GO2-15-024, Withdrawal of Inservice Inspection (ISI) Program Request 3ISI-16

From kanterella
(Redirected from ML15069A435)
Jump to navigation Jump to search

Withdrawal of Inservice Inspection (ISI) Program Request 3ISI-16
ML15069A435
Person / Time
Site: Columbia 
Issue date: 02/18/2015
From: Javorik A
Energy Northwest
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GO2-15-024
Download: ML15069A435 (2)


Text

Alex, ENERGYVice President, Engi P.O. Box 968, Mail Drop NOR A

TRichland, WA 9935:

NORTH W ~E TPh.

509-377-8555 F. 509-37 aljavorik@ energy-northwe G02-1 5-024 FEB 18 2015 10CFR 5C U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 j

Subject:

COLUMBIA GENERATiNG STATION, DOCKET NO. 50-397; WITHDRAWAL OF INSERVICE INSPECTION (ISI) PROGRAM REQUEST 31S1-16 Javorik ieering PE20 2-0968 7-4317 st.com

).55a

References:

(1) Letter G02-14-090 dated June 24, 2014, A.L. Javorik (Energy Northwest) to NRC, "Inservice Inspection (ISI) Program Request 31S1-16" (2) Enforcement Guidance Memorandum (EGM) 14-003 dated January 16, 2015, "Enforcement Discretion Not to Cite Violations Involving Bolt and Stud Non-Destructive Examination Qualifications Programs, While Rulemaking Changes are Being Developed" (ML14169A582)

Dear Sir or Madam:

In Reference 1, Energy Northwest submitted Request 31S1-16 to.allow continued use of the Performance Demonstration Initiative (PDI) bolting program administered by Electrical Power Research Institute (EPRI) for the American Society of Mefhanical Engineers (ASME) "Boiler and Pressure Vessel Code," required bolting examinations at Columbia Generating Station (Columbia).

As documented in Reference 2, the NRC grants enforcement discretion and will not cite licensees for violations of 10 CFR 50.55a or other quality-assurance program requirements related to the use of bolt and stud Non-Destructive Examination (NDE) procedures, personnel and equipment qualified through the PDI to meet the requirements of Supplement 8 to Mandatory Appendix VIII to Section XI of the ASME Code. Upon consideration of Reference 2, Energy Northwest respectfully withdraws Request 31S1-16.

No new regulatory commitments are being made with this submittal.

Should you have any questions or require additional information regarding this matter, please contact Ms. L. L. Williams, Licensing Supervisor, at (509)377-8148.

COLUMBIA GENERATING STATION, DOCKET NO. 50-397 WITHDRAWAL OF INSERVICE INSPECTION (ISI) PROGRAM REQUEST 31S1-16 Page 2 Executed this 11 day of 20..

Respectfully, A. L. Javorik Vice President, Engineering cc:

NRC RIV Regional Administrator NRC NRR Project Manager NRC Sr. Resident Inspector - 988C CD Sonoda - BPA/1 399 (email)

.WA Horin - Winston & Strawn (email)

I1