Text

10 CFR 72.212(b)(2)

Palo Verde Nuclear Generating Station 5801 S. Wintersburg Road 102-07066-TN W/JR Tonopah, AZ 85354 June 23, 2015 AT-rN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Palo Verde Nuclear Generating Station (PVNGS) Unit 1 and Independent Spent Fuel Storage Installation (ISFSI)

Docket Nos. STN 50-528 and 72-44 Registration of Dry Spent Fuel Transportable Storage Canister Identification No. AMZDFX131

Dear Sirs:

In accordance with 10 CFR 72.212(b)(2), Arizona Public Service Company (APS) is registering the use of a dry spent fuel storage cask to store spent fuel under a 10 CFR Part 72 general license at the PVNGS ISFSI. The information below is provided for transportable storage canister (TSC) identification no. AMZDFX131, used to store spent fuel within vertical concrete cask (VCC) no. AM7DNE131, beginning on June 19, 2015.

Licensee's Name:

Arizona Public Service Company (APS) is the operating agent for PVNGS.

PVNGS Units 1, 2, and 3 have seven owners who are licensees. The owners/licensees are APS, Salt River Project Agricultural Improvement and Power District, El Paso Electric Company, Southern California Edison Company, Public Service Company of New Mexico, Los Angeles Department of Water and Power, and Southern California Public Power Authority. As specified in the PVNGS renewed operating licenses, APS is authorized to act as agent for the PVNGS licensees and has exclusive responsibility and control over the physical construction, operation and maintenance of the facility.

A memnber of the STARS (Strategic Teaming and Resource Sharing) Alliance

Caliaway, Diablo Canyon *Palo Verde
  • Wolf. Creek

102-07066-TN W/J R ATTIN: Document Control Desk U.S. Nuclear Regulatory Commission Registration of Dry Spent Fuel Storage Canister - Identification No. AMZDFX131 Page 2 Licensee's Address:

Arizona Public Service Company P.O. Box 52034 Phoenix, AZ 85072-2034 Reactor:

Palo Verde Nuclear Generating Station Unit 1 License Number:

NPF-41 Docket Numbers:

Contact Name and

Title:

Cask Certificate No.:

Cask Model No.:

Cask Identification Nos.:

STN 50-528 and 72-44 Thomas N. Weber, Nuclear Regulatory Affairs Department Leader Certificate of Compliance No. 1015, Amendment No. 5, January 12, 2009 NAC-UMS Transportable Storage Canister (TSC) Identification No.

AMZDFX131 Vertical Concrete Cask (VCC) Identification No.

AMZDNE131 No commitments are being made to the NRC by this letter. Should you need further information regarding this submittal, please contact me at (623) 393-5764.

Sincerely, Thomas N. Weber Nuclear Regulatory Affairs Department Leader TNW/J R/a kf CC:

M. L. Dapas M. M. Watford C. A. Peabody NRC Region IV Regional Administrator NRC NRR Project Manager for PVNGS NRC Senior Resident Inspector for PVNGS