GO2-14-152, Erratum for Relief Requests for the Fourth Ten-Year Interval Inservice Testing Program

From kanterella
(Redirected from ML14310A665)
Jump to navigation Jump to search

Erratum for Relief Requests for the Fourth Ten-Year Interval Inservice Testing Program
ML14310A665
Person / Time
Site: Columbia 
Issue date: 10/23/2014
From: Gregoire D
Energy Northwest
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GO2-14-152
Download: ML14310A665 (3)


Text

ENERGY NORTHWEST October 23, 2014 G02-14-152 Donald W. Gregoire P.O. Box 968, Mail Drop PE20 Richland, WA 99352-0968 Ph. 509-377-8616 F. 509-377-4674 dwgregoire@energy-northwest.com 10 CFR 50.55a U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001

Subject:

COLUMBIA GENERATING STATION, DOCKET NO. 50-397 ERRATUM FOR RELIEF REQUESTS FOR THE COLUMBIA GENERATING STATION FOURTH TEN-YEAR INTERVAL INSERVICE TESTING PROGRAM

Reference:

Letter, G02-14-049, dated April 2, 2014, A. L. Javorik (Energy Northwest) to NRC, "Relief Requests for the Columbia Generating Station Fourth Ten-Year Interval Inservice Testing Program"

Dear Sir or Madam:

Please replace Page 16 of 40 of Attachment 2 of the referenced letter with the enclosed page for relief reqyest RP03. A subsequent review revealed a confusing statement regarding valve posit.ion. indication. This statement has been removed since it was not material to the argument.:..,..,

There are no new or revised commitments with this letter. If you should have any questions regarding,this submittal, please Contact Ms. L. L. Williams, Licensing Supervisor, at 509-377-8148.

Executed on /O0/Z3 (/"/

D. W. Gregoire.

Manager, Regulatr Affairs

Enclosure:

A sa 4

cc:

NRC Region VAdministrator NRCNRR Project Manager NRC.Sr., Resident Jlnspectpr. 98.C..........

.MAJones-.BPN,1 399..

-,-:-.*i.,

j t

4-7

ERRATUM FOR RELIEF REQUESTS FOR THE COLUMBIA GENERATING STATION FOURTH TEN-YEAR INTERVAL INSERVICE TESTING PROGRAM Enclosure Relief Request RP03 Replacement Page

IST Program Plan Columbia Generating Station Page 16 of 40 4th 10-Year Interval (Relief Requests Only)

Relief Request - RP03 (Contd.)

Impracticality of Compliance The establishment of specific reference values is impractical for these pumps.

Burden Caused by Compliance Reference values are defined as one or more fixed sets of values of quantities as measured or observed when the equipment is known to be operating acceptably. All subsequent test results are to be compared to these reference values. Based on operating experience, flow rate (independent variable during inservice testing) for these pumps cannot be readily duplicated with the existing flow control systems. Flow control for these systems can only be accomplished through the operation of relatively large motor operated globe valves as throttling valves. The operator must repeatedly jog the motor operator to try to make even minor adjustments in flow rate. These efforts, to exactly duplicate the reference value, would require excessive valve manipulation which could ultimately result in damage to valves or motor operators.

Proposed Alternative and Basis for Use As discussed above, it is impractical to return to a specific value of flow rate, or differential pressure for testing of these pumps. As stated in NUREG-1482, Rev 2 Section 5.2, some system designs do not allow for testing at a single reference point or a set of reference points. In such cases, it may be necessary to plot pump curves to use as the basis for variable reference points. Code Case OMN-16,"Use of a Pump Curves for Testing," is included in draft Revision 1 of RG 1.192,"Operations and Maintenance Code Case Acceptability, ASME OM Code."

Since the independent reference variable (flow rate) for these pumps is impractical to adjust to a fixed reference value and requires excessive valve manipulation, the maximum variance shall be limited to

+/- 2% of the reference value. Thus, flow rate shall be adjusted to be within +/- 2% of the reference flow rate and the corresponding differential pressure shall be measured and compared to the reference differential pressure value determined from the pump reference curve established for this narrow range of flow rate. Slope of the pump reference curve is not flat even over this narrow range of flow rate. Assuming the flow rate to be fixed over this narrow range can result in additional error in calculating the deviation between the measured and reference differential pressure and at times this deviation can be non-conservative.

Since the dependent variable (differential pressure) can be assumed to vary linearly with flow rate in this narrow range, establishing multiple reference points in this narrow range is similar to establishing a reference pump curve representing multiple reference points. This assumption of linearity between differential pressure and flow rate is supported by the manufacturer pump curves in the stable design flow rate region.