TAC:MF1182, DC Electrical Rewrite - Update to TSTF-360, Change in Technical Specifications End States - CE NPSD-1186, Change in Technical Specifications End States - BAW-2441 (Approved, Closed) TAC:MF1199, Change in Technical Specifications End States - CE NPSD-1186, Change in Technical Specifications End States - BAW-2441 (Approved, Closed) |
|
MONTHYEAR1CAN101101, Submittal of Cycle 24 Core Operating Limits Report (COLR)2011-10-31031 October 2011 Submittal of Cycle 24 Core Operating Limits Report (COLR) Project stage: Request 1CAN111103, Unit 1, ANO-1 Cycle 24 Core Operating Limits Report (Colr), Revision 12011-11-11011 November 2011 Unit 1, ANO-1 Cycle 24 Core Operating Limits Report (Colr), Revision 1 Project stage: Request 1CAN111104, Unit 1, ANO-1 Cycle 24 Core Operating Limits Report (Colr), Revision 22011-11-23023 November 2011 Unit 1, ANO-1 Cycle 24 Core Operating Limits Report (Colr), Revision 2 Project stage: Request 2CAN041201, License Amendment Request, Technical Specification (TS) Change Related to Revised Fuel Assembly Drop Analysis and Adoption of TSTF-51, TSTF-272, TSTF-286, and TSTF-4712012-04-0404 April 2012 License Amendment Request, Technical Specification (TS) Change Related to Revised Fuel Assembly Drop Analysis and Adoption of TSTF-51, TSTF-272, TSTF-286, and TSTF-471 Project stage: Request 1CAN041201, Unit 1, ANO-1 Cycle 24 COLR, Revision 32012-04-0404 April 2012 Unit 1, ANO-1 Cycle 24 COLR, Revision 3 Project stage: Request 0CAN071203, Response to Request for Additional Information Related to Proposed Emergency Action Levels Using NEI 99-01 Revision 5 Scheme2012-07-0909 July 2012 Response to Request for Additional Information Related to Proposed Emergency Action Levels Using NEI 99-01 Revision 5 Scheme Project stage: Response to RAI 2CAN071201, License Amendment Request - Supplemental Technical Specification (TS) Change Related to Revised Fuel Assembly Drop Analysis and Adoption of TSTF-51, TSTF-272, TSTF-286, and TSTF-4712012-07-0909 July 2012 License Amendment Request - Supplemental Technical Specification (TS) Change Related to Revised Fuel Assembly Drop Analysis and Adoption of TSTF-51, TSTF-272, TSTF-286, and TSTF-471 Project stage: Supplement 2CAN011301, License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-3602013-01-28028 January 2013 License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-360 Project stage: Request 1CAN011304, License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-3602013-01-28028 January 2013 License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-500, Revision 2 DC Electrical Rewrite - Update to TSTF-360 Project stage: Request 1CAN031306, License Amendment Request, Adoption of Technical Specification Task Force (TSTF)-431, Revision 3 Change in Technical Specifications End States (BAW-2441)2013-03-26026 March 2013 License Amendment Request, Adoption of Technical Specification Task Force (TSTF)-431, Revision 3 Change in Technical Specifications End States (BAW-2441) Project stage: Request 2CAN031303, License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-422, Revision 2 ‘‘Change in Technical Specifications End States (CE NPSD-1186)2013-03-26026 March 2013 License Amendment Request - Adoption of Technical Specification Task Force (TSTF)-422, Revision 2 ‘‘Change in Technical Specifications End States (CE NPSD-1186) Project stage: Request ML13130A2172013-05-10010 May 2013 Acceptance Review Email, License Amendment Request to Adopt Technical Specifications Task Force (TSTF)-431, Revision 3, Change in Technical Specifications End States (BAW-2441) Project stage: Acceptance Review ML13182A3332013-07-0101 July 2013 Acceptance Review Email, License Amendment Request to Adopt Technical Specification Task Force (TSTF)-422, Revision 2 Change in Technical Specifications End States (CE NPSD-1186) Project stage: Acceptance Review ML13261A3532013-09-16016 September 2013 Response to Request for Additional Information Adoption of Technical Specification Task Force (TSTF)-500, Revision 2, DC Electrical Rewrite - Update to TSTF-360 Project stage: Response to RAI ML13301A6752013-10-28028 October 2013 NRR E-mail Capture - RAI Related to the LAR on Adoption of TSTF-431, Revision 3, Change in TS End States (BAW-2441) Project stage: RAI 1CAN111302, Response to Request for Additional Information ANO-1 Adoption of TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441)2013-11-14014 November 2013 Response to Request for Additional Information ANO-1 Adoption of TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441) Project stage: Response to RAI ML13326A3452013-11-22022 November 2013 NRR E-mail Capture - RAI Related to the Adoption of (TSTF)-422, Revision 2 Project stage: RAI 2CAN121303, Response to Request for Additional Information Adoption of Technical Specification Task Force (TSTF)-4222013-12-12012 December 2013 Response to Request for Additional Information Adoption of Technical Specification Task Force (TSTF)-422 Project stage: Response to RAI 2CAN051402, License Amendment Request Supplemental, Adoption of Technical Specification Task Force (TSTF)-500, Revision 2, DC Electrical Rewrite - Update to TSTF-3602014-05-12012 May 2014 License Amendment Request Supplemental, Adoption of Technical Specification Task Force (TSTF)-500, Revision 2, DC Electrical Rewrite - Update to TSTF-360 Project stage: Supplement ML14209A6272014-08-0404 August 2014 Request for Additional Information, Requests to Adopt Technical Specifications Task Force (TSTF)-431, Revision 3, for Unit 1 and TSTF-422, Revision 2 for Unit 2, Change in Technical Specifications End States. Project stage: RAI 0CAN081407, Response to Request for Additional Information Adoption of Technical Specification Task Force TSTF-431, Revision 3 and Adoption of TSTF-422, Revision 2 Regarding Technical Specifications End States2014-08-19019 August 2014 Response to Request for Additional Information Adoption of Technical Specification Task Force TSTF-431, Revision 3 and Adoption of TSTF-422, Revision 2 Regarding Technical Specifications End States Project stage: Response to RAI 2CAN101401, Arkansas, Unit 2 - License Amendment Request Supplemental Adoption of Technical Specification Task Force (TSTF)-422, Revision 2, Change in Technical Specifications End States (CE NPSD-1186)2014-10-22022 October 2014 Arkansas, Unit 2 - License Amendment Request Supplemental Adoption of Technical Specification Task Force (TSTF)-422, Revision 2, Change in Technical Specifications End States (CE NPSD-1186) Project stage: Supplement 1CAN101405, License Amendment Request Supplemental ANO-1 Adoption of TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441)2014-10-22022 October 2014 License Amendment Request Supplemental ANO-1 Adoption of TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441) Project stage: Supplement 2CAN121403, License Amendment Request Supplemental Adoption of Technical Specification Task Force (TSTF)-422, Revision 2, Change in Technical Specifications End States (CE NPSD-1186)2014-12-0505 December 2014 License Amendment Request Supplemental Adoption of Technical Specification Task Force (TSTF)-422, Revision 2, Change in Technical Specifications End States (CE NPSD-1186) Project stage: Supplement 1CAN121403, License Amendment Request Supplemental ANO-1 Adoption of TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441)2014-12-0505 December 2014 License Amendment Request Supplemental ANO-1 Adoption of TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441) Project stage: Supplement ML15023A1472015-03-0303 March 2015 Issuance of Amendment No. 253, Request to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-431, Revision 3, Change in Technical Specifications End States (BAW-2441) Project stage: Approval ML15068A3192015-03-31031 March 2015 Issuance of Amendment No. 301, Request to Adopt Technical Specification Task Force (TSTF)-422, Revision 2, Change in Technical Specifications End States (CE NPSD-1186) Project stage: Approval 2013-03-26
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 4, 2014 Vice President, Operations Arkansas Nuclear One Entergy Operations, Inc.
1448 S.R. 333 Russellville, AR 72802
SUBJECT:
ARKANSAS NUCLEAR ONE, UNIT NOS. 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING LICENSE AMENDMENT REQUESTS TO ADOPT CHANGES TO TECHNICAL SPECIFICATION END STATES (TAC NOS. MF1182 AND MF1199)
Dear Sir or Madam:
By two letters dated March 26, 2013 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML13085A282 and ML13085A283), Entergy Operations, Inc.
(Entergy, the licensee), submitted license amendment requests (LARs) proposing changes to the Technical Specifications (TS) for Arkansas Nuclear One, Units 1 and 2. The proposed amendments would modify the TS requirements for end states associated with the implementation of Technical Specification Task Force (TSTF) traveler TSTF-431, "Change in Technical Specifications End States (BAW-2441 )," for Unit 1, and TSTF-422, Revision 2, "Change in Technical Specifications End States (CE NPSD-1186)," for Unit 2. Both TSTFs may be found at ADAMS Accession No. ML093570241. The proposed end states modifications would permit, for some systems, entry into a hot shutdown (Mode 4) end state rather than the current cold shutdown (Mode 5) end state. Supplements to the LARs were submitted by Entergy on November 14, 2013 (ADAMS Accession No. ML13319A877 for Unit 1), and December 12, 2013 (ADAMS Accession No. ML13347B235 for Unit 2).
The Nuclear Regulatory Commission staff has been reviewing the submittal and has determined that additional information is needed to complete its review. The specific question is found in the enclosed request for additional information (RAI). The question was sent via electronic transmission on July 28, 2014, to Mr. David Bice, of your staff. The draft question was sent to ensure that it was understandable, the regulatory basis was clear, and to determine if the information was previously docketed. After reviewing the draft question, Mr. Bice indicated that there was no need for a clarification teleconference regarding the RAI. The NRC staff requests that you respond within 30 days of the date of this letter.
If you have any questions regarding this matter, I may be reached at 301-415-2833.
Sincerely,
~
Peter J. Bamford, Project Manager Plant Licensing Branch IV-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-313 and 50-368
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUESTS PROPOSING ADOPTION OF TSTF-431, REVISION 3 (UNIT 1) AND TSTF-422, REVISION 2 (UNIT 2)
REGARDING TECHNICAL SPECIFICATION END STATES ENTERGY OPERATIONS, INC.
ARKANSAS NUCLEAR ONE, UNITS 1 AND 2 DOCKET NOS. 50-313 AND 50-368 By two letters dated March 26, 2013 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML13085A282 and ML13085A283), Entergy Operations, Inc.
(Entergy, the licensee), submitted license amendment requests (LARs) proposing changes to the Technical Specifications (TS) for Arkansas Nuclear One (ANO), Units 1 and 2. The proposed amendments would modify the TS requirements for end states associated with the implementation of Technical Specification Task Force (TSTF) traveler TSTF-431, "Change in Technical Specifications End States (BAW-2441)," for Unit 1, and TSTF-422, Revision 2, "Change in Technical Specifications End States (CE NPSD-1186)," for Unit 2. Both TSTFs may be found at ADAMS Accession No. ML093570241. The proposed end states modifications would permit, for some systems, entry into a hot shutdown (Mode 4) end state rather than the current cold shutdown (Mode 5) end state. Supplements to the LARs were submitted by Entergy on November 14, 2013 (ADAMS Accession No. ML13319A877 for Unit 1), and December 12, 2013 (ADAMS Accession No. ML13347B235 for Unit 2). In order for the U.S. Nuclear Regulatory Commission (NRC) staff to complete its review of the LARs, a response to the following request for additional information is requested.
Background:
During the LAR review, the NRC staff noticed that one of the regulatory guidance documents used in the staff's regulatory assessment for the TSTFs, and referenced in the staff's associated model safety evaluations, has since been superseded and therefore, is not valid guidance for the adoption of approved TSTF. The issue concerns a specific reference to Regulatory Guide (RG) 1.182, "Assessing and Managing Risk Before Maintenance Activities at Nuclear Power Plants," contained in both TSTF-431 and TSTF-422.
RG 1.182 was withdrawn since it was determined that the document was redundant due to the inclusion of its subject matter in Revision 3 of RG 1.160, "Monitoring the Effectiveness of Maintenance at Nuclear Power Plants," dated May 2012 (ADAMS Accession No. ML113610098). The withdrawal notice for RG 1.182 was published in the Federal Register on November 27,2012 (78 FR 70846). The notice also states that withdrawal of RG 1.182 neither altered any prior or existing licensing commitments based on its use, nor constituted backfitting as defined in Title 10 of the Code of Federal Regulations (1 0 CFR), Section 50.109 (the Backfit Rule), and was not otherwise inconsistent with the issue finality provisions in 10 CFR Part 52.
Enclosure
In addition, the NRC staff observed that RG 1.160 endorsed Revision 4A of the Nuclear Management and Resources Council (NUMARC) 93-01, "Industry Guideline for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants," dated April 2011 (ADAMS Accession No. ML11116A198). NUMARC 93-01 provides methods that are acceptable to the NRC staff for complying with the provisions of 10 CFR 50.65, "Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants." The model safety evaluation for the TSTFs currently refers to the guidance in Revision 2 of the NUMARC 93-01, dated April 1996 (ADAMS Accession No. ML101020415).
Request for Additional Information:
In order to justify adoption of the TSTF changes, please confirm that ANO, Units 1 and 2, adhere to the RG 1.160 guidance, including the updated version of NUMARC 93-01. In addition, please confirm that the topical reports supporting the LARs comply with NUMARC 93-01, Section 11, and identify, if any, inconsistencies with this section.
ML14209A627 OFFICE NRRJDORL/LPL4-1/PM NRRJDORLILPL4-1/LA NRR/DSS/STSB/BC NRRJDORL/LPL4-1/BC NRRJDORLILPL4-1 /PM NAME PBamford JBurkhardt REIIiott EOesterle PBamford DATE 7/29/14 7/29/14 7/29/14 8/1/14 8/4/14