1 NRR-PMDAPEm Resource From:
Bamford, Peter Sent:
Monday, March 24, 2014 2:01 PM To:
PYLE, STEPHENIE L (SPYLE@entergy.com)
Cc:
nmosher@entergy.com; mhall10@entergy.com; Kuntz, Robert; Miller, Ed
Subject:
RAI Regarding Recommendation 2.1 Flood Hazard Reevaluation Extension Request Attachments:
ANO RAI.docx Stephenie, please see the attached request for additional information regarding the subject incoming letter dated March 12, 2014. After you have had a chance to review this request, please contact me so that I can provide you with any clarification on the question that you may require and so that we can discuss a due date for your response. At that time, I should be able to provide you with a reference ADAMS Accession Number for this email that you can use in your response. Also, I request that you include a restatement of the attached question when you provide your docketed response.
Thank you.
Peter Bamford NRR/DORL/LPL4-1 Diablo Canyon and ANO Project Manager 301-415-2833
Hearing Identifier:
NRR_PMDA Email Number:
1185 Mail Envelope Properties (Peter.Bamford@nrc.gov20140324140000)
Subject:
RAI Regarding Recommendation 2.1 Flood Hazard Reevaluation Extension Request Sent Date:
3/24/2014 2:00:34 PM Received Date:
3/24/2014 2:00:00 PM From:
Bamford, Peter Created By:
Peter.Bamford@nrc.gov Recipients:
"nmosher@entergy.com" <nmosher@entergy.com>
Tracking Status: None "mhall10@entergy.com" <mhall10@entergy.com>
Tracking Status: None "Kuntz, Robert" <Robert.Kuntz@nrc.gov>
Tracking Status: None "Miller, Ed" <Ed.Miller@nrc.gov>
Tracking Status: None "PYLE, STEPHENIE L (SPYLE@entergy.com)" <SPYLE@entergy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 707 3/24/2014 2:00:00 PM ANO RAI.docx 27594 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
REQUEST FOR ADDITIONAL INFORMATION ARKANSAS NUCLEAR ONE, UNITS 1 AND 2 PROPOSED EXTENSION REQUEST REGARDING RESPONSE 2 TO MARCH 12, 2012, REQUEST FOR INFORMATION, ENCLOSURE 2, RECOMMENDATION 2.1, FLOOD HAZARD REEVALUATION REPORT DOCKET NOS. 50-313 AND 50-368 By letter dated March 12, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12053A340), the U.S. Nuclear Regulatory Commission (NRC) issued a request for information pursuant to Title 10 of the Code of Federal Regulations Section 50.54(f), regarding, in part, a flooding hazard revaluation report for Arkansas Nuclear One, Units 1 and 2 (ANO). In that letter, the required response schedule for the report was specified to be in accordance with the NRCs prioritization plan, which corresponds to March 12, 2014, for ANO. By letter dated June 8, 2012 (ADAMS Accession No. ML12164A567), Entergy Operations, Inc.
(Entergy, the licensee) committed to submit the flood hazard reevaluation for ANO by March 12, 2014. By letter dated March 12, 2014 (ADAMS Accession No. ML14071A459), Entergy requested an extension for the completion of the report based on the schedule to receive input information from the U.S. Army Corps of Engineers (USACE). In Entergys letter dated March 12, 2014, the licensee requested an extension for submission of the flood hazard reevaluation report to a date six months after the USACE information is received by the licensee. In order for the NRC staff to complete its review of the extension request, a response to the following request for additional information is requested.
1.) The NRC staff requests that Entergy provide a more detailed breakdown of the activities and analyses that remain to be conducted, as well as the associated schedule for those activities and analyses. The NRC staff suggests that a Gantt chart or similar format would be an effective means of communicating the schedule information.