ML14071A315

From kanterella
Jump to navigation Jump to search

NRR E-mail Capture - Second RAI for Millsone 2 - RR-04-16, UT in Lieu of RT
ML14071A315
Person / Time
Site: Millstone 
Issue date: 03/12/2014
From: James Kim
Division of Operating Reactor Licensing
To: Bartron W, Craft W
Dominion Energy Co
References
MF2520
Download: ML14071A315 (2)


Text

1 NRR-PMDAPEm Resource From:

Kim, James Sent:

Wednesday, March 12, 2014 9:23 AM To:

Wanda D Craft (wanda.d.craft@dom.com); William D Bartron (william.d.bartron@dom.com)

Cc:

Thadani, Mohan; Cumblidge, Stephen

Subject:

Second RAI for Millsone 2 - RR-04-16, UT in lieu of RT (TAC No. MF2520)

Bill & Wanda, The U.S. Nuclear Regulatory Commission staff requests that the licensee provide additional information to support the relief from ASME Code Section XI-required radiographic testing of welds.

This email is considered as a formal RAI request and a copy of this email will be made publicly available.

SECOND REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELIEF REQUEST RR-04-16 REGARDING PHASED ARRAY ULTRASONIC EXAMINATION TECHNIQUES IN LIEU OF RADIOGRAPHY DOMINION NUCLEAR CONNECTICUT INC MILLSTONE POWER STATION UNIT 2 DOCKET NO. 50-336 (TAC NO.MF2520)

By letter dated August 1 2013, (Agencywide Documents Access & Management System (ADAMS) Accession No.ML13220A019) and amended by letters dated November 22, 2013 and February 27, 2014, (ADAMS Accession Nos. ML13338A284 and ML14063A206 respectively) Dominion Nuclear Connecticut, Inc. (the licensee) submitted RR-04-16, requesting relief from the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (Code)Section XI, Paragraph IWA-4221. The 2004 Edition of ASME Section XI, paragraph IWA-4221 requires the use of the construction code for repair and replacement activities at Millstone Power Station Unit 2. The licensee is proposing to use phased array ultrasonic testing as an alternative to the required radiographic testing.

The U.S. Nuclear Regulatory Commission (NRC) staff requests that the licensee provide additional information to support the relief from ASME Code Section XI-required radiographic testing of welds.

1. Describe the radiographic testing procedure used to characterize the specimens described in the letter dated February 27 in detail. Identify if the radiographic testing procedure used single or double wall viewing and how many shots and angles were taken per weld.
2. Did the radiographic testing procedure used to evaluate the specimens described in the letter dated February 27 meet the requirements of ASME Code Section V Article 2?
3. Provide a table describing the implanted flaws used to qualify the ultrasonic inspection procedure.

Include the flaw types and dimensions. The NRC staff understands that releasing this information may compromise the blind qualification testing. If this information is proprietary include the necessary affidavit for the NRC staff to treat the information as proprietary.

4. Provide examples of successful ultrasonic detection of planar flaws in the 0.28 inch thick test blocks.

Hearing Identifier:

NRR_PMDA Email Number:

1162 Mail Envelope Properties (James.Kim@nrc.gov20140312092300)

Subject:

Second RAI for Millsone 2 - RR-04-16, UT in lieu of RT (TAC No. MF2520)

Sent Date:

3/12/2014 9:23:07 AM Received Date:

3/12/2014 9:23:00 AM From:

Kim, James Created By:

James.Kim@nrc.gov Recipients:

"Thadani, Mohan" <Mohan.Thadani@nrc.gov>

Tracking Status: None "Cumblidge, Stephen" <Stephen.Cumblidge@nrc.gov>

Tracking Status: None "Wanda D Craft (wanda.d.craft@dom.com)" <wanda.d.craft@dom.com>

Tracking Status: None "William D Bartron (william.d.bartron@dom.com)" <william.d.bartron@dom.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 2601 3/12/2014 9:23:00 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: