NRC-2009-0025, And Revision 51 to Emergency Plan and Emergency Plan Manual
| ML14342A147 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 02/27/2009 |
| From: | Jim Costedio Florida Power & Light Energy Point Beach |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML14342A206 | List: |
| References | |
| FOIA/PA-2014-0487, NRC-2009-0025 | |
| Download: ML14342A147 (16) | |
Text
0 FPL Energy Point Beach, LLC, 6590 Nuclear Road, Two Rivers, WI 54241 FPL Energy.
Point Beach Nuclear Plant February 27, 2009 NRC 2009-0025 10 CFR 50.54(q)
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Units 1 and 2 Dockets 50-266 and 50-301 License Nos. DPR-24 and DPR-27 Revision To Emergency Plan In accordance with 10 CFR 50.54(q), FPL Energy Point Beach, LLC, evaluated one procedure revision to the Point Beach Nuclear Plant (PBNP) Emergency Plan (EP). The evaluation concluded that the change did not result in a decrease of the effectiveness of the PBNP Emergency Plan.
Enclosed is a copy of the following procedure:
EP Appendix M, Matrix For Emergency Preparedness Equipment, Revision 2, issued January 29,' 2009.
Also enclosed is Revision 51 to the EP Index, issued January 29, 2009.
A copy of the complete PBNP EP Manual, containing the revised procedure, is being provided to the NRC Region III Incident Response Center on CD-ROM.
This letter contains no new commitments and no revisions to existing commitments.
Very truly yours, FPL Energy Point Beach, LLC Jiostedi~~
Regulatory Affairs Manager Enclosures (2) cc:
Incident Response Center, Region III (copy of PBNP EP Manual on CD-ROM) wqs-Resident Inspector, Point Beach Nuclear Plant, USNRC An FPL Group company
ENCLOSURE 1 FPL ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS I AND 2 EMERGENCY PLAN EP INDEX REVISION 51, ISSUED JANUARY 29, 2009 1 page follows
POJINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL JINDEX EP IN4DEX Revision 51 January 29, 2009 PERIODIC REVIEW!
CANCELED DATE PROCEDURE NUMBER REVISION EFFECTIVE NUMBER DATE PROCEDURE TITLE TABLE OF CONTENTS EP 1.0 EP 2.0 EP 3.0 EP 4.0 EP 5.0 EP 6.0 EP 7.0 EP 8.0 EP 9.0 Introduction..............................................
29 Emergency Plan Acronyms & Definitions............ 45 Summary of Emergency Plan...........................
26 Emergency Conditions..................................
43 Organizational Control Of Emergencies............... 52 Emergency Measures....................................
50 Emergency Facilities And Equipment................. 52 Maintaining Emergency Preparedness................. 49 Recovery.................................................
39 09/28/07 09/28/07 09/28/07 09/28/07 09/28/07 09/28/07 0 1/16/08 09/28/07 09/28/07 01/15/09 01/15/09 01/15/09 01/15/09 01/15/09 01/15/09 01/15/09 01/15/09 01/15/09 APPENDICES APPENDIX A APPENDIX B APPENDIX C APPENDIX D APPENDIX E APPENDIX F APPENDIX G APPENDIX H APPENDIX I APPENDIX J APPENDIX K APPENDIX L, IAPPENDIX M Emergency Response Organization Personnel Function And Responsibility.......................
27 Emergency Classification............................
23 Maps....................................................
16 Letters Of Agreement 28 State Of Wisconsin Emergency Operations Plan....7 Manitowoc County Emergency Operations Plan.... 10 Kewaunee County Emergency Operations Plan....10 Typical Equipment Lists..................................
List Of EPIP Categories And Cross-References To The Emergency Plan.............................
17 Evacuation Time Estimates For The Area Surrounding EPLE Point Beach.................... 14 NUREG-0654 Cross Reference Matrix............... 4 Meteorological Monitoring System Design, Testing And Calibration.............................
2 Matrix For Emergency Preparedness Equipment....2 05/12/08 01/20/06 09/28/07 0 1/15/09 09/28/07 09/28/07 09/28/07 CANCELED 05/12/08 01/15/09ý 01/15/09 01/15/09 01/15/09 01/15/09 01/15/09 12/15/05 11/29/06 01/15/09 09/28/07 09/28/07 09/23/05 01/29/09 0 1/15/09 01/15/09 0 1/15/09 01/29/09 CROSS-REFERENCE INDEX EP CR JINDEX Emergency Plan Cross-Reference Index............. 15 (Q - Quarantine)
(T - Temporary Change)
Page 1 of 1 09/28/07 01/15/09
ENCLOSURE 2 FPL ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS I AND 2 EMERGENCY PLAN EP APPENDIX M REVISION 2, ISSUED JANUARY 29, 2009 12 pages follow
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory /
Location Equipment Name Licensing Basis Required EP Function Description 1(2)B03/1 (2)B04 NPC-28427, 9/1/83 Control Room 1 (2)A05/1 (2)A06 letter referencing Reg 480V and 4160V power to safeguards C02 Voltage Indication Guide 1.97, Rev 2 equipment.
Supply DC power directly to operate NPC-28427, 9/1/83 selected emergency turbine generator Control Room 1 D01 -1 D04 letter referencing Reg auxiliaries and safeguard motor and C20 Battery Busses Guide 1.97, Rev 2 solenoid operated valves.
Control Room 1 (2)L-3586A DBD-T-41 Module A Indication of lake pumpbay level and C03 Lake Pumpbay Level FSAR Section 10.1 potential flooding.
Control Room 1 (2)L-3586B DBD-T-41 Module A Indication of lake forebay level and C03 Lake Forebay Level FSAR Section 10.1 potential flooding.
1 (2)LI-426/-427/-428 LI-433A NPC-28427, 9/1/83 Control Room Pressurizer Level letter referencing Reg Monitors pressurizer level with LI-433 C04 Indication Guide 1.97, Rev 2 used during low temperature operations.
1 (2)LI-447/LI-447A Reactor Vessel Level Control Room Indicator (Low Range C04 and High Range)
FSAR Section 4.0 Indication of reactor vessel level.
1(2)LI-461/-462/-463 N PC-28427, 9/1/83 Control Room Narrow Range S/G letter referencing Reg C03 Level Guide 1.97, Rev 2 Monitors levels in each steam generator.
1 (2)LI-471/-472/-473 N PC-28427, 9/1/83 Control Room Narrow Range S/G letter referencing Reg C03 Level Guide 1.97, Rev 2 Monitors levels in each steam generator.
Control Room 1 (2)LI-4107 C01 Containment Sump A Reg Guide 1.97, Rev 2 Indication of RCS leakage.
1(2) PI-429/-430/-431/-
449 Control Room Pressurizer Pressure C04 Indication Reg Guide 1.97, Rev 2 Monitors pressurizer pressure.
1 (2)PI-945/-947/-949 Containment Pressure NPC-28427, 9/1/83 Control Room Narrow Range letter referencing Reg Provides alarm and safety injection C01 Indication Guide 1.97, Rev 2 actuation logic.
1 (2)PI-946/-948/-950 N PC-28427, 9/1/83 Control Room Containment Pressure letter referencing Reg C01 Wide Range Indication Guide 1.97, Rev 2 Provides alarm and steam line isolation.
1 (2)PR-420 Wide Range Pressure Reactor Coolant Hot Control Room Leg Pressure Monitors pressure on reactor coolant hot C04 Recorder Reg Guide 1.97, Rev 2 leg.
Page 1 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory I Location Equipment Name Licensing Basis Required EP Function Description 66' 1(2)RE-102 NPC-28427, 9/1/83 Containment Containment U-2 Low letter referencing Reg Hatch Range U-1 Guide 1.97, Rev 2 Indication of dose rate within containment.
1 (2)RE-104 Charging NPC-28427, 9/1/83 8' PAB CCP Pump Room Low letter referencing Reg Indication of dose rate by charging pump Area Range Guide 1.97, Rev 2 cubicles.
26'/PAB NPC-28427, 9/1/83 U-1 (2) Sample 1(2)RE-106 Sample letter referencing Reg Indication of dose rate inside sample Room Room Low Range Guide 1.97, Rev 2 room.
NPC-28427, 9/1/83 46' NE Qtr 1(2)RE-107 Seal letter referencing Reg Containment Table Guide 1.97, Rev 2 Indication of dose rate near seal table.
NPC-28427, 9/1/83 26' PAB 1 (2)RE-109 Failed letter referencing Reg Indication of failed fuel by monitoring the Sample Room Fuel Guide 1.97, Rev 2 primary coolant sample line.
1(2)RE-134 Charging NPC-28427, 9/1/83 Indication of general area dose rates in 8' PAB CCP Pump Room High letter referencing Reg the event low-range monitor pegs Area Range Guide 1.97, Rev 2 off-scale high.
1(2)RE-136 Primary NPC-28427, 9/1/83 Indication of general area dose rates in 26' PAB Sample Room High letter referencing Reg the event low-range monitor pegs Sample Room Range Guide 1.97, Rev 2 off-scale high.
1(2)RE-211 Indication of particulate activity inside Containment Air containment fagade or purge exhaust 52' Fagade Particulate Reg Guide 1.97, Rev 2 stack.
1 (2)RE-21 1 B Containment Indication of background activity for both 52' Fagade
Background
Reg Guide 1.97, Rev 2 1 (2)RE-211 and 1 (2)RE-212.
1(2)RE-212 Indication of containment noble gas Containment Noble activity. Isolate containment ventilation 52' Facade Gas Reg Guide 1.97, Rev 2 upon high activity.
VPNPD-85-537, 1(2)RE-215 11/27/85 letter 44' TB by Condenser Air Ejector referencing Indication of steam generator MSRs Noble Gas Reg Guide 1.97, Rev 2 primary-to-secondary leak.
1(2)RE-216 Containment Fan 26' PAB by Coolers SW Return Indication of potential contamination of C59 Panel Liquid Process Reg Guide 1.97, Rev 2 cooling water.
26' PAB by 1(2)RE-216B T-10A Monitor Containment Fan Provides background data for the Tank Coolers Background Reg Guide 1.97, Rev 2 1(2)RE-216 liquid process monitor.
Page 2 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory I Location Equipment Name Licensing Basis Required EP Function Description 1(2)RE-217 8' PAB CCW Component Cooling Indication of component cooling water Pump Area Water Liquid Process Reg Guide 1.97, Rev 2 contamination.
1 (2)RE-219 Steam 26' PAB Generator Blowdown Indication of steam generator blowdown Sample Room Sample Line Monitor Reg Guide 1.97, Rev 2 activity.
1(2)RE-219B Steam 26' PAB Generator Blowdown Background activity level for 1(2)RE-219 Sample Room
Background
Reg Guide 1.97, Rev 2 liquid process monitor.
1 (2)RE-222 Steam Generator Blowdown Tank Outlet Liquid Indication of activity level in blowdown 26' Faade Process Reg Guide 1.97, Rev 2 tank.
8' Vital 1 (2)RE-229 Service Switchgear Water Discharge Monitors activity of service water Equip Area Process Reg Guide 1.97, Rev 2 discharge.
8' Vital 1 (2)RE-229B Service Switchgear Water Discharge Indication of background activity level for Equip Area
Background
Reg Guide 1.97, Rev 2 the 1(2)RE-229 monitor.
NPC-28427, 9/1/83 and 1(2)RE-231 -Line A VPNPD-85-282, 85' Fagade 1 (2)RE-232-Line B 8/30/85 letters Steam Safety Steam Line referencing Valves Atmospheric Release Reg Guide 1.97, Rev 2 Monitors activity of steam released.
1(2)RE-305 SPING Unit Containment NPC-28427, 9/1/83 46' Rod Drive Purge Exhaust Low letter referencing Reg Monitors noble gas activity in unit Rooms Range Gas Guide 1.97, Rev 2 containment purge exhaust.
1 (2)RE-306 SPING N PC-28427, 9/1/83 46' Rod Drive Unit Containment letter referencing Reg Monitors noble gas activity in unit Rooms Purge Exhaust Area Guide 1.97, Rev 2 containment purge exhaust.
1(2)RE-307 SPING Unit Containment NPC-28427, 9/1/83 46' Rod Drive Purge Exhaust Mid letter referencing Reg Monitors noble gas activity in unit Rooms Range Gas Guide 1.97, Rev 2 containment purge exhaust.
1 (2)RE-309 SPING Unit Containment N PC-28427, 9/1/83 46' Rod Drive Purge Exhaust High letter referencing Reg Monitors noble gas activity in unit Rooms Range Gas Guide 1.97, Rev 2 containment purge exhaust.
60' CB 1(2)RM-126 NPC-28427, 9/1/83 Indication of failed fuel by monitoring Computer Containment High letter referencing Reg general area dose rates under accident Room Range Monitor Guide 1.97, Rev 2 conditions.
Page 3 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory I Location Equipment Name Licensing Basis Required EP Function Description 60' CB 1(2)RM-127 NPC-28427, 9/1/83 Indication of failed fuel by monitoring Computer Containment High letter referencing Reg general area dose rates under accident Room Range Monitor Guide 1.97, Rev 2 conditions.
60' CB 1(2)RM-128 NPC-28427, 9/1/83 Indication of failed fuel by monitoring Computer Containment High letter referencing Reg general area dose rates under accident Room Range Monitor Guide 1.97, Rev 2 conditions.
1(2)TR-450A-D 1 (2)TR-451 A-D Provides signals to wide range recorders Control Room Hot Leg / Cold Leg and C20 ASIP to monitor temperature C04 Temperatures Reg Guide 1.97, Rev 2 during heatup and cooldown.
Control Room 1(2)X04 Auxiliary Provides power to auxiliary loads of a C02 Transformer FSAR Section 8 shutdown unit.
Indication of overall plant alarming Control Room Annunciator system EP Appendix B EALs conditions.
ASIP Panel (Fireworks NUREG 0654 H.5.d Indication of fire using smoke and heat Control Room Computer)
Reg Guide 1.97 Rev 2 activated detectors.
Control Room C900 Indication of fire using smoke and heat Col Fire Protection Panel NUREG 0654 H.5.d activated detectors.
CR/TSC/EOF/
Supports communications onsite and AEOF/JPIC Copier NUREG 0696 (4.6) offsite.
Core Exit NPC-28427, 9/1/83 Thermocouples letter referencing Reg Control Room (CETs)
Guide 1.97, Rev 2 Provides temperature of the reactor core.
D-400 to D-420 Fire Protection Panels Indication of fire using smoke and heat Control Room Satellite NUREG 0654 H.5.d activated detectors.
10CFR50.72(a)(2) 1 0CFR50 App E(E9) 44' TB1 NUREG 0696, 4.6 Telephone D-48 / D-59 10CFR50 App E, Equipment Telecoms Battery NUREG 0737 Backup power sources for onsite and Room/SBCC Backups Supp. 1, Section 8 offsite communications systems.
Decontamination OSC/OSRPF facilities 1 0CFR50 App E(E3)
Contamination event response.
NUREG 0696 (4.5),
CR/TSC/EOF/
Dose Assessment 10CFR50 App E(E.2),
Perform dose assessment calculations for AEOF Hardware/Software 10CFR50.47(b)(9) offsite impact.
Reg Guide 1.196, GDC 19, GL 2003-01 NUREG 0696 (pg 16)
CR/TSC/OSC/
Emergency Ventilation NUREG 0737 II.B.2, Ensure habitability to emergency EOF/OSRPF System GL-91-014 response facilities.
Page 4 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory!
Location Equipment Name Licensing Basis Required EP Function Description 60' CB NUREG 0696 (6.2)
Computer GL 89-015, GL 93-001, Room/
ERDS SECY 91-165, CRiTSC Hardware/Software 10CFR50 App E VI Provides plant system data to NRC.
Control Room ERO Dialogic System NUREG 0654 B ERO activation using offsite system.
Control Room ERO Pagers NUREG 0654 B ERO activation using offsite system.
CR/TSC/EOF/
Supports communications onsite and AEOF/JPIC Fax machines NUREG 0696 (4.6) offsite.
NPC-30022, 7/11/86 letter referencing Reg Control Room Fl-1 28 and Fl-1 34 Guide 1.97 C04 Charging/Letdown Rev 2 Indication of the flow rate into the RCS.
FI-4036 / FI-4037 Control Room Auxiliary Feedwater to Monitors auxiliary feedwater flow to each C03 S/G Reg Guide 1.97, Rev 2 steam generator.
Control Room FI-464/FI-465 C03 Steam Flow Indication Reg Guide 1.97, Rev 2 Measure steam flow on "A" steam line.
FI-466/FI-467 Control Room Feedwater Flow Provide flow information for the feedwater C03 Indication Reg Guide 1.97, Rev 2 control system.
Control Room FI-474/FI-475 C03 Steam Flow Indication Reg Guide 1.97, Rev 2 Measures steam flow on "B" steam line.
FI-476/FI-477 Control Room Feedwater Flow C03 Indication Reg Guide 1.97, Rev 2 Indication of feedwater flow.
Direct voice intercommunications and/or FM Radio Base NUREG 0696, 3.3 reliable direct radio communications may CR/TSC/OSC/
Console and Site NUREG 0696 4.6 be used to supplement telephone EOF/OSRPF reentry FM radios 10CFR50 App E(E9) communication links.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 10CFR50 App E (E)
NUREG 0654 App 2 NPC-28427, 9/1/83 letter referencing Reg G-501 Guide 1.97, Rev 2 Alternate or backup power sources to G05 Building Emergency Power FSAR Section 8 maintain continuity of TSC functions.
CR/TSC Gai-tronics NUREG 0696 Backup communication to plant.
Page 5 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory I Location Equipment Name Licensing Basis Required EP Function Description NUREG 0696 4.6, 4.7 CR/TSC/OSC/
NUREG 0654 App 2, Data display and printout devices to EOF/AEOF/
LAN/WAN &
Reg Guide 1.97, Rev 2 maintain continuity of emergency JPIC equipment Reg Guide 1.23 response facility functions.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 1 OCFR50 App E (E)
Meteorological -
NUREG 0654 App 2, HWY Q &
Inland Tower N PC-28427, 9/1/83 Twin Bridge 10 meter wind letter referencing Reg Road direction Guide 1.97, Rev 2 Monitors wind direction at El. 10 meters.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, Meteorological -
1 OCFR50 App E (E)
Inland Tower NUREG 0654 App 2, HWY Q &
10 meter wind NPC-28427, 9/1/83 Twin Bridge direction Standard letter referencing Reg Monitors standard deviation on wind Road Deviation Guide 1.97, Rev 2 direction at El. 10 meters.
NUREG 0696 4.8, 1 OCFR50.47(b)(9),
Reg Guide 1.23, 1 OCFR50 App E (E)
NUREG 0654 App 2, HWY Q &
Meteorological -
NPC-28427, 9/1/83 Twin Bridge Inland Tower letter referencing Reg Road 10 meter wind speed Guide 1.97, Rev 2 Monitors wind speed at El. 10 meters.
NUREG 0696 4.8, 1 OCFR50.47(b)(9),
Reg Guide 1.23, 10CFR50 App E (E)
NUREG 0654 App 2, HWY Q &
Meteorological -
NPC-28427, 9/1/83 Twin Bridge Inland Tower letter referencing Reg Road 4 meter Temperature Guide 1.97, Rev 2 Monitors temperature.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 1 OCFR50 App E (E)
Meteorological -
NUREG 0654 App 2, Primary Tower NPC-28427, 9/1/83 10 meter delta T letter referencing Reg Monitors temperature for AT at El. 10 PBNP South Reference Guide 1.97, Rev 2 meters.
Page 6 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EQUIPMENT EP Appendix M Revision 2 January 29, 2009 Equipment or Indication Regulatory /
Location Equipment Name Licensing Basis Required EP Function Description NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 10CFR50 App E (E)
Meteorological -
NUREG 0654 App 2, Primary Tower NPC-28427, 9/1/83 10 meter wind letter referencing Reg PBNP South direction Guide 1.97, Rev 2 Monitors wind direction at El. 10 meters.
NUREG 0696 4.8, 1 OCFR50.47(b)(9),
Reg Guide 1.23, 1 OCFR50 App E (E)
NUREG 0654 App 2, Meteorological -
NPC-28427, 9/1/83 Primary Tower letter referencing Reg PBNP South 10 meter wind speed Guide 1.97, Rev 2 Monitorswind speed at El. 10 meters.
NUREG 0696 4.8, 1 OCFR50.47(b)(9),
Reg Guide 1.23, Meteorological -
10CFR50 App E (E)
Primary Tower NUREG 0654 App 2, 10 meters wind NPC-28427, 9/1/83 Monitors wind direction. Monitors direction Standard letter referencing Reg standard deviation of wind direction at El.
PBNP South Deviation Guide 1.97, Rev 2 10 meters.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 1 OCFR50 App E (E)
NUREG 0654 App 2, Meteorological -
NPC-28427, 9/1/83 Primary Tower letter referencing Reg Monitors temperature for AT at El. 45 PBNP South 10 to 45 meter delta T Guide 1.97, Rev 2 meters.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 10CFR50 App E (E)
Meteorological -
NUREG 0654 App 2, Primary Tower NPC-28427, 9/1/83 45 meter wind letter referencing Reg PBNP South direction Guide 1.97, Rev 2 Monitors wind direction at El. 45 meters.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 10CFR50 App E (E)
NUREG 0654 App 2, Meteorological -
NPC-28427, 9/1/83 Primary Tower letter referencing Reg PBNP South 45 meter wind speed Guide 1.97, Rev 2 Monitors wind speed at El. 45 meters.
Page 7 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EQUIPMENT EP Appendix M Revision 2 January 29, 2009 Equipment or Indication Regulatory /
Location Equipment Name Licensing Basis Required EP Function Description NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 1 OCFR50 App E (E)
Meteorological -
NUREG 0654 App 2, Backup Tower NPC-28427, 9/1/83 10 meter wind letter referencing Reg PBNP North direction Guide 1.97, Rev 2 Monitors wind direction at El. 10 meters.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, 10CFR50 App E (E)
NUREG 0654 App 2, Meteorological -
N PC-28427, 9/1/83 Backup Tower letter referencing Reg PBNP North 10 meter wind speed Guide 1.97, Rev 2 Monitors wind speed at El. 10 meters.
NUREG 0696 4.8, 10CFR50.47(b)(9),
Reg Guide 1.23, Meteorological -
10CFR50 App E (E)
Backup Tower NUREG 0654 App 2, 10 meters wind NPC-28427, 9/1/83 direction Standard letter referencing Reg Monitors standard deviation of wind PBNP North Deviation Guide 1.97, Rev 2 direction at El. 10 meters.
10CFR50.72 (a)(1)
NRC Federal NUREG 0696 4.6 Communications to the NRC Operations Telephone System NUREG 0654 (F)
Center from the site emergency response CR/TSC/EOF (FTS) Circuit - ENS 10CFR50 App E(E9) facilities.
NRC Federal NUREG 0696 4.6 Communications to the NRC Operations TSC/EOF/
Telephone System NUREG 0654 (F)
Center from the site emergency response AEOF (FTS) Circuit - HPN 10CFR50 App E(E9) facilities.
NUREG 0696, NRC Federal GL 91-014, Telephone System SECY-91-303, Communications to the NRC Operations TSC/EOF/
(FTS) Circuits -
SECY091-149, Center from the site emergency response AEOF Counterparts 10CFR50 App E(E9) facilities.
Monitors the status of the reactor power level in all modes of plant operation, as Nuclear NPC-28427, 9/1/83 well as provide overpower trip protection Control Room Instrumentation letter referencing Reg for the reactor in the startup and power C04 System (NIS)
Guide 1.97, Rev 2 operation modes.
Post-Accident Sample reactor coolant system or Sampling Systems NUREG 0654 atmosphere due to fuel failure or loss of PAB (PASS)
NUREG 0737 ll.B.3 reactor coolant system integrity.
Page 8 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory I Location Equipment Name Licensing Basis Required EP Function Description NUREG 0696 4.7, 4.8 NUREG 0654 App 2, Reg Guide 1.97 Rev 2, Reg Guide 1.23 CR/TSC/EOF/
Suitable isolation lAW AEOF PPCS GDC 24 Data source for plant assessment.
N PC-28427, 9/1/83 letter referencing Reg Shifts Control Room ventilation to 100%
Control Room RE-101 Control Room Guide 1.97, Rev 2 recirculation.
NPC-28427, 9/1/83 SSB Chem letter referencing Reg Indication of dose rates in chemistry lab Lab RE-103 Chem Lab Guide 1.97, Rev 2 and associated hallways.
NPC-28427, 9/1/83 66' PAB SFP RE-1 05 Spent Fuel letter referencing Reg Indication of dose rates in the vicinity of Area Pool Low Range Guide 1.97, Rev 2 the spent fuel pool.
26' PAB NPC-28427, 9/1/83 Drumming RE-108 Drumming letter referencing Reg Indication of dose rates within the Area Station Guide 1.97, Rev 2 drumming station.
NPC-28427, 9/1/83 8' PAB Sl RE-1 10 Sl Pump Low letter referencing Reg Indication of dose rate in general area of Pump Area Range Guide 1.97, Rev 2 safety injection pumps.
NPC-28427, 9/1/83 26' PAB C59 letter referencing Reg Provides general area dose rate near C59 Area RE-111 C59 Panel Guide 1.97, Rev 2 panel.
NPC-28427, 9/1/83 letter referencing Reg Provides general area dose rate on El 8' 8' PAB Central RE-1 12 PAB Guide 1.97, Rev 2 of primary auxiliary building.
NPC-28427, 9/1/83 Provides indication of dose rate in RE-113 EI.-19' Aux letter referencing Reg auxiliary building sump and general area
-19' PAB Bldg Guide 1.97, Rev 2 of El. -19'.
NPC-28427, 9/1/83 RE-1 14 El. 26' Aux letter referencing Reg 26' PAB West Bldg Guide 1.97, Rev 2 Indication of dose rates in cubicle.
NPC-28427, 9/1/83 RE-1 16 Letdown letter referencing Reg Indication of general area dose rate in 26' PAB Valve Gallery Guide 1.97, Rev 2 letdown valve gallery.
N PC-28427, 9/1/83 Indication of general area dose rates in RE-135 Spent Fuel letter referencing Reg the event low-range monitor pegs 66' PAB SFP Pool High Range Guide 1.97, Rev 2 off-scale high.
NPC-28427, 9/1/83 Indication of general area dose rates in 8' PAB Sl RE-140 SI Pump letter referencing Reg the event low-range monitor pegs Pump Area Room High Range Guide 1.97, Rev 2 off-scale high.
Page 9 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory I Location Equipment Name Licensing Basis Required EP Function Description RE-214 Aux. Bldg.
Indication of gaseous release from spent 80' Ul Fagade Vent Stack Noble Gas Reg Guide 1.97, Rev 2 fuel pool area and the drumming station.
8' PAB East RE-218 Waste Waste Cond Disposal System Provides waste condensate activity being Tank Liquid Process Reg Guide 1.97, Rev 2 discharged.
8' PAB East RE-218B Waste Waste Cond Disposal System Provides background activity level for Tank
Background
Reg Guide 1.97, Rev 2 RE-218 liquid process monitor.
RE-220 Spent Fuel Pool Heat Exchanger Provides indication of service water 46' PAB SFP Service Water Liquid contamination from a spent fuel pool Area Process Reg Guide 1.97, Rev 2 exchanger tube leak.
RE-220B Spent Fuel Pool Heat Exchanger 46' PAB SFP Service Water Provides background activity level for Area
Background
Reg Guide 1.97, Rev 2 RE-220 liquid process monitor.
50' PAB RE-221 Drumming Drumming Area Vent Stack Noble Indication of noble gas activity released Area Roof Gas Reg Guide 1.97, Rev 2 from spent fuel pool and drumming area.
RE-223 Waste 46' PAB East Distillate Discharge Monitors activity of waste distillate during CCW HX Liquid Process Reg Guide 1.97, Rev 2 discharge.
RE-223B Waste 46' PAB East Distillate Discharge Provides background activity level for CCW HX Area
Background
Reg Guide 1.97, Rev 2 RE-223 liquid process monitor.
RE-224 Gas Stripper Indication of gaseous release from 85' U2 Facade Vent Stack Noble Gas Reg Guide 1.97, Rev 2 letdown gas stripper building.
VPNPD-85-537, RE-225 Combined Air 11/27/85 letter Ejector Low-Range referencing Reg Guide Indication of primary-to-secondary leak in 44' TB Ul Noble Gas 1.97, Rev 2 steam generators.
Indication of noble gas activity in RE-226 Combined Air NPC-28427, 9/1/83 combined air ejector discharge in the Ejector High-Range letter referencing Reg event RE-225 monitor is pegged off-scale 44' TB U1 Noble Gas Guide 1.97, Rev 2 high.
RE-230 Waste Water Monitors activity level in waste water 8' TB WT U2 Effluent Reg Guide 1.97, Rev 2 effluent.
RE-230B Waste Water Provides background activity level for 8' TB U2 Effluent Background Reg Guide 1.97, Rev 2 RE-230 liquid monitor.
74' CR/Comp RE-234 Control Room Roof Room Iodine Reg Guide 1.97, Rev 2 Monitors iodine activity in Control Room.
Page 10 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL MATRIX FOR EMERGENCY PREPAREDNESS EP Appendix M Revision 2 January 29, 2009 EQUIPMENT Equipment or Indication Regulatory /
Location Equipment Name Licensing Basis Required EP Function Description 74' CR/Comp RE-234B Control Provides background activity level for Room Roof Room Background Reg Guide 1.97, Rev 2 RE-234 iodine monitor.
74' CR/Comp RE-235 Control Room Monitors noble gas activity in Control Room Roof Noble Gas Reg Guide 1.97, Rev 2 Room.
Monitors iodine and noble gas activity.
RE-237, 238, 239, 240 Indication of general area dose rates in 18.5 TSC NW Monitors NUREG 0696 (2.6)
TSC.
Monitors iodine and noble gas activity.
RE-241, 242, 243 Indication of general area dose rates in SBCC Monitors NUREG 0696 (4.5)
EOF.
RE-315 SPING NPC-28427, 9/1/83 46' UL1 Rod Auxiliary Building Vent letter referencing Reg Monitors noble gas activity in the auxiliary Drive Room Low Range Gas Guide 1.97, Rev 2 building vent.
RE-316 SPING NPC-28427, 9/1/83 46' Ul Rod Auxiliary Building letter referencing Reg Monitors noble gas activity in the auxiliary Drive Room Exhaust Area Guide 1.97, Rev 2 building.
RE-317 SPING NPC-28427, 9/1/83 46' U1 Rod Auxiliary Building Vent letter referencing Reg Monitors noble gas activity in the auxiliary Drive Room Mid Range Gas Guide 1.97, Rev 2 building vent.
RE-319 SPING NPC-28427, 9/1/83 46' Ul Rod Auxiliary Building Vent letter referencing Reg Monitors noble gas activity in the auxiliary Drive Room High Range Gas Guide 1.97, Rev 2 building vent.
50' PAB NPC-28427, 9/1/83 Drumming RE-321 Drumming letter referencing Reg Monitors beta particulate activity in the Area Roof Area Exhaust Guide 1.97, Rev 2 auxiliary building vent.
50' PAB RE-325 SPING NPC-28427, 9/1/83 Drumming Drumming Area Vent letter referencing Reg Monitors noble gas activity in the auxiliary Area Roof Low Range Gas Guide 1.97, Rev 2 building vent.
50' PAB RE-326 SPING NPC-28427, 9/1/83 Drumming Drumming Area letter referencing Reg Monitors noble gas activity in the auxiliary Area Roof Exhaust Area Guide 1.97, Rev 2 building vent.
50' PAB RE-327 SPING NPC-28427, 9/1/83 Drumming Drumming Area Vent letter referencing Reg Monitors noble gas activity in the auxiliary Area Roof Mid Range Gas Guide 1.97, Rev 2 building vent.
Control Room C04/CO1 Reactor Trip C04/C02 Pushbuttons EP Appendix B EALs Manual shutdown of reactor.
Removes total decay heat load generated Control Room by the respective unit reactor plant during C01/C03 RHR/Safety Trains FSAR Chapter 6, 9 a cooldown following a shutdown.
Page 11 of 12
POINT BEACH NUCLEAR PLANT EMERGENCY PLAN MANUAL EP Appendix M Revision 2 January 29, 2009 MATRIX FOR EMERGENCY PREPAREDNESS EQUIPMENT Equipment or Indication Regulatory /
Location Equipment Name Licensing Basis Required EP Function Description Base Commitment - 1 strong motion accelerograph.
13.8 kV SEI-6210 NUREG 0654 H.5.a Switchgear Seismic Monitor FSAR 1.3, GDC Detects seismic activity.
Base Commitment - 1 strong motion accelerograph.
6.5' Ul SEI-6211 NUREG 0654 H.5.a Fagade Seismic Monitor FSAR 1.3, GDC Detects seismic activity.
Base Commitment - 1 strong motion 26' PAB accelerograph.
Drumming SEI-6212 NUREG 0654 H.5.a Area Seismic Monitor FSAR 1.3, GDC Detects seismic activity.
Base Commitment - 1 strong motion 8' Vital accelerograph.
Switchgear SEI-6213 NUREG 0654 H.5.a Detects seismic activity.
Equip Room Seismic Monitor FSAR 1.3, GDC Sirens Offsite PBNP P-001 to P-014 NUREG 0654 EPZ K-001 to K-008 FEMA REP 10 Prompt offsite notification system.
CR/ITSC/EOF/
State/County 10CFR50 App E(E9)
Communications with State and local AEOF Notification System 10CFR50.47 (b)(6) operations centers.
8'PAB T-19 Detects high volumes of potentially C59 Alarm Waste holdup Tank EP Appendix B EALs radioactive and radioactive liquids.
Telecom System Communicate to power system control Inter-Plant Trouble center if rapid power reduction is being Control Room Alarm EP 7.0 done.
1 0CFR50.72(a)(2) 10CFR50 App E(E9)
NUREG 0696, 3.3, 4.6 CR/TSC/OSC/
1 OCFR50 App E.9.b EOF/AEOF/
NUREG 0737 One onsite and one offsite JPIC Telecom Systems Supp. 1, Section 8 communications system (see D-48/D-59).
Page 12 of 12