JPM RO A1a 1

OPERATOR: ________________________________

RO DATE:

JPM NUMBER:

RO A1a TASK NUMBER:

Conduct of Operations TASK TITLE:

2-SR-2, Mode 3 Operator Rounds, Table 1.13 through 1.22 K/A NUMBER: 2.1.7 K/A RATING: RO 4.4 TASK STANDARD: Perform Operator logs in accordance with SR-2 Instrument Checks and Observations for log tables 1.13 through 1.22. Verify acceptance criteria are satisfied in accordance with notes and if not notification to Unit Supervisor is completed.

LOCATION OF PERFORMANCE: Simulator REFERENCES/PROCEDURES NEEDED: 2-SR-2, Instrument Checks and Observations VALIDATION TIME: 30 minutes PERFORMANCE TIME:

COMMENTS: __________________________________________________________

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

SIGNATURE: __________________________

DATE: __________

EXAMINER

INITIAL CONDITIONS: You are a Unit Operator assigned to Unit 2, and it is Friday morning at 0800. 2-SR-2, Instrument Checks and Observations, is being performed.

The plant is in MODE 3.

INITIATING CUE: The Unit Supervisor directs you as the Unit Operator to complete a portion of 2-SR-2 day shift checks and observations Attachment 2 Surveillance Procedure Data Package Modes 1, 2, and 3 (pages 18 of 90 to 27 of 90) for Friday at 0800.

All readings that are already completed are correct and need not be checked by you.

JPM RO A1a 3

Simulator INITIAL CONDITIONS: You are a Unit Operator assigned to Unit 2, and it is Friday morning at 0800. 2-SR-2, Instrument Checks and Observations, is being performed.

The plant is in MODE 3.

INITIATING CUE: The Unit Supervisor directs you as the Unit Operator to complete a portion of 2-SR-2 day shift checks and observations Attachment 2 Surveillance Procedure Data Package Modes 1, 2, and 3 (pages 18 of 90 to 27 of 90) for Friday at 0800.

All readings that are already completed are correct and need not be checked by you.

JPM RO A1a 4

START TIME Performance Step 1:

Critical X Not Critical (1)

Whenever there is fuel in the reactor vessel and the continuous conductivity monitor is inoperable, periodic analysis of reactor coolant samples are required by the Technical Requirements Manual. If the reactor coolant continuous conductivity monitor becomes inoperable, notify the Chemistry to sample according to 2-SI-4.6.B.1-4.

Standard:

Records a Reactor Coolant Conductivity reading of.057 or.058 µmho. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 5

Performance Step 2:

Critical X Not Critical (1)

The difference between readings of 2-LI-64-54A and 2-LI-64-66 should not exceed 2 inches. Deviations greater than 2 inches should be investigated.

(2)

The Technical Specification requirements for Suppression Pool Water Level are -6.25" and -1.0" with DW to Torus DP established AND -7.25" and -1.0" without DW to Torus DP established.

Standard:

Records a Suppression Pool Level of (-) 1 to (-) 2 inches in both columns. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 6

Performance Step 3:

Critical X Not Critical (1)

The required observation of Bulk Volumetric Average Drywell Air Temperature may be obtained from ICS Pt TEST2500 or 2-TR-80 or 2-TI-82 Value. Only one of the three methods is required to be logged and the other method may be N/Ad.

(2)

It may be necessary to have Instrument Maintenance turn on the BULK VOLUMETRIC AVERAGE DRYWELL AIR TEMPERATURE on 2-TR-80-1 to allow the point to be displayed.

Standard:

Records a Drywell Air Temperature from ICS of 102.4 °F or 102.5 °F in the column under ICS Pt TEST2500. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 7

Performance Step 4:

Critical Not Critical X (1)

Acceptance Criteria is not required to be met until 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is > 15% RTP following startup, TO 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to < 15% RTP prior to the next scheduled reactor shutdown.)

(2)

The Drywell-Suppression Chamber Differential Pressure should not exceed 1.33 psid.

Standard:

Records a Drywell - Suppression Chamber Differential pressure of 1.15 to 1.2 psid in both columns. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 8

Performance Step 5:

Critical X Not Critical NOTES ARE ON THE FOLLOWING PAGE!

JPM RO A1a 9

(1) Limits:

95°F when any OPERABLE intermediate range monitor (IRM) channel is > 70 on Range 7 and no testing that adds heat to the suppression pool is being performed; 105°F when any OPERABLE IRM channel is > 70 on Range 7 and testing that adds heat to the suppression pool is being performed; and 110°F when all OPERABLE IRM channels are 70 on Range 7 (2)

This value is recorded to further validate the Suppression Pool Bulk Water Temperature indications when RHR Suppression Pool Cooling is not in service. If the Control Room Suppression Pool Bulk Water Temperature indications deviate more than 5°F from one another or the 2-TI-64-55B is greater than or equal to 95 deg F, RHR Suppression Pool Cooling may be required to be placed in service to obtain a valid Suppression Pool Bulk Water Temperature readings (may indicate a potential thermal stratification problem, REFER TO site response to GE SIL 106). Deviations in excess of 5°F for the MCR instruments is also an indication of a potential inoperable instrument; the Suppression Pool Bulk Water Temperature instruments affect LCO 3.3.3.1, "PAM Instruments" (CHANNEL CHECK surveillance requirement) and 2-TI-64-55B affects LCO 3.3.3.2, "Backup Control System. Failure of an Analog (Pen), channel to track due to sticking or servo failure, contributing to the channel exceeding the Max Delta Limits or not, results in the channel being Inoperable.

(3)

Suppression pool average temperature must be verified within the applicable limits and logged every 5 minutes when performing testing that adds heat to the suppression pool, accomplished by 2-SR-3.6.2.1.1.

(4)

If both the primary and secondary indication of any SRV tailpipe is inoperable, per Technical Requirements Manual 3.3.5, the Suppression Pool Water Temperature must be monitored at least once per shift to observe any unexplained temperature rise which might be indicative of an open SRV.

Standard:

Records Suppression Pool Water Temperature of 87.5 °F; plus or minus 2 °F in all 4 columns under Panel 9-3. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 10 Performance Step 6:

  • Critical X Not Critical (1)

Each pressure indicator provides indication of the discharge pressure for one RHR or Core Spray Loop. The instrument check will consist of observing that the instrument exhibits an expected reading for the given plant conditions.

(2)

The Technical Requirements Manual requires a minimum discharge pressure for OPERABLE subsystems. Refer to TRM Section 3.5.4.

CS Loop I PI-75-20 39 psig CS Loop II PI-75-48 39 psig RHR Loop I PI-74-51 48 psig RHR Loop II PI-74-65 35 psig (3)

MAX criteria are N/A for RHR/Core Spray subsystems in service or if keep fill aligned to CS & S. When a RHR/Core Spray subsystem is in a standby readiness condition the maximum discharge pressure is 100 psig. High discharge pressures with pumps secured may be indication of primary valve leakage.

Standard:

  • Records a CS Loop I Fill Pressure of 50 psig (+) 5 psig and for *CS Loop II Discharge Fill Pressure of 45 psig (+) 5 psig. *Records a RHR Loop I Discharge Fill Pressure of 42.5 psig; plus 5 psig or minus 2.5 psig but less than 48 psig. Records NA or 270 psig for RHR Loop II because it is in Shutdown Cooling. Initials under UO. *Informs Unit Supervisor that RHR Loop I discharge pressure is less than the minimum required discharge pressure of 48 psig.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 11 Performance Step 7:

Critical Not Critical X (1)

Technical Specification LCO 3.4.7 requires that two RHR Shutdown Cooling Subsystems be operable during this applicability. An operable Shutdown Cooling Subsystem consists of one RHR pump, associated heat exchanger, RHRSW pump capable of providing cooling water to its associated heat exchanger, associated piping and valves, all of which can be aligned in the Shutdown Cooling Mode for the removal of decay heat.

(2)

An X shall be placed in the associated Column for the In Service Pump or Subsystem.

(3)

To be considered as In Service, RHR System and its associated Shutdown Cooling Subsystems must be in the Shutdown Cooling Mode alignment with RHR SD CLG FLOW LOW annunciator (2-XA-55-3D, Window 11) is reset.

Standard:

Places an X under RR Pump B for being in service and an X under RHR Shutdown Cooling Subsystem D for being in service. Records SAT in all data Column. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 12 Performance Step 8:

Critical Not Critical X Standard:

Records Reactor Zone Exhaust Radiation Monitor readings of 1.0 mr/hr for both RM-90-142 and RM-90-143; plus or minus 0.5 mr/hr for Detector A and B. Records Refuel Zone Exhaust Radiation Monitor readings of 26.0 mr/hr for RM-90-140; plus or minus 1.0 mr/hr for Detector A and B. For RM-90-141 records reading of 50 mr/hr; plus or minus 1 mr/hr for Detector A and B.

Initials under UO. Informs Unit Supervisor that Refuel Zone Exhaust Radiation Monitors are outside the MAX deviation of 20 mr/hr.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 13 Performance Step 9:

  • Critical X Not Critical (1)

The instrument check will consist of observing that the instruments exhibit an expected reading for the given plant conditions. MAX will be the alarm (RHRSW/RCW EFFLUENT RADIATION HIGH 2-RA-90-132 (Panel 2-9-3, 2-XA-55-3A, Window 3)) setpoint for the respective monitor. Instrument Shop should be contacted for most current setpoints as required.

Standard:

Records NA for RM-90-133 or a reading of 300 cpm. *Records a reading for RM-90-134 of 300 cpm; plus or minus 10 cpm. *Records SAT in all data Column. *Initials under UO.

SAT UNSAT N/A COMMENTS:

END OF TASK STOP TIME

JPM RO A1a 1

OPERATOR: ________________________________

RO DATE:

JPM NUMBER:

RO A1a TASK NUMBER:

Conduct of Operations TASK TITLE:

3-SR-2, Mode 3 Operator Rounds, Table 1.12 through 1.22 K/A NUMBER: 2.1.7 K/A RATING: RO 4.4 TASK STANDARD: Perform Operator logs in accordance with SR-2 Instrument Checks and Observations for log tables 1.13 through 1.22. Verify acceptance criteria are satisfied in accordance with notes and if not notification to Unit Supervisor is completed.

LOCATION OF PERFORMANCE: Simulator REFERENCES/PROCEDURES NEEDED: 3-SR-2, Instrument Checks and Observations VALIDATION TIME: 30 minutes PERFORMANCE TIME:

COMMENTS: __________________________________________________________

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

SIGNATURE: __________________________

DATE: __________

EXAMINER

INITIAL CONDITIONS: You are a Unit Operator assigned to Unit 3, and it is Friday morning at 0800. 3-SR-2, Instrument Checks and Observations, is being performed.

The plant is in MODE 3.

INITIATING CUE: The Unit Supervisor directs you as the Unit Operator to complete a portion of 3-SR-2 day shift checks and observations Attachment 2 Surveillance Procedure Data Package Modes 1, 2, and 3 (pages 17 of 88 to 26 of 88) for Friday at 0800.

All readings that are already completed are correct and need not be checked by you.

JPM RO A1a 3

Simulator INITIAL CONDITIONS: You are a Unit Operator assigned to Unit 3, and it is Friday morning at 0800. 3-SR-2, Instrument Checks and Observations, is being performed.

The plant is in MODE 3.

INITIATING CUE: The Unit Supervisor directs you as the Unit Operator to complete a portion of 3-SR-2 day shift checks and observations Attachment 2 Surveillance Procedure Data Package Modes 1, 2, and 3 (pages 17 of 88 to 26 of 88) for Friday at 0800.

All readings that are already completed are correct and need not be checked by you.

JPM RO A1a 4

START TIME Performance Step 1:

Critical X Not Critical (1)

Whenever there is fuel in the reactor vessel and the continuous conductivity monitor is inoperable, periodic analysis of reactor coolant samples are required by the Technical Requirements Manual. If the reactor coolant continuous conductivity monitor becomes inoperable, notify Chemistry to sample according to 3-SI-4.6.B.1-4.

Standard:

Records a Reactor Coolant Conductivity reading of.057 or.058 µmho. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 5

Performance Step 2:

Critical X Not Critical (1)

The difference between readings of 3-LI-64-54A and 3-LI-64-66 should not exceed 2 inches. Deviations greater than 2 inches should be investigated.

(2)

The Technical Specification requirements for Suppression Pool Water Level are -6.25" and -1.0" with DW to Torus DP established AND -7.25" and -1.0" without DW to Torus DP established.

Standard:

Records a Suppression Pool Level of (-) 2.75 inches; plus or minus 0.5 inches in both columns. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 6

Performance Step 3:

Critical X Not Critical (1)

The required observation of Bulk Volumetric Average Drywell Air Temperature may be obtained from ICS Pt TEST2500 OR 3-TI-82 OR 3-TR-80-1. Only one of the two methods is required to be logged and the other method may be N/Ad.

(2)

It may be necessary to have Instrument Maintenance turn on the BULK VOLUMETRIC AVERAGE DRYWELL AIR TEMPERATURE on 3-TR-80-1 to allow the point to be displayed.

Standard:

Records a Drywell Air Temperature from ICS of 104.1 °F; plus or minus 0.1 °F in the column under ICS Pt TEST2500. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 7

Performance Step 4:

Critical Not Critical X (1) The Drywell-Suppression Chamber Differential Pressure should not exceed 1.33 psid.

Standard:

Records a Drywell - Suppression Chamber Differential pressure of 1.1 to 1.2 psid in both columns. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 8

Performance Step 5:

Critical X Not Critical (1) Limits:

A. 95°F when any OPERABLE intermediate range monitor (IRM) channel is > 70 on Range 7 and no testing that adds heat to the suppression pool is being performed.

B. 105°F when any OPERABLE IRM channel is > 70 on Range 7 and testing that adds heat to the suppression pool is being performed; and C. 110°F when all OPERABLE IRM channels are 70 on Range 7 (2)

This value is recorded to further validate the Suppression Pool Bulk Water Temperature indications when RHR Suppression Pool Cooling is not in service. If the Control Room Suppression Pool Bulk Water Temperature indications deviate more than 5°F from one another or if 3-TI-64-55B is greater than or equal to 95 deg F, RHR Suppression Pool Cooling may be required to be placed in service to obtain valid Suppression Pool Bulk Water Temperature readings (may indicate a potential thermal stratification problem, Refer To site response to GE SIL 106). Deviations in excess of 5°F for the MCR instruments is also an indication of a potential inoperable instrument; the Suppression Pool Bulk Water Temperature instruments affect LCO 3.3.3.1, "PAM Instruments" (CHANNEL CHECK surveillance requirement) and 3-TI-64-55B affects LCO 3.3.3.2, "Backup Control System.

(3)

Suppression pool average temperature must be verified within the applicable limits and logged every 5 minutes when performing testing that adds heat to the suppression pool, accomplished by 3-SR-3.6.2.1.1.

(4)

If both the primary and secondary indication of any SRV tailpipe is inoperable, per Technical Requirements Manual 3.3.5, the Suppression Pool Water Temperature must be monitored at least once per shift to observe any unexplained temperature rise which might be indicative of an open SRV.

Standard:

Records Suppression Pool Water Temperature of 87.5 °F; plus or minus 2.5 °F in all 4 columns under Panel 9-3. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 9

Performance Step 6:

Critical X Not Critical (1) Each pressure indicator provides indication of the discharge pressure for one RHR or Core Spray Loop. The instrument check will consist of observing that the instrument exhibits an expected reading for the given plant conditions.

(2) The Technical Requirements Manual requires a minimum discharge pressure for OPERABLE subsystems. Refer To TRM Section 3.5.4.

CS Loop I PI-75-20 39 psig CS Loop II PI-75-48 39 psig RHR Loop I PI-74-51 48 psig RHR Loop II PI-74-65 35 psig (3) MAX criteria is N/A for RHR/Core Spray subsystems in service or if keep fill aligned to CS & S. When a RHR/Core Spray subsystem is in a standby readiness condition the maximum discharge pressure is 100 psig. High discharge pressures with pumps secured may be indication of primary valve leakage.

Standard:

  • Records a CS Loop I Fill Pressure of 50 psig (+) 5 psig and for *CS Loop II Discharge Fill Pressure of 50 psig (+) 5 psig. *Records a RHR Loop I Discharge Fill Pressure of 40 psig; (+) 5 psig. Records NA or 270 psig for RHR Loop II because it is in Shutdown Cooling. Initials under UO. *Informs Unit Supervisor that RHR Loop I discharge pressure is less than the minimum required discharge pressure of 48 psig.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 10 Performance Step 7:

Critical Not Critical X (1)

Technical Specification LCO 3.4.7 requires that two RHR Shutdown Cooling Subsystems be operable during this applicability. An operable Shutdown Cooling Subsystem consists of one RHR pump, associated heat exchanger, RHRSW pump capable of providing cooling water to its associated heat exchanger, associated piping and valves, all of which can be aligned in the Shutdown Cooling Mode for the removal of decay heat.

(2)

An X shall be placed in the associated Column for the In Service Pump or Subsystem.

(3)

To be considered as In Service, RHR System and its associated Shutdown Cooling Subsystems must be in the Shutdown Cooling Mode alignment with RHR SD CLG FLOW LOW annunciator (3-XA-55-3D, Window 11) RESET.

Standard:

Places an X under RR Pump B for being in service and an X under RHR Shutdown Cooling Subsystem D for being in service. Records SAT in all data Column. Initials under UO.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 11 Performance Step 8:

Critical Not Critical X Standard:

Records Reactor Zone Exhaust Radiation Monitor readings of 1.0 mr/hr for both RM-90-142 and RM-90-143; plus or minus 0.5 mr/hr for Detector A and B. Records Refuel Zone Exhaust Radiation Monitor readings of 26.0 mr/hr for RM-90-140; plus or minus 1.0 mr/hr for Detector A and B. For RM-90-141 records reading of 50 mr/hr; plus or minus 1 mr/hr for Detector A and B.

Initials under UO. Informs Unit Supervisor that Refuel Zone Exhaust Radiation Monitors are outside the MAX deviation of 20 mr/hr.

SAT UNSAT N/A COMMENTS:

JPM RO A1a 12 Performance Step 9:

  • Critical X Not Critical (1) The instrument check will consist of observing that the instruments exhibit an expected reading for the given plant conditions. MAX will be the alarm (RHRSW/RCW EFFLUENT RADIATION HIGH 3-RA-90-132 (Panel 3-9-3, 3-XA-55-3A, Window 3)) setpoint for the respective monitor. Instrument Shop should be contacted for most current setpoints as required.

Standard:

Records NA for RM-90-133 or a reading of 300 cpm. *Records a reading for RM-90-134 of 300 cpm; plus or minus 10 cpm. *Records SAT in all data Column. *Initials under UO.

SAT UNSAT N/A COMMENTS:

END OF TASK STOP TIME

JPM RO A1b 1

OPERATOR: ________________________________

RO DATE:

JPM NUMBER:

RO A1b TASK NUMBER:

U-078-AB-01 TASK TITLE: Calculate Time to Reach Temperature Targets for Loss of Fuel Pool Cooling K/A NUMBER: 2.1.25 K/A RATING: RO 3.9 TASK STANDARD: Complete of SRM Operability surveillance and determine if core alterations may commence.

LOCATION OF PERFORMANCE: Simulator REFERENCES/PROCEDURES NEEDED: 2-AOI-78-1, Fuel Pool Cleanup System Failure VALIDATION TIME: 10 minutes PERFORMANCE TIME:

COMMENTS: __________________________________________________________

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

SIGNATURE: __________________________

DATE: __________

EXAMINER

INITIAL CONDITIONS: You are a Reactor Operator on Unit 2. The RBCCW sectionalizing valve has failed closed. The Unit Supervisor has entered 2-AOI-70-1, Loss of Reactor Building Closed Cooling Water and 2-AOI-78-1, Fuel Pool Cleanup System Failure.

INITIATING CUES: The Unit Supervisor directs you to estimate the time for the fuel pool temperature to rise to 125 °F, 150 °F, and 200 °F in accordance with 2-AOI-78-1 step 3.7.

JPM RO A1b 3

Simulator INITIAL CONDITIONS: You are a Reactor Operator on Unit 2. The RBCCW sectionalizing valve has failed closed. The Unit Supervisor has entered 2-AOI-70-1, Loss of Reactor Building Closed Cooling Water and 2-AOI-78-1, Fuel Pool Cleanup System Failure.

INITIATING CUES: The Unit Supervisor directs you to estimate the time for the fuel pool temperature to rise to 125 °F, 150 °F, and 200 °F in accordance with 2-AOI-78-1 step 3.7.

JPM RO A1b 4

START TIME Performance Step 1:

Critical Not Critical X 2-AOI-78-1 Fuel Pool Cleanup System Failure

[3.7] ESTIMATE the time for the fuel pool temperature to rise to 125°F, 150°F, and 200°F using the heat up rates as provided on Attachment 1, Table 1 at least once per shift UNTIL Fuel Pool cooling is restored:

Standard:

Proceeds to attachment 1 of 2-AOI-78-1 SAT UNSAT N/A COMMENTS:

Performance Step 2:

Critical X Not Critical (Page 2 of 2)

Spent Fuel Pool Heat-up Rate at Normal Fuel Pool Level NOTE Determine time to reach target temperatures of 125°F, 150°F and 200°F using the most conservative Heat-up Rate (the highest rate) for days that fall between the dates listed on Table 1.

Target Temperature 125 °F Actual fuel pool temp(°F)

- °F Standard:

Records Actual Fuel Pool Temperature of 96.3 °F, can record 96 °F to 97 °F under each of the Target Temperatures (3 places).

SAT UNSAT N/A COMMENTS:

JPM RO A1b 5

Performance Step 3:

Critical X Not Critical Difference Standard:

Calculates the difference 125 - actual temperature recorded; can record any of the following temperatures 28 °F to 29 °F.

SAT UNSAT N/A COMMENTS:

Performance Step 4:

Critical X Not Critical Heat up rate from Table 1

÷ °F/hr Standard:

Records the Heat up rate from Table 1 of 1.37 °F under each of the Target Temperatures (3 places)

SAT UNSAT N/A COMMENTS:

Performance Step 5:

Critical X Not Critical TIME (in hours) For FUEL POOL TO REACH Target Temperature

= hrs Standard:

Divides the difference by 0.99 and calculates a time to reach 125 °F of one of the following 20.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to 21.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

SAT UNSAT N/A COMMENTS:

JPM RO A1b 6

Performance Step 6:

Critical X Not Critical Difference Standard:

Calculates the difference 150 - actual temperature recorded; can record any of the following temperatures 53 °F to 54 °F.

SAT UNSAT N/A COMMENTS:

Performance Step 7:

Critical X Not Critical TIME (in hours) For FUEL POOL TO REACH Target Temperature

= hrs Standard:

Divides the difference by 1.37 and calculates a time to reach 150 °F of one of the following 38.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> to 39.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

SAT UNSAT N/A COMMENTS:

Performance Step 8:

Critical X Not Critical Difference Standard:

Calculates the difference 200 - actual temperature recorded; can record any of the following temperatures 103 °F to 104 °F.

SAT UNSAT N/A COMMENTS:

JPM RO A1b 7

Performance Step 9:

Critical X Not Critical TIME (in hours) For FUEL POOL TO REACH Target Temperature

= hrs Standard:

Divides the difference by 1.37 and calculates a time to reach 200 °F of one of the following 75.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to 75.9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />.

SAT UNSAT N/A COMMENTS:

END OF TASK STOP TIME

JPM RO A1b 1

OPERATOR: ________________________________

RO DATE:

JPM NUMBER:

RO A1b TASK NUMBER:

U-078-AB-01 TASK TITLE: Calculate Time to Reach Temperature Targets for Loss of Fuel Pool Cooling K/A NUMBER: 2.1.25 K/A RATING: RO 3.9 TASK STANDARD: Complete of SRM Operability surveillance and determine if core alterations may commence.

LOCATION OF PERFORMANCE: Simulator REFERENCES/PROCEDURES NEEDED: 3-AOI-78-1, Fuel Pool Cleanup System Failure VALIDATION TIME: 10 minutes PERFORMANCE TIME:

COMMENTS: __________________________________________________________

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

SIGNATURE: __________________________

DATE: __________

EXAMINER

INITIAL CONDITIONS: You are a Reactor Operator on Unit 3. The RBCCW sectionalizing valve has failed closed. The Unit Supervisor has entered 3-AOI-70-1, Loss of Reactor Building Closed Cooling Water and 3-AOI-78-1, Fuel Pool Cleanup System Failure.

INITIATING CUES: The Unit Supervisor directs you to estimate the time for the fuel pool temperature to rise to 125 °F, 150 °F, and 200 °F in accordance with 3-AOI-78-1 step 3.7.

JPM RO A1b 3

Simulator INITIAL CONDITIONS: You are a Reactor Operator on Unit 3. The RBCCW sectionalizing valve has failed closed. The Unit Supervisor has entered 3-AOI-70-1, Loss of Reactor Building Closed Cooling Water and 3-AOI-78-1, Fuel Pool Cleanup System Failure.

INITIATING CUES: The Unit Supervisor directs you to estimate the time for the fuel pool temperature to rise to 125 °F, 150 °F, and 200 °F in accordance with 3-AOI-78-1 step 3.7.

JPM RO A1b 4

START TIME Performance Step 1:

Critical Not Critical X 3-AOI-78-1 Fuel Pool Cleanup System Failure

[3.7] ESTIMATE the time for the fuel pool temperature to rise to 125°F, 150°F, and 200°F using the heat up rates as provided on Attachment 1, Table 1 at least once per shift UNTIL Fuel Pool cooling is restored:

Standard:

Proceeds to attachment 1 of 3-AOI-78-1 SAT UNSAT N/A COMMENTS:

Performance Step 2:

Critical X Not Critical (Page 2 of 2)

Spent Fuel Pool Heat-up Rate at Normal Fuel Pool Level NOTES

1)

To determine time to reach target temperatures of 125°F, 150°F, and 200°F USE the following formulas.

2)

Use the most conservative heat up rate (the highest rate) for days that fall between the dates listed on Table 1.

Target Temperature 125 °F Actual fuel pool temp(°F)

- °F Standard:

Records Actual Fuel Pool Temperature of 97.7 °F, can record 97 °F to 98 °F under each of the Target Temperatures (3 places).

SAT UNSAT N/A COMMENTS:

JPM RO A1b 5

JPM RO A1b 6

Performance Step 3:

Critical X Not Critical Difference Standard:

Calculates the difference 125 - actual temperature recorded; can record any of the following temperatures 28 °F to 29 °F.

SAT UNSAT N/A COMMENTS:

Performance Step 4:

Critical X Not Critical Heat up rate from Table 1

÷ °F/hr Standard:

Records the Heat up rate from Table 1 of 0.99 °F under each of the Target Temperatures (3 places).

SAT UNSAT N/A COMMENTS:

Performance Step 5:

Critical X Not Critical TIME (in hours) For FUEL POOL TO REACH Target Temperature

= hrs Standard:

Divides the difference by 0.99 and calculates a time to reach 125 °F of one of the following 27.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to 28.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />.

SAT UNSAT N/A COMMENTS:

JPM RO A1b 7

Performance Step 6:

Critical X Not Critical Difference Standard:

Calculates the difference 150 - actual temperature recorded; can record any of the following temperatures 52 °F to 53 °F.

SAT UNSAT N/A COMMENTS:

Performance Step 7:

Critical X Not Critical TIME (in hours) For FUEL POOL TO REACH Target Temperature

= hrs Standard:

Divides the difference by 0.99 and calculates a time to reach 150 °F of one of the following 52.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> to 53.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.

SAT UNSAT N/A COMMENTS:

Performance Step 8:

Critical X Not Critical Difference Standard:

Calculates the difference 200 - actual temperature recorded; can record any of the following temperatures 102 °F to 103 °F.

SAT UNSAT N/A COMMENTS:

JPM RO A1b 8

Performance Step 9:

Critical X Not Critical TIME (in hours) For FUEL POOL TO REACH Target Temperature

= hrs Standard:

Divides the difference by 0.99 and calculates a time to reach 200 °F of one of the following 103 hours0.00119 days <br />0.0286 hours <br />1.703042e-4 weeks <br />3.91915e-5 months <br /> to 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br />.

SAT UNSAT N/A COMMENTS:

END OF TASK STOP TIME

JPM RO A2 1

OPERATOR:________________________________

RO DATE:

JPM NUMBER:

RO A2 TASK NUMBER:

U-000-AD-18 TASK TITLE:

SRM Operability Surveillance K/A NUMBER: 2.2.44 K/A RATING: RO 4.2 TASK STANDARD: Complete of SRM Operability surveillance and determine if core alterations may commence.

LOCATION OF PERFORMANCE: Simulator REFERENCES/PROCEDURES NEEDED: 2-SR-3.3.1.2.4, Source Range Monitor System Count Rate and Signal to Noise Ratio Check VALIDATION TIME: 30 minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES NO RESULTS:

SATISFACTORY _____ UNSATISFACTORY_____

SIGNATURE: ____________________________ DATE: _____________

EXAMINER

INITIAL CONDITIONS: You are a Reactor Operator on Unit 2. Unit 2 is in Mode 5, initial core alterations will commence within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

INITIATING CUES: The Unit Supervisor directs you to complete 2-SR-3.3.1.2.4, Source Range Monitor System Count Rate and Signal to Noise Ratio Check.

JPM RO A2 3

Simulator INITIAL CONDITIONS: You are a Reactor Operator on Unit 2. Unit 2 is in Mode 5, initial core alterations will commence within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

INITIATING CUES: The Unit Supervisor directs you to complete 2-SR-3.3.1.2.4, Source Range Monitor System Count Rate and Signal to Noise Ratio Check.

JPM RO A2 4

START TIME Performance Step 1:

Critical Not Critical X 7.2 SRM Checks By Withdrawing SRM or FLC NOTES

1)

It is not necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

2)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

3)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field Just prior to lowering it into its new location.

7.2.1 SRM A Count Rate and Signal to Noise Ratio Check Steps:

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) A.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) A as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the SRM A position.

Standard:

Obtain permission is NA. Core Alterations are not in progress, bypasses SRM A.

SAT UNSAT N/A COMMENTS:

JPM RO A2 5

Performance Step 2:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM A (or FLC A). (N/A if portable neutron source is not used.)

[4]

  • RETRACT SRM A (or withdraw FLC A).

Standard:

Step 3 is NA, *Retracts SRM A fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 3:

Critical X Not Critical

[5]

RECORD SRM (or FLC) A count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM A count rate of.1 to.2 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 4:

Critical X Not Critical

[6]

REINSERT SRM A fully (or MOVE FLC A into desired location).

Standard:

Inserts SRM A fully SAT UNSAT N/A COMMENTS:

JPM RO A2 6

Performance Step 5:

Critical X Not Critical

[7]

RECORD SRM (or FLC) A count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM A count rate of 150 to 250 cps SAT UNSAT N/A COMMENTS:

Performance Step 6:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.1[7] - Reading from step 7.2.1[5]

Reading from step 7.2.1[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3 SAT UNSAT N/A COMMENTS:

Performance Step 7:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3 SAT UNSAT N/A COMMENTS:

JPM RO A2 7

Performance Step 8:

Critical Not Critical X

[10]

IF Step 7.2.1[3] was performed, THEN REQUEST the Refueling Floor SRO to perform the following: (Otherwise N/A)

[11]

UN-BYPASS SRM A (or FLC A) as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the mid (Neutral) position.

Standard:

Step 10 is NA, removes SRM A from bypass SAT UNSAT N/A COMMENTS:

Performance Step 9:

  • Critical X Not Critical

[12]

  • VERIFY that SRM A (or FLC A) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM A (or FLC A) has been un-bypassed. (N/A in case core alterations have been suspended.)

[14]

VERIFY SRM A is UNBYPASSED.

Standard:

Verifies SRM A has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

CUE:

Inform operator IV is complete

JPM RO A2 8

Performance Step 10:

Critical Not Critical X NOTES

1)

It is not necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

2)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

3)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field Just prior to lowering it into its new location.

7.2.2 SRM B Count Rate and Signal to Noise Ratio Check Steps:

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) B.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) B as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the SRM B position.

Standard:

Obtain permission is NA. Core Alterations are not in progress, bypasses SRM B.

SAT UNSAT N/A COMMENTS:

Performance Step 11:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM B (or FLC B). (N/A if portable neutron source is not used.)

[4]

  • RETRACT SRM B (or withdraw FLC B).

Standard:

Step 3 is NA, *Retracts SRM B fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

JPM RO A2 9

Performance Step 12:

Critical X Not Critical

[5]

RECORD SRM (or FLC) B count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM B count rate of.1 to.2 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 13:

Critical X Not Critical

[6]

REINSERT SRM B fully (or MOVE FLC B into desired location).

Standard:

Inserts SRM B fully.

SAT UNSAT N/A COMMENTS:

Performance Step 14:

Critical X Not Critical

[7]

RECORD SRM (or FLC) B count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM B count rate of 100 to 200 cps SAT UNSAT N/A COMMENTS:

JPM RO A2 10 Performance Step 15:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.2[7] - Reading from step 7.2.2[5]

Reading from step 7.2.2[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3 SAT UNSAT N/A COMMENTS:

Performance Step 16:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3 SAT UNSAT N/A COMMENTS:

JPM RO A2 11 Performance Step 17:

Critical Not Critical X

[10]

IF Step 7.2.2[3] was performed, THEN REQUEST the Refueling Floor SRO to perform the following: (Otherwise N/A)

[11]

UN-BYPASS SRM B (or FLC B) as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the mid (Neutral) position.

Standard:

Step 10 is NA, removes SRM B from bypass SAT UNSAT N/A COMMENTS:

Performance Step 18:

  • Critical X Not Critical

[12]

  • VERIFY that SRM B (or FLC B) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM B (or FLC B) has been un-bypassed. (N/A in case core alterations have been suspended.)

[14]

VERIFY SRM B is UNBYPASSED.

Standard:

Verifies SRM B has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

CUE:

Inform operator IV is complete.

JPM RO A2 12 Performance Step 19:

Critical Not Critical X NOTES

1)

It is not necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

2)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

3)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field Just prior to lowering it into its new location.

7.2.3 SRM C Count Rate and Signal to Noise Ratio Check Steps:

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) C.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) C as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the SRM C position.

Standard:

Obtain permission is NA Core Alterations are not in progress, bypasses SRM C SAT UNSAT N/A COMMENTS:

Performance Step 20:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM C (or FLC C). (N/A if portable neutron source is not used.)

[4]

  • RETRACT SRM C (or withdraw FLC C).

Standard:

Step 3 is NA, *Retracts SRM C fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

JPM RO A2 13 Performance Step 21:

Critical X Not Critical

[5]

RECORD SRM (or FLC) C count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM C count rate of.1 to.2 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 22:

Critical X Not Critical

[6]

REINSERT SRM C fully (or MOVE FLC C into desired location).

Standard:

Inserts SRM C fully SAT UNSAT N/A COMMENTS:

Performance Step 23:

Critical X Not Critical

[7]

RECORD SRM (or FLC) C count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM C count rate of 200 to 300 cps SAT UNSAT N/A COMMENTS:

JPM RO A2 14 Performance Step 24:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.3[7] - Reading from step 7.2.3[5]

Reading from step 7.2.3[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3.

SAT UNSAT N/A COMMENTS:

Performance Step 25:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3.

SAT UNSAT N/A COMMENTS:

JPM RO A2 15 Performance Step 26:

Critical Not Critical X

[10]

IF Step 7.2.3[3] was performed, THEN REQUEST the Refueling Floor SRO to perform the following: (Otherwise N/A)

[11]

UN-BYPASS SRM C (or FLC C) as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the mid (Neutral) position.

Standard:

Step 10 is NA, removes SRM C from bypass.

SAT UNSAT N/A COMMENTS:

Performance Step 27:

  • Critical X Not Critical

[12]

  • VERIFY that SRM C (or FLC C) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM C (or FLC C) has been un-bypassed. (N/A in case core alterations have been suspended.)

[14]

VERIFY SRM C is UNBYPASSED.

Standard:

Verifies SRM C has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

CUE:

Inform operator IV is complete.

JPM RO A2 16 Performance Step 28:

Critical Not Critical X NOTES

1)

It is not necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

2)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

3)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field Just prior to lowering it into its new location.

7.2.4 SRM D Count Rate and Signal to Noise Ratio Check Steps:

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) D.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) D as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the SRM D position.

Standard:

Obtain permission is NA Core Alterations are not in progress, bypasses SRM D SAT UNSAT N/A COMMENTS:

Performance Step 29:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM D (or FLC B). (N/A if portable neutron source is not used.)

[4]

  • RETRACT SRM D (or withdraw FLC D).

Standard:

Step 3 is NA, *Retracts SRM D fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

JPM RO A2 17 Performance Step 30:

Critical X Not Critical

[5]

RECORD SRM (or FLC) D count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM D count rate of.1 to.2 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 31:

Critical X Not Critical

[6]

REINSERT SRM D fully (or MOVE FLC D into desired location).

Standard:

Inserts SRM D fully SAT UNSAT N/A COMMENTS:

Performance Step 32:

Critical X Not Critical

[7]

RECORD SRM (or FLC) D count rate from indicator (Panel 2-9-5):

_______ cps Standard:

Records SRM D count rate of 100 to 200 cps SAT UNSAT N/A COMMENTS:

JPM RO A2 18 Performance Step 33:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.4[7] - Reading from step 7.2.4[5]

Reading from step 7.2.4[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3.

SAT UNSAT N/A COMMENTS:

Performance Step 34:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3.

SAT UNSAT N/A COMMENTS:

JPM RO A2 19 Performance Step 35:

Critical Not Critical X

[10]

IF Step 7.2.2[3] was performed, THEN REQUEST the Refueling Floor SRO to perform the following: (Otherwise N/A)

[11]

UN-BYPASS SRM D (or FLC D) as follows PLACE SRM BYPASS, 2-HS-92-7A/S3 in the mid (Neutral) position.

Standard:

Step 10 is NA, removes SRM D from bypass.

SAT UNSAT N/A COMMENTS:

Performance Step 36:

  • Critical X Not Critical

[12]

  • VERIFY that SRM D (or FLC D) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM D (or FLC D) has been un-bypassed. (N/A in case core alterations have been suspended.)

[14]

VERIFY SRM D is UNBYPASSED.

Standard:

Verifies SRM D has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

CUE:

Inform operator IV is complete.

JPM RO A2 20 Performance Step 37:

Critical X Not Critical Standard:

Quad A Quad B Quad C Quad D yes yes yes yes

> 3 cps yes yes yes yes

> 3:1 signal to noise yes yes yes yes quadrant fueled yes yes yes yes SAT UNSAT N/A COMMENTS:

JPM RO A2 21 Performance Step 38:

Critical X Not Critical

[2]

VERIFY an operable SRM detector is located in each core quadrant in which core alterations are being performed (OR planned within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />)

AND an adjacent core quadrant. CHECK MARK the appropriate operable SRMs for each core Quad:

IF Quad A, THEN SRM A and either SRM B or SRM D _____(AC)

IF Quad B, THEN SRM B and either SRM A or SRM C _____(AC)

IF Quad C, THEN SRM C and either SRM B or SRM D _____(AC)

IF Quad D, THEN SRM D and either SRM A or SRM C _____(AC)

Standard:

Checks all blocks and initials in each acceptance criteria spot that acceptance criteria IS MET for all 4 quadrants.

SAT UNSAT N/A COMMENTS:

END OF TASK STOP TIME CUE: Another operator will complete.

JPM RO A2 1

OPERATOR:________________________________

RO DATE:

JPM NUMBER:

RO A2 TASK NUMBER:

U-000-AD-18 TASK TITLE:

SRM Operability Surveillance K/A NUMBER: 2.2.44 K/A RATING: RO 4.2 TASK STANDARD: Complete of SRM Operability surveillance and determine if core alterations may commence.

LOCATION OF PERFORMANCE: Simulator REFERENCES/PROCEDURES NEEDED: 3-SR-3.3.1.2.4, Source Range Monitor System Count Rate and Signal to Noise Ratio Check VALIDATION TIME: 30 minutes PERFORMANCE TIME:

COMMENTS:

Additional comment sheets attached? YES NO RESULTS:

SATISFACTORY _____ UNSATISFACTORY_____

SIGNATURE: ____________________________ DATE: _____________

EXAMINER

INITIAL CONDITIONS: You are a Reactor Operator on Unit 3. Unit 3 is in Mode 5, initial core alterations will commence within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

INITIATING CUES: The Unit Supervisor directs you to complete 3-SR-3.3.1.2.4 Source Range Monitor System Count Rate and Signal to Noise Ratio Check.

JPM RO A2 3

Simulator INITIAL CONDITIONS: You are a Reactor Operator on Unit 3. Unit 3 is in Mode 5, initial core alterations will commence within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

INITIATING CUES: The Unit Supervisor directs you to complete 3-SR-3.3.1.2.4 Source Range Monitor System Count Rate and Signal to Noise Ratio Check.

JPM RO A2 4

START TIME Performance Step 1:

Critical Not Critical X 7.2 SRM Checks Utilizing Moving of the Detector or Neutron Source 7.2.1 SRM A Count Rate and Signal to Noise Ratio Check Determination

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) A.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) A.

Standard:

Obtain permission is NA Core Alterations are not in progress, bypasses SRM A SAT UNSAT N/A COMMENTS:

Performance Step 2:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM A (or FLC A). (Otherwise N/A)

NOTE It is NOT necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

[4]

  • RETRACT SRM A (or withdraw FLC A).

Standard:

Step 3 is NA, *Retracts SRM A fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

JPM RO A2 5

Performance Step 3:

Critical X Not Critical NOTES

1)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

2)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field just prior to lowering it into its new location.

[5]

RECORD SRM (or FLC) A count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM A count rate of 0.1 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 4:

Critical X Not Critical

[6]

REINSERT SRM A fully (or MOVE FLC A into desired location).

Standard:

Inserts SRM A fully SAT UNSAT N/A COMMENTS:

JPM RO A2 6

Performance Step 5:

Critical X Not Critical

[7]

RECORD SRM (or FLC) A count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM A count rate of 100 to 200 cps SAT UNSAT N/A COMMENTS:

Performance Step 6:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.1[7] - Reading from step 7.2.1[5]

Reading from step 7.2.1[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3 SAT UNSAT N/A COMMENTS:

Performance Step 7:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3 SAT UNSAT N/A COMMENTS:

JPM RO A2 7

Performance Step 8:

Critical Not Critical X

[10]

IF applicable, THEN REQUEST the Refueling Floor SRO to REMOVE neutron source from Step 7.2.1[3] and PLACE it adjacent to SRM (or FLC) B or PLACE as directed by the Reactor Engineer.

[11]

UN-BYPASS SRM A (or FLC A).

Standard:

Step 10 is NA, removes SRM A from bypass SAT UNSAT N/A COMMENTS:

Performance Step 9:

  • Critical X Not Critical

[12]

  • VERIFY that SRM A (or FLC A) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM A (or FLC A) has been un-bypassed. (N/A in case core alterations have been suspended.)

Standard:

Verifies SRM A has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

JPM RO A2 8

Performance Step 10:

Critical Not Critical X 7.2.2 SRM B Count Rate and Signal to Noise Ratio Determination

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) B.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) B.

Standard:

Obtain permission is NA Core Alterations are not in progress, bypasses SRM B SAT UNSAT N/A COMMENTS:

Performance Step 11:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM B (or FLC B). (Otherwise N/A)

NOTE It is NOT necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

[4]

  • RETRACT SRM B (or withdraw FLC B).

Standard:

Step 3 is NA, *Retracts SRM B fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

JPM RO A2 9

Performance Step 12:

Critical X Not Critical NOTES

1)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

2)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field just prior to lowering it into its new location.

[5]

RECORD SRM (or FLC) B count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM B count rate of.1 to.2 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 13:

Critical X Not Critical

[6]

REINSERT SRM B fully (or MOVE FLC B into desired location).

Standard:

Inserts SRM B fully SAT UNSAT N/A COMMENTS:

JPM RO A2 10 Performance Step 14:

Critical X Not Critical

[7]

RECORD SRM (or FLC) B count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM B count rate of 100 to 200 cps SAT UNSAT N/A COMMENTS:

Performance Step 15:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.2[7] - Reading from step 7.2.2[5]

Reading from step 7.2.2[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3 SAT UNSAT N/A COMMENTS:

Performance Step 16:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3 SAT UNSAT N/A COMMENTS:

JPM RO A2 11 Performance Step 17:

Critical Not Critical X

[10]

IF applicable, THEN REQUEST the Refueling Floor SRO to REMOVE neutron source from Step 7.2.3[3] and PLACE it adjacent to SRM (or FLC) D or PLACE as directed by the Reactor Engineer.

[11]

UN-BYPASS SRM B (or FLC B).

Standard:

Step 10 is NA, removes SRM B from bypass SAT UNSAT N/A COMMENTS:

Performance Step 18:

  • Critical X Not Critical

[12]

  • VERIFY that SRM B (or FLC B) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM B (or FLC B) has been un-bypassed. (N/A in case core alterations have been suspended.)

Standard:

Verifies SRM B has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

JPM RO A2 12 Performance Step 19:

Critical Not Critical X 7.2.3 SRM C Count Rate and Signal to Noise Ratio Determination

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) C.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) C.

Standard:

Obtain permission is NA Core Alterations are not in progress, bypasses SRM C SAT UNSAT N/A COMMENTS:

Performance Step 20:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM C (or FLC C). (Otherwise N/A)

NOTE It is NOT necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

[4]

  • RETRACT SRM C (or withdraw FLC C).

Standard:

Step 3 is NA, *Retracts SRM C fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

JPM RO A2 13 Performance Step 21:

Critical X Not Critical NOTES

1)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

2)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field just prior to lowering it into its new location.

[5]

RECORD SRM (or FLC) C count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM C count rate of.1 to.2 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 22:

Critical X Not Critical

[6]

REINSERT SRM C fully (or MOVE FLC C into desired location).

Standard:

Inserts SRM C fully SAT UNSAT N/A COMMENTS:

JPM RO A2 14 Performance Step 23:

Critical X Not Critical

[7]

RECORD SRM (or FLC) C count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM C count rate of 100 to 200 cps SAT UNSAT N/A COMMENTS:

Performance Step 24:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.3[7] - Reading from step 7.2.3[5]

Reading from step 7.2.3[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3 SAT UNSAT N/A COMMENTS:

Performance Step 25:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3 SAT UNSAT N/A COMMENTS:

JPM RO A2 15 Performance Step 26:

Critical Not Critical X

[10]

IF applicable, THEN REQUEST the Refueling Floor SRO to REMOVE neutron source from Step 7.2.3[3] and PLACE it adjacent to SRM (or FLC) D or PLACE as directed by the Reactor Engineer.

[11]

UN-BYPASS SRM C (or FLC C).

Standard:

Step 10 is NA, removes SRM C from bypass SAT UNSAT N/A COMMENTS:

Performance Step 27:

  • Critical X Not Critical

[12]

  • VERIFY that SRM C (or FLC C) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM C (or FLC C) has been un-bypassed. (N/A in case core alterations have been suspended.)

Standard:

Verifies SRM C has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

JPM RO A2 16 Performance Step 28:

Critical Not Critical X 7.2.4 SRM D Count Rate and Signal to Noise Ratio Determination

[1]

OBTAIN permission from the Refuel Floor SRO to bypass SRM (or FLC) D.

(N/A in case core alterations have been suspended.)

[2]

BYPASS SRM (or FLC) D.

Standard:

Obtain permission is NA Core Alterations are not in progress, bypasses SRM D SAT UNSAT N/A COMMENTS:

Performance Step 29:

  • Critical X Not Critical

[3]

If applicable, request the Refueling Floor SRO to PLACE portable neutron source adjacent to SRM D (or FLC B). (Otherwise N/A)

NOTE It is NOT necessary to fully retract the SRMs in the event that the required change in SRM count rate (< 25% of original count rate) is observed before the SRM is fully retracted.

[4]

  • RETRACT SRM D (or withdraw FLC D).

Standard:

Step 3 is NA, *Retracts SRM D fully or to a count rate of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

JPM RO A2 17 Performance Step 30:

Critical X Not Critical NOTES

1)

In the event that the SRM indicator is downscale, record the lowest scale reading of 0.1 cps.

2)

In the event that the response check is being performed during a change in FLC location, record initial count rate while FLC is out of the neutron field just prior to lowering it into its new location.

[5]

RECORD SRM (or FLC) D count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM D count rate of.1 cps or a value of less than 25% of initial reading SAT UNSAT N/A COMMENTS:

Performance Step 31:

Critical X Not Critical

[6]

REINSERT SRM D fully (or MOVE FLC D into desired location).

Standard:

Inserts SRM D fully SAT UNSAT N/A COMMENTS:

JPM RO A2 18 Performance Step 32:

Critical X Not Critical

[7]

RECORD SRM (or FLC) D count rate from indicator (Panel 3-9-5):

_______ cps Standard:

Records SRM D count rate of 100 to 200 cps SAT UNSAT N/A COMMENTS:

Performance Step 33:

Critical X Not Critical

[8]

COMPUTE the signal to noise ratio as follows and RECORD results below:

Reading from step 7.2.4[7] - Reading from step 7.2.4[5]

Reading from step 7.2.4[5]

The signal to noise ratio is Standard:

Computes Signal to noise ratio of greater than 3 SAT UNSAT N/A COMMENTS:

Performance Step 34:

Critical Not Critical X

[9]

VERIFY signal to noise ratio is > 3.

Standard:

Verifies signal to noise ratio greater than 3 SAT UNSAT N/A COMMENTS:

JPM RO A2 19 Performance Step 35:

Critical Not Critical X

[10]

IF applicable, THEN REQUEST the Refueling Floor SRO to REMOVE neutron source from Step 7.2.4[3] and PLACE as directed by the Reactor Engineer.

[11]

UN-BYPASS SRM D (or FLC D).

Standard:

Step 10 is NA, removes SRM D from bypass SAT UNSAT N/A COMMENTS:

Performance Step 36:

  • Critical X Not Critical

[12]

  • VERIFY that SRM D (or FLC D) has 3 cps, or VERIFY that 4 fuel assemblies are adjacent to the SRM and no other fuel assemblies in the associated core quadrant.

[13]

NOTIFY the Refuel Floor SRO that SRM D (or FLC D) has been un-bypassed. (N/A in case core alterations have been suspended.)

Standard:

Verifies SRM D has greater than 3 cps, step 13 is NA.

SAT UNSAT N/A COMMENTS:

JPM RO A2 20 Performance Step 37:

Critical X Not Critical Standard:

Quad A Quad B Quad C Quad D yes yes yes yes

> 3 cps yes yes yes yes

> 3:1 signal to noise yes yes yes yes quadrant fueled yes yes yes yes SAT UNSAT N/A COMMENTS:

JPM RO A2 21 Performance Step 38:

Critical X Not Critical NOTE SRM Operability is established when the count rate is 3 cps with a signal-to-noise ratio 3:1 (NOT required whenever 4 fuel assemblies adjacent to the SRM and no other fuel assemblies in the associated core quadrant) Step 7.4[2] may be N/Aed for each core quad where no core alterations are being performed and none expected within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

[2]

VERIFY an operable SRM detector is located in each core quadrant in which core alterations are being performed (OR planned within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />)

AND an adjacent core quadrant. CHECK MARK the appropriate operable SRMs for each core Quad:

IF Quad A, THEN SRM A and either SRM B or SRM D _____(AC)

IF Quad B, THEN SRM B and either SRM A or SRM C _____(AC)

IF Quad C, THEN SRM C and either SRM B or SRM D _____(AC)

IF Quad D, THEN SRM D and either SRM A or SRM C _____(AC)

Standard:

Checks all blocks and initials in each acceptance criteria spot that acceptance criteria IS MET for all 4 quadrants.

SAT UNSAT N/A COMMENTS:

END OF TASK STOP TIME CUE: Another operator will complete

JPM A3 1

OPERATOR: ________________________________

RO SRO DATE:

JPM NUMBER:

548 TASK NUMBER:

Radiation Control TASK TITLE:

Locked High Radiation Entry K/A NUMBER: 2.3.12 K/A RATING: RO 3.2 TASK STANDARD: Determine dress out requirements and estimate dose to verify within RWP and quarterly limits. Determines exceeds quarterly administrative dose limit of 1000 mRem and determines that the MG dose alarm will sound for a dose of greater than 200 mRem.

LOCATION OF PERFORMANCE: Class Room REFERENCES/PROCEDURES NEEDED: Handout RWP and Survey Map, NPG-SPP 5.1 VALIDATION TIME: 15 minutes PERFORMANCE TIME:

COMMENTS: __________________________________________________________

Additional comment sheets attached? YES ___ NO ___

RESULTS:

SATISFACTORY ____

UNSATISFACTORY ____

SIGNATURE: __________________________

DATE: __________

EXAMINER

INITIAL CONDITIONS: You are a Browns Ferry employee who has obtained an accumulative yearly dose of 750 mrem.

The job will require you to vent the RWCU Regenerative Hx and to manually close the 3-FCV-69-2 valve and place a mechanical restraining device on the valve. The RWCU Regenerative Hx will be vented from the scaffold at the south end of the Hx's (a scaffold has been erected to be used for venting - cannot leave scaffold while venting is in progress), and will require 35 minutes for venting. Then proceed to 3-FCV-69-2 valve to manually close and install the mechanical restraining device, it should require 25 minutes to close the valve and another 25 minutes to install the mechanical restraining device. Assume the 30cm reading will be the whole body dose received at each location. Assume a total travel dose of 25 mrem will be received.

INITIATING CUES: Given the survey map and RWP, determine the following:

  • Dress-out requirements for entry to perform your assigned task
  • Whether you can complete the assigned task in the area without exceeding your TVA administrative dose limit
  • Whether you can complete the assigned task in the area without exceeding the RWP dose entry limits both rate and total dose, i.e. will you receive an MG alarm (Electronic Dosimeter).

JPM A3 3

Class Room INITIAL CONDITIONS: You are a Browns Ferry employee who has obtained an accumulative yearly dose of 750 mrem.

The job will require you to vent the RWCU Regenerative Hx and to manually close the 3-FCV-69-2 valve and place a mechanical restraining device on the valve. The RWCU Regenerative Hx will be vented from the scaffold at the south end of the Hx's (a scaffold has been erected to be used for venting - cannot leave scaffold while venting is in progress), and will require 35 minutes for venting. Then proceed to 3-FCV-69-2 valve to manually close and install the mechanical restraining device, it should require 25 minutes to close the valve and another 25 minutes to install the mechanical restraining device. Assume the 30cm reading will be the whole body dose received at each location. Assume a total travel dose of 25 mrem will be received.

INITIATING CUES: Given the survey map and RWP, determine the following:

  • Dress-out requirements for entry to perform your assigned task
  • Whether you can complete the assigned task in the area without exceeding your TVA administrative dose limit
  • Whether you can complete the assigned task in the area without exceeding the RWP dose entry limits both rate and total dose, i.e. will you receive an MG alarm (Electronic Dosimeter).

JPM A3 4

START TIME Performance Step 1:

Critical X Not Critical Determines Dress Out requirements Standard:

Shoe covers - one pair, Coveralls - one pair, Face Shield, Gloves - rubber - two pair, cloth inserts, Booties - plastic - 2 pair, Rain suit, and Hood SAT UNSAT N/A COMMENTS:

Performance Step 2:

Critical X Not Critical Calculates RWCU HX venting dose.

Standard:

35 minutes in a 250 mrem/hr area = 145 to 146 mrem SAT UNSAT N/A COMMENTS:

Performance Step 3:

Critical X Not Critical Calculates 69-2 valve work dose Standard:

50 minutes in a 100 mrem/hr area = 83 to 84 mrem SAT UNSAT N/A COMMENTS:

JPM A3 5

Performance Step 4:

Critical X Not Critical Calculates total dose received Standard:

25 mrem travel + 146 mrem venting + 83 mrem 69-2 = 254 mrem SAT UNSAT N/A COMMENTS:

Performance Step 5:

Critical X Not Critical Calculates total dose for quarter Standard:

750 mrem + 254 mrem = 1004 mrem SAT UNSAT N/A COMMENTS:

Performance Step 6:

  • Critical X Not Critical Verifies RWP MG Setpoints Standard:

MG setpoints: for Dose Rate alarm of 500 mrem/hr will not be exceeded and *Dose alarm of 200 mrem will be exceeded.

SAT UNSAT N/A COMMENTS:

JPM A3 6

Performance Step 7:

Critical X Not Critical Verifies dose limits for quarter and RWP Standard:

Verifies will have a total dose of greater than 1000 mrem which is above the TVA administrative limit.

SAT UNSAT N/A COMMENTS:

END OF TASK STOP TIME

BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY GENERAL DESCRIPTION Status: Active Start Date: 01-Jan-This year End Date: 01-Jan-Next year Type: SPECIFIC MAP ID: Outage: Y Name:

Task: ROUTINE PLANT MAINTENANCE PSE: N HP CONTINUOUS Authorization Type: INDIVIDUAL ALARA Review Number: 0A-0010 Primary Work Doc:

Person-mrem Estimate: 1904 Person-Hrs Estimate: 1082 Dose Alarm: 200 Dose Rate Alarm: 500 DAC-Hrs Tracked: N Work Area

Description:

RWCU HX Room Unit 3 DESCRIPTION OF WORK TO BE PERFORMED Unit 3 Maintenance on RWCU (69) Systems (LHRA VARIOUS DRESS) 200 / 500 ANTI-CONTAMINATION CLOTHING REQUIREMENTS 1 LAB COAT 1,2 BOOTIES, CLOTH, ONE PAIR 1,2 GLOVES, RUBBER, ONE PAIR 1,2,3 CLOTH INSERTS 1,2,3 SHOE COVERS, ONE PAIR 1,2,3 MODESTY CLOTHING 1,2,3 NO PERSONAL OUTER CLOTHING 1,2,3 SURGEON'S CAP 2,3 COVERALLS, ONE PAIR 3 BOOTIES, PLASTIC, TWO PAIR 3 FACE SHIELD 3 RAIN SUIT 3 GLOVES, RUBBER, TWO PAIR 3,4 HOOD DOSIMETRY REQUIREMENTS ELECTRONIC DOSIMETER TLD BRIEFING REQUIREMENTS PRE-JOB BRIEFING WORK STEPS 1 MANAGEMENT / WO WALKDOWN 2 3-CI-412 3 OPS VALVE LINEUP OI-69 & HX VENTING 4 07-712928-000 5 06-722560-000 6 06-727133-000 7 06-722556-000 8 06-722559-000 9 06-718308-002 10 06-722558-000 BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training

Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY WORKER INSTRUCTIONS 1 DRESSOUT CODE APPLICATIONS

1) FLOOR LEVEL INSP, LOW TO MODERATE CONTAMINATION.
2) MINOR MAINTENANCE, NO PRIMARY SYSTEM BREACH.
3) PRIMARY SYSTEM BREACH, HEAT EXCHANGER VENTING.
4) ANY WORK ABOVE FLOOR LEVEL REQUIRES SAFETY BELT W/ LIFELINE.
5) REQUIRED TO WEAR HEADGEAR OTHER THAN PERSONAL HARDHAT.

2 MONITOR YOUR ED (DAD) FREQUENTLY, EXIT THE AREA PRIOR TO REACHING THE DOSE ALARM SET POINT OR UPON RECEIVING ANY UNEXPECTED ALARMS.

3 DO NOT EXCEED 200 mrem PER ENTRY OR DOSE MARGIN (RAD-REMAINING ALLOWABLE DOSE).

4 REMOTE MONITORING, PEA, OR SIMILAR DEVICE REQUIRED.

5 ED (DAD) TO BE BAGGED (WRAPPED) AND WORN OUTSIDE OF C-ZONE CLOTHING.

6 REVIEW PLANNED WORK OR INSPECTIONS WITH RAD PROTECTION PRIOR TO ENTRY.

7 UTILIZE TIME, DISTANCE, AND SHIELDING ALARA PRINCIPLES.

8 REVIEW APPROPRIATE SURVEY DATA PRIOR TO ENTRY. NOTE AND AVOID POSTED HOT SPOTS. LOCATE AND UTILIZE LOW DOSE WAITING AREAS.

9 RADWORKER SHALL ADHERE TO ANY SPECIAL INSTRUCTIONS (APR, ETC) ON WHICH HE/SHE HAS BEEN BRIEFED BY RAD PROTECTION.

10 NOTIFY RADCON PRIOR TO ANY SYSTEM BREACH.

11 RAD PROTECTION COVERAGE MAY BE PROVIDED FROM OUTSIDE THE C-ZONE.

12 SECURE ALL HOSES, ELECTRICAL CORDS, WELDING LEADS AND OTHER SERVICES ENTERING THE C-ZONE AT THE C-ZONE BOUNDRY AND NOTIFY RAD PROTECTION.

13 NOTIFY RAD PROTECTION OF ANY UNUSUAL RADIOLOGICAL CONDITIONS (FOR EXAMPLE: WATER, LEAKS, RADIATION MONITOR ALARMS).

14 RAD PROTECTION PERMISSION REQUIRED PRIOR TO WELDING, GRINDING, BUFFING OR OTHER SURFACE DISTURBING ACTIVITIES.

APPROVAL Prepaired by: TJFRANK Approved by: MJHAZEL Final Approval: JWSMITH3 End of RWP