NRC RAI (TAC NOS. MF1117 and MF1118)

ATTACHMENT RAI 4 -1 Spreadsheet Files Sheet 1 of 3 Water Depth Elevation vs. Flow Rate for H-Q Curve Generation Sections with ending and starting station elevations > 220, as grayed out, are not calculated BLOCK HQ Cw =

2.6215 1

2 3

4 5

6 7

8 9

10 11 Location ID dL l B U/S Crest Elev Avg. U/S Crest Elev D/S Crest Elev Avg. D/S Crest Elev HW Q

HW, ft dQ, cfs HW, ft dQ, cfs HW, ft dQ, cfs HW, ft dQ, cfs 09+37.17 New (Q twd E) 73.24 217.51 218.13 219.20 219.76 1

219.76 0.00 219.97 18.31 220.09 36.62 220.20 54.93 220.29 73.24 12+46.01 New (Q twd E) 308.84 218.07 217.79 218.39 218.80 2

218.80 0.00 219.00 77.21 219.13 154.42 219.24 231.63 219.33 308.84 12+60.44 New (Q twd E) 14.43 218.43 218.25 218.38 218.39 3

218.39 0.00 218.61 3.61 218.74 7.22 218.86 10.82 218.96 14.43 12+76.14 New (Q twd E) 15.70 218.34 218.39 218.38 218.38 4

218.39 0.00 218.62 3.93 218.76 7.85 218.88 11.78 218.99 15.70 13+76.70 New (Q twd E) 100.56 218.09 218.22 218.64 218.51 5

218.51 0.00 218.72 25.14 218.86 50.28 218.97 75.42 219.07 100.56 13+91.66 New (Q twd E) 14.96 218.12 218.11 218.67 218.66 6

218.66 0.00 218.87 3.74 218.99 7.48 219.10 11.22 219.20 14.96 14+06.64 New (Q twd E) 14.98 218.10 218.11 218.62 218.65 7

218.65 0.00 218.86 3.75 218.98 7.49 219.09 11.24 219.19 14.98 15+57.30 New (Q twd E) 150.66 217.59 217.85 218.89 218.76 8

218.76 0.00 218.96 37.67 219.09 75.33 219.20 113.00 219.29 150.66 15+70.40 New (Q twd E) 13.10 217.59 217.59 218.92 218.91 9

218.91 0.00 219.11 3.28 219.24 6.55 219.34 9.83 219.44 13.10 15+81.55 New (Q twd E) 11.15 217.66 217.63 218.94 218.93 10 218.93 0.00 219.14 2.79 219.26 5.57 219.37 8.36 219.46 11.15 16+41.28 New (Q twd E) 59.73 218.83 218.25 219.18 219.06 11 219.06 0.00 219.27 14.93 219.40 29.87 219.50 44.80 219.60 59.73 16+55.65 New (Q twd E) 14.37 218.71 218.77 219.13 219.16 12 219.16 0.00 219.37 3.59 219.50 7.19 219.61 10.78 219.71 14.37 16+67.86 New (Q twd E) 12.21 218.81 218.76 219.28 219.21 13 219.21 0.00 219.42 3.05 219.55 6.10 219.65 9.16 219.75 12.21 17+88.18 New (Q twd E) 120.32 218.99 218.90 219.40 219.34 14 219.34 0.00 219.55 30.08 219.68 60.16 219.79 90.24 219.89 120.32 18+23.81 New (Q twd E) 35.63 220.29 219.64 220.46 219.93 15 219.93 0.00 220.14 8.91 220.28 17.81 220.39 26.72 220.49 35.63 18+92.77 New (Q twd E) 20.09 219.70 219.95 219.50 219.81 16 219.95 0.00 220.16 5.02 220.28 10.05 220.38 15.07 220.48 20.09 20+43.03 New (Q twd E) 150.26 217.65 218.68 218.44 218.97 17 218.97 0.00 219.18 37.57 219.32 75.13 219.43 112.70 219.53 150.26 20+55.06 New (Q twd E) 12.03 217.88 217.77 218.38 218.41 18 218.41 0.00 218.62 3.01 218.75 6.01 218.85 9.02 218.95 12.03 20+72.01 New (Q twd E) 16.95 218.21 218.05 218.50 218.44 19 218.44 0.00 218.65 4.24 218.78 8.48 218.89 12.71 218.99 16.95 21+00.65 New (Q twd E) 28.64 218.88 218.55 218.87 218.69 20 218.69 0.00 218.90 7.16 219.04 14.32 219.16 21.48 219.26 28.64 21+31.14 New (Q twd E) 30.49 220.62 219.75 220.45 219.66 21 219.75 0.00 219.96 7.62 220.08 15.24 220.20 22.87 220.30 30.49 22+75.60 Existing 88.52 217.90 218.45 217.32 218.16 22 218.45 0.00 218.65 22.13 218.78 44.26 218.88 66.39 218.97 88.52 New Station 24+77.07 Existing 201.47 217.98 217.94 217.60 217.46 23 217.94 0.00 218.15 50.37 218.27 100.74 218.37 151.10 218.47 201.47 24+99.27 New 22.20 217.63 217.81 218.20 217.90 24 217.90 0.00 218.12 5.55 218.26 11.10 218.38 16.65 218.48 22.20 28+62.60 New 363.33 218.69 218.16 219.46 218.83 25 218.83 0.00 219.04 90.83 219.17 181.67 219.27 272.50 219.37 363.33 Ped Opening B 29+27.00 New 64.40 217.51 218.10 218.27 218.87 26 218.87 0.00 219.08 16.10 219.20 32.20 219.31 48.30 219.40 64.40 Ped Opening B 29+32.00 Existing 5.00 217.63 217.78 27 217.78 0.00 218.00 1.25 218.13 2.50 218.25 3.75 218.35 5.00 TEST 29+55.16 Existing 23.16 217.75 217.75 217.29 217.29 28 217.75 0.00 217.96 5.79 218.08 11.58 218.18 17.37 218.28 23.16 30+14.38 Existing 59.22 219.47 218.61 218.83 218.06 29 218.61 0.00 218.82 14.81 218.94 29.61 219.04 44.42 219.14 59.22 30+69.35 Existing 54.97 219.34 219.41 218.72 218.78 30 219.41 0.00 219.61 13.74 219.74 27.48 219.84 41.23 219.93 54.97 31+42.68 Existing 73.33 218.27 218.81 217.76 218.24 31 218.81 0.00 219.01 18.33 219.14 36.67 219.24 55.00 219.33 73.33 33+66.66 Existing 223.98 218.58 218.43 217.98 217.87 32 218.43 0.00 218.63 56.00 218.76 111.99 218.86 167.99 218.95 223.98 35+33.53 Existing 166.87 218.04 218.31 217.60 217.79 33 218.31 0.00 218.52 41.72 218.64 83.44 218.74 125.15 218.84 166.87 35+69.82 Existing 36.29 218.31 218.18 217.86 217.73 34 218.18 0.00 218.38 9.07 218.51 18.15 218.61 27.22 218.70 36.29 38+30.41 Existing 260.59 218.37 218.34 217.86 217.86 35 218.34 0.00 218.55 65.15 218.67 130.30 218.77 195.44 218.87 260.59 39+02.30 Existing 71.89 217.61 217.99 217.12 217.49 36 217.99 0.00 218.20 17.97 218.32 35.95 218.42 53.92 218.52 71.89 39+34.10 Existing 31.80 219.62 218.62 213.00 215.06 37 218.62 0.00 218.82 7.95 218.95 15.90 219.05 23.85 219.14 31.80 39+59.83 Existing 25.73 219.32 219.47 218.08 215.54 38 219.47 0.00 219.68 6.43 219.80 12.87 219.90 19.30 220.00 25.73 40+21.45 Existing 61.62 217.85 218.59 217.44 217.76 39 218.59 0.00 218.79 15.41 218.92 30.81 219.02 46.21 219.11 61.62 40+63.14 Existing 41.69 219.31 218.58 218.26 217.85 40 218.58 0.00 218.79 10.42 218.91 20.85 219.01 31.27 219.11 41.69 40+95.53 Existing 32.39 219.50 219.41 218.71 218.49 41 219.41 0.00 219.61 8.10 219.74 16.20 219.84 24.29 219.93 32.39 44+51.93 Existing 356.40 219.50 219.50 219.00 218.86 42 219.50 0.00 219.71 89.10 219.83 178.20 219.93 267.30 220.03 356.40 48+31.01 New 120.60 218.58 219.56 218.58 219.56 43 219.56 0.00 219.79 30.15 219.94 60.30 220.05 90.45 220.16 120.60 48+62.10 New 31.09 218.68 218.63 218.68 218.63 44 218.63 0.00 218.87 7.77 219.01 15.55 219.13 23.32 219.23 31.09 48+92.77 New 30.67 219.29 218.99 219.29 218.99 45 218.99 0.00 219.22 7.67 219.37 15.34 219.48 23.00 219.59 30.67 Head Wall Opening 50+57.76 New 57.05 217.06 218.09 217.06 218.09 46 218.09 0.00 218.32 14.26 218.47 28.53 218.58 42.79 218.69 57.05 Head Wall Opening 51+05.50 New 47.74 220.90 218.98 220.90 218.98 47 218.98 0.00 219.22 11.93 219.36 23.87 219.48 35.80 219.58 47.74 Ped Opening D 51+87.50 Existing 2.00 219.37 218.43 48 219.37 0.00 219.57 0.50 219.70 1.00 219.80 1.50 219.89 2.00 Ped Opening E 53+02.00 Existing 114.50 219.38 219.38 218.86 218.86 49 219.38 0.00 219.59 28.63 219.71 57.25 219.81 85.88 219.91 114.50 Ped Opening E 53+05.50 Existing 3.50 219.38 218.84 50 219.38 0.00 219.59 0.88 219.71 1.75 219.81 2.63 219.91 3.50 Ped Opening F 54+50.00 Existing 144.50 219.38 219.38 218.81 218.81 51 219.38 0.00 219.59 36.13 219.71 72.25 219.81 108.38 219.91 144.50 65+06.19 Existing 22.43 218.23 219.52 218.87 219.15 52 219.52 0.00 219.72 5.61 219.85 11.21 219.95 16.82 220.04 22.43 65+28.75 Existing 22.56 220.80 219.52 219.92 219.40 53 219.52 0.00 219.72 5.64 219.85 11.28 219.95 16.92 220.04 22.56 q = 1.00 cfs/ft Existing Alignment q = 0.00 cfs/ft q = 0.25 cfs/ft q = 0.50 cfs/ft q = 0.75 cfs/ft

NRC RAI (TAC NOS. MF1117 and MF1118)

ATTACHMENT RAI 4 -1 Spreadsheet Files Sheet 2 of 3 Calculate flow rate based on the selected water depth intervals:

1 7

13 19 25 31 37 43 49 55 61 67 73 79 85 91 97 103 109 115 121 HW (ft)

Q(1) (cfs)

Q(2) (cfs) 217.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.6 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.7 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.8 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

217.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

218.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

218.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

218.2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

218.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

218.4 0

0 0.15 0.15 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

218.5 0

0 1.65 1.60 0

0 0

0 0

0 0

0 0

0 0

0 0

1.07 0.94 0

0 218.6 0

0 3.61 3.56 8.88 0

0 0

0 0

0 0

0 0

0 0

0 2.72 3.04 0

0 218.7 0

0 6.02 6.01 22.27 0.59 0.75 0

0 0

0 0

0 0

0 0

0 4.82 5.75 0.31 0

218.8 0

0.60 8.91 8.97 39.08 2.39 2.60 5.91 0

0 0

0 0

0 0

0 0

7.36 9.05 3.28 0

218.9 0

32.98 12.25 12.42 59.32 4.73 5.00 24.06 0

0 0

0 0

0 0

0 0

10.36 12.95 7.17 0

219.0 0

77.46 16.06 16.37 82.99 7.62 7.94 48.07 1.23 0.73 0

0 0

0 0

0 3.73 13.81 17.44 11.98 0

219.1 0

134.06 20.32 20.82 110.08 11.06 11.43 77.92 3.08 2.18 2.05 0

0 0

0 0

20.66 17.71 22.54 17.71 0

219.2 0

202.75 25.06 25.77 140.60 15.05 15.48 113.62 5.44 4.09 9.13 0.57 0

0 0

0 42.71 22.06 28.23 24.36 0

219.3 0

283.56 30.25 31.22 174.55 19.59 20.07 155.17 8.33 6.44 18.50 2.28 1.16 0

0 0

69.88 26.86 34.51 31.93 0

219.4 0

376.47 35.90 37.16 211.92 24.68 25.20 202.58 11.75 9.23 30.16 4.49 2.83 6.65 0

0 102.17 32.11 41.40 40.42 0

219.5 0

481.48 42.02 43.61 252.72 30.32 30.89 255.83 15.69 12.47 44.12 7.21 4.95 21.65 0

0 139.59 37.80 48.88 49.83 0

219.6 0

598.61 48.60 50.55 296.94 36.50 37.12 314.94 20.16 16.16 60.37 10.43 7.50 40.95 0

0 182.12 43.95 56.96 60.15 0

219.7 0

727.83 55.64 57.99 344.59 43.24 43.91 379.90 25.15 20.30 78.92 14.16 10.48 64.54 0

0 229.77 50.55 65.64 71.40 0

219.8 2.48 869.17 63.15 65.93 395.67 50.52 51.24 450.70 30.66 24.88 99.76 18.39 13.90 92.44 0

0 282.54 57.60 74.92 83.56 1.44 219.9 11.16 1022.61 71.11 74.37 450.17 58.36 59.12 527.36 36.71 29.91 122.89 23.13 17.76 124.63 0

0.00 340.43 65.10 84.79 96.64 5.30 220.0 22.82 1188.15 79.54 83.31 508.10 66.74 67.54 609.87 43.27 35.38 148.32 28.37 22.06 161.11 2.34 0.89 403.44 73.05 95.26 110.65 10.15 220.2 55.06 1555.57 97.79 102.68 634.24 85.16 86.04 792.44 57.98 47.67 206.06 40.38 31.96 246.98 12.55 6.68 544.82 90.30 117.99 141.41 22.87 220.4 99.20 1971.40 117.88 124.05 774.09 105.77 106.73 998.41 74.78 61.74 272.97 54.40 43.61 350.04 27.60 15.72 706.67 109.35 143.12 175.85 39.60 220.6 155.24 2435.66 139.82 147.41 927.64 128.58 129.61 1227.78 93.68 77.60 349.05 70.44 57.00 470.28 47.50 28.01 889.01 130.20 170.63 213.96 60.33 CHECK MIN 219.76 218.80 218.39 218.39 218.51 218.66 218.65 218.76 218.91 218.93 219.06 219.16 219.21 219.34 219.93 219.95 218.97 218.41 218.44 218.69 219.75 A

148.77 605.30 23.11 24.93 171.32 27.46 27.40 292.53 26.24 22.32 114.69 25.25 21.83 214.86 60.59 40.63 255.99 22.51 29.87 45.95 50.08 B

(65327)

(264618)

(10083)

(10879)

(74782)

(11996)

(11971)

(127860)

(11478)

(9765)

(50197)

(11053)

(9562)

(94154)

(26620)

(17854)

(111978)

(9821)

(13036)

(20076)

(21980)

C 7171481 28920369 1099724 1186650 8160967 1310053 1307254 13971218 1255105 1067934 5492625 1209843 1046890 10314595 2923875 1961689 12245837 1071386 1422172 2192512 2411945

NRC RAI (TAC NOS. MF1117 and MF1118)

ATTACHMENT RAI 4 -1 Spreadsheet Files Sheet 3 of 3 (continue) Calculate flow rate based on the selected water depth intervals:

127 133 139 145 151 157 163 169 175 181 187 193 199 205 211 217 223 229 235 241 247 253 259 265 271 277 283 289 295 301 307 313 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.08 1.01 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

-0.05 0

0 0.60 3.8 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 10.8 2.10 0

0 1.30 7.7 0

0 0

0 0

0 0

0.45 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 36.4 4.95 0

0 2.15 12.4 0

0 0

0 0

0 0

8.0 0

0 0

0 0

0 0

0 0

0.51 0

0 0

0 0

0 0

0 70.4 8.50 0

0 3.2 18.2 0

0 0

0 0

0.70 0

18.7 0

0 0

0 0

0 0

0 0

5.7 0

0 0

0 0

0 0

0 113 12.75 0

0 4.3 25.0 0

0 0

0 0

4.8 0

32.3 0

0 0

0 0

0 0

0 0

12.7 0

0 0

0 0

0 0

0 164 17.71 0

0 5.7 32.7 0

0 0

0 14.6 10.4 14.0 49.0 0

0 0

0 0

0 0

0 0

21.5 0

0 0

0 0

0 0

4.30 224 23.37 0

0 7.2 41.4 0

0 0

15.7 37.8 17.5 47.0 68.8 0

0 0

0 0

0 0

0 0

32.2 0

0 0

0 0

0 0

15.3 292 29.73 0

0 8.8 51.1 0

0 0

45.5 68.1 26.1 91.0 91.5 0

0 0.65 0.62 0

0 0

0 0

44.7 0

0 0

0 0

0 0

30.1 368 36.79 0

0 10.6 61.8 5.17 0

0 84.7 105 36.3 146 117 2.6 0

7.3 5.2 0

0 0

1.7 0

59.0 0

0 0

0 0

0 0

48.6 453 44.56 0

0 12.6 73.4 13.42 0

0 133 150 48.1 212 146 7.0 0

16.5 11.5 0

0 0

5.1 0

75.1 0

0 0

0 0

0 0

70.8 547 53.03 24.0 1.90 14.8 86.0 24.18 0

6.8 192 201 61.3 289 178 12.7 0

28.4 19.6 0

0 0

9.4 0

93.1 0

0 0

0 0

0 0

96.8 649 62.21 71.1 9.4 17.1 99.6 37.43 0

17.2 259 260 76.1 377 213 19.7 0

42.8 29.5 0

0 0

14.8 0.27 113 0.60 0

0 0

0 0

0 126.5 760 72.08 132 19.4 19.5 114 53.19 0

30.7 336 325 92.4 476 251 28.1 0

59.9 41.1 0

0 0

21.2 3

135 5.0 0

0 0

0 0

0 160.0 879 82.66 206 31.8 22.1 130 71.45 0

47.3 423 398 110 586 292 37.8 0

79.5 54.5 0

0 0

28.5 7

158 10.9 0

0 0

0 0

0 197.2 1006 93.94 294 46.7 24.9 146 92.21 0

66.9 519 478 130 707 336 48.9 0

102 69.6 0

0 0

36.9 12 183 18.4 0

0 0

0 0

0 238 1143 106 396 64.0 27.9 164 115 0

89.7 624 564 151 839 383 61.4 0

127 86.5 0

0 0

46.2 17 210 27.4 0.06 1.7 0.05 2.16 0

0 283 1287 119 511 83.8 31.0 182 141 5.13 116 739 658 173 983 433 75.1 0.62 154 105 3.02

-0.70 0.00 56.5 24 239 37.9 0.29 14.3 0.44 18.0 0

0 331 1440 132 640 106 34.2 202 170 12.9 145 864 759 197 1137 486 90.2 3.6 184 126 7.6 35.4 3.9 67.9 32 270 50.0 0.6 31.7 0.97 40.0 1.83 1.84 383 1602 146 783 131 37.7 222 200 23.0 177 998 867 223 1302 542 107 7.6 217 148 13.6 86.6 16.0 80.2 40 303 63.6 1.0 53.9 1.65 68.1 4.91 4.93 439 1772 161 939 158 41.3 244 234 35.4 212 1141 982 250 1478 602 124 12.7 252 172 20.9 153 32.0 93.5 50 337 78.7 1.5 81.0 2.48 102 8.93 8.98 499 1951 176 1109 187 45 266 269 50 250 1294 1104 278 1665 664 144 18.9 290 197 30 234 52 108 61 373 95 2

113 3

143 14 14 562 2138 193 1293 220 49 289 308 67 291 1456 1233 308 1863 729 164 26.2 330 225 40 330 76 123 72 411 114 3

150 5

189 20 20 700 2538 227 1701 291 57 339 392 108 383 1809 1512 373 2292 869 209 44.0 419 285 64 568 134 157 99 493 154 4

238 7

300 35 35 853 2972 264 2164 372 66 393 486 159 488 2200 1819 444 2766 1021 259 66.1 518 352 94 866 209 194 129 582 202 6

345 11 435 53 53 1021 3440 305 2681 464 76 450 590 218 604 2628 2155 521 3283 1185 315 92.7 628 427 129 1225 299 236 163 678 255 8

472 14 595 75 76 218.45 217.94 217.90 218.83 218.87 217.78 217.75 218.61 219.41 218.81 218.43 218.31 218.18 218.34 217.99 218.62 219.47 218.59 218.58 219.41 219.50 219.56 218.63 218.99 218.09 218.98 219.37 219.38 219.38 219.38 219.52 219.52 186.97 425.54 35.14 682.74 122.82 8.05 48.92 125.08 116.11 154.88 473.08 352.46 76.65 550.41 151.84 67.17 54.35 130.15 88.06 68.41 752.77 193.23 49.81 49.14 91.41 76.49 4.22 241.84 7.39 305.21 47.38 47.65 (81614)

(185321)

(15296)

(298499)

(53710)

(3503)

(21285)

(54641)

(50904)

(67720)

(206486)

(153755)

(33417)

(240143)

(66143)

(29342)

(23834)

(56849)

(38461)

(29994)

(330181)

(84765)

(21760)

(21501)

(39829)

(33467)

(1852)

(106019)

(3241)

(133797)

(20781)

(20902) 8906276 20176835 1664532 32626677 5871645 380976 2315384 5967320 5579463 7402317 22531191 16768552 3642223 26193559 7202953 3204482 2613148 6207735 4199750 3287589 36206010 9296019 2376291 2351816 4338748 3660599 202926 11619121 355169 14663425 2278946 2292154