Pre-Submittal Public Meeting with Energy Northwest to Discuss Upcoming Relief Request Regarding Reactor Water Cleanup System
ML15054A473
Person / Time
Site: Columbia 
(NPF-021)
Issue date: 02/23/2015
From: Reddemann M
Energy Northwest
To: Andrea George
Plant Licensing Branch IV
George A
References
TAC MF5679
Download: ML15054A473 (26)


Text

Relief Request for Reactor Water Cleanup (RWCU) System Components Energy Northwest February 24, 2015

AGENDA Introduction

Background

Relief Request Technical Evaluation Conclusion 2

INTRODUCTION Components in the non-safety related portions of the Reactor Water Cleanup System which do not conform to ASME design requirements (due to historical reclassification activities) perform with an acceptable level of safety and quality for extended in-plant operation 3

BACKGROUND: RWCU System Description Continuously purifies reactor water during all modes of reactor operation Takes suction from the inlet of each reactor recirculation pump and from the reactor pressure vessel bottom head and returns processed water to reactor pressure vessel, main condenser, or radwaste Equipment located in the reactor building includes main system pumps and regenerative and non-regenerative heat exchangers Equipment located in the radwaste building includes filter-demineralizers and supporting equipment 4

BACKGROUND: History of RWCU system classification Non-safety related portion of system originally classified Quality Group C as defined in Regulatory Guide (RG) 1.26 Rev. 3 ASME Section III, Class 3 (ASME III/3) 1995: Demineralizer portion of the system difficult to operate due to excessive boundary valve leakage Sought new valve design to improve system reliability ASME valves un-reliable and difficult to maintain due to parts availability High dose impact for repeat maintenance on ASME valves EN identified a highly reliable valve, but the valve was not available with ASME certification 5

BACKGROUND: History (continued) 1995: EN initiated reclassification of non-safety related portion of RWCU system in accordance with Regulatory Guide (RG) 1.26 Rev. 3 by taking advantage of note 6:

Components in influent lines may be classified as Group D provided they are capable of being isolated from the reactor coolant pressure boundary by an additional valve which has high leaktight integrity.

Reclassified portions of system to B31.1 (Group D) with the new code break set one valve beyond the credited pressure boundary 1996: NRC Inspection Report 50-397/96-11 identifies weaknesses with 50.59 safety evaluation (SE) supporting reclassification but concludes SE is adequate 6

BACKGROUND: History (continued) 1998: NRC challenged the conclusion that the requirements of RG 1.26 note 6 were met 1998: In response, the 50.59 safety evaluation was rewritten and concluded that NRC approval was not required 2013: NRC issued a violation for failure to obtain NRC approval of the portions of the RWCU system that were reclassified (IR 50-397/13 ML13206A131) 7

BACKGROUND: RWCU System Unaffected Components Safety related ASME valves, piping, hangers and instruments were not included in the reclassification Non-safety related heat exchangers were not included in the reclassification Non-safety related ASME piping and hangers were not repaired or replaced 8

BACKGROUND: RWCU System Non-Conforming Components Removed strainer on the demineralizer filter inlet (replaced with ASME pipe and elbows) without ASME Section XI work plan Replaced the main RWCU pumps ASME sealless water-cooled motor assemblies with non-ASME assemblies Replaced 9 ASME globe valve pressure boundary parts with ANSI parts Replaced 29 ASME ball valves with ANSI B31.1 plug valves 9

BACKGROUND: Corrective Actions Documented violation in a condition report Identified population of non-conforming components Issued Functionality Determination for continued operation Completed Apparent Cause Evaluation and identified corrective actions 10

BACKGROUND: Corrective Actions (continued)

Design documents changed to restore original Quality Group C classification Completed nondestructive examination (NDE) of ANSI welds with no recordable indications observed Initiated project to identify and purchase suitable replacement ASME components Purchased spare ASME pump motor assembly Replaced two ANSI valves with ASME III/3 valves 11

RELIEF REQUEST: Applicable Code and Duration Columbia ASME Section XI Code is the 2001 Edition through the 2003 Addenda Relief requested from requirements of IWA-4221(b)(1):

Requires that an item used for repair/replacement activities meet the Construction Code to which the original item was constructed.

Relief is requested pursuant to 10 CFR 50.55a(z)(i) - the proposed alternative would provide an acceptable level of quality and safety Duration of request is for remaining period of the third inservice inspection interval ending December 12, 2015, and the fourth interval ending December 12, 2025 12

RELIEF REQUEST: Proposed Actions For ASME valves maintained with ANSI parts:

Repair will be performed in accordance with ASME Section XI using ASME Section III construction code requirements For ASME valves replaced with ANSI valves:

Repair will be performed in accordance with ASME Section XI using ANSI construction code requirements until the valves are replaced Future valve replacements will be performed in accordance with ASME Section XI using ASME Section III Construction Code valves and requirements 13

RELIEF REQUEST: Proposed Actions (continued)

For ASME Pumps with Non-ASME Motor Assemblies:

Repair will be performed in accordance with ASME Section XI using ASME Section III Construction Code requirements Replacements will be performed in accordance with ASME Section XI using ASME Section III Construction Code pump motor assemblies and requirements 14

RELIEF REQUEST: Proposed Actions (continued)

Demineralizer influent strainer (replaced with pipe and elbows):

Accept as is ASME Section III material was installed ASME Section IX welding installed it QC visual examinations of welds were performed NDE surface examinations were performed (no recordable indications) 15

TECHNICAL EVALUATION: Safety Reactor coolant pressure boundary isolation not affected Automatic system isolation function not affected Pipe break detection instrumentation not affected No new postulated break locations introduced Postulated high energy line breaks described in FSAR chapter 3.6 None of the piping in the reactor building where pipe breaks are postulated was replaced or repaired; i.e., it is still ASME III/3 Existing FSAR safety analysis for postulated pipe ruptures involving RWCU system outside of containment are not impacted 16

TECHNICAL EVALUATION: Quality ANSI B31.1 materials and components were subject to the Owners quality control program Receiving of materials and components, inspection, and assignment of unique identification to parts and materials used for repairs and replacements Installation of components used welding procedures qualified to ASME Section IX, welding filler material control, and final QC inspection of the welds made in conformance to the design requirements Parts installed can be traced back to material requests and specific catalogue identification number associated with the design requirements and ASME or ASTM standard 17

TECHNICAL EVALUATION: Valves For the ASME III/3 and ANSI B31.1 valves, the standard utilized is B16.5 (B16.34 for current Code years)

The two Codes provide the same dimensional guidance for critical configurations (e.g. valve ends)

The two Codes provide the same requirements for socket welds and butt welds Welding is performed using ASME Section IX requirements for both ANSI B31.1 and ASME III/3 18

TECHNICAL EVALUATION: Welds The ASME Section III Code of Record for the RWCU system is the 1971 Edition with Winter 1973 Addenda Replaced components used either butt welds or small bore socket welds For small bore socket welds, a visual inspection is required ANSI butt welds greater than 2 inches that required NDE surface exams received NDE in 2014 using magnetic particle (MT) examination and were satisfactory 19

TECHNICAL EVALUATION: Pumps The currently installed sealless water-cooled motor assemblies were designed to ASME III/3, but not constructed to ASME III/3 Replacement motor casing assemblies fabricated from ASME material and the fabrication methods used were controlled by applicable welding procedures for the materials of construction.

The NDE methods employed meet the intent of the ASME Code and the final hydrostatic test was conducted at the required pressure with an extended hold time using an ASME Section III pressure test procedure The currently installed pump cases are original OEM ASME III/3 parts, were not replaced, and remain in place 20

TECHNICAL EVALUATION: Operating Experience The replacement plug valves installed per ANSI B31.1 have performed very well Minor packing leaks and limit switch adjustments have been performed ANSI valves operated the first 10 years without any seat leakage issues Of the 31 ANSI valves installed in 1996 and 1997, two valves developed seat leakage in 2008, three in 2012 and two in 2014 21

TECHNICAL EVALUATION: Operating Experience Pump motor assemblies were replaced due to motor stator failures and not pressure boundary failures No pressure boundary failures of ANSI components have been experienced 22

CONCLUSION Relief is requested from the ASME Section XI code requirement of IWA-4221(b)(1) based upon 10 CFR 50.55a(z)(i)

A total of 41 RWCU system components currently do not meet requirements of ASME Section III, Class 3 Technical evaluation shows excellent operating history for ANSI components Affected components have demonstrated performance with an acceptable level of safety and quality and are suitable for extended in-plant operation 23

CLEANUP RECIRC PUMP 1A V-34 FIGURE 1. REACTOR WATER CLEANUP SYSTEM 830651.2LT FEB 2015 Color RWCU MO MO MO FI R609 MO V-100 MO V-101 V-102 MO REACTOR VESSEL MO V-106 TO REACTOR RECIRC PUMP A TO REACTOR RECIRC PUMP B ISOLATION SIGNAL RMS MO INBD ISOL.

VALVE A. C.

V-1 FE 35 RMS MO OUTBD ISOL.

VALVE D. C.

V-4 FT 36 V-5A V-5B PRIMARY CONTAINMENT V-769 V-768 V-12A V-13A V-13B V-12B CLEANUP RECIRC PUMP 1B FE 40 V-104 MO V-42 MO V-40 V-105 MO V-31 RO 1

FCV-33 BLOWDOWN FLOW CONTROL VALVE V-32 AO AO V-231A V-231B FCV-266A FCV-266B RT RT V-206B V-232B MO V-44 AO V-206A V-232A RX CLOSED COOLING WATER EDR 2A 2B NON-REGENERATIVE HEAT EXCHANGER 1A 1B 1C REGENERATIVE HEAT EXCHANGERS V-767 V-766 V-765 EDR TO MAIN CONDENSER DRAIN TO WASTE COLLECTOR OR SURGE TANK (RADWASTE)

K602 RETURN TO FEEDWATER FT FILTER DEMIN

' A '

FILTER DEMIN

' B '

41 EDR PUMP SUCTION SUBCOOLING LINE MO MO MO MO FE 11 FT 15 V-35 (DELTA FLOW ISOLATION)

FS 15 RWCU-V-4 ISOLATION SIGNAL FT 16 FS 16 RWCU-V-1 ISOLATION SIGNAL AO AO KEY:

PUMP MOTOR/MOTOR CASE REPLACED NON-ASME REPLACED WITH ANSI VALVE INTERNAL COMPONENTS REPLACED WITH NON-ASME SECTION III NDE PERFORMED EXTENT OF SYSTEM RECLASSIFICATION ASME III CLASS 3 (NON-SAFETY)

ASME III CLASS 2 (SAFETY RELATED) - NOT PART OF RECLASSIFICATION ASME III CLASS 1 (SAFETY RELATED)

ASME III CLASS 1 (SAFETY RELATED)

RADWASTE BUILDING 1150 PSIG 120° F 1200 PSIG 520° F AO

234 FIGURE 2. RWCU RADWASTE BUILDING (REPRESENTATIVE OF ONE DEMINERALIZER) 950155.27Color Feb 2015 RWCU FG AO 207 230 AIR FILTER FE AO 213 FROM NRHX (INFLUENT)

CLEANUP PHASE SEPARATOR BACKWASH AIR 233 (BACKWASH OUT) 208 206 AO AO AO AO 232 242 243 (BACKWASH) 241 FE FT AO 231 266 FCV (BACKWASH VENT) dPIS dPIS 245 244 (EFFLUENT)

(TRAP BACKWASH)

FROM CONDEN-SATE STRAINER 92 REMOVED AO 229 212 TUBE SHEET VENT 239 AO AO 214 238 211 AO 210 AO 235 HOLD PUMP P3 4

4 3

3 2

2 1

1 1/2 1/2 FROM PRECOAT TO PRECOAT TO PRECOAT TANK FROM OTHER DEMIN TO OTHER DEMIN TO RHX 248 247 246 KEY:

REPLACED WITH ANSI VALVE INTERNAL COMPONENTS REPLACED WITH NON-ASME SECTION III NDE PERFORMED

SUCTION INLET DIFFUSER THERMOWELL STATOR WINDINGS STATOR LAMINATIONS PUMP CASE DISCHARGE IMPELLER PURGE CONNECTION PUMP END BEARING L. P.

COOLING WATER MOTOR CAVITY HEAT EXCHANGER MOUNTING BRACKETS H. P.

COOLING WATER FILTER MOTOR COVER FILLER AND DRAIN CONNECTION 840183.02LT AUGUST 1995 RWCU ROTOR MOTOR CASE COVER END BEARING THRUST BEARING ASSEMBLY FIGURE 2A. RWCU PUMP/MOTOR CAVITY HEAT EXCHANGER