7 ECEMIBER 1979 Docket No. 50-261 LICENSEE: Carolina Power and Light Company FACILITY: H. B. Robinson Steam Electric Plant, Unit No.. 2

SUBJECT:

SUMMARY

OF DECEMBER 3, 1979 PHONE CONVERSATION REGARDING LESSONS LEARNED IMPLEMENTATION During a phone conversation on December 3, 1979, the NRC Lessons Learned Implementation Team informed the licensee that its November 20, 1979 response to NRC October 30, 1979 letter was satisfactory. However, the team did clarify the NRC position on containment valve isolation - that thelre should be no group restt switch for these valves.

Persons participating in the conversation were Don Neighbors, Newt Anderson and Janis Kerrigan of the NRC and Joe Sheppard of Carolina Power and Light Company.

Original signed by Don Neighbors, Project Manager Operating Reactors Branch #1 Division of Operating Reactors cc: See next page oF~c 00 1

0 111 SURNAME 00D-i bb sph 8

1_O DATE 0 I2I L79 J_

Z_

NRC.Form 318B (479) NRCM 0240 NRCFom 188(479 NR M

24 US.

GOVERNIVE NT PRINTING OFF.ICE:,197 9-2 404

P' REG(.,

105 UNITED STATES 0

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 DECEMBlER 1 4 1979 Docket No. 50-261 LICENSEE:

Carolina Power and Light Company FACILITY: H. B. Robinson Steam Electric Plant, Unit No. 2

SUBJECT:

SUMMARY

OF DECEMBER 3, 1979 PHONE CONVERSATION REGARDING LESSONS LEARNED IMPLEMENTATION During a phone conversation on December 3, 1979, the NRC Lessons Learned Implementation Team informed the licensee that its November 20, 1979 response to NRC October 30, 1979 letter was satisfactory. However, the team did clarify the NRC position on containment valve isolation - that there should be no group reset switch for these valves.

Persons participating in the conversation were Don Neighbors, Newt Anderson and Janis Kerrigan of the NRC and Joe Sheppard of Carolina Power and Light Company.

Don NeighborY, Project Manager Operating Reactors Branch #1 Division of Operating Reactors cc:

See next page December 14, 1979 Meeting Summary for Carolina Power and Light Docket Files NRC PDR Local PdR G. F. Trowbridge, Esquire ORB1 Reading Shaw, Pittman, Potts and Trowbridge NRR Reading 1800 M Street, N.W.

H. Denton Washington, D. C. 20036 E. Case D. Eisenhut Hartsville Memorial Library R. Tedesco Home and Fifth Avenues G. Zech Hartsville, South Carolina 29550 B. Grimes W. Gammill Michael C. Farrar, Chairman L. Shao Atomic Safety and Licensing J. Miller Appeal Board Panel R. Vollmer U. S. Nuclear Regulatory Commission T. J. Carter Washington, D. C. 20555 S

A. Schwencer D. Ziemann Richard S. Salzman P. Check Atomic Safety and Licensing G. Lainas Appeal Board Panel D. Crutchfield U. S. Nuclear Regulatory Commission

8. Grimes Washington, D. C. 20555 T. Ippolito R. Reid Dr. W. Reed Johnson V. Noonan Atomic Safety and Licensing G. Knighton Appeal Board Panel D. Brinkman U. S. Nuclear Regulatory Commission Project Manager Washington, D. C. 20555 OELD 0I&E (3)

C. Parrish/P. Kreutzer ACRS (16)

.NkC Participants NSIC TERA Short Service List