CNL-15-002, Application to Modify Technical Specification 2.1.1.2, Reactor Core Minimum Critical Power Ratio Saftey Limits (TS-499)
| ML15090A436 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry (DPR-068) |
| Issue date: | 03/06/2015 |
| From: | James Shea Tennessee Valley Authority |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML15090A434 | List: |
| References | |
| CNL-15-002, T.S. 2.1.1.2 L44 150306 001 | |
| Download: ML15090A436 (36) | |
Text
Proprietary Information Withhold Under 10 CFR 2.390(d)(1)
This letter is decontrolled when separated from Attachment 3 of the Enclosure Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 CNL-15-002 March 6, 2015 ATTN : Document Control Desk U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Unit 3 Renewed Facility Operating License No. DPR-68 NRC Docket No. 50-296 10 CFR 50.90
Subject:
Browns Ferry Nuclear Plant (BFN), Unit 3 - Application to Modify Technical Specification 2.1.1.2, Reactor Core Minimum Critical Power Ratio Safety Limits (TS-499)
Reference:
- 1. Letter from NRC to TVA, "Browns Ferry Nuclear Plant, Units 1, 2, and 3-Issuance of Amendments Regarding Technical Specifications (TS) Change TS-478 Addition of Analytical Methodologies toTS 5.6.5 and Revision of TS 2.1.1.2 for Unit 2 (TAC NOS. MF0877, MF0878, and MF0879)," dated July 31, 2014 (ADAMS Accession No. ML14108A334)
In accordance with the provisions of 10 CFR 50.90, "Application for amendment of license, construction permit, or early site permit," the Tennessee Valley Authority (TVA) is submitting a request for amendment to the Technical Specifications (TS) for Browns Ferry Nuclear Plant (BFN), Unit 3. The proposed amendment modifies the TS 2.1.1.2 value of the safety limit minimum critical power ratio (SLMCPR) for two-loop operation to 1.06 and the SLMCPR for single loop operation to 1.08. The revised SLMCPR values reflect a reduction from the current values, and are supported by the application of the methodology approved for BFN, Unit 3, in Technical Specifications Change TS-478 (Reference 1).
The enclosure to this letter provides a description of the proposed changes, a technical evaluation of the proposed changes, a regulatory evaluation, and a discussion of environmental considerations. Attachment 1 of the enclosure provides the existing BFN, Unit 3, TS marked-up to show the proposed changes. Attachment 2 of the enclosure provides clean typed BFN, Unit 3 TS pages revised to show the proposed changes. There are no TS Bases changes.
Attachments 3 and 4 of the enclosure contain technical information supporting the acceptability of the revised TS 2.1.1.2 limit. Attachment 3 contains information that AREVA NP considers to be proprietary in nature and subsequently, pursuant to 10 CFR 2.390, "Public inspections, exemptions, requests for withholding," paragraph (a)(4),
L44 150306 001
U. S. Nuclear Regulatory Commission CNL-15-002 Page 2 March 6, 2015 it is requested that such information be withheld from public disclosure. Attachment 4 contains the non-proprietary version of the Attachment 3 report with the proprietary material removed, and is suitable for public disclosure. Attachment 5 of the enclosure provides the affidavit supporting this request.
TVA has determined that there are no significant hazards considerations associated with the proposed changes and that the TS changes qualify for a categorical exclusion from environmental review pursuant to the provisions of 10 CFR 51.22(c)(9). Additionally, in accordance with 10 CFR 50.91 (b)(1 ), TVA is sending a copy of this letter and the enclosure to the Alabama State Department of Public Health.
The BFN Plant Operations Review Committee and the TVA Nuclear Safety Review Board have reviewed this proposed change and determined that operation of BFN in accordance with the proposed change will not endanger the health and safety of the public.
TVA requests approval of these proposed TS changes by February 15, 2016, with implementation within 60 days of issuance.
There are no new regulatory commitments associated with this submittal. If there are any questions or if additional information is needed, please contact Mr. Edward D. Schrull at (423) 751-3850.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 6th day of March 2015.
Respectfully, 4~
gwd,e._
J. W. Shea Vice President, Nuclear Licensing
Enclosure:
- 1.
Technical Specifications Change TS-499-Change to Technical Specification 2.1.1.2 for Browns Ferry Unit 3 Attachments:
- 1.
- 2.
- 3.
- 4.
- 5.
Proposed Technical Specification Page Markups Proposed Retyped Technical Specifications Pages Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology (Proprietary)- AREVA FS1-0020053, Rev. 1 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology (non-proprietary) -AREVA FS1-0020054, Rev. 1 Affidavit for Withholding of AREVA Report FS1-0020053, Rev. 1 from Public Disclosure
U. S. Nuclear Regulatory Commission CNL-15-002 Page 3 March 6, 2015 cc (Enclosure):
NRC Regional Administrator-Region II NRC Senior Resident Inspector-Browns Ferry Nuclear Plant State Health Officer, Alabama State Department of Public Health
Enclosure Browns Ferry Nuclear Plant (BFN) Unit 3 Technical Specifications Change TS-499 Change to Technical Specification 2.1.1.2 for Browns Ferry Unit 3 1.0
SUMMARY
DESCRIPTION This evaluation supports a request to amend the Operating License for Browns Ferry Nuclear Plant (BFN), Unit 3 (DPR-68). The proposed change modifies the BFN, Unit 3 Technical Specification (TS) 2.1.1.2 value of the safety limit minimum critical power ratio (SLMCPR) for two-loop operation to 1.06 and the SLMCPR for single loop operation to 1.08.
The revised SLMCPR values reflect a reduction from the current values, supported by the application of the SAFLIM3D methodology approved for BFN, Unit 3, by the Safety Evaluation for TS-478 (Reference 1).
2.0 DETAILED DESCRIPTION To support the use of the ATRIUM-10 XM fuel design in BFN, Unit 2, commencing in the spring of 2015, the Tennessee Valley Authority (TVA) submitted TS-478 (Reference 2), a license amendment request (LAR) to revise the operating licenses of BFN, Units 1, 2, and 3 to add three additional AREVA analytical methodologies. One of these methodologies is SAFLIM3D (Reference 3). The NRC approved the addition of this methodology to TS 5.6.5.b for all three BFN units, including BFN, Unit 3 as part of the approval of TS-478 (Reference 1 ).
In the NRC approval of TS-478, the BFN, Unit 2 SLMCPR values were also conservatively reduced based on results obtained from application of the AREVA SAFLIM3D SLMCPR method. The BFN, Unit 2 SLMCPR values were reduced to 1.06 and 1.08 for two-loop and single loop operation, respectively.
This LAR (TS-499) requests approval of a similar change to the BFN, Unit 3 SLMCPR. The proposed amendment revises the SLMCPR values in TS 2.1.1.2 for two-loop operation from the current value of 1.09 to 1.06, and the single loop operation value from the current value of 1.11 to 1.08. The proposed change makes the BFN, Unit 3 SLMCPR values identical to those already approved for BFN, Unit 2. of the enclosure provides the existing BFN, Unit 3, TS marked-up to show the proposed changes. Attachment 2 of the enclosure provides clean typed BFN, Unit 3 TS pages revised to show the proposed changes.
In support of the proposed TS change, AREVA has performed a BFN, Unit 3 specific evaluation based on a representative Cycle 18 core design to demonstrate that the proposed SLMCPR values are conservative. A proprietary version of this report is included as Attachment 3; a non-proprietary version is included as Attachment 4. An affidavit for withholding the proprietary version from public disclosure is included as Attachment 5.
E-1
3.0 TECHNICAL EVALUATION
Three additional AREVA analytical methods (RODEX4, ACE, and SAFLIM3D) were added toTS 5.6.5.b as part of the NRC approval ofTS-478. Beginning with Cycle 18, BFN, Unit 3, (projected to begin in the Spring of 2016) will use the SAFLIM3D methodology for determining the SLMCPR values for two-loop and single loop operation.
The SAFLIM3D methodology described in Reference 3 was used to calculate the SLMCPR such that no more than 0.1% of fuel rods in the core experience boiling transition during normal operation and anticipated operational occurrences. The SLMCPR was determined using a statistical analysis that employs a Monte Carlo process that perturbs key input parameters used in the MCPR calculation. The SAFLIM3D methodology uses the approved critical power correlations to calculate the CPR for a fuel assembly based on the thermal hydraulic conditions and power distribution of the assembly.
Application of the SAFLIM3D methodology to BFN, Unit 3 is in conformance with the license condition specified by the NRC in the approval of TS-478 (Reference 1 ). The SE states:
"The fuel channel bow standard deviation component of the channel bow model uncertainty used by ANP-10307PA, "AREVA MCPR Safety Limit Methodology for Boiling Water Reactors, Revision 0," (i.e., TS 5.6.5.b.10) to determine the SLMCPR shall be increased by the ratio of channel fluence gradient to the nearest channel fluence gradient bound of the channel measurement database, when applied to channels with fluence gradients outside the bounds of the measurement database from which the model uncertainty is determined."
In support of the requested change, AREVA has performed a BFN, Unit 3 specific evaluation (Attachments 3 and 4) based on a representative Cycle 18 design to demonstrate that the proposed SLMCPR values are conservative. The Cycle 18 reload is the transition cycle in which the first reload of ATRIUM-10 XM fuel is introduced. The balance of the fuel in the Cycle 18 core will be ATRIUM-1 0 fuel. This mix of fuel types is the same as the BFN, Unit 2 Cycle 19 core used to support the BFN, Unit 2 SLMCPR change in TS-478.
The SLMCPR results presented in Attachment 3 support a two-loop operation SLMCPR value of 1.03 and a single loop operation SLMCPR value of 1.05. The proposed BFN, Unit 3 TS SLMCPR values of 1.06 for two-loop operation and 1.08 for single loop operation were conservatively selected relative to the values discussed in Attachment 3, to establish TS values that would not routinely require changing for future BFN, Unit 3 reloads.
No plant hardware or operational changes are required as a result of the proposed license amendments.
4.0 REGULATORY EVALUATION
4.1 APPLICABLE REGULATORY REQUIREMENTS/CRITERIA 10 CFR 50, Appendix A, General Design Criteria (GDC) 10, "Reactor Design," states that the reactor core and associated coolant, control, and protection systems shall be designed with appropriate margin to assure that specified acceptable fuel design limits are not exceeded during any condition of normal operation, including the effects of anticipated operation occurrences. The proposed change in the SLMCPR values in TS 2.1.1.2 complies with the requirements of GDC 10 and will continue to assure that fuel clad integrity E-2
is maintained.
10 CFR 50.36(c)(1) requires that safety limits (Sls) be included in the Technical Specifications. Sls for nuclear reactors are limits upon important process variables that are found to be necessary to reasonably protect the integrity of certain of the physical barriers that guard against the uncontrolled release of radioactivity. The proposed change modifies the existing SL 2.1.1.2 values.
4.2 PRECEDENT The NRC has previously approved the reduction of the BFN, Unit 2 SLMCPR values based on results obtained from the AREVA SAFLIM3D SLMCPR method. The relevant portion of the license amendment listed below provides the precedent.
- 1. Letter from NRC to TVA, "Browns Ferry Nuclear Plant, Units 1, 2, and 3-Issuance of Amendments Regarding Technical Specifications (TS) Change TS-478 Addition of Analytical Methodologies toTS 5.6.5 and Revision of TS 2.1.1.2 for Unit 2," dated July 31, 2014 (TAG NOS. MF0877, MF0878, and MF0879) (ADAMS Accession No. ML14108A334) 4.3 NO SIGNIFICANT HAZARDS CONSIDERATION This analysis addresses the proposed change to amend Operating License DPR-68 to reduce the Technical Specification (TS) 2.1.1.2 Safety Limit Minimum Critical Power Ratio (SLMCPR) values.
TVA has evaluated whether or not a significant hazards consideration is involved with the proposed amendment by focusing on the three standards set forth in 10 CFR 50.92, "Issuance of amendment," as discussed below:
- 1. Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?
Response: No The proposed TS revision is based on the implementation of a previously approved methodology. As such, it involves no changes to the operation of any system or component during normal, accident, or transient operating conditions. The change does not affect the initiators of any accident. Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
- 2. Does the proposed amendment create the possibility of a new or different kind of accident from any accident previously evaluated?
Response: No The proposed reduction of the SLMCPR values is based upon previously approved methodologies and does not involve changes to the plant hardware or its operating characteristics. As a result, no new failure modes are being introduced. Therefore, the change does not introduce a new or different kind of accident from those previously evaluated.
E-3
- 3. Does the proposed amendment involve a significant reduction in the margin of safety?
Response: No The margin of safety is established through the design of plant structures, systems, and components, and through the parameters for safe operation and setpoints of equipment relied upon to respond to transients and design basis accidents. The proposed change in SLMCPR does not change the requirements governing operation or availability of safety equipment assumed to operate to preserve the margin of safety. The change does not alter the behavior of the plant equipment.
The reduction of the SLMCPR values does not change the requirement that no more than 0.1% of fuel rods in the core experience boiling transition during normal operation and anticipated operational occurrences. Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Based on the above, TVA concludes the proposed amendment does not involve a significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.
4.4 CONCLUSION
S The proposed reduction of the TS 2.1.1.2 SLMCPR values are acceptable based on the following:
);>
A BFN, Unit 3 specific analysis of the SLMCPR values has been completed to demonstrate the adequacy of the revised SLMCPR values. The analysis utilized the NRC-approved AREVA SAFLIM3D methodology listed in TS 5.6.5.b of the BFN, Unit 3 Technical Specifications as approved in Reference 1.
);>
The SLMCPR values have been chosen conservatively to ensure that no more than 0.1% of rods experience boiling transition.
);>
The modification of the SLMCPR values does not require any plant modifications that could affect the behavior of the plant during normal, transient, or accident conditions.
Based on the considerations discussed above, (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.
5.0 ENVIRONMENTAL CONSIDERATION
A review has determined the proposed amendment would change a requirement with respect to the installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change a surveillance requirement. However, the proposed amendment does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure.
E-4
Accordingly, the proposed amendment meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed amendment.
6.0 REFERENCES
- 1. Letter from NRC to TVA, "Browns Ferry Nuclear Plant, Units 1, 2, and 3-Issuance of Amendments Regarding Technical Specifications (TS) Change TS-478 Addition of Analytical Methodologies toTS 5.6.5 and Revision of TS 2.1.1.2 for Unit 2 (TAC NOS. MF0877, MF0878, and MF0879)," dated July 31, 2014 (ML14108A334)
- 2. Letter from TVA to NRC, "Technical Specification Change TS-478-Addition of Analytical Methodologies toTS 5.6.5 for Browns Ferry 1, 2, and 3, and Revision of TS 2.1.1.2 for Browns Ferry Unit 2 in Support of Atrium 10XM Fuel Use at Browns Ferry," dated February 28, 2013 (ML13070A307)
- 3. ANP-10307PA, Revision 0, "AREVA MCPR Safety Limit Methodology for Boiling Water Reactors," AREVA NP Inc., June 2011 E-5 Proposed Technical Specification Page Markups
2.0 SAFETY LIMITS (Sls) 2.1 Sls 2.1.1 Reactor Core Sls 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow
< 1 0% rated core flow:
THERMAL POWER shall be s 25% RTP.
SLs 2.0 2.1.1.2 With the reactor steam dome pressure ~ 785 psig and core flow T 08
~ 10% rated core flow: ~
k::' ~
MCPR shall be ~ 4.00 for two recirculation loop operation or~ h1-4 I for single loop operation.
2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.
2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be s 1325 pstg.
2.2 SL Violations With any SL vioJation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:
2.2.1 Restore compliance with atl Sls; and 2.2.2 Insert all fnsertabte control rods.
BFN-UNIT3 2.0-1 Amendment No. 216,234.246 Proposed Retyped Technical Specifications Pages
2.0 SAFETY LIMITS (Sls) 2.1 Sls 2.1.1 Reactor Core Sls Sls 2.0 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow
< 1 0% rated core flow:
THERMAL POWER shall be~ 25% RTP.
2.1.1.2 With the reactor steam dome pressure;::: 785 psig and core flow
- 10% rated core flow
MCPR shall be ;::: 1.06 for two recirculation loop operation or
- 1.08 for single loop operation.
2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.
2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be ~ 1325 psig.
2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:
2.2.1 Restore compliance with all Sls; and 2.2.2 Insert all insertable control rods.
BFN-UNIT 3 2.0-1 Amendment No.~.~.~.
Proprietary Information Withhold Under 10 CFR 2.390(d)(1)
Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology (Proprietary)- AREVA FS1-0020053 Revision 1 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology (Non-proprietary)- AREVA FS1-0020054 Revision 1
CW01L Rev. 4.2 - 12/12/14 This text shall no be visible - Adjust frames over to ensure signature block will completely cover this text This text shall no be visible - Adjust frames over to ensure signature block will completely cover this text IDENTIFICATION REVISION AREVA Front End BG Fuel BU FS1-0020054 1.0 TOTAL NUMBER OF PAGES: 18 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology ADDITIONAL INFORMATION:
BFE3 Cycle 18 PROJECT DISTRIBUTION TO PURPOSE OF DISTRIBUTION HANDLING Restricted AREVA CATEGORY EIR - Engineering Information Report STATUS ROLES NAMES DATES ORGANIZATIONS SIGNATURES AUTHOR REVIEWER APPROVER WANG Peng, MOOSE James TYLINSKI Scott, TOUVANNAS George SCHNEPP Robert, MEGINNIS Alan RELEASE DATA:
Exportkennzeichnung AL: 0E001 ECCN: 0E001 Die mit "AL ungleich N" gekennzeichneten Güter unterliegen bei der Ausfuhr aus der EU bzw.
innergemeinschaftlichen Verbringung der europischen bzw. deutschen Ausfuhrgenehmigungspflicht. Die mit "ECCN ungleich N" gekennzeichneten Güter unterliegen der US-Reexportgenehmigungspflicht. Auch ohne Kennzeichen, bzw. bei Kennzeichen "AL: N" oder "ECCN: N", kann sich eine Genehmigungspflicht, unter anderem durch den Endverbleib und Verwendungszweck der Güter, ergeben.
SAFETY RELATED DOCUMENT:
<
Export classification AL: 0E001 ECCN: 0E001 Goods labeled with AL not equal to N are subject to European or German export authorization when being exported within or out of the EU. Goods labeled with ECCN not equal to N are subject to US reexport authorization. Even without a label, or with label AL: N or ECCN: N, authorization may be required due to the final whereabouts and purpose for which the goods are to be used.
CHANGE CONTROL RECORDS:
This document, when revised, must be reviewed or approved by the following regions:
France:
USA:
Germany:
N Y
N This document is electronically approved. Records regarding the signatures are stored in the Fuel BU Document Database. Any attempt to modify this file may subject employees to civil and criminal penalties. EDM Object Id:
- Release date (YYYY/MM/DD) :
[Western European Time]
Role Name Date (YYYY/MM/DD) Organization
HE
- ULWHU
- $1*3HQJ
$5(9$,QF
- ULWHU 0226(-DPHV
$5(9$,QF
5HYLHZHU 7</,16.,6FRWW
$5(9$,QF
5HYLHZHU 7289$11$6*HRUJH
$5(9$,QF
$SSURYHU
,1*+$0-HUU\\
$5(9$,QF
$SSURYHU 0(*,11,6$ODQ
$5(9$,QF
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 2/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page REVISIONS REVISION DATE EXPLANATORY NOTES 1.0 See 1st page release date Initial issue.
This is the non-proprietary version of FS1-0020053.
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 3/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page Documentation of Multiple Analysts, Reviewers, or Approvers (Reference FSOP-7 Appendix 2)
Full Name & Title (printed or typed)
Role:
W = Writer/Analyst R = Reviewer A = Approver Signature Date Pages/Sections Prepared/Reviewed/
Approved Type of Review (applies to Reviewers only):
T = Technical D = Documentation B = Both Peng WANG Engineer W
N/A-Approval of document in electronic workflow constitutes acceptance.
N/A All except Figure 1, Figures 5-9 James MOOSE Engineer W
N/A-Approval of document in electronic workflow constitutes acceptance.
N/A Figure 1, Figures 5-9 Scott TYLINSKI, Supervisor Engineer R
N/A-Approval of document in electronic workflow constitutes acceptance.
N/A All except Figure 1, Figures 5-9 B
George TOUVANNAS Engineer R
N/A-Approval of document in electronic workflow constitutes acceptance.
N/A Figure 1, Figures 5-9 B
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 4/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page
- 1.
PURPOSE Reference 1 presents an AREVA methodology for determining the safety limit minimum critical power ratio (SLMCPR) that was approved by the NRC. The methodology is an update or extension of the previously approved methodology presented in Reference 2. The SLMCPR methodology was updated to incorporate full implementation of the ACE critical power correlation (References 3 and 4), a realistic fuel channel bow model (Reference 5), and expanded coupling with the MICROBURN-B2 core simulator (Reference 6). More detailed descriptions of these improvements are discussed in Reference 1. The purpose of this report is to provide SLMCPR results for Browns Ferry Unit 3 Cycle 18 using the Reference 1 methodology to support a change in the list of approved methodologies in the Technical Specifications and also a change in the Technical Specification SLMCPR values for two-loop operation (TLO) and single-loop operation (SLO).
- 2.
METHODOLOGY The analysis presented in this document used the methodology presented in Reference 1. The SLMCPR is defined as the minimum value of the critical power ratio which ensures that at least 99.9% of the fuel rods in the core are expected to avoid boiling transition during normal operation or an anticipated operational occurrence (AOO). The SLMCPR is determined using a statistical analysis that employs a Monte Carlo process that perturbs key input parameters used in the calculation of MCPR. The set of uncertainties used in the statistical analysis include both fuel-related and plant-related uncertainties.
The SLMCPR analysis is performed with a power distribution that conservatively represents expected reactor operating states that could both exist at the operating limit MCPR (OLMCPR) and produce a MCPR equal to the SLMCPR during an AOO. [
]
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 5/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page In the AREVA methodology, the effects of channel bow on the critical power performance are accounted for in the SLMCPR analysis. Reference 1 discusses the application of a realistic channel bow model.
3.
ANALYSIS The final core design and step-through, developed by AREVA to meet the operating requirements specified by TVA, was used in the BFE3-18 MCPR safety limit analysis. The BFE3-18 design supports licensed rated power of 3,458 MWt and operation to licensing end of cycle (EOC) cycle exposure of approximately 18,039.5 MWd/MTU. The design includes extensions for final feedwater temperature reduction (FFTR) and coastdown. Figure 1 presents the core loading, the cycle the fuel was originally loaded, and the number of assemblies. The BFE3-18 core is made up of ATRIUM' 10XM* and ATRIUM-10 fuel. Analyses were performed [
] for the Browns Ferry power/flow map for MELLLA operation as shown in Figure 2. The radial power distribution [
] is presented in Figure 3 and Figure 4.
The calculated fast fluence gradients for the BFE3-18 core design have been compared to the upper and lower bounds of the channel bow database. As shown in Figure 5, the BFE3-18 reference core design remains bounded by the upper/lower bound of the channel bow database [
]. The channel bow model uncertainty for the assemblies that experience fluence gradients outside the bounds of the measurement database was augmented with the same approach as demonstrated in the Response to SNPB RAI-6 in Reference 9.
The ACE/ATRIUM 10XM critical power correlation (References 3 and 4) is used for the ATRIUM 10XM fuel while the SPCB critical power correlation (Reference 7) is used for the ATRIUM-10. The fuel-and plant-related uncertainties used in the BFE3-18 SLMCPR analysis are presented in Table 1. The radial and nodal power uncertainties used in the analysis include the effects of up to 40% of the TIP channels out-of-service, up to 50% of the LPRMs out-of-service, and a 2500 effective full power hour (EFPH) LPRM calibration interval.
[
]
ATRIUM is a trademark of AREVA Inc.
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 6/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page
[
]
The BFE3-18 SLMCPR analysis supports a TLO SLMCPR of 1.03 and an SLO SLMCPR of 1.05. Table 2 presents a summary of the analysis results including the SLMCPR and the percentage of rods expected to experience boiling transition. The percentages of the total number of fuel rods predicted to experience boiling transition in the overall Monte Carlo statistical evaluation associated with each nuclear fuel type are presented in Table 3. The results are for the [
]. The BFE3-18 fuel design is presented in Figures 7 through 9.
4.
DISCUSSION OF RESULTS Compared to the current TLO and SLO SLMCPR limits using the Reference 2 methodology, results show a significant decrease in both the TLO and SLO SLMCPR limits with the Reference 1 methodology. The SLMCPR differences are primarily a result of the following differences in the methodologies:
x Implementation of the realistic channel bow model x
Explicit use of the [
] as a result of the expanded coupling with MICROBURN-B2 The improved SLMCPR results with the Reference 1 methodology are consistent with the results presented in Tables 4-1 and 4-3 of Reference 1.
5.
REFERENCES 1.
ANP-10307PA Revision 0, AREVA MCPR Safety Limit Methodology for Boiling Water Reactors, AREVA NP, June 2011.
2.
ANF-524(P)(A) Revision 2 and Supplements 1 and 2, ANF Critical Power Methodology for Boiling Water Reactors, Advanced Nuclear Fuels Corporation, November 1990.
3.
ANP-10298PA Revision 0, ACE/ATRIUM 10XM Critical Power Correlation, AREVA NP, March 2010.
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 7/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page 4.
ANP-3140(P) Revision 0, Browns Ferry Units 1, 2, and 3 Improved K-factor Model for ACE/ATRIUM 10XM Critical Power Correlation, AREVA NP, August 2012.
5.
BAW-10247PA Revision 0, Realistic Thermal-Mechanical Fuel Rod Methodology for Boiling Water Reactors, AREVA NP, February 2008.
6.
EMF-2158(P)(A) Revision 0, Siemens Power Corporation Methodology for Boiling Water Reactors:
Evaluation and Validation of CASMO-4 / MICROBURN-B2, Siemens Power Corporation, October 1999.
7.
EMF-2209(P)(A) Revision 3, SPCB Critical Power Correlation, AREVA NP, September 2009.
8.
Letter, H. Donald Curet (AREVA) to H.J. Richings (USNRC), POWERPLEX£ Core Monitoring:
Failed or Bypassed Instrumentation and Extended Calibration, HDC:96:012, May 6, 1996.
(38-9043714-000).
9.
ANP-3248(P) Revision 1, AREVA RAI Response for Browns Ferry ATRIUM 10XM Fuel Transition, September 2013.
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 8/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page Table 1 Fuel-and Plant-Related Uncertainties MCPR Safety Limit Analyses Parameter Standard Deviation Fuel-Related Uncertainties
[
]
Plant-Related Uncertainties Feedwater flow rate 1.8%
Feedwater temperature 0.8%
Core pressure 0.7%
Total core flow rate TLO SLO 2.5%
6.0%
[
]
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 9/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page Table 2 Results Summary for MCPR Safety Limit Analysis SLMCPR Percentage of Rods in Boiling Transition TLO - 1.03 0.0662 SLO - 1.05 0.0662 Table 3 Contribution of Total Predicted Rods in BT by Nuclear Fuel Type Nuclear Fuel Type Fuel Design Burnup Status Contribution of Total Rods Predicted to be in BT (%)
[
]
[
]
12 ATRIUM-10 Twice burned
[
13 ATRIUM-10 Twice burned 14 ATRIUM-10 Twice burned 15 ATRIUM-10 Twice burned 16 ATRIUM-10 Once burned 17 ATRIUM-10 Once burned 18 ATRIUM-10 Once burned 19 ATRIUM 10XM Fresh 20 ATRIUM 10XM Fresh 21 ATRIUM 10XM Fresh
]
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 10/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page 12 13 13 14 14 12 13 13 12 12 13 13 13 12 12 15 15 15 15 12 12 15 15 12 12 15 15 15 12 12 12 14 15 16 16 19 16 19 18 16 16 18 19 16 19 16 16 12 13 12 13 16 18 16 19 19 19 17 19 19 19 19 17 19 19 19 16 18 16 14 12 12 12 16 20 19 17 20 20 20 17 17 20 20 20 17 19 20 16 17 15 12 12 13 12 15 19 19 19 16 20 18 20 16 21 21 16 20 18 20 16 19 19 19 15 12 13 12 13 16 17 19 17 20 16 21 16 21 17 21 16 16 21 17 21 16 21 16 20 17 19 12 16 13 12 15 18 16 19 20 16 21 16 21 18 20 16 21 21 16 20 18 21 16 21 16 20 19 16 18 15 12 12 14 16 16 20 19 16 21 16 21 16 20 18 20 16 16 20 18 20 16 21 16 21 16 19 20 16 16 15 12 13 15 16 19 19 16 21 16 21 16 20 18 20 18 20 20 18 20 18 20 16 21 16 21 16 19 19 16 15 13 13 15 19 19 17 20 16 21 16 20 16 20 16 20 16 16 20 16 20 16 20 16 21 16 20 17 19 19 15 13 13 15 16 19 20 18 21 18 20 18 20 16 20 18 20 20 18 20 16 20 18 20 18 21 18 20 19 16 15 14 12 12 19 17 20 20 17 20 18 20 16 20 16 20 18 18 20 16 20 16 20 18 20 17 20 20 17 19 12 14 12 12 18 19 20 16 21 16 20 18 20 18 20 16 20 20 16 20 18 20 18 20 16 21 16 20 19 18 12 12 13 15 16 19 17 21 16 21 16 20 16 20 18 20 16 16 20 18 20 16 20 16 21 16 21 17 19 16 15 13 13 15 16 19 17 21 16 21 16 20 16 20 18 20 16 16 20 18 20 16 20 16 21 16 21 17 19 16 15 13 12 12 18 19 20 16 21 16 20 18 20 18 20 16 20 20 16 20 18 20 18 20 16 21 16 20 19 18 15 12 14 12 19 17 20 20 17 20 18 20 16 20 16 20 18 18 20 16 20 16 20 18 20 17 20 20 17 19 12 12 14 15 16 19 20 18 21 18 20 18 20 16 20 18 20 20 18 20 16 20 18 20 18 21 18 20 19 16 15 13 13 15 19 19 17 20 16 21 16 20 16 20 16 20 16 16 20 16 20 16 20 16 21 16 20 17 19 19 15 13 13 15 16 19 19 16 21 16 21 16 20 18 20 18 20 20 18 20 18 20 16 21 16 21 16 19 19 16 15 13 12 12 16 16 20 19 16 21 16 21 16 20 18 20 16 16 20 18 20 16 21 16 21 16 19 20 16 16 12 12 12 15 18 16 19 20 16 21 16 21 18 20 16 21 21 16 20 18 21 16 21 16 20 19 16 18 15 12 13 16 12 19 17 20 16 21 16 21 17 21 16 16 21 17 21 16 21 16 20 17 19 17 16 13 12 13 12 15 19 19 19 16 20 18 20 16 21 21 16 20 18 20 16 19 19 19 12 12 13 12 12 12 17 16 20 19 17 20 20 20 17 17 20 20 20 17 19 20 16 14 12 12 14 16 18 16 19 19 19 17 19 19 19 19 17 19 19 19 16 18 16 14 12 13 15 16 16 19 16 19 18 16 16 18 19 16 19 16 16 15 14 12 15 12 15 12 15 12 12 15 15 12 12 15 15 15 15 12 12 13 13 13 12 12 13 13 12 14 14 13 13 15 Nuclear Fuel Type Fuel Description Cycle Loaded Number of Assemblies 12 ATRIUM-10 16 70 13 ATRIUM-10 16 39 14 ATRIUM-10 16 15 15 ATRIUM-10 16 48 16 ATRIUM-10 17 176 17 ATRIUM-10 17 40 18 ATRIUM-10 17 72 19 ATRIUM 10XM 18 88 20 ATRIUM 10XM 18 152 21 ATRIUM 10XM 18 64 Figure 1 Browns Ferry Unit 3 Cycle 18 Core Loading Map
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 11/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page Figure 2 Browns Ferry Power / Flow Map
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 12/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page 0.166 0.213 0.244 0.264 0.263 0.239 0.248 0.225 0.346 0.440 0.498 0.519 0.482 0.474 0.495 0.155 0.282 0.433 0.620 0.743 0.989 0.845 1.008 0.857 0.799 0.270 0.508 0.712 0.820 1.127 1.202 1.225 1.016 1.209 1.189 0.276 0.440 0.611 0.856 1.171 1.255 1.085 1.320 1.331 1.315 1.076 0.164 0.286 0.454 0.648 1.063 1.201 1.275 1.075 1.325 1.154 1.358 1.113 1.318 0.285 0.533 0.732 1.078 1.011 1.285 1.086 1.311 1.114 1.338 1.130 1.347 1.134 0.241 0.443 0.732 0.881 1.221 1.295 1.111 1.325 1.118 1.345 1.172 1.383 1.150 1.392 0.170 0.347 0.629 0.840 1.190 1.296 1.108 1.346 1.137 1.368 1.152 1.410 1.219 1.434 1.193 0.218 0.447 0.751 1.140 1.270 1.092 1.341 1.142 1.377 1.170 1.426 1.225 1.456 1.243 1.463 0.246 0.511 0.995 1.210 1.095 1.339 1.126 1.361 1.164 1.433 1.207 1.473 1.229 1.476 1.216 0.253 0.520 0.840 1.229 1.327 1.163 1.348 1.178 1.420 1.233 1.477 1.239 1.490 1.273 1.483 0.245 0.479 1.007 1.011 1.333 1.361 1.133 1.386 1.221 1.461 1.232 1.500 1.243 1.499 1.274 0.235 0.474 0.858 1.209 1.314 1.110 1.344 1.149 1.428 1.242 1.485 1.286 1.502 1.235 1.483 0.248 0.489 0.798 1.189 1.065 1.313 1.130 1.377 1.167 1.437 1.215 1.486 1.276 1.483 1.192 0.249 0.494 0.799 1.189 1.074 1.313 1.128 1.376 1.164 1.436 1.215 1.486 1.272 1.482 1.194 0.238 0.473 0.855 1.208 1.314 1.109 1.342 1.143 1.425 1.239 1.485 1.286 1.500 1.230 1.482 0.261 0.478 1.006 1.015 1.332 1.359 1.131 1.383 1.219 1.458 1.232 1.500 1.244 1.497 1.269 0.262 0.508 0.837 1.227 1.324 1.161 1.345 1.176 1.418 1.232 1.476 1.228 1.488 1.271 1.481 0.243 0.501 0.989 1.205 1.088 1.335 1.122 1.358 1.161 1.431 1.215 1.471 1.226 1.474 1.213 0.212 0.437 0.743 1.132 1.263 1.082 1.336 1.136 1.374 1.168 1.424 1.224 1.455 1.240 1.459 0.162 0.313 0.618 0.829 1.177 1.286 1.102 1.341 1.134 1.364 1.148 1.408 1.217 1.433 1.187 0.218 0.427 0.710 0.860 1.204 1.285 1.099 1.320 1.111 1.341 1.169 1.382 1.158 1.388 0.266 0.504 0.602 1.059 1.002 1.281 1.083 1.306 1.107 1.333 1.125 1.344 1.133 0.151 0.267 0.435 0.643 1.067 1.204 1.273 1.071 1.318 1.148 1.352 1.109 1.312 0.271 0.443 0.719 0.864 1.172 1.250 1.077 1.313 1.323 1.307 1.063 0.292 0.524 0.717 0.818 1.121 1.194 1.216 1.001 1.201 1.183 0.160 0.279 0.431 0.615 0.735 0.978 0.834 0.997 0.847 0.795 0.253 0.319 0.422 0.458 0.506 0.472 0.466 0.489 0.162 0.205 0.234 0.244 0.238 0.232 0.245 0.248 0.234 0.242 0.249 0.241 0.211 0.163 0.493 0.469 0.475 0.511 0.498 0.441 0.329 0.221 0.798 0.852 1.002 0.841 0.986 0.741 0.614 0.388 0.273 0.161 1.188 1.205 1.005 1.221 1.199 1.126 0.819 0.714 0.523 0.295 1.067 1.312 1.328 1.318 1.081 1.254 1.174 0.866 0.722 0.476 0.276 1.317 1.112 1.357 1.151 1.324 1.075 1.277 1.208 1.071 0.645 0.440 0.270 0.152 1.137 1.349 1.129 1.338 1.111 1.311 1.086 1.285 1.005 1.064 0.613 0.506 0.268 1.393 1.162 1.386 1.172 1.345 1.115 1.324 1.101 1.289 1.209 0.864 0.712 0.422 0.225 1.192 1.438 1.222 1.412 1.152 1.368 1.136 1.345 1.104 1.290 1.181 0.831 0.623 0.356 0.169 1.463 1.244 1.459 1.226 1.428 1.170 1.377 1.138 1.340 1.086 1.267 1.136 0.748 0.448 0.218 1.215 1.477 1.228 1.474 1.216 1.434 1.162 1.361 1.124 1.338 1.091 1.209 0.994 0.501 0.247 1.483 1.271 1.490 1.230 1.478 1.234 1.421 1.177 1.348 1.161 1.328 1.230 0.841 0.523 0.265 1.269 1.499 1.244 1.501 1.233 1.460 1.221 1.386 1.132 1.363 1.335 1.018 1.010 0.482 0.264 1.483 1.231 1.502 1.284 1.487 1.240 1.426 1.145 1.345 1.113 1.317 1.212 0.858 0.476 0.240 1.195 1.483 1.272 1.487 1.216 1.439 1.166 1.379 1.131 1.317 1.077 1.192 0.801 0.495 0.252 1.193 1.484 1.278 1.488 1.217 1.440 1.167 1.381 1.133 1.316 1.068 1.193 0.803 0.501 0.253 1.483 1.235 1.503 1.292 1.489 1.244 1.431 1.152 1.347 1.113 1.317 1.212 0.862 0.507 0.241 1.271 1.499 1.244 1.503 1.236 1.464 1.225 1.389 1.136 1.364 1.336 1.013 1.011 0.483 0.247 1.481 1.273 1.489 1.239 1.479 1.236 1.422 1.180 1.350 1.164 1.329 1.230 0.841 0.518 0.252 1.212 1.474 1.227 1.472 1.206 1.434 1.165 1.362 1.128 1.340 1.093 1.210 0.994 0.505 0.244 1.459 1.238 1.453 1.224 1.425 1.172 1.377 1.142 1.342 1.092 1.270 1.139 0.749 0.443 0.214 1.187 1.430 1.215 1.407 1.149 1.366 1.136 1.347 1.109 1.296 1.190 0.838 0.626 0.317 0.164 1.387 1.146 1.379 1.169 1.342 1.115 1.324 1.111 1.297 1.221 0.880 0.729 0.442 0.231 1.130 1.342 1.124 1.334 1.110 1.309 1.087 1.290 1.016 1.081 0.731 0.531 0.282 1.312 1.109 1.353 1.150 1.321 1.075 1.278 1.213 1.080 0.621 0.454 0.285 0.160 1.071 1.309 1.326 1.316 1.080 1.255 1.178 0.872 0.753 0.458 0.280 1.184 1.203 1.010 1.221 1.200 1.128 0.824 0.724 0.531 0.299 0.795 0.850 1.002 0.842 0.989 0.745 0.624 0.430 0.292 0.163 0.487 0.462 0.483 0.508 0.501 0.447 0.362 0.243 0.245 0.236 0.260 0.262 0.245 0.218 0.194 Figure 3 Radial Power Distribution Map for Browns Ferry Unit 3 Cycle 18 SLMCPR [
]
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 13/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page Figure 4 Radial Power Distribution for [
]
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 14/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page Figure 5 Channel Fluence Gradient Distribution for Browns Ferry Unit 3 Cycle 18
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 15/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page Figure 6 Browns Ferry Unit 3 Cycle 18 Reference Full Core Loading Pattern
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 16/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page 150.00" 6.00" XMLCT-0720L-0G0 144.00" 12.00" XMLCT-3955L-11G40-FCG 132.00" 18.00" XMLCT-4429L-11G50-FCG 114.00" 30.00" XMLCT-4429L-11G70-FCG 84.00" 6.00" XMLCP-4429L-11G70-FCG 78.00" 60.00" XMLCB-4429L-11G70-FCG 18.00" 12.00" XMLCB-4429L-11G50-FCG 6.00" 3.00" XMLCB-0720L-0G0 3.00" 3.00" XMLCP-0720L-0G0 0.00" Figure 7 Elevation View for the Fresh Fuel Reload Batch XMLC-4104B-11GV70 Fuel Assembly Design
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 17/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page 150.00" 6.00" XMLCT-0720L-0G0 144.00" 12.00" XMLCT-3950L-11G40-FCG 132.00" 12.00" XMLCT-4365L-11G60-FCG 120.00" 36.00" XMLCT-4417L-11G80-FCG 84.00" 6.00" XMLCP-4417L-11G80-FCG 78.00" 72.00" XMLCB-4423L-12G80-FCG 6.00" 3.00" XMLCB-0720L-0G0 3.00" 3.00" XMLCP-0720L-0G0 0.00" Figure 8 Elevation View for the Fresh Fuel Reload Batch XMLC-4092B-12GV80 Fuel Assembly Design
N° FS1-0020054 Rev. 1.0 Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology Handling: Restricted AREVA Page 18/18 AREVA - Fuel BU This document is subject to the restrictions set forth on the first or title page 150.00" 6.00" XMLCT-0720L-0G0 144.00" 12.00" XMLCT-4017L-11G40-FCG 132.00" 48.00" XMLCT-4017L-11G70-FCG 84.00" 6.00" XMLCP-4017L-11G70-FCG 78.00" 66.00" XMLCB-4389L-13GV70-FCG 12.00" 6.00" XMLCB-4388L-11G60-FCG 6.00" 3.00" XMLCB-0720L-0G0 3.00" 3.00" XMLCP-0720L-0G0 0.00" Figure 9 Elevation View for the Fresh Fuel Reload Batch XMLC-3950B-13GV70 Fuel Assembly Design Affidavit for Withholding of AREVA Report FS1-0020053, Rev. 1 (Attachment 3) from Public Disclosure
STATE OF WASHINGTON COUNTY OF BENTON ss.
- 1.
My name is Alan B. Meginnis. I am Manager, Product Licensing, for AREVA Inc. and as such I am authorized to execute this Affidavit.
- 2.
I am familiar with the criteria applied by AREVA to determine whether certain AREVA information is proprietary. I am familiar with the policies established by AREVA to ensure the proper application of these criteria.
- 3.
I am familiar with the AREVA information contained in the report FS 1-0020053 Revision 1, "Browns Ferry Unit 3 Cycle 18 MCPR Safety Limit Analysis With SAFLIM3D Methodology," dated January 2015 and referred to herein as "Document."
Information contained in this Document has been classified by AREVA as proprietary in accordance with the policies established by AREVA for the control and protection of proprietary and confidential information.
- 4.
This Document contains information of a proprietary and confidential nature and is of the type customarily held in confidence by AREVA and not made available to the public. Based on my experience, I am aware that other companies regard information of the kind contained in this Document as proprietary and confidential.
- 5.
This Document has been made available to the U.S. Nuclear Regulatory Commission in confidence with the request that the information contained in this Document be withheld from public disclosure. The request for withholding of proprietary information is made in accordance with 10 CFR 2.390. The information for which withholding from disclosure is
requested qualifies under 10 CFR 2.390(a)(4) 'Trade secrets and commercial or financial information."
- 6.
The following criteria are customarily applied by AREVA to determine whether information should be classified as proprietary:
(a)
The information reveals details of AREVA's research and development plans and programs or their results.
(b)
Use of the information by a competitor would permit the competitor to significantly reduce its expenditures, in time or resources, to design, produce, or market a similar product or service.
(c)
The information includes test data or analytical techniques concerning a process, methodology, or component, the application of which results in a competitive advantage for AREVA.
(d)
The information reveals certain distinguishing aspects of a process, methodology, or component, the exclusive use of which provides a competitive advantage for AREVA in product optimization or marketability.
(e)
The information is vital to a competitive advantage held by AREVA, would be helpful to competitors to AREVA, and would likely cause substantial harm to the competitive position of AREV A.
The information in the Document is considered proprietary for the reasons set forth in paragraphs 6(b), 6(d) and 6(e) above.
- 7.
In accordance with AREVA's policies governing the protection and control of information, proprietary information contained in this Document have been made available, on a limited basis, to others outside AREVA only as required and under suitable agreement providing for nondisclosure and limited use of the information.
- 8.
AREVA policy requires that proprietary information be kept in a secured file or area and distributed on a need-to-know basis.
- 9.
The foregoing statements are true and correct to the best of my knowledge, information, and belief.
I SUBSCRIBED before me this 3 0 day of J,._ ~a
' 2015.
Susan K. McCoy NOTARY PUBLIC, STATE OF WASHIN N
MY COMMISSION EXPIRES: 1/14/2016