OMY-15-018 ENCLOSURE 1 MAINE YANKEE INDEPENDENT SPENT FUEL STORAGE INSTALLATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2014
MAINE YANKEE INDEPENDENT SPENT FUEL STORAGE INSTALLATION License Nos. DPR-36 and SFGL-14 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2014
,"RSCS Radistron Safety & Control Sermces April 2015 Prepared by:
Radiation Safety & Control Services 91 Portsmouth Avenue Stratham, NH 03885-2468
EXECUTIVE
SUMMARY
Tables 1 and 2 summarize the quantity of radioactive gaseous and liquid effluents, respectively, for each quarter of 2014. There were no gaseous or liquid releases in 2014. Table 3 summarizes waste shipped off-site for disposal for each half year of 2014. There was no waste shipped for disposal in 2014.
Appendices A and B indicate the status of reportable items per the requirements of the Off-site Dose Calculation Manual (ODCM). There were no reportable items in 2014.
Appendix C presents any changes in the ODCM. The ODCM was revised in 2014.
MY 2014 Annual RER Report Page 2 of 15
Table I MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Gaseous Effluents-Summation of All Releases I Percent of reaulatorv limit N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 3 of 15
Table 1A MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Gaseous Effluents - Ground Level Releases - Batch Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter Krypton-85 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 33 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-i38 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total forerio N/A*
N/A*
N/A*
N/A*
N/A*
-odine-131 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodie-I Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-1 37 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 4 of 15
Table IB MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Gaseous Effluents - Ground Level Releases - Continuous Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter Krypton-85 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 38 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Undetified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 31 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 33 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for eriod Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-1 37 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 5 of 15
Table IC MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Gaseous Effluents - Elevated Releases - Batch Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter Krypton-85 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 38 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for eriod Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-131 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 33 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period Ci N/A*
N/A*
N/A*
N/A*
N/A*
/-
Strontium-89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-I137 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 6 of 15
Table 1 D MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Gaseous Effluents - Elevated Releases - Continuous Mode Nuclides Released Unit 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter Krypton-85 Ci N/A*
N/A*
N/A*
NIA*
N/A*
Krypton-85m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-87 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Krypton-88 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 35m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Xenon-1 38 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Udtified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Todine-1t31 Ci N/A*
N/A*
N/A*
N/A*
N/A*
-odine-133 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 35 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodie-i Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium 89 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-137 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lanthanum-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Plutonium-238 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Curium-243,244 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Uranium-234 Ci N/A*
N/A*
N/A*
N/Ak N/A*
Uranium-238 Ci N/A*
N/A*
N/A*
N/Ak N/A*
Thorium-232 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Radium-226 Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no gaseous effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 7 of 15
Table 2 MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Liquid Effluents - Summation of All Releases A. Fission and Activation Products Total Release (not including Ci N/A*
N/A*
N/A*
N/A*
N/A*
tritium, gases, alpha)
Average diluted concentration pCi/mI N/A*
N/A*
N/A*
N/A*
during period Percent of applicable limit N/A*
N/A*
N/A*
N/A*
B. Tritium Total Release Ci N/A*
N/A*
N/A*
N/A*
N/A*
Average diluted concentration PCi/ml N/A*
N/A*
N/A*
N/A*
during period Percent of applicable limit N/A*
N/A*
N/A*
N/A*
C. Dissolved and Entrained Gases Total Release Ci N/A*
N/A*
N/A*
N/A*
N/A*
Average diluted concentration pCi/mI N/A*
N/A*
N/A*
N/A*
during period I
H Percent of applicable limit N/A*
N/A*
N/A*
N/A*
D. Gross Alpha Radioactivity Total release Ci N/A*
N/A*
N/A*
N/A*
Average diluted concentration pCi/ml N/A*
N/A*
N/A*
N/A*
during period E. Volume of Waste Released Liters N/A*
N/A*
N/A*
N/A*
(prior to dilution)
F. Volume of Dilution Water Liters N/A*
N/A*
N/A*
N/A*
Used During Period N/A*= Not Applicable There are no liquid effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 8 of 15
Table 2A MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Liquid Effluents - Batch Mode Strontium-90 Ci N/A*
N/A*
N/AH NIA*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-1 37 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 31 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-58 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci NIA*
N/A*
N/A*
N/A*
N/A*
Iron-59 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Zinc-65 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Manganese-54 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Chromium-51 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Zirconium-Niobium-95 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Molybdenum-99 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Technetium-99m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lathanium-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cerium-141 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Iron-55 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Antimony-1 25 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period (above)
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Dissolved and Entrained Ci N/A*
N/A*
N/A*
N/A*
N/A*
Gasses Tritium Ci N/A*
N/A*
N/A*
N/A*
N/A*
Gross Alpha Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no liquid effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 9 of 15
Table 2B MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report 2014 Liquid Effluents - Continuous Mode Strontium-90 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-134 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cesium-1 37 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iodine-1 31 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-58 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cobalt-60 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Iron-59 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Zinc-65 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Manganese-54 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Chromium-51 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Zirconium-Niobium-95 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Molybdenum-99 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Technetium-99m Ci N/A*
N/A*
N/A*
N/A*
N/A*
Barium-Lathanium-140 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Cerium-141 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Others-Iron-55 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Antimony-1 25 Ci N/A*
N/A*
N/A*
N/A*
N/A*
Unidentified Ci N/A*
N/A*
N/A*
N/A*
N/A*
Total for period (above)
Ci N/A*
N/A*
N/A*
N/A*
N/A*
Dissolved and Entrained Ci N/A*
N/A*
N/A*
N/A*
N/A*
Gasses Tritium Ci N/A*
N/A*
N/A*
N/A*
N/A*
Gross Alpha Ci N/A*
N/A*
N/A*
N/A*
N/A*
N/A*= Not Applicable There are no liquid effluents associated with the Maine Yankee Independent Spent Fuel Storage Installation (ISFSI)
MY 2014 Annual RER Report Page 10 of 15
Table 3 MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report First Half 2014 Low Level Waste Shipments A
0 101 0
B 0
0 0
C 0
0 0
All 0
0 0
Major radionuclides for above data:
Waste Class Solidifying Agent ft3 m 3 Curies A
0 0
0 B
0 0
0 C
0 0
0 All 0
0 0
Major radionuclides for above data:
Waste Class Solidifying Agent ft3 m 3 Curies A
0 0
0 B
0 0
0 C
0 0
0 All 0
0 0
Major radionuclides for above data:
Waste Class Solidifying Agent ft3 m 3 Curies A
0 0
0 B
0 00 C
0 0
0 All 10 0
0 Major radionuclides for above data:
MY 2014 Annual RER Report Page 11 of 15
Table 3A MAINE YANKEE ISFSI Effluent and Waste Disposal Annual Report Second Half 2014 Low Level Waste Shipments M
0 101 0
B 0
0 0
C 0
0 0
All 0
0 0
Major radionuclides for above data:
Waste Class Solidifying Agent ft3 m 3 Curies A
0 0
0 B
0 0
0 C
0 0
0 All 0
0 0
Major radionuclides for above data:
Waste Class Solidifying Agent fte m 3 Curies A
0 0
0 B
0 0
0 C
0 0
0 All 0
0 0
Major radionuclides for above data:
Waste Class Solidifying Agent ft, m 3 Curies A
0 0
0 B
0 0
0 C
0 0
0 All 0
0 0
Major radionuclides for above data:
MY 2014 Annual RER Report Page 12 of 15
Appendix A Radiation Dose Assessment There were no gaseous or liquid effluent releases in 2014. Therefore, an assessment of radiation doses to the most likely exposed member(s) of the public to show compliance with 40CFR190 or 10CFR72.104 from effluents was not required.
MY 2014 Annual RER Report Page 13 of 15
Appendix B Unplanned Releases There were no unplanned releases of radioactive materials from the site in 2014.
MY 2014 Annual RER Report Page 14 of 15
Appendix C Off-site Dose Calculation Manual Changes There were changes to the Off-site Dose Calculation Manual in 2014. The primary change was to increase the TLD deployment period from quarterly to semi-annually. An analysis of TLD data over the past 5 years indicated very small dose totals at all monitoring locations and very little seasonal variation at any of the monitoring locations.
The following table describes all the changes in the ODCM.
Section Proposed Change Rationale Abstract Updated discussions to reflect that The Maine Yankee Nuclear Power Station the ODCM is addressing operations was dismantled and decommissioned in at the Maine Yankee ISFSI accordance with the Maine Yankee License Termination Plan. Subsequently, the Operating License was revised to reflect that the only areas that remain are those associated with the operation of the ISFSI.
- Abstract, Administrative, editorial, or Corrects the language and grammar utilized Table of grammatical changes.
in the document.
- Contents, 1.0, 2.0, 2.3, 3.0, and Sections 1 and 2 of Appendix A 1.0 Added references to 10 CFR 10 CFR 72.104(a) is applicable to ISFSI 72.104(a).
operations.
1.0 As applicable, expanded references The expanded references accurately reflect to 40 CFR 190 to 40 CFR 190.10(a). the correct subpart of the code.
Section 1 of Currently, the section requires any In the event that some results are not Appendix A missing data to be submitted as available for inclusion with the Annual soon as possible in a supplementary Radiological Environmental Operating report. This was revised to identify Report, the ODCM requires that the report that if the data is available, it will be note the missing data and explain the submitted in the next annual report.
reasons for the missing results.
The change relaxes the time frame for submitting any missing data. In addition, the current wording would be a compliance trap if the data was not available. These changes are administrative changes.
Table 3.1 Reduced the Frequency of Based on a review of the historical records Sampling from Quarterly to Semi-conducted by the Radiation Protection Annual.
Manager, the dose rate does not vary significantly through-out the year.
MY 2014 Annual RER Report Page 15 of 15