IMMEDIATE PRELIMINARY NOTIFICATION June 18, 1979 PRELIMINARY NOTIFICATION OF AN EVENT OR UNUSUAL OCCURRENCE --

PNO-79-67AT This preliminary notification provides updated information of safety or public interest significance..

Facility: Three Mile Island Unit 2 Hiddletown, Pennsylvania (DN-50-320) subject:

NUCLFAR INCIDENT AT THREE MILE ISLAND operational:

1.

The average coolant temperature is -155 degrees F and the highest incore thermocouple temperature reading is 273 degrees F. Core cooling is being maintained by natural circulation. Pressure is about 350 psi with the pressurizer in solid operation. Steam is being admitted to the main con denser through the turbine bypass valve from the A Steam Generator.

2.

Reactor building water level is being measured daily, and is now 7.0 +/-

0.5 feet above floor level.

This lower than previously reported level is due to refinement of the measurement technique, and does not reflect an acutal level decrease.

3.

Preoperational testing for the Spent Fuel Pool Taak Farm, Once-Through Steam Generator "B" Long-Term Cooling System, the modified;radwaste treatment syste (EPICOR), and the pressure/volume control system pro gressed slowly during the past week due to various operational/procurement problems encountered. The testing may be completed within the next two weeks.

Environmental Status:

Environmental radiation levels remain consistent with natural background levels. Airborne releases have been below Technical Specification limits.

From June 11-17, 42 air samples, 2 milk samples, 4 vegetation samples and 2 soil samples were collected by the NRC. All analytical results were less than MDA. EPA air, water and milk samples collected during the week (up to June 15) showed no detectable activity from THI.

CONTINUED 7906270027 I.I

Continued June 18 1979 Page 2 PNO-79-67AT

Contact:

RCPaulus, IE X27246 DThompson, 1B X28487 Distribution:

Transmitted H St Chairman Rendrie Commissioner Bradford S. J. Chilk, SECY Commissioner Kennedy Commissioner Ahearne C. C. Kammerer, CA Commissioner Gilinsky ACRS (For Distribution)

Transmitted: HNBB P. Bld3 ^..o V. Stello, IE L. V. Gossick, EDO H. R. Denton, NRR Region I C &

1. L, Orustein, EDO R. C. DeYoung, NRR Region II J. J. Fouchard, PA R. J. Mattson, NRR Region IMl g if N. M. Haller, MPA R. S. Boyd, NRR Region IV At I4p R. G. Ryan, OSP SS Bldg %..1.

Region V :'<Lo i

H. Y. Shapar, ELD W. J. Dircks, NMSS (MAIL)

S. Levine, RES J. J. Cummings, OIA R. Minogue, SD IE (TMI) Site (Provide copy to STATE)

White House Situation Room FDAA (Provide copies to the Administrator and the Operations Center)

EPA DOE/EOC PEMA BRP (State of PA)

DCPA Handcarry (FAA)

IMMEDIATE PRELIMINARY NOTIFICATION Z