ML14178A791
| ML14178A791 | |
| Person / Time | |
|---|---|
| Site: | Robinson |
| Issue date: | 12/08/1994 |
| From: | Gibson A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Hinnant C CAROLINA POWER & LIGHT CO. |
| References | |
| GL-89-10, NUDOCS 9412280147 | |
| Download: ML14178A791 (25) | |
Text
December 8, 1994 Carolina Power and Light Company ATTN:
Mr. C. S. Hinnant Vice President H. B. Robinson Steam Electric Plant Unit 2 P. 0. Box 790 Hartsville, SC 29550-0790
SUBJECT:
MEETING
SUMMARY
MOTOR-OPERATED VALVE ISSUES WITH SPECIAL EMPHASIS ON THE PROCESS FOR CLOSING OUT GENERIC LETTER 89-10 Gentlemen:
On November 8, 1994, Region II and the Office of Nuclear Reactor Regulation (NRR) held a meeting with all Region II licensees/applicants on the closeout process for Generic Letter 89-10 (GL 89-10), Motor-Operated Valves. During this meeting Region II and NRR representatives provided the staff position on GL 89-10 closeout and answered questions on the inspection process. Handouts presented during this meeting are enclosed.
Periodic verification of motor-operated valve performance, after completion of GL 89-10 closeout, was an area of concern voiced by the audience. Many licensee representatives expressed their concern about continued dynamic testing of motor-operated valves after completion of the closeout process with little to no benefit. In response, the NRC staff agreed to revisit this issue and provide further information during future industry meetings.
This meeting was a valuable contribution to improving communications between the NRC and licensees/applicants.
I want to express my gratitude for all those who attended. Thank you for your cooperation.
Sincerely, Original signed by Bruce S. Mallett for:
9412280147 941208 Albert F. Gibson, Director PDR ADOCK 05000261 Albert f Gibsor Safety P
PDR Division of Reactor Safety Docket No. 50-261 Licensee No. DPR-23
Enclosure:
Handouts Distribution w/encls:
W. Orders, SRI PUBLIC SEND OFC RII:DRS RII:DRS RII:
NRR:EMER TO NAME CCas(
d RCrtenjak RWessman PDR?
DATE 4 /3V
/94 IV/1 ly/94
/ f/94
/
94
/
/94 Yes No COPY?
Yes Yes No Yes No Yes Yes No OFFICIAL RECORD COPY DOCUMENT NAME:
A:\\MOVGL.LTR
PROCESS FOR CLOSURE OF STAFF REVIEW OF GENERIC LETTER 89-10 PROGRAMS AND PERIODIC VERIFICATION OF MOV DESIGN-BASIS CAPABILITY TERENCE L. CHAN CHIEF, COMPONENTS AND TESTING SECTION MECHANICAL ENGINEERING BRANCH OFFICE OF NUCLEAR REACTOR REGULATION U.S. NUCLEAR REGULATORY COMMISSION
PROCESS FOR CLOSURE OF STAFF REVIEW OF GENERIC LETTER 89-10 PROGRAMS PURSUANT TO 10 CFR 50.54(F), GL 89-10 STATES THAT LICENSEES SHALL NOTIFY NRC IN WRITING WITHIN 30 DAYS AFTER COMPLETION OF GL 89-10 DESIGN-BASIS VERIFICATION.
NRC STAFF MEMORANDUM DATED JULY 12, 1994, DESCRIBES THE PROCESS FOR CLOSURE OF THE STAFF'S REVIEW OF THE DESIGN-BASIS VERIFICATION PORTION OF LICENSEES' GL 89-10 PROGRAMS.
WHEN A LICENSEE NOTIFIES NRC OF COMPLETION OF ITS GL 89-10 PROGRAM, NRR PROJECT MANAGER WILL SET UP DISCUSSION BETWEEN NRR TECHNICAL STAFF AND REGION STAFF TO DISCUSS CLOSURE OF NRC STAFF REVIEW OF GL 89-10 PROGRAM.
FOLLOWING THOSE DISCUSSIONS, NRR PROJECT MANAGER WILL NOTIFY LICENSEE OF ANY NECESSARY INFORMATION TO CLOSE GL 89-10 OR SET UP TELEPHONE CONFERENCE TO DISCUSS CLOSURE OF STAFF REVIEW BY INSPECTION OR LICENSEE SUBMITTAL.
UPON SATISFACTORY COMPLETION OF NRC STAFF REVIEW, STAFF WILL CLOSE GL 89-10 REVIEW THROUGH LETTER FROM NRR PROJECT MANAGER OR COVER LETTER OF INSPECTION REPORT.
SUPPLEMENTAL INSPECTION GUIDANCE FOR CLOSURE OF STAFF REVIEW OF GL 89-10 PROGRAMS 04.04 SELECT SAMPLE OF MOVs FOR DETAILED REVIEW FROM THE POPULATION OF MOVs IN THE GL 89-10 PROGRAM.
LICENSEE IS EXPECTED TO HAVE VERIFIED DESIGN BASIS CAPABILITY OF EACH MOV IN ITS GL 89-10 PROGRAM. LICENSEE SHOULD HAVE AVAILABLE SPECIFIC STATUS FOR EACH GL 89-10 MOV.
PWR LICENSEE MAY DEFER CONSIDERATION OF VALVE' MISPOSITIONING. STAFF REVIEW MAY BE CLOSED IF LICENSEE COMMITS TO CONSIDER MISPOSITIONING IN THE EVENT THAT STAFF DETERMINES THIS RECOMMENDATION REMAINS APPROPRIATE.
04.05 VERIFY THAT LICENSEE HAS PERFORMED DESIGN BASIS REVIEWS OF SAMPLED MOVs.
INSPECTORS WILL ASSESS THE PROGRESS BEING MADE BY LICENSEES IN ADDRESSING PRESSURE LOCKING AND THERMAL BINDING OF GATE VALVES.
SUPPLEMENT 6 TO GL 89-10 PROVIDES INFORMATION ON PRESSURE LOCKING AND THERMAL BINDING OF GATE VALVES.
SUPPLEMENTAL INSPECTION GUIDANCE (CONTINUED) 04.06 VERIFY THAT LICENSEE HAS ADEQUATELY SIZED SAMPLED MOVs.
INFORMATION ON SIZING AND SETTING PROVIDED IN APRIL 30, 1993, MEMORANDUM FROM NRR TO REGIONS AND IN SUPPLEMENT 6 TO GL 89-10.
04.07 VERIFY THAT LICENSEE HAS DEMONSTRATED DESIGN BASIS CAPABILITY OF SAMPLED MOVs.
INSPECTORS WILL VERIFY IMPLEMENTATION OF LICENSEE ACTIONS IN RESPONSE TO SUPPLEMENT 5' TO GL 89-10 ON MOV DIAGNOSTIC EQUIPMENT ACCURACY. INSPECTORS WILL ASSESS ADEQUACY OF LICENSEE'S TREATMENT OF MEASUREMENT ERROR IN THE ANALYSIS OF TEST DATA AND TORQUE SWITCH SETPOINT ANALYSIS.
SUPPLEMENT 6 TO GL 89-10 PROVIDES INFORMATION ON DEMONSTRATION OF MOV DESIGN-BASIS CAPABILITY, INCLUDING GROUPING.
04.08 VERIFY THAT THE LICENSEE HAS ESTABLISHED A METHOD FOR PERIODIC VERIFICATION.
[DETAILS ON A FOLLOWING SLIDE]
00 SUPPLEMENTAL INSPECTION GUIDANCE (CONTINUED) 04.09 VERIFY THAT LICENSEE HAS ANALYZED MOV FAILURES AND HAS EFFECTIVE CORRECTIVE ACTION PLAN, AND THAT LICENSEE TRENDS MOV FAILURES.
INSPECTORS WILL CONSIDER LICENSEE RESPONSE TO NRC INFORMATION NOTICES, INDUSTRY TECHNICAL AND MAINTENANCE UPDATES, AND 10 CFR PART 21 NOTICES.
04.10 VERIFY THAT THE LICENSEE IS MEETING PROGRAM SCHEDULE.
SUPPLEMENT 6 TO GL 89-10 PROVIDES GUIDANCE FOR LICENSEES THAT CANNOT MEET GL 89-10 SCHEDULE COMMITMENTS.
04.11 VERIFY QUALITY ASSURANCE PROGRAM IMPLEMENTATION IN DESIGN CONTROL AND TESTING.
PREVIOUS INSPECTION ISSUES INSPECTORS WILL REVIEW RESOLUTION OF PREVIOUS INSPECTION ISSUES, SUCH AS JUSTIFICATION FOR THE GL 89-10 PROGRAM ASSUMPTIONS (VALVE FACTOR, STEM FRICTION COEFFICIENT, LOAD SENSITIVE BEHAVIOR, AND OTHERS)
POST CLOSEOUT INSPECTIONS
- 1.
REACTIVE LIMITED - WILL TYPICALLY ADDRESS ADEQUACY OF FAILURE EVALUATIONS AND CORRECTIVE ACTIONS
- 2.
MAINTENANCE RULE BROAD - PERIODIC VERIFICATION, TRENDING, LUBRICATION, POST MAINTENANCE/MODIFICATION TESTING, ETC.
- 3.
POSSIBLE FOLLOWUP MODULE
CLOSURE OF NRC STAFF REVIEW OF GENERIC LETTER 89-10 PROGRAMS THOMAS G. SCARBROUGH MECHANICAL ENGINEERING BRANCH OFFICE OF NUCLEAR REACTOR REGULATION U.S. NUCLEAR REGULATORY COMMISSION
STATUS OF GENERIC LETTER 89-10 CLOSURE STAFF COMPLETED OUR REVIEW OF THE GL 89-10 PROGRAM AT THE CALLAWAY NUCLEAR POWER PLANT.
OTHER NUCLEAR PLANTS THAT HAVE NOTIFIED THE STAFF OF THE COMPLETION OF THE DESIGN-BASIS CAPABILITY VERIFICATION PORTION OF THEIR GL 89-10 PROGRAMS INCLUDE:
COMANCHE PEAK 1 AND 2 CRYSTAL RIVER FARLEY 1 AND 2 FORT CALHOUN HARRIS HATCH 1 AND 2 HOPE CREEK LIMERICK 1 PALO VERDE 3 POINT BEACH 1 AND 2 PRAIRIE ISLAND 1 AND 2 ROBINSON SOUTH TEXAS 1 AND 2 TURKEY POINT 3 WATERFORD BASED ON AGREEMENT BETWEEN THE LICENSEE AND NRC STAFF, FORT CALHOUN IS SUBMITTING INFORMATION TO JUSTIFY CLOSURE OF THE STAFF REVIEW OF ITS GL 89-10 PROGRAM.
SOUTH TEXAS AND WATERFORD HAVE UNDERGONE GL 89-10 CLOSE-OUT INSPECTIONS AND THE STAFF IS NEARING CLOSURE OF OUR GL 89-10 REVIEW.
TMIAND MAINE YANKEE INITIALLY NOTIFIED THE STAFF THAT THEY BELIEVED THAT THEIR GL 89-10 PROGRAMS WERE COMPLETE, BUT SUBSEQUENT INSPECTIONS REVEALED THAT ADDITIONAL WORK WAS NECESSARY. THESE LICENSEES ARE SUBMITTING SCHEDULE EXTENSION JUSTIFICATIONS.
PRINCIPAL LICENSEE ACTIONS FOR CLOSURE OF STAFF REVIEW OF GL 89-10 PROGRAMS MOV DESIGN-BASIS CAPABILITY LICENSEE JUSTIFIES DESIGN-BASIS CAPABILITY FOR EACH MOV IN GL 89-10 PROGRAM AND HAS ESTABLISHED A PROCESS FOR OBTAINING FURTHER INFORMATION WHERE NOT SATISFIED WITH JUSTIFICATION FOR CERTAIN MOVs.
PRESSURE LOCKING AND THERMAL BINDING LICENSEE DEMONSTRATES PROGRESS BEING MADE TO RESOLVE CONCERN ABOUT POTENTIAL PRESSURE LOCKING AND THERMAL.
BINDING OF GATE VALVES.
PWR VALVE MISPOSITIONING PWR LICENSEE CONSIDERS VALVE MISPOSITIONING, OR COMMITS TO CONSIDER VALVE MISPOSITIONING IF STAFF DETERMINES THAT THIS RECOMMENDATION REMAINS APPROPRIATE.
PERIODIC VERIFICATION OF MOV DESIGN-BASIS CAPABILITY LICENSEE ESTABLISHES LONG-TERM PLAN FOR PERIODIC VERIFICATION THAT DEMONSTRATES THAT DEGRADATION OF DESIGN-BASIS CAPABILITY WILL BE IDENTIFIED.
EXAMPLES OF ACCEPTABLE PERIODIC VERIFICATION PLANS FOR (GL 89-10 CLOSURE ARE (1) DYNAMIC DIAGNOSTIC TESTING, OR (2) STATIC DIAGNOSTIC TESTING WITH MARGIN BASED ON PLANT-SPECIFIC DYNAMIC TESTING.
LICENSEE ACTIONS (CONTINUED)
JUSTIFICATION OF PROGRAM ASSUMPTIONS LICENSEE JUSTIFIES ASSUMPTIONS USED IN THE GL 89-10 PROGRAM, SUCH AS A. VALVE FACTOR (INCLUDING AREA ASSUMPTION)
B. STEM FRICTION COEFFICIENT C. LOAD SENSITIVE BEHAVIOR D. MARGINS FOR STEM LUBRICATION DEGRADATION AND SPRINGPACK RELAXATION E. MOTOR PERFORMANCE FACTORS (1) MOTOR RATING (2) EFFICIENCIES USED IN OPEN AND CLOSE DIRECTIONS (3)
APPLICATION FACTOR (4) POWER FACTOR USED IN DEGRADED VOLTAGE CALCULATIONS F. BASIS FOR EXTRAPOLATION METHOD OF PARTIAL D/P THRUST MEASUREMENTS G. TORQUE SWITCH REPEATABILITY H. USE OF LIMITORGUE, KALSI, OR OTHER SOURCES FOR INCREASING THRUST AND TORQUE ALLOWABLE LIMITS I.
EQUIPMENT ERROR J. POST-MAINTENANCE TESTING, ESPECIALLY VALVE PACKING ADJUSTMENTS K. GROUPING OF MOVs L. TRENDING OF MOV PROBLEMS.
LICENSEE ACTIONS (CONTINUED)
RESOLVE GL 89-10 INSPECTION FINDINGS LICENSEE RESOLVES FINDINGS FROM PREVIOUS GL 89-10 INSPECTIONS.
IN GENERAL, MOST SIGNIFICANT GL 89-10 INSPECTION CONCERNS HAVE BEEN:
(1) STATUS OF DYNAMIC TESTING; (2) TEST ACCEPTANCE CRITERIA; (3) OPERABILITY/REPORTABILITY DETERMINATIONS; (4) FEEDBACK OF TEST RESULTS; AND (5) EVALUATION OF POTENTIAL FOR PRESSURE LOCKING AND THERMAL BINDING OF GATE VALVES.
OTHER LICENSEE ACTIVITIES FOUND TO NEED IMPROVEMENT:
(1) VALIDATION OF ASSUMPTIONS IN MOV SIZING AND SETTING CALCULATIONS; (2) JUSTIFICATION OF MOV GROUPING FOR TESTING PURPOSES; (3) VERIFICATION OF EXTRAPOLATION METHODS FOR TEST DATA; (4) EVALUATION OF DIAGNOSTIC TRACE ANOMALIES; (5) INVOLVEMENT OF QA IN VERIFYING TEST DATA AND ANALYSES ACCURACY; (6) JUSTIFICATION FOR METHOD TO PERIODICALLY VERIFY DESIGN-BASIS CAPABILITY; (7) CORRECTIVE ACTION IN RESPONSE TO MOV PROBLEMS; AND (8) POST-MAINTENANCE TESTING FOLLOWING ACTIVITIES THAT MIGHT AFFECT MOV PERFORMANCE UNDER DYNAMIC CONDITIONS.
LICENSEE ACTIONS (CONTINUED)
ADDRESS CURRENT MOV ISSUES AND CONCERNS LICENSEE RECOGNIZES AND HAS PLAN TO ADDRESS CURRENT MOV ISSUES AND CONCERNS, SUCH AS ACTUAL TORQUE OUTPUT OF LIMITORQUE ACTUATORS LOWER THAN ANTICIPATED.
REDUCTION IN DC AND AC MOTOR SPEED DURING OPERATION UNDER DEGRADED VOLTAGE, DIFFERENTIAL.
PRESSURE, AND HIGH AMBIENT TEMPERATURE CONDITIONS.
ENSURING THE CAPABILITY OF MOV TO RETURN TO SAFETY POSITION FOLLOWING TESTING IF MOV IS ASSUMED TO BE OPERABLE DURING TESTING.
EVALUATION OF POTENTIAL ADVERSE EFFECTS OF MOTOR STALL AND THERMAL OVERLOAD TRIP, INCLUDING STRUCTURAL AND MOTOR DAMAGE.
CHAFING OF WIRES INSIDE LIMIT SWITCH COMPARTMENT CAN CAUSE LOSS OF FUNCTION.
GLOBE VALVE THRUST REQUIREMENTS FOR PUMPED FLOW APPARENTLY CONTROLLED BY SEAT OR GUIDE AREAS.
INDUSTRY GLOBE VALVE BLOWDOWN TESTING SHOWED SIGNIFICANTLY HIGHER THRUST REQUIREMENTS THAN PREDICTED.
INDUSTRY AND NRC-SPONSORED GATE VALVE BLOWDOWN TESTING SHOWED SOME VALVES TO HAVE UNPREDICTABLE BEHAVIOR.
CALLAWAY GL 89-10 PROGRAM GL 89-10 PROGRAM SCOPE:
150 MOVs DYNAMICALLY TESTED:
103 MOVs DESIGN-BASIS CAPABILITY OF MOVs NOT DYNAMICALLY TESTED BASED ON GROUPING WITH OTHER TESTED MOVs AT CALLAWAY AND OTHER SOURCES.
PERIODIC VERIFICATION:
MOVs STATIC TESTED USING DIAGNOSTICS EVERY 5 YEARS.
STATIC MARGIN FOR VALVE FACTOR DEGRADATION (SEPARATE AND DISTINCT FROM OTHER UNCERTAINTIES)
FOR RISING-STEM MOVs INITIALLY SET AT 25% WITH SAMPLE DYNAMIC TESTING TO JUSTIFY AT NEXT REFUELING OUTAGE.
STATIC MARGIN FOR AGE-RELATED DEGRADATION FOR QUARTER-TURN MOVs TO BE DETERMINED BASED ON SAMPLE DYNAMIC TESTING AT NEXT REFUELING OUTAGE.
DYNAMIC TESTING PERFORMED IF STATIC MARGIN FALLS BELOW ESTABLISHED CRITERIA.
PRESSURE LOCKING AND THERMAL BINDING OF GATE VALVES:
LICENSEE PERFORMED INITIAL EVALUATION OF ALL SAFETY-RELATED MOTOR-OPERATED GATE VALVES.
ADDITIONAL EVALUATION WILL BE NECESSARY.
CALLAWAY GL 89-10 PROGRAM (CONTINUED)
NRC LETTER NOTIFYING LICENSEE OF CLOSURE OF STAFF REVIEW OF CALLAWAY GL 89-10 PROGRAM FORWARDED ON JUNE 8, 1994.
LETTER INDICATES LICENSEE'S PLANS TO CONDUCT THE FOLLOWING ACTIVITIES TO ENSURE THAT ASSUMPTIONS USED IN VERIFYING GL 89-10 MOV DESIGN-BASIS CAPABILITIES REMAIN VALID:
- 1. EVALUATE JUSTIFICATION FOR DESIGN-BASIS CAPABILITY OF 18 MOVs AS ADDITIONAL INDUSTRY INFORMATION BECOMES AVAILABLE.
- 2. CONTINUE TO ASSESS USE OF LINEAR EXTRAPOLATION OF MOV PERFORMANCE DATA.
- 3. CONTINUE TO EVALUATE PRESSURE LOCKING AND THERMAL BINDING OF GATE VALVES.
- 4. PERFORM PERIODIC MOV PERFORMANCE VERIFICATION BY DYNAMIC TESTING GATE AND GLOBE MOVs WHEN MARGIN IS LESS THAN 25 PERCENT AFTER REQUIRED THRUST ADJUSTED FOR UNCERTAINTIES. FOLLOWING NEXT REFUELING OUTAGE, PROVIDE STAFF WITH DYNAMIC TEST-BASED INFORMATION CONFIRMING 25% STATIC MARGIN FOR GATE AND GLOBE VALVES AND ESTABLISHING MARGIN FOR AGE-RELATED DEGRADATION FOR BUTTERFLY VALVES.
FORT CALHOUN GENERIC LETTER 89-10 PROGRAM GL 89-10 PROGRAM SCOPE:
29 MOVs DYNAMICALLY TESTED:
20 MOVs DESIGN-BASIS CAPABILITY OF MOVs NOT DYNAMICALLY TESTED BASED ON GROUPING WITH OTHER TESTED MOVs AT FORT CALHOUN AND OTHER SOURCES.
PERIODIC VERIFICATION:
INSPECTION REPORT 94-05 STATES THAT LICENSEE'S PLAN FOR PERIODIC VERIFICATION INCLUDES DYNAMIC TESTING.
PRESSURE LOCKING AND THERMAL BINDING OF GATE VALVES:
LICENSEE EVALUATED GL 89-10 MOVs AND FOUND NONE SUSCEPTIBLE TO PRESSURE LOCKING. ADDITIONAL EVALUATION WILL BE NECESSARY.
LICENSEE PREPARING SUBMITTAL TO SUPPORT CLOSURE OF STAFF REVIEW OF FORT CALHOUN GL 89-10 PROGRAM
WATERFORD GENERIC LETTER 89-10 PROGRAM GL 89-10 PROGRAM SCOPE:
56 MOVs DYNAMICALLY TESTED:
44 MOVs DESIGN-BASIS CAPABILITY OF MOVs NOT DYNAMICALLY TESTED BASED ON GROUPING WITH OTHER TESTED MOVs AT WATERFORD AND OTHER SOURCES.
PERIODIC VERIFICATION:
MOVs STATIC TESTED USING DIAGNOSTICS EVERY 5 YEARS.
STATIC MARGIN FOR VALVE FACTOR DEGRADATION (SEPARATE AND DISTINCT FROM OTHER UNCERTAINTIES)
FOR GATE MOVs INITIALLY SET AT 25% WITH SAMPLE DYNAMIC TESTING TO JUSTIFY AT NEXT REFUELING OUTAGE.
DYNAMIC TESTING PERFORMED IF STATIC MARGIN FALLS BELOW ESTABLISHED CRITERIA.
LICENSEE PREPARING RESPONSE TO CLOSE-OUT INSPECTION REPORT ON PERIODIC VERIFICATION (INCLUDING GLOBE AND BUTTERFLY VALVES) AND POST MAINTENANCE TESTING.
PRESSURE LOCKING AND THERMAL BINDING OF GATE VALVES:
LICENSEE DETERMINED THAT 8 GATE VALVES WERE POTENTIAL SUSCEPTIBLE TO PRESSURE LOCKING AND EVALUATED THEIR CAPABILITY TO OVERCOME THIS CONDITION. STAFF DID NOT REVIEW CALCULATIONS FOR TECHNICAL MERIT. LICENSEE PERFORMED PRELIMINARY EVALUATION OF THERMAL BINDING.
ADDITIONAL EVALUATIQN WILL BE NECESSARY.
PERIODIC VERIFICATION OF MOV DESIGN-BASIS CAPABILITY FOR GL 89-10 CLOSURE, LICENSEES ARE EXPECTED TO HAVE A LONG-TERM PLAN FOR PERIODIC VERIFICATION THAT DEMONSTRATES THAT DEGRADATION OF MOV DESIGN-BASIS CAPABILITY WILL BE IDENTIFIED.
LICENSEES MAY USE PRA CONSIDERATIONS TO PRIORITIZE MOVs IN ESTABLISHING PERIODIC VERIFICATION FREQUENCY.
LICENSEES MUST HAVE CONFIDENCE THAT SAFETY-RELATED MOVs WILL REMAIN OPERABLE UNTIL NEXT SCHEDULED DESIGN-BASIS VERIFICATION TEST.
NRC STAFF IS WORKING WITH THE OPERATIONS AND MAINTENANCE COMMITTEE OF THE ASME BOILER AND PRESSURE VESSEL CODE TO DEVELOP ACCEPTABLE METHODS TO VERIFY MOV DESIGN-BASIS CAPABILITY THROUGH PERIODIC TESTING.
EXAMPLES OF ACCEPTED PERIODIC VERIFICATION PLANS FOR GL 89-10 CLOSURE ARE (1)
DYNAMIC DIAGNOSTIC TESTING, OR (2) STATIC DIAGNOSTIC TESTING WITH MARGIN BASED ON PLANT-SPECIFIC DYNAMIC TESTING.
AFTER CLOSURE OF THE STAFF'S REVIEW OF GL 89-10 PROGRAMS, LICENSEES MAY ADJUST THEIR COMMITMENTS TO PERIODIC VERIFICATION OF MOV DESIGN-BASIS CAPABILITY WITH ADEQUATE JUSTIFICATION.
1989-93 Region 2 MOV Reportable Events Motor Operator Failures Year Total U 1993 12 1989....................
LI 1992 10'9
- 1.
H 1991.
'90'92 U01990 ca El 1989 m 6 4
2 0
Region 2 Licensees by Unit 17 Units had no reportable failures during this period
1989-93 National MOV Reportable. Events Motor Operator Failures
- 30.
20 co 10.1 1989....
199 191.99.19 Year I..
ejo 2.....
e.o,3 4,
1989-94 Region 2 MOV Reportable Events Motor Design, Const, Fab, or Installation Errors El Total U 1994
'90
- 1993 10 L1992
'91 91991 m 1990 6 8 0D1989 4
'94 2
Fqgiop 2 Licepspes by Unit 22 Units had no reportab e events over this period
1989-94 National MOV Reportable Events Valve Failures Requiring Repair 250 200 o 150 0
1989 1990 1991 1992 1993 1994 Ye ar LiRegion 2 U Regions 1,3,4,5
1989-94 Region 2 MOV Reportable Events Valve Failures Due to Design, Fab, or Installation errors
[Total 25 U 1994 1993 8
- > 1989
,20 01992
- 7.
'91 119901
.. 10 019893
>24 w3 2
1
.0 Region 2 Licensees by Unit 7 Uinits had no reported valve failures during this period
1989-94 National MOV Reportable Events Valve Failures due to Design, Const, Fab or Installation Errors 100 80 0
1989 1990 1991 1992 1993 1994 Year D Region 2 U Regions 1,3,4,5
1989-94 National MOV Reportable Events Motor Design, Const, Fab or Installation Failures 25 20' u-10 5
01989 1990 1991 1992 1993 1994 Year L Region 2 U Regions 1,3,4,5