Nucearr Ro-oulatorv Commissin Onperations. Center Event Rennrt Pn"" I Part 21 (PAR)

Event #

50291 Rep Org: FISHER CONTROLS INTERNATIONAL Notification Date I Time: 07/21/2014 16:35 (EDT)

Supplier: FISHER CONTROLS INTERNATIONAL Event Date / Time: 06/26/2014 (CDT)

Last Modification: 07/21/2014 Region: 3 Docket #:

City: Marshalltown Agreement State:

Yes County:

License #:

State: IA NRC Notified by: CHAD ENGLE Notifications:

STEVE ORTH R3DO HQ Ops Officer: DONALD NORWOOD GERALD MCCOY R2DO Emergency Class: NON EMERGENCY PART 21 GROUP EMAIL 10 CFR Section:

21.21 (d)(3)(i)

DEFECTS AND NONCOMPLIANCE PART 21 REPORT - INCORRECT VALVE SOLENOIDS PROVIDED The following is a synopsis of information received via facsimile:

Brunswick Nuclear Plant ordered 10 (ten) 120VAC/6OHz valve solenoids on two purchase orders from Fisher Controls International LLC. In February, 2014, Fisher shipped six 125VDC solenoids to Brunswick. All six of those solenoids were identified as non-conforming prior to installation in the plant. The remaining 4 solenoids at Fisher are on a shipping hold. For technical questions or concerns contact: George Baitinger, Manager, Quality, Fisher Controls International. LLC, 301 South 1st Ave, Marshalltown, IA 50158, Fax: (641) 754--2854, Phone: (641) 754-2026.

Fisher Information Notice: FIN 2014-02

>61-

Jul. 21.

2014 3:09PM No. 0266 P. 1 EMERSON.

[FISHER]

Facsimile 301 South First Ave Marshalltown, IA 50158 T 641-754-3011 F 641-754-2830 To:

NRC Operations Center - Alln:, Bill HUffman Fax:

301-815-5151 From:

Dennis Swanson, Emerson Process Management Date:

712112014 Pages:

4 (inc cover)

Attachment:

Fisher Information Notice - (FIN) 2014-02 For technical questions please contact Dennis Swanson at (641) 754-2381.

Ju,1-21, 2014 3109M No, 0266 P. 2 EMERSON.

Process Management Fisher Controls International LLC 301 South First Ave.

P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 July 21, 2014 To Whom It May Concern:

Attached is a Fisher Information Notice, (FIN) 2014-02.

Emerson Process Management - Fisher Valves complies with the reporting requirements of 10 CFR Part 21 Section 21.21 (b) and 10 CFR Part 50.55 (e) by informing the U.S. Nuclear Regulatory Commission Licensees or Purchaser of deviations or failures to comply.

Please review the attached FIN notice for applicability to your facility.

Dennis Swanson Director, Quality Valve Division - Americas Attachments

[FISHER

,Iul.21. 2014 3:10PM No. 0266 P. 3 EMERSON..

Fisher Controls International LLC Process Management 301 South First Ava.

P.O. Box 190 Marshalitown, Iowa 501 5"-0190 USA T (641) 754-3011 F (641) 754-2830 Fisher Information Notice: FIN 2014-02 July 18, 2014 Subiect: Fisher Orders: 033-F800216042 for Progress Energy -Brunswick 033-F800200404 for Progress Energy -Brunswick From:

Chad Engle Director, Nuclear Business Unit Fisher Controls International LLC 301 South 1tAvenue Marshalltown, IA 50158 Fax: (641) 754-2854 Equipment Affected By This Information Notice:

Items provided to Progress Energy - Brunswick per Fisher Order Number 033-F800216042, Items 0001, 0003, 0004, 0005, 0007, (Progress Energy Purchase Order 592286) and Fisher Order Number 033-F800200404, Item 0002 (Progress Energy Purchase Order 516573). This equipment included 125VDC Solenoids (quantity 6). The solenoids correspond to valves with Fisher Serial Numbers 20659675, 20659677, 20659678, 20659679, 20659681, and 19875287.

Purpose:

The purpose of this Fisher Information Notice (FIN) is to alert Progress Energy-Brunswick that as of 26 June, 2014, Fisher Controls International LLC (Fisher) became aware of the possibility of a situation which may affect the performance of the applicable equipment.

We are informing you of this circumstance in accordance with Section 21.21 (b) of 10CFR21.

Applicability:

This notice applies only to the subject equipment supplied by Fisher, identified above, LFISRIERJ Page 1 of 2

Jul.21, 2014 3:10PM No. 0266 P. 4 Fisher Information Notice: FIN 2014-02 that was provided to Progress Energy -Brunswick.

Discussion Fisher has determined that the subject items did not meet the customer requested construction per the Customer Purchase Orders.

Specifically the discrepancies are:

  • Both Customer Purchase Orders specified 120VAC/6OHz solenoids. Fisher provided solenoids that were 125VDC.

A total of 10 items were ordered between the two Purchase Orders. A quantity of 6 were shipped in February 2014 but all were identified as non-confon-ning prior to installation in the plant. The remaining 4 are on a shipping hold pending solenoid replacement.

Action Required Fisher will support Progress Energy -Brunswick in performing the replacement of the solenoid valves at no cost to Progress Energy-In addition, a Corrective Action Request (CAR) is being initiated by Fisher to prevent this issue from reoccurring.

10CFR21 Implications:

Fisher requests that the recipient of this notice review it and take appropriate action in accordance with 1 OCFR21.

If there are any technical questions or concerns, please contact:

George Baitinger Manager, Quality Fisher Controls International LLC 301 South IMt Avenue Marshalltown, IA 50158 Fax: (641) 754-2854 Phone: (641) 754-2026 GeorTce. BaitingerEmerson.com