June 9, 1995 Mr. C. S. Hinnant, Vice President Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, South Carolina 29550
SUBJECT:
EVALUATION OF REQUEST TO REVISE A SAFETY EVALUATION CONDITON FOR RELIEF NO. 13 OF THE THIRD 10-YEAR INTERVAL INSERVICE INSPECTION FOR THE H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2.
Dear Mr. Hinnant:
The NRC staff has reviewed and evaluated the information provided by Carolina Power & Light Company in its letter dated June 6, 1995, related to the third 10-year interval inservice inspection request to revise Relief No. 13 for the H. B. Robinson Steam Electric Plant, Unit 2. We have concluded that the disassembly of the reactor coolant pump (RCP) for the sole purpose of performing inspections 'of the internal surfaces would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety. Public health and safety will not be endangered by allowing a one time exception from the conditions imposed in granting Relief No. 13.
Therefore, a one-time exception from performing inspections of the RCP internal surfaces is granted pursuant to 10 CFR 50.55a(a)(3)(ii).
The NRC staff's evaluation and conclusions are contained in the enclosed Safety Evaluation.
Sincerely,
/s/
Bart C. Buckley, Acting Director Project Directorate II-1 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation Docket No. 50-261
Enclosure:
Safety Evaluation cc w/enclosure:
See next page FILENAME - G:\\ROBINSON\\ROB92461.RLF *See Previous Concurrence OFFICE L PW PM:
AD:,DIO-1 0GC*
NAME D ning tn B
ari BBuckl ey DATE 6/ 1/95 0_/
/95
&/
'/95 06/9/95 COPY Yes/No Yes/No Yes/No Yes/No OFFICIAL RECORD COPY 9506290643 950609 PDR ADOCK 05000261 C
TOPY G
PDR FILE
Mr. C. S. Hinnant H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:
Mr. R. E. Jones Mr. Dayne H. Brown, Director General Counsel - Legal Department Department of Environmental, Carolina Power & Light Company Health and Natural Resources Post Office Box 1551 Division of Radiation Protection Raleigh, North Carolina 27602 Post Office Box 27687 Raleigh, North Carolina 27611-7687 Karen E. Long Assistant Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director Post Office Box 629 Public Staff - NCUC Raleigh, North Carolina 27602 Post Office Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Resident Inspector's Office Mr. Max Batavia, Chief H. B. Robinson Steam Electric Plant South Carolina Department of Health 2112 Old Camden Road Bureau of Radiological Health Hartsville, South Carolina 29550 and Environmental Control 2600 Bull Street Regional Administrator, Region II Columbia, South Carolina 29201 U.S. Nuclear Regulatory Commission 101 Marietta St., N.W., Ste. 2900 Mr. H. W. Habermeyer, Jr.
Atlanta, Georgia 30323 Vice President Nuclear Services Department Mr. Dale E. Young Carolina Power & Light Company Plant General Manager Post Office Box 1551 Carolina Power & Light Company Raleigh, North Carolina 27602 H. B. Robinson Steam Electric Plant 3581 West Entrance Road Hartsville, South Carolina 29550 Public Service Commission State of South Carolina Post Office Drawer 11649 Columbia, South Carolina 29211 Mr. R. M. Krich Manager -
Regulatory Affairs Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, South Carolina 29550
DISTRIBUTION PUBLIC Docket File NRC & Local PDRs PD21 Reading File SVarga DMatthews GBagchi GGeorgiev OGC ACRS (4)