Amend 66 to License DPR-23,allowing Dilution of Liquid Radwaste Using Unit 1 Circulation Pumps When Unit 2 Pumps Inoperable
ML14175A705
Person / Time
Site: Robinson 
Issue date: 03/17/1982
From: Varga S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML14175A706 List:
References
DPR-23-A-066 NUDOCS 8203310015
Download: ML14175A705 (5)


Text

SREG at UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 CAROLINA POWER AND LIGHT COMPANY DOCKET NO. 50-261 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 66 License No. DPR-23

1. The Nuclear Regulatory Commission (the Commission) has found that:

A. The application for amendment by Carolina Power and Light Company (the licensee) dated January 28, 1982, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C. There.is reasonable assurance Ci) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and Cii) that such activities will be conducted in compliance with the Commission's regulations; D. The issuance of this amendment will not be inimical to th.e common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

6203310015 820317 PDR ADOCK 05000261 P

PDR

-2

2. Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 3.B of Facility Operating License No. DPR-23 is hereby amended to read as follows:

(B) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 66, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Speci fi cations.

3. This license amendment is effective as of the date of its issuance.

FO HE NUCLEAR RE LATORY COMMISSION v ven A.

, Chief Operating Reactors Bra c

  1. 1 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: Marhc 17, 1982

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 66 TO FACILITY OPERATING LICENSE NO. DPR-23 DOCKET NO.

50-261 Revise Appendix A as follows:

Remove Pages Insert Pages 3.9-2 3.9-2 3.9-3 3.9-3

b. Measuring the activities of specific radionuclides in the discharge and adding to the equilibrium activity in Lake Robinson.

3.9.1.2 The concentration of radioactive liquid effluents when averaged over a period of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> shall not exceed 10 times the value permitted by 3.9.1.1 above.

3.9.1.3 Prior to release of liquid waste, a sample shall be taken, and analyzed for beta-gamma activity and tritium activity to demonstrate compliance with 3.9.1.1 and 3.9.1.2 above.

3.9.1.4 During release of liquid radioactive wastes, the following conditions shall be met:

a. A least one condenser circulating water pump shall be in operation. The Unit #2 circulating pumps shall be used when available. When the Unit #2 circulating water system is out-of service, the Unit #1 circulating pumps shall be employed.
b. The gross activity monitor in the discharge in the discharge shall be operable.

3.9.2 Gaseous Wastes 3.9.2 The annual average release rates of gaseous wastes shall be limited as follows:

Z

< 5.0 x 10 (m /sec) where Qi is the annual release rate (Ci/sec) of any radioisotope, 1, and (MPC)i in units of uCi/cc are defined in Column 1, Table II of Appendix B to 10 CFR 20', except that for isotopes of iodine and particulates with half lives greater than 8 days, the values of (MPC)i shall be reduced by a factor of 1/700.

3.9.2.2 The maximum averaged release rate over 15 minutes shall not exceed ten times the yearly average limit of 3.9.2.1.

3.9-2 Amendment No. 66

3.9.2.3 Prior to release of gaseous wastes, the contents of the gas holdup tank shall be sampled and analyzed for radioactivity to determine compliance with 3.9.2.1 and 3.9.2.2 above.

3.9.2.4 During release of gaseous wastes to the plant vent, the following conditions shall be met:

a. At least one auxiliary building exhaust fan shall be in operation.
b. The plant vent activity monitor shall be operable during discharges, or the containment and plant vent monitor shall be sampling from the stack.

3.9.2.5 During power operation, whenever the air ejector discharge monitor is inoperable, gas discharge from the air ejector will be routed to the plant vent for monitoring.

Basis Liquid wastes from the Radioactive Waste Disposal System are diluted in the Circulating Water System discharge, and then released to the lake via the discharge canal.()

With the three Unit #2 circulating pumps operating, the rated capacity of the Circulating Water System is 482,000 gpm.

With both Unit #1 circulating pumps operating, their flow to the discharge canal will be 87,000 gpm.

The actual circulating water flow under various operating conditions will be calculated from the head differential across the pumps and the manufacturer's head capacity curves. Because of the low radio-activity levels in the circulating water discharge, the concentration of liquid radio active effluents at this point cannot be measured directly. The concentrations in the circulating water discharge will be calculated from the measured concentration in the Waste Condensate Tank, the flow rate of the Waste Condensate Tank, the flow rate of the Waste Condensate Pumps, and the flow in the Circulating Water System.

To this released contentration-it is necessary

-to add the concentration of radionuclides in the Circulating Water. This concentration is significant because the circulating water flow is usually greater than the flow through Lake Robinson. The method of calculating the equilibrium concentration of radinuclides in Lake Robinson will be as detailed in the FSAR.(2) 3.9-3 Amendment No. 66