UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 April 9, 2015 Mr. Steven D. Capps Site Vice President Duke Energy Carolinas, LLC McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, NC 28078
SUBJECT:
WILLIAM B. McGUIRE NUCLEAR PLANT - NOTIFICATION OF INSPECTION AND REQUEST FOR INFORMATION
Dear Mr. Capps:
During the week of June 22 - 26, 2015, the U.S. Nuclear Regulatory Commission (NRC) will perform a baseline Radiation Safety Inspection at the McGuire Nuclear Plant (NRC Inspection Procedures 71124.06, 71124.07, and Radiation Safety Sections of 71151). In order to minimize the impact to your onsite resources and to ensure a productive inspection, we have enclosed a request for documents needed for this activity. The NRC requests that these documents be provided to the inspectors no later than June 1, 2015.
We have discussed the schedule for these inspection activities with your staff, and understand that our regulatory contact for this inspection will be Kay Crane, Senior Licensing Specialist, of your organization. If there are any questions about this inspection or the material requested, please contact the lead inspector, Wade Loo at 404-997-4727, or the Plant Support Branch 1 Chief, Brian Bonser at 404-997-4653.
This letter does not contain new or amended information collection requirements subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection requirements were approved by the Office of Management and Budget under control numbers 3150-0044, 3150-0014, 3150-0011, and 3150-0008. The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement, unless the requesting document displays a currently valid Office of Management and Budget control number.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public inspections, exemptions, requests for withholding, of the NRCs Rules of Practice, a copy of this letter, and its Enclosure, will be available electronically for public inspection in the NRC
S. Capps 2
Public Document Room, or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS); accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Sincerely,
/RA by Jonathan H. Bartley Acting for/
Brian Bonser, Chief Plant Support Branch 1 Division of Reactor Safety Docket Nos. 50-369 and 50-370 License Nos. NPF-9 and NPF-17
Enclosure:
Pre-Inspection Document Request cc: Distribution via Listserv
ML15099A647 SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DRS/PSB1 RII:DRS/PSB1 SIGNATURE WTL JHB1 for BRB1 NAME W. Loo B. Bonser DATE 4/ 9 /2015 4/ 9 /2015 E-MAIL COPY YES NO YES NO
Enclosure Pre-Inspection Document Request Inspection Dates:
June 22 - 26, 2015 Documents Due to Region II by:
June 1, 2015 Inspection Procedures (IPs):
IP 71124.06 Radioactive Gaseous and Liquid Effluent Treatment IP 71124.07 Radiological Environmental Monitoring Program IP 71151 Performance Indicator Verification Lead Inspector:
Wade Loo Senior Health Physicist U.S. NRC Region II 404-997-4727 Wade.Loo@nrc.gov Note: The current version of these documents is expected unless specified otherwise.
Electronic media is preferred if readily available. [Note that the inspectors cannot accept data provided on USB or flash drives due to the NRCs IT security policies.] Please organize the information as it is arranged below to the extent possible. Experience has shown that a poorly organized CD leads to a less efficient inspection, and places additional burden on licensee staff.
Pay particular attention to the date ranges for the items requested, as they may change from item to item. If there are questions regarding the documents requested, please do not hesitate to contact the lead inspector.
General Information Request
- 1. List of primary contacts for each inspection area below, w/phone numbers.
- 2. Plant and Radiation Protection organizational charts.
- 3. Electronic copy of applicable Chapters of Updated Final Safety Analysis Report (UFSAR)
(e.g., radiation protection program).
- 4. Corrective action program (CAP) procedures.
- 5. Most recent 10 CFR Part 61 results for the Dry Active Waste (DAW) stream.
- 6. Procedure for gathering and reporting NRC performance indicator (PI) data.
71124.06 - Radioactive Gaseous and Liquid Effluent Treatment
- 1. Site and/or corporate procedures associated with implementing the effluents and the groundwater monitoring program. Procedures should include those that address:
Effluent sampling Effluent monitor set-point determinations Dose calculations Groundwater monitoring and reporting of spills/leaks Methodology for determining effluent stack/vent flow rates
- 2. Offsite Dose Calculation Manual (ODCM) and a list of changes made in the last revision.
2
- 3. Annual Radiological Effluent Releaser Reports (ARERRs) for calendar years (CYs) 2013 and 2014.
- 4. List of liquid and gaseous effluent monitors listed as out-of-service (OOS) for > 1 day since July 1, 2013, including any special reports submitted to the NRC as a result of effluent monitor operability.
- 5. List of all unmonitored spills, leaks, or unexpected liquid/gaseous discharges since July 1, 2013. If applicable, provide the Licensee Event Report (LER), event report, and/or special report.
- 6. List of non-radioactive systems that have become contaminated and any 10 CFR 50.59 evaluations performed, since July 1, 2013.
- 7. List of any changes to the effluent release points or effluent treatment systems, and associated 10 CFR 50.59 documentation since July 1, 2013.
- 8. Material condition surveillance records for effluent system components not readily accessible, including those inaccessible due to radiological conditions.
- 9. Effluent release permits for continuous gaseous, batch gaseous, continuous liquid, and/or batch liquid releases. Only provide permits for last releases within each category.
- 10. Results of inter-laboratory comparison program for the count lab since July 1, 2013.
- 11. Last two surveillance results for the engineered safety feature (ESF) ventilation systems (e.g., system flow, HEPA, charcoal filter tests).
- 12. Groundwater monitoring results since July 1, 2013.
- 13. List of changes to the written groundwater monitoring program for identifying/controlling contaminated spills/leaks since July 1, 2013.
- 14. List of onsite surface water bodies (e.g., ponds, retention basins, lakes) that contain or potentially contain radioactivity.
- 15. List of CAP problem identification programs (PIPs) generated since July 1, 2013, related to liquid and gaseous effluent treatment and monitoring, unmonitored spills, leaks, or effluent discharges, or the groundwater monitoring program.
- 16. Audit and self-assessment documents generated since July 1, 2013, related to liquid and gaseous effluent treatment and monitoring, unmonitored spills, leaks, or effluent discharges, or the groundwater monitoring program.
71124.07 - Radiological Environmental Monitoring Program
- 1. Collection schedule for Radiological Environmental monitor Program (REMP) samples during the week of inspection.
3
- 2. Site and corporate procedures associated with radiological environmental monitoring, including:
(a) Collection, preparation, and analysis of environmental samples including air, Thermoluminescent Dosimeter (TLD) stations, ground and surface water, sediment, vegetation, milk, fish, etc.
(b) Calibration and maintenance of air and water sampling equipment.
(c) Calibration and quality control (QC) activities for sample counting instruments.
(d) Sampling and monitoring program to detect leaks from contaminated, or potentially contaminated, systems, structures, or components (SSCs).
(e) Calibration, operation, maintenance, and routine surveillances of meteorological monitoring instruments (wind speed & direction, air temperature, etc.).
- 3. Annual Radiological Environmental Operating Reports (AREORs) for CYs 2013 and 2014.
- 4. List of SSCs that contain, or could contain, licensed material for which there is a credible mechanism for the radioactive material (RAM) to reach ground water.
- 5. Summary of leaks and/or spills since July 1, 2013, (i.e. additions to the 10 CFR 50.75(g) file).
- 6. List of changes to the REMP (sample locations, sample frequency, type of samples, etc.)
since July 1, 2013.
- 7. Calibration and maintenance records for REMP air and composite water samplers since July 1, 2013.
- 8. Inter-laboratory comparison program results since July 1, 2013, (in-house or vendor laboratory).
- 9. Last two calibration/surveillance/maintenance records for the meteorological monitoring instruments since July 1, 2013, (wind speed, wind direction, and air temperature).
- 10. Results of TLD environmental monitoring since the last inspection.
- 11. List of CAP PIPs generated since July 1, 2013, related to REMP. The data should include any reviews conducted of vendor activities and their facilities (e.g., environmental lab).
- 12. Audit and self-assessment documents generated since July 1, 2013, related to REMP. The data should include any reviews conducted of vendor activities and their facilities (e.g.,
environmental lab).
71151 - Performance Indicator Verification
- 1. Monthly/Quarterly PI reports and copies of associated CAP documents, for Occupational Exposure Control Effectiveness and Radiological Effluent Technical Specifications/Offsite Dose Calculation Manual (RETS/ODCM) Radiological Effluent Occurrences since October 1, 2014.
4
- 2. Procedure(s) for identifying, notification of, tracking, and correcting PI occurrences.
- 3. Liquid and gaseous effluent release permits since October 1, 2014, which specify the quarterly and annual curies released by isotope and associated public dose assessments.
- 4. List of all CAP documents since October 1, 2014, using keywords such as high radiation area (HRA), locked high radiation area (LHRA), very high radiation area (VHRA), unintended dose, unlocked LHRA door, etc.
- 5. List of CAP documents since October 1, 2014, using keywords such as abnormal unmonitored effluent release, etc.
- 6. List of all electronic dosimeter (ED) dose rate alarms and all ED dose alarms since October 1, 2014
- 7. Audit and self-assessment documents generated since October 1, 2014, related to PIs.
LIST OF ACRONYMS AREORs Annual Radiological Environmental Operating Reports ARERRs Annual Radiological Effluent Release Reports CAP Corrective Action Program DAW Dry Active Waste ED Electronic Dosimeter ESF Engineered Safety Feature HRA High Radiation Area LER Licensee Event Report LHRA Locked High Radiation Area ODCM Offsite Dose Calculation Manual OOS Out-of-Service PI Performance Indicator PIPs Problem Identification Processes QC Quality Control RAM Radioactive Material REMP Radiological Environmental Monitor Program RETS/ODCM Radiological Effluent Technical Specifications/Offsite Dose Calculation Manual SSC Systems, Structures, or Components TLD Thermoluminescent Dosimeter UFSAR Updated Final Safety Analysis Report VHRA Very High Radiation Area