W$LF CREEK NUCLEAR OPERATING CORPORATION Steven R. Koenig Manager Regulatory Affairs March 31, 2015 RA 15-0031 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-482:

Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Gentlemen:

Enclosed is Revision 0 of the Wolf Creek Generating Station Cycle 21 Core Operating Limits Report (COLR). This document is being submitted pursuant to Section 5.6.5 of the Wolf Creek Generating Station Technical Specifications.

This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-4041.

Sincerely, Steven R. Koeni SRK/rlt Enclosure cc:

M. L. Dapas (NRC), w/e C. F. Lyon (NRC), w/e N. F. O'Keefe (NRC), w/e Senior Resident Inspector (NRC), w/e P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET

Enclosure to RA 15-0031 WOLF CREEK GENERATING STATION CYCLE 21 CORE OPERATING LIMITS REPORT, Revision 0 (17 pages)

W'*LEFCREEK

  • NUCLEAR OPERATING Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 WOLF CREEK GENERATING STATION CYCLE 21 CORE OPERATING LIMITS REPORT Revision 0 March 2015 Prepared by:

Reviewed by:

Approved by:

0:'

3/17/15 Jeff Blair Date IýA '0-0-ýý3/18/15 Keith Colussy Date Gregoy S. K3/23/15 Gregory S. Kinn Date Page 1 of 17

Wolf Creek Generating Station PACRFACREEK Core Operating Limits Report OPERATING CORPORATION Revision 0 1.0 CORE OPERATING LIMITS REPORT The CORE OPERATING LIMITS REPORT (COLR) for Wolf Creek Generating Station Cycle 21 has been prepared in accordance with the requirements of Technical Specification 5.6.5.

The core operating limits that are included in the COLR affect the following Technical Specifications:

2.1.1 Reactor Core Safety Limits 3.1.1 Shutdown Margin (SDM) 3.1.3 Moderator Temperature Coefficient (MTC) 3.1.4 Rod Group Alignment Limits 3.1.5 Shutdown Bank Insertion Limits 3.1.6 Control Bank Insertion Limits 3.1.8 PHYSICS TESTS Exceptions - MODE 2 3.2.1 Heat Flux Hot Channel Factor (FQ(z)) (FQ Methodology) 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (k'&)

3.2.3 AXIAL FLUX DIFFERENCE (AFD) (Relaxed Axial Offset Control (RAOC) Methodology) 3.3.1 Reactor Trip System (RTS) Instrumentation 3.4.1 RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits 3.9.1 Boron Concentration The portions of the Technical Specification Bases affected by the report are listed below:

ASA B 3.4.1 RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits Page 2 of 17

W"LLF CREEK WNUCLER OPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the subsections below:

2.1 Reactor Core Safety Limits (SL 2.1.1)

In MODES 1 and 2, the combination of THERMAL POWER, Reactor Coolant System (RCS) highest loop average temperature, and pressurizer pressure shall not exceed the limits in Figure 2.1.

680 660 640 620 0

600 580 560 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Fraction of Rated Thermal Power Figure 2.1 Reactor Core Safety Limits Page 3 of 17

W0LEFCREEK WNUCLAR OPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 2.2 Moderator Temperature Coefficient (MTCQ (LCO 3.1.3, SR 3.1.3.2)

The MTC shall be less positive than the limit provided in Figure 2.2.

The MTC shall be less negative than -50 pcm/ 0F.

The 300 PPM MTC Surveillance limit is -41 pcm/°F (equilibrium, all rods withdrawn, RATED THERMAL POWER condition).

The 60 PPM MTC Surveillance limit is -46 pcm/°F (equilibrium, all rods withdrawn, RATED THERMAL POWER condition).

8

-6 z

2U II.

4U 2

2 0

0 10 20 30 40 50 60

% of RATED THERMAL POWER 70 80 90 100 Figure 2.2 Moderator Temperature Coefficient Vs.

THERMAL POWER (%)

Page 4 of 17

WIF CREEK NUCLAR PERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 2.3 Shutdown Bank Insertion Limits (LCO 3.1.5)

The shutdown banks shall be fully withdrawn (i.e., positioned within the interval of_> 222 and < 231 steps withdrawn).

2.4 Control Bank Insertion Limits (LCO 3.1.6)

The Control Bank insertion, sequence, and overlap limits are specified in Figure 2.4.

(FULLY WITHDRAWN) 220 200 180 160 S

T E 140 P

S W 120 1

T H 100 D

R A

80 W

N 60 40 20 1 4.7'o 72 2

- -(---4.-t 2

rI I

TI I

r T

I I

I I

I I I

I I

I I

F I

I I

I I

I I

S I

I I

I I

I

-I I

I I

I I

I I

I I

(

0-I r-

-T F

I-

-- I

...NIK I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I I

I F I I

I I

I 0

F I

I I

F I

F I

I I

I I

I I

I I I F

I I

F I

I F

I I

I I

I I

I I

I F

-F F

F F

N F

F F

F.

F F

F F

F F

- - -i-F F-F- -

TF I

I I

I I

II I

I I

I III I

I I

-I_

- - IL 1

1 -

L j

I i

[

I L

IL I

I I

-- -T * - - - -

F-

, I J----

T--'-

1 4

4__I

_I L _ _

_ _ L -

-+/-

kI

-I I _ _ J I

I I

I I

I I

I I

I I - -

I F

F F

F F

F F

F I

F F

F F

F F

F FF_

_F

_F_

F_

_F F.

_F_.

F.

F_

+/- _

F_

l

_ _F F

F F

F F

F F

F F

F F

F F

F F

F F

FF F_

F_

_F F

F.

_F__

F.

F_ _ _ F

_.F

_F

,-F

,_F F-F-

F--

L---

I-.

2--

L-.

,w--

~ J

-__4-

-L_

I,-_-__-_. _

4-

-I------*--I--*--

I-

-F

-I--

I-.-

-I.

I.-

I

-I-i- -

.I- -

-I-----

-It---

-I---

-I-k-i-t-

-i---I F---+--I-IFI-I I

I--

FI

-+

-I FI

-I---

I I

U 0

(FULLY INSERTED) 20 40 60 THERMAL POWER (Percent) 80 100 Figure 2.4 Control Bank Insertion, Sequence, and Overlap Limits Vs.

THERMAL POWER (%) - Four Loop Operation Fully withdrawn shall be the condition where control banks are at a position within the interval of k 222 and < 231 steps withdrawn.

Page 5 of 17

WEcLF CREEK OPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 2.5 AXIAL FLUX DIFFERENCE (AFD) (Relaxed Axial Offset Control (RAOC)

Methodoloav) (LCO 3.2.3)

The indicated AXIAL FLUX DIFFERENCE (AFD) allowed operational space is defined by Figure 2.5.

110 100

(

0 F

90 R

A T

E D 80 T

H E

R 70 M

A L

P 60 0

W E

R 50 40 UNACCEPTABLE OPERATION

-29,o0 ACCEPTABLE OPERATION UNACCEPTABLE OPERATION (24,50

-40

-30

-20

-10 0

10 20 AXIAL FLUX DIFFERENCE (%AI) 30 40 Figure 2.5 AXIAL FLUX DIFFERENCE Limits as a Function of THERMAL POWER (%)

Page 6 of 17

Wolf Creek Generating Station W LF LK K

Cycle 21 NUCL PERATNG CORPORATION Core Operating Limits Report

__________CORPORATIONRevision 0 2.6 Heat Flux Hot Channel Factor (F4(Z))(Fq Methodology) (LCO 3.2.1, SR 3.2.1.2)

FQ 2(Z) CFQ *K(Z), for P > 0.5 P

F2(Z)<CFQ *K(Z), for P <_ 0.5 0.5 where, P

-THERMAL POWER RATED THERMAL POWER CFQ = F TP p1R TP

= FQ(Z) limit at RATED THERMAL POWER (RTP)

= 2.50, and K(Z) = as defined in Figure 2.6.

F,,(Z) is the measured value of FQ(Z), inferred from a power distribution measurement obtained with the Movable Incore Detector System (MIDS) or the Power Distribution Monitoring System.

Measurement uncertainty is applied as follows.

FJ(Z)= F*(Z)(1.O3)(1.05)=FQ'(Z)(I.0815) when Fc4(Z) is obtained from MIDS.

F* (Z) = FQA(Z)(1.03)(UQu) when F* (Z) is obtained from PDMS.

Manufacturing tolerances are accounted for in the 1.03 Engineering uncertainty factor. Measurement uncertainty for MIDS is accounted for in the 1.05 factor.

PDMS measurement uncertainty is accounted for in the UQu factor, and it is determined by PDMS.

Fgw (Z)=F5 (Z) W(Z) where, W(Z) = a cycle dependent function that accounts for power distribution transients encountered during normal operation (see Appendix A).

When using the PDMS, Fw(Z) uses Fg(Z) that is determined from an F*j(Z) that reflects full-power steady-state conditions rather than current conditions.

See Appendix A for: Fo, Penalty Factor.

Page 7 of 17

WLEFCREEK NucLEAR oPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 1.2 I

I I

I I.

I I

I 0C-,

U.

zZ UJ CL aw

-J 0Z I

I I

I I

I I

I I

I I

I 1.0 0.8 0.6 0.4 0.2 I -

F RW = 2.50 i

-Elevation (ft)

K(Z) 0.0 1.0001 6.0 1.000 12.0 0.925 0.0 0

2 4

6 8

10 12 CORE HEIGHT (FT)

Figure 2.6 K(Z) - Normalized Peaking Factor Vs. Core Height Page 8 of 17

Wolf Creek Generating Station 1NUCLEAF C R E EK Core Operating Limits Report OPERATING CORPORATION Revision 0 2.7 Nuclear Enthalpy Rise Hot Channel Factor (FN)

(LCO 3.2.2)

F[N shall be limited by the following relationship:

F* < FTP [1.+Pa10 P)]

Where, FR[P = FA limit at RATED THERMAL POWER (RTP)

= 1.650 PFA

= power factor multiplier for FAN

= 0.3 P

=

THERMAL POWER RA TED THERMAL POWER FL

=

FN is the measured value of FN, inferred from a power distribution measurement obtained with the Movable Incore Detector System (MIDS) or the Power Distribution Monitoring System (PDMS). Measurement uncertainty is applied as follows.

When FaNH is obtained from MIDS, the measured value is multiplied by 1.04.

When FH is obtained from PDMS, the measured value is increased by an uncertainty factor (UAH), and the factor is determined by PDMS, with a lower limit of 4%.

Page 9 of 17

MikiCREEK OPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 2.8 Reactor Trip System Overtemperature AT Setpoint Parameter Values (LCO 3.3.1, Table 3.3.1-1, Note 1)

Parameter Overtemperature AT reactor trip setpoint Overtemperature AT reactor trip setpoint Tavg coefficient Overtemperature AT reactor trip setpoint pressure coefficient Nominal Tavg at RTP Nominal RCS operating pressure Measured RCS AT lead/lag constant Measured RCS AT lag constant Measured RCS average temperature lead/lag constant Value K1 = 1.10 K2 = 0.0137/1F K3 = 0.000671/psig T' _< 586.50F P' > 2235 psig Tl = 6 sec 12 =3 sec "U3= 2 sec T4= 16 sec

,u5 = 4 sec Measured RCS average temperature lead/lag r6 = 0 sec constant f,(AI) = -0.0227 {23% + (qt-qb)} when (qt-qb) < -23% RTP 0% of RTP when -23% RTP _ (qt-qb) -< 5% RTP 0.01 84 {(qt-qb) - 5%}

when (qt-qb) > 5% RTP Where, qt and qb are percent RTP in the upper and lower halves of the core, respectively, and qt + qb is the total THERMAL POWER in percent RTP.

Page 10 of 17

Wolf Creek Generating Station W0V tF CEK Cycle 21 NUCL PERATING CORPORATION Core Operating Limits Report

__________CORPORATIONRevision 0 2.9 Reactor Trip System Overpower AT Setpoint Parameter Values (LCO 3.3.1, Table 3.3.1-1, Note 2)

Parameter Value Overpower AT reactor trip setpoint K4 = 1.10 Overpower AT reactor trip setpoint Tavg K5 = 0.02/°F for increasing Tavg rate/lag coefficient

= 01/F for decreasing Tavg Overpower AT reactor trip setpoint Tavg heatup K6 = 0.00128/°F forT> T" coefficient

= 0/°F for T < T" Indicated Tavg at RTP (calibration temperature T" _< 586.50F for AT instrumentation)

Measured RCS AT lead/lag constant T=

=6 sec T2 = 3 sec Measured RCS AT lag constant T3= 2 sec Measured RCS average temperature lead/lag T6 = 0 sec constant Measured RCS average temperature rate/lag T7 = 10 sec constant f2(AI) = 0% RTP for all Al Page 11 of 17

Y~cECREEK OPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 2.10 RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB)

Limits (LCO 3.4.1)

Parameter Pressurizer pressure RCS average temperature RCS total flow rate Indicated Value Pressure _> 2220 psig Tavg -< 590.5 °F Flow __ 371,000 gpm 2.11 Boron Concentration (LCO 3.9.1)

The refueling boron concentration shall be greater than or equal to 2300 PPM.

2.12 SHUTDOWN MARGIN (LCO 3.1.1, 3.1.4, 3.1.5, 3.1.6, & 3.1.8)

The SHUTDOWN MARGIN shall be greater than or equal to 1300 pcm (1.3% Ak/k).

2.13 Departure from Nucleate Boiling Ratio (DNBR) Limits (B 3.4.1, ASA)

Safety Analysis DNBR Limit 1.76 WRB-2 Design Limit DNBR 1.23 Page 12 of 17

W0pELFCREEK

'NUCEAR PERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 APPENDIX A A.

Input relating to LCO 3.2.1:

¥(Z) - FQ (Z) m x transient 1

FQ(Z)seadyste p

W Fp ( Z l iatransient W (Z)

= FQ (Z)eaystate 0.5

where, P =

THERMAL POWER RATED THERMAL POWER for P > 0.5 for P < 0.5 FQ(Z)max transient = Maximum (FQ(Z) xp) calculated over the entire range of power shapes analyzed for Condition I operations (p = power at which maximum occurs).

FQ(Z)siea state = (FQ(Z) xp) calculated at full power (p = 1.0) equilibrium conditions.

The W(z) values are generated at full power equilibrium conditions (P = 1.0). W(z) values specific to part-power conditions may also be generated; these can be used for part-power surveillance measurements, rather than the full-power W(z) values.

For these part-power W(z) values, the FQ(Z)steady state (denominator in above equations) is generated at the specific anticipated surveillance conditions.

W(Z) values are issued in controlled reports which will be provided on request.

Page 13 of 17

W$F CREEK NUCLEAR OPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0 Input relating to SR 3.2.1.2 Cycle Burnup (MWD/MTU)

> 0 to < 150 348 546 743 to 8456 8654 8852 9049 9247 9445 9643 9840 10038 10236 10434

> 10631 Cycle Burnup (MWD/MTU)

FQ (Z) Penalty Factor

(%)

3.08 2.76 2.38 2.00 2.06 2.26 2.44 2.40 2.38 2.36 2.31 2.23 2.15 2.06 2.00 FQ (Z) Exclusion Zone

(% (INCORE mesh points])

Top Bottom 15011]

15[11]

10 [7]

10 [7]

< 8,000

> 8,000 Page 14 of 17

Wolf Creek Generating Station PRICOOLTFC R EEK Core Operating Limits Report OPERATING CORPORATION Revision 0 B.

Approved Analytical Methods for Determining Core Operating Limits The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents.

1. WCNOC Topical Report TR 90-0025 W01, "Core Thermal Hydraulic Analysis Methodology for the Wolf Creek Generating Station." (ET 90-0140, ET 92-0103)

NRC Safety Evaluation Report dated October 29, 1992, for the "Core Thermal Hydraulic Analysis Methodology for the Wolf Creek Generating Station."

2. WCAP-1 1397-P-A, "Revised Thermal Design Procedure," April 1989.

NRC Safety Evaluation Report dated January 17, 1989, for the "Acceptance for Referencing of Licensing Topical Report WCAP-1 1397, Revised Thermal Design Procedure."

3.

WCNOC Topical Report NSAG-006, "Transient Analysis Methodology for the Wolf Creek Generating Station" (ET-91-0026, ET 92-0142, WM 93-0010, WM 93-0028).

NRC Safety Evaluation Report dated September 30, 1993, for the "Transient Analysis Methodology for the Wolf Creek Generating Station."

EPRI Topical Report NP-7450(A), "RETRAN-3D - A Program for Transient Thermal-Hydraulic Analysis of Complex Fluid Flow Systems," including NRC Safety Evaluation Report dated January 25, 2001, "Safety Evaluation Report on EPRI Topical Report NP-7450(P), Revision 4, "RETRAN-3D - A Program for Transient Thermal-Hydraulic Analysis of Complex Fluid Flow Systems,"

(TAC No. MA431 1)." RETRAN-3D code is only utilized in the RETRAN-02 mode.

4.

WCAP-1 0216-P-A, Revision 1A, "Relaxation of Constant Axial Offset Control - FQ Surveillance Technical Specification," February 1994.

NRC Safety Evaluation Report dated November 26, 1993, "Acceptance for Referencing of Revised Version of Licensing Topical Report WCAP-10216-P, Rev. 1, Relaxation of Constant Axial Offset Control - FQ Surveillance Technical Specification" (TAC No. M88206).

5.

WCNOC Topical Report NSAG-007, "Reload Safety Evaluation Methodology for the Wolf Creek Generating Station" (ET 92-0032, ET 93-0017).

NRC Safety Evaluation Report dated March 10, 1993, for the "Reload Safety Evaluation Methodology for the Wolf Creek Generating Station."

6.

NRC Safety Evaluation Report dated March 30, 1993, for the "Revision to Technical Specification for Cycle 7" (NA 92-0073, NA 93-0013, NA 93-0054).

Page 15 of 17

Wolf Creek Generating Station PAIC PAFICR E EK Core Operating Limits Report OPERATING CORPORATION Revision 0

7.

WCAP-1 0266-P-A, Revision 2, "The 1981 Version of the Westinghouse ECCS Evaluation Model Using the BASH Code," March 1987.

NRC letter dated November 13, 1986, "Acceptance for Referencing of Licensing Topical Report WCAP-1 0266 "The 1981 Version of the Westinghouse ECCS Evaluation Model Using the BASH Code.""

WCAP-10266-P-A, Addendum 1, Revision 2, "The 1981 Version of the Westinghouse ECCS Evaluation Model Using the BASH Code Addendum 1:

Power Shape Sensitivity Studies," December 1987.

NRC letter dated September 15, 1987, "Acceptance for Referencing of Addendum 1 to WCAP-10266, BASH Power Shape Sensitivity Studies."

WCAP-10266-P-A, Addendum 2, Revision 2, "The 1981 Version of the Westinghouse ECCS Evaluation Model Using the BASH Code Addendum 2:

BASH Methodology Improvements and Reliability Enhancements," May 1988 NRC letter dated January 20, 1988, "Acceptance for Referencing Topical Report Addendum 2 to WCAP-10266, Revision 2, "BASH Methodology Improvements and Reliability Enhancements."

8.

WCAP-16045-P-A, "Qualification of the Two-Dimensional Transport Code PARAGON," August 2004.

NRC Safety Evaluation dated March 18, 2004, "Final Safety Evaluation for Westinghouse Topical Report WCAP-16045-P, Revision 0, "Qualification of the Two-Dimensional Transport Code PARAGON."

9.

WCAP-16045-P-A, Addendum 1-A, "Qualification of the NEXUS Nuclear Data Methodology," August 2007.

NRC Safety Evaluation dated February 23, 2007, "Final Safety Evaluation for Westinghouse Electric Company (Westinghouse) Topical Report (TR) WCAP-16045-P-A, Addendum 1, "Qualification of the NEXUS Nuclear Data Methodology" (TAC NO. MC9606)."

10. WCAP 10965-P-A, "ANC: A Westinghouse Advanced Nodal Computer Code,"

September 1986.

NRC letter dated June 23, 1986, "Acceptance for Referencing of Topical Report WCAP 10965-P and WCAP 10966-NP."

11. WCAP-1 2610-P-A, "VANTAGE+ Fuel Assembly Reference Core Report," April 1995.

NRC Safety Evaluation Reports dated July 1, 1991, "Acceptance for Referencing of Topical Report WCAP-12610, 'VANTAGE+ Fuel Assembly Reference Core Report' (TAC NO. 77258)."

NRC Safety Evaluation Report dated September 15, 1994, "Acceptance for Referencing of Topical Report WCAP-1 2610, Appendix B, Addendum 1,

'Extended Burnup Fuel Design Methodology and ZIRLO Fuel Performance Models' (TAC NO. M86416)."

Page 16 of 17

VWtLFCREEK NPERATING CORPORATION Wolf Creek Generating Station Cycle 21 Core Operating Limits Report Revision 0

12. WCAP-8745-P-A, "Design Bases for the Thermal Overpower AT and Thermal Overtemperature AT Trip Function." September 1986.

NRC Safety Evaluation Report dated April 17, 1986, "Acceptance for Referencing of Licensing Topical Report WCAP-8745(P)/8746(NP), 'Design Bases for the Thermal Overpower AT and Thermal Overtemperature AT Trip Functions."'

Page 17 of 17