Notice of Deviation from Insp on 951217-960127.Deviation Noted:On 960127,inspector Identified That Procedures PT/0/A/0600/01 & MP/0/A/15009,described That Spent Fuel Pool Level Will Be Maintained Greater than -2.0 Feet from 0
ML15118A081
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 02/22/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML15118A078 List:
References
50-269-95-30, NUDOCS 9603050065
Download: ML15118A081 (1)


Text

NOTICE OF DEVIATION Duke Power Company Docket Nos. 50-269, oU-270, and 50-287 Oconee 1, 2, and 3 License Nos. DPR-38, DPR-47, and DPR-55 During an NRC inspection conducted December 17, 1995 - January 27, 1996, a deviation of your Final Safety Analysis Report was identified. In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Action", NUREG-1600, the deviation is listed below:

Final Safety Analysis Report section 9.1.4.2.3 states in part, "The fuel storage racks provide a minimum of 23.5 feet of water shielding over stored assemblies."

Contrary to the above, on January 17, 1996, the inspector identified that procedures PT/O/A/0600/01, Periodic Instrument Surveillance, and MP/0/A/1500/009, Defueling/Refueling Procedure, describe that the spent fuel pool level will be maintained greater than -2.0 feet from zero (i.e., normal operating level).

The requirement of greater than -2.0 feet from zero, translates into a minimum of 21.5 feet of water shielding over the stored assemblies.

Please provide to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, D.C. 20555, with a copy to the Regional Administrator, Region II and a copy to the NRC Resident Inspector at the facility that is subject of this Notice, in writing within 30 days of the 'date of this Notice, (1) the reason for the deviation, or if contested, the basis for disputing the deviation (2) the corrective steps that have been taken and the results achieved, (3) the corrective steps that will be taken to avoid further deviations, and (4) the date when your corrective action will be completed. Where good cause is shown, consideration will be given to extending the response time.

Dated at Atlanta, Georgia this ay of February 1996 ENCLOSURE 2 9603050065 960222 PDR ADOCK 05000269 Gj PDR