ML15056A518
ML15056A518 | |
Person / Time | |
---|---|
Issue date: | 02/25/2015 |
From: | Glenn Tuttle NRC/NMSS/DFCSE/MCAB |
To: | |
Tuttle G | |
References | |
Download: ML15056A518 (2) | |
Text
Material Control and Accounting Regulatory Guides Draft Regulatory Guide (DG) Previous Regulatory Guide(s) to be updated/consolidated DG-5049 - Management Review of Nuclear Regulatory Guide (RG) 5.51 - Management Review of Nuclear Material Control and Accounting Systems Material Control and Accounting Systems DG-5050 - Selection of Material Balance RG 5.26 - Selection of Material Balance Areas and Item Control Areas Areas and Item Control Areas DG-5051 - Shipping, Receiving, and Internal RG 5.28 - Evaluation of Shipper-Receiver Differences in the Transfer Transfer of Special Nuclear Material of Special Nuclear Materials (Endorses ANSI N15.17)
RG 5.49 - Internal Transfers of Special Nuclear Material RG 5.57 - Shipping and Receiving Control of Strategic Special Nuclear Material DG-5052 - Determination Of Uranium or RG 5.4 - Standard Analytical Methods for the Measurement of Plutonium: Methods Based on the Analysis Uranium Tetrafluoride (UF4) and Uranium Hexafluoride (UF6) of Samples (Endorses ANSI N15.6 and ANSI N15.7)
RG 5.5 - Standard Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Uranium Dioxide Powders and Pellets (Endorses ASTM Standard C 696-72)
RG 5.39 - General Methods for the Analysis of Uranyl Nitrate Solutions for Assay, Isotopic Distribution, and Impurity Determinations (Endorses ASTM Standard C-799)
RG 5.48 - Design Considerations - Systems for Measuring the Mass of Liquids RG 5.58 - Considerations for Establishing Traceability of Special Nuclear Material Accounting Measurements
Material Control and Accounting Regulatory Guides Draft Regulatory Guide (DG) Previous Regulatory Guide(s) to be updated/consolidated DG-5053 - Determination of Uranium or RG 5.9 - Guidelines for Germanium Spectroscopy Systems for Plutonium: Nondestructive Assay Methods Measurement of Special Nuclear Material RG 5.11 - Nondestructive Assay of Special Nuclear Material Contained in Scrap and Waste RG 5.21 - Nondestructive Uranium-235 Enrichment Assay by Gamma Ray Spectrometry RG 5.23 - In Situ Assay of Plutonium Residual Holdup RG 5.34 - Nondestructive Assay for Plutonium in Scrap Material by Spontaneous Fission Detection RG 5.37 - In Situ Assay of Enriched Uranium Residual Holdup RG 5.38 - Nondestructive Assay of High-Enrichment Uranium Fuel Plates by Gamma Ray Spectrometry RG 5.53 - Qualification, Calibration, and Error Estimation Methods for Nondestructive Assay (Endorses ANSI N15.20)
DG-5054 - Design Considerations to RG 5.8 - Design Considerations for Minimizing Residual Holdup of Minimize Residual Holdup of Special Special Nuclear Material in Drying and Fluidized Bed Operations Nuclear Material in Process Equipment RG 5.25 - Design Considerations for Minimizing Residual Holdup of Special Nuclear Material in Equipment for Wet Process Operations RG 5.42 - Design Considerations for Minimizing Residual Holdup of Special Nuclear Material in Equipment for Dry Process Operations DG-5055 - Statistical Concepts for Material RG 5.3 - Statistical Terminology and Notation for Special Nuclear Control and Accounting (Tentative) Materials Control and Accountability (Endorses ANSI N15.5)
RG 5.18 - Limit of Error Concepts and Principles of Calculation in Nuclear Materials Control (Endorses ANSI N15.16)
RG 5.22 - Assessment of the Assumption of Normality (Employing Individual Observed Values) (Endorses ANSI N15.15)
RG 5.36 - Recommended Practice for Dealing with Outlying Observations (Endorses ASTM Standard E178-74)
DG-5056 - Material Control and Accounting RG 5.13 - Conduct of Nuclear Material Physical Inventories Physical Inventories and Material Balances RG 5.33 - Statistical Evaluation of Material Unaccounted For