MONTHYEARML22294A1892022-11-0808 November 2022 Federal Register Notice - Notice of Intent to Prepare EIS and to Conduct EIS Scoping for North Anna Power Station ML21222A1632021-08-19019 August 2021 Subsequent License Renewal Draft SEIS NOA FRN ML21153A2122021-07-0707 July 2021 Individual Notice of Consideration of Issuance of Amendment(S) to (Renewed) Facility Operating Licenses, Proposed No Significant Hazards Consideration Determination, Opportunity for Hearing (EPID L-2021-LLA-0082)FRN ML21153A2112021-07-0707 July 2021 Individual Notice of Consideration of Issuance of Amendment(S) to (Renewed) Facility Operating Licenses, Proposed No Significant Hazards Consideration Determination, Opportunity for Hearing (EPID L-2021-LLA-0082) LTR ML20274A1982020-10-19019 October 2020 Notice of Intent to Prepare an Environmental Impact Statement and Conduct Scoping Process (EPID No. L-2020-SLE-0000) - Federal Register Notice ML20252A0042020-09-23023 September 2020 Request for Relief Request Fifth 10-Year Interval ML20224A1052020-09-17017 September 2020 SLRA - Receipt and Availability Letter ML20177A6452020-07-15015 July 2020 FRN - Notice of Issuance of Multiple Exemptions Regarding Various Parts of 10 CFR Due to COVID-19 Impacts for June 2020 ML19169A2612019-07-31031 July 2019 Federal Register Notice: Virginia Electric and Power Company, Dominion Energy Kewaunee, Inc. and Dominion Nuclear Connecticut, Inc. North Anna ISFSI: Environmental Assessment and Finding of No Significant Impact; Issuance ML18173A1792018-08-0707 August 2018 OEDO-17-00070 - Notice of Issuance of Director'S Decision, 2.206 Petition for Emergency Enforcement Action Per 10 CFR 2.206 at Listed U.S. Reactors with Forged Components and Parts Manufactured at France'S AREVA-Le Creusot Forge and Japan C ML18036B1302018-02-12012 February 2018 Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing SUNSI and Order Imposing Procedures for Access to SUNSI - Publication Date: March 6, 20 ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) ML17312A6062018-01-29029 January 2018 Federal Register Notice for the Final Environmental Assessment for the North Anna ISFSI License Renewal NRC-2015-0237, Enclosufederal Register Notice-Notice of Issuance of Amendment Request to Materials License No. SNM-25072017-09-13013 September 2017 Enclosufederal Register Notice-Notice of Issuance of Amendment Request to Materials License No. SNM-2507 ML17236A2102017-09-13013 September 2017 Enclosufederal Register Notice-Notice of Issuance of Amendment Request to Materials License No. SNM-2507 ML17198A3292017-08-30030 August 2017 OEDO-17-00070 - Acknowledgement Letter, Paul Gunter, Beyond Nuclear, Petition for Emergency Enforcement Action Per 10 CFR 2.206 at Listed U.S. Reactors with Forged Components and Parts Manufactured at France'S AREVA-Le Creusot Forge and Jap ML17200A0652017-08-30030 August 2017 OEDO-17-00070 - Acknowledgement FRN, Paul Gunter, Beyond Nuclear, 2.206 Petition for Emergency Enforcement Action Per 10 CFR 2.206 at Listed U.S. Reactors with Forged Components and Parts Manufactured at France'S AREVA-Le Creusot Forge and ML16061A3012016-03-0202 March 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: March 15, 2016 ML15293A4542015-10-30030 October 2015 Revised Director'S Decision Letter (G20110757) NRC-2012-0258, Unit 2 - Federal Register Notice Director'S Decision 15-092015-10-30030 October 2015 Unit 2 - Federal Register Notice Director'S Decision 15-09 ML15293A4892015-10-30030 October 2015 Unit 2 - Federal Register Notice Director'S Decision 15-09 ML15176A6282015-08-21021 August 2015 G20110757 - Petition Federal Register Notice (Enclosure 2) ML15218A6252015-08-14014 August 2015 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 14, 2015 ML15148A3762015-06-0101 June 2015 Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Published June 9, 2015 ML14311A6242015-04-17017 April 2015 G20110757 - North Anna Proposed Director'S Decision ML13018A2392015-04-0808 April 2015 G20110171 - Letter to Petitioner Saporito on Proposed Director'S Decision Regarding 2.206 Petition Dated: March 12, 2011 NRC-2014-0917, Biweekly Sholly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 16, 20142014-09-0505 September 2014 Biweekly Sholly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 16, 2014 ML14247A1542014-09-0505 September 2014 Biweekly Sholly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 16, 2014 ML14233A2082014-08-22022 August 2014 Biweekly Sholly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 2, 2014 NRC-2014-0193, Biweekly Sholly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 2, 20142014-08-22022 August 2014 Biweekly Sholly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 2, 2014 NRC-2014-0121, Federal Register Notice: North Anna Power Station, Unit 2 - Withdrawal of an Amendment Request2014-05-0909 May 2014 Federal Register Notice: North Anna Power Station, Unit 2 - Withdrawal of an Amendment Request ML14114A6592014-05-0909 May 2014 Withdrawal of an Amendment Request ML14122A3042014-05-0909 May 2014 Federal Register Notice: North Anna Power Station, Unit 2 - Withdrawal of an Amendment Request ML13225A5572013-08-12012 August 2013 Rescission of Certain Security Orders Concerning Spent Nuclear Fuel in Transit ML13228A3992013-08-12012 August 2013 Letter to Holders of Independent Spent Fuel Storage Installation (ISFSI) Licenses Re Rescission of Certain Security Orders Concerning Spent Nuclear Fuel in Transit - Rin 3150-AI64 (NRC-2009-0163) EA-02-109 NRC-2013-0172, Units 1 and 2 - FRN - Environmental Assessment and Finding of No Significant Impact (TAC Nos. ME9753, ME9754, ME9755, and ME9756)2013-07-24024 July 2013 Units 1 and 2 - FRN - Environmental Assessment and Finding of No Significant Impact (TAC Nos. ME9753, ME9754, ME9755, and ME9756) ML13205A2192013-07-24024 July 2013 Environmental Assessment and Finding of No Significant Impact ML13205A2232013-07-24024 July 2013 FRN - Environmental Assessment and Finding of No Significant Impact ML12262A1602012-10-19019 October 2012 G20110757/EDATS:OEDO-2011-0701 - Federal Register Notice - Issuance of Partial Director'S Decision NRC-2012-0241, Units 1 and 2 - Federal Register Notice - Withdrawal of Amendment (TAC Nos. ME7814, ME7815, ME7816, and ME7817)2012-10-10010 October 2012 Units 1 and 2 - Federal Register Notice - Withdrawal of Amendment (TAC Nos. ME7814, ME7815, ME7816, and ME7817) ML12277A3662012-10-10010 October 2012 Withdrawal of Amendment ML12277A3732012-10-10010 October 2012 Federal Register Notice - Withdrawal of Amendment ML12094A2512012-04-27027 April 2012 G20110668/ EDATS: OEDO-2011-0622 - Federal Register Notice - Final Director'S Decision Under 10 CFR 2.206 Re North Anna Power Station, Unit Nos. 1 and 2 ML12104A1282012-04-12012 April 2012 Enclosufederal Register Notice (Notice of Availability of Exemption for Virginia Electric and Power Company, North Anna Power Station Independent Spent Fuel Storage Installation) ML12104A0822012-04-12012 April 2012 Enclosuexemption L. N. Hartz Letter Exemption from Parts of 10 CFR 72.212 - Storage of the Nuhoms Hd Dry Shielded Canisters at North Anna Power Station Independent Spent Fuel Storage Installation (TAC No. L24551) NRC-2012-0084, Enclosufederal Register Notice (Notice of Availability of Exemption for Virginia Electric and Power Company, North Anna Power Station Independent Spent Fuel Storage Installation)2012-04-12012 April 2012 Enclosufederal Register Notice (Notice of Availability of Exemption for Virginia Electric and Power Company, North Anna Power Station Independent Spent Fuel Storage Installation) ML12060A0902012-03-16016 March 2012 G20110757/EDATS: OEDO-2011-0701 - Acknowledgement Letter to Paul Gunter Re.: Request for Emergency Enforcement Action to Suspend and Restart and Operation of the North Anna Nuclear Generating Station, Units 1 and 2 ML12060A0912012-03-16016 March 2012 G20110757/EDATS: OEDO-2011-0701 - Federal Register Notice - Receipt of Request for Action Under 10 CFR 2.206 for North Anna Power Station, Unit Nos. 1 and 2 NRC-2012-0075, G20110757/EDATS: OEDO-2011-0701 - Federal Register Notice - Receipt of Request for Action Under 10 CFR 2.206 for North Anna Power Station, Unit Nos. 1 and 22012-03-16016 March 2012 G20110757/EDATS: OEDO-2011-0701 - Federal Register Notice - Receipt of Request for Action Under 10 CFR 2.206 for North Anna Power Station, Unit Nos. 1 and 2 NRC-2012-0067, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status2012-03-12012 March 2012 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately) - to All Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status 2022-11-08
[Table view] |
Text
[7590-01-P]
NUCLEAR REGULATORY COMMISSION
[Docket Nos. 50-338 and 50-339; NRC-2012-0258]
License Nos.: NPF-4 and NPF-7 North Anna Power Station, Units 1 and 2 Virginia Electric and Power Company AGENCY: Nuclear Regulatory Commission.
ACTION: Directors Decision under 10 CFR 2.206; issuance.
SUMMARY
- The U.S. Nuclear Regulatory Commission (NRC or the Commission) is giving notice that the Director of the Office of Nuclear Reactor Regulation has issued a final Directors Decision with regard to a petition dated October 20, 2011, filed by Paul Gunter et al, herein referred to as the petitioners.
DATES: [INSERT DATE OF PUBLICATION IN THE FEDERAL REGISTER].
ADDRESSES: Please refer to Docket ID NRC-2012-0258 when contacting the NRC about the availability of information regarding this document. You may obtain publicly-available information related to this document using any of the following methods:
- Federal Rulemaking Web site: Go to http://www.regulations.gov and search for Docket ID NRC-2012-0258. Address questions about NRC dockets to Carol Gallagher; telephone: 301-415-3463; e-mail: Carol.Gallagher@nrc.gov. For technical questions, contact the individual listed in the FOR FURTHER INFORMATION CONTACT section of this document.
- NRCs Agencywide Documents Access and Management System (ADAMS):
You may access publicly available documents online in the NRC Library at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ADAMS Public Documents and then select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by e-mail to PDR.Resource@nrc.gov. The ADAMS accession number for each document (if that document is available in ADAMS) is provided the first time that a document is referenced.
- NRCs PDR: You may examine and purchase copies of public documents at the NRCs PDR, Room O1-F21, One White Flint North, 11555 Rockville Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT: V. Sreenivas, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; telephone:
301-415-2597; e-mail: V.Sreenivas@nrc.gov.
SUPPLEMENTARY INFORMATION:
Notice is hereby given that the Director of the Office of Nuclear Reactor Regulation has issued a Directors Decision with regard to a petition dated October 20, 2011 (ADAMS Accession No. ML11293A116), filed by the petitioners. The petition was supplemented on November 2, 2011 (ADAMS Accession No. ML11308A027) and December 15, 2011 (ADAMS Accession No. ML12060A197). The petition concerns the operation of the North Anna Power Station, Units 1 and 2 (North Anna 1 and 2), by the Virginia Electric and Power Company (VEPCO or the licensee). The petition requested that the NRC suspend the operating licenses for North Anna 1 and 2, until the completion of a set of activities described in the
petition. The petitioner also requested that a public meeting be held to discuss this matter in the Washington, DC area.
As the basis for the October 20, 2011, request, the petitioner raised several concerns, of which 12 were accepted for review by the NRC staff by letter dated March 16, 2012 (ADAMS Accession No. ML12060A090). These summarized as follows:
(1) Prior to the approval of restart for North Anna 1 and 2, after the earthquake of August 23, 2011, Virginia Electric and Power Company (the licensee) should be required to obtain a license amendment from the NRC that reanalyzes and reevaluates the plants design basis for earthquakes and for associated necessary retrofits.
(2) Prior to the approval of restart for North Anna 1 and 2, after the earthquake of August 23, 2011, the licensee should be required to ensure that North Anna 1 and 2, are subjected to thorough inspections of the same level and rigor.
(3) The licensee should be required to reanalyze and reevaluate the North Anna Independent Spent Fuel Storage Installation (lSFSI) due to damage caused by the earthquake of August 23, 2011, and ensure that no threat is posed to public health and safety by its operation.
(4) The licensee should ensure the reliability and accuracy of the seismic instrumentation at North Anna 1 and 2.
(5) The NRC staff made hasty decisions about the restart of North Anna 1 and 2, and gave priority to economic considerations. The long-term action plan was not even complete before the NRC staff gave authorization to restart.
(6) Regulatory commitments are an inadequate regulatory tool for ensuring that the critical long-term tasks identified in the NRC staff's confirmatory action letter dated November 11, 2011, are completed.
(7) The licensee needs to address the possibility of both boildown and rapid draindown events at the North Anna 1 and 2, spent fuel pool.
(8) The long-term storage of spent fuel in the spent fuel pool at North Anna 1 and 2, and at the North Anna ISFSI poses challenges to the public health and safety.
(9) Hardened on-site storage strategies for spent fuel should be used at North Anna 1 and 2.
(10) Concerns exist about the response of North Anna 1 and 2, to a prolonged station blackout.
(11) The current emergency evacuation plans for North Anna 1 and 2, need to be revised to reflect the possible need to evacuate a larger area than that identified in the current emergency planning zone.
(12) Concerns exist about damage to the structural integrity of the spent fuel pool structure at North Anna 1 and 2, as represented on pages 41 and 42 of the NRC staff's technical evaluation for the restart of North Anna 1 and 2, dated November 11, 2011.
On December 12, 2012 and February 2, 2012, the petitioners and the licensee met with the NRC staffs petition review board (meeting transcripts under ADAMS Accession Nos.
ML12033A025 and ML12047A240), regarding the petition. These meetings gave the petitioner and the licensee an opportunity to provide additional information and to clarify issues raised in the petition.
The NRC staff issued a partial DD on October 19, 2012 (ADAMS Accession No. ML12262A156). Twelve of the concerns were accepted for review by the NRC staff. As detailed in the partial DD, eight of these concerns were closed. The remaining four concerns accepted for review were identified as those that may take longer than the target timeframe
for reaching a decision on a petition based on the fact they were undergoing NRC review as part of the agencys response to the Fukushima event in Japan.
Regarding the four remaining concerns, the NRC staff sent a copy of the proposed DD to the Petitioners and to the licensee for comment on April 17, 2015 (ADAMS Accession Nos. ML14311A616 and ML15061A133, respectively). The Petitioners provided comments in a response dated May 18, 2015 (ADAMS Accession No. ML15138A277) and the licensee provided comments in a response dated May 20, 2015 (ADAMS Accession No. ML15147A517). The comments and the NRC staff's response to them are included with this directors decision.
The Director of the Office of Nuclear Reactor Regulation has determined that the request to suspend the operating licenses for North Anna 1 and 2, until the completion of a set of activities described in the petition, be partially granted and partially denied. The reasons for this decision are explained in the director's decision DD-15-09 pursuant to Section 2.206 of Title 10 of the Code of Federal Regulations (10 CFR) of the Commissions regulations.
The NRC will file a copy of the directors decision with the Secretary of the Commission for the Commissions review in accordance with 10 CFR 2.206. As provided for by this regulation, the director's decision will constitute the final action of the Commission 25 days after the date of the decision, unless the Commission, on its own motion, institutes a review of the director's decision in that time.
Dated at Rockville, Maryland, this 21st day of August, 2015.
For the Nuclear Regulatory Commission.
/RA/
Michele G. Evans, Acting Director Office of Nuclear Reactor Regulation