.250 0.14689940 1.375 0.16683167 1.500 Notes:
- 1. All values per [5].
- 2. Values at 2500'F assumed arbitrarily small values for convergence stability.
File No.: 1400669.310 Revision: 0 Page 10 of 20 F0306-01R2
$SMLwM*0rl lategfify Associates, Inc.
Table 4: Elastic Properties for ER308L Temperature Young's Mean Thermal Thermal Modulus Expansion Conductivity (2) Specific Heat (2)
(0F)
(x10 3 ksi)
(xl0-6 in/in/0 F)
(Btu/min-in-°F)
(Btu/lb'°F) 70 28.3 8.5 0.0119 0.116 500 25.8 9.7 0.0151 0.131 700 24.8 10.0 0.0164 0.135 1100 22.1 10.5 0.0189 0.140 1500 18.1 10.8 0.0213 0.145 2500 0.1 11.5 0.0292 0.159 2500.1 0.0 Notes:
- 1. All values per [5].
- 2. Density (p) = 0.283 lb/in3 [5], assumed temperature independent.
- 3. Poisson's Ratio (u) = 0.3 [5], assumed temperature independent.
File No.: 1400669.310 Revision: 0 Page 11 of 20 F0306-01R2
$stioralI Intgrity Associates, IncO Table 5: Stress-Strain Curves for ER308L Temperature Strain Stress
(°F)
(in/in)
(ksi) 0.00203180 57.500 0.02471351 61.563 70 0.03107296 65.625 0.03861377 69.688 0.04747167 73.750 0.00140089 36.143 0.00714793 40.250 500 0.01065407 44.357 0.01558289 48.464 0.02233857 52.571 0.00132488 32.857 0.00477547 37.125 700 0.00743595 41.393 0.01143777 45.661 0.01727192 49.929 0.00121913 26.943 0.00264833 30.138 1100 0.00404100 33.332 0.00634529 36.527 0.01005286 39.721 0.00117995 21.357 0.05352064 21.563 1500 0.05610492 21.768 0.05878975 21.973 0.06157807 22.179 0.01000000 1.000 0.10961239 1.125 2500(2) 0.12781277 1.250 0.14689940 1.375 0.16683167 1.500 Notes:
- 1. All values per [5].
- 2. Values at 2500'F assumed arbitrarily small values for convergence stability.
File No.: 1400669.310 Revision: 0 Page 12 of 20 F0306-01R2
jSb uraItl lfgrt* Associats, Inc.
Table 6: Elastic Properties for Alloy 600 Temperature Young's Mean Thermal Thermal Modulus Expansion Conductivity (2)
Specific Heat (2)
(OF)
(xl03 ksi)
(x10-6 in/in/IF)
(Btu/min-in-°F)
(Btu/lb-0 F) 70 31.0 6.8 0.0119 0.108 500 29.0 7.6 0.0147 0.120 700 28.2 7.9 0.0161 0.125 1100 25.9 8.4 0.0192 0.139 1500 23.1 9.0 0.0222 0.148 2500 0.1 10.0 0.0306 0.177 2500.1 0.0 Notes:
- 1. All values per [5].
- 2. Density (p) = 0.300 lb/in3 [5], assumed temperature independent.
- 3. Poisson's Ratio (u) = 0.29 [5], assumed temperature independent.
File No.: 1400669.310 Revision: 0 Page 13 of 20 F0306-01R2
l'a/ntegrlfy Assoad0s, Inc.a Table 7: Stress-Strain Curves for Alloy 600 Temperature Strain Stress
('F)
(in/in)
(ksi) 0.00157419 48.800 0.01658847 55.300 70 0.02343324 61.800 0.03212188 68.300 0.04291703 74.800 0.00152069 44.100 0.01539220 50.338 500 0.02210610 56.575 0.03072476 62.813 0.04153277 69.050 0.00152128 42.900 0.01634485 49.000 700 0.02334760 55.100 0.03227153 61.200 0.04338643 67.300 0.00155985 40.400 0.02275193 44.475 1100 0.03004563 48.550 0.03888203 52.625 0.04943592 56.700 0.00092641 21.400 0.08827666 22.475 1500 0.09785101 23.550 0.10796967 24.625 0.11863796 25.700 0.01000000 1.000 0.10961239 1.125 2500(2) 0.12781277 1.250 0.14689940 1.375 0.16683167 1.500 7IN otes:
- 1. All values per [5].
- 2. Values at 2500'F assumed arbitrarily small values for convergence stability.
File No.: 1400669.310 Revision: 0 Page 14 of 20 F0306-01R2
VjIs~ncfirahI Iturity Associaes, Inc.
Table 8: Elastic Properties for Alloy 182 Temperature Young's Mean Thermal Thermal Modulus Expansion Conductivity (2)
Specific Heat (2)
(OF)
(xl03 ksi)
(xl0-6 in/in/0F)
(Btu/min-in-0 F)
(Btu/lbF) 70 31.0 6.8 0.0119 0.108 500 29.0 7.6 0.0147 0.120 700 28.2 7.9 0.0161 0.125 1100 25.9 8.4 0.0192 0.139 1500 23.1 9.0 0.0222 0.148 2500 0.1 10.0 0.0306 0.177 2500.1 0.0 Notes:
- 1. All values per [5].
- 2. Density (p) = 0.300 lb/in 3 [5], assumed temperature independent.
- 3. Poisson's Ratio (u) = 0.29 [5], assumed temperature independent.
File No.: 1400669.310 Revision: 0 Page 15 of 20 F0306-01R2
owinural Integrify Associas, IncO Table 9: Stress-Strain Curves for Alloy 182 Temperature Strain Stress
('F)
(in/in)
(ksi) 0.00179032 55.500 0.03456710 60.113 70 0.04292837 64.725 0.05257245 69.338 0.06359421 73.950 0.00164483 47.700 0.02976152 52.313 500 0.03809895 56.925 0.04790379 61.538 0.05929946 66.150 0.00159574 45.000 0.02849157 49.538 700 0.03680454 54.075 0.04663682 58.613 0.05812078 63.150 0.00159073 41.200 0.03568855 44.488 1100 0.04402702 47.775 0.05360088 51.063 0.06449835 54.350 0.00106494 24.600 0.11812735 25.325 1500 0.12540227 26.050 0.13290814 26.775 0.14064577 27.500 0.01000000 1.000 0.10961239 1.125 2500(2) 0.12781277 1.250 0.14689940 1.375 0.16683167 1.500 Notes:
- 1.
All values per [5].
- 2.
Values at 2500'F assumed arbitrarily small values for convergence stability.
File No.: 1400669.310 Revision: 0 Page 16 of 20 F0306-01R2
VjjSiuchirw lit Hrit Associts, InM@
Table 10: Creep Properties Material Temperature Creep Strength (ksi)
A (OF) al (0.0001%/hr) 62 (0.00001%/hr)
(ksi/hr) 800 19.0 12.4 1.26E-13 5.40 SA-516 Gr. 70 900 9.0 6.7 3.59E-14 7.80 (Based on carbon steel) 1000 3.5 2.8 2.43E-12 10.32 Per [6]
1100 1.4 0.8 2.50E-07 4.11 800 33.4 25.0 7.73E-19 7.95 ER308L 900 24.0 17.6 5.67E-17 7.42 (Based on Type 304) 1000 17.6 11.5 1.82E-13 5.41 Per [6]
1100 11.5 7.1 8.62E-12 4.77 Alloy 600 800 40.0 30.0 1.50E-19 8.00 Alloy 182 900 28.0 18.0 2.87E-14 5.21 (Based on 1000 12.5 6.1 3.02E-10 3.21 Alloy 600)
Per [7]
1100 6.8 3.4 1.72E-09 3.32 File No.: 1400669.310 Revision: 0 Page 17 of 20 F0306-01R2
vjsbend"u hawfy Associates IWO~
4 9116" O.D.
2 5116" I.D.
6 3/16" O.D.
36"1 From Center Line 10 15/11I 11/4" R f7 112° 3
H4I'1*4sO T
i" 1T 41518" 1/4" 49 5/8" 41 5/8O.D.
I.D, Figure 1. Finite Element Model Dimensions Note: Dimensions obtained from [2, 31.
File No.: 1400669.310 Revision: 0 Page 18 of 20 F0306-01R2
C aw"mfuu Mbpffy Associates, kk?
ANSYS R 14.5
\\ID Patch Weld Figure 2. Components Included in the Finite Element Model File No.: 1400669.310 Revision: 0 Page 19 of 20 F0306-01R2
C an"oiuu hd**N Associates, /nr.G Figure 3. Isometric View of the Finite Element Model (Nozzle weld detail shown in bottom right comer)
File No.: 1400669.310 Revision: 0 Page 20 of 20 F0306-01R2
- SVebuuI k As s, nr.° APPENDIX A COMPUTER FILES LISTING File No.: 1400669.310 Revision: 0 Page A-I of A-2 F0306-01R2
Can" uOW hipf AssOCiat, W~
File Name Description PalisadesHLDrain.INP Input file to create base model geometry MProp_MISO.INP Elastic-plastic Material properties inputs File No.: 1400669.310 Page A-2 of A-2 Revision: 0 F0306-OIR2