ES-201 Examination Preparation Checklist Form ES-201-1 Facility: /tf, L/.s7'4'1r::- Vh1 -; Date of Examination: ?/Jo/~

Developed by: Written - Facility ::::J NRC~/ Operating - Facility LJ NRC~

Target Chief Date*

Task Description (Reference)

Examiner's Initials

-180

1.

Examination administration date confirmed (C.1.a; C.2.a and b)

A-

-120

2.

NRC examiners and facility contact assigned (C.1.d; C.2.e)

~

-120

3.

Facility contact briefed on security and other requirements (C.2.c)

~

-120

4.

Corporate notification letter sent (C.2.d)

~

[-90]

[5.

Reference material due (C.1.e; C.3.c; Attachment 3)]

~

{-75}

6.

Integrated examination outline(s) due, including Forms ES-201-2, ES-201-3, ES-301-1, ES-301-2, ES-301-5, ES-D-1's, ES-401-1/2, ES-401-3, and

~

ES-401-4, as applicable (C.1.e and f; C.3.d)

~e IL

{-70}

{7.

Examination outline(s) reviewed by NRC and feedback provided to

~

..JlseAsee-(C.2.h; C.3.e)}

{-45}

8.

Proposed examinations (including written, walk-through JPMs, and scenarios, as applicable), supporting documentation (including Forms ES-301-3, ES-301-4, ES-301-5, ES-301-6, and ES-401-6, and any Form

~

ES-201-3 updates), and reference materials due (C.1.e, f, g and h; C.3.d)

-30

9.

Preliminary license applications (NRC Form 398's) due (C.1.1; C.2.g;

~

ES-202)

-14

10. Final license applications due and Form ES-201-4 prepared (C.1.1; C.2.i;

~

ES-202)

-14

11. Examination approved by NRC supervisor for facility licensee review

/b (C.2.h; C.3.f)

-14

12. Examinations reviewed with facility licensee (C.1.j; C.2.f and h; C.3.g)

/fr

-7

13. Written examinations and operating tests approved by NRC supervisor

~

(C.2.i; C.3.h)

-7

14. Final applications reviewed; 1 or 2 (if >10) applications audited to confirm qualifications I eligibility; and examination approval and waiver letters sent

~

(C.2.i; Attachment 5; ES-202, C.2.e; ES-204)

-7

15. Proctoring/written exam administration guidelines reviewed

~

with facility licensee (C.3.k)

-7

16. Approved scenarios, job performance measures, and questions distributed to NRC examiners (C.3.i)

~

  • Target dates are generally based on facility-prepared examinations and are keyed to the examination date identified in the corporate notification letter. They are for planning purposes and may be adjusted on a case-by-case basis in coordination with the facility licensee.

[Applies only] {Does not apply} to examinations prepared by the NRC.

ES-201, Page 25 of 28

ES-201 Examination Outline Quality Checklist Form ES-201-2 Facility: /}(, ~

"it>>, e au-r 2 Date of Examination: '9 h~ /-¥ Item Task Description

1.
a. Verify that the outline(s) fit(s) the appropriate model, in accordance with ES-401.

w R

b. Assess whether the outline was systematically and randomly prepared in accordance with I

Section D.1 of ES-401 and whether all KIA cateqories are appropriately sampled.

T T

c. Assess whether the outline over-emphasizes any systems, evolutions, or generic topics.

E

d. Assess whether the justifications for deselected or rejected KIA statements are appropriate.

N

2.
a. Using Form ES-301-5, verify that the proposed scenario sets cover the required number of normal evolutions, instrument and component failures, technical specifications, s

and major transients.

I M

b. Assess whether there are enough scenario sets (and spares) to test the projected number u

and mix of applicants in accordance with the expected crew composition and rotation schedule L

without compromising exam integrity, and ensure that each applicant can be tested using A

at least one new or significantly modified scenario, that no scenarios are duplicated T

from the applicants' audit test(s). and that scenarios will not be repeated on subsequent days.

0

c.

To the extent possible, assess whether the outline(s) conform(s) with the qualitative R

and quantitative criteria specified on Form ES-301-4 and described in Appendix D.

3.
a. Verify that the systems walk-through outline meets the criteria specified on Form ES-301-2:

(1) the outline(s) contain(s) the required number of control room and in-plant tasks W

distributed among the safety functions as specified on the form I

(2) task repetition from the last two NRG examinations is within the limits specified on the form T

(3) no tasks are duplicated from the applicants' audit test(s)

4.

G E

N E

R A

L (4) the number of new or modified tasks meets or exceeds the minimums specified on the form (5) the number of alternate path, low-power, emergency, and RCA tasks meet the criteria on the form.

b. Verify that the administrative outline meets the criteria specified on Form ES-301-1:

(1) the tasks are distributed among the topics as specified on the form

c.
a.
b.
c.
d.
e.
f.

(2) at least one task is new or significantly modified (3) no more than one task is repeated from the last two NRG licensinQ examinations Determine if there are enough different outlines to test the projected number and mix of applicants and ensure that no items are duplicated on subsequent days.

Assess whether plant-specific priorities (including PRA and IPE insights) are covered in the appropriate exam sections.

Assess whether the 10 CFR 55.41/43 and 55.45 sampling is appropriate.

Ensure that KIA importance ratings (except for plant-specific priorities) are at least 2.5.

Check for duplication and overlap among exam sections.

Check the entire exam for balance of coverage.

Assess whether the exam fits the appropriate job level (RO or SRO).

a. Author LL

-.\\

/R int~d ~uielSignature

  • 1 - TTtJ I &-4--'lf :JY,k/./J
b. Facility Reviewer(*)
c. NRG Chief Examiner (#)
d. NRG Supervisor a

01

()}.

~

of\\

&'fJ

@4

()}A cM

~

@\\

~

t11l1

~

Q)J

~

(Ji!i.

Note:

  1. Independent NRG reviewer initial items in Column "c"; chief examiner concurrence required.
  • Not applicable for NRG-prepared examination outlines ES-201, Page 26 of 28 Initials b*

c#

I

~

~

~

/S 6

I~

i ~

~

~

I~

/"iP

~

~

~

7 I~

z!J'Y1ti

~

ES-201 Examination Security Agreement Form ES-201-3

1.

Pre-Examination I acknowledge that I have acquired specialized knowledge about the NRC licensing examinations scheduled for the week(s) of 9 /Z'i /! '/

as of the date of my signature. I agree that I will not knowingly divulge any information about these examinations to any persons who have not been authorized by the NRC chief examiner. I understand that I am not to instruct, evaluate, or provide performance feedback to those applicants scheduled to be administered these licensing examinations from this date until completion of examination administration, except as specifically noted below and authorized by the NRC (e.g., acting as a simulator booth operator or communicator is acceptable ifthe individual does not select the training content or provide direct or indirect feedback). Furthermore, I am aware of the physical security measures and requirements (as documented in the facility licensee's procedures) and understand that violation of the conditions of this agreement may result in cancellation of the examinations and/or an enforcement action against me or the facility licensee. I will immediately report to facility management or the NRC chief examiner any indications or suggestions that examination security may have been compromised.

2.

Post-Examination To the best of my knowledZe, I did not divulge to any unauthorized persons any information concerning the NRC licensing examinations administered during the week(s) of 'l/t11 /ti

. From the date that I entered into this security agreement until the completion of examination administration, I did not instruct, evaluate, or provide performance feedback to those applicants who were administered these licensing examinations, except as specifically notea below and authorized by the NRC.

PRINTED NAME JOB TITLE I RESPONSIBILITY SIGNATURE (1)

DATE DATE NOTE

1. 'k';c.ln..d 1 /lsluy l1/4/J4.
2. M,cJ,ael C-ule

~--

3./'f,~acl "1Aw&fe..J:,j

~/~

4~A,.) w. J.\\ a;-qcr.,"'

f.§LJS 5.jfoCb'J!l?i Hua*j

-2Lsfil:....

6. :?OHM.

K£ 1-1S-1$'"

7 ~i ~- ~

Jl)d-

~. :1ti:n~c ~

~)

IJ:Z.

1~~

1 O.&b<l"t L Cll!fltllna, f,., ~

p,. ~i' hdr;t<fq",/fu,., ie.1.

Y Ii/ __

11. C..1-fltJSfr..Jft '~Prfr'moNh MM1N fr::L_

~~::17.7~~~

~ Q2

  • ~J'$;5" 14.AD~M ~i..;...A-""1A'2-if C. o.

1-3!-1'5'

15. ~' j,t:n e... :c

].o v '-

it-t*fl(.

NOTES:S't. '"'.J" f1, "'~JU<.

1J, l Z.

~o I - ZS -t)

ES-201, Page 27 of 28

ES-201 Examination Security Agreement Form ES-201-3

1.

Pre-Examination I acknowledge that I have acquired specialized knowledge about the NRC licensing examinations scheduled for the week(s) of lfaf /;.t(;.11'1 as of the date of my signature. I agree that I will not knowingly divulge any information about these examinations to any persons who have not been authorized by the NRC chief examiner. I understand that I am not to instruct, evaluate, or provide performance feedback to those applicants scheduled to be administered these licensing examinations from this date until completion of examination administration, except as specifically noted below and authorized by the NRC (e.g., acting as a simulator booth operator or communicator is acceptable if the individual does not select the training content or provide direct or indirect feedback). Furthermore, I am aware of the physical security measures and requirements (as documented in the facility licensee's procedures) and understand that violation of the conditions of this agreement may result in cancellation of the examinations and/or an enforcement action against me or the facility licensee. I will immediately report to facility management or the NRC chief examiner any indications or suggestions that examination security may have been compromised.

2.

Post-Examination To the best of my knowledge, I did not divulge to any unauthorized persons any information concerning the NRC licensing examinations administered during the week(s) of.t91?/J111'1. From the date that I entered into this security agreement until the completion of examination administration, I did not instruct, evaluate, or provide performance feedback to those applicants who were administered these licensing examinations, except as specifically noted below and authorized by the NRC.

SIGNATURE (2)

DATE NOTE 121s Trzsfi.r..-c.1z,A.

~z~._,~~~~ £li"*'"'

\\k.<b S~qclg o es 'h<i3-rvs....i..,,...

=c

JtC~..ze

--3.L!l.Lt.::L..

.A-

~~*~-

~~

,, /IL"~ "' >'* '.:t__

JOB TITLE I RESPONSIBILITY SIGNATURE (1)

DATE

~s ~--~~.

~O-~~

~ ~ Pl'k-AJ;tM~w foe

"'f11. \\~~~t... f. Oi.... \\....

I )Q. ~M

~"

I

~12 ~

g

~

\\12-0 I

i-13

...,...,,\\ Ju:~fr-Z mX 'fM'j'.;;Jik,,z 11 11

14. =:,..._._

~tit~ 11%"[/l.,<Tlll'-

.. /;~'i

15.

-""~ DAS""""-

.i NOTES:_

"- 0

"~" E

'I ~

"'\\\\"~ \\IS<>.

~;;_____

ES-201, Page 27 of 28

ES-201 Examination Security Agreement Form ES-201-3

1.

Pre-Examination I acknowledge that I have acquired specialized knowledge about the NRG licensing examinations scheduled for the week(s) of !Jc1!Jif,4-PJ as of the date of my signature. I agree that I will not knowingly divulge any information about these examinations to any persons who have not been' authorized by the NRG chief examiner. I understand that I am not to instruct, evaluate, or provide performance feedback to those applicants scheduled to be administered these licensing examinations from this date until completion of examination administration, except as specifically noted below and authorized by the NRG (e.g., acting as a simulator booth operator or communicator is acceptable if the individual does not select the training content or provide direct or indirect feedback). Furthermore, I am aware of the physical security measures and requirements (as documented in the facility licensee's procedures) and understand that violation of the conditions of this agreement may result in cancellation of the examinations and/or an enforcement action against me or the facility licensee. I will immediately report to facility management or the NRG chief examiner any indications or suggestions that examination security may have been compromised.

2.

Post-Examination To the best of my knowledge I did not divulge to any unauthorized persons any information concerning the NRG licensing examinations administered during the week(s) ofiiiiJii'/irJ{l/-From the date that I entered into this security agreement until the completion of examination administration, I did not instruct, evaluate, or p~ormance feedback to those applicants who were administered these licensing examinations, except as specifically noted below and authorized by the NRG.

PRINTED NAME JOB TITLE I RESPONSIBILITY

1.

~fVt.1

~fl.:,""*--.---,

2.

~-

~==

3.

ScG.1-../.t:n:::,.YRE1i1<::ov:C.

p.'}(,i_;

4.

'~"""""'16'-

oP7'A~d(l 11-j";

5.

Tr.-.<-'"") Y'l1~.1V 1 1 ~

6.

,,./,' -1.-,*

ccN'2 VNll Svre'l*o.o*?/

~--

7. ? ic:. J:::>di"i.-+

R. e I sr;;,A-1z !.f___

8.

~h

... vLl:_

s-vr ;.. ~.Jl ~

1z. -;z.:!J__

9.

Af..tU ?o 4=Z...

artAJs.z7a;HJ£..

~--

10.
11.
12.
13.
14.
15.

NOTES:

ES-201, Page 27 of 28

The following individuals were placed on Exam Security Agreement:

John Riley Marc Pucel Doug Fm 1k ~

1Cj..

Kevin Dingle Dave Jacobs Normally all individuals placed on the agreement stay on it until the written exam is administered. However, because of the significant delay between the operating exam and the written exam (at least 3 weeks) it is desired to continue to have the IL T instructors work with the students.

None of the instructors listed above have any specific knowledge of the written exam.

Anyone who has or potentially has any knowledge of the written exam is staying on the agreement.

This was discussed with the NRC lead evaluator during the operating exam and he concurred.

ES-301 Operating Test Quality Checklist Form ES-301-3 Facilitv:~/£k,. ~'r.2 Date of Examination:~tf/4' Ooeratinc Test Number: /

Initials

1. General Criteria a

b*

c#

a.

The operating test conforms with the previously approved outline; changes are consistent with GI\\

4 sampling requirements (e.g., 10 CFR 55.45, operational importance, safety function distribution).

h

b.

There is no day-to-day repetition between this and other operating tests to be administered m ~

durinq this examination.

c.

The operatina test shall not duplicate items from the applicants' audit test(s). (see Section D.1.a.)

cf.J fr

d.

Overlap with the written examination and between different parts of the operating test is within efj

~

acceotable limits.

e.

It appears that the operating test will differentiate between competent and less-than-competent

&[J p.,c.

aoolicants at the desianated license level.

2. Walk-Through Criteria
a.

Each JPM includes the following, as applicable:

~

initial conditions initiating cues references and tools, including associated procedures reasonable and validated time limits (average time allowed for completion) and specific designation if deemed to be time-critical by the facility licensee ih operationally important specific performance criteria that include:

detailed expected actions with exact criteria and nomenclature system response and other examiner cues statements describing important observations to be made by the applicant criteria for successful completion of the task identification of critical steps and their associated performance standards restrictions on the sequence of steos, if aoolicable

b.

Ensure that any changes from the previously approved systems and administrative walk-through GA outlines (Forms ES-301-1 and 2) have not caused the test to deviate from any of the acceptance 4

criteria (e.g., item distribution, bank use, repetition from the last 2 NRC examinations) specified

~~

on those forms and Form ES-201-2.

3. Simulator Criteria The associated simulator operating tests (scenario sets) have been reviewed in accordance with 6fJ "IA-,A, Form ES-301-4 and a coov is attached.

Printed Name I Signature Date

a.

Author L,./f&J;64Yl)/:J~

'J )o/;<{

b.

Facility Reviewer(*)

/ft A--

,.v/,,,_

c.

NRC Chief Examiner (#)

/./ks£" /4-/~ft

~

PH7j/<./

>/

, I J.J. Z,,

r;,,.., ( \\

J

'f./!Zllj

d.

NRC Supervisor DD....._~tl~ _v d

\\..

J

/

NOTE:

The facility signature is not applicable for NRG-developed tests.

Independent NRC reviewer initial items in Column "c"; chief examiner concurrence reauired.

ES-301, Page 24 of 27

ES-301 Simulator Scenario Quality Checklist Form ES-301-4 II F;icility:jl{,/frhn~ tiu"f Z Date of Exa~.Z.-../~cenario Numbers: 3 14 ~perating Test No.:

I QUALITATIVE ATTRIBUTES Initials a

b*

c#

1.

The initial conditions are realistic, in that some equipment and/or instrumentation may be out

<1\\

  • ~ ~

of service, but it does not cue the operators into expected events.

2.

The scenarios consist mostly of related events.

0'A

~

3.

Each event description consists of the point in the scenario when it is to be initiated the malfunction(s) that are entered to initiate the event 6i1

/P the symptoms/cues that will be visible to the crew the expected operator actions (by shift position) the event termination point (if applicable)

4.

No more than one non-mechanistic failure (e.g., pipe break) is incorporated into the scenario

~

,eb without a credible precedinq incident such as a seismic event.

5.

The events are valid with reqard to physics and thermodvnamics.

~

6.

Sequencing and timing of events is reasonable, and allows the examination team to obtain

~ /h complete evaluation results commensurate with the scenario obiectives.

..l

7.

If time compression techniques are used, the scenario summary clearly so indicates.

~ ~ ~

Operators have sufficient time to carry out expected activities without undue time constraints.

Cues are qiven.

8.

The simulator modelina is not altered.

~

~

!::?

9.

The scenarios have been validated. Pursuant to 10 CFR 55.46(d), any open simulator qQ

~

performance deficiencies or deviations from the referenced plant have been evaluated to ensure that functional fidelitv is maintained while runnina the planned scenarios.

10.

Every operator will be evaluated using at least one new or significantly modified scenario.

1'J lfa All other scenarios have been altered in accordance with Section D.5 of ES-301.

11.

All individual operator competencies can be evaluated, as verified using Form ES-301-6

~

~

(submit the form alonq with the simulator scenarios).

12.

Each applicant will be significantly involved in the minimum number of transients and events

~

~

specified on Form ES-301-5 (submit the form with the simulator scenarios).

13.

The level of difficulty is appropriate to support licensinq decisions for each crew position.

~

~

Taraet Quantitative Attributes !Per Scenario; See Section D.5.dl Actual Attributes

1.

Total malfunctions (5-8)

~ IS' I

2.

Malfunctions after EOP entrv (1-2)

I I 2... I

3.

Abnormal events (2-4) 3 13 I

4.

Maior transients (1-2)

I I I I

5.

EOPs entered/requiring substantive actions (1-2\\

I I I I

6.

EOP continqencies requirinq substantive actions (0-2)

/)

I I I z 161

\\I

7.

Critical tasks (2-3)

ES-301, Page 25 of 27

ES-301 Transient and Event Checklist Form ES-301-5 Facilitv:

(./',.//.. ~

'M,,OP VA/' Z Date of Exam: 9'/.£8/#

Ooeratina Test No.:

/

A E

Scenarios p

v p

E 1

2 3

4 T

M L

N 0

I I

T CREW CREW CREW CREW T

N A

I c

POSITION POSITION POSITION POSITION L

M A

T s

A B

s A

B s

A B

s A

B u

N y

R T

0 R

T 0

R T

0 R

T 0

M(*)

T p

0 c

p 0

c p

0 c

p 0

c p

R I u E

RO RX

~

I \\

J s

\\

I S" I 2 1

1 0

D NOR

\\

I

\\ I I

\\

/

I 1

1 1

rtf0-1 I

~z..

l/C

\\

I/

y z, 7, II x,_.,

lo 4

4 2

1*'t SRO-U MAJ

\\

)

/\\

ltJ

\\

(,

I \\

z.

2 2

1 LJ TS

\\

I I \\ N'j+ ;/ \\

I/

\\

0 2

2 1,4 z

13,9 1,2,~

RX

\\

I

\\

I.; \\

I 5" \\

~ 1 1

0 SRO-I NOR

\\

J

\\ I I

\\ I

\\ I I 1

1 1

l_J l/C I\\

I I

I, 7" y 1, !J,'I v 7 4

4 2

SRO-U MAJ

\\ I

/

\\

~ /\\

t,, /\\

2 2

1 n

z.

TS

\\ I/

v

\\ N/A-- I \\ N/lf' I/ \\.v,t,. 0 2

2 RO RX I I\\

..Jt/'fl.s-I"\\

J \\

I.

I 1

1 0

D NOR I

\\

I

\\

/

\\

I I

2 1

1 1

SRO-I 0

l/C I/

\\

Z*'I

'/

z~~

// 4 4

2 I.,_..

~-U MAJ I

r-..

I \\

I \\

(,.

2.

2 2

1 1,z..

TS I

\\

/, 2.. v

\\ v

\\

1>1/,.. 2 0

2 2

RO RX I/

\\

s-5" J

1 1

0 D

NOR

~

I 1

1 1

SRO-I I

__J l/C I

\\

l.""'/

I*'/

It...

4 4

2

?Jf SRO-U MAJ I

\\

4 2

2 2

1 CZl.3

(,

TS I/

\\

1,2-3,1.f 1

0 2

2 Instructions:

1.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the "at-the-controls (ATC)"

and "balance-of-plant (BOP)" positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (l/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one l/C malfunction can be credited toward the two l/C malfunctions required for the ATC position.

2.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per Section C.2.a of Appendix D. (*)Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3.

Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicant's competence count toward the minimum reauirements soecified for the annlicant's license level in the riaht-hand columns.

ES-301, Page 26 of 27

ES-301 Competencies Checklist Form ES-301-6 Facility://(, //ske..,,

i/h_;-r z:_

Date of Examination: ~

'.ZtJ/,Y Operating Test No.: /

APPLICANTS RO 11 2)~

RO n

RO

~

RO D

SRO-I n 1,L. SRO-I

[?!'

SRO-I D

SRO-I n SRO-U D SRO-U D

  • ,:i...SRO-U !i7I

& SRO-U [!f Competencies SCENARIO SCENARIO SCENARIO SCENARIO Bor ~TC

~re. 1/0) l/.S ~

1 2

3 4

1 2

3 4

1 2

3 1

2 Interpret/Diagnose l,?t/ 1,2,~

,,,, V-'f t-6 L,6/

", '-1 1,1 7,f;?

,-1 Events and Conditions Comply With and 1,1,i *,2,3 2,,,,

1,t/

(,

-1,-r, 7,K,_,

1-i S-'

Use Procedures ( 1) l/i,., ":z.,3 2,~,

N),

Z,'(

Operate Control i S"J, 7,f "/,i Boards (2)

Communicate t'~

1,2,3 z, t,,

I,'(

'1,$)f-7, g I-'!

and Interact Demonstrate 4 4 Supervisory Ability (3)

HJ, !-'!

!-~ Afo Comply With and 1 ~

Use Tech. Specs. (3)

~ If 9 1, z. ~

Notes:

(1)

Includes Technical Specification compliance for an RO.

(2)

Optional for an SRO-U.

(3)

Only applicable to SROs.

Instructions:

Check the applicants' license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.

ES-301, Page 27 of 27 vs us 3

4

(-~

1-f ~

~.

1-f 1-'I N/,<. 1" 1-1 'I

/-f

(-1 1,z "'"

ES-401 Written Examination Quality Checklist Form ES-401-6 Facility: ;lf,)/sfrJ,,.,c. tfni f 2-Date of Exam:

Exam Level: RO i!"f sRO r!"f Initial Item Description a

b*

c*

1.

Questions and answers are technically accurate and applicable to the facility.

Cf(

j

,h

2.
a.

NRC K/As are referenced for all questions.

~

~

b.

Facilitv learnina obiectives are referenced as available.

3.

SRO questions are appropriate in accordance with Section D.2.d of ES-401 AA

~

4.

The sampling process was random and systematic (If more than 4 RO or 2 SRO questions rtA

~

were repeated from the last 2 NRC licensina exams, consult the NRR OL proaram office).

5.

Question duplication from the license screening/audit exam was controlled as indicated below (check the item that applies) and appears appropriate:

_the audit exam was systematically and randomly developed; or

!N

_the audit exam was completed before the license exam was started; or

~

./the examinations were developed independently; or

_the licensee certifies that there is no duplication; or

_other (explain)

.......... ~

6.

Bank use meets limits (no more than 75 percent Bank Modified New

~"

from the bank, at least 10 percent new, and the rest km new or modified); enter the actual RO I SRO-only 3::1 lo "

13 11 112 question distribution(s) at rioht.

7.

Between 50 and 60 percent of the questions on the RO Memory CIA exam are written at the comprehension/ analysis level; aA the SRO exam may exceed 60 percent if the randomly

~

I 2¥~ ~,7" 9o selected K/As support the higher cognitive levels; enter

/,7' the actual RO I SRO question distribution(s) at riQht.

3q 4'

~{ 19

8.

References/handouts provided do not give away answers

~

~

or aid in the elimination of distractors.

9.

Question content conforms with specific K/A statements in the previously approved krA examination outline and is appropriate for the tier to which they are assigned;

~

deviations are justified.

10.

Question Psvchometric auality and format meet the auidelines in ES Appendix B.

~

11.

The exam contains the required number of one-point, multiple choice items;

~ ' I' /?

the total is correct and acirees with the value on the cover sheet.

Printed Name I Signature Date T-J-1 -~ ~

1 "";>

.,/'}

~y

a. Author c

/(;

/.),"--/-

~

b. Facility Reviewer(*)

Al'/.4

/

t,,:;:/

~

c. NRC Chief Examiner(#)

/:-/":* --L.u /~_,.

.r;...~,,.,,.!:\\--

I

/.

"/-

d. NRC Regional Supervisor fh.u....,. -r... 61

/

114*1,J~.

JJ2/.3ti/L'-1

\\.../

Note:

  • The facility reviewer's initials/signature are not applicable for NRC-developed examinations.
  1. Independent NRC reviewer initial items in Column "c"; chief examiner concurrence required.

ES-401, Page 29 of 33

ES-403 Written Examination Grading Quality Checklist Form ES-403-1 161'/ Exam Level: R

1.
2.
3.
4.
5.
6.

Item Descri tion Applicants' scores checked for addition errors reviewers s ot check > 25% of examinations Grading for all borderline cases (80 +/-2% overall and 70 or 80, as a licable, +/-4% on the SRO-onl reviewed in detail All other failing examinations checked to ensure that grades are 'ustified Performance on missed questions checked for training deficiencies and wording problems; evaluate validity of uestions missed b half or more of the a licants Printed Name/Signature

a. Grader
b. Facility Reviewer(*)

NJ(( C- /?e-111~~ r

c. NRC Chief Examiner(*)
d. NRC Supervisor(*)

Initials a

b c

Date j 1/Z..S //l-/

(*)

The facility reviewer's signature is not applicable for examinations graded by the NRC; two inde endent NRC reviews are re uired.

ES-403, Page 6 of 6