ACCELERATED DISTRIBUTION DEMONS ON SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9110100177 DOC.DATE: 91/10/10 NOTARIZED: YES DOCKET #

FACIL:50-261 H.B. Robinson Plant, Unit 2, Car ina ower & Light C 05000261 AUTH.NAME AUTHOR AFFILIATION

/

/'9 FLOYDS.D.

Carolina Power & Light Co.

RECIP.NAME RECIPIENT AFFILIATION A37/

Document Control Branch '(Document Control Desk)

R

SUBJECT:

Forwards nonproprietary WCAP-13072 & proprietary WCAP-13071, "Evaluation of Revised Transfer to Cold Leg Recirculation Procedure,HB Robinson Unit 2." Proprietary WCAP-13071 D

withheld (ref 10CFR2.790).

DISTRIBUTION CODE: AP01D COPIES RECEIVED:LTR I ENCL 5 IZE:jLJIL23I S

TITLE: Proprietary Review Distribution -

OperaFing Reactor NOTES:

A RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL D

PD2-1 LA 1

1 PD2-1 PD 1

1 LO,R 3

3 D

INTERNAL: AEOD/D 1

1 OGC/HDS2 1

0 S

~REILE==Om 1

1 EXTERNAL: NRC DR 1

0 R

I D

S A

D D

NOTE TO ALL "RIDS" RECIPIENTS:

S PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P1-37 (EXT. 20079) TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED: LTTR ENCL d

AA2-

arolina Power & Light Company Nuclear Services Department 411 Fayetteville Street Mall - P.O. Box 1551 Raleigh, North Carolina 27602 OCT 4 1991 SERIAL:

NLS-91-243 United States Nuclear Regulatory Commission ATTENTION:

Document Control Desk Washington, DC 20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261/LICENSE NO. DPR-23 SUBMITTAL OF WCAP-13071 AND WCAP-13072 Gentlemen:

Enclosed are copies of WCAP-13071 (five copies - proprietary) and WCAP-13072 (one copy - nonproprietary) entitled, "An Evaluation of the Revised Transfer to Cold Leg Recirculation Procedure, H. B. Robinson Unit 2."

These documents present the results of calculations performed for both large-and small-break events to determine if the termination of all Safety Injection pumps during the switchover to recirculation procedure is justifiable with only a single high head Safety Injection pump available. The calculations were based upon an interruption period of three minutes following a large-break LOCA and as much as ten minutes following a small-break LOCA. The work was undertaken to address concerns voiced in ongoing discussions between Carolina Power & Light Company and the NRC, which culminated in a meeting in Raleigh on July 17, 1991.

Since Attachment 1 contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.

Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations.

Correspondence with respect to the copyright or proprietary aspects of the items listed above or the supporting Westinghouse Affidavit should reference CAW-91-212 and should be addressed to R. P. DiPiazza, Manager of Nuclear Safety Licensing, Westinghouse Electric Corporation, P. 0. Box 355, Pittsburgh, Pennsylvania 15230-0355.

10100177 911010 PDR ADOCK 050002.1 F -

PDR

Document Control Des (NLS-91-243) / Page Questions regarding application of the WCAPs to H. B. Robinson Steam Electric Plant, Unit 2 should be directed to Mr. R. W. Prunty at (919) 546-7318.

Yours very truly, S. D. Floyd Manager Nuclear Licensing Section JSK/jbw (1295RNP)

Enclosures:

1. WCAP-13071
2. WCAP-13072
3. Proprietary Information Notice
4. Copyright Notice
5. Westinghouse Letter, "Application for Withholding Proprietary Information from Public Disclosure" (CAW-91-212) with Affidavit CAW-91-212
  • cc:

Mr. S. D. Ebneter Mr. L. Garner (NRC-HBR)

Mr. R. Lo

  • Without enclosures