ML14184A976
| ML14184A976 | |
| Person / Time | |
|---|---|
| Site: | Robinson |
| Issue date: | 07/10/1992 |
| From: | Cline W NRC Office of Inspection & Enforcement (IE Region II) |
| To: | Watson R Carolina Power & Light Co |
| References | |
| NUDOCS 9208070064 | |
| Download: ML14184A976 (3) | |
Text
JUL 10 IM2 Docket No. 50-261 License No. DPR-23 Carolina Power and Light Company ATTN: Mr. R. A. Watson Senior Vice President Nuclear Generation P. O..Box 1551 Raleigh, NC 27602 Gentlemen:
SUBJECT:
FEMA OFFSITE EXERCISE REPORT FOR H. B. ROBINSON NUCLEAR POWER STATION Please find enclosed a copy of the Federal Emergency Management Agency's (FEMA) Report for the offsite portion of the H. B.
Robinson Nuclear Power Station Exercise conducted on November 20, 1991.
As described in the enclosure, there were no deficiencies identi fied during this exercise. However, eight Areas Requiring Corrective Action (ARCAs) were identified. These ARCAs involved training of radiological monitors in Darlington, Lee, and Flor ence Counties, improving overall shelter planning and operations in Lee County, information and warning signs in Darlington County, not having TLDs or film badges in emergency decontamina tion worker kits in Chesterfield County, vehicle decontamination procedures in Chesterfield County, and providing for the review of EBS messages at the Forward Emergency Operations Center.
We encourage you to assist the appropriate organizations in resolving the corrective actions and improvement items identified by FEMA. Resolution of these items should be completed prior to the next full-scale emergency preparedness exercise.
We also encourage you to work closely with the State and counties in the development of a scenario of the next full-scale exercise that will effectively test the areas in which the above items were disclosed.
9208070064 920710 F
PDR ADOCK 05000261 F
PDR 0__
_ _ ~
Carolina Power and 2
Light Company Your cooperation in this matter is appreciated.
Sincerely, ORIGINAL SIGNED BY WILLIAM E. CLINE William E. Cline, Chief Radiological Protection and Emergency Preparedness Branch Division of Radiation Safety and Safeguards
Enclosure:
Fema Report cc w/encl:
C. R. Dietz Vice President Robinson Nuclear Project Department H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, SC 29550 R. H. Chambers Plant General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, SC 29550 Heyward G. Shealy, Chief Bureau of Radiological Health Dept. of Health and Environmental Control 2600 Bull Street Columbia, SC 29201 Dayne H. Brown, Director Division of Radiation Protection N. C. Department of Environment, Health & Natural Resources P. 0. Box 27687 Raleigh, NC 27611-7687 (cc w/encl cont'd on page 3)
Carolina Power and 3
Light Company (cc w/encl cont'd)
McCuen Morrell, Chairman Darlington County Board of Supervisor County Courthouse Darlington, SC 29535 H. Ray Starling Manager -
Legal Department Carolina Power and Light Co.
P. 0. Box 1551 Raleigh, NC 27602 H. A. Cole Special Deputy Attorney General State of North Carolina P. 0. Box 629 Raleigh, NC 27602 Robert Gruber Executive Director Public Staff -
NCUC P. 0. Box 29520 Raleigh, NC 27626-0520 J. D. Kloosterman, Director Regulatory Compliance H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, SC 29550 bcc w/encl:
H. Christensen, RII B. Mozafari, NRR Document Control Desk NRC Resident Inspector U. S. Nuclear Regulatory Commission Route 5, Box 413 Hartsville, SC 295502 RII: RSS RII:DRSS RII: R~
RII CBa ks JHUi WHRankin HCAistensen
'7/1/92 1///92 7/k92 17/92