NRR-PMDAPEm Resource From: Lyon, Fred Sent: Tuesday, August 05, 2014 10:57 AM To: Van Der Kamp, David Cc: George, Andrea

Subject:

Acceptance Review (TAC No. MF4429)

By letter dated July 15, 2014, NPPD submitted relief request RI-08 regarding inspection of RV nozzle-to-vessel shell welds for CNS for the 4th ISI Program Interval.

The purpose of this letter is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of the relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed your application and concluded that it provides technical information in sufficient detail to enable the staff to proceed with its detailed technical review and make an independent assessment regarding the acceptability of the proposed relief request in terms of regulatory requirements and the protection of public health and safety and the environment. If additional information is needed for the staff to complete its technical review, you will be advised by separate correspondence.

1

Hearing Identifier: NRR_PMDA Email Number: 1474 Mail Envelope Properties (Fred.Lyon@nrc.gov20140805105600)

Subject:

Acceptance Review (TAC No. MF4429)

Sent Date: 8/5/2014 10:56:35 AM Received Date: 8/5/2014 10:56:00 AM From: Lyon, Fred Created By: Fred.Lyon@nrc.gov Recipients:

"George, Andrea" <Andrea.George@nrc.gov>

Tracking Status: None "Van Der Kamp, David" <dwvande@nppd.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 1250 8/5/2014 10:56:00 AM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:

Recipients Received: