June 20, 1979 John F. Wolf, Esq., Chairman Dr. Richard F. Cole 3409 Shepherd Street Atomic Safety and Licensing Board Chevy Chase, Maryland 20015 U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. A. Dixon Callihan Union Carbide Corporation P. 0. Box Y Oak Ridge, Tennessee 37830 In the Matter of Carolina Power-and Light-Company (H. B. Robinson, Unit No. 2)

Docket Nos. 50-261 (OL Modification)

Gentlemen:

The enclosed staff memoranda dated May 25, 1979, and May 26, 1979, regarding cracking of feedwater lines at D.C..Cook are being sent to this Board and the parties for their information.

Sincerely, Edward S. Christenbury Director & Chief Counsel Hearing Division

Enclosure:

Memorandum fm. Victor Stello to Edward Christenbury dtd INTERNAL Dist:

June 8, 1979, with attachments NRC Central FF (2) cc: George F. Trowbridge, Esq.

Shapar/Engelhardt Richard Jones, Esq.

SLewis Atomic Safety and Licensing Board Panel DNeighbors Atomic Safety and Licensing Alppeal Board Panel SBajwa Docketing and Service Section Chron WPaton C o wns 318 (9.

N 02*

S OR........

.R

.N.

OFF..E...9.......709 X=C FORM 318 (9-76) NRCM 0240 U.S. GOVERNuMENT PRNTING OFFICE:

S978

- 265

  • 769