ML15092A355
| ML15092A355 | |
| Person / Time | |
|---|---|
| Site: | SHINE Medical Technologies |
| Issue date: | 03/23/2015 |
| From: | Bynum R Shine Medical Technologies |
| To: | Office of Nuclear Reactor Regulation |
| Lynch S | |
| References | |
| SHINE, SHINE.SUBMISSION.10, SHN.PSAR.P, SHN.PSAR.P.4 | |
| Download: ML15092A355 (7) | |
Text
Chapter 7 - Instrument & Control Systems Summary Description SHINE Medical Technologies Rev. 0 Figure 7a2.1 Safety Approach for TSV Shutdown Neutron Flux Detection System TSV Reactivity Protection System (TRPS)
Operator Interface Displays Power Source Dedicated NOTrip Breaker Dedicated NOTrip Breaker A
A Target Solution Vessel (TSV)
B B
Target Solution Dump Tank A
B Target Solution Irradiated Target Solution IU Cell Boundary Neutron Driver (NDAS)
TSV Inlet Isolation Valves TSV Dump Valves Dump Tank Outlet Isolation Valves Wiring Distribution Enclosure Control Room Neutron Flux Detector x3 TSV Process Control System (TPCS)
Chapter 7 - Instrument & Control Systems Design of Instrument and Control Systems SHINE Medical Technologies Rev. 0 Figure 7a2.2 I&C System Block Diagram for Irradiation Facility Annunciator Display TSV Reactivity Protection System TRPS Engineered Safety Features Actuaton System (ESFASA)
TSV Process Control System TPCS Annunciator Display Detail DrillDown Display Event Log Annuciator Display Detail DrillDown Display Event Log Annunciator Display SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #1 IU Cell #1 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #2 IU Cell #2 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #3 IU Cell #3 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #4 IU Cell #4 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #5 IU Cell #5 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #6 IU Cell #6 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #7 IU Cell #7 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #8 IU Cell #8 Safety Related Process Control NonSafety Engineered Safety Features Actuaton System (ESFASB)
Isolated Links
Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System SHINE Medical Technologies Rev. 0 Figure 7a2.5 Typical ESF Circuit K1 K2 L1 Coil Output ESF A N
TPCS ESD PB A1 A2 C1 IN 1 SENSE 1 SENSE 2 RESET Other Relays in IU Cell Group Relay Monitor Relay Output RESET PB K1 K2 A1 A2 SENSE 1 SENSE 2 RESET Relay Monitor Relay Output IN 2 ESF A Relay 1 ESF A Relay 2 (L+)
(O REF)
Detector B OUT 2 Detector A OUT 1 Other Detectors
Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System SHINE Medical Technologies Rev. 0 Figure 7a2.5 Example ESFAS Panel 12" Above Floor 0.0 in.
3.6 in. 6.0 in.
12.0 in.
16in.
29in.
42in.
3in.
IU Cell #1 IU Cell #2 IU Cell #3 IU Cell #4 IU Cell #5 IU Cell #6 IU Cell #7 IU Cell #8 1
3 5
7 9
2 4
6 8
10 12 11 1
2 3
4 5
6 BubbleTight Inlet Damper Relays 7
8 9
10 11 BubbleTight Outlet Damper Relays PCLS Inlet Isolation Valve Relays LWPS Inlet Isolation Valve Relays LWPS Outlet Isolation Valve Relays 12 Spare PCLS Outlet Isolation Valve Relays Tritium Delivery Isolation Valve Relays Tritium Return Isolation Valve Relays TRPS Input Signal Trip Relays Spare Spare
Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System SHINE Medical Technologies Rev. 0 Figure 7a2.5 ESFAS Manual Operator Panel IU Cell #4 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK IU Cell #3 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK IU Cell #2 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK IU Cell #1 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK IU Cell #5 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK IU Cell #6 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK IU Cell #7 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK IU Cell #8 ESD A ESD B RESET A RESET B TRPPED A TRPPED B OVERRIDE A
OVERRIDE B
BULB CHECK 33" Above Ground 0.0 in.
3.6 in. 6.0 in.
12.0 in.
Tripped Illumination Override Illumination ESD Pushbutton Reset Pushbutton Check Pushbutton 19in.
27in.
39in.
7in.
4' by 5' Panel
Chapter 7 - Instrument & Control Systems Control Console and Display Information SHINE Medical Technologies Rev. 0 Figure 7a2.6 Irradiation Facility Workstation Layout Keyboard Keyboard Keyboard TRPS Fixed Status Display TPCS Fixed Status Display TRPS Alarm/ Event Display TPCS Alarm/ Event Display TRPS HMI Display TPCS HMI Display RICS Status Display RICS Alarm Display RICS HMI Display
Chapter 7 - Instrument & Control Systems Control Console and Display Information SHINE Medical Technologies Rev. 0 Figure 7a2.6 Control Room Layout Security-Related Information - Withhold under 10 CFR 2.390