Grants Request for Temporary Waiver of Compliance to Allow One Time Only Exception for Remainder of Cycle 14 to Allow Power Operation to Continue Until Outage of Sufficient Duration Performed
ML14191A562
Person / Time
Site: Robinson 
Issue date: 09/19/1991
From: Lainas G
Office of Nuclear Reactor Regulation
To: Eury L
Carolina Power & Light Co
References
TAC-81702 NUDOCS 9109260092
Download: ML14191A562 (4)


Text

00 September 19, 1991 DISTRIBUTION Docket No. 50-261 See attac page Mr. Lynn W. Eury Executive Vice President Power Supply Carolina Power & Light Company Post Office Box 1551 Raleigh, North Carolina 27602

Dear Mr. Eury:

SUBJECT:

TEMPORARY WAIVER OF COMPLIANCE - H. B. ROBINSON STEAM ELECTRIC STATION, UNIT NO. 2 (TAC NO. 81702)

By letter dated September 18, 1991, you requested an emergency Technical Specification (TS) Amendment related to Technical Specification Table 3.5-3, Item 3a, for the H. B. Robinson Steam Electric Station, Unit No. 2 (HBR-2).

Your proposed emergency TS amendment would add a footnote to the action statement. This proposed footnote allows a one-time-only exception for the remainder of Cycle 14 that allows power operation to continued until an outage of sufficient duration such that the surveillance test of TS Table 4.1-1, Item 32.a and 4.6.1.2 may be performed.

We have reviewed the Request for Temporary Waiver of Compliance in you September 18, 1991, letter and find it acceptable. Therefore, we confirm the requested Temporary Waiver of Compliance, which was verbally granted on September 18, 1991. A marked-up TS Table 3.5-3, Item 3.a with the footnote for HBR2 is enclosed. This Temporary Waiver of Compliance shall be effective immediately and shall remain in effect until the NRC staff completes processing of Carolina Power & Light Company's request for an emergency TS Amendment dated September 18, 1991.

Sincerely, Fred Hebdon signed for Gus C. Lainas, Assistant Director for Region II Reactors Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

As stated cc:

See next page OFC

PM:PD21:D E
D:PD21:DRP
ADR2 NAME :RLo:d EAdens
GL nas DATE :Y//f /91

///91

/91 OFFICIAL RECORD COPY Document Name:

LETTER EURY TEMP WAIVER 9109260092 910919 PDR ADOCK 05000261 N C FLE C E

R COPY p

PDR

Mr. L. W. Eury H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:

Mr. H. Ray Starling Mr. Dayne H. Brown, Director Manager - Legal Department Department of Environmental, Carolina Power & Ligth Company Health and Natural Resources P. 0. Box 1551 Division of Radiation Protection Raleigh, North Carolina 27602 P. 0. Box 27687 Raleigh, North Carolina 27611-7687 Mr. H. A. Cole Special Deputy Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director P. 0. Box 629 Public Staff - NCUC Raleigh, North Carolina 27602 P. 0. Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Mr. C. R. Dietz Resident Inspector's Office Manager, Robinson Nuclear Project H. B. Robinson Steam Electric Plant Department Route 5, Box 413 H. B. Robinson Steam Electric Plant Hartsville, South Carolina 29550 P. 0. Box 790 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Mr. Heyward G. Shealy, Chief 101 Marietta Street Bureau of Radiological Health Suite 2900 South Carolina Department of Health Atlanta, Georgia 30323 and Environmental Control 2600 Bull Street Mr. R. Morgan Columbia, South Carolina 29201 General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, South Carolina 29550

TABLE 3.5-3 (Continued)

INSTRUMENTATION OPERATING CONDITIONS FOR ENGINKERE SAFETY FEATURES 3

1 2

OPERATOR ACTION NINEMUM HINIMUM IF 00NDITIONS OF CHANNELS DBGRKK OF COLUMN I 0R 2 NO.

FUNCTIONAL UNIT OPERABLE REDUNDANCY CANNOT 85 MET

2.

CONTAINNET SPRAY

a.

Manual*

2 Oth Cold Shutdown

b.

High Containment Fressure*

2/set 1/set Cold Shutdown (111-1i Level)

L

3.

LOSS OF POWER

a.

480W Emerg.

as Udervoltage 2/bus(a) 1/bue(b)

Iata lot Shutdown(d)

(LosS Of Voltage)

b. 480V Emerg. Bus Undervoltage 2/bus I/bus Maintain Not Shutdown(c)

(Degraded Voltage)

Also taitiates a Phase 3 containment isolation.

    • Hat actuate two ewitches stmultaneously.

When primary pressure is less than 2000 paig, channels may be blocked.

When primary temperature is less titan 5470F, channels may be blocked.

r **

In this case the 2/3 high steam flow is already to the trip mode.

6s (a)

During testing and mainteance of one channel, may be reduced to i/bus.

o (b)

During testing and maatenance of one channel. may be reduced to 0/bus.

(c)

The reactor may remain critical below the power operating condltione with this feature Inhibited for m

the purpose of starting reactor coolant pumps.

(d) A one-time-only exception is granted that allows power operation to continue with the actuation a

circuitry of this Specification inoperable due solely to the inability of the surveillance procedure for TS Table 4.1-1. Item 32a and TS 4.6.1.2 to adequately assess operability of the affected circuits.

The duration of this exception is limited to the first outage of sufficient length which allows performance of a surveillance test which adequately tests the affected circuits but not later than Refueling outage 14.

DISTRIBUTION Docket File NRC PDR Local PDR S. Varga 14-E-4 G. Lainas 14-H-3 L. Reyes RH E. Adensam 14-8-20 P. Anderson 14-B-20 R. Lo 14-8-20 OGC 15-B-18 E. Jordan MNBB-3701 ACRS (10)

P-315 Robinson Plant File cc:

Plant Service list