Mr. C. S. Hinnant, VicPresident u

Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, South Carolina 29550

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2, CONCERNING REACTOR TRIP AND ENGINEERED SAFETY FEATURE ACTUATION SYSTEMS INSTRUMENTATION (TAC NO. M94318)

Dear Mr. Hinnant:

On December 10, 1995, you submitted an amendment request regarding reactor trip and engineered safety feature actuation systems instrumentation technical specifications (TS) for the H. B. Robinson Steam Electric Plant, Unit No. 2.

As a result of our review, we have determined a need for the following request for additional information (RAI).

1.

NUREG-0452, Revision 3, for Table 3.5-2 Functional Unit, Manual, requires Action 13, Reactor Trip System Instrumentation, which states that with the number of operable channels one less than the Minimum Channels OPERABLE requirement, restore the inoperable channel to operable status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or open the reactor trip breakers within the next hour. Explain the difference between NUREG-0452 and your revision.

2.

Likewise, Action 13 is required for Functional Unit, Source Range, Neutron.Flux. Explain your deviation from NUREG-0452.

3.

Provide the reference documents and pages for the parts of NUREG-0452 corresponding to Insert 6 for Table 3.5-3 Functional Units E and F (page 3.5-14).

Your written response to the RAI is expected within 30 days of the receipt of this letter.

Sincerely, (Original Signed BY)

Brenda Mozafari, Project Manager Project Directorate II-1 Division of Reactor Projects -

I/II Office of Nuclear Reactor Regulation Distribution Docket File FGee Docket No. 50-261 PUBLIC EWeiss PDII-1 RF JWermiel SVarga ACRS cc:

See next page JZwolinski OGC FILENAME -

G:\\ROBINSON\\ROB94318.RAI OFFICE LA:PDII-1 PM:PDII-1 D:PDII-1 NAME EDunnington BMozafari EImbr6i#A fl.

DATE 07/30/96 e7b430/96 07/)p/96 COPY

[No Yes No Yes/No)

OFFICIAI ECORD COPY 9608010241 960730

}19 PDR ADOCK 05000261 th, t Q P

PDR

Mr. C. S. Hinnant H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:

Mr. William D. Johnson Mr. Dayne H. Brown, Director Vice President and Senior Counsel Department of Environmental, Carolina Power & Light Company Health and Natural Resources Post Office Box 1551 Division of Radiation Protection Raleigh, North Carolina 27602 Post Office Box 27687 Raleigh, North Carolina 27611-7687 Ms. Karen E. Long Assistant Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director Post Office Box 629 Public Staff - NCUC Raleigh, North Carolina 27602 Post Office Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Resident Inspector's Office Mr. Max Batavia, Chief H. B. Robinson Steam Electric Plant South Carolina Department of Health 2112 Old Camden Road Bureau of Radiological Health Hartsville, South Carolina 29550 and Environmental Control 2600 Bull Street Regional Administrator, Region II Columbia, South Carolina 29201 U.S. Nuclear Regulatory Commission 101 Marietta St., N.W., Ste. 2900 Mr. J. Cowan Atlanta, Georgia 30323 Manager Nuclear Services and Environmental Mr. Dale E. Young Support Department Plant General Manager Carolina Power & Light Company Carolina Power & Light Company Post Office Box 1551 - Mail 0HS7 H. B. Robinson Steam Electric Plant Raleigh, North Carolina 27602 3581 West Entrance Road Hartsville, South Carolina 29550 Mr. Milton Shymlock U. S. Nuclear Regulatory Commission Public Service Commission 101 Marietta Street, N.W. Suite 2900 State of South Carolina Atlanta, Ga. 3023-0199 Post Office Drawer 11649 Columbia, South Carolina 29211 Mr. R. M. Krich Manager - Regulatory Affairs Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, South Carolina 29550