Text

ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

W

ESSION NBR:9404120135

DOC.DATE: 94/03/29

NOTARIZED: NO

DOCKET #

FACIL:50-261 H.B. Robinson Plant, Unit 2, Carolina Power & Light C 05000261

AUTH.NAME

AUTHOR AFFILIATION

CHRISTENSEN,H.

Region 2 (Post 820201)

RECIP.NAME

RECIPIENT AFFILIATION

HINNANT,C.S.

Carolina Power & Light Co.

R

SUBJECT: Ack receipt of 940321 response to notice of violation from

insp rept 50-261/94-03.

DISTRIBUTION CODE: IE01D

COPIES RECEIVED:LTR

_ ENCL C2 SIZE:

D

TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response

S

NOTES:

RECIPIENT

COPIES

RECIPIENT

COPIES

ID CODE/NAME

LTTR ENCL

ID CODE/NAME

LTTR ENCL

A

PD2-1 PD

1

MOZAFARI,B

1

D

INTERNAL: AEOD/DEIB

1

AEOD/DSP/ROAB

1

AEOD/DSP/TPAB

1

AEOD/TTC

1

D

DEDRO

1

NRR/DORS/OEAB

1

NRR/DRCH/HHFB

1

NRR/DRIL/RPEB

1

S

NRR/DRSS/PEPB

1

NRR/PMAS/ILPB1

1

NRR/PMAS/ILPB2

1

NUDOCS-ABSTRACT

1

OE DIR

1

OGC/HDS2

1

__

02

1

.

RES/HFB

1

RGN2

FILE

01

1

E

RNAL: EG&G/BRYCE,J.H.

1

NRC PDR

1

NSIC

1

R

I

D

S

A

D

D

NOTE TO ALL "RIDS" RECIPIENTS:

S

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK,

ROOM P1-37 (EXT. 20079) TO ELIMINATE YOUR NAME FROM DISTRIBUTION

LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR

22

ENCL

-17

MAR 2 9 1994

Docket No.:

50-261

License No.:

DPR-23

Carolina Power and Light Company

ATTN:

Mr. C. S. Hinnant

Vice President

H. B. Robinson Steam Electric Plant

Unit 2

P. 0. Box 790

Hartsville, SC 29550-0790

Gentlemen:

SUBJECT:

REPORT NO. 50-261/94-03

Thank you for your response of March 21, 1994, to our Notice of Violation

issued on February 18, 1994, concerning activities conducted at your H. B.

Robinson facility. We have evaluated your response and found that it meets

the requirements of 10 CFR 2.201.

We will examine the implementation of your

corrective actions during future inspections.

.

We appreciate your cooperation in this matter.

Sincerely,

Harold

. Chris ensen, Acting Chief

Reactor Projects Branch 1

Division of Reactor Projects

cc: M. P. Pearson

Plant Manager

H. B. Robinson Steam Electric Plant

P. 0. Box 790

Hartsville, SC

29550-0790

H. W. Habermeyer, Jr.

Vice President

Nuclear Services Department

Carolina Power & Light Company

P. 0. Box 1551

- Mail 0HS7

Raleigh, NC 27602

(cc cont'd - See page 2)

9404120135 940329

PDR ADOCK 05000261

PDR

Carolina Power and Light Company

2

(cc cont'd)

R. Krich, Manager

Regulatory Compliance

H. B. Robinson Steam Electric Plant

P. 0. Box 790

Hartsville, SC 29550

Max Batavia, Chief

Bureau of Radiological Health

Dept. of Health and Environmental

Control

2600 Bull Street

Columbia, SC

29201

Dayne H. Brown, Director

Division of Radiation Protection

N. C. Department of Environment,

Commerce & Natural Resources

P. 0. Box 27687

Raleigh, NC

27611-7687

H. Ray Starling

Manager -

Legal Department

Carolina Power and Light Co.

P. 0. Box 1551

Raleigh, NC

27602

Karen E. Long

Assistant Attorney General

State of North Carolina

P. 0. Box 629

Raleigh, NC 27602

Robert P. Gruber

Executive Director

Public Staff - NCUC

P. 0. Box 29520

Raleigh, NC

27626-0520

Public Service Commission

State of South Carolina

P. 0. Box 11649

Columbia, SC 29211

bcc:

(See page 3)

MAR 2 9 1994

Carolina Power and Light Company

3

bcc: H. Christensen, RH

B. Mozafari, NRR

Document Control Desk

NRC Resident Inspector

U. S. Nuclear Regulatory Commission

Route 5, Box 413

Hartsville, SC 29550

  • RII:DRP

RII:DR

JStare s:tj

WOrders

03/19/94

03/

/9