May 31, 1989 Docket Nos. 0-325, 50-324 50-261 50-400 Mr. Lynn W. Eury Executive Vice President Power Supply Carolina Power & Light Company Post Office Box 1551 Raleigh, North Carolina 27602
Dear Mr. Eury:
SUBJECT:
USE OF ASME CODE CASE N-356; BRUNSWICK STEAM ELECTRIC PLANT, UNITS 1 AND 2, H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2, SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 (TAC NOS.
72940/72941/72942/72943)
In a letter dated April 10, 1989, the Carolina Power & Light Company requested approval of the use of Code Case N-356, "Certification Period for Level III NDE Personnel," for inclusion in the Section XI ISI Programs at Brunswick Steam Electric Plant, Units 1 and 2, H. B. Robinson Steam Electric Plant, Unit No. 2, and Shearon Harris Nuclear Power Plant, Unit 1. Code Case N-356 permits extending the certification of Level III NDE Personnel from three to five years.
The NRC staff has recently reviewed Code Case N-356 and approved its use in the Section XI ISI Program at the Hope Creek and Salem, Unit 1 and 2, Generating Station (letter from the staff to Public Service Electric and Gas Company dated May 17, 1989). Therefore, Code Case N-356 may be included in the Section XI ISI Program at the subject facilities as requested.
Sincerely, Original Signed By:
Ronnie Lo, Senior Project Manager Project Directorate II-1 Division of Reactor Projects -I/II Office of Nuclear Reactor Regulation cc: See next page DISTRIBUTION Docket File NRC PDR Local PDR PDII-1 r/f S. Varga G. Lainas E. Adensam P. Anderson R. Lo D. Becker E. Tourigny OGC 15-B-18 E. Jordan MNBB-3302 B. Grimes 9-A-2 CYCheng 9-H-15 ACRS (10)
P-315 F. Litton 9-H-15 PM:PDI PM 1
PM:PDII4 D:PDII-1 Pn RLo:sw E1 rig y RBecke EAdensa 5/ 1/89 5/4 1/8e 5/V89 45//89 135/j///89
,CAO3C&
Mr. L. W. Eury Brunswick Steam Electric Plant Carolina Power & Light Company Units 1 and 2 cc:
Mr. Russell B. Starkey, Jr.
Mr. J. L. Harness Project Manager Plant General Manager Brunswick Nuclear Project Brunswick Steam Electric Plant P. 0. Box 10429 P. 0. Box 10429 Southport, North Carolina 28461 Southport, North Carolina 28461 Mr. R. E. Jones, General Counsel Mr. H. A. Cole Carolina Power & Light Company Special Deputy Attorney General P. 0. Box 1551 State of North Carolina Raleigh, North Carolina 27602 P. 0. Box 629 Raleigh, North Carolina 27602 Mr. Mark S. Calvert Associate General Counsel Mr. Robert P. Gruber Carolina Power & Light Company Executive Director P. 0. Box 1551 Public Staff - NCUC Raleigh, North Carolina 27602 P. 0. Box 29520 Raleigh, North Carolina 27626-0520 Ms. Grace Beasley Board of Commissioners P. 0. Box 249 Bolivia, North Carolina 28422 Mrs. Chrys Baggett State Clearinghouse Budget and Management 116 West Jones Street Raleigh, North Carolina 27603 Resident Inspector U. S. Nuclear Regulatory Commission Star Route 1 P. 0. Box 208 Southport, North Carolina 28461 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, Suite 2900 Atlanta, Georgia 30323 Mr. Dayne H. Brown, Chief Radiation Protection Branch Division of Facility Services N. C. Department of Human Resources 701 Barbour Drive Raleigh, North Carolina 27603-2008
Mr. L. W. Eury H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:
Mr. R. E. Jones, General Counsel Mr. Dayne H. Brown, Chief Carolina Power & Light Company Radiation Protection Branch P. 0. Box 1551 Division of Facility Services Raleigh, North Carolina 27602 Department of Human Resources 701 Barbour Drive Raleigh, North Carolina 27603-2008 Mr. McCuen Morrell, Chairman Darlington County Board of Supervisors Mr. Robert P. Gruber County Courthouse Executive Director Darlington, South Carolina 29535 Public Staff - NCUC P. 0. Box 29520 Mr. H. A. Cole Raleigh, North Carolina 27626-0520 Special Deputy Attorney General State of North Carolina Mr. C. R. Dietz P. 0. Box 629 Manager, Robinson Nuclear Project Raleigh, North Carolina 27602 Department H. B. Robinson Steam Electric Plant Mr. D. E. Hollar P. 0. Box 790 Associate General Counsel Hartsville, South Carolina 29550 Carolina Power & Light Company P. 0. Box 1551 Attorney General Raleigh, North Carolina 27602 P. 0. Box 11549 Columbia, South Carolina 29211 U.S. Nuclear Regulatory Commission Resident Inspector's Office Mr. Heyward G. Shealy, Chief H. B. Robinson Steam Electric Plant Bureau of Radiological Health Route 5, Box 413 South Carolina Department of Health Hartsville, South Carolina 29550 and Environmental Control 2600 Bull Street Regional Administrator, Region II Columbia, South Carolina 29201 U.S. Nuclear Regulatory Commission 101 Marietta Street Suite 2900 Atlanta, Georgia 30323 Mr. R. Morgan General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, South Carolina 29550
Mr. L. W. Eury Carolina Power & Light Company Shearon Harris cc:
Mr. R. E. Jones, General Counsel Nuclear Energy Public Information Carolina Power & Light Company Committee P. 0. Box 1551 c/o Triangle J Council of Governments Raleigh, North Carolina 27602 P. 0. Box 12276 Research Triangle Park, NC 27709 Mr. D. E. Hollar Associate General Counsel Regional Administrator, Region II Carolina Power & Light Company U.S. Nuclear Regulatory Commission P. 0. Box 1551 101 Marietta Street Raleigh, North Carolina 27602 Suite 2900 Atlanta, Georgia 30323 Resident Inspector/Harris NPS c/o U. S. Nuclear Regulatory Commission Mr. C. S. Hinnant Route 1, Box 315B Plant General Manager New Hill, North Carolina 27562 Harris Nuclear Plant P. 0. Box 165 Mr. R. A. Watson New Hill, North Carolina 27562 Vice President Harris Nuclear Plant Mr. Dayne H. Brown, Chief P. 0. Box 165 Radiation Protection Section New Hill, North Carolina 27562 Division of Facility Services N. C. Department of Human Resources Mr. H. A. Cole 701 Barbour Drive Special Deputy Attorney General Raleigh, North Carolina 27603-2008 State of North Carolina P. 0. Box 629 Raleigh, North Carolina 27602