MONTHYEARML12171A0532012-06-13013 June 2012 Commitments Related to Updated Hydrologic Analysis Results Project stage: Request ML12171A6212012-06-19019 June 2012 Waste Confidence Secy Order - Order of Acting Secretary to the Parties Inviting Answers to Suspend Final Licensing Decisions by 12 PM Edt, Monday, June 25, 2012 Project stage: Request ML12237A2712012-08-28028 August 2012 Acceptance of Requested Licensing Action Regarding Application to Revise Watts Bar Nuclear Plant Unit 1 Updated Final Safety Analysis Report Regarding Changes to Hydrologic Analysis Project stage: Acceptance Review ML13044A5612013-03-0101 March 2013 Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Re Flooding Hazard Reevaluation for Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident Project stage: RAI ML13046A1122013-03-0101 March 2013 Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis Project stage: RAI ML13067A3932013-03-0101 March 2013 Supplement to Application to Revise Watts Bar Nuclear Plant Unit 1 Updated Final Safety Analysis Report Regarding Changes to Hydrologic Analysis (WBN-UFSAR-12-01) Project stage: Supplement ML13126A2952013-04-30030 April 2013 Response to NRC Health Physics and Human Performance Branch Request for Additional Information Related to License Amendment Request for Watts Bar Nuclear Plant (WBN) Unit 1 Updated Final Safety Analysis Report Changes Associated with Hydrol Project stage: Request ML13123A1632013-04-30030 April 2013 Tennessee Valley Authority - Additional Information Regarding March 28, 2013, Public Meeting with NRC Regarding the Commercial Grade Dedication Recovery Project Project stage: Meeting ML13127A1682013-05-14014 May 2013 Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis from Balance of Plant Branch Project stage: RAI ML13168A4102013-06-13013 June 2013 Response to NRC Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis Project stage: Response to RAI ML13276A2842013-08-15015 August 2013 E-mail - Request for RAI Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis Project stage: RAI ML13231A0822013-08-16016 August 2013 NRR E-mail Capture - Watts Bar, Unit 1 - RAI License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis Project stage: RAI CNL-13-112, Response to NRC Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis from Mechanical and Civil Engineering Branch2013-10-21021 October 2013 Response to NRC Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis from Mechanical and Civil Engineering Branch Project stage: Response to RAI CNL-13-147, Supplemental Response to NRC Health Physics & Human Performance Branch Request for Additional Information Related to License Amendment Request for Watts Bar Unit 1, Updated Final Safety Analysis Report Changes Associated with Hydrologic A2013-12-18018 December 2013 Supplemental Response to NRC Health Physics & Human Performance Branch Request for Additional Information Related to License Amendment Request for Watts Bar Unit 1, Updated Final Safety Analysis Report Changes Associated with Hydrologic Ana Project stage: Supplement CNL-14-004, Response to an NRC Verbal Request for Additional Information Related to the License Amendment Request to Updated Final Safety Analysis Report Changes Associated with the Hydrologic Analysis2014-01-17017 January 2014 Response to an NRC Verbal Request for Additional Information Related to the License Amendment Request to Updated Final Safety Analysis Report Changes Associated with the Hydrologic Analysis Project stage: Request ML14080A3352014-03-21021 March 2014 Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis Project stage: RAI ML14129A3162014-05-0909 May 2014 E-mail Re. RAI Related to LAR to Updated FSAR Changes Associated with Hydrologic Analysis from Mechanical and Civil Engineering Branch - Dam Stability Safety Factor Project stage: RAI ML14149A2172014-05-21021 May 2014 E-mail Re. WBN 1 Hydrology LAR with UFSAR Changes Project stage: Approval ML14322B0182014-11-18018 November 2014 E-mail Re. Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis Project stage: RAI CNL-14-228, Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis2014-12-0505 December 2014 Request for Additional Information Related to License Amendment Request to Updated Final Safety Analysis Report Changes Associated with Hydrologic Analysis Project stage: Request ML15005A3142015-01-28028 January 2015 Nuclear Plant, Unit 1 - Issuance of Amendment to Revise Updated Final Safety Analysis Report Regarding Changes to Hydrology Analysis Project stage: Approval 2013-06-13
[Table View] |
Text
From:
Sent:
To:
Cc:
Subject:
Dear Mr. Shea:
Hon, Andrew Friday, May 09, 2014 11:26 AM
'Shea, Joseph W'; 'Schrull, Edward Dustin' McMurtray, Anthony; Quichocho, Jessie; Poole, Justin; Lingam, Siva; Hoang, Dan Watts Bar Nuclear Station, Unit 1 -RAI Related To LAR To Updated FSAR Changes Associated With Hydrologic Analysis From Mechanical And Civil Engi1.~ering Branch -
Dam Stability Safety Factor (TAC NO. ME913 By letter dated July 19, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML122360173), the Tennessee Valley Authority (TVA), submitted a license amendment request to revise the Watts Bar Nuclear Plant (WBN), Unit 1 Updated Final Safety Analysis Report (UFSAR) to reflect the results from new hydrologic analysis. The proposed changes in the updated hydrologic analysis include updated input information, and updates to methodology that include the use of the U.S. Army Corps of Engineers Hydrologic Modeling System and River Analysis System software. By a letter dated March 1, 2013 (ADAMS Accession No. ML13067A393), TVA supplemented the submittal with additional information. In order to complete its review of the above documents, the U.S. Nuclear Regulatory Commission staff requests the following additional information TVA seeks approval to revise the WBN 1 Updated Safety Analysis Report (UFSAR) to adopt a revised hydrologic analysis for the WBN 1 site. In support of this revised analysis, TVA requested NRC approval of changes to several sections of the UFSAR. Under Enclosure 1, "Evaluation of Proposed Changes,", "Proposed WBN Unit 1 UFSAR Text Changes (Markups)," Section 2.4.3.4, "Probable Maximum Flood Flow," under the "Concrete Section Analysis," page 2.4-22, TVA proposed to change the UFSAR as follows: "For concrete dam sections, factors of safety in sliding were determined by comparison of the existing design headwater/tailwater levels to the headwater/tailwater levels that would occur in the PMF as described in Section 2.4.3. The structures were considered safe against failure if a factor of safety greater than 1.0 for sliding was demonstrated. The dams upstream of Watts Bar Nuclear Plant passed this test."
The current UFSAR, Section 2.4.3.4, "Probable Maximum Flood Flow," under the "Concrete Section Analysis,"
reads as follows: "For concrete dam sections, comparisons were made between the original design headwater and tailwater levels and those that would prevail in the PM F. If the overturning moment and horizontal forces were not increased by more than 20%, the structures were considered safe against failure. All upstream dams passed this test except Douglas, Fort Loudoun, and Watts Bar. Original designs showed the spillway sections of these dams to be most vulnerable. These spillway sections were examined in further detail and judged to be stable."
This change appeared to be a change to the current licensing bases. However, in information provided to the NRC for review and audit, TVA did not provide a technical basis to support the changes to Section 2.4.3.4, "Probable Maximum Flood Flow," under the "Concrete Section Analysis." Please provide information, including any analysis and calculations, or reference to industry standards (e.g. FERC, Army Corp of Engineers, and TVA River Operations), that supports the UFSAR change, that using a factor of safety greater than 1.0, for sliding, provides an adequate basis that dam structures are considered safe against failure. If the proposed factor of safety for the UFSAR change is less than the current criteria used for evaluating dam stability by TVA River Operations, please explain the rationale for the difference in criteria being used.
1
The proposed questions were discussed with your staff on May 9 2014. Your staff confirmed that these questions did not include proprietary or security-related information and agreed to provide a response by May 30, 2014. The NRC staff considers that timely responses to RAis help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me.
ADAMS Accession No. ML14129A316 AndyHon, PE Project Manager (Watts Bar Nuclear Unit-1)
Plant Licensing Branch 1/-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation 301-415-8480 OWFN08E5 Mail Stop 08G-9a andrew. hon@ nrc. qov 2